Med Eng Phys ; 107: 103854, 2022 09.
Artículo en Inglés | MEDLINE | ID: mdl-36068039

RESUMEN

We present a systematic and automated stepwise method to calibrate computational models of the spine. For that purpose, a sequential resection study on one lumbar specimen (L2-L5) was performed to obtain the individual contribution of the IVD, the facet joints and the ligaments to the kinematics of the spine. The experimental data was prepared for the calibration procedure in such manner that the FE model could reproduce the average motion of the 10 native spines from former cadaveric studies as well as replicate the proportional change in ROM after removal of a spinal structure obtained in this resection study. A Genetic Algorithm was developed to calibrate the properties of the intervertebral discs and facet joints. The calibration of each ligament was performed by a simple and novel technique that requires only one simulation to obtain its mechanical property. After calibration, the model was capable of reproducing the experimental results in all loading directions and resections.


Asunto(s)
Disco Intervertebral , Vértebras Lumbares , Fenómenos Biomecánicos , Calibración , Análisis de Elementos Finitos , Humanos , Vértebras Lumbares/cirugía , Rango del Movimiento Articular
2.
Braz Oral Res ; 282014.
Artículo en Inglés | MEDLINE | ID: mdl-24918366

RESUMEN

The purpose of this study was to evaluate the influence of buccal and lingual wall thickness on the fatigue resistance of molars restored with CAD/CAM ceramic inlays. Forty human third molars were selected and divided into 4 groups, according to the remaining surrounding wall thickness chosen for inlay preparation (n=10): G1, 2.0 mm; G2, 1.5 mm; G3, 1.0 mm; G4, 0.5 mm. All inlays were made from feldspathic ceramic blocks by a CAD/CAM system, and cemented adhesively. After 1 week stored in distilled water at 37 °C, the specimens were subjected to fatigue testing under the following protocol: 5Hz; pre-load of 200 N for 5,000 cycles, followed by increasing loads of 400, 600, 800, 1000, 1200 and 1400 N for 30,000 cycles each. The specimens were cycled until failure or completion of 185,000 cycles. The survival rate of the groups was compared using the Kaplan-Meier survival curves (p>0.05). All specimens withstood the fatigue protocol (185,000 cycles), representing a 100% survival rate. The Kaplan-Meier survival curves showed no difference between groups. It can be concluded that the remaining tooth wall thickness did not influence the fatigue resistance of molars restored with CAD/CAM ceramic inlays.


Asunto(s)
Cerámica/química , Incrustaciones/métodos , Diente Molar/anatomía & histología , Diseño Asistido por Computadora , Cementos Dentales/química , Fracaso de la Restauración Dental , Análisis del Estrés Dental , Humanos , Estimación de Kaplan-Meier , Ensayo de Materiales , Valores de Referencia , Reproducibilidad de los Resultados , Propiedades de Superficie , Factores de Tiempo