Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 14 de 14
Filtrar
1.
Arch Biochem Biophys ; 502(2): 81-8, 2010 Oct 15.
Artículo en Inglés | MEDLINE | ID: mdl-20692227

RESUMEN

We identified a gene encoding a soluble quinoprotein glucose dehydrogenase homologue in the hyperthermophilic archaeon Pyrobaculum aerophilum. The gene was overexpressed in Escherichia coli, after which its product was purified and characterized. The enzyme was extremely thermostable, and the activity of the pyrroloquinoline quinone (PQQ)-bound holoenzyme was not lost after incubation at 100 degrees C for 10 min. The crystal structure of the enzyme was determined in both the apoform and as the PQQ-bound holoenzyme. The overall fold of the P. aerophilum enzyme showed significant similarity to that of soluble quinoprotein aldose sugar dehydrogenase (Asd) from E. coli. However, clear topological differences were observed in the two long loops around the PQQ-binding sites of the two enzymes. Structural comparison revealed that the hyperthermostability of the P. aerophilum enzyme is likely attributable to the presence of an extensive aromatic pair network located around a beta-sheet involving N- and C-terminal beta-strands.


Asunto(s)
Glucosa Deshidrogenasas/química , Cofactor PQQ/metabolismo , Pyrobaculum/enzimología , Archaea/genética , Sitios de Unión , Carbohidratos , Catálisis , Escherichia coli/enzimología , Escherichia coli/genética , Oxidorreductasas
2.
Nutrition ; 25(1): 6-10, 2009 Jan.
Artículo en Inglés | MEDLINE | ID: mdl-18723324

RESUMEN

OBJECTIVE: We investigated the prevalence of anemia and deficiency in trace elements in adolescent girls living in rural Vietnam. METHODS: Two hundred forty-five adolescent girls 11-17 y of age from three schools in rural province of Ha Nam, Vietnam, were assessed. RESULTS: The prevalence of anemia was 20.4%. The incidences of low serum selenium (Se), zinc, and copper in subjects were 15.9%, 26.5%, and 4.1%, respectively. The parameter significantly associated with anemia was the low serum levels of Se and vice versa (odds ratio [OR] 5.36, 95% confidence interval [CI] 2.57-11.18, P < 0.0001). Other risk factors for anemia were a body mass index <17.00 kg/m(2) (OR 2.72, 95% CI 1.37-5.37, P = 0.004) and years of age (OR 1.35, 95% CI 1.14-1.59, P < 0.001). A body mass index <17.00 kg/m(2) (OR 2.65, 95% CI 1.25-5.61, P = 0.011) was also found to be a risk factor for low serum Se. CONCLUSION: The findings of the present study demonstrate that low serum Se is independently associated with anemia in adolescent girls living in rural Vietnam. Interventions are required to gain insight into the potential role of Se on prevention and control of anemia.


Asunto(s)
Anemia Ferropénica/sangre , Anemia Ferropénica/epidemiología , Evaluación Nutricional , Estado Nutricional , Selenio/sangre , Selenio/deficiencia , Adolescente , Índice de Masa Corporal , Niño , Intervalos de Confianza , Cobre/sangre , Cobre/deficiencia , Estudios Transversales , Femenino , Humanos , Oportunidad Relativa , Prevalencia , Factores de Riesgo , Salud Rural , Vietnam/epidemiología , Zinc/sangre , Zinc/deficiencia
3.
Anal Sci ; 24(6): 791-4, 2008 Jun.
Artículo en Inglés | MEDLINE | ID: mdl-18544871

RESUMEN

Both (206)Pb-labeled trimethyllead (TML) and triethyllead (TEL) were synthesized from (206)Pb-enriched metallic Pb certified reference material (NIST SRM 983) and iodomethane or iodoethane through a one-process reaction in a closed system using centrifuge tubes, respectively. Organolead compounds in an urban dust reference material (BCR CRM 605) were extracted with an acetic acid/methanol (1:1) solution, which was mechanically shaken for 24 h. After adjusting the pH of the extracted solution to pH 5, the extracted organolead compounds were derivatized by tetrabutylammonium tetrabutylborate (TATB) and measured with GC-ICPMS. The analytical results of TML and TEL for BCR CRM 605 were 8.22 +/- 0.04 microg kg(-1) (mean +/- standard deviation, n = 3) and 1.12 +/- 0.06 microg kg(-1), respectively. The analytical results of TML agreed well with the certified value (7.9 +/- 1.2 microg kg(-1)).

4.
J Nutr Sci Vitaminol (Tokyo) ; 54(6): 454-9, 2008 Dec.
Artículo en Inglés | MEDLINE | ID: mdl-19155583

RESUMEN

A cross-sectional study of 292 primary school children was conducted in rural Vietnam to investigate the relationship among micronutrient deficiencies, and other risk factors for anemia. Serum levels of iron, copper, zinc, selenium and magnesium were determined by inductively coupled plasma mass spectrometry and that of retinol by high performance liquid chromatography. Hemoglobin concentration in whole blood was measured by the cyanmethemoglobin method. The incidence of low serum zinc, selenium, magnesium, and copper in the children was 91.4, 75.6, 59.5, and 8.6%, respectively. Forty-five percent of the children were anemic and 11.3% suffered from vitamin A deficiency. A parameter significant associated with anemia was low serum selenium and vice versa (OR 1.85, 95% CI 1.06-3.24, p<0.05). Other factors associated with anemia were serum retinol <1.05 micromol/L (OR 2.05, 95% CI 1.25-3.36, p<0.01), and age in years (OR 1.59, 95% CI 1.16-2.18, p<0.01). The study showed that low selenium is associated with anemia among school children in Vietnam. Interventions are required to gain insight into the potential role of selenium on prevention and control of anemia.


Asunto(s)
Anemia/epidemiología , Trastornos de la Nutrición del Niño/epidemiología , Hemoglobinas/análisis , Selenio/deficiencia , Anemia/etiología , Niño , Trastornos de la Nutrición del Niño/complicaciones , Cobre/sangre , Cobre/deficiencia , Estudios Transversales , Enfermedades Carenciales/complicaciones , Femenino , Humanos , Hierro/sangre , Deficiencias de Hierro , Deficiencia de Magnesio/sangre , Masculino , Prevalencia , Selenio/sangre , Vietnam/epidemiología , Deficiencia de Vitamina A/sangre , Deficiencia de Vitamina A/complicaciones , Deficiencia de Vitamina A/epidemiología , Zinc/sangre , Zinc/deficiencia
5.
Anal Sci ; 23(1): 59-63, 2007 Jan.
Artículo en Inglés | MEDLINE | ID: mdl-17213625

RESUMEN

A glucose sensor was developed by electrocopolymerization using pyrroles containing a tris-bipyridine (bpy) osmium complex (Os-py), pyrrole (py), pyrrole propanoic acid (PPA) and glucose oxidase (GOx) to improve the key performance characteristics, such as the sensitivity, selectivity, and long-term stability. Tris-bipyridine osmium pyrrole complexes with four different methylene moieties were utilized to correlate the methylene length with the glucose sensor performance. The electrocatalytic response of glucose was clearly observed at electrodes modified with Os-py, except for the electrode immobilized with the Os-py complex containing the shortest methylene moiety. The current response to glucose increased up to a concentration of 100 mmol dm(-3). The electrocatalytic response to glucose at the [Os(bpy)(2)(py(6)-bpy)](2+/3+)/py/PPA/GOx electrode was stable for more than 100 days. Dissolved oxygen and potential interference compounds (ascorbic acid, uric acid, and acetaminophen) minimally perturbed the current response to glucose at the [Os(DM-bpy)(2)(py(6)-bpy)](2+/3+)/py/PPA/GOx electrode. Based on these results, a longer methylene moiety appears to improve the performance characteristics of a glucose sensor fabricated via the electropolymerization of tris-bipyridine osmium pyrrole complexes.


Asunto(s)
2,2'-Dipiridil/análogos & derivados , Glucosa/análisis , Compuestos Organometálicos/química , Pirroles/química , 2,2'-Dipiridil/química , Animales , Glucemia/análisis , Calibración , Catálisis , Bovinos , Electroquímica , Electrodos , Indicadores y Reactivos , Polímeros/síntesis química
6.
Anal Sci ; 22(7): 1021-4, 2006 Jul.
Artículo en Inglés | MEDLINE | ID: mdl-16837757

RESUMEN

We present a new multielement masking method using magnesium hydroxide coprecipitation for the selective determination of Pb by differential pulse anodic stripping voltammetry (DPASV). The recovery of Pb in the masking method was over 95%, while interfering ions (Cd(2+), Co(2+), Cu(2+), Fe(3+), Mn(2+), and Ni(2+)) could be removed at 100% from the analytical sample. A linear regression was obtained in the Pb concentration from 10 to 1000 microg kg(-1) in the existence of 100 microg kg(-1) of the interfering ions. When this method was applied to the determination of Pb in a natural water-standard reference material (NIST 1640), the determined value for Pb in this work (25.4 +/- 4.1 microg kg(-1)) almost agreed with the certified value (27.89 +/- 0.14 microg kg(-1)).

7.
Biol Trace Elem Res ; 111(1-3): 1-9, 2006.
Artículo en Inglés | MEDLINE | ID: mdl-16943592

RESUMEN

This study was aimed at assessing the serum levels of vitamin A, copper, zinc, selenium, and iron among adult Vietnamese with and without iron-deficiency anemia. Blood was collected from adult Vietnamese living in the midland of northern Vietnam. One hundred twenty-three subjects in the age range 20-60 yr were included in the study. Anemia, where the concentration of hemoglobin in whole blood is less than 120 g/L in females and 130 g/L in males, was found in 30% (37/123) of the study population. The levels of vitamin Aand selenium in the sera of anemic subjects (n = 37) were significantly lower than that in nonanemic group (n = 86). On the other hand, no significant differences were observed in the concentrations of copper and zinc between the two groups. This study was the first to show serum levels of trace elements in adult Vietnamese, providing useful baseline information for further studies.


Asunto(s)
Anemia Ferropénica/sangre , Hierro/sangre , Oligoelementos/sangre , Adulto , Anemia Ferropénica/epidemiología , Cobre/sangre , Estudios Transversales , Femenino , Humanos , Masculino , Persona de Mediana Edad , Selenio/sangre , Vietnam/epidemiología , Vitamina A/sangre , Zinc/sangre
8.
Anal Sci ; 20(7): 1069-73, 2004 Jul.
Artículo en Inglés | MEDLINE | ID: mdl-15293404

RESUMEN

Phase changes between PdO and Pd metal can be directly detected in PdO/CeO2 catalysts supported on chi-Al2O3 by means of in situ high-temperature measurements of X-ray diffraction and FT-IR in relation to the catalytic activity for the methane oxidation of microcrystalline PdO. Reversible changes in the solid phases are observed from PdO to Pd and Pd to PdO under O2-deficient and O2-excess atmospheres, respectively. Nanosizes of PdO and Pd crystallites, the distorted PdO crystal structure along the (110) plane, and also a distorted Pd metal crystal structure along the (200) plane as well as the large surface area elucidate the high catalytic activity for the methane oxidation of PdO/CeO2 catalysts prepared with an atomic ratio of Pd:Ce = 1:1.

9.
Anal Sci ; 26(4): 407-9, 2010.
Artículo en Inglés | MEDLINE | ID: mdl-20410560

RESUMEN

A simple and compact system was developed for the on-site analysis of lead in environmental water samples. The system consisted of a custom-made blue diode as a light source, a liquid core waveguide (LCW) as spectrophotometric cell and a compact UV-visible spectrometer. It weighed within 1.5 kg in total. Lead was detected using a spectrophotometric indicator reagent (TPPS: 5,10,15,20-tetraphenyl-21H,23H-porphinetetrasulfonic acid, disulfuric acid, tetrahydrate) after masking interfering ions by coprecipitation with magnesium hydroxide. With an increase in the length of the LCW cell, the detection limit of lead was almost linearly enhanced, and the linear calibration range was shifted to a lower concentration range. The detection limit of lead by using 100 cm of a LCW cell was 2 nmol dm(-3). The observed value (9.6 +/- 0.4 microg dm(-3)) of lead in a river-water reference material (JSAC 0302-3) with this system was in good agreement with the certified value (9.9 +/- 0.2 microg dm(-3)).


Asunto(s)
Plomo/análisis , Luz , Espectrofotometría Ultravioleta/instrumentación , Espectrofotometría Ultravioleta/métodos , Color , Electrodos , Agua/química
10.
Anal Sci ; 26(3): 395-400, 2010.
Artículo en Inglés | MEDLINE | ID: mdl-20215695

RESUMEN

Airborne particulate matter (PM) collected in Bucharest (Romania) and Tokushima (Japan) was comprehensively characterized through multielemental analysis by ICP-MS to the PM samples. Prior to an elemental characterization of the sample, a multielemental determination method composed of acid digestion (HClO(4)/HNO(3)/HF or H(2)O(2)/HNO(3)/HF) and inductively coupled plasma mass spectrometry/inductively coupled plasma atomic emission spectrometry (ICP-MS/ICP-AES) was established to analyze a certified reference material of vehicle exhaust matter (NIES No. 8) for verifying the method. As the results, 39 elements in the certified reference material could be determined. They were a good agreement with the certified and reference values for HClO(4)/HNO(3)/HF acid digestion. Chalcophile elements, such as cadmium, antimony, and lead in Bucharest showed higher enrichment factors than those in Tokushima.


Asunto(s)
Material Particulado/análisis , Japón , Espectrometría de Masas , Rumanía , Espectrofotometría Atómica
11.
Anal Sci ; 25(7): 919-23, 2009 Jul.
Artículo en Inglés | MEDLINE | ID: mdl-19609033

RESUMEN

Carbon nanotube (CNT) gel, which is composed of a mixture of single-wall CNT, an ionic liquid, and a thermostable D-proline dehydrogenase (D-Pro DH) immobilized electrode was utilized for the determination of D-amino acids (DAAs) in food samples. When a critical comparison with CNT, Ketjen Black (KB), and carbon powder (CP) was also carried out, the CNT/D-Pro DH immobilized electrode showed the highest sensitivity and the lowest detection limit of D-proline. In addition, the CNT/D-Pro DH immobilized electrode was applied to detection of DAAs in rice wine and vinegar samples. The concentrations of DAAs in rice wine and vinegar samples were 0.0210 +/- 0.0001 and 0.55 +/- 0.05 mmol L(-1), respectively.


Asunto(s)
Aminoácidos/análisis , Aminoácidos/química , Técnicas Biosensibles/métodos , Líquidos Iónicos/química , Nanotubos de Carbono/química , Prolina Oxidasa/metabolismo , Ácido Acético/química , Conductividad Eléctrica , Electroquímica , Electrodos , Estabilidad de Enzimas , Enzimas Inmovilizadas/química , Geles , Oryza , Propiedades de Superficie , Temperatura , Vino/análisis
12.
Anal Chim Acta ; 619(2): 215-20, 2008 Jul 07.
Artículo en Inglés | MEDLINE | ID: mdl-18558115

RESUMEN

A novel biosensor for determination of d-amino acids (DAAs) in biological samples by using an electrode based on immobilization of a thermostable d-Proline dehydrogenase (d-Pro DH) within an agar gel membrane was developed. The electrode was simply prepared by spin-coating the agar solution with the d-Pro DH on a glassy carbon (GC) electrode. An electrocatalytic oxidation current of 2,6-dichloroindophenol (DCIP) was observed at -100mV vs. Ag/AgCl with the addition of 5 and 20mmolL(-1)d-proline. The current response and its relative standard deviation were 0.15muA and 7.6% (n=3), respectively, when it was measured in a pH 8.0 phosphate buffer solution containing 10mmolL(-1)d-proline and 0.5mmolL(-1) DCIP at 50 degrees C. The current response of d-proline increased with increase of the temperature of the sample solution up to 70 degrees C. The electrocatalytic response at the d-Pro DH/agar immobilized electrode subsequently maintained for 80 days. Finally, the d-Pro DH/agar immobilized electrode was applied to determination of DAAs in a human urine sample. The determined value of DAAs in the human urine and its R.S.D. were 1.39+/-0.12mmolL(-1) and 8.9% (n=3), respectively.


Asunto(s)
Agar/química , Aminoácidos/química , Aminoácidos/orina , Enzimas Inmovilizadas/metabolismo , Prolina Oxidasa/metabolismo , Aminoácidos/metabolismo , Electroquímica , Electrodos , Geles , Humanos , Reproducibilidad de los Resultados
13.
Asia Pac J Clin Nutr ; 17(1): 48-55, 2008.
Artículo en Inglés | MEDLINE | ID: mdl-18364326

RESUMEN

The prevalence of trace elements deficiencies, vitamin A deficiency, anemia, and their relationships were investigated in a cross sectional study involving 243 children aged from 12 to 72 months in rural Vietnam. Serum levels of copper, zinc, selenium and magnesium were determined by inductively coupled plasma mass spectrometer and that of retinol by high performance liquid chromatography. Hemoglobin concentration in whole blood was measured by the cyanmethemoglobin method. The prevalence of deficiencies in zinc, selenium, magnesium, and copper was 86.9%, 62.3%, 51.9%, and 1.7%, respectively. On the other hand, 55.6% were anemic and 11.3% had vitamin A deficiency. Deficiency in two or more micronutrient was found in 79.4% of the children. Parameters associated significantly with anemia were selenium deficiency (OR 2.80 95% CI 1.63-4.80, p=0.0002) and serum retinol<1.05 micromol/L (OR 1.83, 95% CI 1.10-3.05, p=0.021). Magnesium deficiency (OR 3.09 95% CI 1.36-7.03) was found to be a risk factor for zinc deficiency and vice versa. The results indicate that micronutrient deficiencies are prevalent among preschool children in Vietnam. In addition, the results also demonstrate a strong relationship between selenium deficiency and anemia. Clearly, sustainable strategies are urgently required to overcome the problems in the country.


Asunto(s)
Anemia Ferropénica/epidemiología , Micronutrientes/sangre , Micronutrientes/deficiencia , Estado Nutricional , Población Rural/estadística & datos numéricos , Deficiencia de Vitamina A/epidemiología , Anemia Ferropénica/sangre , Preescolar , Cromatografía Líquida de Alta Presión , Intervalos de Confianza , Estudios Transversales , Femenino , Hemoglobinas/análisis , Humanos , Lactante , Magnesio/sangre , Deficiencia de Magnesio/sangre , Deficiencia de Magnesio/epidemiología , Masculino , Oportunidad Relativa , Prevalencia , Factores de Riesgo , Selenio/sangre , Selenio/deficiencia , Vietnam/epidemiología , Deficiencia de Vitamina A/sangre , Zinc/sangre , Zinc/deficiencia
14.
Anal Chem ; 74(15): 3698-703, 2002 Aug 01.
Artículo en Inglés | MEDLINE | ID: mdl-12175156

RESUMEN

Application of a dipyrido[3,2-a:2',3'-c]phenazine (DPPZ)-type metal complex as an DNA electrochemical probe was studied. The introduction of electron-donating groups (NH2) was effective for controlling the redox potential and binding affinities of the DPPZ-type osmium complex. The [Os(DA-bpy)2DPPZ]2+ complex (DA-bpy; 4,4'-diamino-2,2'-bipyridine) had a lower half-wave potential (E 1/2) of 147 mV (vs Ag/AgCl) and higher binding affinity with DNA (binding constant, K = 3.1 x 10(7) M(-1)) than those of other complexes. With a single-stranded DNA immobilized gold electrode, the hybridization signal (deltaI) of the [Os(DA-bpy)2DPPZ]2+ complex was linear in the concentration range of 1.0 pg mL(-1) - 0.12 microg mL(-1) for the targeted DNA with a regression coefficient of 0.999. The detection limit was 0. 1 pg mL(-1). The 400-bp yAL3 gene was also detected with good sensitivity and selectivity using the [Os(DA-bpy)2DPPZ]2+ complex.


Asunto(s)
Técnicas Biosensibles/métodos , ADN de Cadena Simple , ADN/análisis , Compuestos de Osmio/química , Fenazinas/química , ADN de Cadena Simple/química , Electroquímica , Electrodos/normas , Sondas Moleculares/normas , Hibridación de Ácido Nucleico , Oxidación-Reducción , Sensibilidad y Especificidad
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA