Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 145
Filtrar
Más filtros

Bases de datos
País/Región como asunto
Tipo del documento
Intervalo de año de publicación
1.
Methods ; 212: 12-20, 2023 04.
Artículo en Inglés | MEDLINE | ID: mdl-36858137

RESUMEN

Gut microbiota plays a crucial role in modulating pig development and health, and gut microbiota characteristics are associated with differences in feed efficiency. To answer open questions in feed efficiency analysis, biologists seek to retrieve information across multiple heterogeneous data sources. However, this is error-prone and time-consuming work since the queries can involve a sequence of multiple sub-queries over several databases. We present an implementation of an ontology-based Swine Gut Microbiota Federated Query Platform (SGMFQP) that provides a convenient, automated, and efficient query service about swine feeding and gut microbiota. The system is constructed based on a domain-specific Swine Gut Microbiota Ontology (SGMO), which facilitates the construction of queries independent of the actual organization of the data in the individual sources. This process is supported by a template-based query interface. A Datalog+-based federated query engine transforms the queries into sub-queries tailored for each individual data source, and an automated workflow orchestration mechanism executes the queries in each source database and consolidates the results. The efficiency of the system is demonstrated on several swine feeding scenarios.


Asunto(s)
Microbioma Gastrointestinal , Interfaz Usuario-Computador , Animales , Porcinos , Bases de Datos Factuales , Fuentes de Información , Semántica
2.
Klin Monbl Augenheilkd ; 241(6): 781-798, 2024 Jun.
Artículo en Alemán | MEDLINE | ID: mdl-38788737

RESUMEN

Corneal transplantation can be divided into two groups: penetrating and lamellar keratoplasty. Newer minimally invasive procedures have emerged over the years, to improve the visual outcome and reduce complications. This article summarizes the different procedures, their indications and complications, and outlines the pre-, peri- and postoperative management in a clinical setting.Corneal transplantation is the most commonly performed transplantation of donor tissue in modern medicine. In the last years a shift away from penetrating keratoplasty (PK) towards minimally invasive lamellar operative techniques, associated with less complications, can be observed. The Descemet membrane endothelial keratoplasty (DMEK) is used to treat endothelial corneal pathologies and has overtaken the PK to become the most commonly performed form of keratoplasty. Preparation and identification of possible risk-factors are essential preoperative steps to reduce peri- and postoperative complications of keratoplasties. If corneal graft rejection occurs, early and maximum therapy is crucial for graft survival. Laser-assisted techniques offer different advantages in lamellar and penetrating keratoplasty but are not very cost-efficient.


Asunto(s)
Trasplante de Córnea , Humanos , Trasplante de Córnea/métodos , Atención Perioperativa/métodos , Enfermedades de la Córnea/cirugía , Complicaciones Posoperatorias/prevención & control , Complicaciones Posoperatorias/etiología , Procedimientos Quirúrgicos Mínimamente Invasivos/métodos , Queratoplastia Penetrante/métodos
3.
Transfusion ; 63(8): 1546-1553, 2023 08.
Artículo en Inglés | MEDLINE | ID: mdl-37422880

RESUMEN

BACKGROUND: Extracorporeal photopheresis (ECP) treatment, mostly based on apheresis technology, is used for immunomodulation in various diseases such as cutaneous T-cell lymphoma, graft versus host disease and other (auto)immune disorders. The aim of this study was to collect high cell counts and purity in shorter procedure times using an ECP off-line system with an increased collection flow rate of 2 mL/min to a target volume of 200 mL buffy coat. STUDY DESIGN AND METHODS: In this prospective study, data of routinely performed off-line photopheresis treatments were collected and analyzed at the Central Institute for Blood Transfusion & Department of Immunology (ZIB) of the Tirol Kliniken, to assess absolute cell counts and procedure times and to calculate collection efficiencies (CE2). RESULTS: A total of 22 patients participated in this study. The processed blood volume was 4312 mL, the collection time 120 min, overall procedure time 157 min and the absolute cell counts of treated white blood cells (WBC) and mononuclear cells (MNC) were 5.0 and 4.3 × 109 respectively (median values). The calculated CE2 for WBC and MNC was 21.1% and 58.5%, the proportion of treated MNCs of the total number of MNCs present was 55.0%. CONCLUSION: The data presented in this study show high therapeutically effective cell counts collected with a high MNC purity within a shorter overall collection/procedure time due to an increased collection flow rate.


Asunto(s)
Eliminación de Componentes Sanguíneos , Enfermedad Injerto contra Huésped , Fotoféresis , Neoplasias Cutáneas , Humanos , Fotoféresis/métodos , Estudios Prospectivos , Leucocitos , Enfermedad Injerto contra Huésped/terapia
4.
Int J Mol Sci ; 24(5)2023 Feb 27.
Artículo en Inglés | MEDLINE | ID: mdl-36902019

RESUMEN

The aim of this study was to evaluate the long-time results of highly concentrated autologous platelet-rich plasma (PRP) used as an adjunct in lamellar macular hole (LMH) surgery. Nineteen eyes of nineteen patients with progressive LMH were enrolled in this interventional case series, on which 23/25-gauge pars plana vitrectomy was performed and 0.1 mL of highly concentrated autologous platelet-rich plasma was applied under air tamponade. Posterior vitreous detachment was induced, and the peeling of tractive epiretinal membranes, whenever present, was performed. In cases of phakic lens status, combined surgery was carried out. Postoperatively, all patients were instructed to remain in a supine position for the first two postoperative hours. Best-corrected visual acuity (BCVA) testing, microperimetry, and spectral domain optical coherence tomography (SD-OCT) were carried out preoperatively and at minimum 6 months (in median 12 months) postoperatively. Foveal configuration was postoperatively restored in 19 of 19 patients. Two patients who had not undergone ILM peeling showed a recurring defect at 6-month follow-up. Best-corrected visual acuity improved significantly from 0.29 ± 0.08 to 0.14 ± 0.13 logMAR (p = 0.028, Wilcoxon signed-rank test). Microperimetry remained unchanged (23.38 ± 2.53 preoperatively; 23.0 ± 2.49 dB postoperatively; p = 0.67). No patients experienced vision loss after surgery, and no significant intra- or postoperative complications were observed. Using PRP as an adjunct in macular hole surgery significantly improves morphological and functional outcomes. Additionally, it might be an effective prophylaxis to further progression and also the formation of a secondary full-thickness macular hole. The results of this study might contribute to a paradigm shift in macular hole surgery towards early intervention.


Asunto(s)
Membrana Epirretinal , Perforaciones de la Retina , Humanos , Perforaciones de la Retina/complicaciones , Perforaciones de la Retina/cirugía , Recurrencia Local de Neoplasia/cirugía , Fóvea Central , Membrana Epirretinal/complicaciones , Membrana Epirretinal/cirugía , Vitrectomía/métodos , Tomografía de Coherencia Óptica/métodos , Estudios Retrospectivos
5.
Klin Monbl Augenheilkd ; 240(3): 332-350, 2023 Mar.
Artículo en Alemán | MEDLINE | ID: mdl-36827995

RESUMEN

BACKGROUND: Modern preoperative diagnostics as well as current surgical techniques allow cataract and refractive surgery to deliver precise refractive results.Occasionally, unsatisfactory refractive and visual results occur despite all the care taken. In these cases, subsequent improvement is required to achieve the best final visual outcome. This article shows the therapeutic options for the treatment of residual refractive errors after lens and corneal refractive surgery. KEY MESSAGES: The causes of postoperative refractive errors after refractive laser- or lens-based procedures are very diverse and require extensive workup of the cause as well as an individual solution to achieve the desired result. Before any further surgical intervention, specific complications of the primary procedure as well as concomitant ocular diseases must be excluded or treated. The appropriate enhancement after keratorefractive surgery depends primarily on the type of primary surgery, residual stromal thickness, possible complications from the initial surgery, and the patient's personal preference. For enhancements using surface treatments, such as PRK, the use of mitomycin C is recommended for prophylaxis of haze formation. After lens surgery, for low-grade postoperative refractive errors (spherical and astigmatic), keratorefractive enhancements provide the most accurate results. For higher refractive errors, lens-based procedures can be used, with add-on IOLs being safer and more precise compared with one IOL exchange. Low astigmatisms can be successfully treated with LRI or keratorefractive surgery, but higher astigmatisms should be corrected with an IOL exchange in the early postoperative period and with an add-on IOL in the later postoperative period. IOL explantations should be performed very cautiously, especially in cases of pronounced capsular fibrosis, previous posterior capsulotomy, and existing weakness of the zonular apparatus.


Asunto(s)
Astigmatismo , Cristalino , Lentes Intraoculares , Errores de Refracción , Procedimientos Quirúrgicos Refractivos , Humanos , Córnea/cirugía , Errores de Refracción/diagnóstico , Errores de Refracción/terapia , Refracción Ocular , Astigmatismo/cirugía
6.
J Clin Apher ; 37(4): 332-339, 2022 Aug.
Artículo en Inglés | MEDLINE | ID: mdl-35225372

RESUMEN

BACKGROUND: Extracorporeal photopheresis (ECP) is a blood-based therapeutic procedure increasingly used for modulation of immune dysregulation in various underlying disease settings. The aim of this study was to compare the procedure times and blood collection efficiencies between the two approaches currently utilized in European centers: the integrated versus the multistep nonintegrated procedures. METHODS: A retrospective data analysis was conducted, comparing treatment data from patients who received ECP therapy at the Central Institute for Blood Transfusion & Department of Immunology (ZIB) of the Tirol Kliniken GmbH, where the integrated and multistep nonintegrated procedures are routinely used in an approximated setup. RESULTS: During the observation period, a total of 15 patients who were treated with alternating systems on 2 consecutive days were identified. This allowed treatment pair comparisons with minimal interpatient variabilities, similar to a cross-over design even though analyzed retrospectively. Total average procedure times with the integrated system were 99.3 vs 122.0 minutes with the multistep nonintegrated procedures, respectively. Significant differences were observed for all steps of the ECP procedure: (a) time for buffy coat collection, 66.5 vs 74.7; (b) handling/transfer, 2.8 vs 18.7; (c) irradiation, 20.3 vs 11.7; and (d) reinfusion/handling time, 9.6 vs 16.3 minutes. The calculated collection throughput was 7.79 mL/min for the integrated and 7.84 mL/min for the multistep nonintegrated procedures, and with a white blood cell (WBC) collection efficiency of 34.2% and 21.0%, respectively. CONCLUSION: The data presented in this study show a significant shorter overall procedure time and higher WBC collection efficiency for the integrated ECP system.


Asunto(s)
Enfermedad Injerto contra Huésped , Fotoféresis , Estudios Cruzados , Enfermedad Injerto contra Huésped/terapia , Humanos , Leucocitos , Fotoféresis/métodos , Estudios Retrospectivos
7.
Klin Monbl Augenheilkd ; 239(11): 1354-1360, 2022 Nov.
Artículo en Inglés, Alemán | MEDLINE | ID: mdl-35790199

RESUMEN

With an estimated incidence of 0.011%, the SMILE procedure seems to have the lowest risk of postoperative keratectasia among contemporary keratorefractive procedures. Nevertheless, due to the novelty of the procedure as well as the lack of data, no clear superiority over femto-LASIK or PRK can be stated at this time. In this respect, application of the identical tomographic screening criteria previously developed for excimer-based procedures is of paramount importance to minimize the risk of corneal ectasia. As an adjunct to conventional corneal tomography, newer imaging modalities such as OCT-based epithelial mapping should be used for preoperative screening before keratorefractive surgery. Corneal crosslinking is an established treatment modality for post-SMILE keratectasia, which promises high success rates especially in early stages. The present case report illustrates these diagnostic and therapeutic considerations.


Asunto(s)
Colágeno , Córnea , Enfermedades de la Córnea , Miopía , Procedimientos Quirúrgicos Refractivos , Humanos , Colágeno/metabolismo , Córnea/diagnóstico por imagen , Córnea/metabolismo , Córnea/cirugía , Enfermedades de la Córnea/etiología , Enfermedades de la Córnea/metabolismo , Enfermedades de la Córnea/terapia , Sustancia Propia/cirugía , Dilatación Patológica , Queratomileusis por Láser In Situ/efectos adversos , Queratomileusis por Láser In Situ/métodos , Láseres de Excímeros/uso terapéutico , Miopía/diagnóstico por imagen , Miopía/cirugía , Procedimientos Quirúrgicos Refractivos/efectos adversos , Procedimientos Quirúrgicos Refractivos/métodos
8.
Clin Chem Lab Med ; 59(6): 1143-1154, 2021 05 26.
Artículo en Inglés | MEDLINE | ID: mdl-33554557

RESUMEN

OBJECTIVES: Serological tests detect antibodies against Severe Acute Respiratory Syndrome Coronavirus 2 (SARS-CoV-2) in the ongoing coronavirus disease-19 (COVID-19) pandemic. Independent external clinical validation of performance characteristics is of paramount importance. METHODS: Four fully automated assays, Roche Elecsys Anti-SARS-CoV-2, Abbott SARS-CoV-2 IgG, Siemens SARS-CoV-2 total (COV2T) and SARS-CoV-2 IgG (COV2G) were evaluated using 350 pre-pandemic samples and 700 samples from 245 COVID-19 patients (158 hospitalized, 87 outpatients). RESULTS: All tests showed very high diagnostic specificity. Sensitivities in samples collected at least 14 days after disease onset were slightly lower than manufacturers' claims for Roche (93.0%), Abbott (90.8%), and Siemens COV2T (90.3%), and distinctly lower for Siemens COV2G (78.8%). Concordantly negative results were enriched for immunocompromised patients. ROC curve analyses suggest a lowering of the cut-off index for the Siemens COV2G assay. Finally, the combination of two anti-SARS-CoV-2 antibody assays is feasible when considering borderline reactive results. CONCLUSIONS: Thorough on-site evaluation of commercially available serologic tests for detection of antibodies against SARS-CoV-2 remains imperative for laboratories. The potentially impaired sensitivity of the Siemens COV2G necessitates a switch to the company's newly filed SARS-CoV-2 IgG assay for follow-up studies. A combination of tests could be considered in clinical practice.


Asunto(s)
Anticuerpos Antivirales/sangre , Prueba Serológica para COVID-19/métodos , COVID-19/diagnóstico , Inmunoglobulina G/sangre , Adulto , Anciano , Anciano de 80 o más Años , Anticuerpos Antivirales/inmunología , COVID-19/sangre , COVID-19/epidemiología , Femenino , Humanos , Inmunoglobulina G/inmunología , Masculino , Persona de Mediana Edad , Pandemias , Curva ROC , SARS-CoV-2/inmunología , Sensibilidad y Especificidad , Adulto Joven
9.
Clin Chem Lab Med ; 59(8): 1453-1462, 2021 07 27.
Artículo en Inglés | MEDLINE | ID: mdl-33837679

RESUMEN

OBJECTIVES: Severe acute respiratory syndrome coronavirus 2 (SARS-CoV-2) infections cause coronavirus disease 2019 (COVID-19) and induce a specific antibody response. Serological assays detecting IgG against the receptor binding domain (RBD) of the spike (S) protein are useful to monitor the immune response after infection or vaccination. The objective of our study was to evaluate the clinical performance of the Siemens SARS-CoV-2 IgG (sCOVG) assay. METHODS: Sensitivity and specificity of the Siemens sCOVG test were evaluated on 178 patients with SARS-CoV-2-infection and 160 pre-pandemic samples in comparison with its predecessor test COV2G. Furthermore, correlation with virus neutralization titers was investigated on 134 samples of convalescent COVID-19 patients. RESULTS: Specificity of the sCOVG test was 99.4% and sensitivity was 90.5% (COV2G assay 78.7%; p<0.0001). S1-RBD antibody levels showed a good correlation with virus neutralization titers (r=0.843; p<0.0001) and an overall qualitative agreement of 98.5%. Finally, median S1-RBD IgG levels increase with age and were significantly higher in hospitalized COVID-19 patients (median levels general ward: 25.7 U/mL; intensive care: 59.5 U/mL) than in outpatients (3.8 U/mL; p<0.0001). CONCLUSIONS: Performance characteristics of the sCOVG assay have been improved compared to the predecessor test COV2G. Quantitative SARS-CoV-2 S1-RBD IgG levels could be used as a surrogate for virus neutralization capacity. Further harmonization of antibody quantification might assist to monitor the humoral immune response after COVID-19 disease or vaccination.


Asunto(s)
Anticuerpos Neutralizantes/inmunología , Anticuerpos Antivirales/inmunología , COVID-19/diagnóstico , Inmunoglobulina G/inmunología , Pruebas de Neutralización , SARS-CoV-2/metabolismo , Glicoproteína de la Espiga del Coronavirus/inmunología , Adulto , Anciano , Anciano de 80 o más Años , Anticuerpos Neutralizantes/sangre , Anticuerpos Antivirales/sangre , COVID-19/patología , COVID-19/virología , Femenino , Humanos , Inmunoglobulina G/sangre , Masculino , Persona de Mediana Edad , Subunidades de Proteína/inmunología , Juego de Reactivos para Diagnóstico , SARS-CoV-2/aislamiento & purificación , Sensibilidad y Especificidad , Índice de Severidad de la Enfermedad , Adulto Joven
10.
Urol Int ; 105(7-8): 574-580, 2021.
Artículo en Inglés | MEDLINE | ID: mdl-33588413

RESUMEN

OBJECTIVE: The objective of this study was to predict computed tomography (CT)-controlled treatment success after minimally invasive percutaneous nephrolithotomy (Mini-PCNL). PATIENTS AND METHODS: We relied on retrospective single institutional data from 92 kidney stone patients treated with Mini-PCNL. Residual stones after treatment were evaluated by post-Mini-PCNL CT scans. Stone-free status was defined as clinically insignificant residual stones ≤3 mm after surgery. Multivariable logistic regression analyses predicted stone-free status after Mini-PCNL. RESULTS: Overall, 53 (57.6%) patients achieved stone-free status after Mini-PCNL treatment. In multivariable logistic regression analyses, stone localization was the strongest predictor for stone-free status after Mini-PCNL. Specifically, patients with exclusively pelvic stones were 7.1-fold more likely to achieve stone-free status than those patients with stones at multiple localizations (OR: 7.1; p = 0.005). Additionally, stone size represented a barrier for stone-free status (OR: 0.9; p = 0.03). CONCLUSIONS: Stone localization revealed the highest impact on treatment success after Mini-PCNL. Especially, those patients with exclusively pelvic stones were most likely to achieve stone-free status. Conversely, patients with multiple stone localizations were less likely to achieve stone-free status and need to be informed about higher risk of additional interventions after initial Mini-PCNL.


Asunto(s)
Cálculos Renales/diagnóstico por imagen , Cálculos Renales/cirugía , Nefrolitotomía Percutánea/métodos , Tomografía Computarizada por Rayos X , Femenino , Humanos , Masculino , Persona de Mediana Edad , Valor Predictivo de las Pruebas , Estudios Retrospectivos , Resultado del Tratamiento
11.
Klin Monbl Augenheilkd ; 238(8): 893-898, 2021 Aug.
Artículo en Inglés | MEDLINE | ID: mdl-33540463

RESUMEN

PURPOSE: To evaluate the effect of IPL (intense pulsed light) treatment in patients with meibomian gland dysfunction (MGD). METHODS: Clinical data of 25 patients with MGD who underwent IPL treatment at the department of ophthalmology of Ludwig-Maximilians-University between 2016 and 2018 were analyzed. Demographics, clinical history, examination findings (eyelid vascularization, meibomian gland findings, conjunctival redness, tear film break-up time [TFBUT], corneal staining (Oxford grading scale [OGS]), and subjective patients' findings (including ocular surface disease index [OSDI]) were collected from each visit (D1, D15, D45, D75). RESULTS: All included patients underwent three sessions of IPL treatment in both eyes (D1, D15, D45). There was a significant improvement after IPL treatment (D75) in TFBUT (p < 0.001), corneal staining (OGS) (p < 0.001), conjunctival redness (p < 0.001), lid margin edema (p < 0.001) and redness (p < 0.001), meibum quality (p < 0.001), lid margin telangiectasia (p = 0.005), meibomian gland obstruction (p = 0.001), and OSDI score (p = 0.004). Even after the first IPL session, significant improvements in TFBUT (p < 0.001), corneal staining (OGS p < 0.001), conjunctival redness (p < 0.022), lid margin edema (p < 0.001) and redness (p < 0.016), meibum quality (p = 0.014), and OSDI score (p < 0.013) were noted. There were no relevant negative side effects. Subgroup analysis for age, sex, duration or severity of disease, and associated diagnosis of rosacea showed no significant difference in effectiveness. CONCLUSION: IPL is an effective and safe treatment for patients with MGD, which can be used as a supportive therapeutic option.


Asunto(s)
Enfermedades de los Párpados , Disfunción de la Glándula de Meibomio , Oftalmología , Enfermedades de los Párpados/diagnóstico , Enfermedades de los Párpados/terapia , Humanos , Glándulas Tarsales , Lágrimas
12.
Klin Monbl Augenheilkd ; 238(11): 1213-1219, 2021 Nov.
Artículo en Inglés | MEDLINE | ID: mdl-34528231

RESUMEN

PURPOSE: To evaluate the reliability of spectral-domain optical coherence tomography (SD-OCT; RTVue XR; Optovue, Inc., Fremont, CA, USA) for thickness mapping of the entire cornea (CT), corneal epithelium (ET). and corneal stroma (ST) over a 9-mm zone in healthy eyes. We sought to develop reference values for different age groups and elucidate potential sex- and age-dependent characteristics of corneal sublayer pachymetry maps. METHODS: Three consecutive SD-OCT scans were obtained in 166 healthy right eyes (mean age = 50 ± 20 years). The thickness maps contain 25 sectors over a 9-mm diameter zone. To test measurement reliability, intraclass correlation coefficients (ICC), coefficients of variation (CoV), and within-subject standard deviations (WSSD) were calculated. RESULTS: CT, ET, and ST ICCs ranged from 0.961 to 0.998, 0.896 to 0.945, and 0.955 to 0.998, respectively. CoV values for CT, ET, and ST ranged between 0.3 and 1.5%, 1.6 and 4.2%, and 0.4 and 1.7%, respectively. WSSD ranged from 6 to 41, 4 to 8, and 7 to 46 µm, respectively. A negative correlation was found between age and ET (p < 0.05) but not between age and ST or CT. No gender-related differences in CT, ET, or ST were detected. CoV of CT, ET, and ST measurements showed a positive correlation with age in 28, 64, and 28% of the sectors, respectively. CONCLUSION: SD-OCT is a rapid and noninvasive technique that provides excellent reliability for corneal sublayer thickness measurements over a 9-mm zone. The reliability of the ET measurement seems to be negatively affected by age. Peripheral CT and global ET thin with age.


Asunto(s)
Epitelio Corneal , Tomografía de Coherencia Óptica , Adulto , Anciano , Córnea , Paquimetría Corneal , Epitelio Corneal/diagnóstico por imagen , Humanos , Persona de Mediana Edad , Reproducibilidad de los Resultados
13.
Klin Monbl Augenheilkd ; 238(8): 868-874, 2021 Aug.
Artículo en Inglés, Alemán | MEDLINE | ID: mdl-33853190

RESUMEN

BACKGROUND: Evaluation of the three currently most common techniques for intraocular lens (IOL) sclera fixation: (1) Prolene suture with Hoffman sclera pocket (2) four-point GoreTex suture technique (3) sutureless flanged intrascleral IOL fixation with double-needle ("Yamane") technique. MATERIAL AND METHODS: Retrospective, clinical case series (chart review) at the Department of Ophthalmology, Ludwig-Maximilians-University (LMU), Munich, Germany. Enrolled in the study were 51 patients with 55 eyes. Best-corrected visual acuity (BCVA); manifest refraction (OR); corneal tomography (central corneal thickness, CCT); biometry; central macular thickness (CMT) by optical coherence tomography (OCT); intraocular pressure (IOP); and IOL type and IOL power were recorded and compared prior to and 3 - 12 months post IOL sclera fixation surgery. Pre- and postsurgery difference analysis was performed by Wilcoxon rank sum testing (z). RESULTS: Intrascleral fixation by GoreTex suture was performed in 14 (25.5%) eyes, by Prolene suture in 19 (34.5%,) and by Yamane technique in 22 (40.0%) eyes. Within the 3 - 12 months follow-up post scleral fixation, a total of 2 (14.3%) eyes from the GoreTex, 3 (15.8%) from the Prolene and 1 (4.5%) eye from the Yamane group required refixation. Pre- and post-surgery analysis revealed a statistically significant difference in the total patient population BCVA (exact Wilcoxon test: z = - 3.202; p = 0.001; n = 55) and the Yamane subgroup (exact Wilcoxon test: z = - 2.068; p = 0.001; n = 22). The GoreTex (n = 14) and Prolene (n = 19) subgroups revealed no statistically significant differences versus preoperative baseline. Across groups, there was no statistically significant difference in IOP, CMT, and CCT. No retinal complications were observed, neither intraoperatively nor during follow-up. CONCLUSION: The volume of IOL revision surgery is increasing. Often, the only option left for visual rehabilitation is scleral IOL fixation. All three scleral fixation techniques studied demonstrated a good safety profile with no statistically significant impact on IOP, CMT, CCT, but with a notable revision rate. Visual rehabilitation to preoperative baseline levels (GoreTex [n = 14] and Prolene [n = 19]) and a statistically significant increase in visual acuity (total cohort [n = 55] and Yamane [n = 22]) seems possible. Unlike iris fixation, scleral fixation is surgically more complex and the surgeon must master a steeper learning curve.


Asunto(s)
Lentes Intraoculares , Esclerótica , Humanos , Implantación de Lentes Intraoculares , Estudios Retrospectivos , Esclerótica/diagnóstico por imagen , Esclerótica/cirugía , Agudeza Visual
14.
Klin Monbl Augenheilkd ; 238(11): 1220-1228, 2021 Nov.
Artículo en Inglés | MEDLINE | ID: mdl-34528232

RESUMEN

PURPOSE: To determine the effect of lockdown on medical care, with the example of ophthalmology. METHODS: Patients in a period during the first lockdown were compared to a non-lockdown period, with a total of 12 259 patients included in an observational study. Changes in different areas (elective, emergency, inpatients, surgeries) and eye care subspecialties were compared. Emergency patients were analyzed according to severity and urgency. Patients showing hints requiring treatment for urgent cardiovascular diseases were determined. Differences in patients who would have suffered severe vision loss without treatment were identified and the QALY (quality-adjusted life years) loss was determined accordingly. A model to prioritize patient visits after the end of lockdown or in future lockdown scenarios was developed. Data were collected at the University Eye Hospital LMU Munich and patient files were reviewed individually by ophthalmologists. RESULTS: The average patient number decreased by - 59.4% (p < 0.001), with a significant loss in all areas (elective, emergency, inpatients, surgeries; p < 0.001). There was a decline of - 39.6% for patients at high risk/high severity. Patients with indications of a risk factor of future stroke declined significantly (p = 0.003). QALY loss at the university eye hospital was 171, which was estimated to be 3160 - 24 143 for all of Germany. Working up high losses of outpatients during these 8 weeks of projected lockdown in Germany would take 7 - 23 weeks under normal circumstances, depending on ophthalmologist density. The prioritization model can reduce morbidity by up to 78%. CONCLUSION: There was marked loss of emergency cases and patients with chronic diseases. Making up for the losses in examinations and treatments will theoretically take weeks to months. To reduce the risk of morbidity, we recommend a prioritization model for rescheduling and future lockdown scenarios.


Asunto(s)
COVID-19 , Oftalmología , Control de Enfermedades Transmisibles , Humanos , Atención al Paciente , Estudios Retrospectivos , SARS-CoV-2
15.
BMC Ophthalmol ; 20(1): 77, 2020 Feb 27.
Artículo en Inglés | MEDLINE | ID: mdl-32103739

RESUMEN

BACKGROUND: Posterior capsule opacification (PCO) after cataract surgery is influenced by intraocular lens (IOL) design and material. The following is an ex vivo comparison of PCO between the Clareon vs. the AcrySof IOL in human capsular bags. METHODS: Twenty cadaver capsular bags from 10 human donors were used, with the novel hydrophobic IOL (Clareon, CNA0T0) being implanted in one eye and the other eye of the same donor receiving the AcrySof IOL (SN60WF) following phacoemulsification cataract surgery. Five capsular bags of 3 donors served as controls without IOL. Cellular growth of lens epithelial cells was photo-documented daily. The primary endpoint was the time until full coverage of the posterior capsule by cells. Furthermore, immunofluorescence staining of capsular bags for the fibrotic markers f-actin, fibronectin, alpha smooth muscle actin, and collagen type 1 were performed. RESULTS: The new Clareon IOL did not show any disadvantages in terms of days until full cell coverage of the posterior capsule in comparison to the AcrySof (p > 0.99). Both, the Clareon (p = 0.01, 14.8 days) and the AcrySof IOL (p = 0.005, 15.7 days) showed a slower PCO development in comparison to the control (8.6 days). The fibrotic markers f-actin, fibronectin, alpha smooth muscle actin, and collagen type 1 were equally distributed between the two IOLs and differed from the control. CONCLUSIONS: A comparable performance has been found in the ex vivo formation of PCO between the two IOLs. Long-term clinical studies are necessary to reach final conclusions.


Asunto(s)
Opacificación Capsular/diagnóstico , Implantación de Lentes Intraoculares , Lentes Intraoculares , Facoemulsificación , Cápsula Posterior del Cristalino/patología , Actinas/metabolismo , Anciano , Opacificación Capsular/metabolismo , Células Cultivadas , Colágeno Tipo I/metabolismo , Fibronectinas/metabolismo , Técnica del Anticuerpo Fluorescente Indirecta , Humanos , Persona de Mediana Edad , Cápsula Posterior del Cristalino/metabolismo , Diseño de Prótesis , Donantes de Tejidos , Agudeza Visual/fisiología
16.
Adv Exp Med Biol ; 1260: 123-139, 2020.
Artículo en Inglés | MEDLINE | ID: mdl-33211310

RESUMEN

Mixed, Augmented and Virtual reality technologies are burgeoning with new applications and use cases appearing rapidly. This chapter provides a brief overview of the fundamental display presentation methods; head-worn, hand-held and projector-based displays. We present a summary of visualisation methods that employ these technologies in the medical domain with a diverse range of examples presented including diagnostic and exploration, intervention and clinical, interaction and gestures, and education.


Asunto(s)
Realidad Aumentada , Educación Médica/métodos , Tecnología Educacional , Realidad Virtual
17.
Klin Monbl Augenheilkd ; 237(7): 907-919, 2020 Jul.
Artículo en Alemán | MEDLINE | ID: mdl-32303070

RESUMEN

This review article focusses on the management of enhancements after corneal refractive laser surgery. Fundamental issues regarding enhancement embrace identification of the underlying reason for postoperative ametropia, assurance of stability of refraction, type of primary refractive laser treatment and thorough evaluation of the given anatomical parameters of the cornea. With respect to specific inclusion and exclusion criteria, different surgical options for enhancement strategies are displayed with their particular advantages and disadvantages including preoperative planning of the according laser parameters and postoperative patient management.


Asunto(s)
Queratomileusis por Láser In Situ , Errores de Refracción , Procedimientos Quirúrgicos Refractivos , Córnea/cirugía , Topografía de la Córnea , Humanos , Periodo Posoperatorio , Refracción Ocular
18.
Klin Monbl Augenheilkd ; 237(12): e15-e34, 2020 Dec.
Artículo en Alemán | MEDLINE | ID: mdl-33207383

RESUMEN

Refractive lenticule extraction is a corneal surgical technique that uses a femtosecond laser exclusively to create an intrastromal refractive lenticule for the correction of myopia and myopic astigmatism. In small incision lenticule extraction (SMILE) the generated refractive lenticule is subsequently extracted through a small incision. The reported efficacy, predictability and safety of the flap-less SMILE procedure is similar to those of femtosecond laser in situ keratomileusis (LASIK). Advantages of SMILE over LASIK include less iatrogenic dry eye, fewer induced higher-order aberrations, and potentially less biomechanical weakening of the cornea. However, there is a steeper surgeon learning curve for SMILE as the procedure is technically more challenging than LASIK. Furthermore, the current SMILE laser platform cannot use cyclotorsion control or eye-tracking technology and retreatment options are more complex compared to LASIK. This review looks at patient selection, surgical method, possible complications, retreatment options, and postoperative outcome of the SMILE technique.


Asunto(s)
Astigmatismo , Queratomileusis por Láser In Situ , Miopía , Astigmatismo/cirugía , Córnea , Sustancia Propia , Humanos , Láseres de Excímeros , Miopía/cirugía , Agudeza Visual
19.
Klin Monbl Augenheilkd ; 237(5): 675-680, 2020 May.
Artículo en Inglés, Alemán | MEDLINE | ID: mdl-32375197

RESUMEN

PURPOSE: To perform a systematic analysis of articles on the ophthalmological implications of the global COVID-19 pandemic. METHODS: PubMed.gov was searched for relevant articles using the keywords "COVID-19", "coronavirus", and "SARS-CoV-2" in conjunction with "ophthalmology" and "eye". Moreover, official recommendations of ophthalmological societies were systematically reviewed, with a focus on the American Academy of Ophthalmology (AAO) and the Royal College of Ophthalmologists (RCOphth). RESULTS: As of April 16, 2020, in total, 21 peer-reviewed articles on the ophthalmological aspects of COVID-19 were identified. Of these, 12 (57.1%) were from Asia, 6 (28.6%) from the United States of America, and 3 (14.3%) from Europe. There were 5 (23.8%) original studies, 10 (47.6%) letters, 3 (14.2%) case reports, and 3 (14.2%) reviews. These articles could be classified into the topics "Modes and prevention of (ocular) transmission", "Ophthalmological manifestations of COVID-19", "Clinical guidance concerning ophthalmological practice during the COVID-19 pandemic", and "Practical recommendations for clinical infrastructure". Practical recommendations could be extracted from official statements of the AAO and the RCOphth. CONCLUSION: Within a short period, a growing body of articles has started to elucidate the ophthalmological implications of COVID-19. As the eye can represent a route of infection (actively via tears and passively via the nasoacrimal duct), ophthalmological care has to undergo substantial modifications during this pandemic. In the eye, COVID-19 can manifest as keratoconjunctivitis.


Asunto(s)
Infecciones por Coronavirus , Queratoconjuntivitis , Conducto Nasolagrimal/virología , Oftalmología , Pandemias , Neumonía Viral , Coronavirus Relacionado al Síndrome Respiratorio Agudo Severo , Lágrimas/virología , Betacoronavirus/patogenicidad , COVID-19 , Infecciones por Coronavirus/complicaciones , Infecciones por Coronavirus/transmisión , Humanos , Queratoconjuntivitis/virología , Neumonía Viral/complicaciones , Neumonía Viral/transmisión , SARS-CoV-2
20.
Lasers Med Sci ; 34(6): 1229-1234, 2019 Aug.
Artículo en Inglés | MEDLINE | ID: mdl-30661184

RESUMEN

To evaluate the required cumulative dissipated energy (CDE) to fragment the crystalline lens in femtosecond laser-assisted cataract surgery (FLACS) in relation to lens density and lens thickness. Consecutive eyes that underwent FLACS between September 2014 and March 2017 by a single surgeon using in all cases the same femtosecond laser and phacoemulsification platform were included in our retrospective study. Prior to surgery, corrected distance visual acuity (CDVA), optical biometry corneal, and crystalline lens tomographies were performed to assess anterior chamber depth (ACD), axial length (AL), and crystalline lens parameters (i.e., lens density, thickness, and nucleus staging (NS)). After surgery, CDE was calculated and analyzed in relation to lens density (LD) and lens thickness (LT). Zero ultrasound expenditure cases were recorded and their occurrence analyzed. The chart review identified 236 eyes of 200 patients, 98 males and 102 females aged 65± 15 years which were included in the study. Mean LD was 11.26 ± 2.05 pixel intensity units (range 7.30-18.80), and the mean LT was 3417 ± 405.17 µm (range 2545-4701). LD and LT correlated moderately (r = 0.50, p < 0.001) and weakly (r = 0.23, p < 0.001), with post-laser CDE. Higher LD and LT were also associated with lower rates of zero phaco (eyes in which no phacoemulsification energy was necessary). Furthermore, NS (r = 0.528, p < 0.001) and CDVA (r = - 0.3524, p < 0.001) also correlated with CDE. Higher LD, LT, NS values, and low CDVA are associated with higher ultrasound expenditure (CDE-cumulative dissipated energy) and with lower rates of zero ultrasound expenditure during FLACS.


Asunto(s)
Extracción de Catarata , Terapia por Láser , Cristalino/cirugía , Adulto , Anciano , Anciano de 80 o más Años , Femenino , Humanos , Masculino , Persona de Mediana Edad , Facoemulsificación , Cuidados Preoperatorios , Estudios Prospectivos , Análisis de Regresión , Estudios Retrospectivos , Agudeza Visual
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA