Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 2 de 2
Filtrar
Más filtros

Bases de datos
Tipo de estudio
Tipo del documento
País de afiliación
Intervalo de año de publicación
1.
Environ Sci Technol ; 52(6): 3567-3573, 2018 03 20.
Artículo en Inglés | MEDLINE | ID: mdl-29470061

RESUMEN

Metal contamination of natural and drinking water systems poses hazards to public and environmental health. Quantifying metal concentrations in water typically requires sample collection in the field followed by expensive laboratory analysis that can take days to weeks to obtain results. The objective of this work was to develop a low-cost, field-deployable method to quantify trace levels of copper in drinking water by coupling solid-phase extraction/preconcentration with a microfluidic paper-based analytical device. This method has the advantages of being hand-powered (instrument-free) and using a simple "read by eye" quantification motif (based on color distance). Tap water samples collected across Fort Collins, CO, were tested with this method and validated against ICP-MS. We demonstrate the ability to quantify the copper content of tap water within 30% of a reference technique at levels ranging from 20 to 500 000 ppb. The application of this technology, which should be sufficient as a rapid screening tool, can lead to faster, more cost-effective detection of soluble metals in water systems.


Asunto(s)
Agua Potable , Contaminantes Químicos del Agua , Cobre , Agua Dulce , Extracción en Fase Sólida
2.
Environ Sci Technol ; 52(19): 11267-11275, 2018 10 02.
Artículo en Inglés | MEDLINE | ID: mdl-30200753

RESUMEN

Traditional methods for measuring personal exposure to fine particulate matter (PM2.5) are cumbersome and lack spatiotemporal resolution; methods that are time-resolved are limited to a single species/component of PM. To address these limitations, we developed an automated microenvironmental aerosol sampler (AMAS), capable of resolving personal exposure by microenvironment. The AMAS is a wearable device that uses a GPS sensor algorithm in conjunction with a custom valve manifold to sample PM2.5 onto distinct filter channels to evaluate home, school, and other (e.g., outdoors, in transit, etc.) exposures. Pilot testing was conducted in Fresno, CA where 25 high-school participants ( n = 37 sampling events) wore an AMAS for 48-h periods in November 2016. Data from 20 (54%) of the 48-h samples collected by participants were deemed valid and the filters were analyzed for PM2.5 black carbon (BC) using light transmissometry and aerosol oxidative potential (OP) using the dithiothreitol (DTT) assay. The amount of inhaled PM2.5 was calculated for each microenvironment to evaluate the health risks associated with exposure. On average, the estimated amount of inhaled PM2.5 BC (µg day-1) and OP [(µM min-1) day-1] was greatest at home, owing to the proportion of time spent within that microenvironment. Validation of the AMAS demonstrated good relative precision (8.7% among collocated instruments) and a mean absolute error of 22% for BC and 33% for OP when compared to a traditional personal sampling instrument. This work demonstrates the feasibility of new technology designed to quantify personal exposure to PM2.5 species within distinct microenvironments.


Asunto(s)
Contaminantes Atmosféricos , Monitoreo del Ambiente , Aerosoles , Carbono , Estrés Oxidativo , Material Particulado
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA