Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 327
Filtrar
Más filtros

País/Región como asunto
Tipo del documento
Intervalo de año de publicación
1.
Folia Biol (Praha) ; 57(5): 182-90, 2011.
Artículo en Inglés | MEDLINE | ID: mdl-22123460

RESUMEN

The genetic basis for atherosclerosis development and progression is poorly characterized. We aimed to assess the relationship between endothelial nitric oxide synthase (ENOS) 894 G/T, haem oxygenase-1 (HO1) dinucleotide-length promoter polymorphisms and coronary artery atherosclerotic invol vement and its changes during statin therapy. Coronary angiography, intravascular ultrasound (IVUS), IVUS-derived virtual histology (VH) and genetic polymorphism analysis were performed at study entry. Patients were randomized 1:1 to standard or aggressive hypolipidaemic treatment, and a follow-up evaluation was performed after twelve months. Plaque magnitude was significantly higher in carriers of HO1 risk variants when compared with carriers of the protective variants (< 25 GT repeats). Similarly, the total coronary atherosclerotic burden was significantly greater in HO1 risk variant carriers than in HO1 protective variant carriers. Both parameters did not differ with respect to the ENOS genotype. A higher prevalence of thin-cap fibroatheroma (TCFA) in HO1 risk variant carriers was observed, compared with the HO1 protective variant carriers. The prevalence of TCFA was not influenced by the ENOS genotype. Baseline plaque composition did not differ significantly with respect to both polymorphisms. Significant interactions between plaque composition changes and ENOS and HO1 genotypes were observed during statin treatment. In conclusion, the protective HO1 promoter polymorphism correlates with a lower coronary artery plaque burden, whereas the protective ENOS 894 G/T polymorphism seems to favourably influence changes of coronary artery plaque composition during statin therapy, but has no significant correlation to the magnitude of coronary atherosclerosis.


Asunto(s)
Enfermedad de la Arteria Coronaria/enzimología , Vasos Coronarios/patología , Células Endoteliales/enzimología , Variación Genética , Hemo-Oxigenasa 1/genética , Óxido Nítrico Sintasa de Tipo III/genética , Anciano , Angiografía Coronaria , Enfermedad de la Arteria Coronaria/diagnóstico , Enfermedad de la Arteria Coronaria/tratamiento farmacológico , Enfermedad de la Arteria Coronaria/genética , Vasos Coronarios/diagnóstico por imagen , Femenino , Genotipo , Humanos , Inhibidores de Hidroximetilglutaril-CoA Reductasas/uso terapéutico , Masculino , Persona de Mediana Edad , Polimorfismo Genético , Ultrasonografía Intervencional
2.
J Inherit Metab Dis ; 31(6): 753-60, 2008 Dec.
Artículo en Inglés | MEDLINE | ID: mdl-18998239

RESUMEN

AIM: We used intravascular ultrasound (IVUS) to characterize coronary artery involvement in patients with Fabry disease (FD). METHODS: Nine FD patients (5 women) were matched to 10 control patients (5 women) chosen from our IVUS database. Standard volumetric IVUS analyses were performed along with assessment of plaque echodensity. RESULTS: Plaques in FD patients were diffuse and hypoechogenic compared with more focal and more echogenic lesions in control patients. Echogenicity of plaques was significantly lower in FD patients (median 30.7 +/- 12.9 vs 55.9 +/- 15.7, p = 0.0052, mean 37.2 +/- 15.6 vs 66.2 +/- 13.3, p = 0.0014). Diffusiveness was assessed as differences between mean and median plaque burden versus the plaque burden in each of the analysed cross-sections. These differences were lower in FD vs controls (5.8 +/- 4.8 vs 8.7 +/- 6.6, p < 0.001 for mean, and 5.8 +/- 4.9 vs 8.8 +/- 7.3, p < 0.001 for median) indicating a more diffuse involvement. The occurrence of lipid cores was significantly higher in FD patients than in controls (2.4 +/- 1.5 vs 1.0 +/- 0.94, p = 0.02). CONCLUSION: IVUS showed diffuse hypoechogenic plaques in patients with FD. The explanation may be higher lipid content in plaques and accumulation of glycosphingolipid in smooth-muscle and endothelial cells.


Asunto(s)
Enfermedad de la Arteria Coronaria/diagnóstico por imagen , Enfermedad de la Arteria Coronaria/diagnóstico , Vasos Coronarios/diagnóstico por imagen , Vasos Coronarios/patología , Enfermedad de Fabry/diagnóstico por imagen , Enfermedad de Fabry/diagnóstico , Anciano , Estudios de Casos y Controles , Angiografía Coronaria/métodos , Enfermedad de la Arteria Coronaria/complicaciones , Endotelio Vascular/patología , Enfermedad de Fabry/complicaciones , Femenino , Fibroblastos/metabolismo , Humanos , Masculino , Persona de Mediana Edad , Trihexosilceramidas/metabolismo , Ultrasonografía
3.
Circulation ; 102(1): 7-10, 2000 Jul 04.
Artículo en Inglés | MEDLINE | ID: mdl-10880407

RESUMEN

BACKGROUND: Intravascular ultrasound analysis has assessed mechanisms of lumen enlargement after nonstent interventions, but not after stenting. METHODS AND RESULTS: Preintervention and postintervention intravascular ultrasound was used to study 25 de novo native coronary lesions treated with single MultiLink stents without preatheroablation. External elastic membrane, lumen, and plaque and media (P&M) areas were measured every 1 mm to include the lesion and reference segments that were 5 mm proximal and distal to it. Lesion mean lumen area increased from 4.0+/-1.0 mm(2) before the intervention to 8.8+/-2.0 mm(2) after the intervention (P<0.0001) as a result of an increase in mean external elastic membrane area (14. 2+/-2.7 to 16.1+/-3.0 mm(2), P<0.0001) and a decrease in mean P&M area (10.2+/-2.2 to 7.2+/-1.8 mm(2), P<0.0001). The decrease in lesion P&M was accompanied by an increase in both proximal reference mean P&M (7.0+/-1.9 to 8.4+/-2.0 mm(2), P<0.0001) and distal reference mean P&M (5.8+/-2.1 to 7.2+/-2.1 mm(2), P<0.0001). Volumetric analysis showed an axial redistribution of plaque away from the center of the lesion toward the reference segments to increase the plaque burden in both the proximal and distal reference segments. Total (lesion plus reference) mean P&M decreased from 8. 6+/-2.1 to 7.5+/-1.8 mm(2) (P<0.0001). CONCLUSIONS: The mechanisms of lumen enlargement after stenting involved (1) significant axial redistribution of plaque from the lesion into the reference segments, (2) vessel expansion, and (3) either plaque embolization or compression.


Asunto(s)
Enfermedad Coronaria/diagnóstico por imagen , Enfermedad Coronaria/terapia , Revascularización Miocárdica/métodos , Complicaciones Posoperatorias/diagnóstico por imagen , Stents , Anciano , Estudios de Cohortes , Angiografía Coronaria , Circulación Coronaria , Elasticidad , Femenino , Humanos , Masculino , Persona de Mediana Edad , Revascularización Miocárdica/instrumentación , Ultrasonografía
4.
Circulation ; 101(19): 2227-30, 2000 May 16.
Artículo en Inglés | MEDLINE | ID: mdl-10811587

RESUMEN

BACKGROUND: The effects of endovascular irradiation on uninjured reference segments during the treatment of in-stent restenosis are unknown. METHODS AND RESULTS: In the Washington Radiation for In-Stent restenosis Trial (WRIST), patients with in-stent restenosis were first treated with conventional catheter-based techniques and then randomized (blinded) to receive either gamma-irradiation ((192)Ir) or a placebo (dummy seeds). We identified all patients in whom the active (n=19) or dummy seeds (n=19) extended >10 mm proximal and distal to the in-stent restenosis lesion. Serial (postirradiation and follow-up) external elastic membrane (EEM), lumen, and plaque and media (EEM-lumen) areas were measured (using intravascular ultrasound) every 1 mm over 5-mm-long reference segments that were 6 to 10 mm proximal and distal to the in-stent restenosis lesion. During follow-up, a similar small increase occurred in the plaque and media area in the proximal and distal reference segments in both (192)Ir and placebo patients. However, in the (192)Ir patients, an increase in both proximal and distal EEM area occurred; as a result, no change in lumen area occurred. Conversely, in the placebo patients, the proximal reference EEM area decreased, and no change occurred in the distal reference EEM area; this contributed to a decrease in lumen area. CONCLUSIONS: There was no evidence of a deleterious effect of gamma-irradiation on angiographically normal uninjured reference segments in the first 6 months after the treatment of in-stent restenosis.


Asunto(s)
Enfermedad Coronaria/radioterapia , Vasos Coronarios/efectos de la radiación , Stents , Enfermedad Coronaria/diagnóstico por imagen , Vasos Coronarios/diagnóstico por imagen , Método Doble Ciego , Tejido Elástico/diagnóstico por imagen , Tejido Elástico/efectos de la radiación , Humanos , Recurrencia , Factores de Tiempo , Resultado del Tratamiento , Ultrasonografía Intervencional
5.
Circulation ; 101(6): 604-10, 2000 Feb 15.
Artículo en Inglés | MEDLINE | ID: mdl-10673251

RESUMEN

BACKGROUND: Elevation of serum creatine kinase MB fraction (CK-MB) after percutaneous coronary interventions has been associated with early and late mortality; however, the pathogenesis of CK-MB elevation is still unknown. We hypothesized that CK-MB elevation was related to atherosclerotic plaque burden as assessed by preintervention intravascular ultrasound (IVUS). METHODS AND RESULTS: We studied 2256 consecutive patients who underwent intervention of 2780 native coronary lesions and had complete high-quality preintervention IVUS imaging in the era before routine use of platelet glycoprotein IIb/IIIa inhibitors. Patients were divided into 3 groups: CK-MB within normal range (1675 patients; 2061 lesions); CK-MB elevation 1 to 5 times upper limit of normal (292 patients; 355 lesions); and CK-MB elevation > or = 5 times upper limit of normal (289 patients; 364 lesions). Qualitative angiographic lesion morphology and quantitative analysis were similar among the 3 groups. On preintervention IVUS, progressively more reference segment and lesion site plaque burden and lesion site calcium occurred in the groups with CK-MB elevation. Positive remodeling was more common in lesions with CK-MB elevation. As levels of CK-MB increased, cross-sectional narrowing (percentage plaque burden) increased, both at the reference site (mean cross-sectional narrowing values were 45.1%, <49.3%, and <52.2% for normal CK-MB, 1 to 5 times upper limit of normal, and > or =5 times upper limit of normal groups, respectively; P=0.03) and at the lesion site (81.9%, <85.4%, and <87.1%, respectively; P=0.04). Multivariate analysis indicated that de novo lesions, atheroablative technique, plaque burden at the lesion and reference segments, and final minimal lumen diameter were independent predictors of CK-MB elevation. CONCLUSIONS: CK-MB elevation correlates with a greater atherosclerotic plaque burden. CK-MB elevation after intervention may be a marker of diffuse atherosclerotic disease or a consequence of catheter-based intervention in more diseased arteries or both.


Asunto(s)
Angioplastia de Balón , Enfermedad de la Arteria Coronaria , Creatina Quinasa/sangre , Anciano , Enfermedad de la Arteria Coronaria/sangre , Enfermedad de la Arteria Coronaria/diagnóstico por imagen , Enfermedad de la Arteria Coronaria/patología , Enfermedad de la Arteria Coronaria/cirugía , Femenino , Humanos , Isoenzimas , Masculino , Persona de Mediana Edad , Ultrasonografía Intervencional
6.
Circulation ; 99(24): 3149-54, 1999 Jun 22.
Artículo en Inglés | MEDLINE | ID: mdl-10377078

RESUMEN

BACKGROUND: Pathological and intravascular ultrasound (IVUS) studies have documented arterial remodeling during atherogenesis. However, the impact of this remodeling process on the long-term outcome after percutaneous intervention is unknown. METHODS AND RESULTS: We used preintervention IVUS to define positive and negative/intermediate remodeling in a total of 777 lesions in 715 patients treated with nonstent techniques. Positive remodeling (lesion external elastic membrane area greater than average reference) was present in 313 lesions; intermediate/negative remodeling (lesion external elastic membrane area less than or equal to reference) was present in the other 464. Baseline clinical and angiographic characteristics were similar, except for a slightly higher percentage of insulin-dependent diabetic patients (10.2% versus 6.1%; P=0.054) in the negative/intermediate-remodeling group. Angiographic success and in-hospital and short-term complications were comparable in the 2 groups. There was no significant correlation between remodeling (as a continuous variable) and final lumen area (r=0.06) or final lesion plaque burden (r=0.17). At 18+/-13 months of clinical follow-up, both groups had similar rates of death and Q-wave myocardial infarction: 3.4% and 2.5% for the negative/intermediate-remodeling group versus 2.7% and 2.7% for the positive-remodeling group. However, the target-lesion revascularization (TLR) rate was 20.2% for the negative/intermediate-remodeling group versus 31.2% for the positive-remodeling group (P=0.007), and remodeling, as a continuous variable, was strongly correlated with probability of TLR (P=0.0001). By multivariable logistic regression analysis, diabetes (OR=2.3), left anterior descending artery location (OR=1.8), and remodeling (OR=5.9) were independent predictors of TLR. CONCLUSIONS: Positive lesion-site remodeling is associated with a higher long-term TLR after a nonstent interventional procedure. Thus, long-term clinical outcome appears to be determined in part by preintervention lesion characteristics.


Asunto(s)
Angioplastia de Balón , Enfermedad Coronaria/diagnóstico por imagen , Enfermedad Coronaria/cirugía , Ultrasonografía Intervencional , Anciano , Angiografía Coronaria , Enfermedad Coronaria/terapia , Ecocardiografía , Femenino , Estudios de Seguimiento , Humanos , Masculino , Persona de Mediana Edad , Análisis Multivariante , Complicaciones Posoperatorias , Stents , Resultado del Tratamiento
7.
Circulation ; 104(8): 856-9, 2001 Aug 21.
Artículo en Inglés | MEDLINE | ID: mdl-11514368

RESUMEN

BACKGROUND: The efficacy of coronary gamma-irradiation in preventing recurrent in-stent restenosis (ISR) is well established. However, brachytherapy may be less effective in very long, diffuse ISR lesions. METHODS AND RESULTS: We used serial intravascular ultrasound (IVUS) to study patients with long, diffuse ISR lesions (length, 36 to 80 mm) who were enrolled in (1) Long WRIST (Washington Radiation In-Stent Restenosis Trial), a double-blind, placebo-controlled trial of intracoronary gamma-irradiation (15 Gy at 2 mm from the source) and (2) high-dose (HD) Long WRIST, a registry that used a dose prescription of 18 Gy at 2 mm from the source. IVUS was performed using automated pullback (0.5 mm/s). Stent, lumen, and intimal hyperplasia were measured at 2-mm intervals. Complete postintervention and follow-up IVUS imaging was available in 30 irradiated and 34 placebo patients from Long WRIST and in 25 patients from HD Long WRIST. Stent length was longer in HD Long WRIST than in placebo or treated patients in Long WRIST (P=0.0064 and P=0.0125, respectively). Otherwise, baseline measurements were similar. At follow-up, the minimum lumen area was largest in the HD Long WRIST patients (4.0+/-1.4 mm(2)); areas were 2.9+/-1.0 mm(2) in irradiated patients in Long WRIST and 1.9+/-1.1 mm(2) in placebo patients in Long WRIST (P<0.005 for all comparisons). CONCLUSIONS: - Serial IVUS analysis shows that gamma-irradiation reduces recurrent in-stent neointimal hyperplasia in long, diffuse ISR lesions; however, it is even more effective when given at a higher dose.


Asunto(s)
Rayos gamma/uso terapéutico , Oclusión de Injerto Vascular/prevención & control , Revascularización Miocárdica , Stents , Ultrasonografía Intervencional , Braquiterapia/métodos , Enfermedad Coronaria/cirugía , Relación Dosis-Respuesta en la Radiación , Método Doble Ciego , Oclusión de Injerto Vascular/clasificación , Oclusión de Injerto Vascular/diagnóstico , Humanos , Persona de Mediana Edad , Revascularización Miocárdica/efectos adversos , Revascularización Miocárdica/métodos , Factores de Riesgo , Prevención Secundaria , Stents/efectos adversos , Resultado del Tratamiento , Grado de Desobstrucción Vascular/efectos de la radiación
8.
Circulation ; 101(21): 2484-9, 2000 May 30.
Artículo en Inglés | MEDLINE | ID: mdl-10831522

RESUMEN

BACKGROUND: Atheroablation yields improved clinical results for balloon angioplasty (percutaneous transluminal coronary angioplasty, PTCA) in the treatment of diffuse in-stent restenosis (ISR). METHODS AND RESULTS: We compared the mechanisms and clinical results of excimer laser coronary angioplasty (ELCA) versus rotational atherectomy (RA), both followed by adjunct PTCA; 119 patients (158 ISR lesions) were treated with ELCA+PTCA and 130 patients (161 ISR lesions) were treated with RA+PTCA. Quantitative coronary angiographic and planar intravascular ultrasound (IVUS) measurements were performed routinely. In addition, volumetric IVUS analysis to compare the mechanisms of lumen enlargement was performed in 28 patients with 30 lesions (16 ELCA+PTCA, 14 RA+PTCA). There were no significant between-group differences in preintervention or final postintervention quantitative coronary angiographic or planar IVUS measurements of luminal dimensions. Angiographic success and major in-hospital complications with the 2 techniques were also similar. Volumetric IVUS analysis showed significantly greater reduction in intimal hyperplasia volume after RA than after ELCA (43+/-14 versus 19+/-10 mm(3), P<0.001) because of a significantly higher ablation efficiency (90+/-10% versus 76+/-12%, P = 0.004). However, both interventional strategies had similar long-term clinical outcome; 1-year target lesion revascularization rate was 26% with ELCA+PTCA versus 28% with RA+PTCA (P = NS). CONCLUSIONS: Despite certain differences in the mechanisms of lumen enlargement, both ELCA+PTCA and RA+PTCA can be used to treat diffuse ISR with similar clinical results.


Asunto(s)
Angioplastia de Balón Asistida por Láser , Aterectomía Coronaria/métodos , Enfermedad Coronaria/terapia , Stents , Angioplastia Coronaria con Balón , Angiografía Coronaria , Enfermedad Coronaria/prevención & control , Femenino , Estudios de Seguimiento , Humanos , Masculino , Persona de Mediana Edad , Recurrencia , Resultado del Tratamiento , Ultrasonografía Intervencional
9.
Circulation ; 101(16): 1895-8, 2000 Apr 25.
Artículo en Inglés | MEDLINE | ID: mdl-10779453

RESUMEN

BACKGROUND: Intracoronary gamma-radiation therapy reduces recurrent in-stent restenosis (ISR). This study, BETA WRIST (Washington Radiation for In-Stent restenosis Trial) was designed to examine the efficacy and safety of the beta-emitter 90-yttrium for the prevention of recurrent ISR. METHODS AND RESULTS: A total of 50 consecutive patients with ISR in native coronaries underwent percutaneous transluminal coronary angioplasty, laser angioplasty, rotational atherectomy, and/or stent implantation. Afterward, a segmented balloon catheter was positioned and automatically loaded with a 90-yttrium, 0.014-inch source wire that was 29 mm in length to deliver a dose of 20.6 Gy at 1.0 mm from the balloon surface. In 17 patients, manual stepping of the radiation catheter was necessary for lesions >25 mm in length. The radiation was delivered successfully to all patients, with a mean dwell time of 3.0+/-0.4 minutes. Fractionation of the dose due to ischemia was required in 11 patients. At 6 months, the binary angiographic restenosis rate was 22%, the target lesion revascularization rate was 26%, and the target vessel revascularization rate was 34%; all rates were significantly lower than those of the placebo group of gamma-WRIST. CONCLUSIONS: beta-Radiation with a 90-yttrium source used as adjunct therapy for patients with ISR results in a lower-than-expected rate of angiographic and clinical restenosis.


Asunto(s)
Angioplastia Coronaria con Balón , Braquiterapia , Enfermedad Coronaria/radioterapia , Stents , Adulto , Anciano , Partículas beta , Constricción Patológica , Enfermedad Coronaria/patología , Vasos Coronarios/patología , Femenino , Estudios de Seguimiento , Humanos , Masculino , Estudios Prospectivos , Recurrencia , Túnica Íntima/patología , Radioisótopos de Itrio/uso terapéutico
10.
Circulation ; 100(3): 256-61, 1999 Jul 20.
Artículo en Inglés | MEDLINE | ID: mdl-10411849

RESUMEN

BACKGROUND: Angiography is limited in determining the anatomic severity of coronary artery stenoses. Clinical decision-making in patients with symptoms and intermediate lesions remains challenging. METHODS AND RESULTS: The current analysis included 300 patients (357 intermediate native artery lesions) in whom intervention was deferred based on intravascular ultrasound (IVUS) findings. Standard clinical, angiographic, and IVUS parameters were collected. Patients were followed for >1 year. Events occurred in 24 patients (8%). They included 2 cardiac deaths, 4 myocardial infarctions, and 18 target-lesion revascularizations (TLR; 12 percutaneous transluminal coronary angiographies and 6 coronary artery bypass grafts; only 3 TLRs occurred within 6 months after the IVUS study). All significant univariate clinical, angiographic, and IVUS parameters (P<0.05) were tested in multivariate models. These included diabetes mellitus, IVUS lesion lumen area, maximum lumen diameter, minimum lumen diameter, plaque area, plaque burden, and area stenosis (AS). No angiographic measurement was significant at P<0.05. The only independent predictors of an event (death, myocardial infarction, or TLR) were IVUS minimum lumen area and AS. The only independent predictors of TLR were diabetes mellitus, IVUS minimum lumen area, and AS. In 248 lesions with a minimum lumen area >/=4.0 mm(2), the event rate was only 4.4% and the TLR rate 2.8%. CONCLUSIONS: Long-term follow-up after IVUS-guided deferred interventions in patients with de novo intermediate native artery lesions showed a low event rate. In patients with a minimum lumen area >/=4.0 mm(2), the event rate was especially low. IVUS imaging is an acceptable alternative to physiological assessment in these patients.


Asunto(s)
Angioplastia Coronaria con Balón , Vasos Coronarios/patología , Ultrasonografía/métodos , Angiografía Coronaria , Enfermedad Coronaria/diagnóstico , Enfermedad Coronaria/prevención & control , Vasos Coronarios/diagnóstico por imagen , Femenino , Estudios de Seguimiento , Humanos , Masculino , Persona de Mediana Edad , Análisis Multivariante , Factores de Riesgo , Factores de Tiempo
11.
Circulation ; 100(24): 2400-5, 1999 Dec 14.
Artículo en Inglés | MEDLINE | ID: mdl-10595951

RESUMEN

BACKGROUND: Although the risk for development of creatine kinase (CK-MB) elevation after saphenous vein graft (SVG) intervention is high, its prognostic significance remains unknown. This study evaluated the impact of periprocedural CK-MB elevation on late clinical events following successful SVG angioplasty. METHODS AND RESULTS: We studied 1056 consecutive patients with successful (defined by angiographic success and absence of major complications) intervention of 1693 SVG lesions. These patients were grouped as normal CK-MB (n=556), minor CK-MB rise (CK-MB 1 to 5 times normal, n=339), and major CK-MB rise (CK-MB >5 times normal, n=161). There were no differences in major clinical events at 30-day follow-up among the 3 groups. However, 1-year mortality was 4.8%, 6.5%, and 11. 7%, respectively, P<0.05 (ANOVA). Even within a population without any intraprocedure or in-hospital complications (n=727, 69% of the overall cohort), 1-year mortality remained significantly higher with CK-MB elevation: 2.4%, 5.5%, and 10.7%, respectively, P<0.05 (ANOVA). Multivariate analysis revealed major CK-MB elevation as the strongest independent predictor of late mortality (odds ratio 3.3, with 95% CI 1.7 to 6.2), followed by diabetes mellitus (odds ratio 2. 6, with 95% CI 1.5 to 4.5). CONCLUSIONS: Major CK-MB elevation occurs after 15% of otherwise successful SVG interventions and is associated with increased late mortality.


Asunto(s)
Enfermedad Coronaria , Creatina Quinasa/metabolismo , Vena Safena/trasplante , Anciano , Causas de Muerte , Angiografía Coronaria , Enfermedad Coronaria/enzimología , Enfermedad Coronaria/mortalidad , Enfermedad Coronaria/cirugía , Femenino , Humanos , Pacientes Internos/estadística & datos numéricos , Isoenzimas , Masculino , Persona de Mediana Edad , Análisis Multivariante , Infarto del Miocardio/enzimología , Infarto del Miocardio/mortalidad , Infarto del Miocardio/cirugía , Valor Predictivo de las Pruebas , Stents , Resultado del Tratamiento
12.
Circulation ; 100(18): 1872-8, 1999 Nov 02.
Artículo en Inglés | MEDLINE | ID: mdl-10545431

RESUMEN

BACKGROUND: The angiographic presentation of in-stent restenosis (ISR) may convey prognostic information on subsequent target vessel revascularizations (TLR). METHODS AND RESULTS: We developed an angiographic classification of ISR according to the geographic distribution of intimal hyperplasia in reference to the implanted stent. Pattern I includes focal (< or =10 mm in length) lesions, pattern II is ISR>10 mm within the stent, pattern III includes ISR>10 mm extending outside the stent, and pattern IV is totally occluded ISR. We classified a total of 288 ISR lesions in 245 patients and verified the angiographic accuracy of the classification by intravascular ultrasound. Pattern I was found in 42% of patients, pattern II in 21%, pattern III in 30%, and pattern IV in 7%. Previously recurrent ISR was more frequent with increasing grades of classification (9%, 20%, 34%, and 50% for classes I to IV, respectively; P=0.0001), as was diabetes (28%, 32%, 39%, and 48% in classes I to IV, respectively; P<0.01). Angioplasty and stenting were used predominantly in classes I and II, whereas classes III and IV were treated with atheroablation. Final diameter stenosis ranged between 21% and 28% (P=NS among ISR patterns). TLR increased with increasing ISR class; it was 19%, 35%, 50%, and 83% in classes I to IV, respectively (P<0.001). Multivariate analysis showed that diabetes (odds ratio, 2.8), previously recurrent ISR (odds ratio, 2. 7), and ISR class (odds ratio, 1.7) were independent predictors of TLR. CONCLUSIONS: The introduced angiographic classification is prognostically important, and it may be used for appropriate and early patient triage for clinical and investigational purposes.


Asunto(s)
Angiografía Coronaria , Enfermedad Coronaria/terapia , Stents , Angioplastia Coronaria con Balón , Enfermedad Coronaria/diagnóstico , Femenino , Humanos , Masculino , Persona de Mediana Edad , Análisis Multivariante , Pronóstico , Recurrencia , Estudios Retrospectivos , Resultado del Tratamiento , Ultrasonografía Intervencional
13.
Circulation ; 103(19): 2332-5, 2001 May 15.
Artículo en Inglés | MEDLINE | ID: mdl-11352879

RESUMEN

BACKGROUND: Intracoronary gamma-radiation reduces recurrent in-stent restenosis. Late thrombosis (>30 days after radiation therapy) is identified as a serious complication. The Washington Radiation for In-Stent Restenosis Trial (WRIST) PLUS, which involved 6 months of treatment with clopidogrel and aspirin, was designed to examine the efficacy and safety of prolonged antiplatelet therapy for the prevention of late thrombosis. METHODS AND RESULTS: A total of 120 consecutive patients with diffuse in-stent restenosis in native coronary arteries and vein grafts with lesions <80 mm underwent percutaneous coronary transluminal angioplasty, laser ablation, and/or rotational atherectomy. Additional stents were placed in 34 patients (28.3%). After the intervention, a closed-end lumen catheter was introduced into the artery, a ribbon with different trains of radioactive (192)Ir seeds was positioned to cover the treated site, and a dose of 14 Gy to 2 mm was prescribed. Patients were discharged with clopidogrel and aspirin for 6 months and followed angiographically and clinically. All patients but one tolerated the clopidogrel. The late occlusion and thrombosis rates were compared with the gamma-radiation-treated (n=125) and the placebo patients (n=126) from the WRIST and LONG WRIST studies (which involved only 1 month of antiplatelet therapy). At 6 months, the group receiving prolonged antiplatelet therapy had total occlusion and late thrombosis rates of 5.8% and 2.5%, respectively; these rates were lower than those in the active gamma-radiation group and similar to those in the placebo historical control group. CONCLUSIONS: Six months of clopidogrel and aspirin and a reduction in re-stenting for patients with in-stent restenosis treated with gamma-radiation is well tolerated and associated with a reduction in the late thrombosis rate compared with a similar cohort treated with only 1 month of clopidogrel and aspirin.


Asunto(s)
Enfermedad Coronaria/terapia , Inhibidores de Agregación Plaquetaria/uso terapéutico , Trombosis/prevención & control , Ticlopidina/análogos & derivados , Ticlopidina/uso terapéutico , Anciano , Clopidogrel , Angiografía Coronaria , Femenino , Estudios de Seguimiento , Rayos gamma/efectos adversos , Rayos gamma/uso terapéutico , Humanos , Masculino , Persona de Mediana Edad , Stents/efectos adversos , Trombosis/etiología , Factores de Tiempo , Resultado del Tratamiento
14.
Circulation ; 104(25): 3020-2, 2001 Dec 18.
Artículo en Inglés | MEDLINE | ID: mdl-11748092

RESUMEN

BACKGROUND: We used serial volumetric (post-irradiation and follow-up) intravascular ultrasound (IVUS) to compare the effectiveness of gamma-irradiation ((192)Ir) in saphenous vein graft (SVG) versus native coronary artery in-stent restenosis (ISR). METHODS AND RESULTS: The study population consisted of 47 patients with native coronary artery ISR from WRIST (Washington Radiation for In-Stent Restenosis Trial) and 31 patients with SVG ISR (12 from the WRIST and 19 from SVGWRIST). After irradiation and at 6-month follow-up, stent, lumen, and intimal hyperplasia (IH, stent minus lumen) areas were measured every 1 mm. ISR length was similar in the 2 groups (29+/-12 versus 29+/-14 mm, P=0.9). Post-intervention measurements of stent (280+/-154 versus 324+/-270 mm(3), P=0.4), lumen (184+/-91 versus 214+/-172 mm(3), P=0.3), and IH (96+/-77 versus 109+/-119 mm(3), P=0.5) volumes were similar in the 2 groups. The post-intervention minimum lumen cross sectional areas tended to be smaller in native artery ISR lesions (4.7+/-1.7 versus 5.4+/-1.6 mm(2), P=0.11). During follow-up, there was a slight increase in IH volume (9+/-38 mm(3)) in native artery ISR lesions and a slight decrease in IH volume in SVG ISR lesions (-9+/-32 mm(3), P=0.0463). There was also a slight decrease in minimum lumen area in the native artery ISR lesions versus a slight increase in minimum lumen area in the SVG ISR lesions (-0.8+/-1.7 versus 0.2+/-1.1, P=0.0087). As a result, the follow-up minimum lumen area in native artery lesions was smaller than in SVG ISR lesions (4.1+/-2.1 mm(2) versus 5.6+/-2.2 mm(2), P=0.0067). CONCLUSION: gamma-Irradiation with (192)Ir brachytherapy appears to be as effective in SVGs as it is in native artery ISR lesions.


Asunto(s)
Enfermedad Coronaria/radioterapia , Vasos Coronarios/efectos de la radiación , Rayos gamma/uso terapéutico , Vena Safena/trasplante , Stents , Anciano , Angiografía Coronaria , Enfermedad Coronaria/diagnóstico por imagen , Enfermedad Coronaria/terapia , Vasos Coronarios/diagnóstico por imagen , Vasos Coronarios/patología , Femenino , Estudios de Seguimiento , Humanos , Masculino , Persona de Mediana Edad , Dosificación Radioterapéutica , Resultado del Tratamiento , Ultrasonografía Intervencional
15.
Circulation ; 102(24): 2915-8, 2000 Dec 12.
Artículo en Inglés | MEDLINE | ID: mdl-11113039

RESUMEN

BACKGROUND: The aim of this study was to use serial volumetric intravascular ultrasound to evaluate the effect of gamma-radiation on recurrent in-stent restenosis. METHODS AND RESULTS: After successful reintervention, patients were randomized to receive either (192)Ir or placebo. Intravascular ultrasound studies with motorized pullback (0.5 mm/s) were performed immediately after irradiation and at 8-month follow-up in 70 patients. Paired volumetric analysis of the stented segment and of 5-mm proximal and distal reference segments was performed; this included measurements of the external elastic membrane, lumen, plaque and media (external elastic membrane minus lumen), stent, and intimal hyperplasia (stent minus lumen). Baseline proximal reference, stent, and distal reference measurements were similar in both groups. The changes in proximal and distal reference measurements of the external elastic membrane, plaque and media, and lumen areas were similar in both groups. However, the decrease in stented segment lumen volume was less in the (192)Ir patients than the placebo patients (-25+/-34 mm(3) versus -48+/-42 mm(3); P:=0.0225), and the increase in the volume of intimal hyperplasia in the stented segment was less in the (192)Ir patients than in the placebo patients (28+/-37 mm(3) versus 50+/-40 mm(3); P:=0.0352). When averaged over the length of the stented segment (32+/-13 mm versus 33+/-14 mm; P:=0.9), the increase in mean area of intimal hyperplasia was 0.8+/-1.0 mm(2) in the (192)Ir group and 1.6+/-1.2 mm(2) in the control group (P:=0.0065). Late stent-vessel wall malapposition was noted in one placebo patient and no (192)Ir patients. CONCLUSIONS: gamma-Radiation therapy can effectively prevent recurrent in-stent restenosis by inhibiting neointimal formation within the stent. At the stent edge, there were no significant differences between (192)Ir and placebo patients.


Asunto(s)
Enfermedad Coronaria/terapia , Rayos gamma , Falla de Prótesis , Stents , Análisis de Varianza , Enfermedad Coronaria/etiología , Vasos Coronarios/patología , Vasos Coronarios/efectos de la radiación , Estudios de Seguimiento , Humanos , Hiperplasia/prevención & control , Iridio
16.
Circulation ; 101(18): 2165-71, 2000 May 09.
Artículo en Inglés | MEDLINE | ID: mdl-10801757

RESUMEN

BACKGROUND: Treatment of in-stent restenosis presents a critical limitation of intracoronary stent implantation. Ionizing radiation has been shown to decrease neointimal formation within stents in animal models and in initial clinical trials. We studied the effects of intracoronary gamma-radiation therapy versus placebo on the clinical and angiographic outcomes of patients with in-stent restenosis. METHODS AND RESULTS: One hundred thirty patients with in-stent restenosis underwent successful coronary intervention and were then blindly randomized to receive either intracoronary gamma-radiation with (192)Ir (15 Gy) or placebo. Four independent core laboratories blinded to the treatment protocol analyzed the angiographic and intravascular ultrasound end points of restenosis. Procedural success and in-hospital and 30-day complications were similar among the groups. At 6 months, patients assigned to radiation therapy required less target lesion revascularization and target vessel revascularization (9 [13.8%] and 17 [26.2%], respectively) compared with patients assigned to placebo (41 [63.1%, P=0.0001] and 44 [67.7%, P=0.0001], respectively). Binary angiographic restenosis was lower in the irradiated group (19% versus 58% for placebo, P=0.001). Freedom from major cardiac events was lower in the radiation group (29.2% versus 67.7% for placebo, P<0.001). CONCLUSIONS: Intracoronary gamma-radiation used as adjunct therapy for patients with in-stent restenosis significantly reduces both angiographic and clinical restenosis.


Asunto(s)
Enfermedad Coronaria/radioterapia , Rayos gamma/uso terapéutico , Stents , Anciano , Angioplastia de Balón , Enfermedad Coronaria/fisiopatología , Enfermedad Coronaria/cirugía , Método Doble Ciego , Femenino , Humanos , Masculino , Persona de Mediana Edad , Recurrencia , Resultado del Tratamiento
17.
J Am Coll Cardiol ; 8(2): 317-26, 1986 Aug.
Artículo en Inglés | MEDLINE | ID: mdl-2942593

RESUMEN

Doppler echocardiography was performed in 136 patients with a normally functioning prosthetic valve in the aortic (n = 59), mitral (n = 74) and tricuspid (n = 3) positions. These included patients with St. Jude (n = 82), Björk-Shiley (n = 18), Beall (n = 13), Starr-Edwards (n = 7) or tissue (n = 16) valves. Peak and mean pressure gradients across the prostheses were measured using the simplified Bernoulli equation. The prosthetic valve orifice (PVO, in square centimeters), only in the mitral position, was calculated by the equation: PVO = 220/pressure half-time. In the aortic position, the St. Jude valve had a lower peak velocity (2.3 +/- 0.6 m/s, range 1.0 to 3.9), peak gradient (22 +/- 12 mm Hg, range 4 to 61) and mean gradient (12 +/- 7 mm Hg, range 2 to 32) than the other valves (p less than 0.05) when compared with Starr-Edwards). In the mitral position, the St. Jude valve had the largest orifice (3.0 +/- 0.6 cm2, range 1.8 to 5.0) (p less than 0.0001 compared with all other valves). Insignificant regurgitation was commonly found by pulsed mode Doppler technique in patients with a St. Jude or Björk-Shiley valve in the aortic or mitral position and in patients with a Starr-Edwards or tissue valve in the aortic position. In 17 other patients with a malfunctioning prosthesis (four St. Jude, two Björk-Shiley, four Beall and seven tissue valves) proven by cardiac catheterization, surgery or autopsy, Doppler echocardiography correctly identified the complication (significant regurgitation or obstruction) in all but 2 patients who had a Beall valve. It is concluded that 1) the St. Jude valve appears to have the most optimal hemodynamics; mild regurgitation can be detected by the Doppler technique in normally functioning St. Jude and Björk-Shiley valves in the aortic or mitral position and in Starr-Edwards and tissue valves in the aortic position, and 2) Doppler echocardiography is a useful method for the detection of prosthetic valve malfunction, especially when the St. Jude, Björk-Shiley and tissue valves are assessed.


Asunto(s)
Enfermedades de las Válvulas Cardíacas/terapia , Prótesis Valvulares Cardíacas/normas , Adolescente , Adulto , Anciano , Bioprótesis/normas , Velocidad del Flujo Sanguíneo , Presión Sanguínea , Ecocardiografía , Femenino , Enfermedades de las Válvulas Cardíacas/diagnóstico , Humanos , Masculino , Persona de Mediana Edad , Reología
18.
J Am Coll Cardiol ; 15(2): 373-7, 1990 Feb.
Artículo en Inglés | MEDLINE | ID: mdl-2299079

RESUMEN

High frequency (7.5 MHz) two-dimensional ultrasound in combination with modified acoustic windows allowed visualization of the distal left anterior descending artery in 61 (85%) of 72 patients studied. Visualization was confirmed in one patient who underwent simultaneous high frequency ultrasound recording and selective dye injection into the left coronary artery. In addition, calcific coronary atherosclerosis was identified in one patient. The saphenous vein bypass graft along with its distal site of anastomosis was clearly seen in 3 patients and coronary artery flow was detected in 24 (33%).


Asunto(s)
Vasos Coronarios/patología , Ecocardiografía Doppler/métodos , Adulto , Anciano , Anciano de 80 o más Años , Enfermedades Cardiovasculares/diagnóstico , Enfermedades Cardiovasculares/fisiopatología , Enfermedades Cardiovasculares/cirugía , Puente de Arteria Coronaria , Enfermedad de la Arteria Coronaria/diagnóstico , Vasos Coronarios/fisiopatología , Femenino , Humanos , Masculino , Persona de Mediana Edad , Flujo Sanguíneo Regional , Tórax
19.
J Am Coll Cardiol ; 7(4): 768-74, 1986 Apr.
Artículo en Inglés | MEDLINE | ID: mdl-3958334

RESUMEN

M-mode and Doppler echocardiography were performed in 16 patients with first degree atrioventricular (AV) block, 1 patient with second degree (Wenckebach type) and 3 patients with third degree AV block; 20 individuals with a normal PR interval served as control subjects. The time from the onset of the P wave to the mitral valve closure by M-mode and to the end of mitral flow by Doppler echocardiography were obtained. In 20 normal subjects, the P wave to mitral valve closure interval measured 220 +/- 30 ms by M-mode and to the end of mitral flow 225 +/- 29 ms by Doppler technique (p = NS). In patients with first degree AV block, these intervals measured 242 +/- 41 and 249 +/- 36 ms, respectively (p = NS). Late diastolic (before the onset of the QRS complex) mitral regurgitation was detected by pulsed mode Doppler imaging in 9 (56%) of the 16 patients with first degree AV block but in none with a normal PR interval. In the four patients with advanced AV block, intermittent mid or late diastolic mitral regurgitation was found to depend on the position of the P wave in diastole. With early diastolic P waves, the end of mitral valve flow by Doppler technique occurred 230 to 250 ms after the onset of the P wave and was followed by mild diastolic mitral regurgitation of variable duration. With P waves falling in systole, the mitral valve remained open throughout diastole; during most of diastole, however, there was neither forward mitral flow (diastasis) nor diastolic mitral regurgitation detected by Doppler technique.(ABSTRACT TRUNCATED AT 250 WORDS)


Asunto(s)
Ecocardiografía , Bloqueo Cardíaco/complicaciones , Insuficiencia de la Válvula Mitral/diagnóstico , Adulto , Anciano , Nodo Atrioventricular/fisiopatología , Diástole , Femenino , Bloqueo Cardíaco/fisiopatología , Humanos , Masculino , Persona de Mediana Edad , Insuficiencia de la Válvula Mitral/etiología , Sístole
20.
J Am Coll Cardiol ; 7(5): 975-81, 1986 May.
Artículo en Inglés | MEDLINE | ID: mdl-3958380

RESUMEN

Doppler echocardiography was performed in 80 consecutive patients (22 men, 58 women), aged 38 +/- 16 years, who had mitral valve prolapse diagnosed by two-dimensional echocardiography. Of the 80 patients, 16 (20%) were asymptomatic and 11 (14%) had a normal physical examination (no click or murmur). The M-mode echocardiogram was negative for mitral valve prolapse in 11 patients (14%) and equivocal or nondiagnostic in 19 patients (24%). Mitral regurgitation was evaluated using pulsed mode Doppler echocardiography and was quantified by the mapping technique as minimal or mild when a holosystolic regurgitant jet was recorded just below the mitral valve into the left atrium, and as moderate or severe when the jet was detected at the mid- or distal left atrium. Mitral regurgitation was found in 55 (69%) of the 80 patients and it was minimal or mild in 47 patients (59%) and moderate or severe in 8 (10%). In 20 (36%) of the 55 patients with mitral regurgitation by Doppler technique, a systolic murmur was not detected and each of the 20 had only mild mitral regurgitation. Left atrial and left ventricular size were significantly smaller in patients with mild or no regurgitation as compared with the eight patients with moderate or severe regurgitation. These eight patients were all men (six over 50 years of age) who usually presented with dyspnea and a holosystolic murmur; the mitral valve prolapse was holosystolic by M-mode and involved both leaflets by two-dimensional echocardiography.(ABSTRACT TRUNCATED AT 250 WORDS)


Asunto(s)
Insuficiencia de la Válvula Mitral/diagnóstico , Prolapso de la Válvula Mitral/diagnóstico , Adolescente , Adulto , Anciano , Ecocardiografía , Femenino , Humanos , Masculino , Persona de Mediana Edad , Insuficiencia de la Válvula Mitral/complicaciones , Prolapso de la Válvula Mitral/complicaciones
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA