1.
Magn Reson Med ; 90(2): 552-568, 2023 08.
Artículo en Inglés | MEDLINE | ID: mdl-37036033

RESUMEN

PURPOSE: To develop 2D turbo spin-echo (TSE) imaging using annular spiral rings (abbreviated "SPRING-RIO TSE") with compensation of concomitant gradient fields and B0 inhomogeneity at both 0.55T and 1.5T for fast T2 -weighted imaging. METHODS: Strategies of gradient waveform modifications were implemented in SPRING-RIO TSE for compensation of self-squared concomitant gradient terms at the TE and across echo spacings, along with reconstruction-based corrections to simultaneously compensate for the residual concomitant gradient and B0 field induced phase accruals along the readout. The signal pathway disturbance caused by time-varying and spatially dependent concomitant fields was simulated, and echo-to-echo phase variations before and after sequence-based compensation were compared. Images from SPRING-RIO TSE with no compensation, with compensation, and Cartesian TSE were also compared via phantom and in vivo acquisitions. RESULTS: Simulation showed how concomitant fields affected the signal evolution with no compensation, and both simulation and phantom studies demonstrated the performance of the proposed sequence modifications, as well as the readout off-resonance corrections. Volunteer data showed that after full correction, the SPRING-RIO TSE sequence achieved high image quality with improved SNR efficiency (15%-20% increase), and reduced RF SAR (˜50% reduction), compared to the standard Cartesian TSE, presenting potential benefits, especially in regaining SNR at low-field (0.55T). CONCLUSION: Implementation of SPRING-RIO TSE with concomitant field compensation was tested at 0.55T and 1.5T. The compensation principles can be extended to correct for other trajectory types that are time-varying along the echo train and temporally asymmetric in TSE-based imaging.


Asunto(s)
Encéfalo , Imagen por Resonancia Magnética , Humanos , Imagen por Resonancia Magnética/métodos , Encéfalo/diagnóstico por imagen , Aumento de la Imagen/métodos , Fantasmas de Imagen , Fenómenos Magnéticos
2.
Magn Reson Med ; 89(6): 2255-2263, 2023 06.
Artículo en Inglés | MEDLINE | ID: mdl-36669874

RESUMEN

PURPOSE: To develop and test compressed sensing-based multiframe 3D MRI of grid-tagged hyperpolarized gas in the lung. THEORY AND METHODS: Applying grid-tagging RF pulses to inhaled hyperpolarized gas results in images in which signal intensity is predictably and sparsely distributed. In the present work, this phenomenon was used to produce a sampling pattern in which k-space is undersampled by a factor of approximately seven, yet regions of high k-space energy remain densely sampled. Three healthy subjects received multiframe 3D 3 He tagging MRI using this undersampling method. Images were collected during a single exhalation at eight timepoints spanning the breathing cycle from end-of-inhalation to end-of-exhalation. Grid-tagged images were used to generate 3D displacement maps of the lung during exhalation, and time-resolved maps of principal strains and fractional volume change were generated from these displacement maps using finite-element analysis. RESULTS: Tags remained clearly resolvable for 4-6 timepoints (5-8 s) in each subject. Displacement maps revealed noteworthy temporal and spatial nonlinearities in lung motion during exhalation. Compressive normal strains occurred along all three principal directions but were primarily oriented in the head-foot direction. Fractional volume changes displayed clear bilateral symmetry, but with the lower lobes displaying slightly higher change than the upper lobes in 2 of the 3 subjects. CONCLUSION: We developed a compressed sensing-based method for multiframe 3D MRI of grid-tagged hyperpolarized gas in the lung during exhalation. This method successfully overcomes previous challenges for 3D dynamic grid-tagging, allowing time-resolved biomechanical readouts of lung function to be generated.


Asunto(s)
Compresión de Datos , Pulmón , Masculino , Humanos , Pulmón/diagnóstico por imagen , Respiración , Imagen por Resonancia Magnética/métodos
3.
Vasc Med ; 28(4): 282-289, 2023 08.
Artículo en Inglés | MEDLINE | ID: mdl-37093712

RESUMEN

BACKGROUND: The distal superficial femoral artery (SFA) is most commonly affected in peripheral artery disease (PAD). The effects of the proprotein convertase subtilisin/kexin type 9 (PCSK9) inhibitor alirocumab added to statin therapy on SFA atherosclerosis, downstream flow, and walking performance are unknown. METHODS: Thirty-five patients with PAD on maximally tolerated statin therapy were recruited. Patients were randomized to alirocumab 150 mg subcutaneously (n = 18) or matching placebo (n = 17) therapy every 2 weeks for 1 year. The primary outcome was change in SFA plaque volume by black blood magnetic resonance imaging (MRI). Secondary outcomes were changes in calf muscle perfusion by cuff/occlusion hyperemia arterial spin labeling MRI, 6-minute walk distance (6MWD), low-density lipoprotein (LDL) cholesterol, and other biomarkers. RESULTS: Age (mean ± SD) was 64 ± 8 years, 20 (57%) patients were women, 17 (49%) were Black individuals, LDL was 107 ± 36 mg/dL, and the ankle-brachial index 0.71 ± 0.20. The LDL fell more with alirocumab than placebo (mean [95% CI]) (-49.8 [-66.1 to -33.6] vs -7.7 [-19.7 to 4.3] mg/dL; p < 0.0001). Changes in SFA plaque volume and calf perfusion showed no difference between groups when adjusted for baseline (+0.25 [-0.29 to 0.79] vs -0.04 [-0.47 to 0.38] cm3; p = 0.37 and 0.22 [-8.67 to 9.11] vs 3.81 [-1.45 to 9.08] mL/min/100 g; p = 0.46, respectively), nor did 6MWD. CONCLUSION: In this exploratory study, the addition of alirocumab therapy to statins did not alter SFA plaque volume, calf perfusion or 6MWD despite significant LDL lowering. Larger studies with longer follow up that include plaque characterization may improve understanding of the effects of intensive LDL-lowering therapy in PAD (ClinicalTrials.gov Identifier: NCT02959047).


Asunto(s)
Inhibidores de Hidroximetilglutaril-CoA Reductasas , Enfermedad Arterial Periférica , Placa Aterosclerótica , Humanos , Femenino , Persona de Mediana Edad , Anciano , Masculino , Proproteína Convertasa 9/uso terapéutico , Inhibidores de Hidroximetilglutaril-CoA Reductasas/efectos adversos , Anticuerpos Monoclonales/efectos adversos , LDL-Colesterol/uso terapéutico , Placa Aterosclerótica/inducido químicamente , Placa Aterosclerótica/tratamiento farmacológico , Enfermedad Arterial Periférica/diagnóstico por imagen , Enfermedad Arterial Periférica/tratamiento farmacológico , Músculos , Resultado del Tratamiento , Método Doble Ciego
4.
MAGMA ; 36(6): 857-867, 2023 Dec.
Artículo en Inglés | MEDLINE | ID: mdl-37665502

RESUMEN

OBJECTIVE: To develop two spiral-based bSSFP pulse sequences combined with L + S reconstruction for accelerated ungated, free-breathing dynamic cardiac imaging at 1.5 T. MATERIALS AND METHODS: Tiny golden angle rotated spiral-out and spiral-in/out bSSFP sequences combined with view-sharing (VS), compressed sensing (CS), and low-rank plus sparse (L + S) reconstruction were evaluated and compared via simulation and in vivo dynamic cardiac imaging studies. The proposed methods were then validated against the standard cine, in terms of quantitative image assessment and qualitative quality rating. RESULTS: The L + S method yielded the least residual artifacts and the best image sharpness among the three methods. Both spiral cine techniques showed clinically diagnostic images (score > 3). Compared to standard cine, there were significant differences in global image quality and edge sharpness for spiral cine techniques, while there was significant difference in image contrast for the spiral-out cine but no significant difference for the spiral-in/out cine. There was good agreement in left ventricular ejection fraction for both the spiral-out cine (- 1.6 [Formula: see text] 3.1%) and spiral-in/out cine (- 1.5 [Formula: see text] 2.8%) against standard cine. DISCUSSION: Compared to the time-consuming standard cine (~ 5 min) which requires ECG-gating and breath-holds, the proposed spiral bSSFP sequences achieved ungated, free-breathing cardiac movies at a similar spatial (1.5 × 1.5 × 8 mm3) and temporal resolution (36 ms) per slice for whole heart coverage (10-15 slices) within 45 s, suggesting the clinical potential for improved patient comfort or for imaging patients with arrhythmias or who cannot hold their breath.


Asunto(s)
Corazón , Imagen por Resonancia Cinemagnética , Función Ventricular Izquierda , Humanos , Contencion de la Respiración , Corazón/diagnóstico por imagen , Imagen por Resonancia Magnética , Imagen por Resonancia Cinemagnética/métodos , Reproducibilidad de los Resultados , Volumen Sistólico
5.
MAGMA ; 36(3): 465-475, 2023 Jul.
Artículo en Inglés | MEDLINE | ID: mdl-37306784

RESUMEN

OBJECTIVE: Diagnostic-quality neuroimaging methods are vital for widespread clinical adoption of low field MRI. Spiral imaging is an efficient acquisition method that can mitigate the reduced signal-to-noise ratio at lower field strengths. As concomitant field artifacts are worse at lower field, we propose a generalizable quadratic gradient-field nulling as an echo-to-echo compensation and apply it to spiral TSE at 0.55 T. MATERIALS AND METHODS: A spiral in-out TSE acquisition was developed with a compensation for concomitant field variation between spiral interleaves, by adding bipolar gradients around each readout to minimize phase differences at each refocusing pulse. Simulations were performed to characterize concomitant field compensation approaches. We demonstrate our proposed compensation method in phantoms and (n = 8) healthy volunteers at 0.55 T. RESULTS: Spiral read-outs with integrated spoiling demonstrated strong concomitant field artifacts but were mitigated using the echo-to-echo compensation. Simulations predicted a decrease of concomitant field phase RMSE between echoes of 42% using the proposed compensation. Spiral TSE improved SNR by 17.2 ± 2.3% compared to reference Cartesian acquisition. DISCUSSION: We demonstrated a generalizable approach to mitigate concomitant field artifacts for spiral TSE acquisitions via the addition of quadratic-nulling gradients, which can potentially improve neuroimaging at low-field through increased acquisition efficiency.


Asunto(s)
Encéfalo , Aumento de la Imagen , Humanos , Aumento de la Imagen/métodos , Encéfalo/diagnóstico por imagen , Imagen por Resonancia Magnética/métodos , Neuroimagen/métodos , Relación Señal-Ruido , Artefactos
6.
Magn Reson Med ; 88(2): 601-616, 2022 08.
Artículo en Inglés | MEDLINE | ID: mdl-35394088

RESUMEN

PURPOSE: To develop a new approach to 2D turbo spin -echo (TSE) imaging using annular spiral rings with a retraced in/out trajectory, dubbed "SPRING-RIO TSE", for fast T2 -weighted brain imaging at 3T. METHODS: A long spiral trajectory was split into annular segmentations that were then incorporated into a 2D TSE acquisition module to fully exploit the sampling efficiency of spiral rings. A retraced in/out trajectory strategy coupled with spiral-ring TSE was introduced to increase SNR, mitigate T2 -decay induced artifacts, and self-correct moderate off-resonance while maintaining the target TE and causing no scan time penalty. Model-based k-space estimation and semiautomatic off-resonance correction algorithms were implemented to minimize effects of k-space trajectory infidelity and B0 inhomogeneity, respectively. The resulting SPRING-RIO TSE method was compared to the original spiral-ring (abbreviated "SPRING") TSE and Cartesian TSE using simulations, and phantom and in vivo acquisitions. RESULTS: Simulation and phantom studies demonstrated the performance of the proposed SPRING-RIO TSE pulses sequence, as well as that of trajectory correction and off-resonance correction. Volunteer data showed that the proposed method achieves high-quality 2D T2 -weighted brain imaging with a higher scan efficiency (0:45 min/14 slices versus 1:31 min/14 slices), improved image contrast, and reduced specific absorption rate compared to conventional 2D Cartesian TSE. CONCLUSION: 2D T2 -weighted brain imaging using spiral-ring TSE was implemented and tested, providing several potential advantages over conventional 2D Cartesian TSE imaging.


Asunto(s)
Aumento de la Imagen , Imagen por Resonancia Magnética , Artefactos , Encéfalo/diagnóstico por imagen , Humanos , Aumento de la Imagen/métodos , Imagenología Tridimensional/métodos , Imagen por Resonancia Magnética/métodos , Neuroimagen/métodos
7.
Magn Reson Med ; 85(5): 2686-2695, 2021 05.
Artículo en Inglés | MEDLINE | ID: mdl-33349950

RESUMEN

PURPOSE: Magnetization transfer ratio (MTR) histograms are used widely for the assessment of diffuse pathological changes in the brain. For broad clinical application, MTR scans should not only be fast, but confounding factors should also be minimized for high reproducibility. To this end, a 1-minute whole-brain spiral MTR method with intrinsic B1 -field correction is introduced. METHODS: A spiral multislice spoiled gradient-echo sequence with adaptable magnetization-transfer saturation pulses (angle ß) is proposed. After a low-resolution single-shot spiral readout and a dummy preparation period, high-resolution images are acquired using an interleaved spiral readout. For whole-brain MTR imaging, 50 interleaved slices with three different magnetization-transfer contrasts (ß = 0°, 350°, and 550°) together with an intrinsic B1 -field map are recorded in 58.5 seconds on a clinical 3T system. From the three contrasts, two sets of MTR images are derived and used for subsequent B1 correction, assuming a linear dependency on ß. For validation, a binary spin bath model is used. RESULTS: For the proposed B1 -correction scheme, numerical simulations indicate for brain tissue a decrease of about a factor of 10 for the B1 -related bias on MTR. As a result, following B1 correction, MTR differences in gray and white matter become markedly accentuated, and the reproducibility of MTR histograms from scan-rescan experiments is improved. Furthermore, B1 -corrected MTR histograms show a lower variability for age-matched normal-appearing brain tissue. CONCLUSION: From its speed and offering intrinsic B1 correction, the proposed method shows excellent prospects for clinical studies that explore magnetization-transfer effects based on MTR histogram analysis.


Asunto(s)
Encéfalo , Sustancia Blanca , Encéfalo/diagnóstico por imagen , Mapeo Encefálico , Imagen por Resonancia Magnética , Reproducibilidad de los Resultados
8.
Magn Reson Med ; 86(4): 2095-2104, 2021 10.
Artículo en Inglés | MEDLINE | ID: mdl-34021628

RESUMEN

PURPOSE: To use deep learning for suppression of the artifact-generating T1 -relaxation echo in cine displacement encoding with stimulated echoes (DENSE) for the purpose of reducing the scan time. METHODS: A U-Net was trained to suppress the artifact-generating T1 -relaxation echo using complementary phase-cycled data as the ground truth. A data-augmentation method was developed that generates synthetic DENSE images with arbitrary displacement-encoding frequencies to suppress the T1 -relaxation echo modulated for a range of frequencies. The resulting U-Net (DAS-Net) was compared with k-space zero-filling as an alternative method. Non-phase-cycled DENSE images acquired in shorter breath-holds were processed by DAS-Net and compared with DENSE images acquired with phase cycling for the quantification of myocardial strain. RESULTS: The DAS-Net method effectively suppressed the T1 -relaxation echo and its artifacts, and achieved root Mean Square(RMS) error = 5.5 ± 0.8 and structural similarity index = 0.85 ± 0.02 for DENSE images acquired with a displacement encoding frequency of 0.10 cycles/mm. The DAS-Net method outperformed zero-filling (root Mean Square error = 5.8 ± 1.5 vs 13.5 ± 1.5, DAS-Net vs zero-filling, P < .01; and structural similarity index = 0.83 ± 0.04 vs 0.66 ± 0.03, DAS-Net vs zero-filling, P < .01). Strain data for non-phase-cycled DENSE images with DAS-Net showed close agreement with strain from phase-cycled DENSE. CONCLUSION: The DAS-Net method provides an effective alternative approach for suppression of the artifact-generating T1 -relaxation echo in DENSE MRI, enabling a 42% reduction in scan time compared to DENSE with phase-cycling.


Asunto(s)
Artefactos , Aprendizaje Profundo , Contencion de la Respiración , Procesamiento de Imagen Asistido por Computador , Imagen por Resonancia Magnética , Imagen por Resonancia Cinemagnética
9.
Magn Reson Med ; 86(2): 648-662, 2021 08.
Artículo en Inglés | MEDLINE | ID: mdl-33709415

RESUMEN

PURPOSE: To develop and evaluate a high spatial resolution (1.25 × 1.25 mm2 ) spiral first-pass myocardial perfusion imaging technique with whole-heart coverage at 3T, to better assess transmural differences in perfusion between the endocardium and epicardium, to quantify the myocardial ischemic burden, and to improve the detection of obstructive coronary artery disease. METHODS: Whole-heart high-resolution spiral perfusion pulse sequences and corresponding motion-compensated reconstruction techniques for both interleaved single-slice (SS) and simultaneous multi-slice (SMS) acquisition with or without outer-volume suppression (OVS) were developed. The proposed techniques were evaluated in 34 healthy volunteers and 8 patients (55 data sets). SS and SMS images were reconstructed using motion-compensated L1-SPIRiT and SMS-Slice-L1-SPIRiT, respectively. Images were blindly graded by 2 experienced cardiologists on a 5-point scale (5, excellent; 1, poor). RESULTS: High-quality perfusion imaging was achieved for both SS and SMS acquisitions with or without OVS. The SS technique without OVS had the highest scores (4.5 [4, 5]), which were greater than scores for SS with OVS (3.5 [3.25, 3.75], P < .05), MB = 2 without OVS (3.75 [3.25, 4], P < .05), and MB = 2 with OVS (3.75 [2.75, 4], P < .05), but significantly higher than those for MB = 3 without OVS (4 [4, 4], P = .95). SMS image quality was improved using SMS-Slice-L1-SPIRiT as compared to SMS-L1-SPIRiT (P < .05 for both reviewers). CONCLUSION: We demonstrated the successful implementation of whole-heart spiral perfusion imaging with high resolution at 3T. Good image quality was achieved, and the SS without OVS showed the best image quality. Evaluation in patients with expected ischemic heart disease is warranted.


Asunto(s)
Imagen de Perfusión Miocárdica , Humanos , Procesamiento de Imagen Asistido por Computador , Movimiento (Física) , Imagen de Perfusión , Pericardio
10.
Magn Reson Med ; 85(4): 2145-2159, 2021 04.
Artículo en Inglés | MEDLINE | ID: mdl-33174639

RESUMEN

PURPOSE: Intraoperative T2 -weighted (T2-w) imaging unreliably captures image contrast specific to thermal ablation after transcranial MR-guided focused ultrasound surgery, impeding dynamic imaging feedback. Using a porcine thalamotomy model, we test the unproven hypothesis that intraoperative DWI can improve dynamic feedback by detecting lesioning within 30 minutes of transcranial MR-guided focused ultrasound surgery. METHODS: Twenty-five thermal lesions were formed in six porcine models using a clinical transcranial MR-guided focused ultrasound surgery system. A novel diffusion-weighted pulse sequence monitored the formation of T2-w and diffusion-weighted lesion contrast after ablation. Using postoperative T2-w contrast to indicate lesioning, apparent intraoperative image contrasts and diffusion coefficients at each lesion site were computed as a function of time after ablation, observed peak temperature, and observed thermal dose. Lesion sizes segmented from imaging and thermometry were compared. Image reviewers estimated the time to emergence of lesion contrast. Intraoperative image contrasts were analyzed using receiver operator curves. RESULTS: On average, the apparent diffusion coefficient at lesioned sites decreased within 5 minutes after ablation relative to control sites. In-plane lesion areas on intraoperative DWI varied from postoperative T2-w MRI and MR thermometry by 9.6±9.7 mm2 and -4.0±7.1 mm2 , respectively. The 0.25, 0.5, and 0.75 quantiles of the earliest times of observed T2-w and diffusion-weighted lesion contrast were 10.7, 21.0, and 27.8 minutes and 3.7, 8.6, and 11.8 minutes, respectively. The T2-w and diffusion-weighted contrasts and apparent diffusion coefficient values produced areas under the receiver operator curve of 0.66, 0.80, and 0.74, respectively. CONCLUSION: Intraoperative DWI can detect MR-guided focused ultrasound surgery lesion formation in the brain within several minutes after treatment.


Asunto(s)
Hipertermia Inducida , Cirugía Asistida por Computador , Animales , Imagen de Difusión por Resonancia Magnética , Imagen por Resonancia Magnética , Porcinos , Tálamo
11.
J Magn Reson Imaging ; 54(4): 1268-1279, 2021 10.
Artículo en Inglés | MEDLINE | ID: mdl-33822426

RESUMEN

BACKGROUND: Variable density spiral (VDS) pulse sequences with motion compensated compressed sensing (MCCS) reconstruction allow for whole-heart quantitative assessment of myocardial perfusion but are not clinically validated. PURPOSE: Assess performance of whole-heart VDS quantitative stress perfusion with MCCS to detect obstructive coronary artery disease (CAD). STUDY TYPE: Prospective cross sectional. POPULATION: Twenty-five patients with chest pain and known or suspected CAD and nine normal subjects. FIELD STRENGTH/SEQUENCE: Segmented steady-state free precession (SSFP) sequence, segmented phase sensitive inversion recovery sequence for late gadolinium enhancement (LGE) imaging and VDS sequence at 1.5 T for rest and stress quantitative perfusion at eight short-axis locations. ASSESSMENT: Stenosis was defined as ≥50% by quantitative coronary angiography (QCA). Visual and quantitative analysis of MRI data was compared to QCA. Quantitative analysis assessed average myocardial perfusion reserve (MPR), average stress myocardial blood flow (MBF), and lowest stress MBF of two contiguous myocardial segments. Ischemic burden was measured visually and quantitatively. STATISTICAL TESTS: Student's t-test, McNemar's test, chi-square statistic, linear mixed-effects model, and area under receiver-operating characteristic curve (ROC). RESULTS: Per-patient visual analysis demonstrated a sensitivity of 84% (95% confidence interval [CI], 60%-97%) and specificity of 83% [95% CI, 36%-100%]. There was no significant difference between per-vessel visual and quantitative analysis for sensitivity (69% [95% CI, 51%-84%] vs. 77% [95% CI, 60%-90%], P = 0.39) and specificity (88% [95% CI, 73%-96%] vs. 80% [95% CI, 64%-91%], P = 0.75). Per-vessel quantitative analysis ROC showed no significant difference (P = 0.06) between average MPR (0.68 [95% CI, 0.56-0.81]), average stress MBF (0.74 [95% CI, 0.63-0.86]), and lowest stress MBF (0.79 [95% CI, 0.69-0.90]). Visual and quantitative ischemic burden measurements were comparable (P = 0.85). DATA CONCLUSION: Whole-heart VDS stress perfusion demonstrated good diagnostic accuracy and ischemic burden evaluation. No significant difference was seen between visual and quantitative diagnostic performance and ischemic burden measurements. EVIDENCE LEVEL: 2 TECHNICAL EFFICACY: Stage 2.


Asunto(s)
Adenosina , Medios de Contraste , Estudios Transversales , Gadolinio , Humanos , Espectroscopía de Resonancia Magnética , Valor Predictivo de las Pruebas , Estudios Prospectivos
12.
J Cardiovasc Magn Reson ; 23(1): 20, 2021 03 11.
Artículo en Inglés | MEDLINE | ID: mdl-33691739

RESUMEN

BACKGROUND: Cardiovascular magnetic resonance (CMR) cine displacement encoding with stimulated echoes (DENSE) measures heart motion by encoding myocardial displacement into the signal phase, facilitating high accuracy and reproducibility of global and segmental myocardial strain and providing benefits in clinical performance. While conventional methods for strain analysis of DENSE images are faster than those for myocardial tagging, they still require manual user assistance. The present study developed and evaluated deep learning methods for fully-automatic DENSE strain analysis. METHODS: Convolutional neural networks (CNNs) were developed and trained to (a) identify the left-ventricular (LV) epicardial and endocardial borders, (b) identify the anterior right-ventricular (RV)-LV insertion point, and (c) perform phase unwrapping. Subsequent conventional automatic steps were employed to compute strain. The networks were trained using 12,415 short-axis DENSE images from 45 healthy subjects and 19 heart disease patients and were tested using 10,510 images from 25 healthy subjects and 19 patients. Each individual CNN was evaluated, and the end-to-end fully-automatic deep learning pipeline was compared to conventional user-assisted DENSE analysis using linear correlation and Bland Altman analysis of circumferential strain. RESULTS: LV myocardial segmentation U-Nets achieved a DICE similarity coefficient of 0.87 ± 0.04, a Hausdorff distance of 2.7 ± 1.0 pixels, and a mean surface distance of 0.41 ± 0.29 pixels in comparison with manual LV myocardial segmentation by an expert. The anterior RV-LV insertion point was detected within 1.38 ± 0.9 pixels compared to manually annotated data. The phase-unwrapping U-Net had similar or lower mean squared error vs. ground-truth data compared to the conventional path-following method for images with typical signal-to-noise ratio (SNR) or low SNR (p < 0.05), respectively. Bland-Altman analyses showed biases of 0.00 ± 0.03 and limits of agreement of - 0.04 to 0.05 or better for deep learning-based fully-automatic global and segmental end-systolic circumferential strain vs. conventional user-assisted methods. CONCLUSIONS: Deep learning enables fully-automatic global and segmental circumferential strain analysis of DENSE CMR providing excellent agreement with conventional user-assisted methods. Deep learning-based automatic strain analysis may facilitate greater clinical use of DENSE for the quantification of global and segmental strain in patients with cardiac disease.


Asunto(s)
Aprendizaje Profundo , Cardiopatías/diagnóstico por imagen , Interpretación de Imagen Asistida por Computador , Imagen por Resonancia Cinemagnética , Función Ventricular Izquierda , Función Ventricular Derecha , Automatización , Estudios de Casos y Controles , Cardiopatías/fisiopatología , Humanos , Londres , Valor Predictivo de las Pruebas , Estados Unidos
13.
Magn Reson Med ; 83(4): 1235-1249, 2020 04.
Artículo en Inglés | MEDLINE | ID: mdl-31565819

RESUMEN

PURPOSE: Spiral MRI has advantages for cardiac imaging, and multiband (MB) spiral MRI of the heart shows promise. However, current reconstruction methods for MB spiral imaging have limitations. We sought to develop improved reconstruction methods for MB spiral cardiac MRI. METHODS: Two reconstruction methods were developed. The first is non-Cartesian slice-GRAPPA (NCSG), which uses phase demodulation and gridding operations before application of a Cartesian slice-separating kernel. The second method, slice-SPIRiT, formulates the reconstruction as a minimization problem that enforces in-plane coil consistency and consistency with the acquired MB data, and uses through-plane coil sensitivity information in the iterative solution. These methods were compared with conjugate-gradient SENSE in phantoms and volunteers. Temporal alternation of CAIPIRINHA (controlled aliasing in parallel imaging results in higher acceleration) phase and the use of a temporal filter were also investigated. RESULTS: Phantom experiments with 3 simultaneous slices (MB = 3) showed that mean artifact power was highest for conjugate-gradient SENSE, lower for NCSG, and lowest for slice-SPIRiT. For volunteer cine imaging (MB = 3, N = 5), the artifact power was 0.182 ± 0.037, 0.148 ± 0.036, and 0.139 ± 0.034 for conjugate-gradient SENSE, NCSG, and slice-SPIRiT, respectively (P < .05, analysis of variance). Temporal alternation of CAIPIRINHA reduced artifacts for both NCSG and slice-SPIRiT. CONCLUSION: The NCSG and slice-SPIRiT methods provide more accurate reconstructions for MB spiral cine imaging compared with conjugate-gradient SENSE. These methods hold promise for non-Cartesian MB imaging.


Asunto(s)
Algoritmos , Aumento de la Imagen , Artefactos , Humanos , Procesamiento de Imagen Asistido por Computador , Imagen por Resonancia Magnética , Fantasmas de Imagen
14.
J Strength Cond Res ; 34(3): 623-631, 2020 Mar.
Artículo en Inglés | MEDLINE | ID: mdl-31703044

RESUMEN

Xie, T, Crump, KB, Ni, R, Meyer, CH, Hart, JM, Blemker, SS, and Feng, X. Quantitative relationships between individual lower-limb muscle volumes and jump and sprint performances of basketball players. J Strength Cond Res 34(3): 623-631, 2020-Lower body skeletal muscles play an essential role in athletic performance; however, because of the difficulty in obtaining detailed information of each individual muscle, the quantitative relationships between individual muscle volumes and performance are not well studied. The aim of this study was to accurately measure individual muscle volumes and identify the muscles with strong correlations with jump and sprint performance metrics for basketball players. Ten male varsity basketball players and 8 club players were scanned using magnetic resonance imaging (MRI) and instructed to perform various jump and sprint tests. The volumes of all lower-limb muscles were calculated from MRI and normalized by body surface area to reduce the effect of the body size differences. In analysis, feature selection was first used to identify the most relevant muscles, followed by correlation analysis to quantify the relationships between the selected muscles and each performance metric. Vastus medialis and semimembranosus were found to be the most relevant muscles for jump while adductor longus and vastus medialis were selected for sprint. Strong correlations (r = 0.664-0.909) between the selected muscles and associated performance tests were found for varsity players, and moderate correlations (r = -0.203 to 0.635) were found for club players. One possible application is that for well-trained varsity players, a targeted training scheme focusing on the selected muscles may be an effective method to further improve jump and sprint performances.


Asunto(s)
Rendimiento Atlético/fisiología , Baloncesto/fisiología , Extremidad Inferior/fisiología , Fuerza Muscular/fisiología , Músculo Esquelético/fisiología , Adolescente , Humanos , Masculino , Músculo Cuádriceps/fisiología , Carrera/fisiología , Adulto Joven
15.
Magn Reson Med ; 81(3): 1876-1889, 2019 03.
Artículo en Inglés | MEDLINE | ID: mdl-30417936

RESUMEN

PURPOSE: Variable flip angle (VFA)-based T1 quantification techniques are highly sensitive to B1 inhomogeneities and to residual T2 dependency arising from incomplete spoiling. Here, a rapid spiral VFA acquisition scheme with high spoiling efficiency is proposed for simultaneous whole-brain B1 and T1 mapping. METHODS: VFA acquisitions at 2 different flip angles are performed to quantify T1 using a steady-state prepared spiral 2D multislice spoiled gradient-echo sequence with the acquisition of 10 and 20 spiral interleaves at 1.5T and 3T, respectively. Additionally, parallel imaging acceleration of factor 2 is investigated at 3T. The free induction decay induced by the preparation pulse is sampled by a single-shot spiral readout to quantify B1 . RESULTS: The in vitro and in vivo validations yielded good agreement between the derived spiral VFA B1 and the acquired reference B1 maps as well as between the B1 -corrected spiral VFA T1 and the reference T1 maps. The spiral VFA acquisitions in the human brain delivered artifact-free B1 and T1 maps and demonstrated high reproducibility at 1.5T and 3T. CONCLUSION: Reliable simultaneous spiral VFA B1 and T1 quantification was feasible with acquisition times of <1 min for whole-brain coverage at clinically relevant resolution.


Asunto(s)
Mapeo Encefálico/métodos , Encéfalo/diagnóstico por imagen , Procesamiento de Imagen Asistido por Computador/métodos , Imagen por Resonancia Magnética/métodos , Adulto , Algoritmos , Artefactos , Simulación por Computador , Femenino , Sustancia Gris/diagnóstico por imagen , Humanos , Imagenología Tridimensional/métodos , Masculino , Fantasmas de Imagen , Protones , Reproducibilidad de los Resultados , Sustancia Blanca/diagnóstico por imagen
16.
Magn Reson Med ; 81(3): 1806-1817, 2019 03.
Artículo en Inglés | MEDLINE | ID: mdl-30421451

RESUMEN

PURPOSE: Images acquired with spiral k-space trajectories can suffer from off-resonance image blur. Previous work showed that averaging 2 images acquired with a retraced, in/out (RIO) trajectory self-corrects image blur so long as off-resonant spins accrue less than 1 half-cycle of relative phase over the readout. Practical scenarios frequently exceed this threshold. Here, we derive and characterize a more-robust off-resonance image blur correction method for RIO acquisitions. METHODS: Phantom and human volunteer data were acquired using a RIO trajectory with readout durations ranging from 4 to 60 ms. The resulting images were deblurred using 3 candidate methods: conventional linear correction of the component images; semiautomatic deblurring of the component images using an established minimized phase objective function; and semiautomatic deblurring of the average of the component images using a maximized energy objective function, derived below. Deblurring errors were estimated relative to images acquired with 4 ms readouts. RESULTS: All 3 methods converged to similar solutions in cases where less than 2 and 4 cycles of phase accrued over the readout in in vivo and phantom images, respectively (<13 ms readout at 3T). Above this threshold, the linear and minimized phase methods introduced several errors. The maximized energy function provided accurate deblurring so long as less than 6 and 10 cycles of phase accrued over the readout in in vivo and phantom images, respectively (<34 ms readout at 3T). CONCLUSION: The maximized energy objective function can accurately deblur RIO acquisitions over a wide spectrum of off resonance frequencies.


Asunto(s)
Encéfalo/diagnóstico por imagen , Procesamiento de Imagen Asistido por Computador/métodos , Imagen por Resonancia Magnética , Algoritmos , Artefactos , Simulación por Computador , Humanos , Aumento de la Imagen/métodos , Modelos Estadísticos , Reconocimiento de Normas Patrones Automatizadas , Fantasmas de Imagen
17.
Magn Reson Med ; 81(2): 852-862, 2019 02.
Artículo en Inglés | MEDLINE | ID: mdl-30311689

RESUMEN

PURPOSE: To develop and evaluate a simultaneous multislice (SMS) spiral perfusion pulse sequence with whole-heart coverage. METHODS: An orthogonal set of phase cycling angles following a Hadamard pattern was incorporated into a golden-angle (GA) variable density spiral perfusion sequence to perform SMS imaging at different multiband (MB) factors. Images were reconstructed using an SMS extension of L1-SPIRiT that we have termed SMS-L1-SPIRiT. The proposed sequence was evaluated in 40 subjects (10 each for MB factors of 1, 2, 3, and 4). Images were blindly graded by 2 cardiologists on a 5-point scale (5, excellent). To quantitatively evaluate the reconstruction performance against images acquired without SMS, the MB =1 data were used to retrospectively simulate data acquired at MB factors of 2 to 4. RESULTS: Analysis of the SMS point-spread function for the desired slice showed that the proposed sampling strategy significantly canceled the main-lobe energy of the other slices and has low side-lobe energy resulting in an incoherent temporal aliasing pattern when rotated by the GA. Retrospective experiments demonstrated the SMS-L1-SPIRiT method removed aliasing from the interfering slices and showed excellent agreement with the ground-truth MB =1 images. Clinical evaluation demonstrated high-quality perfusion images with average image-quality scores of 4.3 ± 0.5 (MB =2), 4.2 ± 0.5 (MB =3), and 4.4 ± 0.4 (MB =4) with no significant quality difference in image quality between MB factors (P = 0.38). CONCLUSION: SMS spiral perfusion at MB factors 2, 3, and 4 produces high-quality perfusion images with whole-heart coverage in a clinical setting with high sampling efficiency.


Asunto(s)
Corazón/diagnóstico por imagen , Aumento de la Imagen/métodos , Interpretación de Imagen Asistida por Computador/métodos , Imagen de Perfusión Miocárdica , Adulto , Algoritmos , Arritmias Cardíacas/diagnóstico por imagen , Fibrilación Atrial/diagnóstico por imagen , Cardiomiopatías/diagnóstico por imagen , Cardiomiopatía Hipertrófica/diagnóstico por imagen , Simulación por Computador , Femenino , Humanos , Persona de Mediana Edad , Infarto del Miocardio/diagnóstico por imagen , Miocarditis/diagnóstico por imagen , Variaciones Dependientes del Observador , Pericardio/diagnóstico por imagen , Reproducibilidad de los Resultados , Estudios Retrospectivos , Taquicardia Ventricular/diagnóstico por imagen , Disfunción Ventricular Derecha/diagnóstico por imagen , Complejos Prematuros Ventriculares/diagnóstico por imagen
18.
Magn Reson Med ; 80(4): 1467-1474, 2018 10.
Artículo en Inglés | MEDLINE | ID: mdl-29508458

RESUMEN

PURPOSE: To develop a real-time dynamic MRI method for comprehensive evaluation of velum movement during speech. METHODS: Dynamic MRI has been used to study velopharyngeal insufficiency (VPI) by imaging the movement of the velum during speech, because it can provide good anatomic details with no exposed radiation. To be able to comprehensively evaluate dynamic velum movement, a real-time spiral non-balanced SSFP sequence was developed with simultaneous dual-planar coverage and improved spatial and temporal resolution using a combination of parallel imaging and spatial and temporal compressed sensing to achieve 6 × acceleration. New off-resonance correction and post-processing methods were also developed to reduce blurring and slice crosstalk. RESULTS: The method demonstrated good image quality for visualizing dynamic velum movement with reduced blurring and improved image homogeneity. Spatial resolution of 1.2*1.2 mm2 with 150 mm FOV and temporal resolution of 20 frames-per-second with simultaneous dual-planar coverage was achieved. CONCLUSIONS: This work describes a new technique for studying speech disorders using dual-planar accelerated spiral dynamic MRI.


Asunto(s)
Procesamiento de Imagen Asistido por Computador/métodos , Imagen por Resonancia Magnética/métodos , Paladar Blando/diagnóstico por imagen , Insuficiencia Velofaríngea/diagnóstico por imagen , Humanos , Movimiento/fisiología , Habla/fisiología
19.
Magn Reson Med ; 79(6): 3122-3127, 2018 06.
Artículo en Inglés | MEDLINE | ID: mdl-29115692

RESUMEN

PURPOSE: To develop a rapid pulse sequence for volumetric MR thermometry. METHODS: Simulations were carried out to assess temperature deviation, focal spot distortion/blurring, and focal spot shift across a range of readout durations and maximum temperatures for Cartesian, spiral-out, and retraced spiral-in/out (RIO) trajectories. The RIO trajectory was applied for stack-of-spirals 3D imaging on a real-time imaging platform and preliminary evaluation was carried out compared to a standard 2D sequence in vivo using a swine brain model, comparing maximum and mean temperatures measured between the two methods, as well as the temporal standard deviation measured by the two methods. RESULTS: In simulations, low-bandwidth Cartesian trajectories showed substantial shift of the focal spot, whereas both spiral trajectories showed no shift while maintaining focal spot geometry. In vivo, the 3D sequence achieved real-time 4D monitoring of thermometry, with an update time of 2.9-3.3 s. CONCLUSION: Spiral imaging, and RIO imaging in particular, is an effective way to speed up volumetric MR thermometry. Magn Reson Med 79:3122-3127, 2018. © 2017 International Society for Magnetic Resonance in Medicine.


Asunto(s)
Procesamiento de Imagen Asistido por Computador/métodos , Imagen por Resonancia Magnética/métodos , Termometría/métodos , Animales , Encéfalo/diagnóstico por imagen , Simulación por Computador , Fantasmas de Imagen , Porcinos
20.
Magn Reson Med ; 79(1): 208-216, 2018 Jan.
Artículo en Inglés | MEDLINE | ID: mdl-28321908

RESUMEN

PURPOSE: To develop a single-shot spiral perfusion pulse sequence with outer-volume suppression (OVS) to achieve whole-heart coverage with a short temporal footprint of 10 ms per slice location. METHODS: A highly accelerated single-shot variable density spiral pulse sequence with an integrated OVS module for reduced field of view (rFOV) perfusion imaging with 2 mm spatial resolution was developed and evaluated in simulations, phantom experiments and in clinical patients with (n = 8) or without (n = 8) OVS. Images were reconstructed by block low-rank sparsity with motion guidance (BLOSM) and graded by two cardiologists on a 5-point scale (1, excellent; 5, poor). RESULTS: Simulation and phantom results showed that OVS effectively suppressed the signal outside the desired field of view (FOV). Clinical patient data demonstrated high quality perfusion images with rFOV. The average image quality scores of full FOV cases and rFOV cases were 3.1 ± 0.64 and 2.3 ± 0.46, respectively, (P = 0.02) from cardiologist 1 and 2.5 ± 0.54 and 1.8 ± 0.47, respectively, (P = 0.04) from cardiologist 2, showing superior image quality for the rFOV images compared with the full FOV images. CONCLUSION: A single-shot spiral perfusion sequence that uses OVS and BLOSM performs perfusion imaging with a very short temporal footprint per image supporting whole-heart coverage with good image quality. Magn Reson Med 79:208-216, 2018. © 2017 International Society for Magnetic Resonance in Medicine.


Asunto(s)
Angina de Pecho/diagnóstico por imagen , Imagen de Perfusión Miocárdica/métodos , Algoritmos , Artefactos , Cardiología , Simulación por Computador , Humanos , Aumento de la Imagen/métodos , Interpretación de Imagen Asistida por Computador/métodos , Procesamiento de Imagen Asistido por Computador , Modelos Estadísticos , Movimiento (Física) , Variaciones Dependientes del Observador , Imagen de Perfusión , Fantasmas de Imagen