1.
Eur Heart J ; 45(5): 346-365, 2024 Feb 01.
Artículo en Inglés | MEDLINE | ID: mdl-38096587

RESUMEN

The role of cardiac implantable electronic device (CIED)-related tricuspid regurgitation (TR) is increasingly recognized as an independent clinical entity. Hence, interventional TR treatment options continuously evolve, surgical risk assessment and peri-operative care improve the management of CIED-related TR, and the role of lead extraction is of high interest. Furthermore, novel surgical and interventional tricuspid valve treatment options are increasingly applied to patients suffering from TR associated with or related to CIEDs. This multidisciplinary review article developed with electrophysiologists, interventional cardiologists, imaging specialists, and cardiac surgeons aims to give an overview of the mechanisms of disease, diagnostics, and proposes treatment algorithms of patients suffering from TR associated with CIED lead(s) or leadless pacemakers.


Asunto(s)
Desfibriladores Implantables , Marcapaso Artificial , Cardiopatía Reumática , Insuficiencia de la Válvula Tricúspide , Humanos , Marcapaso Artificial/efectos adversos , Desfibriladores Implantables/efectos adversos , Válvula Tricúspide/diagnóstico por imagen , Válvula Tricúspide/cirugía , Insuficiencia de la Válvula Tricúspide/cirugía , Insuficiencia de la Válvula Tricúspide/complicaciones , Cardiopatía Reumática/complicaciones , Estudios Retrospectivos
2.
Am Heart J ; 269: 25-34, 2024 Mar.
Artículo en Inglés | MEDLINE | ID: mdl-38072334

RESUMEN

BACKGROUND: Objective data comparing the diagnostic performance of different ambulatory cardiac monitors (ACMs) are lacking. OBJECTIVES: To assess variation in monitoring strategy, clinical outcomes and healthcare utilization in patients undergoing ambulatory monitoring without a pre-existing arrhythmia diagnosis. METHODS: Using the full sample (100%) of Medicare claims data, we performed a retrospective cohort study of diagnostic-naïve patients who received first-time ACM in 2017 to 2018 and evaluated arrhythmia encounter diagnosis at 3-months, repeat ACM testing at 6 months, all-cause 90-day emergency department (ED) and inpatient utilization, and cost of different strategies: Holter; long-term continuous monitor (LTCM); non-continuous, event-based external ambulatory event monitor (AEM); and mobile cardiac telemetry (MCT). We secondarily performed a device-specific analysis by manufacturer, identified from unique claim modifier codes. RESULTS: ACMs were used in 287,789 patients (AEM = 10.3%; Holter = 53.8%; LTCM = 13.3%; MCT = 22.5%). Device-specific analysis showed that compared to Holter, AEM, MCT, or other LTCM manufacturers, a specific LTCM (ZioⓇ XT 14-day patch, iRhythm Technologies, San Francisco, CA) had the highest adjusted odds of diagnosis and lowest adjusted odds of ACM retesting. Findings were consistent for specific arrhythmia diagnoses of ventricular tachycardia, atrioventricular block, and paroxysmal atrial fibrillation. As a category, LTCM was associated with the lowest 1-year incremental health care expenditures (mean Δ$10,159), followed by Holter ($10,755), AEM ($11,462), and MCT ($12,532). CONCLUSIONS: There was large variation in diagnostic monitoring strategy. A specific LTCM was associated with the highest adjusted odds of a new arrhythmia diagnosis and lowest adjusted odds of repeat ACM testing. LTCM as a category had the lowest incremental acute care utilization. Different monitoring strategies may produce different results with respect to diagnosis and care.


Asunto(s)
Fibrilación Atrial , Electrocardiografía Ambulatoria , Metacrilatos , Estados Unidos , Humanos , Anciano , Estudios Retrospectivos , Medicare , Fibrilación Atrial/diagnóstico , Gastos en Salud , Aceptación de la Atención de Salud
3.
J Cardiovasc Electrophysiol ; 35(4): 832-842, 2024 Apr.
Artículo en Inglés | MEDLINE | ID: mdl-38448797

RESUMEN

INTRODUCTION: Cryoablation therapy for pulmonary vein isolation (PVI) to treat paroxysmal atrial fibrillation (PAF) is well established. A novel 28 mm cryoballoon system designed to operate under low pressure to safely reach a lower nadir temperature and maintain constant balloon size during cooling has not been prospectively studied in a large patient population for safety and efficacy. The FROZEN AF (NCT04133168) trial was an international multicenter, open-label, prospective, single-arm study on the safety and performance of a novel cryoballoon system for treatment of PAF. METHODS AND RESULTS: The study enrolled patients at 44 sites in 10 countries across North America, Europe, and Asia. Subjects were indicated for PVI treatment of PAF and had failed or were intolerant of one or more antiarrhythmic drugs. Procedural outcomes were defined based on the 2017 HRS consensus statement. Follow-up was performed at 7 days, 3, 6, and 12 months. Data are reported as mean ± SD or median (IQR). PVI was performed with a 28 mm cryoballoon in 325 drug refractory PAF patients. Complete PVI was achieved in 95.7% of patients. In cryoablation lesions longer than 60 s, 60.1% of PV isolations required only a single cryoballoon application. Procedure related complications included: phrenic nerve palsy [temporary 4 (1.2%), persistent 0 (0.0%)], cardiac tamponade/perforation 2 (0.6%), and air embolism 1 (0.3%). Freedom from documented atrial arrhythmia recurrence at 12 months was 79.9% (AF 82.7%, AFL 96.5%, AT 98.1%), antiarrhythmic drugs (AAD) were continued or re-initiated in 26.8% of patients after the 3-month blanking period. Additionally, an extension arm enrolled 50 pts for treatment with 28/31 mm variable size cryoballoon. A single temporary PNP occurred in this group, which resolved before discharge. Freedom from documented recurrence at 12 months in these pts was 82.0%. CONCLUSIONS: This novel cryoballoon may facilitate PVI to treat PAF, providing more options to address the variety of anatomies present in patients with PAF. This cryoballoon system proved to be safe and effective for treatment of patients with drug refractory or drug intolerant PAF.


Asunto(s)
Fibrilación Atrial , Ablación por Catéter , Criocirugía , Lesiones Cardíacas , Venas Pulmonares , Humanos , Antiarrítmicos/uso terapéutico , Fibrilación Atrial/diagnóstico , Fibrilación Atrial/cirugía , Fibrilación Atrial/epidemiología , Ablación por Catéter/efectos adversos , Ablación por Catéter/métodos , Criocirugía/efectos adversos , Criocirugía/métodos , Lesiones Cardíacas/etiología , Estudios Prospectivos , Venas Pulmonares/cirugía , Recurrencia , Resultado del Tratamiento
4.
JAMA ; 331(13): 1099-1108, 2024 04 02.
Artículo en Inglés | MEDLINE | ID: mdl-38563835

RESUMEN

Importance: Left atrial appendage elimination may improve catheter ablation outcomes for atrial fibrillation. Objective: To assess the safety and effectiveness of percutaneous left atrial appendage ligation adjunctive to catheter pulmonary vein isolation for nonparoxysmal atrial fibrillation. Design, Setting, and Participants: This multicenter, prospective, open-label, randomized clinical trial evaluated the safety and effectiveness of percutaneous left atrial appendage ligation adjunctive to planned pulmonary vein isolation for nonparoxysmal atrial fibrillation present for less than 3 years. Eligible patients were randomized in a 2:1 ratio to undergo left atrial appendage ligation and pulmonary vein isolation or pulmonary vein isolation alone. Use of a 2:1 randomization ratio was intended to provide more device experience and safety data. Patients were enrolled from October 2015 to December 2019 at 53 US sites, with the final follow-up visit on April 21, 2021. Interventions: Left atrial appendage ligation plus pulmonary vein isolation compared with pulmonary vein isolation alone. Main Outcomes and Measures: A bayesian adaptive analysis was used for primary end points. Primary effectiveness was freedom from documented atrial arrythmias of greater than 30 seconds duration 12 months after undergoing pulmonary vein isolation. Rhythm was assessed by Holter monitoring at 6 and 12 months after pulmonary vein isolation, symptomatic event monitoring, or any electrocardiographic tracing obtained through 12 months after pulmonary vein isolation. Primary safety was a composite of predefined serious adverse events compared with a prespecified 10% performance goal 30 days after the procedure. Left atrial appendage closure was evaluated through 12 months after pulmonary vein isolation. Results: Overall, 404 patients were randomized to undergo left atrial appendage ligation plus pulmonary vein isolation and 206 were randomized to undergo pulmonary vein isolation alone. Primary effectiveness was 64.3% with left atrial appendage ligation and pulmonary vein isolation and 59.9% with pulmonary vein isolation only (difference, 4.3% [bayesian 95% credible interval, -4.2% to 13.2%]; posterior superiority probability, 0.835), which did not meet the statistical criterion to establish superiority (0.977). Primary safety was met, with a 30-day serious adverse event rate of 3.4% (bayesian 95% credible interval, 2.0% to 5.0%; posterior probability, 1.0) which was less than the prespecified threshold of 10%. At 12 months after pulmonary vein isolation, complete left atrial appendage closure (0 mm residual communication) was observed in 84% of patients and less than or equal to 5 mm residual communication was observed in 99% of patients. Conclusions and Relevance: Percutaneous left atrial appendage ligation adjunctive to pulmonary vein isolation did not meet prespecified efficacy criteria for freedom from atrial arrhythmias at 12 months compared with pulmonary vein isolation alone for patients with nonparoxysmal atrial fibrillation, but met prespecified safety criteria and demonstrated high rates of closure at 12 months. Trial Registration: ClinicalTrials.gov Identifier: NCT02513797.


Asunto(s)
Apéndice Atrial , Fibrilación Atrial , Compuestos Organotiofosforados , Venas Pulmonares , Humanos , Apéndice Atrial/cirugía , Fibrilación Atrial/cirugía , Teorema de Bayes , Estudios Prospectivos , Venas Pulmonares/cirugía , Ablación por Catéter , Cateterismo
5.
Circulation ; 145(5): 321-329, 2022 02.
Artículo en Inglés | MEDLINE | ID: mdl-34779221

RESUMEN

BACKGROUND: The PRAETORIAN trial (A Prospective, Randomized Comparison of Subcutaneous and Transvenous Implantable Cardioverter Defibrillator Therapy) showed noninferiority of subcutaneous implantable cardioverter defibrillator (S-ICD) compared with transvenous implantable cardioverter defibrillator (TV-ICD) with regard to inappropriate shocks and complications. In contrast to TV-ICD, S-ICD cannot provide antitachycardia pacing for monomorphic ventricular tachycardia. This prespecified secondary analysis evaluates appropriate therapy and whether antitachycardia pacing reduces the number of appropriate shocks. METHODS: The PRAETORIAN trial was an international, investigator-initiated randomized trial that included patients with an indication for implantable cardioverter defibrillator (ICD) therapy. Patients with previous ventricular tachycardia <170 bpm or refractory recurrent monomorphic ventricular tachycardia were excluded. In 39 centers, 849 patients were randomized to receive an S-ICD (n=426) or TV-ICD (n=423) and were followed for a median of 49.1 months. ICD programming was mandated by protocol. Appropriate ICD therapy was defined as therapy for ventricular arrhythmias. Arrhythmias were classified as discrete episodes and storm episodes (≥3 episodes within 24 hours). Analyses were performed in the modified intention-to-treat population. RESULTS: In the S-ICD group, 86 of 426 patients received appropriate therapy, versus 78 of 423 patients in the TV-ICD group, during a median follow-up of 52 months (48-month Kaplan-Meier estimates 19.4% and 17.5%; P=0.45). In the S-ICD group, 83 patients received at least 1 shock, versus 57 patients in the TV-ICD group (48-month Kaplan-Meier estimates 19.2% and 11.5%; P=0.02). Patients in the S-ICD group had a total of 254 shocks, compared with 228 shocks in the TV-ICD group (P=0.68). First shock efficacy was 93.8% in the S-ICD group and 91.6% in the TV-ICD group (P=0.40). The first antitachycardia pacing attempt successfully terminated 46% of all monomorphic ventricular tachycardias, but accelerated the arrhythmia in 9.4%. Ten patients with S-ICD experienced 13 electrical storms, versus 18 patients with TV-ICD with 19 electrical storms. Patients with appropriate therapy had an almost 2-fold increased relative risk of electrical storms in the TV-ICD group compared with the S-ICD group (P=0.05). CONCLUSIONS: In this trial, no difference was observed in shock efficacy of S-ICD compared with TV-ICD. Although patients in the S-ICD group were more likely to receive an ICD shock, the total number of appropriate shocks was not different between the 2 groups. Registration: URL: https://www.clinicaltrials.gov; Unique identifier: NCT01296022.


Asunto(s)
Arritmias Cardíacas/terapia , Desfibriladores Implantables/normas , Anciano , Arritmias Cardíacas/diagnóstico , Femenino , Humanos , Masculino , Persona de Mediana Edad , Estudios Prospectivos , Resultado del Tratamiento
6.
N Engl J Med ; 383(6): 526-536, 2020 08 06.
Artículo en Inglés | MEDLINE | ID: mdl-32757521

RESUMEN

BACKGROUND: The subcutaneous implantable cardioverter-defibrillator (ICD) was designed to avoid complications related to the transvenous ICD lead by using an entirely extrathoracic placement. Evidence comparing these systems has been based primarily on observational studies. METHODS: We conducted a noninferiority trial in which patients with an indication for an ICD but no indication for pacing were assigned to receive a subcutaneous ICD or transvenous ICD. The primary end point was the composite of device-related complications and inappropriate shocks; the noninferiority margin for the upper boundary of the 95% confidence interval for the hazard ratio (subcutaneous ICD vs. transvenous ICD) was 1.45. A superiority analysis was prespecified if noninferiority was established. Secondary end points included death and appropriate shocks. RESULTS: A total of 849 patients (426 in the subcutaneous ICD group and 423 in the transvenous ICD group) were included in the analyses. At a median follow-up of 49.1 months, a primary end-point event occurred in 68 patients in the subcutaneous ICD group and in 68 patients in the transvenous ICD group (48-month Kaplan-Meier estimated cumulative incidence, 15.1% and 15.7%, respectively; hazard ratio, 0.99; 95% confidence interval [CI], 0.71 to 1.39; P = 0.01 for noninferiority; P = 0.95 for superiority). Device-related complications occurred in 31 patients in the subcutaneous ICD group and in 44 in the transvenous ICD group (hazard ratio, 0.69; 95% CI, 0.44 to 1.09); inappropriate shocks occurred in 41 and 29 patients, respectively (hazard ratio, 1.43; 95% CI, 0.89 to 2.30). Death occurred in 83 patients in the subcutaneous ICD group and in 68 in the transvenous ICD group (hazard ratio, 1.23; 95% CI, 0.89 to 1.70); appropriate shocks occurred in 83 and 57 patients, respectively (hazard ratio, 1.52; 95% CI, 1.08 to 2.12). CONCLUSIONS: In patients with an indication for an ICD but no indication for pacing, the subcutaneous ICD was noninferior to the transvenous ICD with respect to device-related complications and inappropriate shocks. (Funded by Boston Scientific; PRAETORIAN ClinicalTrials.gov number, NCT01296022.).


Asunto(s)
Arritmias Cardíacas/terapia , Desfibriladores Implantables/efectos adversos , Anciano , Cardiomiopatías/terapia , Muerte Súbita Cardíaca/epidemiología , Muerte Súbita Cardíaca/prevención & control , Electrodos Implantados/efectos adversos , Falla de Equipo , Femenino , Estudios de Seguimiento , Cardiopatías/terapia , Humanos , Incidencia , Estimación de Kaplan-Meier , Masculino , Persona de Mediana Edad , Diseño de Prótesis
7.
J Cardiovasc Electrophysiol ; 34(2): 348-355, 2023 02.
Artículo en Inglés | MEDLINE | ID: mdl-36448428

RESUMEN

INTRODUCTION: Early and safe ambulation can facilitate same-day discharge (SDD) following catheter ablation, which can reduce resource utilization and healthcare costs and improve patient satisfaction. This study evaluated procedure success and safety of the VASCADE MVP venous vascular closure system in patients with atrial fibrillation (AF). METHODS: The AMBULATE SDD Registry is a two-stage series of postmarket studies in patients with paroxysmal or persistent AF undergoing catheter ablation followed by femoral venous access-site closure with VASCADE MVP. Efficacy endpoints included SDD success, defined as the proportion of patients discharged the same day who did not require next-day hospital intervention for procedure/access site-related complications, and access site sustained success within 15 days of the procedure. RESULTS: Overall, 354 patients were included in the pooled study population, 151 (42.7%) treated for paroxysmal AF and 203 (57.3%) for persistent AF. SDD was achieved in 323 patients (91.2%) and, of these, 320 (99.1%) did not require subsequent hospital intervention based on all study performance outcomes. Nearly all patients (350 of 354; 98.9%) achieved total study success, with no subsequent hospital intervention required. No major access-site complications were recorded. Patients who had SDD were more likely to report procedure satisfaction than patients who stayed overnight. CONCLUSION: In this study, 99.7% of patients achieving SDD required no additional hospital intervention for access site-related complications during follow-up. SDD appears feasible and safe for eligible patients after catheter ablation for paroxysmal or persistent AF in which the VASCADE MVP is used for venous access-site closure.


Asunto(s)
Fibrilación Atrial , Ablación por Catéter , Humanos , Alta del Paciente , Fibrilación Atrial/diagnóstico , Fibrilación Atrial/cirugía , Fibrilación Atrial/etiología , Satisfacción del Paciente , Ablación por Catéter/efectos adversos , Ablación por Catéter/métodos , Sistema de Registros , Resultado del Tratamiento
8.
Europace ; 25(5)2023 05 19.
Artículo en Inglés | MEDLINE | ID: mdl-37208301

RESUMEN

Remote monitoring is beneficial for the management of patients with cardiovascular implantable electronic devices by impacting morbidity and mortality. With increasing numbers of patients using remote monitoring, keeping up with higher volume of remote monitoring transmissions creates challenges for device clinic staff. This international multidisciplinary document is intended to guide cardiac electrophysiologists, allied professionals, and hospital administrators in managing remote monitoring clinics. This includes guidance for remote monitoring clinic staffing, appropriate clinic workflows, patient education, and alert management. This expert consensus statement also addresses other topics such as communication of transmission results, use of third-party resources, manufacturer responsibilities, and programming concerns. The goal is to provide evidence-based recommendations impacting all aspects of remote monitoring services. Gaps in current knowledge and guidance for future research directions are also identified.


Asunto(s)
Monitoreo Fisiológico , Telemetría , Humanos
9.
Eur Heart J ; 43(47): 4872-4883, 2022 12 14.
Artículo en Inglés | MEDLINE | ID: mdl-36030464

RESUMEN

BACKGROUND: The subcutaneous implantable cardioverter-defibrillator (S-ICD) is developed to overcome lead-related complications and systemic infections, inherent to transvenous ICD (TV-ICD) therapy. The PRAETORIAN trial demonstrated that the S-ICD is non-inferior to the TV-ICD with regard to the combined primary endpoint of inappropriate shocks and complications. This prespecified secondary analysis evaluates all complications in the PRAETORIAN trial. METHODS AND RESULTS: The PRAETORIAN trial is an international, multicentre, randomized trial in which 849 patients with an indication for ICD therapy were randomized to receive an S- ICD (N = 426) or TV-ICD (N = 423) and followed for a median of 49 months. Endpoints were device-related complications, lead-related complications, systemic infections, and the need for invasive interventions. Thirty-six device-related complications occurred in 31 patients in the S-ICD group of which bleedings were the most frequent. In the TV-ICD group, 49 complications occurred in 44 patients of which lead dysfunction was most frequent (HR: 0.69; P = 0.11). In both groups, half of all complications were within 30 days after implantation. Lead-related complications and systemic infections occurred significantly less in the S-ICD group compared with the TV-ICD group (P < 0.001, P = 0.03, respectively). Significantly more complications required invasive interventions in the TV-ICD group compared with the S-ICD group (8.3% vs. 4.3%, HR: 0.59; P = 0.047). CONCLUSION: This secondary analysis shows that lead-related complications and systemic infections are more prevalent in the TV-ICD group compared with the S-ICD group. In addition, complications in the TV-ICD group were more severe as they required significantly more invasive interventions. This data contributes to shared decision-making in clinical practice.


Asunto(s)
Muerte Súbita Cardíaca , Desfibriladores Implantables , Humanos , Resultado del Tratamiento , Desfibriladores Implantables/efectos adversos
10.
N Engl J Med ; 380(20): 1895-1905, 2019 05 16.
Artículo en Inglés | MEDLINE | ID: mdl-30883056

RESUMEN

BACKGROUND: Infections after placement of cardiac implantable electronic devices (CIEDs) are associated with substantial morbidity and mortality. There is limited evidence on prophylactic strategies, other than the use of preoperative antibiotics, to prevent such infections. METHODS: We conducted a randomized, controlled clinical trial to assess the safety and efficacy of an absorbable, antibiotic-eluting envelope in reducing the incidence of infection associated with CIED implantations. Patients who were undergoing a CIED pocket revision, generator replacement, or system upgrade or an initial implantation of a cardiac resynchronization therapy defibrillator were randomly assigned, in a 1:1 ratio, to receive the envelope or not. Standard-of-care strategies to prevent infection were used in all patients. The primary end point was infection resulting in system extraction or revision, long-term antibiotic therapy with infection recurrence, or death, within 12 months after the CIED implantation procedure. The secondary end point for safety was procedure-related or system-related complications within 12 months. RESULTS: A total of 6983 patients underwent randomization: 3495 to the envelope group and 3488 to the control group. The primary end point occurred in 25 patients in the envelope group and 42 patients in the control group (12-month Kaplan-Meier estimated event rate, 0.7% and 1.2%, respectively; hazard ratio, 0.60; 95% confidence interval [CI], 0.36 to 0.98; P = 0.04). The safety end point occurred in 201 patients in the envelope group and 236 patients in the control group (12-month Kaplan-Meier estimated event rate, 6.0% and 6.9%, respectively; hazard ratio, 0.87; 95% CI, 0.72 to 1.06; P<0.001 for noninferiority). The mean (±SD) duration of follow-up was 20.7±8.5 months. Major CIED-related infections through the entire follow-up period occurred in 32 patients in the envelope group and 51 patients in the control group (hazard ratio, 0.63; 95% CI, 0.40 to 0.98). CONCLUSIONS: Adjunctive use of an antibacterial envelope resulted in a significantly lower incidence of major CIED infections than standard-of-care infection-prevention strategies alone, without a higher incidence of complications. (Funded by Medtronic; WRAP-IT ClinicalTrials.gov number, NCT02277990.).


Asunto(s)
Antibacterianos/administración & dosificación , Profilaxis Antibiótica , Infecciones Bacterianas/prevención & control , Desfibriladores Implantables/efectos adversos , Cardiopatías/terapia , Minociclina/administración & dosificación , Marcapaso Artificial/efectos adversos , Infecciones Relacionadas con Prótesis/prevención & control , Rifampin/administración & dosificación , Anciano , Antibacterianos/efectos adversos , Infecciones Bacterianas/epidemiología , Infecciones Bacterianas/mortalidad , Femenino , Humanos , Incidencia , Estimación de Kaplan-Meier , Masculino , Persona de Mediana Edad , Minociclina/efectos adversos , Infecciones Relacionadas con Prótesis/epidemiología , Infecciones Relacionadas con Prótesis/mortalidad , Rifampin/efectos adversos , Método Simple Ciego , Nivel de Atención
11.
J Cardiovasc Electrophysiol ; 32(9): 2536-2543, 2021 09.
Artículo en Inglés | MEDLINE | ID: mdl-34270150

RESUMEN

INTRODUCTION: Insertable cardiac monitors (ICMs) provide a minimally invasive method of continuous monitoring for abnormal heart rhythms. While the benefits of ICMs are clear, current algorithm performance can be improved. The objective of this study is to assess the performance of a novel adaptive atrial fibrillation (AF) detection algorithm and separately programmable atrial tachycardia (AT) algorithm. METHODS: A dual-stage detect-and-verify AF algorithm and separately programmable AT algorithm were developed. Sensitivity and PPV across a range of settings were determined in silico by comparison with an adjudicated Holter data set (n = 1966 with 229 patient days). Finally, the ability to improve performance through simulated remote programming was assessed. RESULTS: The dual-stage algorithm detected AF in all true AF patients (76/76) resulting in a patient-level sensitivity of 100%. Episode-level sensitivity and PPV ranged from 97.6% to 100% and 79.1% to 98.5%, respectively. Thirty-six false-positive episodes were observed and 32 (88.9%) of these were corrected with programming changes. Decoupling of AF and AT durations improved PPV from a range of 10%-22% to a range of 95%-100%. CONCLUSIONS: AF and AT algorithms were designed with novel features including an adaptive morphology assessment for AF detection and separately programmable durations for AT detection. In silico performance yielded improved PPVs while maintaining high sensitivity across a range of settings. Importantly, programming changes that may be made remotely with this system reduced false positives. These algorithms allow clinicians to individualize arrhythmia detection settings thereby improving data management and reducing clinic burden.


Asunto(s)
Fibrilación Atrial , Taquicardia Supraventricular , Algoritmos , Fibrilación Atrial/diagnóstico , Simulación por Computador , Electrocardiografía Ambulatoria , Humanos , Taquicardia Supraventricular/diagnóstico
12.
J Cardiovasc Electrophysiol ; 32(2): 191-199, 2021 02.
Artículo en Inglés | MEDLINE | ID: mdl-33270306

RESUMEN

INTRODUCTION: Manual compression (MC), historically the most common method to achieve hemostasis after percutaneous vascular procedures, is time consuming, requires prolonged bedrest, and is uncomfortable for patients and clinicians. Recent studies demonstrate the efficacy and safety of vascular closure devices and suggest shorter times to hemostasis and patient ambulation compared with MC. The current study evaluated the feasibility of the VASCADE® venous vascular closure system (VVCS) while allowing for urinary catheter (UC) elimination, and elimination of protamine and/or same calendar day discharge (SCDD). METHODS AND RESULTS: In this prospective, multicenter trial, patients were enrolled and assigned to the following groups: no UC, no protamine, and/or SCDD (no co-enrollment in no protamine and SCDD). After completing the catheter-based cardiac procedure, access sites were closed using the VVCS. Outcomes included final hemostasis (all sites) without major access site-related complications at 30 days, rates of access site closure-related complications, device success, and study group success. All 168 patients had hemostasis without major access site-related complications through 30 days. In the no UC group, 160 out of 164 (97.6%) patients did not receive a UC. Additionally, 39 out of 41 (95.1%) patients received heparin without protamine reversal and no access site bleeding-related ambulation delays, and 18 out of 18 (100%) patients were discharged on the same day. There were no major access site closure-related complications, few minor complications, and adverse events were generally mild and well managed. CONCLUSION: The VVCS was effective for achieving hemostasis following catheter-based procedures; access site closure-related complications and adverse events were well managed.


Asunto(s)
Protaminas , Catéteres Urinarios , Arteria Femoral , Hemostasis , Técnicas Hemostáticas/efectos adversos , Humanos , Estudios Prospectivos , Protaminas/efectos adversos , Resultado del Tratamiento
13.
J Cardiovasc Electrophysiol ; 31(1): 286-292, 2020 01.
Artículo en Inglés | MEDLINE | ID: mdl-31724791

RESUMEN

Pacing induced cardiomyopathy (PICM) is most commonly defined as a drop in left ventricle ejection fraction (LVEF) in the setting of chronic, high burden right ventricle (RV) pacing. Recent data suggest, however, that some individuals may experience the onset of heart failure symptoms more acutely after pacemaker implantation. Definitions of PICM which emphasize drop in LVEF may underestimate the incidence of deleterious effects from RV pacing. Treatment of PICM has primarily focused on upgrade to cardiac resynchronization therapy (CRT) when LVEF has dropped. However, emerging data suggest that conduction system pacing (CSP) may offer an opportunity to prevent PICM in the first place.


Asunto(s)
Arritmias Cardíacas/terapia , Estimulación Cardíaca Artificial/efectos adversos , Cardiomiopatías/etiología , Volumen Sistólico , Función Ventricular Izquierda , Animales , Arritmias Cardíacas/diagnóstico , Arritmias Cardíacas/fisiopatología , Terapia de Resincronización Cardíaca/efectos adversos , Cardiomiopatías/diagnóstico , Cardiomiopatías/fisiopatología , Cardiomiopatías/prevención & control , Humanos , Factores de Riesgo , Resultado del Tratamiento , Función Ventricular Derecha
14.
Pacing Clin Electrophysiol ; 43(12): 1467-1475, 2020 12.
Artículo en Inglés | MEDLINE | ID: mdl-32662101

RESUMEN

INTRODUCTION: The third-generation subcutaneous implantable cardioverter-defibrillator (S-ICD) (EMBLEM™ A219, Boston Scientific) contains a new diagnostic tool to detect atrial fibrillation (AF) in S-ICD patients, without the use of an intracardiac lead. This is the first study to evaluate the performance of the S-ICD AF monitor (AFM). METHODS: The AFM algorithm analyzes a subcutaneous signal for the presence of AF, similar to the signals collected by implantable and wearable diagnostic devices. The AFM algorithm combines heart rate (HR) scatter analysis with an HR histogram. The algorithm was tested against publicly available electrocardiogram databases (simulated performance). Real-world performance of the algorithm was evaluated by using the S-ICD LATITUDE remote monitoring (RM) database. RESULTS: The simulated performance of the AFM algorithm resulted in a sensitivity of 95.0%, specificity of 100.0%, and positive predictive value (PPV) of 100.0%. To evaluate the real-world performance of the AFM, 7744 S-ICD devices were followed for up to 30 months by RM, whereof 99.5% had the AFM enabled. A total of 387 AF episodes were randomly chosen for adjudication, resulting in a PPV of 67.7%. The main cause of misclassification was atrial and ventricular ectopy. CONCLUSION: The AFM exhibited a very high sensitivity and specificity in a simulated setting, designed to maximize PPV in order to minimize the clinical burden of reviewing falsely detected AF events. The real-world performance of the AFM, enabled in 99.5% of S-ICD patients, is a PPV of 67.7%.


Asunto(s)
Algoritmos , Fibrilación Atrial/diagnóstico , Desfibriladores Implantables , Adulto , Anciano , Fibrilación Atrial/fisiopatología , Electrocardiografía , Femenino , Frecuencia Cardíaca , Humanos , Masculino , Persona de Mediana Edad , Sensibilidad y Especificidad
15.
Am Heart J ; 207: 76-82, 2019 01.
Artículo en Inglés | MEDLINE | ID: mdl-30487072

RESUMEN

BACKGROUND: Traditionally, insertable cardiac monitor (ICM) procedures have been performed in the cardiac catheterization (CATH) or electrophysiology (EP) laboratory. The introduction of the miniaturized Reveal LINQ ICM has led to simplified and less invasive procedures, affording hospitals flexibility in planning where these procedures occur without compromising patient safety or outcomes. METHODS: The present analysis of the ongoing, prospective, observational, multicenter Reveal LINQ Registry sought to provide real-world feasibility and safety data regarding the ICM procedure performed in the CATH/EP lab or operating room and to compare it with insertions performed outside of these traditional hospital settings. Patients included had at least a 30-day period after the procedure to account for any adverse events. RESULTS: We analyzed 1222 patients (58.1% male, age 61.0 ± 17.1 years) enrolled at 18 centers in the US, 17 centers in Middle East/Asia, and 15 centers in Europe. Patients were categorized into 2 cohorts according to the location of the procedure: in-lab (CATH lab, EP lab, or operating room) (n = 820, 67.1%) and out-of-lab (n = 402, 32.9%). Several differences were observed regarding baseline and procedure characteristics. However, no significant differences in the occurrence of procedure-related adverse events (AEs) were found; of 19 ICM/procedure-related AEs reported in 17 patients (1.4%), 11 occurred in the in-lab group (1.3%) and 6 in the out-of-lab group (1.5%) (P = .80). CONCLUSIONS: This real-world analysis demonstrates the feasibility of performing Reveal LINQ ICM insertion procedures outside of the traditional hospital settings without increasing the risk of infection or other adverse events.


Asunto(s)
Cateterismo Cardíaco/estadística & datos numéricos , Unidades de Cuidados Coronarios/estadística & datos numéricos , Técnicas Electrofisiológicas Cardíacas/métodos , Quirófanos/estadística & datos numéricos , Adolescente , Adulto , Anciano , Anciano de 80 o más Años , Cateterismo Cardíaco/efectos adversos , Niño , Preescolar , Técnicas Electrofisiológicas Cardíacas/efectos adversos , Técnicas Electrofisiológicas Cardíacas/estadística & datos numéricos , Europa (Continente) , Asia Oriental , Estudios de Factibilidad , Femenino , Humanos , Lactante , Masculino , Persona de Mediana Edad , Miniaturización , Seguridad del Paciente , Estudios Prospectivos , Sistema de Registros , Estados Unidos , Adulto Joven
16.
J Cardiovasc Electrophysiol ; 30(12): 2849-2857, 2019 12.
Artículo en Inglés | MEDLINE | ID: mdl-31596044

RESUMEN

BACKGROUND: Left atrial appendage closure (LAAC) with LARIAT has emerged as one of the alternatives to oral anticoagulation (OAC) in patients with nonvalvular atrial fibrillation (AF). Our aim was to study long-term outcomes in patients undergoing LARIAT procedure. METHODS: We analyzed patients screened for LARIAT device in four centers between December 2009 and June 2012. Out of these, patients who didn't undergo LAAC with the LARIAT device due to unfavorable LAA morphology and other preprocedural contraindications were included in control group. We analyzed thromboembolism, bleeding events, and mortality between LAA and control group. RESULTS: About 153 patients were screened. Out of these, 108 (70.6%) patients underwent LARIAT placement (LAA arm) and 45 (29.4%) excluded patients were included in control arm. There were no differences in CHADS2 and CHA2 DS2 -VASc score. Mean HAS-BLED score was significantly higher in the LARIAT group (3.5 ± 1.06 vs 3.09 ± 1.22, P = .04). Mean follow-up time (in years) was 6.56 ± 0.84 in LAA and 6.5 ± 1.26 in control arm. During follow-up period, the LARIAT group was associated with significantly less thromboembolic events (1.9% vs 24%, P < .001), bleeding events (9.2% vs 24.4%, P = .03), and mortality (5.6% vs 20%, P = .01) as compared with the control group. CONCLUSIONS: Long-term data from routine clinical practice from our study suggests that LAA exclusion with LARIAT device is an effective treatment in management of nonvalvular AF patients with high risk of stroke, bleeding, and mortality. Further randomized trials, such as aMAZE, will provide more insight in this expanding field.


Asunto(s)
Apéndice Atrial/cirugía , Fibrilación Atrial/cirugía , Función del Atrio Izquierdo , Procedimientos Quirúrgicos Cardíacos/instrumentación , Frecuencia Cardíaca , Potenciales de Acción , Anciano , Apéndice Atrial/fisiopatología , Fibrilación Atrial/diagnóstico , Fibrilación Atrial/mortalidad , Fibrilación Atrial/fisiopatología , Procedimientos Quirúrgicos Cardíacos/efectos adversos , Procedimientos Quirúrgicos Cardíacos/mortalidad , Femenino , Fibrinolíticos/administración & dosificación , Hemorragia/mortalidad , Hemorragia/prevención & control , Humanos , Incidencia , Ligadura , Masculino , Persona de Mediana Edad , Polonia , Estudios Prospectivos , Sistema de Registros , Medición de Riesgo , Factores de Riesgo , Accidente Cerebrovascular/mortalidad , Accidente Cerebrovascular/prevención & control , Tromboembolia/mortalidad , Tromboembolia/prevención & control , Factores de Tiempo , Resultado del Tratamiento , Estados Unidos
18.
Ann Noninvasive Electrocardiol ; 23(2): e12491, 2018 Mar.
Artículo en Inglés | MEDLINE | ID: mdl-28940909

RESUMEN

BACKGROUND: Frequent ventricular ectopy on preimplantation Holter has been associated with attenuated benefit from cardiac resynchronization therapy (CRT). However, it is unclear whether ectopic burden measured post-CRT implantation can be utilized to evaluate long-term prognosis. We aimed to describe the association between post-CRT implantation ectopic burden and subsequent risk of clinical outcomes. METHODS: At the 12-month follow-up visit, 24-hour Holter recordings were performed in 698 CRT-D patients from the MADIT-CRT study. The mean number of ventricular premature complexes (VPCs/hour) was calculated. High ectopic burden was defined as >10 VPCs/hour and low burden as ≤10 VPCs/hour. Multivariate Cox proportional hazards models were utilized to assess the association between 12-month ectopic burden and the risk of the end points of heart failure (HF) or death and ventricular tachyarrhythmias (VT/VF). RESULTS: At 12 months, 282 (40%) patients presented with low ectopic burden and 416 (60%) patients presented with high ectopic burden. The 3-year risk of HF/death and VT/VF was lower in patients with a low burden (7% and 8%) and significantly higher (25% and 24%) in patients with high burden. In multivariate analyses, patients with a high ectopic burden had approximately threefold increased risk of both HF/death (HR=2.76 [1.62-4.70], p < .001) and VT/VF (HR=2.79 [1.69-4.58], p < .001). CONCLUSION: In CRT-D patients with mild heart failure, high ectopic burden at 12-month follow-up was associated with a high 3-year risk of HF/death and VT/VF and threefold increased risk as compared to patients with low burden. Ectopic burden at 12 months may be a valuable approach for evaluating long-term prognosis.


Asunto(s)
Desfibriladores Implantables/efectos adversos , Electrocardiografía Ambulatoria/métodos , Insuficiencia Cardíaca/mortalidad , Fibrilación Ventricular/mortalidad , Complejos Prematuros Ventriculares/diagnóstico por imagen , Complejos Prematuros Ventriculares/epidemiología , Anciano , Terapia de Resincronización Cardíaca/efectos adversos , Electrocardiografía/métodos , Femenino , Insuficiencia Cardíaca/etiología , Humanos , Incidencia , Internacionalidad , Masculino , Persona de Mediana Edad , Pronóstico , Medición de Riesgo , Índice de Severidad de la Enfermedad , Tasa de Supervivencia , Taquicardia Ventricular/diagnóstico por imagen , Taquicardia Ventricular/terapia , Fibrilación Ventricular/diagnóstico , Fibrilación Ventricular/etiología , Complejos Prematuros Ventriculares/etiología
19.
Am Heart J ; 187: 156-169, 2017 May.
Artículo en Inglés | MEDLINE | ID: mdl-28454799

RESUMEN

This white paper, prepared by members of the Cardiac Safety Research Consortium (CSRC), discusses important issues regarding scientific and clinical aspects of long-term electrocardiographic safety monitoring during clinical drug development. To promote multistakeholder discussion of this topic, a Cardiac Safety Research Consortium-sponsored Think Tank was held on 2 December 2015 at the American College of Cardiology's Heart House in Washington, DC. The goal of the Think Tank was to explore how and under what circumstances new and evolving ambulatory monitoring technologies could be used to improve and streamline drug development. This paper provides a detailed summary of discussions at the Think Tank: it does not represent regulatory guidance.


Asunto(s)
Evaluación de Medicamentos , Monitoreo de Drogas/métodos , Electrocardiografía , Arritmias Cardíacas/inducido químicamente , Electrocardiografía/instrumentación , Electrocardiografía/métodos , Humanos
SELECCIÓN DE REFERENCIAS