Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 2 de 2
Filtrar
Más filtros

Bases de datos
Tipo del documento
Asunto de la revista
País de afiliación
Intervalo de año de publicación
1.
J Prosthodont ; 31(4): 333-340, 2022 Apr.
Artículo en Inglés | MEDLINE | ID: mdl-34288219

RESUMEN

PURPOSE: To provide, in a clinical case-control study, 1-year data on edentulous residual ridge dimensional changes for patients wearing removable partial dentures (RPD) with Polyetheretherketone (PEEK) framework, fabricated with a digital workflow, and a control group of untreated patients. MATERIALS AND METHODS: Ten patients were treated with PEEK RPD, and six controls were studied. Intraoral scans at baseline (T0) and after a median period of 1 year (T1) were superimposed, trimmed, and reoriented (T0r and T1r), moved to a metrology software, and realigned. A curve (C0) was then traced on T0r, along the residual ridge crest; its projection (C1) on T1r was obtained. The mean distance C0-C1 was the dependent variable of interest and represented the 1-year changes in the height of the edentulous ridge. In addition, mean 3D distance between T0 and T1 at each edentulous area was measured. Differences in these outcomes measured between RPD treated and control groups were statistically assessed. RESULTS: Twenty-six and 14 edentulous areas were investigated in the RPD treated and control groups, respectively. No significant differences were observed for potentially confounding variables, such as median follow-up time (12.5 vs. 13 months, respectively), the alignment accuracy between T0r and T1r (0.01 mm vs. 0 mm, respectively), the median number of remaining teeth (6 vs. 8.5, respectively), and the median length of edentulous areas (25.5 mm vs. 22.8 mm, respectively). For the outcomes of interest, no statistically significant difference was seen in the mean distance between C0 and C1 (i.e., changes in residual ridge height: -0.39 ± 0.52 mm vs. -0.52 ± 0.54 mm, respectively) or in the mean 3D distance at corresponding points of the denture bearing areas (-0.3 ± 0.46 mm vs. -0.4 ± 0.35, respectively). CONCLUSIONS: Although 1 year is a relatively short observation period, this clinical study shows that there are no short-term differences in edentulous residual ridge height and overall dimensions between patients wearing PEEK RPD, fabricated with a digital workflow, and controls without an RPD.


Asunto(s)
Dentadura Parcial Removible , Boca Edéntula , Benzofenonas , Estudios de Casos y Controles , Dentadura Parcial Removible/efectos adversos , Humanos , Polímeros
2.
J Prosthet Dent ; 121(6): 871-875, 2019 Jun.
Artículo en Inglés | MEDLINE | ID: mdl-30885588

RESUMEN

This clinical report describes a comprehensive digital approach with the Digital Smile System (DSS) and its clinical use in the prosthetic treatment of a patient for whom 6 anterior maxillary porcelain veneers were fabricated. Following this digital protocol, extraoral facial images and a diagnostic intraoral digital scan were obtained. Digital smile analysis, virtual diagnostic waxing, and milled trial restorations were made in the diagnostic phase. After tooth preparation, data from digital scans were used in the computer-aided design and computer-aided manufacturing (CAD-CAM) of the definitive restorations.


Asunto(s)
Diseño de Prótesis Dental , Sonrisa , Diseño Asistido por Computadora , Porcelana Dental , Humanos , Preparación del Diente
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA