1.
J Clin Invest ; 82(5): 1661-9, 1988 Nov.
Artículo en Inglés | MEDLINE | ID: mdl-3183060

RESUMEN

Previous reports have shown that increases in heart rate may result in enhanced left ventricular (LV) systolic and diastolic performance. To assess whether this phenomenon occurs in the presence of depressed LV function, the effects of pacing on LV pressure and volume were compared in seven patients with dilated cardiomyopathy (LV ejection fraction 0.19 +/- 0.11) and six patients with no or minimal coronary artery disease (LV ejection fraction 0.69 +/- 0.11). Patients with normal LV function demonstrated significant increases in LV peak-positive dP/dt, LV end-systolic pressure-volume ratio, LV peak filling rate, and a progressive leftward and downward shift of their pressure-volume diagrams, compatible with increased contractility and distensibility in response to pacing tachycardia. There was no change in LV peak-negative dP/dt or tau. Patients with dilated cardiomyopathy, in contrast, demonstrated no increase in either LV peak-positive dP/dt or the end-systolic pressure-volume ratio, and absence of a progressive leftward shift of their pressure-volume diagrams. Moreover, cardiomyopathy patients demonstrated no increase in LV peak-negative dP/dt or LV peak filling rate and a blunted downward shift of the diastolic limb of their pressure-volume diagrams. Tau, as determined from a derivative method, became abbreviated although never reaching control values. We conclude that patients with dilated cardiomyopathy may demonstrate little or no significant enhancement in systolic and diastolic function during atrial pacing tachycardia, suggesting a depression of both inotropic and lusitropic reserve.


Asunto(s)
Estimulación Cardíaca Artificial , Cardiomiopatía Dilatada/fisiopatología , Taquicardia/fisiopatología , Gasto Cardíaco , Diástole , Femenino , Atrios Cardíacos/fisiopatología , Humanos , Masculino , Persona de Mediana Edad , Volumen Sistólico , Sístole
2.
J Am Coll Cardiol ; 17(2): 485-91, 1991 Feb.
Artículo en Inglés | MEDLINE | ID: mdl-1991907

RESUMEN

Between December 1, 1986 and October 30, 1987, balloon aortic valvuloplasty was performed in 492 patients with aortic stenosis (mean age 79 +/- 8.4 years) enrolled in the Mansfield Scientific Aortic Valvuloplasty Registry. All procedures were performed from a femoral approach (92%), brachial approach (6%) or transseptal approach (2%) and utilized either a single balloon technique (72%) or a double balloon technique (28%). Valvuloplasty resulted in a significant improvement in aortic valve area (0.50 +/- 0.18 cm2 to 0.82 +/- 0.30 cm2), mean aortic valve gradient (60 +/- 23 mm Hg to 30 +/- 13 mm Hg) and cardiac output (3.86 +/- 1.26 to 4.05 +/- 1.31 liters/min). Serial aortography demonstrated a moderate or severe increase in aortic insufficiency in only 2.1% of patients. Statistical analysis of the procedural factors affecting acute valvuloplasty results demonstrated significant correlations of single versus double balloon technique, total number of balloon inflations and total number of balloon exchanges with respect to the absolute change in mean aortic valve gradient occurring during the valvuloplasty procedure. In addition, there was a significant correlation between the maximal time of valvuloplasty balloon inflation with aortic valve area measured after valvuloplasty, and there were significant correlations of the total number of balloon inflations and total number of balloon exchanges with the aortic valve mean gradient measured after valvuloplasty. The overall complication rate for the procedure was 20.5%, including vascular injury in 11%, embolic phenomenon in 2.2%, ventricular perforation resulting in tamponade in 1.8%, massive aortic insufficiency in 1%, nonfatal arrhythmia in 0.8% and myocardial infarction in 0.2%.(ABSTRACT TRUNCATED AT 250 WORDS)


Asunto(s)
Estenosis de la Válvula Aórtica/terapia , Oclusión con Balón , Cateterismo/efectos adversos , Hemodinámica/fisiología , Anciano , Insuficiencia de la Válvula Aórtica/etiología , Taponamiento Cardíaco/etiología , Cateterismo/métodos , Embolia/etiología , Femenino , Lesiones Cardíacas/etiología , Humanos , Masculino , Sistema de Registros , Factores de Riesgo
3.
J Am Coll Cardiol ; 10(1): 115-24, 1987 Jul.
Artículo en Inglés | MEDLINE | ID: mdl-2955015

RESUMEN

Echocardiographic studies, adequate for analysis of aortic valve area using the continuity equation, were obtained in 31 patients aged greater than or equal to 60 years who were undergoing catheterization for assessment of suspected aortic stenosis. Catheterization-determined aortic valve area was 0.74 +/- 0.30 cm2 (mean +/- SD) and Doppler-determined aortic valve areas were 0.68 +/- 0.27 and 0.65 +/- 0.27 cm2, depending on whether peak or mean velocities, respectively, were entered into the continuity equation. There were significant correlations between both of the Doppler-derived and the catheterization-determined aortic valve areas (r = 0.86, p less than 0.001 for both the continuity equation employing peak velocities and the continuity equation employing mean velocities) which were demonstrated to be linear by F test (catheterization area = -0.03 + 1.13 X Doppler area determined using peak velocities, SEE = 0.163 cm2, p less than 0.001; and catheterization area = -0.02 + 1.16 X Doppler area determined using mean velocities, SEE = 0.165 cm2, p less than 0.001). Both sets of correlations had linear regression parameters meeting the conditions for identity. Significant linear correlations were also noted between the non-invasive measurements of aortic valve excursion, ventricular ejection time, time to one-half carotid upstroke, maximal Doppler velocity and maximal Doppler gradient and catheterization aortic valve area, but the correlations were less tight than those between valve areas determined by catheterization and by Doppler continuity equation. Ten of the patients underwent percutaneous balloon aortic valvuloplasty. There were significant linear correlations between aortic valve areas determined by Doppler and catheterization methods both before valvuloplasty (r = 0.77, p = 0.01; p less than 0.001 by F test, SEE = 0.134 cm2) and after valvuloplasty (r = 0.85, p less than 0.01; p = 0.0001 by F test, SEE = 0.161 cm2). Linear regression parameters met the conditions for identity. There was also a significant linear correlation between catheterization and Doppler measurements of absolute change in aortic valve area (r = 0.79, p less than 0.01; p less than 0.001 by F test, SEE = 0.11 cm2). Aortic valve area can be determined reliably by continuity equation in elderly patients. In addition, results of balloon valvuloplasty, measured by changes in catheterization-determined aortic valve area, are accurately reflected by changes in aortic valve area determined using the continuity equation.


Asunto(s)
Envejecimiento/fisiología , Angioplastia de Balón , Estenosis de la Válvula Aórtica/terapia , Válvula Aórtica/patología , Ecocardiografía , Anciano , Anciano de 80 o más Años , Válvula Aórtica/fisiopatología , Estenosis de la Válvula Aórtica/patología , Estenosis de la Válvula Aórtica/fisiopatología , Cateterismo Cardíaco , Ecocardiografía/métodos , Femenino , Humanos , Masculino , Persona de Mediana Edad , Estudios Prospectivos , Pulso Arterial
4.
J Am Coll Cardiol ; 11(6): 1213-8, 1988 Jun.
Artículo en Inglés | MEDLINE | ID: mdl-3366995

RESUMEN

Six patients with severe combined aortic and mitral valve stenosis underwent double valve balloon dilation as an alternative to surgical valve replacement. Cardiac catheterization in all patients before valve dilation revealed heavily calcified aortic and mitral valves with severe stenosis and minimal regurgitation. Balloon aortic valvuloplasty was performed in each patient with a 20 mm balloon dilation catheter passed retrograde through the aortic valve whereas mitral valvuloplasty was performed transseptally with either a single or double balloon technique. After dilation, the mean aortic and mitral gradients decreased in all patients, with the area of the aortic and the mitral valve increasing from 0.5 +/- 0.3 to 0.9 +/- 0.3 cm2 and from 0.7 +/- 0.1 to 1.5 +/- 0.7 cm2, respectively. The procedures were well tolerated, with no embolic events and no significant increase in valvular regurgitation, and resulted in a reduction in symptoms of dyspnea on exertion and weakness in all patients that has persisted for an average of 5.7 months of follow-up in five of the six patients. It is concluded that combined dilation of stenotic aortic and mitral valves can be accomplished percutaneously and may be considered for patients with combined valvular stenosis who refuse or are deferred from surgical intervention.


Asunto(s)
Estenosis de la Válvula Aórtica/terapia , Cateterismo/métodos , Estenosis de la Válvula Mitral/terapia , Anciano , Anciano de 80 o más Años , Estenosis de la Válvula Aórtica/complicaciones , Presión Sanguínea , Gasto Cardíaco , Femenino , Estudios de Seguimiento , Humanos , Masculino , Persona de Mediana Edad , Estenosis de la Válvula Mitral/complicaciones
5.
J Am Coll Cardiol ; 11(1): 12-9, 1988 Jan.
Artículo en Inglés | MEDLINE | ID: mdl-3335689

RESUMEN

Dilation of the left ventricle after myocardial infarction is common, occurs rapidly (within 2 weeks of infarction) and may be self-limited. To evaluate the time course of postinfarction left ventricular dilation and to assess the impact of successful coronary thrombolysis, serial radionuclide left ventricular volume analyses were performed in 36 patients undergoing attempted thrombolysis for acute transmural myocardial infarction. All patients underwent cardiac catheterization, coronary angiography and attempted thrombolysis within 7 h of the onset of symptoms. The site of coronary occlusion was the left anterior descending coronary artery in 17 patients, the right coronary artery in 18 and, in 1 patient, occluded bypass grafts to the right and left circumflex coronary arteries. Attempted reperfusion using a thrombolytic agent was successful in 22 individuals, occurring 5 +/- 1 h after the onset of symptoms. Gated radionuclide ventriculography was performed early (mean time 1 day after admission, n = 36), subacutely (mean time 11 days postinfarction, n = 36) and late after infarction (mean time 10.5 months, n = 25), and a geometric technique was used to measure serial left ventricular end-diastolic volume. Left ventricular end-diastolic volume for the entire group increased significantly (p less than 0.01) from 153 +/- 30 ml at baseline to 172 +/- 45 ml (at 11 days) to 220 +/- 63 ml (at 10.5 months). Twenty of 36 patients showed greater than 20% increase in left ventricular end-diastolic volume (dilation) with time. This appeared early in seven patients, occurred remote from infarction in seven others and showed a progressive pattern in six.(ABSTRACT TRUNCATED AT 250 WORDS)


Asunto(s)
Vasos Coronarios/patología , Fibrinolíticos/uso terapéutico , Infarto del Miocardio/patología , Adulto , Anciano , Dilatación Patológica/patología , Femenino , Corazón/diagnóstico por imagen , Ventrículos Cardíacos/patología , Humanos , Masculino , Persona de Mediana Edad , Infarto del Miocardio/tratamiento farmacológico , Cintigrafía , Volumen Sistólico , Factores de Tiempo
6.
J Am Coll Cardiol ; 12(6): 1400-6, 1988 Dec.
Artículo en Inglés | MEDLINE | ID: mdl-2973480

RESUMEN

Data from 2,883 cardiac catheterizations performed during an 18 month period (from July 1986 through December 1987) were analyzed to assess the current complication profile of diagnostic and therapeutic procedures. Procedures performed during the study period included 1,609 diagnostic catheterizations, 933 percutaneous transluminal coronary angioplasties and 199 percutaneous balloon valvuloplasties. Overall, the mortality rate was 0.28% but ranged from 0.12% for diagnostic catheterizations to 0.3% for coronary angioplasty and 1.5% for balloon valvuloplasty. Emergency cardiac surgery was required in 12 angioplasty patients (1.2%). Cardiac perforation occurred in seven patients (0.2%), of whom six were undergoing valvuloplasty, and five (2.5% of valvuloplasty attempts) required emergency surgery for correction. Local vascular complications requiring operative repair occurred in 1.9% of patients overall, ranging from 1.6% for diagnostic catheterization to 1.5% for angioplasty and 7.5% for valvuloplasty. Although the complication rates for diagnostic catheterization compare favorably with those of previous multicenter registries, current overall complication rates are significantly higher because of the performance of therapeutic procedures with greater intrinsic risk and the inclusion of increasingly aged and acutely ill or unstable patients.


Asunto(s)
Cateterismo Cardíaco/efectos adversos , Anciano , Anciano de 80 o más Años , Angioplastia de Balón/efectos adversos , Cateterismo/efectos adversos , Enfermedad Coronaria/terapia , Humanos , Persona de Mediana Edad
7.
J Am Coll Cardiol ; 7(6): 1410-5, 1986 Jun.
Artículo en Inglés | MEDLINE | ID: mdl-3711499

RESUMEN

A 75 year old man with long-standing rheumatic mitral stenosis who refused surgical intervention was treated with percutaneous balloon valvuloplasty. Prevalvuloplasty evaluation revealed a heavily calcified mitral valve, a mean transvalvular gradient of 18 mm Hg, a Fick cardiac index of 1.7 liters/min per m2, a mitral valve area of 0.6 cm2 and 1 + mitral regurgitation. After transeptal catheterization and balloon dilation of the interatrial septum with an 8 mm angioplasty balloon, a 25 mm valvuloplasty balloon was advanced over a guide wire across the interatrial septum and positioned across the mitral anulus. Subsequent balloon inflation at 3 atm pressure resulted in a reduction of the mean mitral valve gradient to 12 mm Hg, an increase in cardiac index to 2.5 liters/min per m2, an increase in mitral valve area in 1.4 cm2 and an increase in mitral regurgitation from 1 + to 2 +. Valvuloplasty was well tolerated without embolization of clot or valvular debris, and resulted in marked clinical improvement with decreased dyspnea and increased exercise tolerance. Repeat catheterization 2 months after valvuloplasty showed further resolution of pulmonary hypertension and no evidence of valvular restenosis or worsening mitral regurgitation, but detected a small atrial septal defect with a pulmonary to systemic blood flow ratio of 1.8. It is concluded that percutaneous valvuloplasty is possible in the adult patient with calcific rheumatic mitral stenosis, and may result in a significant improvement in valvular function without producing life-threatening complications.


Asunto(s)
Calcinosis/terapia , Estenosis de la Válvula Mitral/terapia , Cardiopatía Reumática/terapia , Anciano , Dilatación/métodos , Humanos , Masculino
8.
J Am Coll Cardiol ; 13(3): 630-6, 1989 Mar 01.
Artículo en Inglés | MEDLINE | ID: mdl-2918169

RESUMEN

Assessment of the complex relations between pressure and volume in the right atrium has been hampered in the past by difficulties in the measurement of atrial volume. Accordingly, in the present study the dynamics of right atrial pressure-volume relations were examined (with the use of an impedance catheter to measure right atrial volume) in patients with and without an atrial septal defect. Right atrial pressure and impedance volume were measured in 16 patients at the time of cardiac catheterization with the use of a multi-electrode impedance catheter to provide continuous, on-line, pressure-volume data. Eleven patients without evidence of an interatrial shunt were examined during normal respiration and during the Valsalva maneuver and contrasted with five patients with an atrial septal defect documented by oxygen saturation step-up and echocardiographic studies. Right atrial pressure-volume diagrams in patients without an atrial septal defect exhibited the normal figure eight pattern, with an A loop (atrial contraction) and a V loop (passive filling), corresponding to the A wave and V wave of right atrial pressure, respectively. During inspiration, mean right atrial pressure decreased and mean right atrial volume increased, consistent with augmented venous return. With the Valsalva maneuver, right atrial pressure increased and both right atrial stroke volume and mean right atrial volume decreased compared with baseline. Patients with an atrial septal defect demonstrated baseline pressure-volume diagrams similar to those of patients without an interatrial shunt. However, no change in mean right atrial volume occurred with either respiration or the Valsalva maneuver despite changes in right atrial pressure similar to those seen inpatients without an atrial septal defect.(ABSTRACT TRUNCATED AT 250 WORDS)


Asunto(s)
Función Atrial , Defectos del Tabique Interatrial/fisiopatología , Adulto , Volumen Cardíaco , Cardiografía de Impedancia , Ecocardiografía , Femenino , Atrios Cardíacos/anatomía & histología , Atrios Cardíacos/fisiopatología , Humanos , Masculino , Persona de Mediana Edad , Monitoreo Fisiológico , Presión , Valores de Referencia , Respiración , Maniobra de Valsalva
9.
J Am Coll Cardiol ; 24(1): 247-53, 1994 Jul.
Artículo en Inglés | MEDLINE | ID: mdl-8006273

RESUMEN

OBJECTIVES: This study was designed to assess the feasibility of calculating left ventricular volumes using intracardiac ultrasound. BACKGROUND: Previous studies have validated transthoracic echocardiographic determinations of left ventricular volumes and have indicated the superiority of Simpson rule reconstruction algorithms. The feasibility of imaging the left ventricle with intracardiac ultrasound has also been demonstrated. METHODS: The determination of left ventricular volumes with Simpson rule reconstruction of intracardiac ultrasound images was evaluated in two phases. In vitro validation was performed in 29 animal hearts preserved in either a nondistended or distended state. Latex cast volumes were the reference standard. In vivo studies used 14 pigs, and compared intracardiac ultrasound volumes and ejection fraction with single-plane contrast angiographic values. A 12.5-MHz device was used to record short-axis images at 0.5-cm intervals. These were used to reconstruct the ventricle as a stack of cylindric elements using all imaged levels as well as sections recorded every 1 and 2 cm and at a single midventricular level. RESULTS: In the in vitro hearts, when all recorded sections were used, there was excellent agreement between intracardiac ultrasound and latex cast volumes (intracardiac ultrasound volume = 0.89 latex cast volume + 2.22, r = 0.95; intracardiac ultrasound volume = 0.97 latex cast volume + 0.91, r = 0.99) for nondistended and distended hearts, respectively. In vivo, there was again close correspondence between ultrasound and angiographic volumes (intracardiac ultrasound volume = 1.04 angiographic volume - 3.6, r = 0.91). The relation between intracardiac ultrasound and angiographic ejection fraction was fair (intracardiac ultrasound ejection fraction = 1.00 angiographic ejection fraction + 6.85, r = 0.69). Excellent correlations for the volumes were maintained as the number of cross sections was reduced to those recorded every 1 and 2 cm (r = 0.87 to 0.99). With a single midventricular site more variable but generally good correlations were obtained (r = 0.77 to 0.99). CONCLUSIONS: The application of Simpson rule reconstruction to short-axis images of the left ventricle obtained with intracardiac ultrasound provides accurate determination of left ventricular volumes in animal hearts. This technique may prove useful in the analysis of left ventricular structure and function.


Asunto(s)
Ecocardiografía/métodos , Algoritmos , Animales , Bovinos , Ecocardiografía/instrumentación , Ecocardiografía/estadística & datos numéricos , Estudios de Factibilidad , Ventrículos Cardíacos/diagnóstico por imagen , Técnicas In Vitro , Variaciones Dependientes del Observador , Reproducibilidad de los Resultados , Porcinos
10.
J Am Coll Cardiol ; 12(3): 642-8, 1988 Sep.
Artículo en Inglés | MEDLINE | ID: mdl-2969927

RESUMEN

Pressure overload hypertrophy of the left ventricle due to aortic stenosis is associated with abnormalities of left ventricular isovolumic relaxation and early diastolic filling. The relative contribution of the hemodynamic load on the left ventricle to the impairment of diastolic function observed in this disorder remains poorly understood. To study this relation, the vasodilator nitroprusside was administered to eight patients with aortic stenosis and normal systolic function. The effect of a short-term reduction in left ventricular preload and afterload on left ventricular isovolumic relaxation and early diastolic filling was assessed by analysis of simultaneous micromanometer left ventricular pressure and radionuclide angiographic volume measurements. At baseline, left ventricular systolic and end-diastolic pressures were markedly elevated, and associated with prolongation of the time constant of left ventricular relaxation and depression of the left ventricular peak filling rate. Infusion of nitroprusside resulted in reduction of left ventricular systolic (204 +/- 31 to 176 +/- 31 mm Hg, p less than 0.05) and end-diastolic (31 +/- 8 to 18 +/- 6 mm Hg, p less than 0.05) pressures, with no associated improvement in time constant of left ventricular pressure decay (T) (68 +/- 25 to 80 +/- 37 ms, p = NS), T 1/2 (34 +/- 8 to 34 +/- 14 ms, p = NS), left ventricular peak filling rate (2.3 +/- 0.5 to 2.3 +/- 0.8 end-diastolic volume/s, p = NS) or time to left ventricular peak filling rate (150 +/- 50 to 144 +/- 37 ms, p = NS).(ABSTRACT TRUNCATED AT 250 WORDS)


Asunto(s)
Estenosis de la Válvula Aórtica/fisiopatología , Corazón/fisiopatología , Contracción Miocárdica , Anciano , Presión Sanguínea/efectos de los fármacos , Cardiomegalia/fisiopatología , Diástole/efectos de los fármacos , Ventrículos Cardíacos/fisiopatología , Humanos , Persona de Mediana Edad , Contracción Miocárdica/efectos de los fármacos , Nitroprusiato/farmacología , Volumen Sistólico/efectos de los fármacos
11.
J Am Coll Cardiol ; 8(5): 1152-60, 1986 Nov.
Artículo en Inglés | MEDLINE | ID: mdl-3760389

RESUMEN

The end-systolic pressure-volume relation has been postulated as a load-independent measure of cardiac contractility, but has been difficult to measure because of technical problems associated with the serial measurement of intracardiac volume over a physiologic range of ventricular loading conditions. Utilizing a multielectrode impedance catheter to assess continuous, on-line left ventricular relative volume during transient inferior vena cava occlusion, a method is described for determining the end-systolic pressure-volume relation and for assessing changes in this relation secondary to inotropic modulation. In particular, using this method, the relative inotropic properties were determined of four drugs: dobutamine, milrinone, epinephrine and an experimental cardiotonic agent (Ro 13-6438, Posicor). Left ventricular micromanometer pressure and impedance catheter volume were measured continuously in 10 open chest, anesthetized dogs and 14 pigs. Arterial pressure was altered over a range of 20 to 60 mm Hg by brief inferior vena cava constriction. A linear end-systolic pressure-volume relation was observed in pressure-volume diagrams constructed from on-line pressure and impedance catheter recordings. Administration of dobutamine, milrinone and epinephrine resulted in a leftward shift and an increase in the slope of the end-systolic pressure-volume relation as compared with baseline; Posicor did not alter the slope over a range of doses, despite an increase in the cardiac output secondary to arterial vasodilation. Volume changes as measured by the impedance method closely paralleled simultaneous changes in the ultrasonic crystal-determined segment length, and the impedance end-systolic pressure-volume relation slope was reproducible with repeated load-altering maneuvers.(ABSTRACT TRUNCATED AT 250 WORDS)


Asunto(s)
Cardiotónicos/farmacología , Dobutamina/farmacología , Epinefrina/farmacología , Contracción Miocárdica/efectos de los fármacos , Piridonas/farmacología , Quinazolinas/farmacología , Volumen Sistólico/efectos de los fármacos , Animales , Presión Sanguínea/efectos de los fármacos , Cardiografía de Impedancia , Constricción , Perros , Evaluación Preclínica de Medicamentos , Frecuencia Cardíaca/efectos de los fármacos , Milrinona , Porcinos , Vena Cava Inferior
12.
J Am Coll Cardiol ; 9(3): 655-60, 1987 Mar.
Artículo en Inglés | MEDLINE | ID: mdl-2950156

RESUMEN

Percutaneous balloon dilation of the aortic valve has recently been proposed as a palliative procedure for treating nonsurgical candidates with calcific aortic stenosis. To assess the safety, efficacy and mechanisms of successful balloon valvuloplasty, postmortem (n = 33) and intraoperative (n = 6) balloon aortic valvuloplasty was performed in the hearts of 39 elderly patients with calcific aortic stenosis. The cause of aortic stenosis was degenerative nodular calcification in 28 cases, calcific bicuspid aortic stenosis in 8 cases and rheumatic heart disease in 3 cases. Balloon dilation was performed with 15 to 25 mm balloons in the postmortem specimens, and with 18 to 20 mm balloons in the operating room immediately before aortic valve replacement. After balloon dilation, valve orifice dimensions and leaflet mobility increased in all patients. The mechanisms of successful dilation included fracture of calcified nodules in 16 aortic valves, separation of fused commissures in 5 valves, both in 6 valves and grossly inapparent microfractures in 12 valves. Valve leaflet avulsion occurred in one heart after inflation with a clearly oversized balloon. Liberation of calcific debris, valve ring disruption or midleaflet tears did not occur in any heart. In conclusion, there are at least three mechanisms of successful aortic valvuloplasty, depending on the origin of valvular stenosis. Embolic phenomena and acute valvular regurgitation do not appear to be likely events associated with this procedure.


Asunto(s)
Angioplastia de Balón , Estenosis de la Válvula Aórtica/cirugía , Calcinosis/cirugía , Válvulas Cardíacas/cirugía , Anciano , Angioplastia de Balón/efectos adversos , Fenómenos Biomecánicos , Válvulas Cardíacas/patología , Humanos , Periodo Intraoperatorio
13.
J Am Coll Cardiol ; 14(3): 677-82, 1989 Sep.
Artículo en Inglés | MEDLINE | ID: mdl-2768717

RESUMEN

Mitral regurgitation was serially assessed by pulsed Doppler echocardiography in 144 patients undergoing balloon aortic valvuloplasty for symptomatic aortic stenosis. Regurgitant scores of 0, 1, 2 and 3 were assigned to pulsed Doppler patterns corresponding to no, mild, moderate and severe mitral regurgitation, respectively. Before balloon aortic valvuloplasty, mitral regurgitant score correlated significantly (p less than 0.005) but weakly with aortic valve area (r = -0.24), left ventricular ejection fraction (r = -0.34) and left ventricular systolic pressure (r = 0.23). There was no significant correlation between mitral regurgitation and either mean catheterization or mean Doppler aortic valve gradient. Balloon aortic valvuloplasty produced significant decreases in both catheterization and Doppler mean transvalvular aortic valve gradients (56 +/- 19 to 31 +/- 12 and 60 +/- 19 to 48 +/- 16 mm Hg, respectively; both p less than 0.0001) and a significant increase (p less than 0.0001) in aortic valve area assessed by catheterization (0.6 +/- 0.2 to 0.9 +/- 0.3 cm2). Left ventricular ejection fraction did not change, but cardiac output increased (p less than 0.001) and pulmonary capillary wedge pressure decreased (p less than 0.0001). Pulsed Doppler findings of mitral regurgitation were present in 102 of the 144 patients. Eighty-eight patients had a score compatible with mild or more severe degrees of mitral regurgitation, and 49 had a score indicative of moderate or severe valvular insufficiency. In the entire group of 144 patients, mitral regurgitant score decreased significantly from 1.1 +/- 1.0 to 1.0 +/- 1.0 (p less than 0.001).(ABSTRACT TRUNCATED AT 250 WORDS)


Asunto(s)
Estenosis de la Válvula Aórtica/terapia , Cateterismo , Ecocardiografía Doppler , Insuficiencia de la Válvula Mitral/diagnóstico , Adulto , Anciano , Anciano de 80 o más Años , Femenino , Hemodinámica , Humanos , Masculino , Persona de Mediana Edad , Insuficiencia de la Válvula Mitral/fisiopatología
14.
J Am Coll Cardiol ; 18(7): 1779-86, 1991 Dec.
Artículo en Inglés | MEDLINE | ID: mdl-1960330

RESUMEN

Hemodynamic stress testing was performed in four calves with a chronically implanted left ventricular assist device consisting of a double-valved pump interposed between the left ventricular apex and the descending thoracic aorta. The device was powered either pneumatically (n = 1) or with a transcutaneous energy transmission system (n = 3). Hemodynamic evaluation (cardiac output and right and left ventricular and pulmonary and carotid artery pressures) was carried out at baseline and during all hemodynamically stressed states. Atrial pacing and ventricular pacing to a heart rate of 140 beats/min resulted in no significant change in right or left heart filling pressures or cardiac output. Preload reduction with nitroprusside or transient inferior vena cava balloon occlusion resulted in a marked decrease in left ventricular pressure with preservation of mean arterial pressure. Phenylephrine administration resulted in a marked rise in mean arterial pressure with no change in cardiac output or filling pressure. Induction of ventricular fibrillation resulted in a decrease of mean left ventricular pressure to 11 +/- 8 mm Hg, but mean arterial pressure was maintained at greater than or equal to 50 mm Hg. It is concluded that a multicomponent, implantable, electrically powered assist system is capable of maintaining a normal cardiac output under a wide range of loading conditions and chronotropic states. Although this device is clearly preload dependent, it is capable of maintaining normal systemic pressures during conditions of severe left ventricular dysfunction and circulatory collapse.


Asunto(s)
Electricidad , Cardiopatías/fisiopatología , Corazón Auxiliar/normas , Hemodinámica , Estrés Fisiológico/fisiopatología , Animales , Estimulación Cardíaca Artificial , Bovinos , Suministros de Energía Eléctrica , Electrocardiografía , Estudios de Evaluación como Asunto , Cardiopatías/diagnóstico , Cardiopatías/terapia , Nitroprusiato , Fenilefrina , Estrés Fisiológico/diagnóstico , Estrés Fisiológico/terapia , Fibrilación Ventricular/fisiopatología , Fibrilación Ventricular/terapia
15.
J Am Coll Cardiol ; 23(7): 1570-7, 1994 Jun.
Artículo en Inglés | MEDLINE | ID: mdl-8195516

RESUMEN

OBJECTIVES: This study was designed to assess the feasibility of using hydrogel-coated balloons to deliver biologically active agents to the blood vessel wall. BACKGROUND: The local intramural delivery of therapeutic agents during balloon angioplasty has been proposed as an adjunctive technique for preventing early intracoronary thrombosis and late restenosis. METHODS: To assess the efficacy of delivery and depth of penetration in vitro, local delivery of horseradish peroxidase was performed in 40 porcine peripheral arteries, and delivery of fluoresceinated heparin was performed in 20 porcine peripheral arteries and 7 human atheromatous arteries. To determine the persistence of these agents in the vessel wall in vivo, horseradish peroxidase was delivered to 18 porcine peripheral arteries that were harvested at intervals of 45 min to 48 h. Fluoresceinated heparin was delivered to 22 porcine peripheral arteries, 14 with the use of a protective sleeve, harvested at intervals of 30 s to 24 h. RESULTS: In vitro agent delivery was successful in all specimens. The depth of penetration of horseradish peroxidase was directly related to both balloon pressure (p < 0.04) and duration of inflation (p < 0.01). In vivo peroxidase staining was evident at 45 and 90 min but not thereafter. With the use of a protective sleeve, heparin was present in all arteries harvested at 30 s, with marked dissipation at 1 and 24 h. Without a sleeve, no fluorescein staining was detected in any artery. With both agents, delivery occurred consistently over broad regions of the vessel wall that were free of architectural disruption. CONCLUSIONS: Hydrogel-coated balloons can deliver biologically active agents to the vessel wall without gross tissue disruption and may provide an atraumatic method for the local delivery of therapeutic agents during balloon angioplasty.


Asunto(s)
Angioplastia de Balón/instrumentación , Sistemas de Liberación de Medicamentos , Polietilenglicoles , Animales , Difusión , Estudios de Factibilidad , Femenino , Heparina/administración & dosificación , Peroxidasa de Rábano Silvestre/administración & dosificación , Humanos , Hidrogel de Polietilenoglicol-Dimetacrilato , Técnicas In Vitro , Masculino , Presión , Porcinos
16.
J Am Coll Cardiol ; 3(6): 1469-81, 1984 Jun.
Artículo en Inglés | MEDLINE | ID: mdl-6715706

RESUMEN

To assess the relation between extent of ischemia and the magnitude of hemodynamic changes, 25 patients (5 with normal coronary arteries and 20 with significant coronary obstructive disease) were studied with rapid atrial pacing and thallium scintigraphy at the time of cardiac catheterization. Hemodynamic variables were measured before, during and after maximal pacing. Thallium was injected intravenously during maximal pacing and scans in three standard views were obtained immediately in the catheterization laboratory, with delayed scans obtained 4 hours after the cessation of pacing. The three thallium scans were each subdivided into five segments, and a thallium score was obtained on the basis of the total number of segments that were hypoperfused. Each patient was assigned a total thallium score corresponding to thallium defects at maximal pacing, as well as a redistributed thallium score corresponding to the difference between thallium score at maximal pacing and that 4 hours later. With pacing, patients with normal coronary arteries demonstrated no significant change in baseline hemodynamic variables, whereas patients with coronary artery disease exhibited a decrease in cardiac index, an increase in systemic vascular resistance, a widening of arteriovenous oxygen difference, an increase in pulmonary capillary wedge pressure and mean pulmonary artery pressure during maximal pacing and an increase in left ventricular end-diastolic pressure immediately after pacing. There was a significant correlation (Spearman rank r = 0.64, p less than 0.01) between redistributed thallium score and an increase in left ventricular end-diastolic pressure in the postpacing period. Moreover, there was an even higher correlation (Spearman rank r = 0.90, p less than 0.001) between total thallium score and the postpacing increase in end-diastolic pressure. It is concluded that in patients with coronary artery disease the magnitude of pacing-induced hemodynamic changes reflects both the amount of myocardial tissue at ischemic jeopardy and the total mass of hypoperfused myocardium during maximal pacing stress.


Asunto(s)
Prueba de Esfuerzo/métodos , Corazón/diagnóstico por imagen , Hemodinámica , Adulto , Anciano , Estimulación Cardíaca Artificial , Angiografía Coronaria , Femenino , Corazón/fisiopatología , Humanos , Masculino , Persona de Mediana Edad , Miocardio/patología , Radioisótopos , Cintigrafía , Talio
17.
J Am Coll Cardiol ; 3(2 Pt 1): 301-12, 1984 Feb.
Artículo en Inglés | MEDLINE | ID: mdl-6420453

RESUMEN

Assessment of left ventricular pressure-volume relations serially in response to altered loading conditions and heart rate has been difficult to achieve with contrast ventriculography. Accordingly, to study changing pressure-volume relations during altered loading and heart rate, left ventricular pressure and radionuclide absolute volume curves (obtained using a counts-based method with attenuation factor corrections) were recorded in 20 patients. Ventricular pressure and radionuclide volume curves were digitized and synchronized to end-diastole, and pressure-volume plots were subsequently constructed from 32 pressure-volume coordinates throughout the cardiac cycle. In all patients, the correlation between radionuclide absolute volumes and angiographic ventricular volumes was r = 0.92. In 10 patients in whom both radionuclide and angiographic pressure-volume diagrams were constructed, the agreement between the two methods was excellent. With this method, end-systolic pressure-volume relations were examined during altered left ventricular loading conditions, pacing-induced incremental increases in heart rate and pacing-induced ischemia. Using pharmacologically induced changes in left ventricular loading conditions, the slope and volume intercept of the end-systolic pressure-volume line could be calculated as a means of assessing basal contractility. During pacing-induced tachycardia, the slope and volume intercept of the end-systolic pressure-volume line could be calculated to quantify the Treppe effect and assess negative inotropic changes secondary to ischemia. This study supports the validity of using serial recordings of left ventricular pressure and radionuclide volumes to assess left ventricular pressure-volume relations, and indicates that this approach may be useful in the analysis of end-systolic pressure-volume relations in patients.


Asunto(s)
Corazón/fisiología , Contracción Miocárdica , Estimulación Cardíaca Artificial , Angiografía Coronaria , Ecocardiografía , Eritrocitos , Femenino , Corazón/diagnóstico por imagen , Corazón/fisiopatología , Cardiopatías/diagnóstico , Frecuencia Cardíaca , Humanos , Masculino , Persona de Mediana Edad , Nitroglicerina , Fenilefrina , Cintigrafía , Estrés Mecánico , Volumen Sistólico , Tecnecio
18.
J Am Coll Cardiol ; 3(5): 1197-204, 1984 May.
Artículo en Inglés | MEDLINE | ID: mdl-6707369

RESUMEN

Many patients suspected of having coronary artery disease are unable to undergo adequate exercise testing. An alternate stress, pacing tachycardia, has been shown to produce electrocardiographic changes that are as sensitive and specific as those observed during exercise testing. To compare thallium-201 imaging after atrial pacing stress with thallium imaging after exercise stress, 22 patients undergoing cardiac catheterization were studied with both standard exercise thallium imaging and pacing thallium imaging. Positive ischemic electrocardiographic changes (greater than 1 mm ST segment depression) were noted in 11 of 16 patients with coronary artery disease during exercise, and in 15 of the 16 patients during atrial pacing. One of six patients with normal or trivial coronary artery disease had a positive electrocardiogram with each test. Exercise thallium imaging was positive in 13 of 16 patients with coronary artery disease compared with 15 of 16 patients during atrial pacing. Three of six patients without coronary artery disease had a positive scan with exercise testing, and two of these same patients developed a positive scan with atrial pacing. Of those patients with coronary artery disease and an abnormal scan, 85% showed redistribution with exercise testing compared with 87% during atrial pacing. Segment by segment comparison of thallium imaging after either atrial pacing or exercise showed that there was a good correlation of the location and severity of the thallium defects (r = 0.83, p = 0.0001, Spearman rank correlation). It is concluded that the location and presence of both fixed and transient thallium defects after atrial pacing are closely correlated with the findings after exercise testing.(ABSTRACT TRUNCATED AT 250 WORDS)


Asunto(s)
Estimulación Cardíaca Artificial , Enfermedad Coronaria/diagnóstico por imagen , Prueba de Esfuerzo , Corazón/diagnóstico por imagen , Radioisótopos , Talio , Adulto , Anciano , Cineangiografía , Enfermedad Coronaria/fisiopatología , Electrocardiografía , Corazón/fisiopatología , Atrios Cardíacos/diagnóstico por imagen , Atrios Cardíacos/fisiopatología , Humanos , Persona de Mediana Edad , Cintigrafía , Taquicardia/diagnóstico por imagen , Taquicardia/fisiopatología
19.
J Am Coll Cardiol ; 32(7): 1996-2002, 1998 Dec.
Artículo en Inglés | MEDLINE | ID: mdl-9857884

RESUMEN

OBJECTIVES: The purpose of this study was to compare the outcome of primary percutaneous transluminal coronary angioplasty for acute myocardial infarction (MI) when performed with or without the platelet glycoprotein IIb/IIIa antibody, abciximab. BACKGROUND: Abciximab improves the outcome of angioplasty but the effect of abciximab in primary angioplasty has not been investigated. METHODS: Data were collected from a computerized database. Follow-up was by telephone or review of outpatient or hospital readmission records. RESULTS: A total of 182 consecutive patients were included; 103 received abciximab and 79 did not. The procedural success rate was 95% in the two groups. At 30-day follow-up, the composite event rate of unstable angina, reinfarction, target vessel revascularization and death from all causes was 13.5% in the group of patients who did not receive abciximab, 4% (p < 0.05) in the abciximab group and 2.4% (p < 0.05) in the subgroup of patients (n = 87) who completed the 12-h abciximab infusion. At the end of follow-up (mean 7+/-4 months), the composite event rate was 32.4%, 17% (p < 0.05) and 13.1% (p < 0.01) in these three categories respectively. Abciximab bolus followed by a 12-h infusion was an independent predictor of event-free survival, in a Cox proportional hazards model (relative risk 0.49; 95% confidence interval 0.24 to 0.99; p < 0.05). CONCLUSIONS: Abciximab given at the time of primary angioplasty may improve the short- and medium-term outcome of patients with acute MI, especially when a 12-h infusion is completed.


Asunto(s)
Angioplastia Coronaria con Balón , Anticuerpos Monoclonales/uso terapéutico , Fragmentos Fab de Inmunoglobulinas/uso terapéutico , Infarto del Miocardio/terapia , Inhibidores de Agregación Plaquetaria/uso terapéutico , Abciximab , Anciano , Femenino , Humanos , Masculino , Persona de Mediana Edad , Análisis Multivariante , Infarto del Miocardio/mortalidad , Modelos de Riesgos Proporcionales , Análisis de Supervivencia , Resultado del Tratamiento
20.
J Am Coll Cardiol ; 21(1): 189-98, 1993 Jan.
Artículo en Inglés | MEDLINE | ID: mdl-8417061

RESUMEN

OBJECTIVES: This study was designed to determine the clinical utility and feasibility of using 12.5-MHz ultrasound catheters for intracardiac echocardiography. BACKGROUND: Intracardiac echocardiography is a potentially useful technique of cardiac imaging and monitoring in certain settings. The feasibility of intracardiac echocardiography using 20-MHz ultrasound catheters in patients has been demonstrated. High resolution images of normal cardiac structures as well as cardiac abnormalities have been obtained. However, imaging has been limited by the shallow depth of field inherent in high frequency ultrasound imaging. METHODS: Intracardiac echocardiography with 12.5-MHz catheters was performed in eight mongrel dogs and 92 patients. Catheters were introduced percutaneously in 80 patients studied in the catheterization laboratory and directly into the heart in 12 patients in the operating room. Right heart imaging was performed in 68 patients and arterial and left heart imaging in 35 patients. RESULTS: When these catheters were introduced into the venous system, the right atrium, tricuspid valve, right ventricle, pulmonary valve and pulmonary artery were visualized. Pericardial effusion, intracardiac masses and atrial septal defects were correctly identified. The left ventricle, left atrium, mitral valve, aortic valve, aorta and coronary arteries could be imaged from the arterial circulation. Diseases identified included valvular aortic stenosis, subvalvular aortic stenosis and Kawasaki disease. Average imaging time was 10 min. No complications occurred as a result of intracardiac echocardiography. CONCLUSIONS: Intracardiac echocardiography with 12.5-MHz ultrasound catheters is safe and feasible; it also provides anatomic and physiologic information. This feasibility study provides a foundation for wider clinical use of intracardic echocardiography.


Asunto(s)
Cateterismo Cardíaco/instrumentación , Ecocardiografía/instrumentación , Adolescente , Adulto , Anciano , Animales , Artefactos , Cateterismo Cardíaco/métodos , Enfermedades Cardiovasculares/diagnóstico por imagen , Niño , Preescolar , Perros , Ecocardiografía/métodos , Diseño de Equipo , Estudios de Evaluación como Asunto , Humanos , Persona de Mediana Edad , Transductores