Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 6 de 6
Filtrar
1.
J Appl Biomech ; 35(1): 19­24, 2019 02 01.
Artículo en Inglés | MEDLINE | ID: mdl-29989479

RESUMEN

Patients with peripheral artery disease (PAD) experience significant leg dysfunction. The effects of PAD on gait include shortened steps, slower walking velocity, and altered gait kinematics and kinetics, which may confound joint torques and power measurements. Spatiotemporal parameters, joint torques and powers were calculated and compared between 20 patients with PAD and 20 healthy controls using independent t-tests. Separate ANCOVA models were used to evaluate group differences after independently adjusting for gait velocity, stride length and step width. Compared to healthy controls, patients with PAD exhibited reduced peak extensor and flexor torques at the knee, and hip. After adjusting for all covariates combined, differences between groups remained for ankle power generation in late stance, and knee flexor torque. Reduced walking velocity observed in subjects affected by PAD was closely connected with reductions in joint torques and powers during gait. Gait differences remained, at the knee and ankle, after adjusting for the combined effect of spatiotemporal parameters. Improving muscle function through exercise or with the use of assistive devices needs to be a key tool in the development of interventions that aim to enhance the ability of PAD patients to restore spatiotemporal gait parameters.

2.
Entropy (Basel) ; 20(10)2018 Oct.
Artículo en Inglés | MEDLINE | ID: mdl-30853788

RESUMEN

Sample entropy (SE) has relative consistency using biologically-derived, discrete data >500 data points. For certain populations, collecting this quantity is not feasible and continuous data has been used. The effect of using continuous versus discrete data on SE is unknown, nor are the relative effects of sampling rate and input parameters m (comparison vector length) and r (tolerance). Eleven subjects walked for 10-minutes and continuous joint angles (480Hz) were calculated for each lower-extremity joint. Data were downsampled (240, 120, 60Hz) and discrete range-of-motion was calculated. SE was quantified for angles and range-of-motion at all sampling rates and multiple combinations of parameters. A differential relationship between joints was observed between range-of-motion and joint angles. Range-of-motion SE showed no difference; whereas, joint angle SE significantly decreased from ankle to knee to hip. To confirm findings from biological data, continuous signals with manipulations to frequency, amplitude, and both were generated and underwent similar analysis to the biological data. In general, changes to m, r, and sampling rate had a greater effect on continuous compared to discrete data. Discrete data was robust to sampling rate and m. It is recommended that different data types not be compared and discrete data be used for SE.

3.
J Arthroplasty ; 27(2): 305-9, 2012 Feb.
Artículo en Inglés | MEDLINE | ID: mdl-21778033

RESUMEN

A reproducible retroacetabular defect was created bilaterally in 9 cadaver pelves. The defects were filled with either an injectable, bioresorbable, calcium phosphate cement, or reverse-reamed cancellous allograft. An uncemented acetabular shell was impacted, followed by the placement of an appropriate liner. The pelves were then sectioned, and each half was loaded in a material testing machine to simulate walking on the construct over a several week period. The cement-filled defects lasted a greater number of cycles before failure and had greater cup stability and stiffness. The use of resorbable bone void filler for retroacetabular defects shows promise in this biomechanical analysis. Long-term clinical follow-up is warranted to track osseointegration of the implant and restoration of bone stock between this and other clinically accepted surgical techniques.


Asunto(s)
Acetábulo/cirugía , Artroplastia de Reemplazo de Cadera/instrumentación , Cementos para Huesos , Trasplante Óseo , Fosfatos de Calcio , Articulación de la Cadera/cirugía , Prótesis de Cadera , Inestabilidad de la Articulación/prevención & control , Implantes Absorbibles , Anciano , Anciano de 80 o más Años , Fenómenos Biomecánicos , Cadáver , Femenino , Humanos , Masculino , Falla de Prótesis , Análisis de Regresión , Reoperación/instrumentación , Trasplante Homólogo
4.
J Knee Surg ; 32(9): 872-878, 2019 Sep.
Artículo en Inglés | MEDLINE | ID: mdl-30227451

RESUMEN

Traditionally total knee arthroplasty (TKA) design has been based on theories of the movement of the healthy knee joint. Currently, there are two competing theories on the flexion/extension axis of rotation of the knee with disparate radii of rotation, and thus differing movement patterns. The purpose of our study was to compare stair ascent kinematics and kinetics of single-radius (SR) and multiradius (MR) TKA subjects. We hypothesized that the knee kinematics and kinetics of SR TKA patients would more closely replicate healthy age matched controls during stair ascent than MR TKA patients, 1 year after TKA. Both patient groups had large improvements in biomechanical and clinical outcome measures following surgical intervention. However, the SR knee design performs closer to healthy controls than MR knees during stair ascent, supporting results that have been previously obtained for level walking. SR TKA subjects demonstrated reduced power production and sagittal moment compared with controls, albeit more than MR TKA subjects. This study demonstrates that patients who receive SR TKA have kinematics more closely aligned to normal patterns postoperatively than those who received an MR TKA. The power production and sagittal moment of the healthy controls most closely match previously published values of younger adults, SR TKA group most closely matches older adults, while the MR TKA group has lower power production and sagittal moments than either previously published age group. This strongly suggests that the biomechanical differences found in this study are evidence of functional deficiencies. Further research is needed to determine how these deficiencies progress with patient aging.


Asunto(s)
Artroplastia de Reemplazo de Rodilla/métodos , Articulación de la Rodilla/fisiología , Subida de Escaleras/fisiología , Anciano , Artroplastia de Reemplazo de Rodilla/estadística & datos numéricos , Fenómenos Biomecánicos , Estudios de Casos y Controles , Femenino , Humanos , Cinética , Articulación de la Rodilla/cirugía , Prótesis de la Rodilla , Masculino , Persona de Mediana Edad , Movimiento , Periodo Posoperatorio , Rango del Movimiento Articular , Rotación , Caminata
5.
Gait Posture ; 57: 258-264, 2017 09.
Artículo en Inglés | MEDLINE | ID: mdl-28683417

RESUMEN

OBJECTIVE: Previous studies have indicated that patients with peripheral artery disease (PAD), display significant differences in their kinetic and kinematic gait characteristics when compared to healthy, aged-matched controls. The ability of patients with chronic obstructive pulmonary disease (COPD) to ambulate is also limited. These limitations are likely due to pathology-driven muscle morphology and physiology alterations establish in PAD and COP, respectively. Gait changes in PAD were compared to gait changes due to COPD to further understand how altered limb muscle due to disease can alter walking patterns. Both groups were independently compared to healthy controls. It was hypothesized that both patients with PAD and COPD would demonstrate similar differences in gait when compared to healthy controls. METHODS: Patients with PAD (n=25), patients with COPD (n=16), and healthy older control subjects (n=25) performed five walking trials at self-selected speeds. Sagittal plane joint kinematic and kinetic group means were compared. RESULTS: Peak values for hip flexion angle, braking impulse, and propulsive impulse were significantly reduced in patients with symptomatic PAD compared to patients with COPD. After adjusting for walking velocity, significant reductions (p<0.05) in the peak values for hip flexion angle, dorsiflexor moment, ankle power generation, propulsion force, braking impulse, and propulsive impulse were found in patients with PAD compared to healthy controls. No significant differences were observed between patients with COPD and controls. CONCLUSIONS: The results of this study demonstrate that while gait patterns are impaired for patients with PAD, this is not apparent for patients with COPD (without PAD). PAD (without COPD) causes changes to the muscle function of the lower limbs that affects gait even when subjects walk from a fully rested state. Altered muscle function in patients with COPD does not have a similar effect.


Asunto(s)
Marcha/fisiología , Enfermedad Arterial Periférica/fisiopatología , Enfermedad Pulmonar Obstructiva Crónica/fisiopatología , Adulto , Anciano , Articulación del Tobillo/fisiopatología , Fenómenos Biomecánicos , Estudios de Casos y Controles , Articulación de la Cadera/fisiopatología , Humanos , Cinética , Persona de Mediana Edad , Rango del Movimiento Articular
6.
Rehabil Res Pract ; 2015: 124023, 2015.
Artículo en Inglés | MEDLINE | ID: mdl-26770826

RESUMEN

Accumulating evidence suggests revascularization of peripheral arterial disease (PAD) limbs results in limited improvement in functional gait parameters, suggesting underlying locomotor system pathology. Spatial and temporal (ST) gait parameters are well studied in patients with PAD at baseline and are abnormal when compared to controls. The purpose of this study was to systematically review and critically analyze the available data on ST gait parameters before and after interventions. A full review of literature was conducted and articles were included which examined ST gait parameters before and after intervention (revascularization and exercise). Thirty-three intervention articles were identified based on 154 articles that evaluated ST gait parameters in PAD. Four articles fully assessed ST gait parameters before and after intervention and were included in our analysis. The systematic review of the literature revealed a limited number of studies assessing ST gait parameters. Of those found, results demonstrated the absence of improvement in gait parameters due to either exercise or surgical intervention. Our study demonstrates significant lack of research examining the effectiveness of treatments on ST gait parameters in patients with PAD. Based on the four published articles, ST gait parameters failed to significantly improve in patients with PAD following intervention.

SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA