Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 82
Filtrar
Más filtros

Bases de datos
País/Región como asunto
Tipo del documento
País de afiliación
Intervalo de año de publicación
1.
J Appl Clin Med Phys ; 22(11): 185-195, 2021 Nov.
Artículo en Inglés | MEDLINE | ID: mdl-34697869

RESUMEN

PURPOSE: Research productivity metrics are important for decisions regarding hiring, retention, and promotion in academic medicine, and these metrics can vary widely among different disciplines. This article examines productivity metrics for radiation therapy physicists (RTP) in the United States. METHODS AND MATERIALS: Database searches were performed for RTP faculty at US institutions that have RTP residencies accredited by the Commission on Accreditation of Medical Physics Education Programs (CAMPEP). Demographics, academic rank, number of publications, academic career length, Hirsch index (h-index), m-quotient, and history of National Institutes of Health (NIH) funding as a principal investigator (PI) were collected for each RTP. Logistic regression was performed to determine the probability of academic rank as a function of h-index and m-quotient. Statistical tests used included the Wilcoxon ranked sum test and the Pearson χ2 test. RESULTS: A total of 1038 faculty and staff were identified at 78 institutions with CAMPEP-accredited residencies. The average RTP academic career duration is 13.5 years, with 46.7 total publications, h-index of 10.7, and m-quotient of 0.66. Additionally, 10.5% of RTP have a history of NIH funding as a PI. Large disparities were found in academic productivity of doctoral-prepared physicists compared to those with a terminal master's degree. For differences in junior and senior faculty, statistical tests yielded significance in career duration, number of publications, h-index, and m-quotient. Gender disparities were identified in the overall distribution of RTP consistent with the membership of the American Association of Physicists in Medicine. Further gender disparities were found in the number of doctoral-prepared RTP and physicists in senior faculty roles. CONCLUSIONS: This manuscript provides objective benchmark data regarding research productivity of academic RTP. These data may be of interest to faculty preparing for promotion, and also to institutional leadership.


Asunto(s)
Investigación Biomédica , Internado y Residencia , Eficiencia , Docentes , Humanos , National Institutes of Health (U.S.) , Física , Estados Unidos
2.
J Appl Clin Med Phys ; 22(5): 89-96, 2021 May.
Artículo en Inglés | MEDLINE | ID: mdl-33783960

RESUMEN

PURPOSE: The purpose of this study was to evaluate the performance of three common deformable image registration (DIR) packages across algorithms and institutions. METHODS AND MATERIALS: The Deformable Image Registration Evaluation Project (DIREP) provides ten virtual phantoms derived from computed tomography (CT) datasets of head-and-neck cancer patients over a single treatment course. Using the DIREP phantoms, DIR results from 35 institutions were submitted using either Velocity, MIM, or Eclipse. Submitted deformation vector fields (DVFs) were compared to ground-truth DVFs to calculate target registration error (TRE) for six regions of interest (ROIs). Statistical analysis was performed to determine the variability between each DIR software package and the variability of users within each algorithm. RESULTS: Overall mean TRE was 2.04 ± 0.35 mm for Velocity, 1.10 ± 0.29 mm for MIM, and 2.35 ± 0.15 mm for Eclipse. The MIM mean TRE was significantly different than both Velocity and Eclipse for all ROIs. Velocity and Eclipse mean TREs were not significantly different except for when evaluating the registration of the cord or mandible. Significant differences between institutions were found for the MIM and Velocity platforms. However, these differences could be explained by variations in Velocity DIR parameters and MIM software versions. CONCLUSIONS: Average TRE was shown to be <3 mm for all three software platforms. However, maximum errors could be larger than 2 cm indicating that care should be exercised when using DIR. While MIM performed statistically better than the other packages, all evaluated algorithms had an average TRE better than the largest voxel dimension. For the phantoms studied here, significant differences between algorithm users were minimal suggesting that the algorithm used may have more impact on DIR accuracy than the particular registration technique employed. A significant difference in TRE was discovered between MIM versions showing that DIR QA should be performed after software upgrades as recommended by TG-132.


Asunto(s)
Algoritmos , Procesamiento de Imagen Asistido por Computador , Cabeza , Humanos , Fantasmas de Imagen , Tomografía Computarizada por Rayos X
3.
J Appl Clin Med Phys ; 21(12): 178-187, 2020 Dec.
Artículo en Inglés | MEDLINE | ID: mdl-33226709

RESUMEN

PURPOSE: Real-time magnetic resonance guided radiation therapy (MRgRT) uses 2D cine imaging for target tracking. This work evaluates the percent image uniformity (PIU) and spatial integrity of cine images in the presence of multileaf collimator (MLC) and gantry motion in order to simulate sliding window and volumetric modulated arc therapy (VMAT) conditions. METHODS: Percent image uniformity and spatial integrity of cine images were measured (1) during MLC motion, (2) as a function of static gantry position, and (3) during gantry rotation. PIU was calculated according to the ACR MRI Quality Control Manual. Spatial integrity was evaluated by measuring the geometric distortion of 16 measured marker positions (10 cm or 15.225 cm from isocenter). RESULTS: The PIU of cine images did not vary by more than 1% from static linac conditions during MLC motion and did not vary by more than 3% during gantry rotation. Banding artifacts were present during gantry rotation. The geometric distortion in the cine images was less than 0.88 mm for all points measured throughout MLC motion. For all static gantry positions, the geometric distortion was less than 0.88 mm at 10 cm from isocenter and less than 1.4 mm at 15.225 cm from isocenter. During gantry rotation, the geometric distortion remained less than 0.92 mm at 10 cm from isocenter and less than 1.60 mm at 15.225 cm from isocenter. CONCLUSION: During MLC motion, cine images maintained adequate PIU, and the geometric distortion of points within 15.225 cm from isocenter was less than the 1 mm threshold necessary for real-time target tracking and gating. During gantry rotation, PIU was negatively affected by banding artifacts, and spatial integrity was only maintained within 10 cm from isocenter. Future work should investigate the effects imaging artifacts have on real-time target tracking during MRgRT.


Asunto(s)
Aceleradores de Partículas , Radioterapia de Intensidad Modulada , Humanos , Imagen por Resonancia Magnética , Espectroscopía de Resonancia Magnética , Control de Calidad
4.
J Appl Clin Med Phys ; 19(3): 149-158, 2018 May.
Artículo en Inglés | MEDLINE | ID: mdl-29682879

RESUMEN

PURPOSE: To describe the commissioning of AIRO mobile CT system (AIRO) for adaptive proton therapy on a compact double scattering proton therapy system. METHODS: A Gammex phantom was scanned with varying plug patterns, table heights, and mAs on a CT simulator (CT Sim) and on the AIRO. AIRO-specific CT-stopping power ratio (SPR) curves were created with a commonly used stoichiometric method using the Gammex phantom. A RANDO anthropomorphic thorax, pelvis, and head phantom, and a CIRS thorax and head phantom were scanned on the CT Sim and AIRO. Clinically realistic treatment plans and nonclinical plans were generated on the CT Sim images and subsequently copied onto the AIRO CT scans for dose recalculation and comparison for various AIRO SPR curves. Gamma analysis was used to evaluate dosimetric deviation between both plans. RESULTS: AIRO CT values skewed toward solid water when plugs were scanned surrounded by other plugs in phantom. Low-density materials demonstrated largest differences. Dose calculated on AIRO CT scans with stoichiometric-based SPR curves produced over-ranged proton beams when large volumes of low-density material were in the path of the beam. To create equivalent dose distributions on both data sets, the AIRO SPR curve's low-density data points were iteratively adjusted to yield better proton beam range agreement based on isodose lines. Comparison of the stoichiometric-based AIRO SPR curve and the "dose-adjusted" SPR curve showed slight improvement on gamma analysis between the treatment plan and the AIRO plan for single-field plans at the 1%, 1 mm level, but did not affect clinical plans indicating that HU number differences between the CT Sim and AIRO did not affect dose calculations for robust clinical beam arrangements. CONCLUSION: Based on this study, we believe the AIRO can be used offline for adaptive proton therapy on a compact double scattering proton therapy system.


Asunto(s)
Algoritmos , Cabeza/diagnóstico por imagen , Fantasmas de Imagen , Terapia de Protones , Planificación de la Radioterapia Asistida por Computador/métodos , Tomografía Computarizada por Rayos X/instrumentación , Humanos , Procesamiento de Imagen Asistido por Computador/métodos , Órganos en Riesgo/efectos de la radiación , Dosificación Radioterapéutica , Radioterapia de Intensidad Modulada/métodos , Tomografía Computarizada por Rayos X/métodos
5.
J Appl Clin Med Phys ; 18(3): 130-136, 2017 May.
Artículo en Inglés | MEDLINE | ID: mdl-28436155

RESUMEN

PURPOSE: The purpose of this study was to characterize the Mobius AIRO Mobile CT System for localization and image-guided proton therapy. This is the first known application of the AIRO for proton therapy. METHODS: Five CT images of a Catphan® 504 phantom were acquired on the AIRO Mobile CT System, Varian EDGE radiosurgery system cone beam CT (CBCT), Philips Brilliance Big Bore 16 slice CT simulator, and Siemens SOMATOM Definition AS 20 slice CT simulator. DoseLAB software v.6.6 was utilized for image quality analysis. Modulation transfer function, scaling discrepancy, geometric distortion, spatial resolution, overall uniformity, minimum uniformity, contrast, high CNR, and maximum HU deviation were acquired. Low CNR was acquired manually using the CTP515 module. Localization accuracy and CT Dose Index were measured and compared to reported values on each imaging device. For treatment delivery systems (Edge and Mevion), the localization accuracy of the 3D imaging systems were compared to 2D imaging systems on each system. RESULTS: The AIRO spatial resolution was 0.21 lp mm-1 compared with 0.40 lp mm-1 for the Philips CT Simulator, 0.37 lp mm-1 for the Edge CBCT, and 0.35 lp mm-1 for the Siemens CT Simulator. AIRO/Siemens and AIRO/Philips differences exceeded 100% for scaling discrepancy (191.2% and 145.8%). The AIRO exhibited higher dose (>27 mGy) than the Philips CT Simulator. Localization accuracy (based on the MIMI phantom) was 0.6° and 0.5 mm. Localization accuracy (based on Stereophan) demonstrated maximum AIRO-kV/kV shift differences of 0.1 mm in the x-direction, 0.1 mm in the y-direction, and 0.2 mm in the z-direction. CONCLUSIONS: The localization accuracy of AIRO was determined to be within 0.6° and 0.5 mm despite its slightly lower image quality overall compared to other CT imaging systems at our institution. Based on our study, the Mobile AIRO CT system can be utilized accurately and reliably for image-guided proton therapy.


Asunto(s)
Terapia de Protones/instrumentación , Radiocirugia/instrumentación , Radioterapia Guiada por Imagen/instrumentación , Tomografía Computarizada por Rayos X , Tomografía Computarizada de Haz Cónico , Diseño de Equipo , Humanos , Fantasmas de Imagen , Terapia de Protones/métodos , Radiocirugia/métodos , Radioterapia Guiada por Imagen/métodos
6.
J Appl Clin Med Phys ; 17(3): 25-40, 2016 05 08.
Artículo en Inglés | MEDLINE | ID: mdl-27167256

RESUMEN

Benchmarking is a process in which standardized tests are used to assess system performance. The data produced in the process are important for comparative purposes, particularly when considering the implementation and quality assurance of DIR algorithms. In this work, five commercial DIR algorithms (MIM, Velocity, RayStation, Pinnacle, and Eclipse) were benchmarked using a set of 10 virtual phantoms. The phantoms were previously developed based on CT data collected from real head and neck patients. Each phantom includes a start of treatment CT dataset, an end of treatment CT dataset, and the ground-truth deformation vector field (DVF) which links them together. These virtual phantoms were imported into the commercial systems and registered through a deformable process. The resulting DVFs were compared to the ground-truth DVF to determine the target registration error (TRE) at every voxel within the image set. Real treatment plans were also recalculated on each end of treatment CT dataset and the dose transferred according to both the ground-truth and test DVFs. Dosimetric changes were assessed, and TRE was correlated with changes in the DVH of individual structures. In the first part of the study, results show mean TRE on the order of 0.5 mm to 3 mm for all phan-toms and ROIs. In certain instances, however, misregistrations were encountered which produced mean and max errors up to 6.8 mm and 22 mm, respectively. In the second part of the study, dosimetric error was found to be strongly correlated with TRE in the brainstem, but weakly correlated with TRE in the spinal cord. Several interesting cases were assessed which highlight the interplay between the direction and magnitude of TRE and the dose distribution, including the slope of dosimetric gradients and the distance to critical structures. This information can be used to help clinicians better implement and test their algorithms, and also understand the strengths and weaknesses of a dose adaptive approach.


Asunto(s)
Algoritmos , Neoplasias de Cabeza y Cuello/patología , Procesamiento de Imagen Asistido por Computador/métodos , Fantasmas de Imagen , Benchmarking , Femenino , Humanos , Masculino , Interpretación de Imagen Radiográfica Asistida por Computador , Tomografía Computarizada por Rayos X
7.
J Appl Clin Med Phys ; 14(3): 4210, 2013 May 06.
Artículo en Inglés | MEDLINE | ID: mdl-23652252

RESUMEN

Intrafraction motion during intensity-modulated radiation therapy can cause differences between the planned and delivered patient dose. The magnitude of these differences is dependent on a number of variables, including the treatment modality. This study was designed to compare the relative susceptibility of plans generated with three different treatment modalities to intrafraction motion. The dosimetric effects of motion were calculated using computational algorithms for seven lung tumor patients. Three delivery techniques - MLC-based step-and-shoot (SNS), beam attenuating compensators, and helical tomotherapy (HT) - were investigated. In total 840 motion-encoded dose-volume histograms (DVHs) were calculated for various combinations of CTV margins and sinusoidal CTV motion including CTV offsets. DVH-based metrics (e.g., D95% and D05%) were used to score plan degradations. For all three modalities, dosimetric degradations were typically smaller than 3% if the CTV displacement was smaller than the CTV margin. For larger displacements, technique and direction-specific sensitivities existed. While the HT plans show similar D95% degradations for motion in the SI and AP directions, SNS and compensator plans showed larger D95% degradations for motion in the SI direction than for motion in the AP direction. When averaged over all motion/margin combinations, compensator plans resulted in 0.9% and 0.6% smaller D95% reductions compared to SNS and HT plans, respectively. These differences were statistically significant. No statistically significant differences in D95% degradations were found between SNS and HT for data averaged over all margin and motion track combinations. For CTV motion that is larger than the CTV margin, the dosimetric impact on the CTV varies with treatment technique and the motion direction. For the cases presented here, the effect of motion on CTV dosimetry was statistically smaller for compensator deliveries than SNS and HT, likely due to the absence of the interplay effect which is present for the more dynamic treatment deliveries. The differences between modalities were, however, small and might not be clinically significant. As expected, margins that envelop the CTV motion provide dosimetric protection against motion for all three modalities.


Asunto(s)
Neoplasias Pulmonares/radioterapia , Movimiento , Planificación de la Radioterapia Asistida por Computador , Radioterapia de Intensidad Modulada , Algoritmos , Fraccionamiento de la Dosis de Radiación , Humanos , Estudios Retrospectivos
8.
Pract Radiat Oncol ; 13(1): e3-e6, 2023.
Artículo en Inglés | MEDLINE | ID: mdl-35944807

RESUMEN

 : Magnetic resonance image guided adaptive radiation therapy (MRgART) represents a significant improvement in our ability to deliver therapeutic radiation. However, for the process of MRgART to be carried out safely and efficiently, the covering radiation oncologist must be aware of all aspects of a patient's case, because they will be required to recontour and replan the patient before each treatment. In this report, we will demonstrate our initial experience with a video sign-out process to convey the detailed level of information required for the covering physician to treat patients safely and effectively with MRgART. We then describe our optimized video sign-out process to allow for other centers to adopt a similar approach.


Asunto(s)
Planificación de la Radioterapia Asistida por Computador , Radioterapia Guiada por Imagen , Humanos , Flujo de Trabajo , Dosificación Radioterapéutica , Planificación de la Radioterapia Asistida por Computador/métodos , Imagen por Resonancia Magnética/métodos , Radioterapia Guiada por Imagen/métodos
9.
Int J Part Ther ; 10(2): 85-93, 2023.
Artículo en Inglés | MEDLINE | ID: mdl-38075486

RESUMEN

Purpose: Many patients with metastatic cancer live years beyond diagnosis, and there remains a need to improve the therapeutic ratio of metastasis-directed radiation for these patients. This study aimed to assess a process for delivering cost-effective palliative proton therapy to the spine using diagnostic scan-based planning (DSBP) and prefabricated treatment delivery devices. Materials and Methods: We designed and characterized a reusable proton aperture system that adjusts to multiple lengths for spine treatment. Next, we retrospectively identified 10 patients scan treated with thoracic proton therapy who also had a diagnostic computed tomography within 4 months of simulation. We contoured a T6-T9 target volume on both the diagnostic scans (DS) and simulation scans (SS). Using the aperture system, we generated proton plans on the DS using a posterior-anterior beam with no custom range compensator to treat T6-T9 to 8 Gy × 1. Plans were transferred to the SS to compare coverage and normal tissue doses, followed by robustness analysis. Finally, we compared normal tissue doses and costs between proton and photon plans. Results were compared using the Wilcoxon signed-rank test. Results: Median D95% on the DS plans was 101% (range, 100%-102%) of the prescription dose. Median Dmax was 107% (range, 105%-108%). When transferred to SS, coverage and hot spots remained acceptable for all cases. Heart and esophagus doses did not vary between the DS and SS proton plans (P >.2). Robustness analysis with 5 mm X/Y/Z shifts showed acceptable coverage (D95% > 98%) for all cases. Compared with the proton plans, the mean heart dose was higher for both anterior-posterior/posterior-anterior and volumetric modulated arc therapy plans (P < .01). Cost for proton DSBP was comparable to more commonly used photon regimens. Conclusion: Proton DSBP is technically feasible and robust, with superior sparing of the heart compared with photons. Eliminating simulation and custom devices increases the value of this approach in carefully selected patients.

10.
Int J Part Ther ; 9(1): 54-63, 2022.
Artículo en Inglés | MEDLINE | ID: mdl-35774494

RESUMEN

Purpose: To present quantitative dosimetric evaluations of five proton pencil beam spot placement techniques. Materials and Methods: The spot placement techniques that were investigated include two grid-based (rectilinear grid and hexagonal grid, both commonly available in commercial planning systems) and three boundary-contoured (concentric contours, hybrid, and optimized) techniques. Treatment plans were created for two different target volumes, one spherical and one conical. An optimal set of planning parameters was defined for all treatment plans and the impact of spot placement techniques on the plan quality was evaluated in terms of lateral/distal dose falloff, normal tissue sparing, conformity and homogeneity of dose distributions, as well as total number of spots used. Results: The results of this work highlight that for grid-based spot placement techniques, the dose conformity is dependent on target cross-sectional shape perpendicular to beam direction, which changes for each energy layer. This variable conformity problem is mitigated by using boundary contoured spot placement techniques. However, in the case of concentric contours, the conformity is improved but at the cost of decreased homogeneity inside the target. Hybrid and optimized spot placement techniques, which use contoured spots at the boundary and gridlike interior spot patterns, provide more uniform dose distributions inside the target volume while maintaining the improved dose conformity. The optimized spot placement technique improved target coverage, homogeneity of dose, and minimal number of spots. The dependence of these results on spot size is also presented for both target shapes. Conclusion: This work illustrates that boundary-contoured spot placement techniques offer marked improvement in dosimetry metrics when compared to commercially available grid-based techniques for a range of proton scanned beam spot sizes.

11.
J Clin Med ; 11(5)2022 Feb 23.
Artículo en Inglés | MEDLINE | ID: mdl-35268279

RESUMEN

With the implementation of MR-LINACs, real-time adaptive radiotherapy has become a possibility within the clinic. However, the process of adapting a patient's plan is time consuming and often requires input from the entire clinical team, which translates to decreased throughput and limited patient access. In this study, the authors propose and simulate a workflow to address these inefficiencies in staffing and patient throughput. Two physicians, three radiation therapists (RTT), and a research fellow each adapted bladder and bowel contours for 20 fractions from 10 representative patient plans. Contouring ability was compared via calculation of a Dice Similarity Index (DSI). The DSI for bladder and bowel based on each potential physician-therapist pair, as well as an inter-physician comparison, exhibited good overlap amongst all comparisons (p = 0.868). Plan quality was compared through calculation of the conformity index (CI), as well as an evaluation of the plan's dose to a 'gold standard' set of structures. Overall, non-physician plans passed 91.2% of the time. Of the eight non-physician plans that failed their clinical evaluation, six also failed their evaluation against the 'gold standard'. Another two plans that passed their clinical evaluation subsequently failed in their evaluation against the 'gold standard'. Thus, the PF-ROAR process has a success rate of 97.5%, with 78/80 plans correctly adapted to the gold standard or halted at treatment. These findings suggest that a physician-free workflow can be well tolerated provided RTTs continue to develop knowledge of MR anatomy and careful attention is given to understanding the complexity of the plan prior to treatment.

12.
Int J Part Ther ; 9(2): 10-19, 2022.
Artículo en Inglés | MEDLINE | ID: mdl-36060418

RESUMEN

Purpose: We present an analysis of various operational metrics for a novel compact proton therapy system, including clinical case mix, subsystems utilization, and quality assurance trends in beam delivery parameters over a period of 5 years. Materials and Methods: Patient-specific data from a total of 850 patients (25,567 fractions) have been collected and analyzed. The patient mix include a variety of simple, intermediate, and complex cases. Beam-specific delivery parameters for a total of 3585 beams were analyzed. In-room imaging system usage for off-line adaptive purpose is reported. We also report key machine performances metrics based on routine quality assurance in addition to uptime. Results: Our analysis shows that system subcomponents including gantry and patient positioning system have maintained a tight mechanical tolerance over the 5-year period. Various beam parameters were all within acceptable tolerances with no clear trends. Utilization frequency histograms of gantry and patient positioning system show that only a small fraction of all available angles was used for patient deliveries with cardinal angels as the most usable. Similarly, beam-specific metrics, such as range, modulation, and air gaps, were clustered unevenly over the available range indicating that this compact system was more than capable to treat the complex variety of tumors of our patient mix. Conclusion: Our data show that this compact system is versatile, robust, and capable of delivering complex treatments like a large full-gantry system. Utilization data show that a fraction of all subcomponents range of angular motion has been used. Compilation of beam-specific metrics, such as range and modulation, show uneven distributions with specific clustering over the entire usable range. Our findings could be used to further optimize the performance and cost-effectiveness of future compact proton systems.

13.
Pract Radiat Oncol ; 12(3): 195-199, 2022.
Artículo en Inglés | MEDLINE | ID: mdl-34619373

RESUMEN

The purpose of this paper is to summarize treatment guidelines for the performance of single isocenter LINAC radiosurgery of multiple brain metastases developed and used by 3 experienced centers. This article is not meant to provide consensus guidelines. Rather, this is a practical, "how we do it" reference without substantial discussion. To serve as a treatment reference, the great majority of the information is presented in topic-specific tables.


Asunto(s)
Neoplasias Encefálicas , Radiocirugia , Neoplasias Encefálicas/radioterapia , Neoplasias Encefálicas/secundario , Neoplasias Encefálicas/cirugía , Humanos , Dosificación Radioterapéutica , Planificación de la Radioterapia Asistida por Computador
14.
Med Phys ; 38(8): 4505-11, 2011 Aug.
Artículo en Inglés | MEDLINE | ID: mdl-21928620

RESUMEN

PURPOSE: A number of techniques are available to determine the dosimetric impact of intrafraction motion during intensity modulated radiation therapy (IMRT). Motion-induced dose perturbations can be determined both computationally and experimentally using a number of different dosimetric metrics. However, these measures may lead to different conclusions regarding the clinical impact of motion. This study compares the analysis of identical dose perturbations using different dosimetric metrics. Calculated changes in target D95% are used as a reference. METHODS: A total of 3768 motion-encoded dose distributions were calculated for nine lung tumor patients. The motion-encoded dose distributions were compared to static dose distributions using three dosimetric metrics: 2D gamma, 3D gamma, and histogram analysis. Each of these metrics was used to analyze dose perturbations both globally and within the target structure. Furthermore, the failing voxels were analyzed separately according to failure mode, i.e., under vs. over-dosed voxels. Metrics were evaluated based on their agreement with changes in target D95%. Evaluations included the metrics' maximum average sensitivity and specificity (MASS) in detecting unacceptable deliveries, a coefficient correlated to ranking (tau), and the linear correlation coefficient, r. RESULTS: Of the evaluated metrics, the histogram metric restricted to the under-dosed voxels within the target agreed best with changes in target D95%. This metric achieved a MASS of 0.93, a tau of 0.69, and an r-value of 0.85. In comparison, the unrestricted 2D gamma metric achieved MASS = 0.77, tau = 0.40, and r = 0.67. Restricting the 2D gamma test both geographically and in failure mode increased the MASS to 0.85, tau to 0.70, and the r-value to 0.80. CONCLUSIONS: This study suggests that any clinical decisions based solely on an unrestricted 2D gamma metric are suboptimal. A geographic and failure mode restriction can improve results. The remaining uncertainties with non-DVH (dose volume histogram) based metrics should be kept in mind when they are used to evaluate the dosimetric impact of target motion.


Asunto(s)
Radioterapia de Intensidad Modulada/estadística & datos numéricos , Humanos , Neoplasias Pulmonares/radioterapia , Movimiento (Física) , Movimiento , Dosificación Radioterapéutica , Planificación de la Radioterapia Asistida por Computador/estadística & datos numéricos
15.
J Appl Clin Med Phys ; 12(4): 3590, 2011 Nov 15.
Artículo en Inglés | MEDLINE | ID: mdl-22089017

RESUMEN

In the past 10 years, techniques to improve radiotherapy delivery, such as intensity-modulated radiation therapy (IMRT), image-guided radiation therapy (IGRT) for both inter- and intrafraction tumor localization, and hypofractionated delivery techniques such as stereotactic body radiation therapy (SBRT), have evolved tremendously. This review article focuses on only one part of that evolution, electromagnetic tracking in radiation therapy. Electromagnetic tracking is still a growing technology in radiation oncology and, as such, the clinical applications are limited, the expense is high, and the reimbursement is insufficient to cover these costs. At the same time, current experience with electromagnetic tracking applied to various clinical tumor sites indicates that the potential benefits of electromagnetic tracking could be significant for patients receiving radiation therapy. Daily use of these tracking systems is minimally invasive and delivers no additional ionizing radiation to the patient, and these systems can provide explicit tumor motion data. Although there are a number of technical and fiscal issues that need to be addressed, electromagnetic tracking systems are expected to play a continued role in improving the precision of radiation delivery.


Asunto(s)
Neoplasias/radioterapia , Radioterapia de Intensidad Modulada/métodos , Fenómenos Electromagnéticos , Humanos
16.
Stud Health Technol Inform ; 163: 567-73, 2011.
Artículo en Inglés | MEDLINE | ID: mdl-21335858

RESUMEN

This paper reports on the usage of physics-based 3D volumetric lung dynamic models for visualizing and monitoring the radiation dose deposited on the lung of a human subject during lung radiotherapy. The dynamic model of each subject is computed from a 4D Computed Tomography (4DCT) imaging acquired before the treatment. The 3D lung deformation and the radiation dose deposited are computed using Graphics Processing Units (GPU). Additionally, using the dynamic lung model, the airflow inside the lungs during the treatment is also investigated. Results show the radiation dose deposited on the lung tumor as well as the surrounding tissues, the combination of which is patient-specific and varies from one treatment fraction to another.


Asunto(s)
Imagenología Tridimensional/métodos , Neoplasias Pulmonares/diagnóstico por imagen , Neoplasias Pulmonares/radioterapia , Radioterapia Asistida por Computador/métodos , Técnicas de Imagen Sincronizada Respiratorias/métodos , Tomografía Computarizada por Rayos X/métodos , Interfaz Usuario-Computador , Sistemas de Computación , Humanos , Tamaño de los Órganos , Radioterapia Conformacional/métodos
17.
JCO Oncol Pract ; 17(12): e1949-e1957, 2021 12.
Artículo en Inglés | MEDLINE | ID: mdl-34460290

RESUMEN

PURPOSE: An episode-based payment model, the Radiation Oncology Alternative Payment Model (RO-APM), is scheduled to go into effect in January 2022. This article investigates the effects of RO-APM on hospital-based and freestanding community centers. METHODS: Historical Medicare data used to generate the RO-APM base rates were reviewed. A sensitivity analysis was performed to show how the RO-APM reimbursements compare with current reimbursements for commonly accepted treatment schedules and with current reimbursements at a large community practice. RESULTS: The RO-APM base rates represent a 2.2% decrease in overall Medicare reimbursement. Freestanding centers have historically billed at higher rates than hospital-based centers, however, and the RO-APM base rates represent a 6% decrease in global reimbursement for freestanding centers. The sensitivity analysis showed that, except for proton therapy, moderately hypofractionated treatment schedules will receive comparable reimbursement under RO-APM. Treatments using higher numbers of fractions of intensity-modulated radiation therapy or protons will see larger decreases in reimbursement. Application of the RO-APM base rates to the 2020 Medicare treatments in our health care network would result in small changes in expected reimbursement, but our sensitivity analysis indicated that Medicare reimbursement reductions could be as large as 23%. CONCLUSION: Compared with historical Medicare reimbursement, RO-APM base rates provide lower reimbursement for many common treatment scenarios, and this will have a larger effect on centers that use complex treatment techniques and longer fractionation schedules or have a large Medicare population.


Asunto(s)
Neoplasias , Oncología por Radiación , Anciano , Atención a la Salud , Humanos , Oncología Médica , Medicare , Neoplasias/radioterapia , Estados Unidos
18.
Med Dosim ; 46(3): 264-268, 2021.
Artículo en Inglés | MEDLINE | ID: mdl-33771435

RESUMEN

The purpose of this work was to evaluate using Varian HyperArc as a planning and treatment solution for whole brain radiotherapy (WBRT) with hippocampal sparing following Radiation Therapy Oncology Group (RTOG) 0933 dosimetric criteria. Ten patients previously treated for intracranial lesions were retrospectively planned for WBRT with hippocampal sparing using HyperArc and a 2-arc coplanar VMAT technique. The whole brain and hippocampus were delineated on fused MRI and CT datasets. The planning target volume (PTV), defined as the whole brain excluding the hippocampal avoidance region, was prescribed 30 Gy in 10 fractions. Plans were evaluated using dosimetric parameters which included the volume of 105% of the prescription dose (V105%) and the maximum dose to the PTV, and the minimum dose to the hippocampus. The planning time, delivery time, and delivery quality assurance (QA) results were also evaluated. Statistical significance was performed between the HyperArc and coplanar VMAT metrics using the Wilcoxon signed-rank test with a significance level of 0.05. All plans met RTOG 0933 dosimetric criteria. HyperArc plans demonstrated significant improvements in PTV dosimetric quality which included a reduced V105% of 6 ± 7% and decreased maximum dose of 1.3 ± 0.3 Gy, compared to coplanar VMAT. Significant OAR sparing was also found for HyperArc plans that included a decreased minimum dose to the hippocampus of 0.3 ± 0.3 Gy. Coplanar VMAT plans resulted in significantly shorter planning and delivery times, compared to HyperArc, by 2.4 minutes and 1.5 minutes, respectively. No significant difference was found between the delivery QA results. This study demonstrated using Varian HyperArc as a planning and treatment solution for WBRT with hippocampal sparing following RTOG 0933 dosimetric criteria. The primary advantages of WBRT with hippocampal sparing using HyperArc, compared to coplanar VMAT, are the gains in OAR sparing and reduced high dose volumes to the PTV.


Asunto(s)
Neoplasias Encefálicas , Radioterapia de Intensidad Modulada , Encéfalo , Neoplasias Encefálicas/radioterapia , Hipocampo , Humanos , Órganos en Riesgo , Dosificación Radioterapéutica , Planificación de la Radioterapia Asistida por Computador , Estudios Retrospectivos
19.
JCO Oncol Pract ; 17(12): e1943-e1948, 2021 12.
Artículo en Inglés | MEDLINE | ID: mdl-33170747

RESUMEN

PURPOSE: An episode-based payment model, the Radiation Oncology Alternative Payment Model (RO-APM), has been proposed for Medicare reimbursement of radiation services provided to oncology patients. RO-APM may have significant impact on reimbursement for specific patient populations. METHODS: This investigation compares historical fee-for-service technical reimbursement estimates at a large hospital-based system to the RO-APM for advanced radiotherapy treatment of specific cancer types. These advanced techniques, stereotactic radiosurgery (SRS), stereotactic body radiotherapy (SBRT), online-adaptive SBRT, and proton therapy, were specifically chosen because they are resource intensive and are correspondingly among the most expensive radiation oncology procedures. A total of 203 Medicare patients were analyzed. RESULTS: RO-APM base-rate reimbursements were similar for SRS and were 38%-47% higher for SBRT. The proposed rates were 1%-31% lower for online-adaptive SBRT, and 48%-71% lower for proton therapy. CONCLUSION: These data suggest that the RO-APM may have the desired effect of encouraging shorter courses of radiotherapy, such as SBRT. However, emerging technologies that require large capital and operating investments may see an overall significant reduction in proposed reimbursement.


Asunto(s)
Neoplasias , Terapia de Protones , Oncología por Radiación , Radiocirugia , Anciano , Humanos , Medicare , Neoplasias/radioterapia , Estados Unidos
20.
J Appl Clin Med Phys ; 12(1): 3311, 2010 Oct 07.
Artículo en Inglés | MEDLINE | ID: mdl-21330977

RESUMEN

We report on our initial experience with daily image guidance for the treatment of a patient with a basal cell carcinoma of the nasal dorsum using bolus electron conformal therapy. We describe our approach to daily alignment using treatment machine-integrated megavoltage (MV) planar imaging in conjunction with cone beam CT (CBCT) volumetric imaging to ensure the best possible setup reproducibility. Based on MV imaging, beam aperture misalignment with the intended treatment region was as large as 0.5 cm in the coronal plane. Four of the five fractions analyzed show induced shifts when compared to digitally reconstructed radiographs (DRR), in the range of 0.2-0.5 cm. Daily inspection of CBCT images show that the bolus device can have significant tilt in any given direction by as much as 13° with respect to beam axis. In addition, we show that CBCT images reveal air gaps between bolus and skin that vary from day to day, and can potentially degrade surface dose coverage. Retrospective dose calculation on CBCT image sets shows that when daily shifts based on MV imaging are not corrected, geometrical miss of the planning target volume (PTV) can cause an underdosing as large as 14% based on DVH analysis of the dose to the 90% of the PTV volume.


Asunto(s)
Tomografía Computarizada de Haz Cónico/métodos , Neoplasias Nasales/radioterapia , Interpretación de Imagen Radiográfica Asistida por Computador/métodos , Planificación de la Radioterapia Asistida por Computador/métodos , Radioterapia Conformacional/métodos , Algoritmos , Electrones/uso terapéutico , Humanos , Dosificación Radioterapéutica
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA