Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 80
Filtrar
Más filtros

Bases de datos
País/Región como asunto
Tipo del documento
País de afiliación
Intervalo de año de publicación
1.
Respiration ; 100(7): 611-617, 2021.
Artículo en Inglés | MEDLINE | ID: mdl-33946078

RESUMEN

BACKGROUND: The positioning of the stent at the flow-limiting segment is crucial for patients with extensive airway obstruction to relieve dyspnea. However, CT and flow-volume curves cannot detect the area of maximal obstruction. OBJECTIVES: The aim of this study is to physiologically evaluate extensive airway obstruction during interventional bronchoscopy. METHODS: We prospectively measured point-by-point lateral airway pressure (Plat) at multiple points from the lower lobe bronchus to the upper trachea using a double-lumen catheter in 5 patients. The site of maximal obstruction was evaluated continuously to measure point-by-point Plat at multiple points when the airway catheter was withdrawn from the lower lobe bronchus to the upper trachea. RESULTS: Remarkable pressure differences occurred at the site of maximal obstruction assessed by point-by-point Plat measurements. After initial stenting in 1 case, migration of the maximal obstruction to a nonstented segment of the weakened airway was seen with extensive stenosis from the trachea to the bronchi. In the second case, in addition to radiological analysis, point-by-point Plat measurements could identify the location of the maximal obstruction which contributed to dyspnea. CONCLUSIONS: Point-by-point Plat measurement could be used to detect the site of maximal obstruction physiologically. Furthermore, Plat measurement could assess the need for additional procedures in real time in patients with extensive airway obstruction.


Asunto(s)
Obstrucción de las Vías Aéreas/diagnóstico , Bronquios/fisiopatología , Enfermedades Bronquiales/diagnóstico , Broncoscopía/métodos , Tráquea/fisiopatología , Estenosis Traqueal/diagnóstico , Anciano , Obstrucción de las Vías Aéreas/fisiopatología , Bronquios/patología , Enfermedades Bronquiales/fisiopatología , Constricción Patológica/diagnóstico , Femenino , Humanos , Masculino , Persona de Mediana Edad , Presión , Estudios Prospectivos , Stents , Estenosis Traqueal/fisiopatología
2.
J Asthma ; 57(11): 1173-1178, 2020 11.
Artículo en Inglés | MEDLINE | ID: mdl-31449432

RESUMEN

Introduction: Bronchial asthma (BA) and obstructive sleep apnea syndrome (OSAS) are common causes of respiratory disturbance. Many cases of patients with both conditions have been reported, and BA and OSAS may exacerbate each other, but information remains sparse.Methods:We retrospectively evaluated 60 patients under treatment for BA in our department between April 2016 and March 2018 who also underwent portable polysomnography (PSG) for suspected OSAS to assess potential association between PSG results and asthma treatment or respiratory function. BA was diagnosed and treated according to the Asthma Prevention and Management Guideline 2015.Results: We found that BA treatment intensity step was significantly higher for patients with BA who had concurrent moderate or severe OSAS (p = 0.0016). However, neither respiratory function, fraction of exhaled nitric oxide (FeNO), nor forced oscillation technique (FOT) differed significantly between patients with and without OSAS, and apnea hypopnea index was not significantly correlated with respiratory function, FeNO or FOT parameters.Conclusion:We conclude that even though BA patients with OSAS had good respiratory function, their BA was more severe than that of patients without OSAS, suggesting that OSAS may exacerbate BA. Background factors and asthma parameters were not predictive of PSG results, and patients with suspected OSAS should be evaluated proactively by using PSG.


Asunto(s)
Asma/diagnóstico , Índice de Severidad de la Enfermedad , Apnea Obstructiva del Sueño/complicaciones , Anciano , Antiasmáticos/uso terapéutico , Asma/tratamiento farmacológico , Femenino , Humanos , Masculino , Persona de Mediana Edad , Polisomnografía , Pruebas de Función Respiratoria , Estudios Retrospectivos , Apnea Obstructiva del Sueño/diagnóstico , Teratoma
3.
BMC Cancer ; 19(1): 546, 2019 Jun 07.
Artículo en Inglés | MEDLINE | ID: mdl-31174496

RESUMEN

BACKGROUND: Programmed cell death-1 (PD-1) immune checkpoint inhibitor antibody has proven to be effective in advanced non-small cell lung cancer (NSCLC) patients positive for programmed cell death-1 ligand-1 (PD-L1). However, there are currently no prospective studies evaluating PD-L1 expression for small biopsy samples. METHODS: To prospectively investigate the reliability of small samples for NSCLC, we included patients who underwent diagnostic biopsy by flexible bronchoscopy, computed tomography (CT) and ultra-sonography (US) guided core-needle to determine the PD-L1 expression status. In pathologically confirmed NSCLC, PD-L1 expression was evaluated using companion diagnostic PD-L1 immunohistochemistry. We evaluated: 1) tumor cell count and sample size, 2) tumor proportion score (TPS): <1, 1-49%, 50%≦, and 3) the concordance rate of TPS by biopsy and surgical samples. RESULTS: Of the 153 cases of PD-L1 expression, 110 were assessed using endobronchial ultrasonography guided transbronchial biopsy (EBUS-TBB) (thin bronchoscopy 84 cases; normal bronchoscopy 26 cases), 23 were endobronchial ultrasonography guided transbronchial needle aspiration (EBUS-TBNA), and 20 cases of CT or US-guided core-needle biopsy. Tumor cell count and sample size were significantly larger for normal bronchoscopy than thin bronchoscopy or EBUS-TBNA samples. Moreover, tumor cell counts for each subsequent biopsy decreased. In all cases, TPS distribution (undiagnosed, <1%, 1-49, 50%≦) was 2.6, 34.6, 31.4, 31.4%, respectively. TPS positive cases using thin bronchoscope was 55.9%, normal bronchoscope was 73.1% and EBUS-TBNA was 78.3%. In early stage adenocarcinoma, TPS was lower compared with advanced stages. Conversely, in squamous cell carcinoma, the rates of TPS were similar regardless of stage. The concordance rate of TPS by biopsy and surgical materials was 86.7%. CONCLUSION: Utilizing smaller samples for evaluation, the frequency of TPS was comparable to past clinical trials using larger samples. The differences in TPS were influenced by diagnostic tools, cancer histologic types and staging. The concordance of TPS between EBUS-TBB samples and surgical materials was high. TRIAL REGISTRATION: This study was performed at the Department of Respiratory Medicine at St. Marianna University School of Medicine Hospital, with ethics approval (#3590) and registered as a clinical trial ( UMIN000027030 ).


Asunto(s)
Antígeno B7-H1/genética , Carcinoma de Pulmón de Células no Pequeñas/diagnóstico , Carcinoma de Pulmón de Células no Pequeñas/genética , Expresión Génica , Neoplasias Pulmonares/diagnóstico , Neoplasias Pulmonares/genética , Adulto , Anciano , Anciano de 80 o más Años , Antígeno B7-H1/metabolismo , Broncoscopía/métodos , Carcinoma de Pulmón de Células no Pequeñas/metabolismo , Femenino , Humanos , Biopsia Guiada por Imagen , Inmunohistoquímica , Neoplasias Pulmonares/metabolismo , Masculino , Persona de Mediana Edad , Tomografía Computarizada por Tomografía de Emisión de Positrones , Estudios Prospectivos , Tomografía Computarizada por Rayos X , Ultrasonografía
4.
Respirology ; 24(4): 369-375, 2019 04.
Artículo en Inglés | MEDLINE | ID: mdl-30468280

RESUMEN

BACKGROUND AND OBJECTIVE: We previously reported that histogram-based quantitative evaluation for endobronchial ultrasonography (EBUS) B-mode images could differentiate between benign and malignant lesions. However, these images were generated from reconstructed raw radiofrequency (RF) signals and had some limitations. Currently, there are no reports on raw RF signal data to quantitatively differentiate ultrasound information for peripheral pulmonary lesions. METHODS: We prospectively hypothesized that RF spectral analysis from EBUS images could reveal sonographic features of peripheral pulmonary diseases. RF data were imported into a frequency spectral analysis software programme, comparing four parameters: mean frequency (MHz); slope; mid-band fit (dB); and y-intercept (dB), to differentiate between benign and malignant lesions. Furthermore, we compared subgroup analysis within benign and malignant lesions. RESULTS: RF data from EBUS images were obtained in 146 cases, of which, 106 lung cancers and 40 inflammatory diseases were present. Significant differences were observed for three parameters in benign and malignant lesions (mean frequency: P < 0.05, slope: P < 0.05, y-intercept: P < 0.01) with diagnostic accuracy of 61%, 57.5%, 63%, respectively. In subgroup analysis, the acute pneumonia group showed higher mean frequency, higher slope and lower y-intercept patterns compared to mycobacterial and fibrotic diseases (P < 0.05). In malignant lesions, small cell carcinoma showed higher mean frequency, higher slope and lower y-intercept pattern compared to other histopathological lung cancers (P < 0.01). CONCLUSION: RF analysis might be capable of demonstrating aspects of the lesion's pathological heterogeneity rather than precisely differentiating between benign and malignant lesions.


Asunto(s)
Endosonografía/métodos , Neoplasias Pulmonares/diagnóstico por imagen , Neumonía/diagnóstico por imagen , Ondas de Radio , Carcinoma Pulmonar de Células Pequeñas/diagnóstico por imagen , Broncoscopía , Humanos , Procesamiento de Imagen Asistido por Computador , Neoplasias Pulmonares/patología , Carcinoma Pulmonar de Células Pequeñas/patología , Análisis Espectral
5.
Jpn J Clin Oncol ; 48(4): 376-381, 2018 Apr 01.
Artículo en Inglés | MEDLINE | ID: mdl-29528450

RESUMEN

BACKGROUND: Malignant pleural effusion is a commonly seen complication of malignancies such as lung and breast cancers. In Western countries, talc is frequently used as a standard therapeutic agent (pleurodesis agent) with the aim of alleviating symptoms including dyspnea and chest pain. Talc is not recognized as a pleurodesis agent in Japan. The aim of this study was to verify the efficacy and safety of sterilized talc (NPC-05) for the introduction of talc in Japan. METHODS: The study was a single-arm, open-label, investigator-initiated trial conducted jointly at six institutions. The subjects were 30 patients with malignant pleural effusions. A solution of 4 g NPC-05 suspended in 50 ml physiological saline was instilled into the pleural space to perform pleurodesis. RESULTS: The efficacy of NPC-05 for pleural adhesion 30 days after pleurodesis was 83.3% (25/30 cases). Amelioration of dyspnea and pain (chest pain) was seen. Commonly seen adverse effects were increased C-reactive protein (CRP) and fever. Nearly all adverse events were phenomena previously reported as adverse effects of talc. No acute respiratory distress syndrome (ARDS) or other serious side effects occurred. CONCLUSION: The efficacy and safety of NPC-05 for malignant pleural effusion in Japanese patients was verified, and the clinical outcomes with talc were confirmed to be the same as previously reported in other countries. There is thought to be a high level of need for this agent in the treatment of malignant pleural effusion in Japan.


Asunto(s)
Aplicación de Nuevas Drogas en Investigación , Derrame Pleural Maligno/terapia , Pleurodesia , Esterilización , Talco/uso terapéutico , Adulto , Anciano , Determinación de Punto Final , Femenino , Humanos , Japón , Masculino , Persona de Mediana Edad , Pleurodesia/efectos adversos , Talco/efectos adversos , Resultado del Tratamiento
6.
Respiration ; 95(6): 465-468, 2018.
Artículo en Inglés | MEDLINE | ID: mdl-29680830

RESUMEN

Stenting at the flow-limiting segment can improve the ventilation-perfusion ratio in patients with central airway stenosis. However, there is no quantitative examination for assessing the perfusion status during interventional bronchoscopy. Intrabronchial capnography can estimate regional gas exchange by measuring carbon dioxide concentration. We herein report a case of bilateral bronchial stenosis where stenting was able to improve ventilation-perfusion ratio using intrabronchial capnography. A 44-year-old man was admitted to our institution with orthopnea. Chest computed tomography showed an extrinsic compression at the bilateral main bronchus and right pulmonary artery due to a mediastinal mass. After introduction of general anesthesia, arterial oxygen tension suddenly decreased in the supine position. After initial stenting, an increase was seen in ventilation at the right lung; however, a ventilation-perfusion mismatch occurred due to an increase in dead-space ventilation at the right pulmonary artery stenosis. Intrabronchial capnography was an effective modality to confirm the regional perfusion status during interventional bronchoscopy in real time.


Asunto(s)
Enfermedades Bronquiales/complicaciones , Estenosis de Arteria Pulmonar/diagnóstico , Adulto , Broncoscopía , Capnografía , Humanos , Masculino , Circulación Pulmonar , Estenosis de Arteria Pulmonar/complicaciones , Estenosis de Arteria Pulmonar/fisiopatología
7.
Respiration ; 95(2): 106-113, 2018.
Artículo en Inglés | MEDLINE | ID: mdl-29190612

RESUMEN

BACKGROUND: In patients with bronchial obstruction estimating the location of the maximal obstruction is crucial for guiding interventional bronchoscopy. However, flow-volume curves cannot discriminate between the right and left lungs. OBJECTIVES: The aim of this study was to physiologically evaluate bronchial obstruction during interventional bronchoscopy. METHODS: We prospectively measured lateral airway pressure (Plat) at either side of the obstruction using a double-lumen catheter (pressure-pressure [P-P] curve) simultaneously to assess the degree of bronchial obstruction in 22 patients. The shape of the P-P curve was assessed to confirm the site of maximal obstruction. RESULTS: In the experimental study, Plat was uniform between both bronchi in the normal model. For the unilateral and bilateral obstruction models, a phase shift was only seen for the more obstructed side. In healthy subjects, the angle of the P-P curve was close to 45° and linear in shape. In patients with bronchial obstruction, the angle was much smaller but approached 45° after the bronchoscopic procedure. The degree of bronchial obstruction was significantly correlated with the angle of the P-P curve (r = -0.51, p < 0.01). Dyspnea significantly increased when the airway lumen was obstructed by more than 60% (p < 0.0001), and when the P-P curve appeared loop-shaped (p < 0.01). CONCLUSIONS: The shape of the P-P curve could be used to detect the site of maximal obstruction for the optimal positioning of the stent and assess the need for additional procedures in real time in patients with bronchial obstruction.


Asunto(s)
Obstrucción de las Vías Aéreas/diagnóstico , Enfermedades Bronquiales/diagnóstico , Broncoscopía/métodos , Adulto , Anciano , Anciano de 80 o más Años , Estudios de Factibilidad , Femenino , Humanos , Masculino , Persona de Mediana Edad , Presión
8.
Respiration ; 92(4): 252-257, 2016.
Artículo en Inglés | MEDLINE | ID: mdl-27626282

RESUMEN

BACKGROUND: Regional lung sound distribution in chronic obstructive pulmonary disease (COPD) is reported to be asynchronous. Mathematical analyses using vibration response imaging (VRI), such as left and right lung asynchrony (gap index; GI) and regional lung asynchrony (asynchrony score; AS), are useful measures to evaluate lung sound asynchrony. OBJECTIVES: The aim of this study was to investigate the association of lung sound asynchrony with pulmonary functions and emphysematous lesions in COPD patients. METHODS: VRI recordings and pulmonary function tests were performed in 46 stable male COPD patients and in 40 healthy male smokers. Lung sound asynchrony was evaluated using GI, AS of the left and right lung (AS L-R), and AS of the upper and lower lung (AS U-L). In 38 patients, computed tomography taken within 6 months was available and analyzed. RESULTS: AS L-R and AS U-L were significantly higher in COPD patients than in healthy smokers, with no significant difference in GI. There were no significant correlations with either AS and pulmonary functions, excluding a negative correlation between AS U-L and diffusion capacity. Although there were no significant correlations between both AS and severity of emphysema, significant positive correlations were observed between heterogeneity of emphysematous lesions and AS L-R (ρ = 0.38, p < 0.05) or AS U-L (ρ = 0.51, p < 0.005). CONCLUSIONS: Regional lung sounds are distributed more asynchronously in COPD patients than in healthy smokers, which correlates with the heterogeneous distribution of emphysematous lesions.


Asunto(s)
Pulmón/fisiopatología , Enfermedad Pulmonar Obstructiva Crónica/fisiopatología , Enfisema Pulmonar/fisiopatología , Ruidos Respiratorios/fisiopatología , Adulto , Anciano , Anciano de 80 o más Años , Estudios de Casos y Controles , Volumen Espiratorio Forzado , Humanos , Pulmón/diagnóstico por imagen , Masculino , Flujo Espiratorio Máximo , Persona de Mediana Edad , Tomografía Computarizada Multidetector , Enfermedad Pulmonar Obstructiva Crónica/diagnóstico por imagen , Enfisema Pulmonar/diagnóstico por imagen , Pruebas de Función Respiratoria , Índice de Severidad de la Enfermedad , Capacidad Vital , Adulto Joven
9.
Am J Respir Crit Care Med ; 192(4): 468-76, 2015 Aug 15.
Artículo en Inglés | MEDLINE | ID: mdl-26039792

RESUMEN

RATIONALE: The combination of an ultrathin bronchoscope, navigational technology, and endobronchial ultrasound (EBUS) seems to combine the best of mutual abilities for evaluating peripheral pulmonary lesions, but ultrathin bronchoscopes that allow the use of EBUS have not been developed so far. OBJECTIVES: To compare the diagnostic yield of transbronchial biopsy under EBUS, fluoroscopy, and virtual bronchoscopic navigation guidance using a novel ultrathin bronchoscope with that using a thin bronchoscope with a guide sheath for peripheral pulmonary lesions. METHODS: In four centers, patients with suspected peripheral pulmonary lesions less than or equal to 30 mm in the longest diameter were included and randomized to undergo transbronchial biopsy with EBUS, fluoroscopy, and virtual bronchoscopic navigation guidance using a 3.0-mm ultrathin bronchoscope (UTB group) or a 4.0-mm thin bronchoscope with a guide sheath (TB-GS group). MEASUREMENTS AND MAIN RESULTS: A total of 310 patients were enrolled and randomized, among whom 305 patients (150, UTB group; 155, TB-GS group) were analyzed. The ultrathin bronchoscope could reach more distal bronchi than the thin bronchoscope (median fifth- vs. fourth-generation bronchi; P < 0.001). Diagnostic histologic specimens were obtained in 74% (42% for benign and 81% for malignant lesions) of the UTB group and 59% (36% for benign and 70% for malignant lesions) of the TB-GS group (P = 0.044, Mantel-Haenszel test). Complications including pneumothorax, bleeding, chest pain, and pneumonia occurred in 3% and 5% in the respective groups. CONCLUSIONS: The diagnostic yield of the UTB method is higher than that of the TB-GS method. Clinical trial registered with www.umin.ac.jp/ctr/ (UMIN 000003177).


Asunto(s)
Broncoscopios , Broncoscopía/instrumentación , Endosonografía/instrumentación , Biopsia Guiada por Imagen/instrumentación , Neoplasias Pulmonares/patología , Imagen Multimodal/instrumentación , Adulto , Anciano , Anciano de 80 o más Años , Diseño de Equipo , Femenino , Fluoroscopía/instrumentación , Humanos , Masculino , Persona de Mediana Edad
10.
Nihon Rinsho ; 74(5): 807-12, 2016 May.
Artículo en Japonés | MEDLINE | ID: mdl-27254951

RESUMEN

Several non-surgical and minimally invasive bronchoscopic interventions, such as bronchoscopic lung volume reduction (BLVR) techniques, have been developed to treat patients with severe chronic obstructive pulmonary disease (COPD). BLVR has been studied for treatment in severe COPD patients with emphysema. BLVR with one-way endobronchial valves is reported to be effective for patients with a heterogeneous emphysema distribution and without inter-lobar collateral ventilation. For the patients with collateral ventilation, and for the patients with homogeneous emphysema, BLVR with lung volume reduction coil has shown promising results. Targeted lung denervation(TLD) is a novel bronchoscopic intervention based on ablation of parasympathetic nerves surrounding the main bronchi. TLD seems to be effective for COPD with chronic bronchitis phenotype. This review gives a general overview of BLVR with one-way valve and lung volume reduction coil, and TLD.


Asunto(s)
Broncoscopía/métodos , Neumonectomía/métodos , Enfermedad Pulmonar Obstructiva Crónica/cirugía , Desnervación/métodos , Humanos , Pulmón/inervación , Enfermedad Pulmonar Obstructiva Crónica/complicaciones , Enfisema Pulmonar/etiología , Enfisema Pulmonar/cirugía
11.
Respiration ; 89(2): 148-54, 2015.
Artículo en Inglés | MEDLINE | ID: mdl-25613475

RESUMEN

BACKGROUND: Endobronchial ultrasonography using a guide sheath (EBUS-GS) is an increasingly common bronchoscopic technique, but currently, no methods have been established to quantitatively evaluate EBUS images of peripheral pulmonary lesions. OBJECTIVES: The purpose of this study was to evaluate whether histogram data collected from EBUS-GS images can contribute to the diagnosis of lung cancer. METHODS: Histogram-based analyses focusing on the brightness of EBUS images were retrospectively conducted: 60 patients (38 lung cancer; 22 inflammatory diseases), with clear EBUS images were included. For each patient, a 400-pixel region of interest was selected, typically located at a 3- to 5-mm radius from the probe, from recorded EBUS images during bronchoscopy. Histogram height, width, height/width ratio, standard deviation, kurtosis and skewness were investigated as diagnostic indicators. RESULTS: Median histogram height, width, height/width ratio and standard deviation were significantly different between lung cancer and benign lesions (all p < 0.01). With a cutoff value for standard deviation of 10.5, lung cancer could be diagnosed with an accuracy of 81.7%. Other characteristics investigated were inferior when compared to histogram standard deviation. CONCLUSIONS: Histogram standard deviation appears to be the most useful characteristic for diagnosing lung cancer using EBUS images.


Asunto(s)
Adenocarcinoma/diagnóstico por imagen , Carcinoma de Células Escamosas/diagnóstico por imagen , Neoplasias Pulmonares/diagnóstico por imagen , Adenocarcinoma/patología , Broncoscopía , Carcinoma de Células Escamosas/patología , Humanos , Procesamiento de Imagen Asistido por Computador , Neoplasias Pulmonares/patología , Estudios Retrospectivos , Carcinoma Pulmonar de Células Pequeñas/diagnóstico por imagen , Carcinoma Pulmonar de Células Pequeñas/patología , Ultrasonografía Intervencional
12.
Respiration ; 90(6): 468-73, 2015.
Artículo en Inglés | MEDLINE | ID: mdl-26509473

RESUMEN

BACKGROUND: Although tracheal stenosis occurs in relapsing polychondritis (RP), no studies exist that have clarified correlations between quantitative airway measurement and spirometry in RP patients. OBJECTIVES: The aim of this study was to investigate correlations between the cross-sectional area (CSA) of the trachea and spirometric values in patients with RP. METHODS: The institutional review board approved this retrospective study, and written informed consent was waived. Twenty-six patients with RP underwent spirometry and chest computed tomography (CT) at full inspiration and end-expiration. On inspiratory and expiratory chest CT images, CSA at the intrathoracic trachea was measured for all CT slices, and the mean and minimum tracheal CSA were obtained. Correlations between the tracheal CSA and spirometric values were assessed by Spearman's rank correlation analysis. Results: Tracheal CSA measurements for inspiratory and expiratory scans were significantly correlated with FEV 1 , FEV 25-75% , and peak flow values (ρ = 0.51-0.86, p <0.01). During each inspiratory or expiratory phase, the minimum tracheal CSA achieved a higher correlation coefficient with spirometric values than the mean CSA. CONCLUSION: Tracheal dimensions for both inspiratory and expiratory CT are significant predictors of pulmonary function in patients with RP. The narrowest tracheal dimension likely determines the severity of airflow limitation in RP.


Asunto(s)
Policondritis Recurrente/fisiopatología , Espirometría , Tráquea/diagnóstico por imagen , Adulto , Anciano , Anciano de 80 o más Años , Espiración/fisiología , Femenino , Flujo Espiratorio Forzado/fisiología , Volumen Espiratorio Forzado/fisiología , Humanos , Inhalación/fisiología , Masculino , Persona de Mediana Edad , Tomografía Computarizada Multidetector , Estudios Retrospectivos , Adulto Joven
13.
J Comput Assist Tomogr ; 38(6): 968-71, 2014.
Artículo en Inglés | MEDLINE | ID: mdl-25007341

RESUMEN

OBJECTIVE: The purpose of this study was to evaluate the relationship between quantitative computed tomography (CT) parameters of air trapping obtained with inspiratory and expiratory CT and pulmonary function tests (PFTs) in patients with relapsing polychondritis (RP). MATERIALS AND METHODS: This study included 23 patients with RP who underwent both CT and PFTs. In each patient, the mean lung density (MLD) was obtained by averaging CT attenuation of the lung parenchyma on both inspiratory and expiratory CT. The ratio of expiratory MLD to inspiratory MLD (E/I ratio) was also calculated. Correlations between those quantitative CT measurements and the results of PFTs were evaluated using Spearman rank correlation. RESULTS: The expiratory MLD and E/I ratio were significantly correlated with forced expiratory volume in 1 second (FEV1) %predicted, ratio of FEV1 to FVC (FEV1/FVC), and the mid expiratory phase of forced expiratory flow (FEF25%-75%) %predicted (expiratory MLD: FEV1 %predicted, r = 0.764, P < 0.0001; FEV1/FVC, r = 0.764, P < 0.0001; FEF25%-75% %predicted, r = 0.674, P < 0.001, respectively; the E/I ratio: FEV1 %predicted, r = -0.689, P < 0.001; FEV1/FVC, r = -0.689, P < 0.001; FEF25%-75% %predicted, r = -0.586, P < 0.01, respectively). The correlation between inspiratory MLD and PFTs did not reach statistical significance. CONCLUSIONS: In RP patients, air trapping demonstrated on expiratory CT correlated with airway obstruction. This study may assist further refinement of the use of CT as quantitative evaluation for small and large airway obstruction in RP.


Asunto(s)
Aire , Policondritis Recurrente/diagnóstico por imagen , Policondritis Recurrente/fisiopatología , Tomografía Computarizada por Rayos X/métodos , Adolescente , Adulto , Anciano , Espiración , Femenino , Humanos , Inhalación , Masculino , Persona de Mediana Edad , Pruebas de Función Respiratoria , Estudios Retrospectivos , Espirometría , Adulto Joven
14.
Respiration ; 87(1): 45-53, 2014.
Artículo en Inglés | MEDLINE | ID: mdl-23860295

RESUMEN

BACKGROUND: Bronchodilators have been reported to influence regional lung ventilation in patients with chronic obstructive pulmonary disease (COPD), which may change regional lung sound distribution. Vibration response imaging (VRI) is a lung imaging system for the assessment of breath sounds. OBJECTIVE: To evaluate the effects of a short-acting ß2-agonist (SABA) on the regional distribution of lung sounds in COPD patients. METHODS: A double-blind crossover trial was performed to compare the treatment of COPD patients with an SABA (20 µg of inhaled procaterol) versus a placebo. The percentage of regional lung sound energy [quantitative lung data (QLD)] was evaluated with VRI. VRI, spirometry, and impulse oscillometry (IOS) were performed immediately before and 30 min after SABA administration. RESULTS: Ten male patients (69.6 ± 14.2 years of age, percentage predicted forced expiratory volume in 1 s: 43.8 ± 16.9%) were evaluated. The use of an SABA produced significant functional improvements in the spirometric and IOS measurements. Among the homogeneous emphysema patients (n = 7), the upper-lung QLD decreased (from 24.2 ± 5.8 to 18.8 ± 6.1%, p < 0.05) and the lower-lung QLD increased (from 37.9 ± 12.7 to 46.1 ± 14.3%, p < 0.05) following SABA inhalation. However, the significant redistribution of the regional lung QLD to the lower-lung field was not observed in 2 of the 3 inhomogeneous emphysema patients. CONCLUSION: The additional use of an SABA by COPD patients improved their pulmonary function, which was accompanied by changes in regional lung air flow. The distribution of emphysematous lesions and the bronchial reactivity to SABA appeared to affect the redistribution of the lung sounds following bronchodilator administration.


Asunto(s)
Broncodilatadores/uso terapéutico , Pulmón/fisiopatología , Enfermedad Pulmonar Obstructiva Crónica/tratamiento farmacológico , Ruidos Respiratorios/fisiopatología , Adulto , Anciano , Anciano de 80 o más Años , Albuterol/análogos & derivados , Albuterol/uso terapéutico , Estudios Cruzados , Método Doble Ciego , Femenino , Humanos , Pulmón/diagnóstico por imagen , Masculino , Persona de Mediana Edad , Enfermedad Pulmonar Obstructiva Crónica/diagnóstico por imagen , Enfermedad Pulmonar Obstructiva Crónica/fisiopatología , Xinafoato de Salmeterol , Derivados de Escopolamina/uso terapéutico , Teofilina/uso terapéutico , Bromuro de Tiotropio , Tomografía Computarizada por Rayos X , Vibración
15.
Mod Rheumatol ; 24(1): 129-36, 2014 Jan.
Artículo en Inglés | MEDLINE | ID: mdl-24261769

RESUMEN

OBJECTIVES: We aimed to identify a serum biomarker for evaluating the disease activity of relapsing polychondritis (RP). METHODS: We measured and compared serum levels of 28 biomarkers potentially associated with this disease, including soluble triggering receptor expressed on myeloid cells-1 (sTREM-1), high-sensitivity C-reactive protein (hs-CRP), and cartilage oligomeric matrix protein (COMP), in 15 RP patients and 16 healthy donors (HDs). We divided the 15 RP patients into active RP (n = 8) and inactive RP (n = 7) groups, depending on the extent of the disease, and compared candidate markers between groups. The localization of membrane-bound TREM-1 in the affected tissue was examined by immunohistochemistry. RESULTS: Serum levels of sTREM-1, interferon-γ, chemokine (C-C motif) ligand 4, vascular endothelial growth factor, and matrix metalloproteinases-3 were significantly higher in RP patients than HDs. Among these markers, sTREM-1 had the highest sensitivity and specificity (86.7 and 86.7 %, respectively). Furthermore, the serum level of sTREM-1 was significantly higher in active RP patients than inactive RP patients (p = 0.0403), but this was not true for hs-CRP or COMP. TREM-1 was expressed on endothelial cells in RP lesions. CONCLUSIONS: The serum level of sTREM-1 may be a useful marker of disease activity in RP.


Asunto(s)
Glicoproteínas de Membrana/sangre , Policondritis Recurrente/sangre , Receptores Inmunológicos/sangre , Adolescente , Adulto , Anciano , Anciano de 80 o más Años , Biomarcadores/sangre , Niño , Femenino , Humanos , Masculino , Persona de Mediana Edad , Índice de Severidad de la Enfermedad , Receptor Activador Expresado en Células Mieloides 1
16.
Arerugi ; 63(10): 1338-47, 2014 Dec.
Artículo en Japonés | MEDLINE | ID: mdl-25634459

RESUMEN

BACKGROUND: The efficacy of anti-IgE antibody, omalizumab, was studied in patients with severe bronchial asthma. There have been reports stating that although omalizumab could not improve objective results, it has shown improvements in subjective symptoms of patients. The aim of this study is to evaluate the efficacy of omalizumab in severe bronchial asthma. METHODS: Thirteen patients were enrolled. Omalizumab was administered subcutaneously every 2 or 4 weeks based on serum IgE level and body weight of each patient. Pulmonary function tests, Asthma Control Test (ACT), Asthma Health Questionnaire-JAPAN (AHQ-JAPAN), number of emergency visits and dosage of methylprednisolone during a 16-week period were compared to the previous year. We examined the correlations between respiratory function, and ACT and AHQ-JAPAN. RESULTS: Treatment with omalizumab did not improve lung function. AHQ and ACT over the 16-week period significantly improved compared to baseline (p<0.01). The number of emergency visit and doses of methylprednisolone were significantly reduced compared to the previous year (p<0.01). CONCLUSION: Although treatment with omalizumab could not improve lung function, AHQ and ACT during the 16-week study period had significantly improved compared to baseline. Omalizumab significantly reduced the number of emergency visits and dosages of methylprednisolone.


Asunto(s)
Antiasmáticos/uso terapéutico , Anticuerpos Antiidiotipos/uso terapéutico , Anticuerpos Monoclonales Humanizados/uso terapéutico , Asma/tratamiento farmacológico , Adulto , Anciano , Anciano de 80 o más Años , Asma/fisiopatología , Progresión de la Enfermedad , Femenino , Humanos , Masculino , Persona de Mediana Edad , Omalizumab , Encuestas y Cuestionarios , Adulto Joven
17.
Am J Respir Crit Care Med ; 185(1): 24-33, 2012 Jan 01.
Artículo en Inglés | MEDLINE | ID: mdl-21997334

RESUMEN

RATIONALE: Lateral airway pressure can provide valuable physiological information during bronchoscopy. OBJECTIVES: To evaluate tracheal obstruction during intervention. METHODS: To prospectively measure lateral airway pressure during bronchoscopy using a double-lumen catheter in 15 healthy subjects and 30 patients with tracheal obstruction. Pressure difference was used to evaluate the site of maximal obstruction. The angle between pressure recordings on either side of the stenosis was measured simultaneously (pressure-pressure curves) to assess the degree of tracheal obstruction. MEASUREMENTS AND MAIN RESULTS: In the experimental study, the angle of the pressure-pressure curve was unaffected by breathing maneuvers whereas the pressure difference was affected. In healthy subjects, no pressure difference between the carina and trachea was observed during tidal breathing, and the angle was close to 45°. In patients with tracheal obstruction, the dyspnea scale, pressure difference, and angle changed significantly beyond 50% obstruction (P<0.0001). After stenting, the pressure difference disappeared and the angle was close to 45°. The degree of tracheal obstruction was significantly correlated with the pressure difference (r=0.83, P<0.0001) and angle (r=-0.84, P<0.0001). The cross-sectional area, dyspnea scale, pulmonary function tests, pressure difference, and the angle significantly improved after procedures (P<0.0001). Responder rates on the modified Medical Research Council Scale were 84.6% for obstructions above 80%, and 58.8% for obstructions between 50 and 80%. CONCLUSIONS: The direct measurement of pressure difference and the angle of the pressure-pressure curve represent a new assessment modality for the success of interventional bronchoscopy. Measuring lateral airway pressure could estimate the need for additional procedures better than bronchoscopy alone.


Asunto(s)
Obstrucción de las Vías Aéreas/diagnóstico por imagen , Broncoscopía/métodos , Respiración , Tráquea/diagnóstico por imagen , Estenosis Traqueal/diagnóstico por imagen , Adulto , Anciano , Anciano de 80 o más Años , Estudios de Factibilidad , Femenino , Humanos , Masculino , Persona de Mediana Edad , Presión , Estudios Prospectivos , Curva ROC , Pruebas de Función Respiratoria , Tomografía Computarizada por Rayos X
18.
Respir Care ; 57(4): 634-41, 2012 Apr.
Artículo en Inglés | MEDLINE | ID: mdl-22005343

RESUMEN

Choke points and airway wall structure in expiratory central airway collapse are poorly defined. Computed tomography, white light bronchoscopy, endobronchial ultrasound, vibration response imaging, spirometry, impulse oscillometry, negative expiratory pressure, and intraluminal catheter airway pressure measurements were used in a patient with cough, dyspnea, and recurrent pulmonary infections. Computed tomography and white light bronchoscopy identified dynamic collapse of the trachea and mainstem bronchi, consistent with severe crescent tracheobronchomalacia. Spirometry showed severe obstruction. Endobronchial ultrasound revealed collapse of the airway cartilage, and vibration response imaging revealed fluttering at both lung zones. Impulse oscillometry and negative expiratory pressure suggested tidal expiratory flow limitation in the intrathoracic airways. Intraluminal catheter airway pressure measurements identified the choke point in the lower trachea. After Y-stent insertion, the choke point migrated distally. Imaging studies revealed improved airway dynamics, airway patency, and ventilatory function. Novel imaging and physiologic assessments could be used to localize choke points and airway wall structure in tracheobronchomalacia.


Asunto(s)
Obstrucción de las Vías Aéreas/diagnóstico , Diagnóstico por Imagen/métodos , Atelectasia Pulmonar/fisiopatología , Traqueobroncomalacia/diagnóstico , Anciano , Obstrucción de las Vías Aéreas/fisiopatología , Bronquios/diagnóstico por imagen , Broncoscopía , Constricción Patológica , Endosonografía , Humanos , Masculino , Oscilometría , Atelectasia Pulmonar/diagnóstico , Espirometría , Stents , Traqueobroncomalacia/fisiopatología , Vibración
19.
Jpn J Clin Oncol ; 41(10): 1177-81, 2011 Oct.
Artículo en Inglés | MEDLINE | ID: mdl-21865219

RESUMEN

BACKGROUND: Endobronchial ultrasonography (EBUS) has been used in diagnosing peripheral lung cancer and has allowed for higher rates of peripheral lung cancer diagnosis. However, no studies have reported that fluoroscopy time is shortened by the use of endobronchial ultrasonography. We aimed to investigate whether fluoroscopy time is shortened using endobronchial ultrasonography. METHODS: We retrospectively researched fluoroscopy time in terms of the rate of diagnosis, lesion size, age, gender, histologic type and lesion site in 147 cases of malignant lesions from January 2006 to September 2007 at the Tokai University Hospital. The location of the bronchial brush or biopsy forceps was confirmed by fluoroscopy without endobronchial ultrasonography with guide-sheath group in 96 of the 147 cases, while fluoroscopy with endobronchial ultrasonography guide sheath group was confirmed in 51 cases. RESULTS: The result was that fluoroscopy time was significantly shortened in the endobronchial ultrasonography guide-sheath group (4.08 ± 3.27 min) compared with the non-endobronchial ultrasonography guide-sheath group (7.06 ± 3.99 min), but there was no significant difference between either groups in terms of bronchoscopic diagnosis, lesion size, age, gender, histologic type and lesion site. CONCLUSION: The use of endobronchial ultrasonography guide sheath allows a reduction in fluoroscopy time and may reduce the adverse effects of radiation exposure on patients and staff.


Asunto(s)
Bronquios/diagnóstico por imagen , Endosonografía , Fluoroscopía , Neoplasias Pulmonares/diagnóstico por imagen , Anciano , Endosonografía/instrumentación , Femenino , Fluoroscopía/instrumentación , Humanos , Neoplasias Pulmonares/patología , Masculino , Estudios Retrospectivos , Factores de Tiempo
20.
Respir Investig ; 59(2): 235-239, 2021 Mar.
Artículo en Inglés | MEDLINE | ID: mdl-33187889

RESUMEN

BACKGROUND: Endobronchial ultrasound-guided transbronchial needle aspiration (EBUS-TBNA) is a minimally invasive hilar mediastinal node sampling technique used for lung cancer staging and diagnosis of lesions. Besides the conventional 22-gauge (G) and 21G needles, a 25G needle is now available for this procedure. The objective of this study was to evaluate the efficacy of the 25G EBUS-TBNA needle. METHODS: We retrospectively reviewed consecutive patients who underwent EBUS-TBNA using both 22G and 25G aspiration needles from January 2017 through December 2017 at St. Marianna University School of Medicine. We identified 10 patients and compared the diagnostic yield and the sample volume for each needle. RESULTS: Six patients were diagnosed with lung cancer and four with sarcoidosis. Total diagnostic yield was 80% (8/10) for the 22G and 60% (6/10) for the 25G (P = 0.31). In patients with lung cancer, the diagnostic yield was 67% (4/6) for the 22G and 83% (5/6) for the 25G (P = 0.50). In patients with sarcoidosis, the diagnostic yield was 100% (4/4) for the 22G and 25% (1/4) for the 25G (P = 0.07). In patients with lung cancer, the median tissue area was comparable for each needle; however, in patients with sarcoidosis, the sample area was smaller for the 25G than for the 22G. We did not encounter any major complications or bleeding during EBUS-TBNA procedures. CONCLUSIONS: Although histologic specimens obtained by the 25G needle are expected to be useful for the diagnosis of lung cancer, we found the 25G needle inadequate for diagnosing sarcoidosis due to insufficient sample size.


Asunto(s)
Biopsia por Aspiración con Aguja Fina Guiada por Ultrasonido Endoscópico/instrumentación , Neoplasias Pulmonares/diagnóstico , Neoplasias Pulmonares/patología , Pulmón/patología , Agujas , Manejo de Especímenes/métodos , Adulto , Anciano , Biopsia por Aspiración con Aguja Fina Guiada por Ultrasonido Endoscópico/métodos , Femenino , Humanos , Neoplasias Pulmonares/complicaciones , Masculino , Persona de Mediana Edad , Estudios Retrospectivos , Sarcoidosis Pulmonar/complicaciones
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA