Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 77
Filtrar
Más filtros

Bases de datos
País/Región como asunto
Tipo del documento
Intervalo de año de publicación
1.
Sensors (Basel) ; 23(8)2023 Apr 08.
Artículo en Inglés | MEDLINE | ID: mdl-37112164

RESUMEN

Hydrogen is an efficient source of clean and environmentally friendly energy. However, because it is explosive at concentrations higher than 4%, safety issues are a great concern. As its applications are extended, the need for the production of reliable monitoring systems is urgent. In this work, mixed copper-titanium oxide ((CuTi)Ox) thin films with various copper concentrations (0-100 at.%), deposited by magnetron sputtering and annealed at 473 K, were investigated as a prospective hydrogen gas sensing material. Scanning electron microscopy was applied to determine the morphology of the thin films. Their structure and chemical composition were investigated by X-ray diffraction and X-ray photoelectron spectroscopy, respectively. The prepared films were nanocrystalline mixtures of metallic copper, cuprous oxide, and titanium anatase in the bulk, whereas at the surface only cupric oxide was found. In comparison to the literature, the (CuTi)Ox thin films already showed a sensor response to hydrogen at a relatively low operating temperature of 473 K without using any extra catalyst. The best sensor response and sensitivity to hydrogen gas were found in the mixed copper-titanium oxides containing similar atomic concentrations of both metals, i.e., 41/59 and 56/44 of Cu/Ti. Most probably, this effect is related to their similar morphology and to the simultaneous presence of Cu and Cu2O crystals in these mixed oxide films. In particular, the studies of surface oxidation state revealed that it was the same for all annealed films and consisted only of CuO. However, in view of their crystalline structure, they consisted of Cu and Cu2O nanocrystals in the thin film volume.

2.
J Card Surg ; 37(10): 3267-3275, 2022 Oct.
Artículo en Inglés | MEDLINE | ID: mdl-35989503

RESUMEN

BACKGROUND: Minimally invasive mitral valve repair (MVr) is commonly performed. Data on the outcomes of robotic MVr versus nonrobotic minimally invasive MVr are lacking. We sought to compare the short-term and mid-term outcomes of robotic and nonrobotic MVr. METHODS: We reviewed all patients who underwent robotic MVr (n = 424) or nonrobotic MVr via right mini-thoracotomy (n = 86) at Mayo Clinic, Rochester, MN, from January 2015 to February 2020. Data on baseline and operative characteristics, operative and long-term outcomes were analyzed. Patients were matched 1:1 using propensity scores. RESULTS: Sixty-nine matched pairs were included in the study. The median age was 59 years (interquartile range [IQR]: 54-69) and 75% (n = 103) were male. Baseline characteristics were similar after matching. Robotic and nonrobotic MVr had similar operative characteristics, except that robotic had longer cross-clamp times (57 [48-67] vs. 47 [37-58] min, p < .001) and more P2 resections (83% vs. 68%, p = .05) compared to nonrobotic MVr. There was no difference in operative outcomes between groups. Hospital stay was shorter after robotic MVr (4 [3-4] vs. 4 [4-6] days, p = .003). After a median follow-up of 3.3 years (IQR, 2.1-4.5), there was no mortality in either group, and there was no difference in freedom from mitral valve reoperations between robotic and nonrobotic MVr (5 years: 97.1% vs. 95.7%, p = .63). Follow-up echocardiogram analysis predicted excellent freedom from recurrent moderate-or-severe mitral regurgitation at 3 years after robotic and nonrobotic MVr (90% vs. 92%, p = .18, respectively). CONCLUSIONS: Both short-term and mid-term outcomes of robotic and nonrobotic minimally invasive mitral repair surgery are comparable.


Asunto(s)
Procedimientos Quirúrgicos Cardíacos , Procedimientos Quirúrgicos Mínimamente Invasivos , Insuficiencia de la Válvula Mitral , Procedimientos Quirúrgicos Robotizados , Anciano , Procedimientos Quirúrgicos Cardíacos/efectos adversos , Procedimientos Quirúrgicos Cardíacos/métodos , Femenino , Humanos , Masculino , Persona de Mediana Edad , Procedimientos Quirúrgicos Mínimamente Invasivos/efectos adversos , Insuficiencia de la Válvula Mitral/cirugía , Procedimientos Quirúrgicos Robotizados/efectos adversos , Resultado del Tratamiento
3.
Diabetologia ; 64(11): 2562-2574, 2021 11.
Artículo en Inglés | MEDLINE | ID: mdl-34494136

RESUMEN

AIMS/HYPOTHESIS: Type 2 diabetes has been demonstrated to predispose to aortic valve calcification. We investigated whether type 2 diabetes concomitant to aortic stenosis (AS) enhances valvular inflammation and coagulation activation via upregulated expression of NF-κB, with subsequent increased expression of bone morphogenetic protein 2 (BMP-2). METHODS: In this case-control study, 50 individuals with severe isolated AS and concomitant type 2 diabetes were compared with a control group of 100 individuals without diabetes. The median (IQR) duration of diabetes since diagnosis was 11 (7-18) years, and 36 (72%) individuals had HbA1c ≥48 mmol/mol (≥6.5%). Stenotic aortic valves obtained during valve replacement surgery served for in loco NF-κB, BMP-2, prothrombin (FII) and active factor X (FXa) immunostaining. In vitro cultures of valve interstitial cells (VICs), isolated from obtained valves were used for mechanistic experiments and PCR investigations. RESULTS: Diabetic compared with non-diabetic individuals displayed enhanced valvular expression of NF-κB, BMP-2, FII and FXa (all p ≤ 0.001). Moreover, the expression of NF-κB and BMP-2 positively correlated with amounts of valvular FII and FXa. Only in diabetic participants, valvular NF-κB expression was strongly associated with serum levels of HbA1c, and moderately with fructosamine. Of importance, in diabetic participants, valvular expression of NF-κB correlated with aortic valve area (AVA) and maximal transvalvular pressure gradient. In vitro experiments conducted using VIC cultures revealed that glucose (11 mmol/l) upregulated expression of both NF-κB and BMP-2 (p < 0.001). In VIC cultures treated with glucose in combination with reactive oxygen species (ROS) inhibitor (N-acetyl-L-cysteine), the expression of NF-κB and BMP-2 was significantly suppressed. A comparable effect was observed for VICs cultured with glucose in combination with NF-κB inhibitor (BAY 11-7082), suggesting that high doses of glucose activate oxidative stress leading to proinflammatory actions in VICs. Analysis of mRNA expression in VICs confirmed these findings; glucose caused a 6.9-fold increase in expression of RELA (NF-κB p65 subunit), with the ROS and NF-κB inhibitor reducing the raised expression of RELA by 1.8- and 3.2-fold, respectively. CONCLUSIONS/INTERPRETATION: Type 2 diabetes enhances in loco inflammation and coagulation activation within stenotic valve leaflets. Increased valvular expression of NF-κB in diabetic individuals is associated not only with serum HbA1c and fructosamine levels but also with AVA and transvalvular gradient, indicating that strict long-term glycaemic control is needed in AS patients with concomitant type 2 diabetes. This study suggests that maintaining these variables within the normal range may slow the rate of AS progression.


Asunto(s)
Estenosis de la Válvula Aórtica/complicaciones , Válvula Aórtica/patología , Calcinosis/etiología , Diabetes Mellitus Tipo 2/complicaciones , FN-kappa B/metabolismo , Anciano , Válvula Aórtica/metabolismo , Estenosis de la Válvula Aórtica/etiología , Estenosis de la Válvula Aórtica/metabolismo , Proteína Morfogenética Ósea 2/metabolismo , Calcinosis/metabolismo , Estudios de Casos y Controles , Células Cultivadas , Ensayo de Inmunoadsorción Enzimática , Femenino , Técnica del Anticuerpo Fluorescente Indirecta , Humanos , Masculino , Persona de Mediana Edad , Reacción en Cadena en Tiempo Real de la Polimerasa
5.
J Cardiovasc Electrophysiol ; 32(1): 93-101, 2021 01.
Artículo en Inglés | MEDLINE | ID: mdl-33146462

RESUMEN

BACKGROUND: Left atrial appendage closure (LAAC) became an alternative method for stroke prevention in patients with non-valvular atrial fibrillation (AF) intolerant to long term oral anticoagulation therapy. This study aimed to compare endocardial (Amulet and LAmbere occluders) and epicardial (Lariat) LAAC techniques. METHODS: A retrospective, observational case-control study included 223 consecutive CHA2 DS2 -VAS score-matched patients with AF who underwent LAAC in two centers. RESULTS: There were 55 matched cases with the mean CHA2DS2-VASs score 4.4 ± 1.22 (p = 1). Overall follow-up was 308.2 patient-years. The Endocardial group patients were older and more often females with congestive heart failure and peripheral vascular disease. The epicardial group more frequently had a stroke/transient ischemic attack history. There were no differences in hypertension, diabetes mellitus, and indications for procedure between both groups. The mean HAS-BLED score was significantly higher in the endocardial group than in the epicardial group (4.3 ± 0.9 vs. 3.7 ± 1.3, p = .011). There were no differences in annual rates of thromboembolic events (2.6% vs 0.5%) and annual stroke (0.87% vs. 0%) between the endocardial and epicardial groups. CONCLUSION: Endocardial and Epicardial LAAC techniques show comparable implantation outcomes and safety profile and stroke prevention in patients with AF. Future randomized studies are needed to corroborate these initial results and assess long term mortality.


Asunto(s)
Apéndice Atrial , Fibrilación Atrial , Accidente Cerebrovascular , Apéndice Atrial/cirugía , Fibrilación Atrial/complicaciones , Fibrilación Atrial/diagnóstico , Fibrilación Atrial/cirugía , Estudios de Casos y Controles , Femenino , Estudios de Seguimiento , Humanos , Estudios Retrospectivos , Accidente Cerebrovascular/diagnóstico , Accidente Cerebrovascular/etiología , Accidente Cerebrovascular/prevención & control , Resultado del Tratamiento
6.
Artif Organs ; 45(11): 1360-1367, 2021 Nov.
Artículo en Inglés | MEDLINE | ID: mdl-34219241

RESUMEN

Severe accidental hypothermia carries high mortality and morbidity and is often treated with invasive extracorporeal methods. Continuous veno-venous hemodiafiltration (CVVHDF) is widely available in intensive care units. We sought to provide theoretical basis for CVVHDF use in rewarming of hypothermic patients. CVVHDF system was used in the laboratory setting. Heat balance and transferred heat units were evaluated for the system without using blood. We used 5L of crystalloid solution at the temperature of approximately 25°C, placed in a thermally insulated tank (representing the "central compartment" of a hypothermic patient). Time of warming the central compartment from 24.9 to 30.0°C was assessed with different flow combinations: "blood" (central compartment fluid) 50 or 100 or 150 mL/min, dialysate solution 100 or 1500 mL/h, and substitution fluid 0 or 500 mL/h. The total circulation time was 1535 minutes. There were no differences between heat gain values on the filter depending on blood flow (P = .53) or dialysate flow (P = .2). The mean heating time for "blood" flow rates 50, 100, and 150 mL/min was 113.7 minutes (95% CI, 104.9-122.6 minutes), 83.3 minutes (95% CI, 76.2-90.3 minutes), and 74.7 minutes (95% CI, 62.6-86.9 minutes), respectively (P < .01). The respective median rewarming rate for different "blood" flows was 3.6°C/h (IQR, 3.0-4.2°C/h), 4.8 (IQR, 4.2-5.4°C/h), and 5.4 (IQR, 4.8-6.0°C/h), respectively (P < .01). The dialysate flow did not affect the warming rate. Based on our experimental model, CVVHDF may be used for extracorporeal rewarming, with the rewarming rates increasing achieved with higher blood flow rates.


Asunto(s)
Terapia de Reemplazo Renal Continuo/métodos , Hipotermia/terapia , Recalentamiento/métodos , Hemodinámica , Humanos
7.
Cardiovasc Diabetol ; 19(1): 92, 2020 06 17.
Artículo en Inglés | MEDLINE | ID: mdl-32552684

RESUMEN

BACKGROUND: Accumulation of advanced glycation end products (AGEs) leads to chronic glycation of proteins and tissue damage, particularly in patients with diabetes mellitus (DM). We aimed to evaluate whether increased accumulation of AGEs in patients with aortic stenosis (AS) and concomitant type 2 diabetes (DM) is associated with AS severity. METHODS: We prospectively enrolled 76 patients with severe AS (47.1% males; nonDM), aged 68 [66-72] years, and 50 age-matched DM patients with a median blood glucose level of 7.5 [5.9-9.1] mM and glycated hemoglobin (HbA1c) of 6.8 [6.3-7.8]%, scheduled for aortic valve replacement. Valvular expression of AGEs, AGEs receptor (RAGE), interleukin-6 (IL-6), and reactive oxygen species (ROS) induction were evaluated ex vivo by immunostaining and calculated as the extent of positive immunoreactive areas/total sample area. Plasma levels of AGEs and soluble RAGE (sRAGE) were assessed by ELISAs. RESULTS: Subjects with DM had increased valvular expression of both AGEs (6.6-fold higher, 15.53 [9.96-23.28]%) and RAGE (1.8-fold higher, 6.8 [4.9-8.45]%) compared to nonDM patients (2.05 [1.21-2.58]% and 2.4 [1.56-3.02]%, respectively; both p < 0.001). Plasma levels of AGEs (12-fold higher) and sRAGE (1.3-fold higher) were elevated in DM patients, compared to nonDM (both p < 0.0001). The percentage of valvular ROS-positive (2.28 [1.6-3.09] vs. 1.15 [0.94-1.4]%, p < 0.0001) but not IL-6-positive areas was higher within DM, compared to nonDM valves. In DM patients, the percentage of valvular AGEs- and RAGE-positive areas correlated with HbA1c (r = 0.77, p < 0.0001 and r = 0.30, p = 0.034). Similarly, plasma AGEs and sRAGE levels were associated with HbA1c in the DM group (r = 0.32, p = 0.024 and r = 0.33, p = 0.014, respectively). In all DM patients, we found an association between the amount of valvular AGEs and the disease severity measured as aortic valve area (AVA; r = 0.68, p < 0.0001). Additionally, in DM patients with HbA1c > 7% (n = 24, 48%) we found that valvular expression of AGEs correlated with mean transvalvular pressure gradient (PGmean; r = 0.45, p = 0.027). Plasma AGEs levels in the whole DM group correlated with AVA (r = - 0.32, p = 0.02), PGmean (r = 0.31, p = 0.023), and PGmax (r = 0.30, p = 0.03). CONCLUSIONS: Our study suggests that poorly-controlled diabetes leads to increased AGEs and RAGE valvular accumulation, which at least partially, might result in AS progression in DM patients.


Asunto(s)
Estenosis de la Válvula Aórtica/sangre , Válvula Aórtica/metabolismo , Diabetes Mellitus Tipo 2/sangre , Productos Finales de Glicación Avanzada/sangre , Anciano , Válvula Aórtica/diagnóstico por imagen , Estenosis de la Válvula Aórtica/complicaciones , Estenosis de la Válvula Aórtica/diagnóstico por imagen , Biomarcadores/sangre , Diabetes Mellitus Tipo 2/complicaciones , Diabetes Mellitus Tipo 2/diagnóstico , Progresión de la Enfermedad , Femenino , Humanos , Masculino , Estudios Prospectivos , Receptor para Productos Finales de Glicación Avanzada/sangre , Índice de Severidad de la Enfermedad
8.
J Card Surg ; 35(12): 3458-3464, 2020 Dec.
Artículo en Inglés | MEDLINE | ID: mdl-32939852

RESUMEN

OBJECTIVES: Percutaneous left atrial appendage (LAA) occlusion (LAAO) is a procedure dominated by cardiologists. The aim of our study was to present the results of percutaneous LAAO performed solely by cardiac surgeons. METHODS: Two hundred twenty-three consecutive patients with nonvalvular atrial fibrillation underwent percutaneous LAAO in two cardiac surgery sites. In the first center, all 84 LAAO procedures were performed with the endocardial LAA occluders: 60 cases with the Amulet and 24 cases with the LAmbre. In the second center, all 139 LAAO procedures were performed with the LARIAT epicardial device. RESULTS: The mean CHA2 DS2 -VASc-score was 3.7 ± 1.8 points, and mean HAS-BLED score was 3.6 ± 1.2 points. The procedure was successful in 97.3% of cases. Procedural or device-related adverse events were noted in 4.4% (n = 10) of cases: one periprocedural cardiac arrest, one aortic injury, one gastrointestinal bleeding, three cases of vascular access complications, and four cardiac tamponades. After a follow-up of 40.3 ± 17.3 months, 78.4% of patients were alive, with the annual mortality rate of 5.3%. Compared to the predicted risk, the observed incidence of thromboembolism was lower by 71%, and the bleeding incidence was lower by 69%. CONCLUSIONS: Percutaneous LAAO procedures can be safely performed by cardiac surgeons, with no cardiological assistance. LAAO done by surgeons is safe and effective, and periprocedural and long-term outcomes are excellent. Cardiac surgeons should be trained in both types of LAAO: endocardial and epicardial.


Asunto(s)
Apéndice Atrial , Fibrilación Atrial , Dispositivo Oclusor Septal , Accidente Cerebrovascular , Cirujanos , Apéndice Atrial/diagnóstico por imagen , Apéndice Atrial/cirugía , Fibrilación Atrial/cirugía , Cateterismo Cardíaco , Humanos , Accidente Cerebrovascular/epidemiología , Accidente Cerebrovascular/etiología , Accidente Cerebrovascular/prevención & control , Resultado del Tratamiento
9.
J Thromb Thrombolysis ; 46(2): 193-202, 2018 Aug.
Artículo en Inglés | MEDLINE | ID: mdl-29855781

RESUMEN

Valvular heart disease is associated with an increased thromboembolic risk. Impaired fibrinolysis was reported in severe aortic stenosis (AS). Little is known about fibrinolysis in mitral stenosis (MS). We sought to compare fibrinolysis impairment in AS and MS. We studied 121 individuals scheduled for elective aortic valve (AV) or mitral valve (MV) surgery for AS (n = 76) or MS (n = 45), in order to compare fibrinolysis impairment. Fibrinolytic capacity was assessed by determination of clot lysis time (t50%) and fibrinolysis inhibitors, including plasma plasminogen activator inhibitor-1 (PAI-1) antigen (PAI-1:Ag) and activity, thrombin-activatable fibrinolysis inhibitor (TAFI) antigen and activity. Prolonged t50% (+ 29%), elevated TAFI activity (+ 12%), TAFI:Ag (+ 21%), and PAI-1:Ag (+ 84%) were observed in patients with MS, compared with those with AS. t50% Correlated with mean and maximal MV gradients (r = 0.43, p < 0.0001 and r = 0.39, p < 0.0001, respectively), but not with AV gradients. Mean and maximal MV gradients correlated with TAFI activity and PAI:Ag. Patients with permanent atrial fibrillation (AF; 35 with MS and 5 with AS) had longer t50% (by 22%, p = 0.0002) and higher PAI-1:Ag (by 74%, p < 0.0001) than the remainder. In the whole group, postoperative drainage volumes correlated inversely with PAI-1:Ag (r = - 0.22, p = 0.02). MS is associated with more pronounced impairment of global fibrinolytic capacity than AS at the stage of surgical intervention, which is in part driven by AF. Our findings suggest that hypofibrinolysis might be implicated in the progression of MS and its thromboembolic complications.


Asunto(s)
Estenosis de la Válvula Aórtica/fisiopatología , Fibrinólisis , Estenosis de la Válvula Mitral/fisiopatología , Anciano , Estenosis de la Válvula Aórtica/cirugía , Fibrilación Atrial , Carboxipeptidasa B2 , Progresión de la Enfermedad , Tiempo de Lisis del Coágulo de Fibrina , Humanos , Persona de Mediana Edad , Estenosis de la Válvula Mitral/complicaciones , Estenosis de la Válvula Mitral/cirugía , Inactivadores Plasminogénicos , Tromboembolia/etiología
10.
J Chem Phys ; 149(14): 144702, 2018 Oct 14.
Artículo en Inglés | MEDLINE | ID: mdl-30316254

RESUMEN

We have utilized scanning tunneling microscopy (STM) and low energy electron diffraction to determine the structural properties of two types of metal-phthalocyanines (MPcs), i.e., cobalt-phthalocyanine (CoPc) and hexadecafluorinated copper-phthalocyanine (F16CuPc) on the Ag(100) surface. For coverage close to one monolayer, both systems form long-range ordered structures with square unit cells. The size and rotation of the unit cell with respect to the silver lattice depend on the chemical composition of MPc. Both types of molecules prefer adsorption with around a 30° angle between the molecular axis and the [011] silver direction. The CoPcs mainly arrange in a (5 × 5)R0 phase; however, two additional local arrangements, a 26 × 26 R 1 1 ○ and a (7 × 7)R0, were detected by STM. The F16CuPcs form a 29 × 29 R 2 2 ○ structure. The co-adsorption of CoPc and F16CuPc on the Ag(100) surface in a 1:1 ratio leads to the formation of a compositionally ordered chessboard-like 5 2 × 5 2 R 4 5 ○ structure. During filled states imaging, the different appearance of the central part of each MPc allows us to distinguish CoPcs from F16CuPcs. Regardless of the applied voltage polarity, the ligands of F16CuPcs appear brighter than the ligands of CoPcs.

11.
Circ J ; 81(7): 1043-1050, 2017 Jun 23.
Artículo en Inglés | MEDLINE | ID: mdl-28344201

RESUMEN

BACKGROUND: Valve calcification is well estimated by ex-vivo micro-computed tomography (micro-CT). The objective of this study was to investigate the associations between micro-CT findings and biological indices of calcification in aortic stenosis (AS), as well as differences between bicuspid aortic valve (BAV) and tricuspid aortic valve (TAV).Methods and Results:Aortic valves and plasma were obtained from patients undergoing valve surgery. Valves were dissected and underwent micro-CT, genetic analyses, and calcium content assessment. Plasma levels of calcification markers were measured. Forty-two patients with isolated severe AS, including 22 with BAV, were studied. BAV patients had a lower median CT value (140.0 [130.0-152.0] vs. 157.0 [147.0-176.0], P=0.002) and high-density calcification (HDC) fraction (9.3 [5.7-23.3] % vs. 21.3 [14.3-31.2] %, P=0.01), as compared with TAV. Calcification fraction (CF) correlated with AS severity (measured as maximal transvalvular pressure gradient [r=0.34, P=0.03], maximal flow velocity [r=0.38, P=0.02], and indexed aortic valve area [r=-0.37, P=0.02]). For TAV patients only, mRNA expression of integrin-binding sialoprotein correlated with CF (r=0.45, P=0.048), and the receptor activator of the nuclear factor κ-B ligand transcript correlated with HDC corrugation (r=0.54, P=0.01). CONCLUSIONS: TAV patients with AS present more mineralized calcifications in micro-CT than BAV subjects. The relative volume of calcifications increases with the AS severity. In TAV patients, upregulated expression of genes involved in osteoblastogenesis in AS correlates with leaflet mineralization in micro-CT.


Asunto(s)
Estenosis de la Válvula Aórtica , Sialoproteína de Unión a Integrina/biosíntesis , Válvula Mitral , Ligando RANK/biosíntesis , Válvula Tricúspide , Calcificación Vascular , Microtomografía por Rayos X , Anciano , Estenosis de la Válvula Aórtica/diagnóstico por imagen , Estenosis de la Válvula Aórtica/metabolismo , Femenino , Regulación de la Expresión Génica , Humanos , Masculino , Persona de Mediana Edad , Válvula Mitral/diagnóstico por imagen , Válvula Mitral/metabolismo , Válvula Tricúspide/diagnóstico por imagen , Válvula Tricúspide/metabolismo , Calcificación Vascular/diagnóstico por imagen , Calcificación Vascular/metabolismo
12.
J Card Surg ; 32(1): 14-25, 2017 Jan.
Artículo en Inglés | MEDLINE | ID: mdl-27910136

RESUMEN

Mitral valve disruption is a rare but serious complication of MitraClip insertion. This review provides an update on surgical interventions following MitraClip failure, and discusses possible valve injuries and surgical approaches.


Asunto(s)
Procedimientos Quirúrgicos Cardíacos/métodos , Prótesis Valvulares Cardíacas , Insuficiencia de la Válvula Mitral/cirugía , Válvula Mitral/cirugía , Anciano , Cateterismo Cardíaco , Humanos , Masculino
13.
J Clin Monit Comput ; 31(6): 1299-1304, 2017 Dec.
Artículo en Inglés | MEDLINE | ID: mdl-28013421

RESUMEN

Fast and accurate measurement of core body temperature is crucial for accidental hypothermia treatment. We have developed a novel light and small adapter to the headset jack of a mobile phone based on Android. It has been applied to measure temperature and set up automatic notifications (e.g. Global Positioning System coordinates to emergency services dispatcher, ECMO coordinator). Its validity was confirmed in comparison with Vital Signs Monitor Spacelabs Healthcare Elance 93300 as a reference method, in a series of 260 measurements in the temperature range of 10-42 °C. Measurement repeatability was verified in a battery of 600 measurements (i.e. 100 readings at three points of 10, 25, 42 °C for both esophageal and tympanic catheters). Inter-method difference of ≤0.5 °C was found for 98.5% for esophageal catheter and 100% for tympanic catheter measurements, with concordance correlation coefficient of 0.99 for both. The readings were almost completely repeatable with water bath measurements (difference of ≤0.5 °C in 10 °C: 100% for both catheters; in 25 °C: 99% for esophageal catheter and 100% tympanic catheter; in 42 °C: 100% for both catheters). This lightweight adapter attached to smartphone and standard disposable probes is a promising tool to be applied on-site for temperature measurement in patients at risk of hypothermia.


Asunto(s)
Temperatura Corporal , Monitoreo Fisiológico/instrumentación , Teléfono Inteligente , Cateterismo , Diseño de Equipo , Humanos , Hipotermia/diagnóstico , Sistemas de Atención de Punto , Reproducibilidad de los Resultados , Procesamiento de Señales Asistido por Computador , Termómetros , Membrana Timpánica , Signos Vitales
14.
J Thromb Thrombolysis ; 42(2): 212-7, 2016 Aug.
Artículo en Inglés | MEDLINE | ID: mdl-27256342

RESUMEN

Pulmonary endarterectomy (PEA) is a curative therapeutic approach in patients with chronic thromboembolic pulmonary hypertension (CTEPH). The location-dependent structural differences of thrombotic material found in pulmonary arteries in CTEPH are poorly investigated. We present the case of a 47-year-old woman with antiphospholipid syndrome, diabetes mellitus and abnormal fibrin phenotype, who underwent PEA for CTEPH. Intravascular material removed bilaterally during PEA (from lobar, segmental and sub-segmental arteries) has been studied using light and scanning electron microscopy (SEM). Light microscopy showed tighter fibrous network in the portions of intraluminal thrombotic material facing the vessel wall, which contained collagen and fibrin fibers, and abundant cells. Cells, evaluated by immunostaining, were present in the whole removed material. Tissue factor expression was also observed with the highest values in the portions of intravascular material facing the vessel wall. In the main pulmonary arteries, SEM images revealed thick fibers of fibrous proteins loosly meshed and few erythrocytes and platelets between them (both dysmorphic "wedged" and fresh cells were present). In the fibrotic layers, containing mainly collagen and fibrin, removed from the lobar/segmental pulmonary arteries we found a stepwise increase in fiber density with decreasing vessel calibre, followed by denser fibrous networks composed of thinner fibers. Elastic fibers in the lobar and segmental arteries were aligned along the blood flow vector. These findings demonstrate differences in the structure of endarterectomized PEA material dependent on the vessel calibre and might contribute to understanding of CTEPH pathophysiology.


Asunto(s)
Endarterectomía , Fibrina/ultraestructura , Arteria Pulmonar/cirugía , Trombosis/patología , Células Sanguíneas , Colágeno , Tejido Elástico , Femenino , Humanos , Persona de Mediana Edad
15.
Platelets ; 25(8): 603-7, 2014.
Artículo en Inglés | MEDLINE | ID: mdl-24433129

RESUMEN

Perioperative myocardial infarction (PMI) following coronary artery bypass grafting (CABG) is associated with significant morbidity and mortality. The aim of this study was to assess platelet activation and oxidative stress in the setting of PMI in patients undergoing CABG. We studied 108 consecutive patients who stopped taking low-dose aspirin 7-10 days prior to elective isolated on- or off-pump CABG. ß-thromboglobulin (ß-TG), thromboxane B2 (TXB2) and 8-iso-prostaglandin F2α (8-iso-PGF2α), a marker of oxidative stress, were measured at the baseline and 5-7 days postoperatively. Aspirin (150 mg/d) was administered every morning since 12 hours after CABG. Mean baseline ß-TG was 58.5 ± 10.3 IU/ml, TXB2 was 143.6 ± 28.5 ng/ml and 8-iso-PGF2α was 355.2 ± 40.7 pg/ml. Postoperatively, after administration of 4-6 doses of aspirin, ß-TG increased by 16.7% and 8-iso-PGF2α increased by 17.2% 5-7 days after surgery (p = 0.005 and p < 0.001, respectively). TXB2 decreased by 99.7% to 410.3 ± 52.1 pg/ml (p < 0.001). Nine patients (8.3%) developed PMI. Baseline ß-TG and TXB2, together with postoperative ß-TG and 8-iso-PGF2α were higher in PMI patients than in the remaining subjects (all, p < 0.05). Multivariate analysis showed that baseline ß-TG (OR: 1.28; 95% CI: 1.05-1.57, p = 0.015) was the only independent predictor of PMI. In conclusion, we demonstrated that increased platelet activation and thromboxane production, observed in patients not taking aspirin till the day of CABG, contribute to the occurrence of PMI in early postoperative period.


Asunto(s)
Aspirina/uso terapéutico , Puente de Arteria Coronaria/efectos adversos , Infarto del Miocardio/diagnóstico , beta-Tromboglobulina/efectos adversos , Femenino , Humanos , Masculino , Persona de Mediana Edad , Estrés Oxidativo
16.
Mayo Clin Proc Innov Qual Outcomes ; 8(2): 143-150, 2024 Apr.
Artículo en Inglés | MEDLINE | ID: mdl-38434934

RESUMEN

Papillary fibroelastomas (PFEs) are small, slowly growing benign cardiac tumors with clinically significant risk of embolization. Surgical excision is the definitive treatment of symptomatic PFE and is conventionally performed through a median sternotomy. In this study, we report a series of 12 patients, who underwent robotic-assisted PFE removal at the Mayo Clinic. PFE involved the mitral valve, left atrium, and tricuspid valve. No major complications occurred after the procedure, and most patients were discharged 4 days after the surgery. On follow-up, 1 patient demonstrated pericarditis.

17.
J Thorac Dis ; 16(8): 5018-5030, 2024 Aug 31.
Artículo en Inglés | MEDLINE | ID: mdl-39268099

RESUMEN

Background: In the era of percutaneous aortic valve implantation, biological valves are the preferred prostheses implanted in patients undergoing surgical aortic valve replacement (sAVR). The aim was to present a real-life analysis of mid-term sAVR outcomes for the four aortic bioprostheses: the Hancock II, the Carpentier-Edwards Perimount Magna, the Carpentier-Edwards Perimount Magna Ease and the Trifecta valve. Methods: This is a retrospective study based on data from the Polish National Cardiac Surgery Database. The study population comprised of 1,589 consecutive patients, of whom 432 were in the Hancock II group, 356 in the Carpentier-Edwards Perimount Magna group, 427 in the Carpentier-Edwards Magna Ease group, and 374 in the Trifecta group. A comparison of the four groups was performed using analysis of variance (ANOVA) or Kruskal-Wallis test with appropriate post hoc tests (Tukey HSD or Steel-Dwass, respectively). Results: Patients in the Hancock II group were older, had higher New York Heart Association (NYHA) and Canadian Cardiovascular Society (CCS) classes, had lower prevalence of hypertension and hyperlipidemia but higher prevalence of diabetes. The lowest mean valve size was observed in Trifecta group and the highest was in the Magna group (P<0.001). Survival analysis showed no significant differences in in-hospital mortality: 3.9% in Hancock II, 3.1% in Perimount, 3.3% in Magna and 2.1% in Trifecta group. Five-year mortality was significantly higher in Hancock II group (25.7%) compared to the other bioprostheses: 12.1% in Perimount, 9.1% in Magna and 10.70% in Trifecta group respectively. Conclusions: The 5-year mortality rate was significantly higher in the Hancock II group compared to the other bioprostheses. In contrast, Trifecta, Perimount Magna, and Magna Ease had similar 5-year mortality rates.

19.
J Thromb Thrombolysis ; 35(1): 127-9, 2013 Jan.
Artículo en Inglés | MEDLINE | ID: mdl-23080213

RESUMEN

Pulmonary embolectomy is a treatment option in selected patients with high-risk pulmonary embolism (PE). Efficiency of thrombus degradation in PE largely depends on the architecture of its fibrin network, however little is known about its determinants. We present the case of a 56-year-old woman with high-risk PE and proximal deep-vein thrombosis, whose thrombotic material removed during embolectomy from the right atrium and pulmonary (lobar and segmental) arteries has been studied using scanning electron microscopy (SEM). SEM images showed that distally located thrombi are richer in densely-packed fibrin fibers and contain more white cells and less erythrocytes than the proximal ones and the atrial thrombus. Fibrin fibers alignment along the flow vector was observed in the thrombi removed from high-velocity flow pulmonary arteries, and not in the atrial thrombus. The content of denser fibrin network and platelet aggregates was increased in segmental thromboemboli. Our findings describe the relation between thrombus architecture and location, and might help to elucidate thrombus resistance to anticoagulant therapy in some PE patients.


Asunto(s)
Embolectomía , Fibrina/ultraestructura , Arteria Pulmonar/cirugía , Trombosis de la Vena/cirugía , Anticoagulantes , Resistencia a Medicamentos , Femenino , Atrios Cardíacos/cirugía , Humanos , Persona de Mediana Edad
20.
Platelets ; 24(2): 151-5, 2013.
Artículo en Inglés | MEDLINE | ID: mdl-22497730

RESUMEN

Patients with peripheral artery disease (PAD) following peripheral percutaneous transluminal angioplasty (PTA) with stent implantation are prone to stent thrombosis despite treatment with aspirin and clopidogrel. Impaired clopidogrel responsiveness is associated with increased risk of ischemic events in patients following coronary stent implantation. We sought to assess platelet responsiveness to clopidogrel and aspirin in patients with PAD and recurrent stent thrombosis. Platelet aggregation induced by 5 and 20 µmol/l adenosine diphosphate (ADP) and 0.5 mmol/l arachidonic acid (AA), together with platelet reactivity index (PRI) and serum thromboxane B(2) (TXB(2)), were determined in 11 patients with PAD and a history of stent thrombosis (mean, 3.1 ± 1.14) after PTA and in 15 patients with PAD with no such history, also in 11 controls with coronary artery disease (CAD) and previous stent thrombosis. Platelet aggregation to 5 µmol/l ADP was higher in subjects with PAD and stent thrombosis than in those without stent thrombosis (p = 0.0003) and CAD subjects (p = 0.002). Aggregation induced by 20 µmol/l ADP was higher in PAD group with stent thrombosis than in PAD subjects without thrombosis (p = 0.004). The PAD group with stent thrombosis had higher AA-induced platelet aggregation than CAD controls (p = 0.007) and serum TXB(2) concentrations higher than PAD group without thrombosis (p = 0.002) and CAD group (p = 0.02). Concluding, platelet responsiveness to clopidogrel and aspirin is impaired in patients with PAD and recurrent stent thrombosis following PTA, as compared with similar individuals with CAD, and PAD with no history of stent thrombosis. This indicates that atherosclerosis burden affects platelet function and might contribute to stent thrombosis following percutaneous intervention in peripheral arteries.


Asunto(s)
Aspirina/farmacología , Plaquetas/efectos de los fármacos , Plaquetas/fisiología , Resistencia a Medicamentos , Inhibidores de Agregación Plaquetaria/farmacología , Ticlopidina/análogos & derivados , Anciano , Angioplastia/efectos adversos , Aspirina/uso terapéutico , Clopidogrel , Femenino , Humanos , Masculino , Persona de Mediana Edad , Enfermedad Arterial Periférica/terapia , Agregación Plaquetaria/efectos de los fármacos , Factores de Riesgo , Stents , Trombosis/tratamiento farmacológico , Trombosis/etiología , Ticlopidina/farmacología , Ticlopidina/uso terapéutico
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA