Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 178
Filtrar
Más filtros

Bases de datos
País/Región como asunto
Tipo del documento
País de afiliación
Intervalo de año de publicación
1.
Circ J ; 86(5): 857-865, 2022 04 25.
Artículo en Inglés | MEDLINE | ID: mdl-35197394

RESUMEN

BACKGROUND: This study aimed to quantitatively evaluate myocardial perfusion single-photon emission computed tomography (SPECT) using an original analysis tool in the compartment model for detecting regional significant coronary artery disease (CAD).Methods and Results: This study analyzed 41 patients (median age, 76 years) with suspected or known CAD who underwent both dynamic SPECT using 99 mTc-tetrofosmin and invasive coronary angiography. The quantitative analysis was performed using a single-tissue compartment model to evaluate the diagnostic performance of the myocardial flow reserve (MFR) for regional significant CAD, excluding infarcted territories. In the regional analysis, 114 vessels were assessed, of which 31 were diagnosed as significant coronary lesions (≥70% stenosis and/or fraction flow reserve ≤0.8). The MFR of regional significant CAD was significantly lower than that of non-significant CAD (1.11 [0.97-1.31] vs. 1.74 [1.30-2.27]; P<0.001). In the receiver operating characteristic curve analysis, the MFR displayed an area under the curve (AUC) of 0.81. While analyzing each coronary artery territory, the diagnostic performance of the MFR value in the left anterior descending (LAD) artery territory was found to be significantly higher than that found in qualitative assessment (AUC: 0.84 vs. 0.61). CONCLUSIONS: A quantitative analysis of dynamic SPECT data facilitated detecting regional CAD. For the LAD artery, the MFR displayed a higher diagnostic performance than the qualitative assessment of conventional myocardial perfusion SPECT.


Asunto(s)
Enfermedad de la Arteria Coronaria , Imagen de Perfusión Miocárdica , Anciano , Angiografía Coronaria/métodos , Enfermedad de la Arteria Coronaria/diagnóstico por imagen , Humanos , Imagen de Perfusión Miocárdica/métodos , Perfusión , Curva ROC , Tomografía Computarizada de Emisión de Fotón Único/métodos
2.
Heart Vessels ; 37(1): 31-39, 2022 Jan.
Artículo en Inglés | MEDLINE | ID: mdl-34232385

RESUMEN

Computed tomography (CT)-derived three-dimensional maximum principal strain (MP-strain) can provide incremental value to coronary CT angiography for cardiac dysfunction assessment with high diagnostic performance in patients with myocardial infarction. Global longitudinal strain (GLS) measured using two-dimensional speckle tracking echocardiography (2D-STE) is more sensitive than left ventricular ejection fraction (LVEF) for detecting early myocardial dysfunction. We aimed to compare CT-derived MP-strain with each of 2D-STE-derived strains (i.e., longitudinal, circumferential, and radial strains), and identify the major determinants of CT-derived MP-strain among 2D-STE-derived strains. We studied 51 patients who underwent cardiac CT and echocardiography. CT images were reconstructed at every 5% (0-95%) of the RR interval. A dedicated workstation was used to analyze CT-derived MP-strain on the 16-segment model. We calculated CT-derived global MP-strain with all the 16 segments on a per patient basis. Pearson's test was used to assess correlations between CT-derived MP-strain and STE-strain at global and segmental levels. The intra-class correlation coefficient for interobserver agreement for CT-derived global MP-strain was 0.98 (95% confidence interval 0.96-0.99). The low-CT-derived global MP-strain group (≤ 0.43) had more patients with LV dysfunction than the high-CT-derived global MP-strain group (> 0.43). CT-derived global MP-strain was associated with STE-GLS (r = 0.738, P < 0.001), global circumferential strain (r = 0.646, P < 0.001), and global radial strain (r = 0.432, P = 0.001). In multivariate analysis, STE-GLS had the strongest association to CT-derived global MP-strain among three directional STE-strains and LVEF by echocardiography (standardized coefficient = - 0.527, P < 0.001). STE-GLS is a major determinant of CT-derived global MP-strain. CT-derived MP-strain may enhance the value of coronary CT angiography by adding functional information to CT-derived LVEF.


Asunto(s)
Ecocardiografía Tridimensional , Disfunción Ventricular Izquierda , Función Ventricular Izquierda , Ecocardiografía , Ventrículos Cardíacos/diagnóstico por imagen , Humanos , Reproducibilidad de los Resultados , Volumen Sistólico , Tomografía Computarizada por Rayos X , Disfunción Ventricular Izquierda/diagnóstico por imagen
3.
J Magn Reson Imaging ; 53(2): 381-391, 2021 02.
Artículo en Inglés | MEDLINE | ID: mdl-32914921

RESUMEN

BACKGROUND: The addition of synthetic MRI might improve the diagnostic performance of dynamic contrast-enhanced MRI (DCE-MRI) in patients with breast cancer. PURPOSE: To evaluate the diagnostic value of a combination of DCE-MRI and quantitative evaluation using synthetic MRI for differentiation between benign and malignant breast masses. STUDY TYPE: Retrospective, observational. POPULATION: In all, 121 patients with 131 breast masses who underwent DCE-MRI with additional synthetic MRI were enrolled. FIELD STRENGTH/SEQUENCE: 3.0 Tesla, T1 -weighted DCE-MRI and synthetic MRI acquired by a multiple-dynamic, multiple-echo sequence. ASSESSMENT: All lesions were differentiated as benign or malignant using the following three diagnostic methods: DCE-MRI type based on the Breast Imaging-Reporting and Data System; synthetic MRI type using quantitative evaluation values calculated by synthetic MRI; and a combination of the DCE-MRI + Synthetic MRI types. The diagnostic performance of the three methods were compared. STATISTICAL TESTS: Univariate (Mann-Whitney U-test) and multivariate (binomial logistic regression) analyses were performed, followed by receiver-operating characteristic curve (AUC) analysis. RESULTS: Univariate and multivariate analyses showed that the mean T1 relaxation time in a breast mass obtained by synthetic MRI prior to injection of contrast agent (pre-T1 ) was the only significant quantitative value acquired by synthetic MRI that could independently differentiate between malignant and benign breast masses. The AUC for all enrolled breast masses assessed by DCE-MRI + Synthetic MRI type (0.83) was significantly greater than that for the DCE-MRI type (0.70, P < 0.05) or synthetic MRI type (0.73, P < 0.05). The AUC for category 4 masses assessed by the DCE-MRI + Synthetic MRI type was significantly greater than that for those assessed by the DCE-MRI type (0.74 vs. 0.50, P < 0.05). DATA CONCLUSION: A combination of synthetic MRI and DCE-MRI improves the accuracy of diagnosis of benign and malignant breast masses, especially category 4 masses. Level of Evidence 4 Technical Efficacy Stage 2 J. MAGN. RESON. IMAGING 2021;53:381-391.


Asunto(s)
Neoplasias de la Mama , Medios de Contraste , Mama/diagnóstico por imagen , Neoplasias de la Mama/diagnóstico por imagen , Diagnóstico Diferencial , Humanos , Imagen por Resonancia Magnética , Estudios Retrospectivos
4.
J Cardiovasc Magn Reson ; 23(1): 10, 2021 02 22.
Artículo en Inglés | MEDLINE | ID: mdl-33618722

RESUMEN

BACKGROUND: Feature tracking (FT) has become an established tool for cardiovascular magnetic resonance (CMR)-based strain analysis. Recently, the compressed sensing (CS) technique has been applied to cine CMR, which has drastically reduced its acquisition time. However, the effects of CS imaging on FT strain analysis need to be carefully studied. This study aimed to investigate the use of CS cine CMR for FT strain analysis compared to conventional cine CMR. METHODS: Sixty-five patients with different left ventricular (LV) pathologies underwent both retrospective conventional cine CMR and prospective CS cine CMR using a prototype sequence with the comparable temporal and spatial resolution at 3 T. Eight short-axis cine images covering the entire LV were obtained and used for LV volume assessment and FT strain analysis. Prospective CS cine CMR data over 1.5 heartbeats were acquired to capture the complete end-diastolic data between the first and second heartbeats. LV volume assessment and FT strain analysis were performed using a dedicated software (ci42; Circle Cardiovasacular Imaging, Calgary, Canada), and the global circumferential strain (GCS) and GCS rate were calculated from both cine CMR sequences. RESULTS: There were no significant differences in the GCS (- 17.1% [- 11.7, - 19.5] vs. - 16.1% [- 11.9, - 19.3; p = 0.508) and GCS rate (- 0.8 [- 0.6, - 1.0] vs. - 0.8 [- 0.7, - 1.0]; p = 0.587) obtained using conventional and CS cine CMR. The GCS obtained using both methods showed excellent agreement (y = 0.99x - 0.24; r = 0.95; p < 0.001). The Bland-Altman analysis revealed that the mean difference in the GCS between the conventional and CS cine CMR was 0.1% with limits of agreement between -2.8% and 3.0%. No significant differences were found in all LV volume assessment between both types of cine CMR. CONCLUSION: CS cine CMR could be used for GCS assessment by CMR-FT as well as conventional cine CMR. This finding further enhances the clinical utility of high-speed CS cine CMR imaging.


Asunto(s)
Cardiopatías/diagnóstico por imagen , Interpretación de Imagen Asistida por Computador , Imagen por Resonancia Cinemagnética , Función Ventricular Izquierda , Remodelación Ventricular , Anciano , Femenino , Cardiopatías/fisiopatología , Humanos , Masculino , Persona de Mediana Edad , Valor Predictivo de las Pruebas , Estudios Prospectivos , Estudios Retrospectivos
5.
J Nucl Cardiol ; 28(5): 1851-1860, 2021 10.
Artículo en Inglés | MEDLINE | ID: mdl-31713117

RESUMEN

BACKGROUND: This study evaluated corrected relative flow reserve (RFR) derived from 13N-ammonia positron emission tomography (PET) combined with coronary computed tomography angiography (CTA). METHODS: We analyzed 61 patients who underwent coronary CTA, 13N-ammonia PET, and invasive coronary angiography. Triple-vessel disease were excluded. Conventional RFRs were calculated as the ratio of hyperemic myocardial blood flow (hMBF) of hypoperfusion areas to those of non-ischemic lesions. Corrected RFRs were calculated using PET and coronary CTA to adjust coronary territories to their feeding vessels. Diagnostic performance was compared to detect obstructive coronary lesions. RESULTS: Of the 180 vessels analyzed, 50 were diagnosed as obstructive lesions (≥ 70% stenosis and/or fractional flow reserve value ≤ 0.8). The coronary flow reserve (CFR), hMBF, conventional RFR, and corrected RFR of obstructive lesions were significantly lower than those of non-obstructive lesions. In receiver operating characteristic curve analysis, these quantitative PET measurements had area under the curve of 0.67, 0.71, 0.89, and 0.92, respectively. Diagnostic performance differences between corrected and conventional RFR were not statistically significant. CONCLUSION: In patients with single or double vessel disease, indices of RFR, with or without coronary angiographic guidance of the reference coronary territory, are better discriminators of flow-limiting stenoses than hMBF and CFR.


Asunto(s)
Angiografía por Tomografía Computarizada , Enfermedad de la Arteria Coronaria/diagnóstico por imagen , Reserva del Flujo Fraccional Miocárdico/fisiología , Radioisótopos de Nitrógeno , Tomografía Computarizada por Tomografía de Emisión de Positrones , Radiofármacos , Anciano , Enfermedad de la Arteria Coronaria/fisiopatología , Femenino , Humanos , Masculino , Persona de Mediana Edad , Valor Predictivo de las Pruebas , Curva ROC , Estudios Retrospectivos
6.
J Appl Clin Med Phys ; 22(7): 66-76, 2021 Jul.
Artículo en Inglés | MEDLINE | ID: mdl-33955161

RESUMEN

Volumetric-modulated arc therapy (VMAT) requires highly accurate control of multileaf collimator (MLC) movement, rotation speed of linear accelerator gantry, and monitor units during irradiation. Pretreatment validation and monitoring of these factors during irradiation are necessary for appropriate VMAT treatment. Recently, a gantry mounted transmission detector "Delta4 Discover® (D4D)" was developed to detect errors in delivering doses and dose distribution immediately after treatment. In this study, the performance of D4D was evaluated. Simulation plans, in which the MLC position was displaced by 0.5, 1.0, 1.5, 2.0, 2.5, and 3.0 mm from the clinically used original plans, were created for ten patients who received VMAT treatment for prostate cancer. Dose deviation (DD), distance-to-agreement (DTA), and gamma index analysis (GA) for each plan were evaluated by D4D. These results were compared to the results (DD, DTA and GA) measured by Delta4 Phantom + (D4P). We compared the deviations between the planned and measured values of the MLC stop positions A-side and B-side in five clinical cases of prostate VMAT during treatment and measured the GA values. For D4D, when the acceptable errors for DD, DTA, and GA were determined to be ≤3%, ≤2 mm, and ≤3%/2 mm, respectively, the minimum detectable errors in the MLC position were 2.0, 1.5, and 1.5 mm based on DD, DTA, and GA respectively. The corresponding minimum detectable MLC position errors were 2.0, 1.0, and 1.5 mm, respectively, for D4P. The deviation between the planned and measured position of MLC stopping point of prostate VMAT during treatment was stable at an average of -0.09 ± 0.05 mm, and all GA values were above 99.86%. In terms of delivering doses and dose distribution of VMAT, error detectability of D4D was comparable to that of D4P. The transmission-type detector "D4D" is thus suitable for detecting delivery errors during irradiation.


Asunto(s)
Neoplasias de la Próstata , Radioterapia de Intensidad Modulada , Humanos , Masculino , Aceleradores de Partículas , Fantasmas de Imagen , Neoplasias de la Próstata/radioterapia , Dosificación Radioterapéutica , Planificación de la Radioterapia Asistida por Computador
7.
Eur Radiol ; 30(11): 6109-6117, 2020 Nov.
Artículo en Inglés | MEDLINE | ID: mdl-32556462

RESUMEN

OBJECTIVES: This study evaluated the characteristics of left ventricular maximum principal strain (LV-MPS) using cardiac CT in subjects with normal LV function. METHODS: Of 973 subjects who underwent retrospective electrocardiogram-gated cardiac CT using a third-generation dual-source CT without beta-blocker administration, 31 subjects with preserved LV ejection fraction ≥ 55% assessed by echocardiography without coronary artery stenosis and cardiac pathology were retrospectively identified. CT images were reconstructed every 5% (0-95%) of the RR interval. LV-MPS and the time to peak (TTP) were analyzed using the 16-segment model and compared among three levels (base, mid, and apex) and among four regions (anterior, septum, inferior, and lateral) using the Steel-Dwass test. The intra- and inter-observer reproducibilities for LV-MPS were calculated using intraclass correlation coefficients (ICCs). RESULTS: The intra- and inter-observer ICCs (95% confidence interval) for peak LV-MPS were 0.96 (0.94-0.97) and 0.94 (0.92-0.96), respectively. The global peak LV-MPS (median, inter-quantile range) was 0.59 (0.55-0.72). The regional LV-MPS significantly increased in the order of the basal (0.54, 0.49-0.59), mid-LV (0.57, 0.53-0.65), and apex (0.68, 0.60-0.84) (p < 0.05, in each), and was significantly higher in the lateral wall (0.66, 0.60-0.77), while that in the septal region (0.47, 0.44-0.54) was the lowest among the four LV regions (all p < 0.05). No significant difference in TTP was seen among the myocardial levels and regions. CONCLUSION: CT-derived LV-MPS is reproducible and quantitatively represents synchronized myocardial contraction with heterogeneous values in subjects with normal LV function. KEY POINTS: • CT-derived left ventricular maximum principal strain analysis allows highly reproducible quantitative assessments of left ventricular myocardial contraction. • In subjects with normal cardiac function, the peak value of CT-derived left ventricular maximum principal strain is the highest in the apical level and in the lateral wall and the lowest in the septum. • The regional peak left ventricular maximum principal strain shows intra-ventricular heterogeneity on a per-patient basis, but myocardial contraction is globally synchronized in subjects with normal cardiac function seen on cardiac CT.


Asunto(s)
Ventrículos Cardíacos/diagnóstico por imagen , Contracción Miocárdica/fisiología , Volumen Sistólico/fisiología , Tomografía Computarizada por Rayos X/métodos , Función Ventricular Izquierda/fisiología , Ecocardiografía/métodos , Electrocardiografía , Femenino , Humanos , Masculino , Persona de Mediana Edad , Valores de Referencia , Estudios Retrospectivos
8.
J Cardiovasc Magn Reson ; 22(1): 66, 2020 09 14.
Artículo en Inglés | MEDLINE | ID: mdl-32921308

RESUMEN

BACKGROUND: Cardiovascular magnetic resonance (CMR) late gadolinium enhancement (LGE) is a valuable technique for detecting myocardial disorders and fibrosis. However, we sometimes observe a linear, mid-wall high intensity signal in the basal septum in the short axis view, which often presents diagnostic difficulties in the clinical setting. The purpose of this study was to compare the linear, mid-wall high intensity in the basal septum identified by LGE with the anterior septal perforator arteries identified by coronary computed tomography angiography (CorCTA). METHODS: We retrospectively selected 148 patients who underwent both CorCTA and CMR LGE within 1 year. In the interpretation of LGE, we defined a positive linear high intensity (LHI+) as follows: ① LHI in the basal septum and ② observable for 1.5 cm or more. All other patients were defined as a negative LHI (LHI-). In LHI+ patients, we assessed the correlation between the LHI length and the septal perforator artery length on CorCTA. We also compared the length of the septal perforator artery on CorCTA between LHI+ patients and LHI- patients. RESULTS: A population of 111 patients were used for further analysis. Among these , there were 55 LHI+ patients and 56 LHI- patients. In LHI+ patients, linear regression analysis revealed that there was a good agreement between LGE LHI and septal perforator arteries by CorCTA in terms of length measurements. The measured length of the anterior septal perforator arteries was significantly shorter in LHI- patients than in LHI+ patients (10 ± 8 mm vs. 21 ± 8 mm; P < 0.05). CONCLUSIONS: The LHI observed in the basal septum on short axis LGE may reflect contrast enhancement of the anterior septal perforator arteries. It is important to interpret this septal LHI against knowledge of anatomic structure, to avoid misinterpretations of LGE and prevent misdiagnosis.


Asunto(s)
Cardiomiopatías/diagnóstico por imagen , Angiografía por Tomografía Computarizada , Medios de Contraste/administración & dosificación , Angiografía Coronaria , Vasos Coronarios/diagnóstico por imagen , Gadolinio DTPA/administración & dosificación , Tabiques Cardíacos/diagnóstico por imagen , Imagen por Resonancia Cinemagnética , Isquemia Miocárdica/diagnóstico por imagen , Anciano , Artefactos , Femenino , Humanos , Masculino , Persona de Mediana Edad , Valor Predictivo de las Pruebas , Reproducibilidad de los Resultados , Estudios Retrospectivos
9.
J Cardiovasc Magn Reson ; 22(1): 15, 2020 02 13.
Artículo en Inglés | MEDLINE | ID: mdl-32050982

RESUMEN

BACKGROUND: Coronary magnetic resonance angiography (CMRA) is a promising technique for assessing the coronary arteries. However, a disadvantage of CMRA is the comparatively long acquisition time. Compressed sensing (CS) can considerably reduce the scan time. The aim of this study was to verify the feasibility of CS CMRA scanning during the waiting time between contrast injection and late gadolinium enhancement (LGE) scan in a clinical protocol. METHODS: Fifty clinical patients underwent contrast-enhanced CS CMRA and conventional CMRA on a 3 T CMR scanner. After contrast injection, CS CMRA was scanned during the waiting time for LGE CMR. A conventional CMRA scan was performed after LGE CMR. We assessed acquisition times and coronary artery image quality for each segment on a 4-point scale. Visible vessel length, sharpness and diameter of right (RCA), left anterior descending (LAD), and left circumflex (LCX) coronary arteries were also quantitatively compared among the scans. RESULTS: All CS CMRA scans were successfully performed within the LGE waiting time. The median total scan time was 207 s (163, 259 s) for CS and 785 s (698, 975 s) for conventional CMRA (p < 0.001). No significant differences were observed in image quality scores, vessel length measurements, sharpness, and diameter between CS and conventional CMRA. CONCLUSIONS: We could achieve all CS CMRA scans within the LGE waiting time. Contrast-enhanced CS CMRA could considerably shorten the scan time while maintaining image quality compared with conventional CMRA.


Asunto(s)
Medios de Contraste/administración & dosificación , Angiografía Coronaria/métodos , Enfermedad de la Arteria Coronaria/diagnóstico por imagen , Vasos Coronarios/diagnóstico por imagen , Interpretación de Imagen Asistida por Computador , Angiografía por Resonancia Magnética , Imagen por Resonancia Cinemagnética , Compuestos Organometálicos/administración & dosificación , Adulto , Anciano , Estudios de Factibilidad , Femenino , Humanos , Japón , Masculino , Persona de Mediana Edad , Valor Predictivo de las Pruebas , Estudios Prospectivos , Reproducibilidad de los Resultados , Factores de Tiempo , Flujo de Trabajo
10.
Circ J ; 84(4): 601-608, 2020 03 25.
Artículo en Inglés | MEDLINE | ID: mdl-32074543

RESUMEN

BACKGROUND: Although coronary computed tomography angiography (CTA) is frequently used for identifying coronary artery disease, no studies have investigated the radiation dose in detail in Japan. The aim of this study was to estimate the radiation dose of coronary CTA in Japanese clinical practice and to identify the independent predictors associated with radiation dose.Methods and Results:A multicenter, retrospective, observational study (54 institutions) was conducted for estimating the radiation dose of coronary CTA in 2,469 patients between January and December 2013. Independent predictors associated with radiation dose were investigated on linear regression analysis. Median dose-length product (DLP) was 809.0 mGy·cm (IQR, 350.0-1,368.8 mGy·cm), corresponding to an estimated radiation dose of 11 mSv. The DLP per site significantly differed between institutions (median DLP per site, 92-2,131 mGy·cm; P<0.05). Independent predictors associated with radiation dose on multivariable linear regression were body weight, heart rate, non-stable sinus rhythm, scan length, tube voltage setting, electrocardiogram (ECG)-gated scanning protocol, and the image reconstruction technique (P<0.05 each). CONCLUSIONS: The coronary CTA radiation dose was relatively high in 2013, and it varied significantly between institutions. Effective strategies for radiation dose reduction were low tube voltage ≤100 kVp, retrospective ECG-gated scanning with dose modulation technique, prospective ECG-gated scanning, and the iterative reconstruction technique.


Asunto(s)
Angiografía por Tomografía Computarizada , Angiografía Coronaria , Enfermedad de la Arteria Coronaria/diagnóstico por imagen , Tomografía Computarizada Multidetector , Dosis de Radiación , Exposición a la Radiación , Anciano , Técnicas de Imagen Sincronizada Cardíacas , Angiografía por Tomografía Computarizada/efectos adversos , Angiografía Coronaria/efectos adversos , Electrocardiografía , Femenino , Humanos , Japón , Masculino , Persona de Mediana Edad , Tomografía Computarizada Multidetector/efectos adversos , Valor Predictivo de las Pruebas , Exposición a la Radiación/efectos adversos , Exposición a la Radiación/prevención & control , Sistema de Registros , Estudios Retrospectivos
11.
Int J Clin Oncol ; 25(4): 691-697, 2020 Apr.
Artículo en Inglés | MEDLINE | ID: mdl-31897803

RESUMEN

BACKGROUND: To evaluate the treatment outcomes of external-beam radiotherapy (EBRT) with or without radioactive iodine therapy (RAIT) for metastatic or recurrent lesions of differentiated thyroid cancer (DTC). METHODS: Between August 1997 and March 2018, 73 lesions (distant metastases, 50; regional lymph-node metastases, 17; postoperative tumor-bed recurrences, 6) in 36 patients that had received EBRT with or without RAIT were reviewed. Doses of EBRT were 8-70 Gy (median 40 Gy). Seventeen patients received RAIT after EBRT. RESULTS: Median follow-up time of imaging studies was 14 months (range 1-110 months). Two-year overall survival rates and control rates of EBRT sites were 71% and 62%, respectively. Two-year control rates for EBRT of < 30 Gy (n = 7), 30 Gy (n = 13), 31-49 Gy (n = 25), 50 Gy (n = 20), and > 50 Gy (n = 8) were 0%, 56%, 53%, 79%, and 100%, respectively. There were statistically significant differences in control rates between < 30 Gy and 30 Gy (p = 0.003), and between 50 Gy and > 50 Gy (p = 0.037). Control rates of > 50 Gy were significantly better compared to ≤ 50 Gy (p = 0.021). Two-year control rates with (n = 28) and without (n = 45) post-EBRT RAIT were 89% and 45%, respectively (p = 0.009). In multivariate analysis, EBRT of > 50 Gy and post-EBRT RAIT were significant independent factors for favorable control of EBRT sites (hazard ratio [HR], 5.72; 95% confidence interval [CI], 1.21-27.1; p = 0.028 and HR, 2.98; 95% CI, 1.28-6.98; p = 0.012, respectively). CONCLUSION: EBRT of > 50 Gy and post-EBRT RAIT appeared to be useful for long-term control of EBRT sites for metastatic or recurrent lesions of DTC.


Asunto(s)
Neoplasias de la Tiroides/patología , Neoplasias de la Tiroides/radioterapia , Adulto , Anciano , Anciano de 80 o más Años , Femenino , Humanos , Radioisótopos de Yodo , Masculino , Persona de Mediana Edad , Recurrencia Local de Neoplasia , Radioterapia/métodos , Dosificación Radioterapéutica , Tasa de Supervivencia , Neoplasias de la Tiroides/mortalidad , Neoplasias de la Tiroides/cirugía , Resultado del Tratamiento
12.
Circ J ; 83(7): 1563-1571, 2019 06 25.
Artículo en Inglés | MEDLINE | ID: mdl-31178524

RESUMEN

BACKGROUND: This study evaluated the diagnostic capability of on-site coronary computed tomography-derived computational fractional flow reserve (CT-FFR) determinations for detecting coronary artery disease (CAD), as assessed by invasive fractional flow reserve (FFR).Methods and Results:Seventy-four patients with coronary artery calcium scores <1,500 who underwent coronary CT angiography (CTA) and invasive FFR measurements within 90 days were retrospectively reviewed. CT-FFR was computed using a prototype machine-learning (ML) algorithm in 91 vessels; 47 vessels of 42 patients were determined to have significant CAD (FFR ≤0.8). Correlation between CT-FFR and FFR was good (r=0.786, P<0.001). Per-vessel area under the curve was significantly larger for CT-FFR (0.907, 95% confidence interval: 0.828-0.958) than for CTA stenosis ≥50% (0.595, 0.487-0.697) or ≥70% (0.603, 0.495-0.705) (both P<0.001). Standard coronary CTA classifications recommended further functional tests in 57 patients with moderate or worse stenosis on CTA. CT-FFR analysis (mean analysis time: 16.4±7.5 min) corrected the standard coronary CTA classification in 18 of 74 patients and confirmed it in 45 of 74 patients. Thus, the per-patient diagnostic accuracy of the classifications was improved from 66% (54-77%) to 85% (75-92%). CONCLUSIONS: On-site CT-FFR based on a ML algorithm can provide good diagnostic performance for detecting hemodynamically significant CAD, suggesting the high value of coronary CTA for selected patients in clinical practice.


Asunto(s)
Angiografía por Tomografía Computarizada , Angiografía Coronaria , Enfermedad de la Arteria Coronaria , Reserva del Flujo Fraccional Miocárdico , Aprendizaje Automático , Anciano , Anciano de 80 o más Años , Enfermedad de la Arteria Coronaria/diagnóstico por imagen , Enfermedad de la Arteria Coronaria/fisiopatología , Femenino , Humanos , Masculino , Persona de Mediana Edad , Estudios Retrospectivos
13.
J Comput Assist Tomogr ; 43(5): 811-816, 2019.
Artículo en Inglés | MEDLINE | ID: mdl-31453979

RESUMEN

OBJECTIVE: Knowledge-based iterative model reconstruction (IMR) yields diagnostically acceptable image quality in low-dose static computed tomography (CT). We aimed to evaluate the feasibility of IMR in dynamic myocardial computed tomography perfusion (CTP). METHODS: We enrolled 24 patients who underwent stress dynamic CTP using a 256-slice CT. Images were reconstructed using filtered back projection (FBP), hybrid IR, and IMR. Image quality and hemodynamic parameters were compared among three algorithms. RESULTS: Qualitative image quality and contrast-to-noise ratio were significantly higher by IMR than by FBP or hybrid IR (visual score: 4.1 vs. 3.0 and 3.5; contrast-to-noise ratio: 12.4 vs. 6.6 and 8.4; P < 0.05). No significant difference was observed among algorithms in CTP-derived myocardial blood flow (1.68 vs. 1.73 and 1.70 mL/g/min). CONCLUSIONS: The use of knowledge-based iterative model reconstruction improves image quality without altering hemodynamic parameters in low-dose dynamic CTP, compared with FBP or hybrid IR.


Asunto(s)
Angiografía por Tomografía Computarizada/métodos , Angiografía Coronaria/métodos , Enfermedad de la Arteria Coronaria/diagnóstico por imagen , Enfermedad de la Arteria Coronaria/fisiopatología , Hemodinámica/fisiología , Bases del Conocimiento , Tomografía Computarizada Multidetector/métodos , Anciano , Algoritmos , Técnicas de Imagen Sincronizada Cardíacas , Medios de Contraste , Prueba de Esfuerzo , Estudios de Factibilidad , Femenino , Humanos , Yopamidol , Masculino , Persona de Mediana Edad , Interpretación de Imagen Radiográfica Asistida por Computador/métodos , Estudios Retrospectivos
14.
Int J Clin Oncol ; 24(9): 1119-1128, 2019 Sep.
Artículo en Inglés | MEDLINE | ID: mdl-31079257

RESUMEN

BACKGROUND: To evaluate the prognostic value of tumor growth patterns on magnetic resonance (MR) images in patients with locally advanced cervical cancer (LACC) treated with definitive radiotherapy or concurrent chemoradiotherapy (RT/CCRT). METHODS: We retrospectively reviewed 102 patients with LACC who received definitive RT/CCRT and who underwent MR imaging before RT/CCRT. Growth patterns on pretreatment T2-weighted MR images were classified into expansive or infiltrative type according to tumor morphologic patterns in the myometrium and/or parametrial space. RESULTS: The median age was 60 years (range 26-90 years). The median follow-up time was 47.7 months (range 5.7-123 months). The numbers of patients with stages IB, II, III, and IVA were 17, 39, 43, and 3, respectively. The 3-year overall survival (OS) rates for stages IB, II, III, and IV were 87%, 76%, 74%, and 67%, respectively. Regarding growth patterns on MR images, 31 were of expansive type and 71 were of infiltrative type. The infiltrative type was significantly associated with lower OS and locoregional recurrence-free survival (LRRFS) than the expansive type (3-year OS, 70% vs. 93%, p = 0.003; 3-year LRRFS, 64% vs. 94%, p = 0.001). On multivariate analysis, infiltrative tumor growth patterns were a significant independent factor for low OS (hazard ratio [HR], 3.81; 95% confidence interval [CI] 1.26-16.7; p = 0.015) and low LRRFS (HR, 4.27; 95% CI 1.43-18.5; p = 0.007). CONCLUSION: Tumor growth patterns on MR images could be an indicator of survival and locoregional control in patients with LACC treated with definitive RT/CCRT.


Asunto(s)
Neoplasias del Cuello Uterino/diagnóstico por imagen , Neoplasias del Cuello Uterino/terapia , Adulto , Anciano , Anciano de 80 o más Años , Quimioradioterapia/métodos , Femenino , Humanos , Imagen por Resonancia Magnética , Persona de Mediana Edad , Pronóstico , Modelos de Riesgos Proporcionales , Estudios Retrospectivos , Tasa de Supervivencia , Resultado del Tratamiento , Neoplasias del Cuello Uterino/mortalidad , Neoplasias del Cuello Uterino/patología
15.
Eur Radiol ; 28(3): 1285-1292, 2018 Mar.
Artículo en Inglés | MEDLINE | ID: mdl-28929333

RESUMEN

OBJECTIVE: To evaluate the feasibility of image subtraction in late iodine enhancement CT (LIE-CT) for assessment of myocardial infarction (MI). METHODS: A comprehensive cardiac CT protocol and late gadolinium enhancement MRI (LGE-MRI) was used to assess coronary artery disease in 27 patients. LIE-CT was performed after stress CT perfusion (CTP) and CT angiography. Subtraction LIE-CT was created by subtracting the mask volume of the left ventricle (LV) cavity from the original LIE-CT using CTP dataset. The %MI volume was quantified as the ratio of LIE to entire LV volume, and transmural extent (TME) of LIE was classified as 0%, 1-24%, 25-49%, 50-74% or 75-100%. These results were compared with LGE-MRI using the Spearman rank test, Bland-Altman method and chi-square test. RESULTS: One hundred twenty-five (29%) of 432 segments were positive on LGE-MRI. Correlation coefficients for original and subtraction LIE-CT to LGE-MRI were 0.79 and 0.85 for %MI volume. Concordances of the 5-point grading scale between original and subtraction LIE-CT with LGE-MRI were 75% and 84% for TME; concordance was significantly improved using the subtraction technique (p <0.05). CONCLUSION: Subtraction LIE-CT allowed more accurate assessment of MI extent than the original LIE-CT. KEY POINTS: • Subtraction LIE-CT allows for accurate assessment of the extent of myocardial infarction. • Subtraction LIE-CT shows a close correlation with LGE-MRI in %MI volume. • Subtraction LIE-CT has significantly higher concordance with TME assessment than original LIE-CT.


Asunto(s)
Angiografía de Substracción Digital/métodos , Angiografía por Tomografía Computarizada/métodos , Vasos Coronarios/diagnóstico por imagen , Ventrículos Cardíacos/diagnóstico por imagen , Yopamidol/farmacología , Tomografía Computarizada Multidetector/métodos , Infarto del Miocardio/diagnóstico , Medios de Contraste/farmacología , Femenino , Humanos , Yodo , Imagen por Resonancia Cinemagnética/métodos , Masculino , Persona de Mediana Edad , Valor Predictivo de las Pruebas , Intensificación de Imagen Radiográfica , Factores de Tiempo
16.
Circ J ; 82(2): 486-493, 2018 01 25.
Artículo en Inglés | MEDLINE | ID: mdl-28954967

RESUMEN

BACKGROUND: This study aimed to evaluate the diagnostic performance of coronary flow reserve (CFR), hyperemic myocardial blood flow (hMBF), and CFR ratio for detecting significant coronary artery disease (CAD) on 13N-ammonia positron emission tomography (PET).Methods and Results:We analyzed 63 patients (mean age, 71±9 years; 43 males) with suspected CAD who underwent both pharmacological stress/rest 13N-ammonia PET and coronary angiography. CFR and hMBF for PET were calculated automatically using quantitative PET software, and the CFR ratio was defined as the ratio of per-vessel CFR to maximum CFR in a standard 17-segment model. We compared the diagnostic performance among the 3 quantitative values. In the per-vessel analysis, 55 vessels were diagnosed as significant CAD (≥70% stenosis and/or fraction flow reserve ≤0.8). CFR, hMBF, and CFR ratio of significant CAD were significantly lower than for non-significant CAD (1.85±0.69 vs. 2.38±0.69; P<0.01, 1.67±0.54 vs. 2.19±0.52 mL·min-1·g-1; P<0.01, and 0.66±0.15 vs. 0.82±0.09; P<0.01, respectively). In the receiver-operating characteristic curve analysis, CFR, hMBF, and CFR ratio had areas under the curve of 0.71, 0.75, and 0.85 respectively, and the CFR ratio was significantly higher than CFR and hMBF (P<0.05). The sensitivity, specificity, and accuracy of the CFR ratio with an optimal cutoff value of 0.75 were 75%, 85%, and 82%, respectively. CONCLUSIONS: Clinically, the CFR ratio in 13N-ammonia PET was more effective in detecting significant CAD.


Asunto(s)
Enfermedad de la Arteria Coronaria/diagnóstico , Circulación Coronaria , Reserva del Flujo Fraccional Miocárdico , Hiperemia/fisiopatología , Tomografía de Emisión de Positrones/métodos , Anciano , Anciano de 80 o más Años , Amoníaco , Femenino , Humanos , Masculino , Persona de Mediana Edad , Radioisótopos de Nitrógeno , Curva ROC , Sensibilidad y Especificidad
17.
J Comput Assist Tomogr ; 42(6): 937-943, 2018.
Artículo en Inglés | MEDLINE | ID: mdl-29659425

RESUMEN

PURPOSE: This study aimed to evaluate the utility of virtual monoenergetic images for detecting washout of small (≤2 cm) hepatocellular carcinoma (HCC) in the equilibrium phase. METHODS: We performed 120-kVp-equivalent linear-blended (M120) and monoenergetic reconstructions from 40 to 90 keV by standard (40, 50, 60, 70, 80, 90) and novel noise-reduced (nMERA: 40+, 50+, 60+, 70+, 80+, 90+) monoenergetic reconstruction algorithms. Image quality and tumor visibility of delayed washout of HCCs in the equilibrium phase were compared between standard monoenergetic reconstruction algorithm and nMERA by objective and subjective analyses. RESULTS: Contrast-to-noise ratio of the tumor at 40+ was the highest, whereas the score of tumor visibility peaked at 50+. The score of overall image quality at 40+ was significantly lower than those on all other image series, and the image quality among other image series were not significantly different. CONCLUSIONS: Virtual monoenergetic image reconstructed with nMERA 50+ was most appropriate to detect washout of small HCCs.


Asunto(s)
Carcinoma Hepatocelular/diagnóstico por imagen , Neoplasias Hepáticas/diagnóstico por imagen , Interpretación de Imagen Radiográfica Asistida por Computador/métodos , Imagen Radiográfica por Emisión de Doble Fotón/métodos , Tomografía Computarizada por Rayos X/métodos , Anciano , Anciano de 80 o más Años , Algoritmos , Medios de Contraste , Femenino , Humanos , Masculino , Persona de Mediana Edad , Estudios Retrospectivos
18.
Pediatr Cardiol ; 39(3): 518-525, 2018 Mar.
Artículo en Inglés | MEDLINE | ID: mdl-29214485

RESUMEN

To assess a two-phase contrast injection protocol for contrast enhancement during cardiac computed tomography (CT) in children with congenital heart disease. Forty-three children (20 boys, 23 girls) of median age 13 months (range 3 days-8.3 years) and weighing ≤ 20 kg who underwent cardiac CT using a two-phase contrast injection protocol at our institution were retrospectively identified. High-pitch spiral third-generation dual-source cardiac CT (tube voltage 70 kV) was performed with a fixed delay of 60 s after contrast injection in the order of 10 mgI/kg/s (30 s), 15 mgI/kg/s (20 s), and a saline chaser (10 s). Attenuation in the inferior vena cava (IVC), superior vena cava (SVC), right atrium (RA), right ventricle (RV), pulmonary artery (PA), left atrium (LA), left ventricle (LV), and descending aorta (AO) was compared using the Steel-Dwass and Fisher's exact tests. The median (interquartile range) attenuation in the IVC, SVC, RA, RV, PA, LA, LV, and AO was 285 (264-347) Hounsfield units (HU), 416 (370-445) HU, 368 (320-388) HU, 373 (322-417) HU, 397 (330-432) HU, 425 (373-469) HU, 435 (385-468) HU, and 437 (392-491) HU, respectively (p < 0.05, IVC vs. the other anatomic sites). There was no significant difference in diagnostic success rate for attenuation > 250 HU between the IVC (41 children, 95.3%) and the other sites (43 children, 100%). A two-phase contrast injection protocol is useful for effective contrast enhancement in pediatric cardiac CT.


Asunto(s)
Medios de Contraste/administración & dosificación , Cardiopatías Congénitas/diagnóstico por imagen , Tomografía Computarizada por Rayos X/métodos , Aorta Torácica/diagnóstico por imagen , Niño , Preescolar , Femenino , Atrios Cardíacos/diagnóstico por imagen , Ventrículos Cardíacos/diagnóstico por imagen , Humanos , Lactante , Recién Nacido , Inyecciones Intravenosas/métodos , Masculino , Arteria Pulmonar/diagnóstico por imagen , Estudios Retrospectivos , Vena Cava Inferior/diagnóstico por imagen , Vena Cava Superior/diagnóstico por imagen
19.
Radiology ; 282(2): 381-389, 2017 Feb.
Artículo en Inglés | MEDLINE | ID: mdl-27541687

RESUMEN

Purpose To assess the ability of fast-kilovolt-peak switching dual-energy computed tomography (CT) by using the multimaterial decomposition (MMD) algorithm to quantify liver fat. Materials and Methods Fifteen syringes that contained various proportions of swine liver obtained from an abattoir, lard in food products, and iron (saccharated ferric oxide) were prepared. Approval of this study by the animal care and use committee was not required. Solid cylindrical phantoms that consisted of a polyurethane epoxy resin 20 and 30 cm in diameter that held the syringes were scanned with dual- and single-energy 64-section multidetector CT. CT attenuation on single-energy CT images (in Hounsfield units) and MMD-derived fat volume fraction (FVF; dual-energy CT FVF) were obtained for each syringe, as were magnetic resonance (MR) spectroscopy measurements by using a 1.5-T imager (fat fraction [FF] of MR spectroscopy). Reference values of FVF (FVFref) were determined by using the Soxhlet method. Iron concentrations were determined by inductively coupled plasma optical emission spectroscopy and divided into three ranges (0 mg per 100 g, 48.1-55.9 mg per 100 g, and 92.6-103.0 mg per 100 g). Statistical analysis included Spearman rank correlation and analysis of covariance. Results Both dual-energy CT FVF (ρ = 0.97; P < .001) and CT attenuation on single-energy CT images (ρ = -0.97; P < .001) correlated significantly with FVFref for phantoms without iron. Phantom size had a significant effect on dual-energy CT FVF after controlling for FVFref (P < .001). The regression slopes for CT attenuation on single-energy CT images in 20- and 30-cm-diameter phantoms differed significantly (P = .015). In sections with higher iron concentrations, the linear coefficients of dual-energy CT FVF decreased and those of MR spectroscopy FF increased (P < .001). Conclusion Dual-energy CT FVF allows for direct quantification of fat content in units of volume percent. Dual-energy CT FVF was larger in 30-cm than in 20-cm phantoms, though the effect of object size on fat estimation was less than that of CT attenuation on single-energy CT images. In the presence of iron, dual-energy CT FVF led to underestimateion of FVFref to a lesser degree than FF of MR spectroscopy led to overestimation of FVFref. © RSNA, 2016 Online supplemental material is available for this article.


Asunto(s)
Algoritmos , Hígado Graso/diagnóstico por imagen , Hígado Graso/patología , Imagen Radiográfica por Emisión de Doble Fotón/métodos , Tomografía Computarizada por Rayos X/métodos , Animales , Técnicas In Vitro , Espectroscopía de Resonancia Magnética/métodos , Fantasmas de Imagen , Porcinos
20.
Radiology ; 283(1): 108-118, 2017 04.
Artículo en Inglés | MEDLINE | ID: mdl-28212047

RESUMEN

Purpose To assess the clinical accuracy and reproducibility of liver fat quantification with the multimaterial decomposition (MMD) algorithm, comparing the performance of MMD with that of magnetic resonance (MR) spectroscopy by using liver biopsy as the reference standard. Materials and Methods This prospective study was approved by the institutional ethics committee, and patients provided written informed consent. Thirty-three patients suspected of having hepatic steatosis underwent non-contrast material-enhanced and triple-phase dynamic contrast-enhanced dual-energy computed tomography (CT) (80 and 140 kVp) and single-voxel proton MR spectroscopy within 30 days before liver biopsy. Percentage fat volume fraction (FVF) images were generated by using the MMD algorithm on dual-energy CT data to measure hepatic fat content. FVFs determined by using dual-energy CT and percentage fat fractions (FFs) determined by using MR spectroscopy were compared with histologic steatosis grade (0-3, as defined by the nonalcoholic fatty liver disease activity score system) by using Jonckheere-Terpstra trend tests and were compared with each other by using Bland-Altman analysis. Real non-contrast-enhanced FVFs were compared with triple-phase contrast-enhanced FVFs to determine the reproducibility of MMD by using Bland-Altman analyses. Results Both dual-energy CT FVF and MR spectroscopy FF increased with increasing histologic steatosis grade (trend test, P < .001 for each). The Bland-Altman plot of dual-energy CT FVF and MR spectroscopy FF revealed a proportional bias, as indicated by the significant positive slope of the line regressing the difference on the average (P < .001). The 95% limits of agreement for the differences between real non-contrast-enhanced and contrast-enhanced FVFs were not greater than about 2%. Conclusion The MMD algorithm quantifying hepatic fat in dual-energy CT images is accurate and reproducible across imaging phases. © RSNA, 2017 Online supplemental material is available for this article.


Asunto(s)
Hígado Graso/diagnóstico por imagen , Imagen Radiográfica por Emisión de Doble Fotón/métodos , Tomografía Computarizada por Rayos X/métodos , Adulto , Anciano , Algoritmos , Biopsia , Hígado Graso/patología , Femenino , Humanos , Hígado/diagnóstico por imagen , Hígado/patología , Espectroscopía de Resonancia Magnética , Masculino , Persona de Mediana Edad , Estudios Prospectivos , Reproducibilidad de los Resultados , Sensibilidad y Especificidad , Índice de Severidad de la Enfermedad
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA