Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 7 de 7
Filtrar
1.
Ergonomics ; 62(6): 759-766, 2019 Jun.
Artículo en Inglés | MEDLINE | ID: mdl-30773103

RESUMEN

This study aimed to evaluate objective and subjective visual fatigue experienced before and after performing a visual task while using a head-mounted display for virtual reality (VR-HMD) and two-dimensional (2D) display. Binocular fusion maintenance (BFM) was measured using a binocular open-view Shack-Hartmann wavefront aberrometer equipped with liquid crystal shutters. Twelve healthy subjects performed the BFM test and completed a questionnaire regarding subjective symptoms before and after performing a visual task that induces low visually induced motion sickness (VIMS). BFM (p = .87) and total subjective eye symptom scores (p = .38) were not significantly different between both groups, although these values were significantly lower after the visual task than before the task within both groups (p < .05). These findings suggest that visual fatigue after using a VR-HMD is not significantly different from that after using a 2D display in the presence of low-VIMS VR content. Practitioner summary: Objective and subjective evaluation of visual fatigue were not significantly different with the use of a head-mounted display for virtual reality (VR-HMD) and two-dimensional display. These results should be valuable not only to engineers developing VR content but also to researchers involved in the evaluation of visual fatigue using VR-HMD. Abbreviations: VR: virtual reality; VR-HMD: head-mounted display for virtual reality; BFM: binocular fusion maintenance; BWFA: binocular open-view Shack-Hartmann wavefront aberrometer.


Asunto(s)
Fatiga Mental/psicología , Gafas Inteligentes/psicología , Interfaz Usuario-Computador , Realidad Virtual , Percepción Visual , Adulto , Femenino , Humanos , Masculino , Análisis y Desempeño de Tareas
2.
PLoS One ; 15(3): e0230788, 2020.
Artículo en Inglés | MEDLINE | ID: mdl-32214343

RESUMEN

PURPOSE: The purpose of this study was to evaluate the degree of visual fatigue in patients with intermittent exotropia (IXT) using the binocular fusion maintenance (BFM) test. METHODS: Fourteen patients with IXT (32.1 ± 16.4 years) and 15 age-matched healthy volunteers (31.2 ± 9.3 years) participated in the study. BFM was assessed by measuring the transmittance of liquid crystals placed in front of the subject's nondominant eye at the instance when binocular fusion was broken and vergence eye movement was induced. A questionnaire on subjective symptoms was administered to the subjects before and after the visual task. The visual task consisted of a reciprocal movement between 67 and 40 cm. RESULTS: The change [post-pre] of BFM was significantly lower in the IXT group (-0.185 ± 0.187) than in the control group (-0.030 ± 0.070) (P = 0.010). The change of total subjective eye symptom score was significantly greater in the IXT group (2.28 ± 1.43) than in the control group (0.93 ± 1.27) (P = 0.018). The reduction in BFM rate with increasing total subjective eye symptom score was significantly greater in the IXT group (-0.106 ± 0.017) than in the control group (-0.030 ± 0.013) (P = 0.006). CONCLUSION: The present findings objectively showed that patients with IXT are at a greater risk of visual fatigue in comparison with healthy individuals.


Asunto(s)
Exotropía/fisiopatología , Visión Ocular , Adolescente , Adulto , Estudios de Casos y Controles , Femenino , Humanos , Masculino , Persona de Mediana Edad , Adulto Joven
3.
Transl Vis Sci Technol ; 7(2): 9, 2018 Mar.
Artículo en Inglés | MEDLINE | ID: mdl-29600117

RESUMEN

PURPOSE: In this study, we investigated whether an individual's visual fatigue can be evaluated objectively and quantitatively from their ability to maintain binocular fusion. METHODS: Binocular fusion maintenance (BFM) was measured using a custom-made binocular open-view Shack-Hartmann wavefront aberrometer equipped with liquid crystal shutters, wherein eye movements and wavefront aberrations were measured simultaneously. Transmittance in the liquid crystal shutter in front of the subject's nondominant eye was reduced linearly, and BFM was determined from the transmittance at the point when binocular fusion was broken and vergence eye movement was induced. In total, 40 healthy subjects underwent the BFM test and completed a questionnaire regarding subjective symptoms before and after a visual task lasting 30 minutes. RESULTS: BFM was significantly reduced after the visual task (P < 0.001) and was negatively correlated with the total subjective eye symptom score (adjusted R2 = 0.752, P < 0.001). Furthermore, the diagnostic accuracy for visual fatigue was significantly higher in BFM than in the conventional test results (aggregated fusional vergence range, near point of convergence, and the high-frequency component of accommodative microfluctuations; P = 0.007). CONCLUSIONS: These results suggest that BFM can be used as an indicator for evaluating visual fatigue. TRANSLATIONAL RELEVANCE: BFM can be used to evaluate the visual fatigue caused by the new visual devices, such as head-mount display, objectively.

4.
Clin Ophthalmol ; 11: 781-790, 2017.
Artículo en Inglés | MEDLINE | ID: mdl-28479850

RESUMEN

PURPOSE: The purpose of this study was to develop an algorithm based on region-based segmentation for automated calculations of human cone photoreceptor density of en face images obtained by an adaptive optics scanning laser ophthalmoscope (AOSLO). SUBJECTS AND METHODS: Cone mosaics of 15 eyes of 15 healthy subjects were photographed by a custom-built AOSLO. The cone density was calculated at 0.5, 1.0, and 1.5 mm temporal from the fovea using a region-based segmentation method (RSM) developed in our laboratory. The cone density was also determined by a manual identification method (MIM) and a conventional spatial filtering method (SFM). The cone densities of three eyes of three patients with retinal degeneration were calculated by the three methods and compared to the results from normal eyes. RESULTS: The cone densities in healthy retinas determined by the RSM at 0.5, 1.0, and 1.5 mm temporal from the fovea were 28,436, 21,233, and 13,620 cells/mm2, respectively. These densities were in good agreement with a histological study and with in vivo AOSLO studies. The cone densities determined by RSM were different from those determined by MIM with a difference of 5% in healthy eyes. In eyes with retinal degeneration, with the appropriate threshold-level settings or spatial frequency bandwidth, the cone density measured by MIM was significantly closer to that measured by RSM than by SFM. CONCLUSION: These results suggest that our method is more stable than conventional methods in cases of non-periodical photoreceptor structures such as the affected retinal area. Our method can be used in the longitudinal follow-up of retinal degenerative diseases and to determine the effect of therapy.

5.
Ophthalmic Surg Lasers Imaging Retina ; 48(2): 106-113, 2017 02 01.
Artículo en Inglés | MEDLINE | ID: mdl-28195612

RESUMEN

BACKGROUND AND OBJECTIVE: To investigate the relationship between spatial contrast sensitivity (CS) and parafoveal cone density (PCD). PATIENTS AND METHODS: Fifteen healthy individuals (mean age: 26.1 years ± 4.5 years) and nine patients with hereditary retinal degeneration (mean age: 31.6 years ± 13.4 years) without media opacities were studied. The CS was measured by CSV-1000 (VectorVision, Greenville, OH). The cone mosaic was photographed with an adaptive optics scanning laser ophthalmoscope (AOSLO) with a 1° × 1° field of view centered on the fovea. The PCD was calculated in an annular area with radii of 0.38° and 0.43°. The CS was converted to the logarithm (logCS), and the area under the logCS function (AULCSF) was determined. RESULTS: The AULCSF was significantly and positively correlated with the PCD in the control (R2 = 0.522; P = .003) and retinal degeneration (R2 = 0.514; P = .03) groups. CONCLUSION: PCD can predict the spatial contrast sensitivity in normal subjects or patients with retinal degeneration without media opacities. [Ophthalmic Surg Lasers Imaging Retina. 2017;48:106-113.].


Asunto(s)
Sensibilidad de Contraste/fisiología , Fóvea Central/patología , Células Fotorreceptoras Retinianas Conos/patología , Degeneración Retiniana/fisiopatología , Adolescente , Adulto , Recuento de Células , Niño , Femenino , Angiografía con Fluoresceína , Fondo de Ojo , Humanos , Masculino , Persona de Mediana Edad , Oftalmoscopía , Degeneración Retiniana/diagnóstico , Tomografía de Coherencia Óptica/métodos , Adulto Joven
6.
PLoS One ; 10(6): e0131485, 2015.
Artículo en Inglés | MEDLINE | ID: mdl-26121666

RESUMEN

To investigate the changes in the reflectance of human cone photoreceptors by an adaptive optics scanning laser ophthalmoscope (AO-SLO) during photobleaching. A custom-built AO-SLO with an observation light of 840-nm was used to measure the cone densities and the reflectance changes during bleaching by 630 nm red light emitting diodes. Measurements were made at 1° and 3° temporal to the fovea within an area of 1° × 1° in 8 eyes of 8 normal subjects. After dark-adaptation, images of the cone mosaics were recorded continuously for 5-min before, 5-min during, and after 5-min of light stimulation with a sampling rate of 5-Hz. The first positive peak (P1) was observed at 72.2 ± 15.0-s and a second positive peak (P2) at 257.5 ± 34.5-s at 1°. The increase of the reflectance of P1 was significantly larger at 1° (34.4 ± 13.9%) than at 3° (26.0 ± 10.5%; P = 0.03, Wilcoxon's signed rank test). The average cone density at 1° (51123.13 ± 1401.23 cells/mm2) was significantly larger than that at 3° (30876.13 ± 1459.28 cells/mm2; P <0.001, Wilcoxon's signed rank test). The changes in the reflectance of the cones during bleaching by red light had two peaks. The two peaks may be caused by regeneration of cone photopigment during bleaching.


Asunto(s)
Adaptación Ocular/efectos de la radiación , Rayos Láser , Oftalmoscopios , Óptica y Fotónica/instrumentación , Fotoblanqueo , Células Fotorreceptoras Retinianas Conos/fisiología , Células Fotorreceptoras Retinianas Conos/efectos de la radiación , Adulto , Fóvea Central , Humanos , Estimulación Luminosa , Factores de Tiempo , Adulto Joven
7.
PLoS One ; 9(8): e105615, 2014.
Artículo en Inglés | MEDLINE | ID: mdl-25144536

RESUMEN

To investigate the changes in the wavefront aberrations and pupillary shape in response to electrical stimulation of the branches of the ciliary nerves in cats. Seven eyes of seven cats were studied under general anesthesia. Trains of monophasic pulses (current, 0.1 to 1.0 mA; duration, 0.5 ms/phase; frequency, 5 to 40 Hz) were applied to the lateral or medial branch of the short ciliary nerve near the posterior pole of the eye. A pair of electrodes was hooked onto one or both branch of the short ciliary nerve. The electrodes were placed about 5 mm from the scleral surface. The wavefront aberrations were recorded continuously for 2 seconds before, 8 seconds during, and for 20 seconds after the electrical stimulation. The pupillary images were simultaneously recorded during the stimulation period. Both the wavefront aberrations and the pupillary images were obtained 10 times/sec with a custom-built wavefront aberrometer. The maximum accommodative amplitude was 1.19 diopters (D) produced by electrical stimulation of the short ciliary nerves. The latency of the accommodative changes was very short, and the accommodative level gradually increased up to 4 seconds and reached a plateau. When only one branch of the ciliary nerve was stimulated, the pupil dilated asymmetrically, and the oblique astigmatism and one of the asymmetrical wavefront terms was also altered. Our results showed that the wavefront aberrations and pupillary dilations can be measured simultaneously and serially with a compact wavefront aberrometer. The asymmetric pupil dilation and asymmetric changes of the wavefront aberrations suggest that each branch of the ciliary nerve innervates specific segments of the ciliary muscle and dilator muscle of the pupil.


Asunto(s)
Aberrometría , Estimulación Eléctrica , Tejido Nervioso , Pupila/fisiología , Animales , Gatos , Aberración de Frente de Onda Corneal/diagnóstico
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA