1.
Rev Esp Enferm Dig ; 2023 Nov 06.
Artículo en Inglés | MEDLINE | ID: mdl-37929958

RESUMEN

BACKGROUND AND AIMS: The fully-covered self-expanding metal stent (SEMS) has a role in the management of refractory acute variceal haemorrhage. The aim of this study was to evaluate its effectiveness and complications in real-world practice. PATIENTS AND METHODS: An observational, descriptive, multicenter study was carried out. Eight patients with clinically significant portal hypertension who underwent a SEMS were included. RESULTS: SEMS placement controlled acute bleeding in 7 patients with technical success. Stents were removed after a median of 8 days. Rescue transjugular intrahepatic portosystemic shunt was performed around 48 hours after SEMS placement. Four patients survived after successful SEMS removal. The most common adverse event was stent loop in 2 patients. CONCLUSIONS: In our experience, SEMS was highly effective in controlling acute refractory variceal bleeding. Bleeding-related mortality rate was probably due to impossibility of TIPS implantation. Stent loop was a common limiting factor.