Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 8 de 8
Filtrar
1.
Radiat Environ Biophys ; 56(4): 471-480, 2017 11.
Artículo en Inglés | MEDLINE | ID: mdl-28929295

RESUMEN

This work deals with the dosimetric features of a particular phenolic compound (IRGANOX 1076®) for dosimetry of clinical photon beams by using electron spin resonance (ESR) spectroscopy. After the optimization of the ESR readout parameters (namely modulation amplitude and microwave power) to maximise the signal without excessive spectrum distortions, basic dosimetric properties of laboratory-made phenolic dosimeters in pellet form, such as reproducibility, dose-response, sensitivity, linearity and dose rate dependence were investigated. The dosimeters were tested by measuring the depth dose profile of a 6 MV photon beam. A satisfactory intra-batch reproducibility of the ESR signal of the manufactured dosimeters was obtained. The ESR signal proved to increase linearly with increasing dose in the investigated dose range 1-13 Gy. The presence of an intrinsic background signal limits the minimum detectable dose to a value of approximately 0.6 Gy. Reliable and accurate assessment of the dose was achieved, independently of the dose rate. Such characteristics, together with the fact that IRGANOX 1076® is almost tissue-equivalent, and the stability of the ESR signal, make these dosimeters promising materials for ESR dosimetric applications in radiotherapy.


Asunto(s)
Fenoles/química , Fotones/uso terapéutico , Radiometría/métodos , Espectroscopía de Resonancia por Spin del Electrón , Microondas , Modelos Moleculares , Conformación Molecular , Dosificación Radioterapéutica
2.
Biomedicines ; 10(10)2022 Oct 13.
Artículo en Inglés | MEDLINE | ID: mdl-36289830

RESUMEN

We report on the early clinical outcomes of a prospective series of early breast cancer (EBC) patients treated with ultra-hypofractionated post-operative whole-breast irradiation (WBI) after breast-conserving surgery (BCS) and axillary management. Primary endpoints were patient's compliance and acute toxicity. Secondary endpoints included physician-rated cosmesis and ipsilateral breast tumour recurrence (IBTR). Acute toxicity was evaluated at the end of WBI, 3 weeks and 6 months thereafter, according to the Common Terminology Criteria for Adverse Events (v. 5.0). Patients were treated between September 2021 and May 2022. The treatment schedule for WBI consisted of either 26 Gy in 5 fractions over one week (standard approach) or 28.5 Gy in 5 fractions over 5 weeks (reserved to elders). Inverse planned intensity-modulated radiation therapy (IMRT) was used employing a static technique. A total of 70 patients were treated. Fifty-nine were treated with the 26 Gy/5 fr/1 w and 11 with the 28.5 Gy/5 fr/5 ws schedule. Median age was 67 and 70 in the two groups. Most of the patients had left-sided tumours (53.2%) in the 26 Gy/5 fr/1 w or right-sided lesions (63.6%) in the 28.5 Gy/5 fr/5 ws group. Most of the patients had a clinical T1N0 disease and a pathological pT1pN0(sn) after surgery. Ductal invasive carcinoma was the most frequent histology. Luminal A intrinsic subtyping was most frequent. Most of the patients underwent BCS and sentinel lymph node biopsy and adjuvant endocrine therapy. All patients completed the treatment program as planned. Maximum detected acute skin toxicities were grade 2 erythema (6.7%), grade 2 induration (4.4%), and grade 2 skin colour changes. No early IBTR was observed. Ultra-hypofractionated WBI provides favourable compliance and early clinical outcomes in EBC after BCS in a real-world setting.

3.
J Digit Imaging ; 21(3): 329-37, 2008 Sep.
Artículo en Inglés | MEDLINE | ID: mdl-17549564

RESUMEN

This note describes a method to characterize the performances of image fusion software (Syntegra) with respect to accuracy and robustness. Computed tomography (CT), magnetic resonance imaging (MRI), and single-photon emission computed tomography (SPECT) studies were acquired from two phantoms and 10 patients. Image registration was performed independently by two couples composed of one radiotherapist and one physicist by means of superposition of anatomic landmarks. Each couple performed jointly and saved the registration. The two solutions were averaged to obtain the gold standard registration. A new set of estimators was defined to identify translation and rotation errors in the coordinate axes, independently from point position in image field of view (FOV). Algorithms evaluated were local correlation (LC) for CT-MRI, normalized mutual information (MI) for CT-MRI, and CT-SPECT registrations. To evaluate accuracy, estimator values were compared to limiting values for the algorithms employed, both in phantoms and in patients. To evaluate robustness, different alignments between images taken from a sample patient were produced and registration errors determined. LC algorithm resulted accurate in CT-MRI registrations in phantoms, but exceeded limiting values in 3 of 10 patients. MI algorithm resulted accurate in CT-MRI and CT-SPECT registrations in phantoms; limiting values were exceeded in one case in CT-MRI and never reached in CT-SPECT registrations. Thus, the evaluation of robustness was restricted to the algorithm of MI both for CT-MRI and CT-SPECT registrations. The algorithm of MI proved to be robust: limiting values were not exceeded with translation perturbations up to 2.5 cm, rotation perturbations up to 10 degrees and roto-translational perturbation up to 3 cm and 5 degrees.


Asunto(s)
Algoritmos , Encéfalo/anatomía & histología , Encéfalo/diagnóstico por imagen , Imagen por Resonancia Magnética/métodos , Reconocimiento de Normas Patrones Automatizadas/métodos , Intensificación de Imagen Radiográfica/instrumentación , Diseño de Software , Encéfalo/patología , Neoplasias Encefálicas/diagnóstico , Femenino , Glioma/diagnóstico , Humanos , Almacenamiento y Recuperación de la Información/métodos , Imagen por Resonancia Magnética/instrumentación , Masculino , Fantasmas de Imagen , Intensificación de Imagen Radiográfica/métodos , Sensibilidad y Especificidad , Tecnecio Tc 99m Sestamibi , Tomografía Computarizada de Emisión de Fotón Único/métodos
4.
Phys Med Biol ; 62(10): 4218-4236, 2017 05 21.
Artículo en Inglés | MEDLINE | ID: mdl-28252444

RESUMEN

Over the years, many efforts have been made to develop radiation detectors to handle the complex issues of small field dosimetry and achieve the increasing accuracy, precision and in vivo dose monitoring required by the new advanced treatment modalities. In this context, interest has surged in the development of sensors based on scintillating optical fibres. In this paper, the near-infrared radioluminescence and dosimetric properties of Yb-doped silica optical fibres, coupled with a laboratory prototype based on an avalanche photodiode, were studied by irradiating the fibres with photons and electron beams generated by a Varian Trilogy accelerator. The performance of the system in standard and small field sizes has also been investigated, comparing the output factor, percentage depth dose and off-axis ratio measurements of the prototypal detector with other commercial sensors, including the Exradin W1 scintillator. The results of this study demonstrate that the drawback due to the stem effect in Yb-doped silica optical fibres can be managed in a simple but effective way by optical filtering. The robustness of the system in complex dosimetric scenarios and the accuracy and precision achieved by Yb-doped fibres in relative dose assessments suggest an effective use of the system for real-time in vivo dosimetry applications.


Asunto(s)
Fibras Ópticas , Radiometría/instrumentación , Dióxido de Silicio/química , Iterbio/química , Fotones , Factores de Tiempo
5.
Pract Radiat Oncol ; 4(6): 392-7, 2014.
Artículo en Inglés | MEDLINE | ID: mdl-25407860

RESUMEN

PURPOSE: The aim of this study was to analyze the application of the failure modes and effects analysis (FMEA) to intracranial stereotactic radiation surgery (SRS) by linear accelerator in order to identify the potential failure modes in the process tree and adopt appropriate safety measures to prevent adverse events (AEs) and near-misses, thus improving the process quality. METHODS AND MATERIALS: A working group was set up to perform FMEA for intracranial SRS in the framework of a quality assurance program. FMEA was performed in 4 consecutive tasks: (1) creation of a visual map of the process; (2) identification of possible failure modes; (3) assignment of a risk probability number (RPN) to each failure mode based on tabulated scores of severity, frequency of occurrence and detectability; and (4) identification of preventive measures to minimize the risk of occurrence. RESULTS: The whole SRS procedure was subdivided into 73 single steps; 116 total possible failure modes were identified and a score of severity, occurrence, and detectability was assigned to each. Based on these scores, RPN was calculated for each failure mode thus obtaining values from 1 to 180. In our analysis, 112/116 (96.6%) RPN values were <60, 2 (1.7%) between 60 and 125 (63, 70), and 2 (1.7%) >125 (135, 180). The 2 highest RPN scores were assigned to the risk of using the wrong collimator's size and incorrect coordinates on the laser target localizer frame. CONCLUSION: Failure modes and effects analysis is a simple and practical proactive tool for systematic analysis of risks in radiation therapy. In our experience of SRS, FMEA led to the adoption of major changes in various steps of the SRS procedure.


Asunto(s)
Neoplasias Encefálicas/cirugía , Aceleradores de Partículas , Radiocirugia/instrumentación , Radiocirugia/métodos , Neoplasias Encefálicas/patología , Humanos , Medición de Riesgo
6.
Radiat Oncol ; 5: 10, 2010 Feb 06.
Artículo en Inglés | MEDLINE | ID: mdl-20137093

RESUMEN

BACKGROUND: FDG-PET/CT imaging has an emerging role in staging and treatment planning of various tumor locations and a number of literature studies show that also the carcinoma of the anal canal may benefit from this diagnostic approach. We analyzed the potential impact of FDG-PET/CT in stage definition and target volume delineation of patients affected by carcinoma of the anal canal and candidates for curative radiotherapy. METHODS: Twenty seven patients with biopsy proven anal carcinoma were enrolled. Pathology was squamous cell carcinoma in 20 cases, cloacogenic carcinoma in 3, adenocarcinoma in 2, and basal cell carcinoma in 2. Simulation was performed by PET/CT imaging with patient in treatment position. Gross Tumor Volume (GTV) and Clinical Target Volume (CTV) were drawn on CT and on PET/CT fused images. PET-GTV and PET-CTV were respectively compared to CT-GTV and CT-CTV by Wilcoxon rank test for paired data. RESULTS: PET/CT fused images led to change the stage in 5/27 cases (18.5%): 3 cases from N0 to N2 and 2 from M0 to M1 leading to change the treatment intent from curative to palliative in a case.Based on PET/CT imaging, GTV and CTV contours changed in 15/27 (55.6%) and in 10/27 cases (37.0%) respectively. PET-GTV and PET-CTV resulted significantly smaller than CT-GTV (p = 1.2 x 10(-4)) and CT-CTV (p = 2.9 x 10(-4)). PET/CT-GTV and PET/CT-CTV, that were used for clinical purposes, were significantly greater than CT-GTV (p = 6 x 10(-5)) and CT-CTV (p = 6 x 10(-5)). CONCLUSIONS: FDG-PET/CT has a potential relevant impact in staging and target volume delineation of the carcinoma of the anal canal. Clinical stage variation occurred in 18.5% of cases with change of treatment intent in 3.7%. The GTV and the CTV changed in shape and in size based on PET/CT imaging.


Asunto(s)
Neoplasias del Ano/patología , Carcinoma/patología , Estadificación de Neoplasias/métodos , Planificación de la Radioterapia Asistida por Computador/métodos , Radioterapia Conformacional , Adulto , Anciano , Anciano de 80 o más Años , Femenino , Fluorodesoxiglucosa F18 , Humanos , Masculino , Persona de Mediana Edad , Tomografía de Emisión de Positrones , Radiofármacos , Tomografía Computarizada por Rayos X
7.
Int J Radiat Oncol Biol Phys ; 76(4): 1073-7, 2010 Mar 15.
Artículo en Inglés | MEDLINE | ID: mdl-19625135

RESUMEN

PURPOSE: To analyze the feasibility of intraoperative radiotherapy (IORT) in patients with high-risk prostate cancer and candidates for radical prostatectomy. METHODS AND MATERIALS: A total of 38 patients with locally advanced prostate cancer were enrolled. No patients had evidence of lymph node or distant metastases, probability of organ-confined disease >25%, or risk of lymph node involvement >15% according to the Memorial Sloan-Kettering Cancer Center Nomogram. The IORT was delivered after exposure of the prostate by a dedicated linear accelerator with beveled collimators using electrons of 9 to 12 MeV to a total dose of 10-12 Gy. Rectal dose was measured in vivo by radiochromic films placed on a rectal probe. Adminstration of IORT was followed by completion of radical prostatectomy and regional lymph node dissection. All cases with extracapsular extension and/or positive margins were scheduled for postoperative radiotherapy. Patients with pT3 to pT4 disease or positive nodes received adjuvant hormonal therapy. RESULTS: Mean dose detected by radiochromic films was 3.9 Gy (range, 0.4-8.9 Gy) to the anterior rectal wall. The IORT procedure lasted 31 min on average (range, 15-45 min). No major intra- or postoperative complications occurred. Minor complications were observed in 10/33 (30%) of cases. Of the 27/31 patients who completed the postoperative external beam radiotherapy, 3/27 experienced Grade 2 rectal toxicity and 1/27 experienced Grade 2 urinary toxicity. CONCLUSIONS: Use of IORT during radical prostatectomy is feasible and allows safe delivery of postoperative external beam radiotherapy to the tumor bed without relevant acute rectal toxicity.


Asunto(s)
Neoplasias de la Próstata/radioterapia , Neoplasias de la Próstata/cirugía , Recto/efectos de la radiación , Anciano , Quimioterapia Adyuvante , Estudios de Factibilidad , Dosimetría por Película/métodos , Humanos , Periodo Intraoperatorio , Escisión del Ganglio Linfático , Masculino , Persona de Mediana Edad , Prostatectomía/métodos , Neoplasias de la Próstata/patología , Dosificación Radioterapéutica
8.
Radiat Oncol ; 4: 9, 2009 Feb 22.
Artículo en Inglés | MEDLINE | ID: mdl-19232137

RESUMEN

BACKGROUND: The reproducibility of patient setup for radiotherapy is based on various methods including external markers, X-rays with planar or computerized image acquisition, and, more recently, surface matching imaging. We analyzed the setup reproducibility of 16 patients affected by prostate cancer who underwent conformal radiotherapy with curative intent by using a surface image registration system. METHODS: We analyzed the setup reproducibility of 16 patients affected by prostate cancer candidates for conformal radiotherapy by using a surface image registration system. At the initial setup, EPID images were compared with DRRs and a reference 3D surface image was obtained by the AlignRT system (Vision RT, London, UK). Surface images were acquired prior to every subsequent setup procedure. EPID acquisition was repeated when errors > 5 mm were reported. RESULTS: The mean random and systematic errors were 1.2 +/- 2.3 mm and 0.3 +/- 3.0 mm along the X axis, 0.0 +/- 1.4 mm and 0.5 +/- 2.0 mm along the Y axis, and 2.0 +/- 1.8 mm and -0.7 +/- 2.4 mm along the Z axis respectively. The positioning error detected by AlignRT along the 3 axes X, Y, and Z exceeded the value of 5 mm in 14.1%, 2.0%, and 5.1% measurements and the value of 3 mm in 36.9%, 13.6% and 27.8% measurements, respectively. Correlation factors calculated by linear regression between the errors measured by AlignRT and EPID ranged from 0.77 to 0.92 with a mean of 0.85 and SD of 0.13. The setup measurements by surface imaging are highly reproducible and correlate with the setup errors detected by EPID. CONCLUSION: Surface image registration system appears to be a simple, fast, non-invasive, and reproducible method to analyze the set-up alignment in 3DCRT of prostate cancer patients.


Asunto(s)
Neoplasias de la Próstata/radioterapia , Planificación de la Radioterapia Asistida por Computador/métodos , Radioterapia Conformacional/métodos , Anciano , Estudios de Cohortes , Simulación por Computador , Humanos , Procesamiento de Imagen Asistido por Computador/instrumentación , Procesamiento de Imagen Asistido por Computador/métodos , Masculino , Persona de Mediana Edad , Planificación de Atención al Paciente , Neoplasias de la Próstata/patología , Planificación de la Radioterapia Asistida por Computador/instrumentación , Reproducibilidad de los Resultados , Programas Informáticos , Carga Tumoral
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA