Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 11 de 11
Filtrar
1.
Nature ; 565(7739): 361-365, 2019 01.
Artículo en Inglés | MEDLINE | ID: mdl-30602791

RESUMEN

The fast-growing field of bioelectronic medicine aims to develop engineered systems that can relieve clinical conditions by stimulating the peripheral nervous system1-5. This type of technology relies largely on electrical stimulation to provide neuromodulation of organ function or pain. One example is sacral nerve stimulation to treat overactive bladder, urinary incontinence and interstitial cystitis (also known as bladder pain syndrome)4,6,7. Conventional, continuous stimulation protocols, however, can cause discomfort and pain, particularly when treating symptoms that can be intermittent (for example, sudden urinary urgency)8. Direct physical coupling of electrodes to the nerve can lead to injury and inflammation9-11. Furthermore, typical therapeutic stimulators target large nerve bundles that innervate multiple structures, resulting in a lack of organ specificity. Here we introduce a miniaturized bio-optoelectronic implant that avoids these limitations by using (1) an optical stimulation interface that exploits microscale inorganic light-emitting diodes to activate opsins; (2) a soft, high-precision biophysical sensor system that allows continuous measurements of organ function; and (3) a control module and data analytics approach that enables coordinated, closed-loop operation of the system to eliminate pathological behaviours as they occur in real-time. In the example reported here, a soft strain gauge yields real-time information on bladder function in a rat model. Data algorithms identify pathological behaviour, and automated, closed-loop optogenetic neuromodulation of bladder sensory afferents normalizes bladder function. This all-optical scheme for neuromodulation offers chronic stability and the potential to stimulate specific cell types.


Asunto(s)
Neuronas/fisiología , Optogenética/instrumentación , Optogenética/métodos , Vejiga Urinaria/inervación , Vejiga Urinaria/fisiología , Tecnología Inalámbrica/instrumentación , Algoritmos , Animales , Células Cultivadas , Electrónica , Femenino , Ganglios Espinales/citología , Humanos , Neuronas/citología , Ratas , Ratas Sprague-Dawley , Raíces Nerviosas Espinales/citología
2.
Nano Lett ; 21(19): 8385-8392, 2021 10 13.
Artículo en Inglés | MEDLINE | ID: mdl-34606292

RESUMEN

The microbolometer is the cornerstone device for imaging in the long-wavelength infrared range (LWIR) at room temperature. The state-of-the-art commercial microbolometers usually have a large thermal time constant (TTC) of over 10 ms, limited by their substantial device heat capacity. Moreover, the minimal pixel size of state-of-the-art bolometer is around 10 µm by 10 µm to ensure sufficient power absorption per pixel. Here, we demonstrate an ultrafast silicon nanomembrane microbolometer with a small heat capacity of around 1.9 × 10-11J/K, which allows for its operation at a speed of over 10 kHz, corresponding to a TTC of less than 16 µs. Moreover, a compact diabolo antenna is leveraged for efficient LWIR light absorption, enabling the downscaling of the active area size to 6.2 µm by 6.2 µm. Because of the complementary metal oxide semiconductor (CMOS)-compatible fabrication processes, our demonstration here may lead to a future high-resolution and high-speed LWIR imaging solution.


Asunto(s)
Semiconductores , Silicio , Rayos Infrarrojos , Óxidos
3.
ACS Appl Mater Interfaces ; 16(4): 4896-4903, 2024 Jan 31.
Artículo en Inglés | MEDLINE | ID: mdl-38252593

RESUMEN

Radio frequency (RF) electronics are vital components of stretchable electronics that require wireless capabilities, ranging from skin-interfaced wearable systems to implantable devices to soft robotics. One of the key challenges in stretchable electronics is achieving near-lossless transmission line technology that can carry high-frequency electrical signals between various RF components. Almost all existing stretchable interconnection strategies only demonstrate direct current or low-frequency electrical properties, limiting their use in high frequencies, especially in the MHz to GHz range. Here, we describe the design and fabrication of a simple stretchable RF transmission line strategy that integrates a quasi-microstrip structure into a stretchable serpentine microscale interconnection. We show the effects of quasi-microstrip structural dimensions on the RF performance based on detailed quantitative analysis and experimentally demonstrate the optimized device capable of carrying RF signals with frequencies of up to 40 GHz with near-lossless characteristics. To show the potential application of our transmission line in stretchable microwave electronics, we designed a single-stage power amplifier system with a gain of 9.8 dB at 9 GHz that fully utilizes our quasi-microstrip transmission line technology.

4.
Bioact Mater ; 30: 142-153, 2023 Dec.
Artículo en Inglés | MEDLINE | ID: mdl-37575875

RESUMEN

Age-related macular degeneration (AMD) causes blindness due to loss of retinal pigment epithelium (RPE) and photoreceptors (PRs), which comprise the two outermost layers of the retina. Given the small size of the macula and the importance of direct contact between RPE and PRs, the use of scaffolds for targeted reconstruction of the outer retina in later stage AMD and other macular dystrophies is particularly attractive. We developed microfabricated, honeycomb-patterned, biodegradable poly(glycerol sebacate) (PGS) scaffolds to deliver organized, adjacent layers of RPE and PRs to the subretinal space. Furthermore, an optimized process was developed to photocure PGS, shortening scaffold production time from days to minutes. The resulting scaffolds robustly supported the seeding of human pluripotent stem cell-derived RPE and PRs, either separately or as a dual cell-layered construct. These advanced, economical, and versatile scaffolds can accelerate retinal cell transplantation efforts and benefit patients with AMD and other retinal degenerative diseases.

5.
ACS Appl Mater Interfaces ; 13(21): 25053-25063, 2021 Jun 02.
Artículo en Inglés | MEDLINE | ID: mdl-34018738

RESUMEN

To fulfill the increasing demand for radiofrequency (RF) wireless communication capacity for epidermal electronics, stretchable integrated circuits (ICs) in the gigahertz (GHz) range are desirable. Lumped RF inductors, as a key component in RFICs, typically dominate a large portion of the circuit/chip area and therefore make such inductors mechanically stretchable is critical for GHz-frequency stretchable RFICs. Most of the reported stretchable inductors operate in the MHz frequency range. The only GHz stretchable inductor shows a quality factor of about 2, limiting its potential RF applications. Here, stretchable inductors with a high quality factor of Q > 12.6 and resonance operation frequency of fres > 11.6 GHz are demonstrated by combining microspirals with stretchable structures, overcoming all of the shortcomings of previous demonstrations. Furthermore, a stretchable 1.5-2.6 GHz filter with a peak insertion loss of -2.3 dB at 1.8 GHz is developed, showing negligible performance changes under stretching or on the skin to demonstrate the utility in practical wireless applications like GSM and Bluetooth (2.45 GHz) bands. The demonstrations can facilitate multiple GHz epidermal RFICs in the future.


Asunto(s)
Epidermis , Dispositivos Electrónicos Vestibles , Humanos , Tecnología Inalámbrica
6.
Nat Commun ; 11(1): 3118, 2020 06 19.
Artículo en Inglés | MEDLINE | ID: mdl-32561743

RESUMEN

Low-cost flexible microwave circuits with compact size and light weight are highly desirable for flexible wireless communication and other miniaturized microwave systems. However, the prevalent studies on flexible microwave electronics have only focused on individual flexible microwave elements such as transistors, inductors, capacitors, and transmission lines. Thinning down supporting substrate of rigid chip-based monolithic microwave integrated circuits has been the only approach toward flexible microwave integrated circuits. Here, we report a flexible microwave integrated circuit strategy integrating membrane AlGaN/GaN high electron mobility transistor with passive impedance matching networks on cellulose nanofibril paper. The strategy enables a heterogeneously integrated and, to our knowledge, the first flexible microwave amplifier that can output 10 mW power beyond 5 GHz and can also be easily disposed of due to the use of cellulose nanofibril paper as the circuit substrate. The demonstration represents a critical step forward in realizing flexible wireless communication devices.

7.
Sci Transl Med ; 12(538)2020 04 08.
Artículo en Inglés | MEDLINE | ID: mdl-32269166

RESUMEN

Long-lasting, high-resolution neural interfaces that are ultrathin and flexible are essential for precise brain mapping and high-performance neuroprosthetic systems. Scaling to sample thousands of sites across large brain regions requires integrating powered electronics to multiplex many electrodes to a few external wires. However, existing multiplexed electrode arrays rely on encapsulation strategies that have limited implant lifetimes. Here, we developed a flexible, multiplexed electrode array, called "Neural Matrix," that provides stable in vivo neural recordings in rodents and nonhuman primates. Neural Matrix lasts over a year and samples a centimeter-scale brain region using over a thousand channels. The long-lasting encapsulation (projected to last at least 6 years), scalable device design, and iterative in vivo optimization described here are essential components to overcoming current hurdles facing next-generation neural technologies.


Asunto(s)
Mapeo Encefálico , Roedores , Animales , Encéfalo , Electrodos Implantados , Microelectrodos , Primates
8.
Immune Netw ; 18(2): e17, 2018 Apr.
Artículo en Inglés | MEDLINE | ID: mdl-29732235

RESUMEN

Tuberculosis (TB) is a contagious disease that has been responsible for the death of one billion people in the last 200 years. Until now, the only vaccine approved for the prevention of TB is Bacillus Calmette-Guérin (BCG), which is prepared by attenuating Mycobacterium bovis. However, one of the limitations of BCG is that its preventive effect against pulmonary TB varies from person to person. Therefore, there arises a need for a new TB vaccine to replace or supplement BCG. In this review, we have summarized the findings of current clinical trials on preventive and therapeutic TB vaccine candidates. In addition, we have discussed a novel vaccination approach using the cell-based vaccine presenting early secretory antigenic target-6 (ESAT-6), which is a potent immunogenic antigen. The role of ESAT-6 in hosts has also been described.

9.
Sci Transl Med ; 10(435)2018 04 04.
Artículo en Inglés | MEDLINE | ID: mdl-29618561

RESUMEN

Thin, soft, skin-like sensors capable of precise, continuous measurements of physiological health have broad potential relevance to clinical health care. Use of sensors distributed over a wide area for full-body, spatiotemporal mapping of physiological processes would be a considerable advance for this field. We introduce materials, device designs, wireless power delivery and communication strategies, and overall system architectures for skin-like, battery-free sensors of temperature and pressure that can be used across the entire body. Combined experimental and theoretical investigations of the sensor operation and the modes for wireless addressing define the key features of these systems. Studies with human subjects in clinical sleep laboratories and in adjustable hospital beds demonstrate functionality of the sensors, with potential implications for monitoring of circadian cycles and mitigating risks for pressure-induced skin ulcers.


Asunto(s)
Técnicas Biosensibles/métodos , Tecnología Inalámbrica , Diseño de Equipo , Humanos , Presión , Piel , Temperatura , Termografía
10.
ACS Nano ; 12(5): 4164-4171, 2018 05 22.
Artículo en Inglés | MEDLINE | ID: mdl-29641889

RESUMEN

Recently developed approaches in deterministic assembly allow for controlled, geometric transformation of two-dimensional structures into complex, engineered three-dimensional layouts. Attractive features include applicability to wide ranging layout designs and dimensions along with the capacity to integrate planar thin film materials and device layouts. The work reported here establishes further capabilities for directly embedding high-performance electronic devices into the resultant 3D constructs based on silicon nanomembranes (Si NMs) as the active materials in custom devices or microscale components released from commercial wafer sources. Systematic experimental studies and theoretical analysis illustrate the key ideas through varied 3D architectures, from interconnected bridges and coils to extended chiral structures, each of which embed n-channel Si NM MOSFETs (nMOS), Si NM diodes, and p-channel silicon MOSFETs (pMOS). Examples in stretchable/deformable systems highlight additional features of these platforms. These strategies are immediately applicable to other wide-ranging classes of materials and device technologies that can be rendered in two-dimensional layouts, from systems for energy storage, to photovoltaics, optoelectronics, and others.


Asunto(s)
Electrónica/instrumentación , Nanoestructuras/química , Silicio/química , Análisis de Elementos Finitos , Iluminación , Fenómenos Mecánicos , Metales/química , Óxidos/química , Dióxido de Silicio
11.
Sci Transl Med ; 8(366): 366ra165, 2016 11 23.
Artículo en Inglés | MEDLINE | ID: mdl-27881826

RESUMEN

Capabilities in health monitoring enabled by capture and quantitative chemical analysis of sweat could complement, or potentially obviate the need for, approaches based on sporadic assessment of blood samples. Established sweat monitoring technologies use simple fabric swatches and are limited to basic analysis in controlled laboratory or hospital settings. We present a collection of materials and device designs for soft, flexible, and stretchable microfluidic systems, including embodiments that integrate wireless communication electronics, which can intimately and robustly bond to the surface of the skin without chemical and mechanical irritation. This integration defines access points for a small set of sweat glands such that perspiration spontaneously initiates routing of sweat through a microfluidic network and set of reservoirs. Embedded chemical analyses respond in colorimetric fashion to markers such as chloride and hydronium ions, glucose, and lactate. Wireless interfaces to digital image capture hardware serve as a means for quantitation. Human studies demonstrated the functionality of this microfluidic device during fitness cycling in a controlled environment and during long-distance bicycle racing in arid, outdoor conditions. The results include quantitative values for sweat rate, total sweat loss, pH, and concentration of chloride and lactate.


Asunto(s)
Colorimetría/métodos , Microfluídica/instrumentación , Sudor/química , Dispositivos Electrónicos Vestibles , Adolescente , Adulto , Anciano , Técnicas Biosensibles , Niño , Cloruros/química , Diseño de Equipo , Femenino , Glucosa/química , Humanos , Concentración de Iones de Hidrógeno , Procesamiento de Imagen Asistido por Computador , Dispositivos Laboratorio en un Chip , Ácido Láctico/química , Masculino , Persona de Mediana Edad , Teléfono Inteligente , Interfaz Usuario-Computador , Adulto Joven
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA