Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 15 de 15
Filtrar
1.
Clin Radiol ; 71(10): 960-971, 2016 Oct.
Artículo en Inglés | MEDLINE | ID: mdl-27450408

RESUMEN

Longitudinal extensive transverse myelitis (LETM) is defined as an intramedullary spinal cord T2 signal abnormality extending craniocaudally over at least three vertebral bodies on an MRI study. Timely and appropriate diagnosis greatly facilitates patient management. The radiologist should review the relevant clinical information and determine the patient demographics and acuity of symptoms. Herein, we review the spectrum of diseases causing LETM and propose interpretation to guide the radiologist when presented with the MRI finding of LETM.


Asunto(s)
Encéfalo/diagnóstico por imagen , Imagen por Resonancia Magnética/métodos , Mielitis Transversa/diagnóstico por imagen , Mielitis Transversa/terapia , Médula Espinal/diagnóstico por imagen , Encéfalo/patología , Humanos , Mielitis Transversa/patología , Médula Espinal/patología
2.
AJNR Am J Neuroradiol ; 43(6): 837-843, 2022 06.
Artículo en Inglés | MEDLINE | ID: mdl-35618420

RESUMEN

BACKGROUND AND PURPOSE: 3D intracranial vessel wall MRI techniques are time consuming and prone to artifacts, especially flow artifacts. Our aim was to compare the image quality of accelerated and flow-suppressed 3D intracranial vessel wall MR imaging techniques relative to conventional acquisitions. MATERIALS AND METHODS: Consecutive patients undergoing MR imaging had conventional postcontrast 3D T1-sampling perfection with application-optimized contrasts by using different flip angle evolution (SPACE) and either postcontrast delay alternating with nutation for tailored excitation (DANTE) flow-suppressed or DANTE-controlled aliasing in parallel imaging results in higher acceleration (CAIPI) flow-suppressed and accelerated T1-SPACE sequences performed. The sequences were evaluated using 4- or 5-point Likert scales for overall image quality, SNR, extent/severity of artifacts, motion, blood suppression, sharpness, and lesion assessment. Quantitative assessment of lumen and wall-to-lumen contrast ratios was performed. RESULTS: Eighty-nine patients were included. T1-DANTE-SPACE had significantly better qualitative ratings relative to T1-SPACE for image quality, SNR, artifact impact, arterial and venous suppression, and lesion assessment (P < .001 for each, respectively), with the exception of motion (P = .16). T1-DANTE-CAIPI-SPACE had significantly better image quality, lesion assessment, arterial and venous blood suppression, less artifact impact, and less motion compared with T1-SPACE (P < .001 for each, respectively). The SNR was higher with T1-SPACE compared with T1-DANTE-CAIPI-SPACE (P < .001). T1-DANTE-CAIPI-SPACE showed significantly worse lumen (P = .005) and wall-to-lumen contrast ratios (P = .001) compared with T1-SPACE, without a significant difference between T1-SPACE and T1-DANTE-SPACE. T1-DANTE-CAIPI-SPACE scan time was 5:11 minutes compared with 8:08 and 8:41 minutes for conventional T1-SPACE and T1-DANTE-SPACE, respectively. CONCLUSIONS: Accelerated postcontrast T1-DANTE-CAIPI-SPACE had fewer image artifacts, less motion, improved blood suppression, and a shorter scan time, but lower qualitative and quantitative SNR ratings relative to conventional T1-SPACE intracranial vessel wall MR imaging. Postcontrast T1-DANTE-SPACE had superior SNR, blood suppression, higher image quality, and fewer image artifacts, but slightly longer scan times relative to T1-SPACE.


Asunto(s)
Imagenología Tridimensional , Imagen por Resonancia Magnética , Aceleración , Artefactos , Humanos , Imagen por Resonancia Magnética/métodos , Relación Señal-Ruido
3.
AJNR Am J Neuroradiol ; 43(3): 388-393, 2022 03.
Artículo en Inglés | MEDLINE | ID: mdl-35177549

RESUMEN

BACKGROUND AND PURPOSE: Contrast curve truncation in CTP protocols may introduce errors. We sought to identify risk factors and design a protocol to avoid truncation while limiting radiation. MATERIALS AND METHODS: In an initial fixed-timing cohort, patients underwent a 65-second CTP with 2-second delay postcontrast injection. Multivariable analysis identified factors associated with truncation. A later case-specific cohort underwent either the original protocol or a low cardiac output protocol with a 7-second delay and 75-second scanning window, with selection determined by CTA test-dose enhancement upswing delay. Time-density curves were assessed for truncation and compared between the 2 groups, and the radiation dose was evaluated. RESULTS: From September 2017 through May 2018, one hundred fifty-three patients underwent the standard fixed-timing protocol. Age (OR, 1.82/10-year increase; P = .019), reduced left ventricle ejection fraction (OR, 9.23; P = .001), and hypertension (OR, 0.32; P = .06) were independently associated with truncation in an exploratory multivariable model. From May 2018 through April 2019, one hundred fifty-seven patients underwent either the standard (72 patients) or low cardiac output protocol (85 patients). The fixed-timing cohort had 15 truncations (9.8%) versus 4 in the case-specific cohort (2.5%; P = .009). If the low cardiac output protocol were applied to those with >10.6% predicted risk of truncation based on age, left ventricle ejection fraction, and hypertension, the number of truncations would have decreased from 15 to 4 in the fixed-timing cohort. CONCLUSIONS: Older age, left ventricle ejection fraction, and the absence of hypertension increase the risk of time-density curve truncation. However, a CTA test-dose-directed case-specific protocol can reduce truncation to ensure accurate data while mitigating radiation dose increases.


Asunto(s)
Hipertensión , Accidente Cerebrovascular , Humanos , Gasto Cardíaco Bajo , Angiografía Cerebral/métodos , Programas Informáticos , Accidente Cerebrovascular/diagnóstico por imagen , Tomografía Computarizada por Rayos X/métodos
4.
AJNR Am J Neuroradiol ; 43(7): 951-957, 2022 07.
Artículo en Inglés | MEDLINE | ID: mdl-35710122

RESUMEN

BACKGROUND AND PURPOSE: Intracranial vessel wall MR imaging is an emerging technique for intracranial vasculopathy assessment. Our aim was to investigate intracranial vessel wall MR imaging use by the American Society of Neuroradiology (ASNR) members at their home institutions, including indications and barriers to implementation. MATERIALS AND METHODS: The ASNR Vessel Wall Imaging Study Group survey on vessel wall MR imaging use, frequency, applications, MR imaging systems and field strength used, protocol development approaches, vendor engagement, reasons for not using vessel wall MR imaging, ordering-provider interest, and impact on clinical care, was distributed to the ASNR membership between April 2 and August 30, 2019. RESULTS: There were 532 responses; 79 were excluded due to nonresponse and 42 due to redundant institutional responses, leaving 411 responses. Fifty-two percent indicated that their institution performs vessel wall MR imaging, with 71.5% performed at least 1-2 times/month, most frequently on 3T MR imaging, and 87.7% using 3D sequences. Protocols most commonly included were T1-weighted pre- and postcontrast and TOF-MRA; 60.6% had limited contributions from vendors or were still in protocol development. Vasculopathy differentiation (94.4%), cryptogenic stroke (41.3%), aneurysm (38.0%), and atherosclerosis (37.6%) evaluation were the most common indications. For those not performing vessel wall MR imaging, interpretation (53.1%) or technical (46.4%) expertise, knowledge of applications (50.5%), or limitations of clinician (56.7%) or radiologist (49.0%) interest were the most common reasons. If technical/expertise obstacles were overcome, 56.4% of those not performing vessel wall MR imaging indicated that they would perform it. Ordering providers most frequently inquiring about vessel wall MR imaging were from stroke neurology (56.5%) and neurosurgery (25.1%), while 34.3% indicated that no providers had inquired. CONCLUSIONS: More than 50% of neuroradiology groups use vessel wall MR imaging for intracranial vasculopathy characterization and differentiation, emphasizing the need for additional technical and educational support, especially as clinical vessel wall MR imaging implementation continues to grow.


Asunto(s)
Trastornos Cerebrovasculares , Accidente Cerebrovascular Isquémico , Accidente Cerebrovascular , Humanos , Angiografía por Resonancia Magnética/métodos , Imagen por Resonancia Magnética/métodos , Encuestas y Cuestionarios , Estados Unidos
5.
AJNR Am J Neuroradiol ; 43(12): 1756-1761, 2022 12.
Artículo en Inglés | MEDLINE | ID: mdl-36423951

RESUMEN

BACKGROUND AND PURPOSE: Extracranial vessel wall MRI (EC-VWI) contributes to vasculopathy characterization. This survey study investigated EC-VWI adoption by American Society of Neuroradiology (ASNR) members and indications and barriers to implementation. MATERIALS AND METHODS: The ASNR Vessel Wall Imaging Study Group survey on EC-VWI use, frequency, applications, MR imaging systems and field strength used, protocol development approaches, vendor engagement, reasons for not using EC-VWI, ordering provider interest, and impact on clinical care was distributed to the ASNR membership between April 2, 2019, to August 30, 2019. RESULTS: There were 532 responses; 79 were excluded due to minimal, incomplete response and 42 due to redundant institutional responses, leaving 411 responses. Twenty-six percent indicated that their institution performed EC-VWI, with 66.3% performing it ≤1-2 times per month, most frequently on 3T MR imaging, with most using combined 3D and 2D protocols. Protocols most commonly included pre- and postcontrast T1-weighted imaging, TOF-MRA, and contrast-enhanced MRA. Inflammatory vasculopathy (63.3%), plaque vulnerability assessments (61.1%), intraplaque hemorrhage (61.1%), and dissection-detection/characterization (51.1%) were the most frequent applications. For those not performing EC-VWI, the reasons were a lack of ordering provider interest (63.9%), lack of radiologist time/interest (47.5%) or technical support (41.4%) for protocol development, and limited interpretation experience (44.9%) and knowledge of clinical applications (43.7%). Reasons given by 46.9% were that no providers approached radiology with interest in EC-VWI. If barriers were overcome, 51.1% of those not performing EC-VWI indicated they would perform it, and 40.6% were unsure; 48.6% did not think that EC-VWI had impacted patient management at their institution. CONCLUSIONS: Only 26% of neuroradiology groups performed EC-VWI, most commonly due to limited clinician interest. Improved provider and radiologist education, protocols, processing techniques, technical support, and validation trials could increase adoption.


Asunto(s)
Angiografía por Resonancia Magnética , Enfermedades Vasculares , Humanos , Angiografía por Resonancia Magnética/métodos , Imagenología Tridimensional , Imagen por Resonancia Magnética , Arterias Carótidas/diagnóstico por imagen
6.
AJNR Am J Neuroradiol ; 40(1): 92-98, 2019 01.
Artículo en Inglés | MEDLINE | ID: mdl-30523142

RESUMEN

BACKGROUND AND PURPOSE: Compressed sensing-sensitivity encoding is a promising MR imaging acceleration technique. This study compares the image quality of compressed sensing-sensitivity encoding accelerated imaging with conventional MR imaging sequences. MATERIALS AND METHODS: Patients with known, treated, or suspected brain tumors underwent compressed sensing-sensitivity encoding accelerated 3D T1-echo-spoiled gradient echo or 3D T2-FLAIR sequences in addition to the corresponding conventional acquisition as part of their clinical brain MR imaging. Two neuroradiologists blinded to sequence and patient information independently evaluated both the accelerated and corresponding conventional acquisitions. The sequences were evaluated on 4- or 5-point Likert scales for overall image quality, SNR, extent/severity of artifacts, and gray-white junction and lesion boundary sharpness. SNR and contrast-to-noise ratio values were compared. RESULTS: Sixty-six patients were included in the study. For T1-echo-spoiled gradient echo, image quality in all 5 metrics was slightly better for compressed sensing-sensitivity encoding than conventional images on average, though it was not statistically significant, and the lower bounds of the 95% confidence intervals indicated that compressed sensing-sensitivity encoding image quality was within 10% of conventional imaging. For T2-FLAIR, image quality of the compressed sensing-sensitivity encoding images was within 10% of the conventional images on average for 3 of 5 metrics. The compressed sensing-sensitivity encoding images had somewhat more artifacts (P = .068) and less gray-white matter sharpness (P = .36) than the conventional images, though neither difference was significant. There was no significant difference in the SNR and contrast-to-noise ratio. There was 25% and 35% scan-time reduction with compressed sensing-sensitivity encoding for FLAIR and echo-spoiled gradient echo sequences, respectively. CONCLUSIONS: Compressed sensing-sensitivity encoding accelerated 3D T1-echo-spoiled gradient echo and T2-FLAIR sequences of the brain show image quality similar to that of standard acquisitions with reduced scan time. Compressed sensing-sensitivity encoding may reduce scan time without sacrificing image quality.


Asunto(s)
Encéfalo/diagnóstico por imagen , Compresión de Datos/métodos , Imagenología Tridimensional/métodos , Imagen por Resonancia Magnética/métodos , Neuroimagen/métodos , Adulto , Artefactos , Encéfalo/patología , Femenino , Humanos , Procesamiento de Imagen Asistido por Computador/métodos , Masculino , Persona de Mediana Edad
7.
AJNR Am J Neuroradiol ; 39(2): 362-368, 2018 Feb.
Artículo en Inglés | MEDLINE | ID: mdl-29242364

RESUMEN

BACKGROUND AND PURPOSE: Uniform complete fat suppression is essential for identification and characterization of most head and pathology. Our aim was to compare the multipoint Dixon turbo spin-echo fat-suppression technique with 2 different fat-suppression techniques, including a hybrid spectral presaturation with inversion recovery technique and an inversion recovery STIR technique, in head and neck fat-suppression MR imaging. MATERIALS AND METHODS: Head and neck MR imaging datasets of 72 consecutive patients were retrospectively reviewed. All patients were divided into 2 groups based on the type of fat-suppression techniques used (group A: STIR and spectral presaturation with inversion recovery gadolinium-T1WI; group B: multipoint Dixon T2 TSE and multipoint Dixon gadolinium-T1WI TSE). Objective and subjective image quality and scan acquisition times were assessed and compared between multipoint Dixon T2 TSE versus STIR and multipoint Dixon gadolinium-T1WI TSE versus spectral presaturation with inversion recovery gadolinium-T1WI using the Mann-Whitney U test. RESULTS: A total of 64 patients were enrolled in the study (group A, n = 33 and group B, n = 31). Signal intensity ratios were significantly higher for multipoint Dixon T2 and gadolinium-T1WI techniques compared with STIR (P < .001) and spectral presaturation with inversion recovery gadolinium-T1WI (P < .001), respectively. Two independent blinded readers revealed that multipoint Dixon T2 and gadolinium-T1WI techniques had significantly higher overall image quality (P = .022 and P < .001) and fat-suppression grades (P < .013 and P < .001 across 3 different regions) than STIR and spectral presaturation with inversion recovery gadolinium-T1WI, respectively. The scan acquisition time was relatively short for the multipoint Dixon technique (2 minutes versus 4 minutes 56 seconds for the T2-weighted sequence and 2 minutes versus 3 minutes for the gadolinium-T1WI sequence). CONCLUSIONS: The multipoint Dixon technique offers better image quality and uniform fat suppression at a shorter scan time compared with STIR and spectral presaturation with inversion recovery gadolinium-T1WI techniques.


Asunto(s)
Tejido Adiposo/diagnóstico por imagen , Cabeza/diagnóstico por imagen , Interpretación de Imagen Asistida por Computador/métodos , Imagen por Resonancia Magnética/métodos , Cuello/diagnóstico por imagen , Adulto , Anciano , Femenino , Humanos , Masculino , Persona de Mediana Edad , Estudios Retrospectivos
8.
AJNR Am J Neuroradiol ; 39(2): E9-E31, 2018 02.
Artículo en Inglés | MEDLINE | ID: mdl-29326139

RESUMEN

Identification of carotid artery atherosclerosis is conventionally based on measurements of luminal stenosis and surface irregularities using in vivo imaging techniques including sonography, CT and MR angiography, and digital subtraction angiography. However, histopathologic studies demonstrate considerable differences between plaques with identical degrees of stenosis and indicate that certain plaque features are associated with increased risk for ischemic events. The ability to look beyond the lumen using highly developed vessel wall imaging methods to identify plaque vulnerable to disruption has prompted an active debate as to whether a paradigm shift is needed to move away from relying on measurements of luminal stenosis for gauging the risk of ischemic injury. Further evaluation in randomized clinical trials will help to better define the exact role of plaque imaging in clinical decision-making. However, current carotid vessel wall imaging techniques can be informative. The goal of this article is to present the perspective of the ASNR Vessel Wall Imaging Study Group as it relates to the current status of arterial wall imaging in carotid artery disease.


Asunto(s)
Arterias Carótidas/diagnóstico por imagen , Estenosis Carotídea/diagnóstico por imagen , Túnica Íntima/diagnóstico por imagen , Túnica Media/diagnóstico por imagen , Anciano , Angiografía de Substracción Digital , Aterosclerosis/patología , Arterias Carótidas/patología , Estenosis Carotídea/patología , Consenso , Humanos , Masculino , Túnica Íntima/patología , Túnica Media/patología , Ultrasonografía , Estados Unidos
10.
AJNR Am J Neuroradiol ; 38(10): 2015-2020, 2017 Oct.
Artículo en Inglés | MEDLINE | ID: mdl-28818826

RESUMEN

BACKGROUND AND PURPOSE: DTI is a tool for microstructural spinal cord injury evaluation. This study evaluated the reproducibility of a semiautomated segmentation algorithm of spinal cord DTI. MATERIALS AND METHODS: Forty-two consecutive patients undergoing acute trauma cervical spine MR imaging underwent 2 axial DTI scans in addition to their clinical scan. The datasets were put through a semiautomated probabilistic segmentation algorithm that selected white matter, gray matter, and 24 individual white matter tracts. Regional and white matter tract volume, fractional anisotropy, and mean diffusivity values were calculated. Two readers performed the nonautomated steps to evaluate interreader reproducibility. The coefficient of variation and intraclass correlation coefficient were used to assess test-retest and interreader reproducibility. RESULTS: Of 42 patients, 30 had useable data. Test-retest reproducibility of fractional anisotropy was high for white matter as a whole (coefficient of variation, 3.8%; intraclass correlation coefficient, 0.93). Test-retest coefficient-of-variation ranged from 8.0%-18.2% and intraclass correlation coefficients from 0.47-0.80 across individual white matter tracts. Mean diffusivity metrics also had high test-retest reproducibility (white matter: coefficient-of-variation, 5.6%; intraclass correlation coefficient, 0.86) with coefficients of variation from 11.6%-18.3% and intraclass correlation coefficients from 0.57-0.74 across individual tracts, with better agreement for larger tracts. The coefficients of variation of fractional anisotropy and mean diffusivity both had significant negative relationships with white matter volume (26%-27% decrease for each doubling of white matter volume, P < .01). CONCLUSIONS: DTI spinal cord segmentation is reproducible in the setting of acute spine trauma, specifically for larger white matter tracts and total white or gray matter.


Asunto(s)
Atlas como Asunto , Vértebras Cervicales/diagnóstico por imagen , Vértebras Cervicales/lesiones , Imagen de Difusión Tensora/métodos , Traumatismos Vertebrales/diagnóstico por imagen , Adolescente , Adulto , Anciano , Anisotropía , Femenino , Sustancia Gris/diagnóstico por imagen , Humanos , Procesamiento de Imagen Asistido por Computador , Masculino , Persona de Mediana Edad , Variaciones Dependientes del Observador , Tractos Piramidales/diagnóstico por imagen , Reproducibilidad de los Resultados , Sustancia Blanca/diagnóstico por imagen , Adulto Joven
11.
AJNR Am J Neuroradiol ; 38(2): 218-229, 2017 Feb.
Artículo en Inglés | MEDLINE | ID: mdl-27469212

RESUMEN

Intracranial vessel wall MR imaging is an adjunct to conventional angiographic imaging with CTA, MRA, or DSA. The technique has multiple potential uses in the context of ischemic stroke and intracranial hemorrhage. There remain gaps in our understanding of intracranial vessel wall MR imaging findings and research is ongoing, but the technique is already used on a clinical basis at many centers. This article, on behalf of the Vessel Wall Imaging Study Group of the American Society of Neuroradiology, provides expert consensus recommendations for current clinical practice.


Asunto(s)
Encéfalo/diagnóstico por imagen , Arterias Cerebrales/diagnóstico por imagen , Imagen por Resonancia Magnética/métodos , Neuroimagen/métodos , Adulto , Femenino , Humanos , Masculino , Persona de Mediana Edad , Estados Unidos
12.
AJNR Am J Neuroradiol ; 37(8): 1561-6, 2016 Aug.
Artículo en Inglés | MEDLINE | ID: mdl-27056424

RESUMEN

BACKGROUND AND PURPOSE: Conventional MR imaging of the cervical spinal cord in MS is challenged by numerous artifacts and interreader variability in lesion counts. This study compares the relatively novel WM-suppressed T1 inversion recovery sequence with STIR and proton density-weighted TSE sequences in the evaluation of cervical cord lesions in patients with MS. MATERIALS AND METHODS: Retrospective blinded analysis of cervical cord MR imaging examinations of 50 patients with MS was performed by 2 neuroradiologists. In each patient, the number of focal lesions and overall lesion conspicuity were measured in the STIR/proton density-weighted TSE and WM-suppressed T1 inversion recovery sequence groups. Independent side-by-side comparison was performed to categorize the discrepant lesions as either "definite" or "spurious." Lesion contrast ratio and edge sharpness were independently calculated in each sequence. RESULTS: Substantial interreader agreement was noted on the WM-suppressed T1 inversion recovery sequence (κ = 0.82) compared with STIR/proton density-weighted TSE (κ = 0.52). Average lesion conspicuity was better on the WM-suppressed T1 inversion recovery sequence (conspicuity of 3.1/5.0 versus 3.7/5.0, P < .01, in the WM-suppressed T1 inversion recovery sequence versus STIR/proton density-weighted TSE, respectively). Spurious lesions were more common on STIR/proton density-weighted TSE than on the WM-suppressed T1 inversion recovery sequence (23 and 30 versus 3 and 4 by readers 1 and 2, respectively; P < .01). More "definite" lesions were missed on STIR/proton density-weighted TSE compared with the WM-suppressed T1 inversion recovery sequence (37 and 38 versus 3 and 6 by readers 1 and 2, respectively). Lesion contrast ratio and edge sharpness were highest on the WM-suppressed T1 inversion recovery sequence. CONCLUSIONS: There is better interreader consistency in the lesion count on the WM-suppressed T1 inversion recovery sequence compared with STIR/proton density-weighted TSE sequences. The focal cord lesions are visualized with better conspicuity due to better contrast ratio and edge sharpness. There are fewer spurious lesions on the WM-suppressed T1 inversion recovery sequence compared with STIR/proton density-weighted TSE. The WM-suppressed T1 inversion recovery sequence could potentially be substituted for either STIR or proton density-weighted TSE sequences in routine clinical protocols.


Asunto(s)
Artefactos , Médula Cervical/diagnóstico por imagen , Imagen por Resonancia Magnética/métodos , Esclerosis Múltiple/diagnóstico por imagen , Neuroimagen/métodos , Adulto , Anciano , Médula Cervical/patología , Femenino , Humanos , Masculino , Persona de Mediana Edad , Esclerosis Múltiple/patología , Estudios Retrospectivos , Sustancia Blanca/diagnóstico por imagen , Sustancia Blanca/patología
13.
AJNR Am J Neuroradiol ; 36(9): 1580-8, 2015 Sep.
Artículo en Inglés | MEDLINE | ID: mdl-25614476

RESUMEN

The diagnostic evaluation of a patient with reversible cerebral vasoconstriction syndrome integrates clinical, laboratory, and radiologic findings. Imaging plays an important role by confirming the presence of cerebral vasoconstriction; monitoring potential complications such as ischemic stroke; and suggesting alternative diagnoses, including CNS vasculitis and aneurysmal subarachnoid hemorrhage. Noninvasive vascular imaging, including transcranial Doppler sonography and MR angiography, has played an increasingly important role in this regard, though conventional angiography remains the criterion standard for the evaluation of cerebral artery vasoconstriction. Newer imaging techniques, including high-resolution vessel wall imaging, may help in the future to better discriminate reversible cerebral vasoconstriction syndrome from primary angiitis of the CNS, an important clinical distinction.


Asunto(s)
Neuroimagen/métodos , Vasoespasmo Intracraneal/diagnóstico , Diagnóstico Diferencial , Humanos , Masculino
14.
AJNR Am J Neuroradiol ; 36(8): 1392-9, 2015 Aug.
Artículo en Inglés | MEDLINE | ID: mdl-25593203

RESUMEN

Reversible cerebral vasoconstriction syndrome is a clinical and radiologic syndrome that represents a common presentation of a diverse group of disorders. The syndrome is characterized by thunderclap headache and reversible vasoconstriction of cerebral arteries, which can either be spontaneous or related to an exogenous trigger. The pathophysiology of reversible cerebral vasoconstriction syndrome is unknown, though alterations in cerebral vascular tone are thought to be a key underlying mechanism. The syndrome typically follows a benign course; however, reversible cerebral vasoconstriction syndrome may result in permanent disability or death in a small minority of patients secondary to complications such as ischemic stroke or intracranial hemorrhage.


Asunto(s)
Enfermedades Arteriales Cerebrales/fisiopatología , Arterias Cerebrales/fisiopatología , Cefaleas Primarias/etiología , Cefaleas Primarias/fisiopatología , Vasoconstricción , Adulto , Encéfalo/fisiopatología , Enfermedades Arteriales Cerebrales/diagnóstico , Enfermedades Arteriales Cerebrales/terapia , Femenino , Cefaleas Primarias/diagnóstico , Humanos , Hemorragias Intracraneales/etiología , Pronóstico , Accidente Cerebrovascular/etiología , Síndrome , Vasoespasmo Intracraneal/etiología
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA