Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 8 de 8
Filtrar
1.
Magn Reson Med ; 91(6): 2559-2567, 2024 Jun.
Artículo en Inglés | MEDLINE | ID: mdl-38205934

RESUMEN

PURPOSE: To investigate the safety and value of hyperpolarized (HP) MRI of [1-13C]pyruvate in healthy volunteers using deuterium oxide (D2O) as a solvent. METHODS: Healthy volunteers (n = 5), were injected with HP [1-13C]pyruvate dissolved in D2O and imaged with a metabolite-specific 3D dual-echo dynamic EPI sequence at 3T at one site (Site 1). Volunteers were monitored following the procedure to assess safety. Image characteristics, including SNR, were compared to data acquired in a separate cohort using water as a solvent (n = 5) at another site (Site 2). The apparent spin-lattice relaxation time (T1) of [1-13C]pyruvate was determined both in vitro and in vivo from a mono-exponential fit to the image intensity at each time point of our dynamic data. RESULTS: All volunteers completed the study safely and reported no adverse effects. The use of D2O increased the T1 of [1-13C]pyruvate from 66.5 ± 1.6 s to 92.1 ± 5.1 s in vitro, which resulted in an increase in signal by a factor of 1.46 ± 0.03 at the time of injection (90 s after dissolution). The use of D2O also increased the apparent relaxation time of [1-13C]pyruvate by a factor of 1.4 ± 0.2 in vivo. After adjusting for inter-site SNR differences, the use of D2O was shown to increase image SNR by a factor of 2.6 ± 0.2 in humans. CONCLUSIONS: HP [1-13C]pyruvate in D2O is safe for human imaging and provides an increase in T1 and SNR that may improve image quality.


Asunto(s)
Imagen por Resonancia Magnética , Ácido Pirúvico , Humanos , Estudios de Factibilidad , Imagen por Resonancia Magnética/métodos , Encéfalo/diagnóstico por imagen , Isótopos de Carbono , Solventes
2.
Eur Radiol ; 34(8): 5120-5130, 2024 Aug.
Artículo en Inglés | MEDLINE | ID: mdl-38206405

RESUMEN

OBJECTIVES: To assess radiologists' current use of, and opinions on, structured reporting (SR) in oncologic imaging, and to provide recommendations for a structured report template. MATERIALS AND METHODS: An online survey with 28 questions was sent to European Society of Oncologic Imaging (ESOI) members. The questionnaire had four main parts: (1) participant information, e.g., country, workplace, experience, and current SR use; (2) SR design, e.g., numbers of sections and fields, and template use; (3) clinical impact of SR, e.g., on report quality and length, workload, and communication with clinicians; and (4) preferences for an oncology-focused structured CT report. Data analysis comprised descriptive statistics, chi-square tests, and Spearman correlation coefficients. RESULTS: A total of 200 radiologists from 51 countries completed the survey: 57.0% currently utilized SR (57%), with a lower proportion within than outside of Europe (51.0 vs. 72.7%; p = 0.006). Among SR users, the majority observed markedly increased report quality (62.3%) and easier comparison to previous exams (53.5%), a slightly lower error rate (50.9%), and fewer calls/emails by clinicians (78.9%) due to SR. The perceived impact of SR on communication with clinicians (i.e., frequency of calls/emails) differed with radiologists' experience (p < 0.001), and experience also showed low but significant correlations with communication with clinicians (r = - 0.27, p = 0.003), report quality (r = 0.19, p = 0.043), and error rate (r = - 0.22, p = 0.016). Template use also affected the perceived impact of SR on report quality (p = 0.036). CONCLUSION: Radiologists regard SR in oncologic imaging favorably, with perceived positive effects on report quality, error rate, comparison of serial exams, and communication with clinicians. CLINICAL RELEVANCE STATEMENT: Radiologists believe that structured reporting in oncologic imaging improves report quality, decreases the error rate, and enables better communication with clinicians. Implementation of structured reporting in Europe is currently below the international level and needs society endorsement. KEY POINTS: • The majority of oncologic imaging specialists (57% overall; 51% in Europe) use structured reporting in clinical practice. • The vast majority of oncologic imaging specialists use templates (92.1%), which are typically cancer-specific (76.2%). • Structured reporting is perceived to markedly improve report quality, communication with clinicians, and comparison to prior scans.


Asunto(s)
Actitud del Personal de Salud , Neoplasias , Radiólogos , Sociedades Médicas , Humanos , Europa (Continente) , Encuestas y Cuestionarios , Neoplasias/diagnóstico por imagen , Radiólogos/estadística & datos numéricos , Sistemas de Información Radiológica/estadística & datos numéricos
4.
Eur J Radiol ; 179: 111665, 2024 Aug 05.
Artículo en Inglés | MEDLINE | ID: mdl-39128251

RESUMEN

AIM: To investigate the associations between the hour of the day and Prostate Imaging-Reporting and Data System (PI-RADS) scores assigned by radiologists in prostate MRI reports. MATERIALS AND METHODS: Retrospective single-center collection of prostate MRI reports over an 8-year period. Mean PI-RADS scores assigned between 0800 and 1800 h were examined with a regression model. RESULTS: A total of 35'004 prostate MRI interpretations by 26 radiologists were included. A significant association between the hour of day and mean PI-RADS score was identified (ß2 = 0.005, p < 0.001), with malignant scores more frequently assigned later in the day. CONCLUSION: These findings suggest chronobiological factors may contribute to variability in radiological assessments. Though the magnitude of the effect is small, this may potentially add variability and impact diagnostic accuracy.

5.
Invest Radiol ; 2024 Jun 14.
Artículo en Inglés | MEDLINE | ID: mdl-38896439

RESUMEN

OBJECTIVES: The aim of this study was to determine whether MRI radiomic features of key cerebral structures differ between women and men, and whether detection of such differences depends on the image resolution. MATERIALS AND METHODS: Ultrahigh resolution (UHR) 3D MP2RAGE (magnetization-prepared 2 rapid acquisition gradient echo) T1-weighted MR images (voxel size, 0.7 × 0.7 × 0.7 mm3) of the brain of 30 subjects (18 women and 12 men; mean age, 39.0 ± 14.8 years) without abnormal findings on MRI were retrospectively included. MRI was performed on a whole-body 7 T MR system. A convolutional neural network was used to segment the following structures: frontal cortex, frontal white matter, thalamus, putamen, globus pallidus, caudate nucleus, and corpus callosum. Eighty-seven radiomic features were extracted respectively: gray-level histogram (n = 18), co-occurrence matrix (n = 24), run-length matrix (n = 16), size-zone matrix (n = 16), and dependence matrix (n = 13). Feature extraction was performed at UHR and, additionally, also after resampling to 1.4 × 1.4 × 1.4 mm3 voxel size (standard clinical resolution). Principal components (PCs) of radiomic features were calculated, and independent samples t tests with Cohen d as effect size measure were used to assess differences in PCs between women and men for the different cerebral structures. RESULTS: At UHR, at least a single PC differed significantly between women and men in 6/7 cerebral structures: frontal cortex (d = -0.79, P = 0.042 and d = -1.01, P = 0.010), frontal white matter (d = -0.81, P = 0.039), thalamus (d = 1.43, P < 0.001), globus pallidus (d = 0.92, P = 0.020), caudate nucleus (d = -0.83, P = 0.039), and corpus callosum (d = -0.97, P = 0.039). At standard clinical resolution, only a single PC extracted from the corpus callosum differed between sexes (d = 1.05, P = 0.009). CONCLUSIONS: Nonnegligible differences in radiomic features of several key structures of the brain exist between women and men, and need to be accounted for. Very high spatial resolution may be required to uncover and further investigate the sexual dimorphism of brain structures on MRI.

6.
Endocr Relat Cancer ; 31(3)2024 Mar 01.
Artículo en Inglés | MEDLINE | ID: mdl-38214923

RESUMEN

The chemotherapy regimen capecitabine/temozolomide (CAPTEM) is routinely used in neuroendocrine tumors (NET), with antitumor activity particularly demonstrated in pancreatic or high-grade neuroendocrine neoplasms (NEN). However, different dosing regimens are used, and the optimal schedule remains to be defined. This single-center retrospective analysis assessed the efficacy and safety of CAPTEM in patients with NEN using a schedule starting both compounds simultaneously (temozolomide on days 1-5 and capecitabine on days 1-14 of a 28-day cycle) rather than sequentially. The primary parameters of interest were response rates, progression-free survival (PFS), and toxicities following this treatment regimen, hereinafter referred to as TEMCAP. The study population comprised 40 patients, half of whom (n = 20) had pancreatic NEN, and 9 patients (22.5%) had pulmonary or thymic NETs. The most common histology was NET G3 (n = 15, 37.5%), and 8 patients (20.0%) had a neuroendocrine carcinoma (NEC). Most patients (77.5%) had at least one prior systemic therapy, and 16 patients (40.0%) prior chemotherapy. The median number of TEMCAP cycles was 6 (range 1-16). Median PFS for the highly heterogeneous population was 13.3 months, while the median overall survival was 31.9 months. In total, 14/36 patients (38.9%) exhibited a partial response, and the disease control rate was 75.0%. The safety profile of TEMCAP (at a below-target mean temozolomide dose of 118.85 mg/m2) in our cohort was remarkably good with no toxicities of grade 3 or 4. Taken together, the results of this analysis further support the use of temozolomide/capecitabine in NEN and prompt further assessment of our modified TEMCAP schedule.


Asunto(s)
Tumores Neuroendocrinos , Neoplasias Pancreáticas , Humanos , Temozolomida/uso terapéutico , Capecitabina/uso terapéutico , Capecitabina/efectos adversos , Estudios Retrospectivos , Protocolos de Quimioterapia Combinada Antineoplásica/uso terapéutico , Tumores Neuroendocrinos/patología , Neoplasias Pancreáticas/patología , Resultado del Tratamiento
7.
Lancet Digit Health ; 6(2): e114-e125, 2024 Feb.
Artículo en Inglés | MEDLINE | ID: mdl-38135556

RESUMEN

BACKGROUND: The rising global cancer burden has led to an increasing demand for imaging tests such as [18F]fluorodeoxyglucose ([18F]FDG)-PET-CT. To aid imaging specialists in dealing with high scan volumes, we aimed to train a deep learning artificial intelligence algorithm to classify [18F]FDG-PET-CT scans of patients with lymphoma with or without hypermetabolic tumour sites. METHODS: In this retrospective analysis we collected 16 583 [18F]FDG-PET-CTs of 5072 patients with lymphoma who had undergone PET-CT before or after treatment at the Memorial Sloa Kettering Cancer Center, New York, NY, USA. Using maximum intensity projection (MIP), three dimensional (3D) PET, and 3D CT data, our ResNet34-based deep learning model (Lymphoma Artificial Reader System [LARS]) for [18F]FDG-PET-CT binary classification (Deauville 1-3 vs 4-5), was trained on 80% of the dataset, and tested on 20% of this dataset. For external testing, 1000 [18F]FDG-PET-CTs were obtained from a second centre (Medical University of Vienna, Vienna, Austria). Seven model variants were evaluated, including MIP-based LARS-avg (optimised for accuracy) and LARS-max (optimised for sensitivity), and 3D PET-CT-based LARS-ptct. Following expert curation, areas under the curve (AUCs), accuracies, sensitivities, and specificities were calculated. FINDINGS: In the internal test cohort (3325 PET-CTs, 1012 patients), LARS-avg achieved an AUC of 0·949 (95% CI 0·942-0·956), accuracy of 0·890 (0·879-0·901), sensitivity of 0·868 (0·851-0·885), and specificity of 0·913 (0·899-0·925); LARS-max achieved an AUC of 0·949 (0·942-0·956), accuracy of 0·868 (0·858-0·879), sensitivity of 0·909 (0·896-0·924), and specificity of 0·826 (0·808-0·843); and LARS-ptct achieved an AUC of 0·939 (0·930-0·948), accuracy of 0·875 (0·864-0·887), sensitivity of 0·836 (0·817-0·855), and specificity of 0·915 (0·901-0·927). In the external test cohort (1000 PET-CTs, 503 patients), LARS-avg achieved an AUC of 0·953 (0·938-0·966), accuracy of 0·907 (0·888-0·925), sensitivity of 0·874 (0·843-0·904), and specificity of 0·949 (0·921-0·960); LARS-max achieved an AUC of 0·952 (0·937-0·965), accuracy of 0·898 (0·878-0·916), sensitivity of 0·899 (0·871-0·926), and specificity of 0·897 (0·871-0·922); and LARS-ptct achieved an AUC of 0·932 (0·915-0·948), accuracy of 0·870 (0·850-0·891), sensitivity of 0·827 (0·793-0·863), and specificity of 0·913 (0·889-0·937). INTERPRETATION: Deep learning accurately distinguishes between [18F]FDG-PET-CT scans of lymphoma patients with and without hypermetabolic tumour sites. Deep learning might therefore be potentially useful to rule out the presence of metabolically active disease in such patients, or serve as a second reader or decision support tool. FUNDING: National Institutes of Health-National Cancer Institute Cancer Center Support Grant.


Asunto(s)
Aprendizaje Profundo , Linfoma , Estados Unidos , Humanos , Tomografía Computarizada por Tomografía de Emisión de Positrones/métodos , Fluorodesoxiglucosa F18 , Estudios Retrospectivos , Inteligencia Artificial , Radiofármacos , Linfoma/diagnóstico por imagen
8.
J Hematol Oncol ; 17(1): 21, 2024 Apr 23.
Artículo en Inglés | MEDLINE | ID: mdl-38649972

RESUMEN

Relapse and toxicity limit the effectiveness of chimeric antigen receptor T-cell (CAR-T) therapy for large B-cell lymphoma (LBCL), yet biomarkers that predict outcomes and toxicity are lacking. We examined radiomic features extracted from pre-CAR-T 18F-fluorodeoxyglucose positron emission tomography/computed tomography ([18F]FDG PET/CT) scans (n = 341) of 180 patients (121 male; median age, 66 years). Three conventional (maximum standardized uptake value [SUVmax], metabolic tumor volume [MTV], total lesion glycolysis [TLG]) and 116 novel radiomic features were assessed, along with inflammatory markers, toxicities, and outcomes. At both pre-apheresis and pre-infusion time points, conventional PET features of disease correlated with elevated inflammatory markers. At pre-infusion, MTV was associated with grade ≥ 2 cytokine release syndrome (odds ratio [OR] for 100 mL increase: 1.08 [95% confidence interval (CI), 1.01-1.20], P = 0.031), and SUVmax was associated with failure to achieve complete response (CR) (OR 1.72 [95% CI, 1.24-2.43], P < 0.001). Higher pre-apheresis and pre-infusion MTV values were associated with shorter progression-free survival (PFS) (HR for 10-unit increase: 1.11 [95% CI, 1.05-1.17], P < 0.001; 1.04 [95% CI, 1.02-1.07], P < 0.001) and shorter overall survival (HR for 100-unit increase: 1.14 [95% CI, 1.07-1.21], P < 0.001; 1.04 [95% CI, 1.02-1.06], P < 0.001). A combined MTV and LDH measure stratified patients into high and low PFS risk groups. Multiple pre-infusion novel radiomic features were associated with CR. These quantitative conventional [18F]FDG PET/CT features obtained before CAR-T cell infusion, which were correlated with inflammation markers, may provide prognostic biomarkers for CAR-T therapy efficacy and toxicity. The use of conventional and novel radiomic features may thus help identify high-risk patients for earlier interventions.


Asunto(s)
Fluorodesoxiglucosa F18 , Inmunoterapia Adoptiva , Linfoma de Células B Grandes Difuso , Tomografía Computarizada por Tomografía de Emisión de Positrones , Humanos , Masculino , Femenino , Tomografía Computarizada por Tomografía de Emisión de Positrones/métodos , Anciano , Inmunoterapia Adoptiva/métodos , Persona de Mediana Edad , Linfoma de Células B Grandes Difuso/terapia , Linfoma de Células B Grandes Difuso/diagnóstico por imagen , Adulto , Resultado del Tratamiento , Anciano de 80 o más Años , Radiofármacos , Pronóstico , Estudios Retrospectivos
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA