Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 23
Filtrar
1.
J Surg Orthop Adv ; 33(1): 37-40, 2024.
Artículo en Inglés | MEDLINE | ID: mdl-38815077

RESUMEN

This is a retrospective case series of patients with distal radius fractures treated with an indirect coronal reduction technique previously described by the senior author using volar locking plates. Seventeen distal radius fractures underwent treatment at a Level I Trauma Center and were retrospectively reviewed for anatomic alignment, surgical complications, and wrist range of motion in the global period. Near-anatomic restoration was achieved with the average radial inclination, radial height, and volar tilt measured as 23.2 ± 3.9 degrees, 11.8 ± 2.1 degrees, and 8.5 ± 5.4 degrees, respectively. Average coronal translation was 2.8 ± 2.7 mm. Postoperative wrist motion on average was within the normal ranges for pronation, supination, wrist flexion, and wrist extension at an average of 36 weeks follow-up. There were no complications related to surgical technique or implant. This case series demonstrates the reliability for coronal reduction with a volar locking plate technique without complications. (Journal of Surgical Orthopaedic Advances 33(1):037-040, 2024).


Asunto(s)
Placas Óseas , Fijación Interna de Fracturas , Fracturas del Radio , Rango del Movimiento Articular , Humanos , Fracturas del Radio/cirugía , Estudios Retrospectivos , Masculino , Femenino , Persona de Mediana Edad , Fijación Interna de Fracturas/métodos , Adulto , Anciano , Anciano de 80 o más Años , Fracturas de la Muñeca
2.
J Surg Orthop Adv ; 31(4): 233-236, 2022.
Artículo en Inglés | MEDLINE | ID: mdl-36594980

RESUMEN

This study's objective was to identify a difference in maximum temperature change during forward versus oscillating drilling of cadaveric bone. Paired femurs were dissected from the soft tissue of five cadavers. Each cadaver had one femur assigned to forward and the other to oscillation. The first drill hole was 2.5 cm distal to the lesser trochanter and the remaining 10 holes were evenly spaced 2 cm apart. A System 7 drill and 3.5 mm drill bit were attached to an Instron 5500R to provide a progressive force of 50 Newtons per minute for each drill hole. A thermal camera recorded each drilling. A new drill bit was used for each femur. Fifty bicortical drillings were analyzed in each group. The average time to complete forward drilling (45.0 seconds) was shorter compared to oscillation (55.5 s, p < 0.001). The average force required for forward drilling (27.7 N) was lower than for oscillation (44.3N, p < 0.001). The maximum change in temperature during the drilling process was similar (oscillating 100.2° F vs. forward 100.7° F, p = 0.871). The maximum change in temperature at the near cortex was lower for oscillation (78.1°F) compared to forward drilling (89.1°F, p = 0.011), while the maximum change at the far cortex was lower for forward drilling (89.3°F) compared to oscillation (95.8°F, p = 0.115) but not significantly. Overall, there is no difference in the thermal output between techniques. Oscillation may be beneficial in proximity to vital structures or to navigate narrow bony corridors, but it requires additional time and force. (Journal of Surgical Orthopaedic Advances 31(4):233-236, 2022).


Asunto(s)
Huesos , Procedimientos Ortopédicos , Humanos , Temperatura , Huesos/cirugía , Fémur/cirugía
3.
J Surg Orthop Adv ; 30(2): 78-81, 2021.
Artículo en Inglés | MEDLINE | ID: mdl-34181521

RESUMEN

The purpose of this study was to identify the ideal start site for a retrograde intramedullary fibular cortical screw based on its relationship to the surrounding soft tissue structures and to assess for damage to the surrounding soft tissue structures caused during placement of the screw. Four fresh frozen cadavers underwent fluoroscopic placement of a 3.5 mm cortical screw utilizing a standardized protocol. No damage to the peroneal tendons were noted in any cadaver with the foot in an inverted and plantarflexed position. The closest structure to the center of the screw head was the anterior talofibular ligament anteriorly (3.33 mm range: 3-4 mm) and the calcaneofibular ligament posteriorly (2.66 mm, range: 2-3 mm). Two screws violated the malleolar fossa medially and were noted to impinge on the lateral process of the talus. The ideal start site for a 3.5 mm intramedullary fibular screw is at the midline on the lateral radiograph and 3.0 mm lateral to the malleolar fossa on the AP radiograph. This avoids damage to the anterior talofibular ligament (ATFL) and calcaneofibular ligament (CFL) and prevents impingement on the lateral process of the talus. (Journal of Surgical Orthopaedic Advances 30(2):078-081, 2021).


Asunto(s)
Inestabilidad de la Articulación , Ligamentos Laterales del Tobillo , Astrágalo , Articulación del Tobillo/diagnóstico por imagen , Articulación del Tobillo/cirugía , Tornillos Óseos , Cadáver , Peroné/cirugía , Humanos , Astrágalo/diagnóstico por imagen , Astrágalo/cirugía
4.
J Surg Orthop Adv ; 29(4): 199-201, 2020.
Artículo en Inglés | MEDLINE | ID: mdl-33416475

RESUMEN

Vancouver B1 periprosthetic fractures undergoing operative fixation remain difficult to treat due to a short proximal segment that offers limited options for fixation. The trochanteric hook plate addresses this issue by maximizing proximal purchase and utilizing the entire lateral surface area of the greater trochanter. A surgical technique that prioritizes proximal fixation and adheres to basic principles resulted in all fractures healing in a small case series. (Journal of Surgical Orthopaedic Advances 29(4):199-201, 2020).


Asunto(s)
Artroplastia de Reemplazo de Cadera , Fracturas del Fémur , Fracturas Periprotésicas , Placas Óseas , Fracturas del Fémur/cirugía , Fémur , Fijación Interna de Fracturas , Humanos , Fracturas Periprotésicas/cirugía , Resultado del Tratamiento
5.
Trauma Case Rep ; 51: 101017, 2024 Jun.
Artículo en Inglés | MEDLINE | ID: mdl-38590921

RESUMEN

Background: Gluteal Compartment Syndrome (GCS) is a rare subtype of acute compartment syndrome (ACS), complex to diagnose and potentially fatal if left untreated. The incidence of ACS is estimated to be 7.3 per 100,000 in males and 0.7 per 100,000 in females [1-3]. Given its rare occurrence, the incidence of GCS is not well reported. In the case of GCS, the most common etiologies are surgical positioning, prolonged immobilization secondary to substance use or loss of consciousness, and traumatic injury. Clinical findings are pulselessness, pallor, parasthesia, paralysis, and most notably pain out of proportion. Swift diagnosis and treatment are imperative to reduce morbidity and mortality, however the ideal management of GCS is difficult to ascertain given the rare occurrence and variable presentation. Methods: Orthopaedic trauma database at a level 1 trauma center was reviewed to identify patients for whom the orthopaedic service was consulted due to suspicion of gluteal compartment syndrome. This yielded 11 patients between 2011 and 2019. Patients with a measured ΔP greater than 30 upon initial consultation and with a concerning exam requiring monitoring were included. Patient demographics, comorbidities, GCS etiology, laboratory values, physical exam findings, pain scores (0-10) and patient outcomes were collected via chart review. Patient demographic and injury characteristics were summarized using descriptive statistics. Results: Prolonged immobilization patients had worse outcomes including longer hospital stays (40.5 days) compared to trauma patients (4.5 days). All adverse medical outcomes recorded including acute renal failure, prolonged neuropathic pain, cardiopulmonary dysfunction were exclusively experienced by prolonged immobilization patients. Conclusions: Our descriptive study demonstrates the bimodal distribution of GCS patients based on etiology. Prolonged immobilization patients have a longer hospital course and more complications. Our study confirms prior reports and provides information that can be used to counsel patients and families appropriately about treatment and recovery following GCS. Level of evidence: IV. Study type: Epidemiological.

6.
J Orthop Trauma ; 38(3): 129-133, 2024 Mar 01.
Artículo en Inglés | MEDLINE | ID: mdl-38117571

RESUMEN

OBJECTIVES: Evaluate the effect of anterior fixation on infection in patients with operative pelvic fractures and bladder or urethral injuries. DESIGN: Retrospective. SETTING: Eight centers. PATIENT SELECTION CRITERIA: Adult patients with closed pelvic fractures with associated bladder or urethral injuries treated with anterior plating (AP), intramedullary screw (IS), or no anterior internal fixation (NAIF, including external fixation or no fixation). OUTCOME MEASURES AND COMPARISONS: Deep infection. RESULTS: There were 81 extraperitoneal injuries and 57 urethral injuries. There was no difference in infection between fixation groups across all urologic injuries (AP: 10.8%, IS: 0%, NAIF: 4.9%, P = 0.41). There was a higher rate of infection in the urethral injury group compared with extraperitoneal injuries (14.0% vs. 2.5%, P = 0.016). Among extraperitoneal injuries, specifically, there was no difference in deep infection related to fixation (AP: 2.6%, IS 0%, NAIF: 2.9%, P = 0.99). Among urethral injuries, there was no statistical difference in deep infection related to fixation (AP: 23.1%, IS: 0%, NAIF: 7.4%, P = 0.21). There was a higher rate of suprapubic catheter (SPC) use in urethral injuries compared with extraperitoneal injuries (57.9% vs. 4.9%, P < 0.0001). In the urethral injury group, SPC use did not have a statistically significant difference in infection rate (SPC: 18.2% vs. No SPC: 8.3%, P = 0.45). Early removal of the SPC before or during the definitive orthopaedic intervention did not significantly affect infection rate (early: 0% vs. delayed: 25.0%, P = 0.16). CONCLUSIONS: Surgeons should approach operative pelvic fractures with associated urologic injuries with caution given the high risk of infection. Further work must be done to elucidate the effect of anterior implants and SPC use and duration. LEVEL OF EVIDENCE: Prognostic Level III. See Instructions for Authors for a complete description of levels of evidence.


Asunto(s)
Fracturas Óseas , Infecciones , Huesos Pélvicos , Adulto , Humanos , Vejiga Urinaria/lesiones , Estudios Retrospectivos , Fracturas Óseas/cirugía , Fracturas Óseas/complicaciones , Fijación Interna de Fracturas/efectos adversos , Huesos Pélvicos/cirugía , Huesos Pélvicos/lesiones , Infecciones/complicaciones
7.
J Orthop Trauma ; 38(3): 143-147, 2024 Mar 01.
Artículo en Inglés | MEDLINE | ID: mdl-38117575

RESUMEN

OBJECTIVES: To evaluate the work relative value units (RVUs) attributed per minute of operative time (wRVU/min) in fixation of acetabular fractures, evaluate surgical factors that influence wRVU/min, and compare wRVU/min with other procedures. DESIGN: Retrospective. SETTING: Level 1 academic center. PATIENT SELECTION CRITERIA: Two hundred fifty-one operative acetabular fractures (62 A, B, C) from 2015 to 2021. OUTCOME MEASURES AND COMPARISONS: Work relative value unit per minute of operative time for each acetabular current procedural terminology (CPT) code. Surgical approach, patient positioning, total room time, and surgeon experience were collected. Comparison wRVU/min were collected from the literature. RESULTS: The mean wRVU per surgical minute for each CPT code was (1) CPT 27226 (isolated wall fracture): 0.091 wRVU/min, (2) CPT 27227 (isolated column or transverse fracture): 0.120 wRVU/min, and (3) CPT 27228 (associated fracture types): 0.120 wRVU/min. Of fractures with single approaches, anterior approaches generated the least wRVU/min (0.091 wRVU/min, P = 0.0001). Average nonsurgical room time was 82.1 minutes. Surgeon experience ranged from 3 to 26 years with operative time decreasing as surgeon experience increased ( P = 0.03). As a comparison, the wRVU/min for primary and revision hip arthroplasty have been reported as 0.26 and 0.249 wRVU/min, respectively. CONCLUSIONS: The wRVUs allocated per minute of operative time for acetabular fractures is less than half of other reported hip procedures and lowest for isolated wall fractures. There was a significant amount of nonsurgical room time that should be accounted for in compensation models. This information should be used to ensure that orthopaedic trauma surgeons are being appropriately supported for managing these fractures. LEVEL OF EVIDENCE: Economic Level IV. See Instructions for Authors for a complete description of levels of evidence.


Asunto(s)
Fracturas de Cadera , Ortopedia , Fracturas de la Columna Vertebral , Cirujanos , Humanos , Tempo Operativo , Estudios Retrospectivos
8.
J Orthop Trauma ; 36(6): e255-e259, 2022 06 01.
Artículo en Inglés | MEDLINE | ID: mdl-35703848

RESUMEN

SUMMARY: Antibiotic-coated implants are increasing in prevalence in the treatment of fracture-related infections. Coated plates may be desirable in certain anatomic locations or to augment nail fixation. We describe a simple, reproducible technique for the fabrication of antibiotic-coated plates and our initial results of a small case series.


Asunto(s)
Fijación Intramedular de Fracturas , Fracturas Óseas , Antibacterianos/uso terapéutico , Clavos Ortopédicos , Placas Óseas , Desbridamiento , Fijación Interna de Fracturas/métodos , Fijación Intramedular de Fracturas/métodos , Fracturas Óseas/complicaciones , Fracturas Óseas/cirugía , Humanos , Resultado del Tratamiento
9.
J Orthop Trauma ; 35(Suppl 5): S16-S20, 2021 Oct 01.
Artículo en Inglés | MEDLINE | ID: mdl-34533497

RESUMEN

SUMMARY: Distal radius fractures are common in the geriatric population; however, treatment of these fractures remains controversial. Patients undergoing operative fixation may experience a quicker recovery with increased grip strength, which is beneficial in the active geriatric patient. Treatment options include fragment-specific fixation, volar locked plating, and dorsal bridge plating. External fixation alone leads to poor outcomes and is indicated in patients with soft tissue compromise or as a supplemental aid. Implant selection should be tailored to fracture parameters. With a thoughtful surgical algorithm and rehabilitation protocol, good outcomes can be achieved with a high rate of patient satisfaction.


Asunto(s)
Fracturas del Radio , Anciano , Placas Óseas , Fijación de Fractura , Fijación Interna de Fracturas , Humanos , Satisfacción del Paciente , Fracturas del Radio/cirugía , Rango del Movimiento Articular
10.
J Orthop Trauma ; 35(Suppl 2): S48-S49, 2021 08 01.
Artículo en Inglés | MEDLINE | ID: mdl-34227610

RESUMEN

SUMMARY: This video reviews the technique of a vascularized fibula flap for pediatric tibia reconstruction. A 4-year-old boy with a history of a left tibial infected nonunion status after multiple debridements presented with segmental bone loss and difficulty with ambulation. An ipsilateral vascularized fibula flap was used for reconstruction. The patient proceeded to union and was independently ambulatory with bracing.


Asunto(s)
Neoplasias Óseas , Procedimientos de Cirugía Plástica , Neoplasias Óseas/cirugía , Trasplante Óseo , Niño , Preescolar , Peroné/cirugía , Humanos , Masculino , Tibia/cirugía
11.
J Orthop Trauma ; 35(4): e148-e152, 2021 04 01.
Artículo en Inglés | MEDLINE | ID: mdl-32569069

RESUMEN

SUMMARY: Treatment of periprosthetic distal femur fractures remains challenging due to assuring adequate distal fixation. Traditional treatment options include lateral locked plating and retrograde nailing, although recently dual implant constructs have been explored with promising results. Allowing immediate weight-bearing in this patient population has benefits with regards to rehabilitation and outcome. Recent literature has focused on nail-plate constructs, however plate-plate constructs are preferred at our institution as they do not require arthroplasty component compatibility, facilitate the coronal plane reduction, and allow for immediate weight-bearing.


Asunto(s)
Artroplastia de Reemplazo de Rodilla , Fracturas del Fémur , Fracturas Periprotésicas , Placas Óseas , Fracturas del Fémur/diagnóstico por imagen , Fracturas del Fémur/cirugía , Fémur , Fijación Interna de Fracturas , Humanos , Fracturas Periprotésicas/diagnóstico por imagen , Fracturas Periprotésicas/cirugía
12.
JBJS Case Connect ; 10(2): e0149, 2020.
Artículo en Inglés | MEDLINE | ID: mdl-32649087

RESUMEN

CASE: An open obturator dislocation with associated pelvic ring injury and perineal wound underwent fixation and aggressive debridement. Despite this, the patient proceeded to infection requiring additional debridements and prolonged intravenous antibiotics. At 18 months postinjury, the patient developed avascular necrosis and significant heterotopic ossification; however, she was able to ambulate. CONCLUSIONS: Open obturator dislocations of the hip require a multidisciplinary team. Despite prompt antibiotic therapy and aggressive debridement, patients are at high risk of infection because of the microbial environment in this region. Open obturator hip dislocations are at significant risk of avascular necrosis despite timely reduction.


Asunto(s)
Fijación Intramedular de Fracturas , Fracturas Conminutas/cirugía , Luxación de la Cadera/cirugía , Huesos Pélvicos/lesiones , Perineo/lesiones , Accidentes de Tránsito , Adolescente , Femenino , Necrosis de la Cabeza Femoral/etiología , Fracturas Conminutas/complicaciones , Fracturas Conminutas/diagnóstico por imagen , Luxación de la Cadera/complicaciones , Luxación de la Cadera/diagnóstico por imagen , Humanos , Osteomielitis/etiología , Reoperación
13.
J Orthop ; 18: 99-103, 2020.
Artículo en Inglés | MEDLINE | ID: mdl-32021012

RESUMEN

This study investigated differences between patients <65 and ≥65 years of age following lumbar microdecompression. Differences between age groups were investigated with univariate analyses. A linear mixed effects model was fit to the study outcomes. 144 patients were studied. There was no difference in two-year outcomes between the age groups. Outcome measures showed improvement compared to baseline at one- and two-years (p < 0.001). Age group had a significant effect on back pain (p = 0.016). Patients ≥65 years of age may experience greater relief in back pain following microdecompression. Nonetheless, significant improvement is observed in both age groups at two-years.

14.
J Orthop Trauma ; 34(6): 302-306, 2020 Jun.
Artículo en Inglés | MEDLINE | ID: mdl-32433194

RESUMEN

OBJECTIVES: To compare the efficiency, radiation exposure to surgeon and patient, and accuracy of C-arm versus O-arm with navigation in the placement of transiliac-transsacral and iliosacral screws by an orthopaedic trauma fellow, for a surgeon early in practice. METHODS: Twelve fresh frozen cadavers were obtained. Preoperative computed tomography scans were reviewed to assess for safe corridors in the S1 and S2 segments. Iliosacral screws were assigned to the S1 segment in dysmorphic pelvises. Screws were randomized to modality and laterality. An orthopaedic trauma fellow placed all screws. Time of procedure and radiation exposure to the cadaver and surgeon were recorded. Three fellowship-trained orthopaedic trauma surgeons rated the safety of each screw on postoperative computed tomography scan. RESULTS: Six normal and 6 dysmorphic pelvises were identified. Eighteen transiliac-transsacral screws and 6 iliosacral screws were distributed evenly between C-arm and O-arm. Average operative duration per screw was significantly shorter using C-arm compared with O-arm (15.7 minutes ± 6.1 vs. 23.7 ± 8.5, P = 0.014). Screw placement with C-arm exposed the surgeon to a significantly greater amount of radiation (3.87 × 10 rads vs. 0.32 × 10, P < 0.001) while O-arm exposed the cadaver to a significantly greater amount of radiation (0.03 vs. 2.76 rads, P < 0.001). Two S2 transiliac-transsacral screws (1 C-arm and 1 O-arm) were categorized as unsafe based on scoring. There was no difference in screw accuracy between modalities. CONCLUSIONS: A difference in accuracy between modalities could not be elucidated, whereas efficiency was improved with utilization of C-arm, with statistical significance. A statistically significant increase in radiation exposure to the surgeon using C-arm was found, which may be clinically significant over a career. The results of this study can be extrapolated to a fellow or surgeon early in practice. The decision between use of these modalities will vary depending on surgeon preference and hospital resources.


Asunto(s)
Exposición a la Radiación , Cirujanos , Cirugía Asistida por Computador , Tornillos Óseos , Cadáver , Humanos , Imagenología Tridimensional , Exposición a la Radiación/prevención & control , Sacro/diagnóstico por imagen , Sacro/cirugía , Tomografía Computarizada por Rayos X
15.
J Orthop Trauma ; 33 Suppl 6: S29-S32, 2019 Sep.
Artículo en Inglés | MEDLINE | ID: mdl-31404043

RESUMEN

Treatment of periprosthetic fractures above total knee arthroplasty remains challenging because of assessment of implant stability and the short segment of often osteoporotic bone available for distal fixation. Fractures with significant medial comminution should undergo retrograde intramedullary nailing or dual-implant fixation, as isolated lateral locked plating is not indicated. There are a multitude of objective and subjective factors incorporated into the decision to proceed with retrograde nailing including assessment of the patient's functional status, fracture morphology, implant stability, and compatibility of the prosthesis with retrograde nailing. Here, we review the steps to success in using retrograde intramedullary nailing in the treatment of specific periprosthetic fractures about total knee arthroplasty.


Asunto(s)
Artroplastia de Reemplazo de Rodilla/efectos adversos , Placas Óseas , Fracturas del Fémur/cirugía , Fijación Intramedular de Fracturas/métodos , Fracturas Periprotésicas/cirugía , Fracturas del Fémur/diagnóstico , Curación de Fractura , Humanos , Fracturas Periprotésicas/diagnóstico , Radiografía , Reoperación , Resultado del Tratamiento
16.
J Orthop Trauma ; 33 Suppl 1: S1-S6, 2019 Jan.
Artículo en Inglés | MEDLINE | ID: mdl-30540665

RESUMEN

Femoral neck fractures in the physiologically young patient are challenging injuries to manage. A tenuous blood supply and the intrasynovial nature of the fracture create a challenging biological environment. To make matters worse, the biomechanics are equally problematic. Frequently, these fractures in younger populations are high Pauwel angle fractures that see considerable force, especially shear. These factors combine to make nonunion and avascular necrosis all too common. In the current study, we will highlight the challenges inherent to managing these injuries and will discuss techniques and implants that may help mitigate some of these challenges.


Asunto(s)
Fracturas del Cuello Femoral/cirugía , Fijación Interna de Fracturas/métodos , Fracturas no Consolidadas/cirugía , Fracturas del Cuello Femoral/diagnóstico , Fracturas no Consolidadas/diagnóstico , Humanos , Radiografía , Reoperación
17.
J Orthop Trauma ; 33 Suppl 1: S32-S33, 2019 Aug.
Artículo en Inglés | MEDLINE | ID: mdl-31290830

RESUMEN

Long-bone deformity may be significantly symptomatic. A uniplanar corrective osteotomy uses a single cut to correct coronal, sagittal, and axial plane deformity simultaneously. Careful preoperative planning is required in addition to a comprehensive understanding of the magnitude and plane of the true deformity of the bone. With precise operative technique and intraoperative assessment of correction, good results can be achieved.


Asunto(s)
Desviación Ósea/cirugía , Fémur/cirugía , Fracturas Mal Unidas/cirugía , Osteotomía/métodos , Desviación Ósea/diagnóstico , Desviación Ósea/etiología , Fémur/diagnóstico por imagen , Fracturas Mal Unidas/complicaciones , Fracturas Mal Unidas/diagnóstico , Humanos , Tomografía Computarizada por Rayos X
18.
J Orthop Trauma ; 33(7): 341-345, 2019 Jul.
Artículo en Inglés | MEDLINE | ID: mdl-30730363

RESUMEN

OBJECTIVES: To report on our results using a proximal femoral locking plate for the treatment of peritrochanteric femur fractures. DESIGN: Retrospective study. SETTING: Level I Academic Medical Center. PATIENTS: Sixty-eight patients with 68 fractures. INTERVENTION: Demographics, fracture morphology, preoperative imaging, rationale against nailing, and outcomes were collected. MAIN OUTCOME MEASUREMENTS: Outcomes were grouped into no complication, minor complication, or major complication. Minor complications included healed fractures with implant failure or change in alignment from immediate postoperative radiographs, which did not require intervention or elective implant removal. Major complications included any case that required revision for nonunion or implant failure. RESULTS: Nine patients were lost to follow-up. Of the 59 fractures, 16 had complications (27%): 9 minor and 7 major. Active tobacco use (P = 0.020) and fractures with an associated intracapsular femoral neck component (P = 0.006) correlated with complications. CONCLUSIONS: Proximal femoral locking plates continue to be associated with a high complication rate. However, based on our experience, proximal femoral locking plates may be considered in highly selected cases when absolutely no other implant is deemed appropriate, based on the degree of comminution and the complexity of the fracture pattern. Patients must be informed about the possibility of revision surgery based on the inherent limitations of these devices. LEVEL OF EVIDENCE: Therapeutic Level IV. See Instructions for Authors for a complete description of levels of evidence.


Asunto(s)
Placas Óseas , Fracturas del Fémur/cirugía , Fijación Interna de Fracturas/métodos , Curación de Fractura , Tornillos Óseos , Fracturas del Fémur/diagnóstico , Estudios de Seguimiento , Humanos , Radiografía , Estudios Retrospectivos
19.
J Orthop Trauma ; 33 Suppl 1: S26-S27, 2019 Aug.
Artículo en Inglés | MEDLINE | ID: mdl-31290827

RESUMEN

Valgus intertrochanteric osteotomy is an effective method of treating femoral neck nonunion by reducing shear forces at the fracture and correcting the neck-shaft angle. Good outcomes have been reported in the literature. Through careful preoperative planning and a precise operative technique, reliable healing of both the osteotomy and nonunion can be achieved.


Asunto(s)
Fracturas del Cuello Femoral/cirugía , Cuello Femoral/cirugía , Fijación Interna de Fracturas/métodos , Curación de Fractura , Fracturas no Consolidadas/cirugía , Osteotomía/métodos , Humanos
20.
World Neurosurg ; 131: e290-e297, 2019 Nov.
Artículo en Inglés | MEDLINE | ID: mdl-31356984

RESUMEN

OBJECTIVE: To assess factors that may predict failure to improve at 12 and 24 months after unilateral laminotomy with bilateral decompression (ULBD) for the management of lumbar spinal stenosis. METHODS: A database of 255 patients who underwent microdecompression surgery by a single orthopedic spine surgeon between 2014 and 2018 was queried. Patients who underwent primary single-level ULBD of the lumbar spine were included. Visual analog scale (VAS) for back pain and leg pain and Oswestry Disability Index (ODI) results were collected preoperatively and at 12 and 24 months postoperatively. Demographic, radiographic, and operative factors were assessed for associations with failure to improve. Clinically important improvement was defined as reaching or surpassing the previously established minimum clinically important difference for ODI (12.8) and not requiring revision. RESULTS: A total of 68 patients were included. Compared with preoperative values for back pain, leg pain, and ODI (7.32, 7.53, and 51.22, respectively), there were significant improvements on follow-up at 12 months (2.89, 2.23, and 22.40, respectively; P < 0.001) and 24 months (2.80, 2.11, 20.32, respectively; P < 0.001). Based on the defined criteria, 50 patients showed clinically important improvement after ULBD. Of the 18 patients who failed to improve, 12 required revision. Independent predictors of failure to improve included female sex (adjusted odds ratio, 5.06; 95% confidence interval, 1.49-21.12; P = 0.014) and current smoker status (adjusted odds ratio, 5.39; 95% confidence interval, 1.39-23.97; P = 0.018). CONCLUSIONS: ULBD for the management of lumbar spinal stenosis leads to clinically important improvement that is maintained over a 24-month follow-up period. Female sex and tobacco smoking are associated with poorer outcomes.


Asunto(s)
Descompresión Quirúrgica , Laminectomía , Vértebras Lumbares/cirugía , Radiculopatía/cirugía , Estenosis Espinal/cirugía , Anciano , Femenino , Humanos , Pierna , Dolor de la Región Lumbar/etiología , Masculino , Persona de Mediana Edad , Diferencia Mínima Clínicamente Importante , Oportunidad Relativa , Dolor , Dimensión del Dolor , Radiculopatía/etiología , Radiculopatía/fisiopatología , Reoperación , Factores Sexuales , Estenosis Espinal/complicaciones , Estenosis Espinal/fisiopatología , Fumar Tabaco/epidemiología , Insuficiencia del Tratamiento
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA