Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 74
Filtrar
Más filtros

Bases de datos
País/Región como asunto
Tipo del documento
Intervalo de año de publicación
1.
Acta Oncol ; 62(2): 134-140, 2023 Feb.
Artículo en Inglés | MEDLINE | ID: mdl-36847433

RESUMEN

BACKGROUND AND PURPOSE: Hippocampus is a central component for neurocognitive function and memory. We investigated the predicted risk of neurocognitive impairment of craniospinal irradiation (CSI) and the deliverability and effects of hippocampal sparing. The risk estimates were derived from published NTCP models. Specifically, we leveraged the estimated benefit of reduced neurocognitive impairment with the risk of reduced tumor control. MATERIAL AND METHODS: For this dose planning study, a total of 504 hippocampal sparing intensity modulated proton therapy (HS-IMPT) plans were generated for 24 pediatric patients whom had previously received CSI. Plans were evaluated with respect to target coverage and homogeneity index to target volumes, maximum and mean dose to OARs. Paired t-tests were used to compare hippocampal mean doses and normal tissue complication probability estimates. RESULTS: The median mean dose to the hippocampus could be reduced from 31.3 GyRBE to 7.3 GyRBE (p < .001), though 20% of these plans were not considered clinically acceptable as they failed one or more acceptance criterion. Reducing the median mean hippocampus dose to 10.6 GyRBE was possible with all plans considered as clinically acceptable treatment plans. By sparing the hippocampus to the lowest dose level, the risk estimation of neurocognitive impairment could be reduced from 89.6%, 62.1% and 51.1% to 41.0% (p < .001), 20.1% (p < .001) and 29.9% (p < .001) for task efficiency, organization and memory, respectively. Estimated tumor control probability was not adversely affected by HS-IMPT, ranging from 78.5 to 80.5% for all plans. CONCLUSIONS: We present estimates of potential clinical benefit in terms of neurocognitive impairment and demonstrate the possibility of considerably reducing neurocognitive adverse effects, minimally compromising target coverage locally using HS-IMPT.


Asunto(s)
Terapia de Protones , Radioterapia de Intensidad Modulada , Humanos , Niño , Protones , Órganos en Riesgo/efectos de la radiación , Planificación de la Radioterapia Asistida por Computador/métodos , Radioterapia de Intensidad Modulada/efectos adversos , Radioterapia de Intensidad Modulada/métodos , Terapia de Protones/efectos adversos , Terapia de Protones/métodos , Hipocampo/efectos de la radiación , Irradiación Craneana/efectos adversos , Irradiación Craneana/métodos , Dosificación Radioterapéutica
2.
Acta Oncol ; 62(4): 391-399, 2023 Apr.
Artículo en Inglés | MEDLINE | ID: mdl-37203198

RESUMEN

INTRODUCTION: Proton radiation therapy (PT) has become a treatment option alongside photon therapy (XRT) for lower-grade gliomas (LGG). In this single-institution retrospective study, we investigate the patient characteristics and treatment outcomes, including pseudo-progression (PsP), for LGG patients selected for PT. METHOD: Adult patients with grade 2-3 glioma consecutively treated with radiotherapy (RT) from May 2012 to December 2019 were retrospectively included in this cohort study. Tumor characteristics and treatment data were collected. The groups treated with PT and XRT were compared regarding treatment characteristics, side effects, occurrence of PsP, and survival outcomes. PsP was defined as new or growing lesions followed by either decrease or stabilization during a 12 month-period with no treatment. RESULTS: Out of 143 patients meeting the inclusion criteria, 44 were treated with PT, 98 with XRT and one with mixed PT + XRT. The patients receiving PT were younger, had a lower tumor grade, more oligodendrogliomas and received a lower mean brain and brainstem dose. PsP was observed in 21 out of 126 patients, with no difference between XRT and PT (p = .38). The rate of fatigue in immediate connection to RT (zero to three months after) was higher for XRT than for PT (p = .016). The PT patients had a significantly better PFS and OS than the XRT patients (p = .025 and .035), but in multivariate analysis radiation modality was non-significant. Higher average dose to both brain and brainstem was associated with inferior PFS and OS (p < .001). Median follow-up time were 69 months and 26 months for XRT and PT patients, respectively. CONCLUSION: Contrary to previous studies, there was no difference in risk of PsP for XRT and PT. PT was associated with lower rates of fatigue <3 months after RT. The superior survival outcomes for PT indicates that the patients with the best prognosis were referred to PT.


Asunto(s)
Neoplasias Encefálicas , Glioma , Terapia de Protones , Adulto , Humanos , Terapia de Protones/efectos adversos , Neoplasias Encefálicas/patología , Estudios Retrospectivos , Estudios de Cohortes , Glioma/radioterapia , Glioma/patología
3.
Oncologist ; 25(3): 210-e422, 2020 03.
Artículo en Inglés | MEDLINE | ID: mdl-32162821

RESUMEN

LESSONS LEARNED: It is possible to plan and treat some patients with stereotactic body radiotherapy (SBRT) in a timely fashion in an acute setting. Advanced and, in some indications, already implemented technologies such as SBRT are difficult to test in a randomized trial. BACKGROUND: Stereotactic body radiotherapy (SBRT) in metastatic spinal cord compression (MSCC) could be an alternative to decompressive surgery followed by fractionated radiotherapy. METHODS: In a randomized, single-institution, noninferiority trial, patients with MSCC were assigned to stereotactic body radiotherapy of 16 Gy in 1 fraction or decompression surgery followed by fractionated radiotherapy of 30 Gy in 10 fractions. Primary endpoint was ability to walk by EQ5D-5L questionnaire. Based on power calculations, 130 patients had to be included to be 89% sure that a 15% difference between the treatment arm and the experimental arm could be detected. RESULTS: Ten patients were accrued in 23 months, with six patients allocated to surgery and four patients to stereotactic body radiotherapy. The trial was closed prematurely because of poor accrual. One patient undergoing surgery and one patient undergoing stereotactic body radiotherapy were unable to walk at 6 weeks. Two patients were not evaluable at 6 weeks. CONCLUSION: A randomized, phase II, clinical trial comparing surgery followed by fractionated radiotherapy or image-guided SBRT of MSCC was initiated. SBRT was shown to be feasible, with three out of four patients retaining walking function. The trial was determined futile as a result of low accrual.


Asunto(s)
Radiocirugia , Compresión de la Médula Espinal , Neoplasias de la Columna Vertebral , Humanos , Radiocirugia/efectos adversos , Compresión de la Médula Espinal/etiología , Compresión de la Médula Espinal/radioterapia , Compresión de la Médula Espinal/cirugía , Neoplasias de la Columna Vertebral/radioterapia , Neoplasias de la Columna Vertebral/cirugía , Resultado del Tratamiento , Caminata
4.
Eur J Nucl Med Mol Imaging ; 46(3): 603-613, 2019 03.
Artículo en Inglés | MEDLINE | ID: mdl-30276440

RESUMEN

BACKGROUND: Recurrence in glioblastoma patients often occur close to the original tumour and indicates that the current treatment is inadequate for local tumour control. In this study, we explored the feasibility of using multi-modality imaging at the time of radiotherapy planning. Specifically, we aimed to identify parameters from pre-treatment PET and MRI with potential to predict tumour recurrence. MATERIALS AND METHODS: Sixteen patients were prospectively recruited and treated according to established guidelines. Multi-parametric imaging with 18F-FET PET/CT and 18F-FDG PET/MR including diffusion and dynamic contrast enhanced perfusion MRI were performed before radiotherapy. Correlations between imaging parameters were calculated. Imaging was related to the voxel-wise outcome at the time of tumour recurrence. Within the radiotherapy target, median differences of imaging parameters in recurring and non-recurring voxels were calculated for contrast-enhancing lesion (CEL), non-enhancing lesion (NEL), and normal appearing grey and white matter. Logistic regression models were created to predict the patient-specific probability of recurrence. The most important parameters were identified using standardized model coefficients. RESULTS: Significant median differences between recurring and non-recurring voxels were observed for FDG, FET, fractional anisotropy, mean diffusivity, mean transit time, extra-vascular, extra-cellular blood volume and permeability derived from scans prior to chemo-radiotherapy. Tissue-specific patterns of voxel-wise correlations were observed. The most pronounced correlations were observed for 18F-FDG- and 18F-FET-uptake in CEL and NEL. Voxel-wise modelling of recurrence probability resulted in area under the receiver operating characteristic curve of 0.77 from scans prior to therapy. Overall, FET proved to be the most important parameter for recurrence prediction. CONCLUSION: Multi-parametric imaging before radiotherapy is feasible and significant differences in imaging parameters between recurring and non-recurring voxels were observed. Combining parameters in a logistic regression model enabled patient-specific maps of recurrence probability, where 18F-FET proved to be most important. This strategy could enable risk-adapted radiotherapy planning.


Asunto(s)
Glioblastoma/diagnóstico por imagen , Imagen por Resonancia Magnética , Tomografía Computarizada por Tomografía de Emisión de Positrones , Adulto , Anciano , Neoplasias Encefálicas/diagnóstico por imagen , Neoplasias Encefálicas/radioterapia , Estudios de Factibilidad , Femenino , Fluorodesoxiglucosa F18 , Glioblastoma/radioterapia , Humanos , Masculino , Persona de Mediana Edad , Probabilidad , Planificación de la Radioterapia Asistida por Computador , Recurrencia , Resultado del Tratamiento
5.
Acta Oncol ; 56(6): 853-859, 2017 Jun.
Artículo en Inglés | MEDLINE | ID: mdl-28464744

RESUMEN

INTRODUCTION: The breath-hold technique inter alia has been suggested to mitigate the detrimental effect of motion on pencil beam scanned (PBS) proton therapy dose distributions. The aim of this study was to evaluate the robustness of incident proton beam angles to day-to-day anatomical variations in breath-hold. MATERIALS AND METHODS: Single field PBS plans at five degrees increments in the transversal plane were made and water-equivalent path lengths (WEPLs) were derived on the planning breath-hold CT (BHCT) for 30 patients diagnosed with locally-advanced non-small cell lung cancer (NSCLC), early stage NSCLC or lung metastasis. Our treatment planning system was subsequently used to recalculate the plans and derive WEPL on a BHCT scan acquired at the end of the treatment. Changes to the V95%, D95 and mean target dose were evaluated. RESULTS: The difference in WEPL as a function of the beam angle was highly patient specific, with a median of 3.3 mm (range: 0.0-41.1 mm). Slightly larger WEPL differences were located around the lateral or lateral anterior/posterior beam angles. Linear models revealed that changes in dose were associated to the changes in WEPL and the tumor baseline shift (p < 0.05). CONCLUSIONS: WEPL changes and tumor baseline shift can serve as reasonable surrogates for dosimetric uncertainty of the target coverage and are well-suited for routine evaluation of plan robustness. The two lateral beam angles are not recommended to use for PBS proton therapy of lung cancer patients treated in breath-hold, due to the poor robustness for several of the patients evaluated.


Asunto(s)
Contencion de la Respiración , Carcinoma de Pulmón de Células no Pequeñas/radioterapia , Neoplasias Pulmonares/radioterapia , Movimiento/efectos de la radiación , Terapia de Protones , Planificación de la Radioterapia Asistida por Computador/métodos , Carcinoma de Pulmón de Células no Pequeñas/diagnóstico por imagen , Estudios de Cohortes , Fraccionamiento de la Dosis de Radiación , Femenino , Tomografía Computarizada Cuatridimensional , Humanos , Procesamiento de Imagen Asistido por Computador/métodos , Neoplasias Pulmonares/diagnóstico por imagen , Masculino , Dosificación Radioterapéutica , Radioterapia de Intensidad Modulada/métodos
6.
Acta Oncol ; 56(3): 415-421, 2017 Mar.
Artículo en Inglés | MEDLINE | ID: mdl-28084862

RESUMEN

BACKGROUND: The purpose of this study was to examine visual outcome, endocrine function and tumor control in a prospective cohort of craniopharyngioma patients, treated with fractionated stereotactic radiation therapy (FSRT). MATERIAL AND METHODS: Sixteen adult patients with craniopharyngiomas were eligible for analysis. They were treated with linear accelerator-based FSRT during 1999-2015. In all cases, diagnosis was confirmed by histological analysis. The prescription dose to the tumor was 54 Gy (median, range 48-54) in 1.8 or 2.0 Gy per fraction, and the maximum radiation dose to the optic nerves and chiasm was 54.2 Gy (median, range 48.6-60.0) for the cohort. Serial ophthalmological and endocrine evaluations and magnetic resonance imaging (MRI) scans were performed at regular intervals. Median follow-up was 3.3 years (range 1.1-14.1), 3.7 years (range 0.8-15.2), and 3.6 years (range 0.7-13.1) for visual outcome, endocrine function, and tumor control, respectively. RESULTS: Visual acuity impairment was present in 10 patients (62.5%) and visual field defects were present in 12 patients (75%) before FSRT. One patient developed radiation-induced optic neuropathy at seven years after FSRT. Thirteen of 16 patients (81.3%) had pituitary deficiency before FSRT, and did not develop further pituitary deficiency after FSRT. Mean tumor volume pre-FSRT was 2.72 cm3 (range 0.20-9.90) and post-FSRT 1.2 cm3 (range 0.00-13.10). Tumor control rate was 81.3% at two, five, and 10 years after FSRT. CONCLUSIONS: FSRT was relatively safe in this prospective cohort of craniopharyngiomas, with only one case of radiation-induced optic neuropathy and no case of new endocrinopathy. Tumor control rate was acceptable.


Asunto(s)
Craneofaringioma/radioterapia , Hipófisis/efectos de la radiación , Hormonas Hipofisarias/metabolismo , Neoplasias Hipofisarias/radioterapia , Radiocirugia/métodos , Visión Ocular/efectos de la radiación , Adolescente , Adulto , Anciano , Craneofaringioma/patología , Fraccionamiento de la Dosis de Radiación , Femenino , Estudios de Seguimiento , Humanos , Masculino , Persona de Mediana Edad , Hipófisis/metabolismo , Hipófisis/fisiología , Neoplasias Hipofisarias/patología , Dosificación Radioterapéutica , Estudios Retrospectivos , Resultado del Tratamiento , Carga Tumoral , Visión Ocular/fisiología , Adulto Joven
7.
Pediatr Blood Cancer ; 63(2): 262-9, 2016 Feb.
Artículo en Inglés | MEDLINE | ID: mdl-26397177

RESUMEN

BACKGROUND: Pediatric cancer patients requiring radiation therapy (RT) have been routinely assessed and referred to proton therapy (PT) at an external institution. The benefit of the delivered PT compared to the state-of-the-art intensity modulated x-ray RT (XT) at the home institution was evaluated. PROCEDURE: Twenty-four consecutive children referred for PT during 2010-2013 for craniospinal (CSI, n = 10), localized intracranial (IC, n = 7), head/neck (HN, n = 4) or parameningeal (PM, n = 3) lesions were included. The median age was 8 years (2-16 years). XT plans were generated for each patient, blinded to the PT delivered. Dosimetry, estimated growth hormone deficiency (GHD), and neurocognitive dysfunction (NCD) risks were compared for PT and XT (Wilcoxon). RESULTS: PT started (median) 5 weeks (± 1.3 weeks, 95% CI) after referral. For CSI patients, PT was clearly superior to XT plans with median dose reductions for the heart, lungs and thyroid of 17, 2.5 and 18 Gy, respectively (P = 0.005). The median estimated NCD and GHD risks were 1-3 (max 16) and 2 (max 61) percentage points, respectively, lower for PT compared to XT. The median of the mean doses to the brain, cochleae and pituitary gland was lower with PT than XT for the IC, H/N and PM patients (P < 0.039). For a single IC patient, the dose to hippocampi and optic chiasm was higher for PT compared to XT. CONCLUSIONS: PT clearly benefitted the patients studied, except for IC disease where differences between PT and XT were modest, and comparative PT and XT treatment planning is warranted prior to referral.


Asunto(s)
Neoplasias del Sistema Nervioso Central/radioterapia , Terapia de Protones/métodos , Adolescente , Niño , Preescolar , Irradiación Craneana/métodos , Femenino , Humanos , Masculino , Órganos en Riesgo , Planificación de la Radioterapia Asistida por Computador , Radioterapia de Intensidad Modulada , Derivación y Consulta , Estudios Retrospectivos , Médula Espinal/efectos de la radiación
8.
Pediatr Radiol ; 45(4): 570-81, 2015 Apr.
Artículo en Inglés | MEDLINE | ID: mdl-25378209

RESUMEN

BACKGROUND: PET/CT may be more helpful than CT alone for radiation therapy planning, but the added risk due to higher doses of ionizing radiation is unknown. OBJECTIVE: To estimate the risk of cancer induction and mortality attributable to the [F-18]2-fluoro-2-deoxyglucose (FDG) PET and CT scans used for radiation therapy planning in children with cancer, and compare to the risks attributable to the cancer treatment. MATERIALS AND METHODS: Organ doses and effective doses were estimated for 40 children (2-18 years old) who had been scanned using PET/CT as part of radiation therapy planning. The risk of inducing secondary cancer was estimated using the models in BEIR VII. The prognosis of an induced cancer was taken into account and the reduction in life expectancy, in terms of life years lost, was estimated for the diagnostics and compared to the life years lost attributable to the therapy. Multivariate linear regression was performed to find predictors for a high contribution to life years lost from the radiation therapy planning diagnostics. RESULTS: The mean contribution from PET to the effective dose from one PET/CT scan was 24% (range: 7-64%). The average proportion of life years lost attributable to the nuclear medicine dose component from one PET/CT scan was 15% (range: 3-41%). The ratio of life years lost from the radiation therapy planning PET/CT scans and that of the cancer treatment was on average 0.02 (range: 0.01-0.09). Female gender was associated with increased life years lost from the scans (P < 0.001). CONCLUSION: Using FDG-PET/CT instead of CT only when defining the target volumes for radiation therapy of children with cancer does not notably increase the number of life years lost attributable to diagnostic examinations.


Asunto(s)
Neoplasias de la Mama/mortalidad , Neoplasias de la Mama/radioterapia , Tomografía de Emisión de Positrones/estadística & datos numéricos , Dosis de Radiación , Protección Radiológica/métodos , Tomografía Computarizada por Rayos X/estadística & datos numéricos , Adolescente , Niño , Preescolar , Dinamarca/epidemiología , Femenino , Humanos , Esperanza de Vida , Masculino , Imagen Multimodal/estadística & datos numéricos , Prevalencia , Pronóstico , Años de Vida Ajustados por Calidad de Vida , Planificación de la Radioterapia Asistida por Computador/estadística & datos numéricos , Reproducibilidad de los Resultados , Medición de Riesgo/métodos , Sensibilidad y Especificidad , Tasa de Supervivencia , Adulto Joven
9.
J Neurooncol ; 118(1): 101-8, 2014 May.
Artículo en Inglés | MEDLINE | ID: mdl-24532196

RESUMEN

To determine visual outcome including the occurrence of radiation induced optic neuropathy (RION) as well as tumor control after fractionated stereotactic radiation therapy (FSRT) of benign anterior skull base meningiomas or pituitary adenomas. Thirty-nine patients treated with FSRT for anterior skull base meningiomas and 55 patients treated with FSRT for pituitary adenomas between January 1999 and December 2009 with at least 2 years follow-up were included. Patients were followed up prospectively with magnetic resonance imaging scans, visual acuity and visual field examinations. RION was found in four (10%) patients with anterior skull base meningiomas and seven patients (13%) with pituitary adenomas. The five-year actuarial freedom from 25% RION visual field loss was 94% following FSRT. Actuarial 2-, 5- and 10-year tumor control rates were 100, 88.4 and 64.5% for anterior skull base meningiomas and 100, 98.2 and 94.9% for pituitary adenomas, respectively. Patients with an impaired visual field function pre-FSRT were more likely to experience worsened function (p = 0.016). We found that RION, was a relatively uncommon event, in a large prospective cohort of patients that were systematically monitored following FSRT of benign anterior skull base tumors. Long term tumor control was favorable, especially for pituitary adenomas.


Asunto(s)
Enfermedades del Nervio Óptico/etiología , Complicaciones Posoperatorias/fisiopatología , Radiocirugia/efectos adversos , Neoplasias de la Base del Cráneo/cirugía , Adulto , Factores de Edad , Anciano , Femenino , Humanos , Estimación de Kaplan-Meier , Estudios Longitudinales , Imagen por Resonancia Magnética , Masculino , Persona de Mediana Edad , Estudios Retrospectivos , Agudeza Visual/fisiología , Campos Visuales/fisiología , Vías Visuales/patología
10.
Acta Oncol ; 53(8): 1005-11, 2014 Aug.
Artículo en Inglés | MEDLINE | ID: mdl-24937551

RESUMEN

BACKGROUND: Flattening filter-free (FFF) beams are an emerging technology that has not yet been widely implemented as standard practice in radiotherapy centers. To facilitate the clinical implementation of FFF, we attempted to elucidate the difference in plan quality and treatment delivery time compared to flattening filter beams (i.e. standard, STD) for several patient groups. We hypothesize that the treatment plan quality is comparable while the treatment delivery time of volumetric modulated arc therapy (VMAT) is considerably shorter using FFF beams, especially for stereotactic treatments. METHODS: A total of 120 patients treated for head and neck (H&N) tumors, high-grade glioma, prostate cancer, early stage lung cancer and intra-cranial metastatic disease (both single and multiple metastases) were included in the study. For each cohort, 20 consecutive patients were selected. The plans were generated using STD- and FFF-VMAT for both 6 MV and 10 MV, and were compared with respect to plan quality, monitor units and delivery time using Wilcoxon signed rank tests. RESULTS: For H&N and high-grade gliomas, there was a significant difference in homogeneity index in favor for STD-VMAT (p < 0.001). For the stereotactic sites there were no differences in plan conformity. Stereotactic FFF-VMAT plans required significantly shorter delivery time compared to STD-VMAT plans (p < 0.001) for higher dose per fraction, on average 54.5% for 6 MV and 71.4% for 10 MV. FFF-VMAT generally required a higher number of MU/Gy (p < 0.001), on average 7.0% for 6 MV and 8.4% for 10 MV. CONCLUSION: It was generally possible to produce FFF-VMAT plans with the same target dose coverage and doses to organs at risk as STD-VMAT plans. Target dose homogeneity tended to be somewhat inferior for FFF-VMAT for the larger targets investigated. For stereotactic radiotherapy, FFF-VMAT resulted in a considerable time gain while maintaining similar plan quality compared to STD beams.


Asunto(s)
Neoplasias Encefálicas/radioterapia , Glioma/radioterapia , Neoplasias de Cabeza y Cuello/radioterapia , Neoplasias Pulmonares/radioterapia , Neoplasias de la Próstata/radioterapia , Planificación de la Radioterapia Asistida por Computador/métodos , Radioterapia de Intensidad Modulada/métodos , Adulto , Anciano , Anciano de 80 o más Años , Neoplasias Encefálicas/secundario , Femenino , Filtración/instrumentación , Humanos , Masculino , Persona de Mediana Edad , Órganos en Riesgo , Neoplasias Orofaríngeas/radioterapia , Radioterapia de Intensidad Modulada/instrumentación , Estadísticas no Paramétricas , Factores de Tiempo
11.
Acta Oncol ; 53(4): 462-70, 2014 Apr.
Artículo en Inglés | MEDLINE | ID: mdl-24274390

RESUMEN

BACKGROUND: A mathematical framework is presented for simultaneously quantifying and evaluating the trade-off between tumor control and late complications for risk-based radiation therapy (RT) decision-support. To demonstrate this, we estimate life years lost (LYL) attributable to tumor recurrence, late cardiac toxicity and secondary cancers for standard-risk pediatric medulloblastoma (MB) patients and compare the effect of dose re-distribution on a common scale. METHODS: Total LYL were derived, based on the LYL attributable to radiation-induced late complications and the LYL from not controlling the primary disease. We compared the estimated LYL for three different treatments in 10 patients: 1) standard 3D conformal RT; 2) proton therapy; 3) risk-adaptive photon treatment lowering the dose to part of the craniospinal (CS) target volume situated close to critical risk organs. RESULTS: Late toxicity is important, with 0.75 LYL (95% CI 0.60-7.2 years) for standard uniform 24 Gy CS irradiation. However, recurrence risk dominates the total LYL with 14.2 years (95% CI 13.4-16.6 years). Compared to standard treatment, a risk-adapted strategy prescribing 12 Gy to the spinal volume encompassing the 1st-10th thoracic vertebrae (Th1-Th10), and 36 Gy to the remaining CS volume, estimated a LYL reduction of 0.90 years (95% CI -0.18-2.41 years). Proton therapy with 36 Gy to the whole CS volume was associated with significantly fewer LYL compared to the risk-adapted photon strategies, with a mean LYL difference of 0.50 years (95% CI 0.25-2.60 years). CONCLUSIONS: Optimization of RT prescription strategies considering both late complications and the risk of recurrence, an all-cause mortality dose painting approach, was demonstrated. The risk-adapted techniques compared favorably to the standard, and although in this context, the gain is small compared to estimated uncertainty, this study demonstrates a framework for all-cause mortality risk estimation, rather than evaluates direct clinical applicability of risk-adapted strategies.


Asunto(s)
Neoplasias Cerebelosas/radioterapia , Irradiación Craneoespinal/efectos adversos , Meduloblastoma/radioterapia , Modelos Teóricos , Recurrencia Local de Neoplasia/diagnóstico , Traumatismos por Radiación/etiología , Adolescente , Adulto , Factores de Edad , Anciano , Anciano de 80 o más Años , Neoplasias Cerebelosas/mortalidad , Neoplasias Cerebelosas/prevención & control , Niño , Preescolar , Femenino , Estudios de Seguimiento , Humanos , Masculino , Meduloblastoma/mortalidad , Meduloblastoma/prevención & control , Persona de Mediana Edad , Recurrencia Local de Neoplasia/mortalidad , Fotones/efectos adversos , Pronóstico , Terapia de Protones/efectos adversos , Dosificación Radioterapéutica , Planificación de la Radioterapia Asistida por Computador/efectos adversos , Radioterapia Conformacional/efectos adversos , Radioterapia de Intensidad Modulada/efectos adversos , Factores de Riesgo , Tasa de Supervivencia , Adulto Joven
12.
Child Neuropsychol ; 30(1): 22-44, 2024 02.
Artículo en Inglés | MEDLINE | ID: mdl-36744788

RESUMEN

Survivors of Pediatric Brain Tumors (PBTs) treated with cranial radiation therapy (CRT) often experience a decline in neurocognitive test scores. Less is known about the neurocognitive development of non-irradiated survivors of PBTs. The aim of this study was to statistically model neurocognitive development after PBT in both irradiated and non-irradiated survivors and to find clinical variables associated with the rate of decline in neurocognitive scores. A total of 151 survivors were included in the study. Inclusion criteria: Diagnosis of PBT between 2001 and 2013 or earlier diagnosis of PBT and turning 18 years of age between 2006 and 2013. Exclusion criteria: Death within a year from diagnosis, neurocutaneous syndromes, severe intellectual disability. Clinical neurocognitive data were collected retrospectively from medical records. Multilevel linear modeling was used to evaluate the rate of decline in neurocognitive measures and factors associated with the same. A decline was found in most measures for both irradiated and non-irradiated survivors. Ventriculo-peritoneal (VP) shunting and treatment with whole-brain radiation therapy (WBRT) were associated with a faster decline in neurocognitive scores. Male sex and supratentorial lateral tumor were associated with lower scores. Verbal learning measures were either stable or improving. Survivors of PBTs show a pattern of decline in neurocognitive scores irrespective of treatment received, which suggests the need for routine screening for neurocognitive rehabilitation. However, survivors treated with WBRT and/or a VP shunt declined at a faster rate and appear to be at the highest risk of negative neurocognitive outcomes and to have the greatest need for neurocognitive rehabilitation.


Asunto(s)
Neoplasias Encefálicas , Niño , Humanos , Masculino , Neoplasias Encefálicas/psicología , Estudios Retrospectivos , Irradiación Craneana , Sobrevivientes
13.
Front Oncol ; 14: 1425240, 2024.
Artículo en Inglés | MEDLINE | ID: mdl-39077466

RESUMEN

Introduction: FLASH radiotherapy (RT) has emerged as a promising modality, demonstrating both a normal tissue sparing effect and anticancer efficacy. We have previously reported on the safety and efficacy of single fraction FLASH RT in the treatment of oral tumors in canine cancer patients, showing tumor response but also a risk of radiation-induced severe late adverse effects (osteoradionecrosis) for doses ≥35 Gy. Accordingly, the objective in this study was to investigate if single fraction high dose FLASH RT is safe for treating non-oral tumors. Methods: Privately-owned dogs with superficial tumors or microscopic residual disease were included. Treatment was generally delivered as a single fraction of 15-35 Gy 10 MeV electron FLASH RT, although two dogs were re-irradiated at a later timepoint. Follow-up visits were conducted up to 12 months post-treatment to evaluate treatment efficiency and adverse effects. Results: Fourteen dogs with 16 tumors were included, of which nine tumors were treated for gross disease whilst seven tumors were treated post-surgery for microscopic residual disease. Four treatment sites treated with 35 Gy had ulceration post irradiation, which was graded as severe adverse effect. Only mild adverse effects were observed for the remaining treatment sites. None of the patients with microscopic disease experienced recurrence (0/7), and all patients with macroscopic disease showed either a complete (5/9) or a partial response (4/9). Five dogs were euthanized due to clinical disease progression. Discussion: Our study demonstrates that single fraction high dose FLASH RT is generally safe, with few severe adverse effects, particularly in areas less susceptible to radiation-induced damage. In addition, our study indicates that FLASH has anti-tumor efficacy in a clinical setting. No osteoradionecrosis was observed in this study, although other types of high-grade adverse effects including ulcer-formations were observed for the highest delivered dose (35 Gy). Overall, we conclude that osteoradionecrosis following single fraction, high dose FLASH does not appear to be a general problem for non-oral tumor locations. Also, as has been shown previously for oral tumors, 30 Gy appeared to be the maximum safe dose to deliver with single fraction FLASH RT.

14.
Phys Imaging Radiat Oncol ; 29: 100555, 2024 Jan.
Artículo en Inglés | MEDLINE | ID: mdl-38405431

RESUMEN

Background and Purpose: Hippocampal-sparing (HS) is a method that can potentially reduce late cognitive complications for pediatric medulloblastoma (MB) patients treated with craniospinal proton therapy (PT). The aim of this study was to investigate robustness and dosimetric plan verification of pencil beam scanning HS PT. Materials and Methods: HS and non-HS PT plans for the whole brain part of craniospinal treatment were created for 15 pediatric MB patients. A robust evaluation of the plans was performed. Plans were recalculated in a water phantom and measured field-by-field using an ion chamber detector at depths corresponding to the central part of hippocampi. All HS and non-HS fields were measured with the standard resolution of the detector and in addition 16 HS fields were measured with high resolution. Measured and planned dose distributions were compared using gamma evaluation. Results: The median mean hippocampus dose was reduced from 22.9 Gy (RBE) to 8.9 Gy (RBE), while keeping CTV V95% above 95 % for all nominal HS plans. HS plans were relatively robust regarding hippocampus mean dose, however, less robust regarding target coverage and maximum dose compared to non-HS plans. For standard resolution measurements, median pass rates were 99.7 % for HS and 99.5 % for non-HS plans (p < 0.001). For high-resolution measurements, median pass rates were 100 % in the hippocampus region and 98.2 % in the surrounding region. Conclusions: A substantial reduction of dose in the hippocampus region appeared feasible. Dosimetric accuracy of HS plans was comparable to non-HS plans and agreed well with planned dose distribution in the hippocampus region.

15.
J Appl Clin Med Phys ; 14(5): 187-95, 2013 Sep 06.
Artículo en Inglés | MEDLINE | ID: mdl-24036871

RESUMEN

The purpose of this study was to evaluate the stability of complex markers implanted into lung tumors throughout a course of stereotactic body radiotherapy (SBRT). Fifteen patients referred for lung SBRT were prospectively included. Radio-opaque markers were implanted percutaneously, guided by computed tomography (CT). Deep inspiration breath-hold CT scans (BHCT) were acquired at planning and on three treatment days. The treatment days' BHCTs were registered to the planning BHCT. Intraobserver uncertainty in both tumor and marker registration was determined. Deviations in the difference between tumor and marker-based image registrations of the BHCT scans during treatment quantified the marker stability. Marker position deviation relative to tumor position of less than 2 mm in all three dimensions was considered acceptable for treatment delivery precision. Intra observer uncertainties for image registration in the left-right (LR), anterior-posterior (AP), craniocaudal (CC) directions and three-dimensional vector (3D) were 0.9 mm, 0.9 mm, 1.0 mm, and 1.1 mm (SD) for tumor registration and 0.3 mm, 0.5 mm, 0.7 mm, and 0.7 mm (SD) for marker registration. Mean 3D differences for tumor registrations on all days were significantly larger than for 3D marker registrations (p = 0.007). Overall median differences between tumor and marker position were 0.0 mm (range -2.9 to 2.6 mm) in LR, 0.0 mm (-1.8 to 1.5 mm) in AP, and -0.2 mm (-2.6 to 2.8 mm) in CC directions. Four patients had deviations exceeding 2 mm in one or more registrations throughout the SBRT course. This is the first study to evaluate stability of complex markers implanted percutaneously into lung tumors for image guidance in SBRT. We conclude that the observed stability of marker position within the tumor indicates that complex markers can be used as surrogates for tumor position during a short course of SBRT as long as the uncertainties related to their position within the tumor are incorporated into the planning target volume.


Asunto(s)
Marcadores Fiduciales , Neoplasias Pulmonares/diagnóstico por imagen , Neoplasias Pulmonares/cirugía , Radiocirugia , Planificación de la Radioterapia Asistida por Computador , Tomografía Computarizada por Rayos X , Algoritmos , Humanos , Movimiento , Respiración
16.
Front Oncol ; 13: 1256760, 2023.
Artículo en Inglés | MEDLINE | ID: mdl-37766866

RESUMEN

Background: FLASH radiotherapy (RT) is a novel method for delivering ionizing radiation, which has been shown in preclinical studies to have a normal tissue sparing effect and to maintain anticancer efficacy as compared to conventional RT. Treatment of head and neck tumors with conventional RT is commonly associated with severe toxicity, hence the normal tissue sparing effect of FLASH RT potentially makes it especially advantageous for treating oral tumors. In this work, the objective was to study the adverse effects of dogs with spontaneous oral tumors treated with FLASH RT. Methods: Privately-owned dogs with macroscopic malignant tumors of the oral cavity were treated with a single fraction of ≥30Gy electron FLASH RT and subsequently followed for 12 months. A modified conventional linear accelerator was used to deliver the FLASH RT. Results: Eleven dogs were enrolled in this prospective study. High grade adverse effects were common, especially if bone was included in the treatment field. Four out of six dogs, who had bone in their treatment field and lived at least 5 months after RT, developed osteoradionecrosis at 3-12 months post treatment. The treatment was overall effective with 8/11 complete clinical responses and 3/11 partial responses. Conclusion: This study shows that single-fraction high dose FLASH RT was generally effective in this mixed group of malignant oral tumors, but the risk of osteoradionecrosis is a serious clinical concern. It is possible that the risk of osteonecrosis can be mitigated through fractionation and improved dose conformity, which needs to be addressed before moving forward with clinical trials in human cancer patients.

17.
Radiother Oncol ; 184: 109663, 2023 07.
Artículo en Inglés | MEDLINE | ID: mdl-37059335

RESUMEN

BACKGROUND AND PURPOSE: Target delineation in glioblastoma is still a matter of extensive research and debate. This guideline aims to update the existing joint European consensus on delineation of the clinical target volume (CTV) in adult glioblastoma patients. MATERIAL AND METHODS: The ESTRO Guidelines Committee identified 14 European experts in close interaction with the ESTRO clinical committee and EANO who discussed and analysed the body of evidence concerning contemporary glioblastoma target delineation, then took part in a two-step modified Delphi process to address open questions. RESULTS: Several key issues were identified and are discussed including i) pre-treatment steps and immobilisation, ii) target delineation and the use of standard and novel imaging techniques, and iii) technical aspects of treatment including planning techniques and fractionation. Based on the EORTC recommendation focusing on the resection cavity and residual enhancing regions on T1-sequences with the addition of a reduced 15 mm margin, special situations are presented with corresponding potential adaptations depending on the specific clinical situation. CONCLUSIONS: The EORTC consensus recommends a single clinical target volume definition based on postoperative contrast-enhanced T1 abnormalities, using isotropic margins without the need to cone down. A PTV margin based on the individual mask system and IGRT procedures available is advised; this should usually be no greater than 3 mm when using IGRT.


Asunto(s)
Glioblastoma , Adulto , Humanos , Glioblastoma/diagnóstico por imagen , Glioblastoma/radioterapia , Glioblastoma/tratamiento farmacológico , Planificación de la Radioterapia Asistida por Computador/métodos , Fraccionamiento de la Dosis de Radiación
18.
Cancer ; 118(21): 5432-40, 2012 Nov 01.
Artículo en Inglés | MEDLINE | ID: mdl-22517408

RESUMEN

BACKGROUND: The authors developed a framework for estimating and comparing the risks of various long-term complications on a common scale and applied it to 3 different techniques for craniospinal irradiation in patients with pediatric medulloblastoma. METHODS: Radiation dose-response parameters related to excess hazard ratios for secondary breast, lung, stomach, and thyroid cancer; heart failure, and myocardial infarction were derived from large published clinical series. Combined with age-specific and sex-specific hazards in the US general population, the dose-response analysis yielded excess hazards of complications for a cancer survivor as a function of attained age. After adjusting for competing risks of death, life years lost (LYL) were estimated based on excess hazard and prognosis of a complication for 3-dimensional conformal radiotherapy (3D CRT), volumetric modulated arc therapy (VMAT), and intensity-modulated proton therapy (IMPT). RESULTS: Lung cancer contributed most to the estimated LYL, followed by myocardial infarction, and stomach cancer. The estimates of breast or thyroid cancer incidence were higher than those for lung and stomach cancer incidence, but LYL were lower because of the relatively good prognosis. Estimated LYL ranged between 1.90 years for 3D CRT to 0.28 years for IMPT. In a paired comparison, IMPT was associated with significantly fewer LYL than both photon techniques. CONCLUSIONS: Estimating the risk of late complications is associated with considerable uncertainty, but including prognosis and attained age at an event to obtain the more informative LYL estimate added relatively little to this uncertainty.


Asunto(s)
Neoplasias Cerebelosas/radioterapia , Irradiación Craneoespinal/efectos adversos , Meduloblastoma/radioterapia , Adolescente , Factores de Edad , Neoplasias Cerebelosas/complicaciones , Niño , Preescolar , Irradiación Craneoespinal/métodos , Relación Dosis-Respuesta en la Radiación , Femenino , Humanos , Masculino , Meduloblastoma/complicaciones , Terapia de Protones , Radioterapia Conformacional/efectos adversos , Radioterapia de Intensidad Modulada/efectos adversos , Riesgo
19.
Med Phys ; 39(3): 1588-94, 2012 Mar.
Artículo en Inglés | MEDLINE | ID: mdl-22380391

RESUMEN

PURPOSE: Real-time dynamic multileaf collimator (MLC) tracking for management of intrafraction tumor motion can be challenging for highly modulated beams, as the leaves need to travel far to adjust for target motion perpendicular to the leaf travel direction. The plan modulation can be reduced by using a leaf position constraint (LPC) that reduces the difference in the position of adjacent MLC leaves in the plan. The purpose of this study was to investigate the impact of the LPC on the quality of inversely optimized arc radiotherapy plans and the effect of the MLC motion pattern on the dosimetric accuracy of MLC tracking delivery. Specifically, the possibility of predicting the accuracy of MLC tracking delivery based on the plan modulation was investigated. METHODS: Inversely optimized arc radiotherapy plans were created on CT-data of three lung cancer patients. For each case, five plans with a single 358° arc were generated with LPC priorities of 0 (no LPC), 0.25, 0.5, 0.75, and 1 (highest possible LPC), respectively. All the plans had a prescribed dose of 2 Gy × 30, used 6 MV, a maximum dose rate of 600 MU/min and a collimator angle of 45° or 315°. To quantify the plan modulation, an average adjacent leaf distance (ALD) was calculated by averaging the mean adjacent leaf distance for each control point. The linear relationship between the plan quality [i.e., the calculated dose distributions and the number of monitor units (MU)] and the LPC was investigated, and the linear regression coefficient as well as a two tailed confidence level of 95% was used in the evaluation. The effect of the plan modulation on the performance of MLC tracking was tested by delivering the plans to a cylindrical diode array phantom moving with sinusoidal motion in the superior-inferior direction with a peak-to-peak displacement of 2 cm and a cycle time of 6 s. The delivery was adjusted to the target motion using MLC tracking, guided in real-time by an infrared optical system. The dosimetric results were evaluated using gamma index evaluation with static target measurements as reference. RESULTS: The plan quality parameters did not depend significantly on the LPC (p ≥ 0.066), whereas the ALD depended significantly on the LPC (p < 0.001). The gamma index failure rate depended significantly on the ALD, weighted to the percentage of the beam delivered in each control point of the plan (ALD(w)) when MLC tracking was used (p < 0.001), but not for delivery without MLC tracking (p ≥ 0.342). The gamma index failure rate with the criteria of 2% and 2 mm was decreased from > 33.9% without MLC tracking to <31.4% (LPC 0) and <2.2% (LPC 1) with MLC tracking. CONCLUSIONS: The results indicate that the dosimetric robustness of MLC tracking delivery of an inversely optimized arc radiotherapy plan can be improved by incorporating leaf position constraints in the objective function without otherwise affecting the plan quality. The dosimetric robustness may be estimated prior to delivery by evaluating the ALD(w) of the plan.


Asunto(s)
Radioterapia Asistida por Computador/métodos , Movimiento , Fantasmas de Imagen , Radiometría , Factores de Tiempo
20.
Radiat Oncol ; 17(1): 114, 2022 Jun 28.
Artículo en Inglés | MEDLINE | ID: mdl-35765038

RESUMEN

BACKGROUND: Delineation of organs at risk (OAR) for anal cancer radiation therapy treatment planning is a manual and time-consuming process. Deep learning-based methods can accelerate and partially automate this task. The aim of this study was to develop and evaluate a deep learning model for automated and improved segmentations of OAR in the pelvic region. METHODS: A 3D, deeply supervised U-Net architecture with shuffle attention, referred to as Pelvic U-Net, was trained on 143 computed tomography (CT) volumes, to segment OAR in the pelvic region, such as total bone marrow, rectum, bladder, and bowel structures. Model predictions were evaluated on an independent test dataset (n = 15) using the Dice similarity coefficient (DSC), the 95th percentile of the Hausdorff distance (HD95), and the mean surface distance (MSD). In addition, three experienced radiation oncologists rated model predictions on a scale between 1-4 (excellent, good, acceptable, not acceptable). Model performance was also evaluated with respect to segmentation time, by comparing complete manual delineation time against model prediction time without and with manual correction of the predictions. Furthermore, dosimetric implications to treatment plans were evaluated using different dose-volume histogram (DVH) indices. RESULTS: Without any manual corrections, mean DSC values of 97%, 87% and 94% were found for total bone marrow, rectum, and bladder. Mean DSC values for bowel cavity, all bowel, small bowel, and large bowel were 95%, 91%, 87% and 81%, respectively. Total bone marrow, bladder, and bowel cavity segmentations derived from our model were rated excellent (89%, 93%, 42%), good (9%, 5%, 42%), or acceptable (2%, 2%, 16%) on average. For almost all the evaluated DVH indices, no significant difference between model predictions and manual delineations was found. Delineation time per patient could be reduced from 40 to 12 min, including manual corrections of model predictions, and to 4 min without corrections. CONCLUSIONS: Our Pelvic U-Net led to credible and clinically applicable OAR segmentations and showed improved performance compared to previous studies. Even though manual adjustments were needed for some predicted structures, segmentation time could be reduced by 70% on average. This allows for an accelerated radiation therapy treatment planning workflow for anal cancer patients.


Asunto(s)
Neoplasias del Ano , Órganos en Riesgo , Neoplasias del Ano/radioterapia , Atención , Humanos , Redes Neurales de la Computación , Pelvis , Semántica
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA