Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 19 de 19
Filtrar
1.
Phys Rev Lett ; 131(22): 222501, 2023 Dec 01.
Artículo en Inglés | MEDLINE | ID: mdl-38101385

RESUMEN

We report on the results obtained with the global CUPID-0 background model, which combines the data collected in the two measurement campaigns for a total exposure of 8.82 kg×yr of ^{82}Se. We identify with improved precision the background sources within the 3 MeV energy region, where neutrinoless double ß decay of ^{82}Se and ^{100}Mo is expected, making more solid the foundations for the background budget of the next-generation CUPID experiment. Relying on the excellent data reconstruction, we measure the two-neutrino double ß-decay half-life of ^{82}Se with unprecedented accuracy: T_{1/2}^{2ν}=[8.69±0.05(stat)_{-0.06}^{+0.09}(syst)]×10^{19} yr.

2.
Ter Arkh ; 95(11): 970-975, 2023 Dec 22.
Artículo en Ruso | MEDLINE | ID: mdl-38158954

RESUMEN

The differential diagnosis of neoplasms of various localizations is the primary task in clinical practice of all physicians. We present a description of the case of invasion with Dirofilaria repens in the lung of a 68-year-old patient. In 2016 the patient was diagnosed with cancer of the left kidney and underwent a left-sided nephrectomy. During the dynamic observation in 2019, a lump was found in the left lung, which was regarded as a metastasis. An atypical SIX resection of the left lung was performed. Microscopy of the removed lump revealed the presence of a nematode of the genus Dirofilaria, presumably D. repens. The species identity of D. repens was confirmed by polymerase chain reaction using species-specific primers. It is known that the morphological identification of parasites up to the species in the surgical material presents certain difficulties and requires high professional training of the researcher. Therefore, the diagnosis of dirofilariasis in atypical localizations of nematodes in the human body is of great importance in the differentiation of malignant and benign formations, and the use of the polymerase chain reaction method can significantly increase the accuracy in establishing the final diagnosis.


Asunto(s)
Dirofilaria repens , Dirofilariasis , Animales , Humanos , Anciano , Dirofilariasis/diagnóstico , Dirofilariasis/cirugía , Dirofilaria repens/genética , Reacción en Cadena de la Polimerasa , Pulmón/patología , Diagnóstico Diferencial
3.
Phys Rev Lett ; 129(11): 111801, 2022 Sep 09.
Artículo en Inglés | MEDLINE | ID: mdl-36154394

RESUMEN

CUPID-0, an array of Zn^{82}Se cryogenic calorimeters, was the first medium-scale demonstrator of the scintillating bolometers' technology. The first project phase (March 2017-December 2018) allowed the most stringent limit on the neutrinoless double beta decay half-life of the isotope of interest, ^{82}Se, to be set. After a six month long detector upgrade, CUPID-0 began its second and last phase (June 2019-February 2020). In this Letter, we describe the search for neutrinoless double beta decay of ^{82}Se with a total exposure (phase I+II) of 8.82 kg yr^{-1} of isotope. We set a limit on the half-life of ^{82}Se to the ground state of ^{82}Kr of T_{1/2}^{0ν}(^{82}Se)>4.6×10^{24} yr (90% credible interval), corresponding to an effective Majorana neutrino mass m_{ßß}<(263-545) meV. We also set the most stringent lower limits on the neutrinoless decays of ^{82}Se to the 0_{1}^{+}, 2_{1}^{+}, and 2_{2}^{+} excited states of ^{82}Kr, finding 1.8×10^{23} yr, 3.0×10^{23} yr, and 3.2×10^{23} yr (90% credible interval) respectively.

4.
Ter Arkh ; 92(11): 62-64, 2020 Dec 26.
Artículo en Ruso | MEDLINE | ID: mdl-33720606

RESUMEN

The paper presents the case of the right-sided inguinal inflammation of a lymph node as a result of invasion of Dirofilaria repens, the parasitic pathogen of subcutaneous dirofilariasis in animals of the canine family. The diagnosis was verified on the basis of the parallel application of morphological studies of cross sections of the nematode in histological samples and the molecular biological method polymerase chain reaction of scrapings of histological material. The localization of this helminth inside the cavities of the human body is extremely rare. Only isolated cases of atypical localization of D. repens are described: in the organs of the chest, cervical lymphatic node in the spermatic cord and epididymis, which led to pseudotumor formations that needed to be differentiated with neoplastic processes. This case is of great interest to experts of various fields (surgeons, oncologists, infectious disease specialists and pathologists), primarily in the differential diagnosis of malignant neoplasms of the lymphatic system.


Asunto(s)
Dirofilaria repens , Dirofilariasis , Linfadenitis , Diagnóstico Diferencial , Dirofilaria repens/genética , Dirofilariasis/diagnóstico , Humanos , Linfadenitis/diagnóstico , Masculino , Reacción en Cadena de la Polimerasa
5.
Phys Rev Lett ; 123(3): 032501, 2019 Jul 19.
Artículo en Inglés | MEDLINE | ID: mdl-31386478

RESUMEN

CUPID-0 is the first pilot experiment of CUPID, a next-generation project for the measurement of neutrinoless double beta decay (0νDBD) with scintillating bolometers. The detector, consisting of 24 enriched and 2 natural ZnSe crystals, has been taking data at Laboratori Nazionali del Gran Sasso from June 2017 to December 2018, collecting a ^{82}Se exposure of 5.29 kg×yr. In this Letter we present the phase-I results in the search for 0νDBD. We demonstrate that the technology implemented by CUPID-0 allows us to reach the lowest background for calorimetric experiments: (3.5_{-0.9}^{+1.0})×10^{-3} counts/(keV kg yr). Monitoring 3.88×10^{25} ^{82}Se nuclei×yr we reach a 90% credible interval median sensitivity of T_{1/2}^{0ν}>5.0×10^{24} yr and set the most stringent limit on the half-life of ^{82}Se 0νDBD: T_{1/2}^{0ν}>3.5×10^{24} yr (90% credible interval), corresponding to m_{ßß}<(311-638) meV depending on the nuclear matrix element calculations.

6.
Phys Rev Lett ; 123(26): 262501, 2019 Dec 31.
Artículo en Inglés | MEDLINE | ID: mdl-31951429

RESUMEN

We report on the measurement of the two-neutrino double-ß decay of ^{82}Se performed for the first time with cryogenic calorimeters, in the framework of the CUPID-0 experiment. With an exposure of 9.95 kg yr of Zn^{82}Se, we determine the two-neutrino double-ß decay half-life of ^{82}Se with an unprecedented precision level, T_{1/2}^{2ν}=[8.60±0.03(stat) _{-0.13}^{+0.19}(syst)]×10^{19} yr. The very high signal-to-background ratio, along with the detailed reconstruction of the background sources allowed us to identify the single state dominance as the underlying mechanism of such a process, demonstrating that the higher state dominance hypothesis is disfavored at the level of 5.5σ.

7.
Phys Rev Lett ; 120(23): 232502, 2018 Jun 08.
Artículo en Inglés | MEDLINE | ID: mdl-29932707

RESUMEN

We report the result of the search for neutrinoless double beta decay of ^{82}Se obtained with CUPID-0, the first large array of scintillating Zn^{82}Se cryogenic calorimeters implementing particle identification. We observe no signal in a 1.83 kg yr ^{82}Se exposure, and we set the most stringent lower limit on the 0νßß ^{82}Se half-life T_{1/2}^{0ν}>2.4×10^{24} yr (90% credible interval), which corresponds to an effective Majorana neutrino mass m_{ßß}<(376-770) meV depending on the nuclear matrix element calculations. The heat-light readout provides a powerful tool for the rejection of α particles and allows us to suppress the background in the region of interest down to (3.6_{-1.4}^{+1.9})×10^{-3} counts/(keV kg yr), an unprecedented level for this technique.

8.
Eur Phys J C Part Fields ; 83(5): 398, 2023.
Artículo en Inglés | MEDLINE | ID: mdl-37188220

RESUMEN

A 510 day long-term measurement of a 45.3 g platinum foil acting as the sample and high voltage contact in an ultra-low-background high purity germanium detector was performed at Laboratori Nazionali del Gran Sasso (Italy). The data was used for a detailed study of double beta decay modes in natural platinum isotopes. Limits are set in the range O(1014-1019) years (90% C.L.) for several double beta decay transitions to excited states confirming, and partially extending existing limits. The highest sensitivity of the measurement, greater than 1019 years, was achieved for the two neutrino and neutrinoless double beta decay modes of the isotope 198Pt. Additionally, novel limits for inelastic dark matter scattering on 195Pt are placed up to mass splittings of approximately 500 keV. We analyze several techniques to extend the sensitivity and propose a few approaches for future medium-scale experiments with platinum-group elements.

9.
Dalton Trans ; 51(17): 6944-6954, 2022 May 03.
Artículo en Inglés | MEDLINE | ID: mdl-35451447

RESUMEN

Crystals of metal hexachlorides Cs2MCl6 (M = Hf or Zr) have recently emerged as promising materials for scintillation applications due to their excellent energy resolution. In this work, we investigated the crystal structure and scintillation properties of Cs2HfCl6 and Cs2ZrCl6 crystals in the broad temperature range from 9 to 300 K. X-ray diffraction data confirmed the same cubic structure (space group Fm3m) for Cs2HfCl6 and Cs2ZrCl6 over the entire examined temperature range. The room temperature scintillation light yield of Cs2HfCl6 excited with a 137Cs γ-source is measured to be 24 800 photons per MeV, while Cs2ZrCl6 exhibits 33 900 photons per MeV resulting in energy resolutions of 5.3% and 4.5%, respectively. The alpha-to-beta ratio determined at room temperature for 5.5 MeV α-particles from an 241Am source is equal to 0.39 for Cs2HfCl6 and 0.35 for Cs2ZrCl6. The measurements of scintillation decay curves revealed complex kinetics due to delayed recombination processes. A tangible enhancement of the scintillation yield with heating is observed in the 125-150 K range. This effect is a manifestation of negative thermal quenching explained by thermal activation of trapped carriers. A model of the emission centre is proposed that consistently explains the observed changes of emission intensity with temperature in the crystals under study.

10.
Eur Phys J C Part Fields ; 81(8): 722, 2021.
Artículo en Inglés | MEDLINE | ID: mdl-34720725

RESUMEN

Localization and modeling of radioactive contaminations is a challenge that ultra-low background experiments are constantly facing. These are fundamental steps both to extract scientific results and to further reduce the background of the detectors. Here we present an innovative technique based on the analysis of α - α delayed coincidences in 232 Th and 238 U decay chains, developed to investigate the contaminations of the ZnSe crystals in the CUPID-0 experiment. This method allows to disentangle surface and bulk contaminations of the detectors relying on the different probability to tag delayed coincidences as function of the α decay position.

11.
Eur Phys J C Part Fields ; 78(11): 888, 2018.
Artículo en Inglés | MEDLINE | ID: mdl-30881205

RESUMEN

The CUPID-0 experiment searches for double beta decay using cryogenic calorimeters with double (heat and light) read-out. The detector, consisting of 24 ZnSe crystals 95 % enriched in 82 Se and two natural ZnSe crystals, started data-taking in 2017 at Laboratori Nazionali del Gran Sasso. We present the search for the neutrino-less double beta decay of 82 Se into the 0 1 + , 2 1 + and 2 2 + excited states of 82 Kr with an exposure of 5.74 kg · yr (2.24 × 10 25  emitters · yr). We found no evidence of the decays and set the most stringent limits on the widths of these processes: Γ ( 82 Se → 82 Kr 0 1 + )8.55 × 10 - 24  yr - 1 , Γ ( 82 Se → 82 Kr 2 1 + ) < 6.25 × 10 - 24  yr - 1 , Γ ( 82 Se → 82 Kr 2 2 + )8.25 × 10 - 24  yr - 1 (90 % credible interval).

12.
Eur Phys J C Part Fields ; 78(9): 734, 2018.
Artículo en Inglés | MEDLINE | ID: mdl-30839752

RESUMEN

The suppression of spurious events in the region of interest for neutrinoless double beta decay will play a major role in next generation experiments. The background of detectors based on the technology of cryogenic calorimeters is expected to be dominated by α particles, that could be disentangled from double beta decay signals by exploiting the difference in the emission of the scintillation light. CUPID-0, an array of enriched Zn 82 Se scintillating calorimeters, is the first large mass demonstrator of this technology. The detector started data-taking in 2017 at the Laboratori Nazionali del Gran Sasso with the aim of proving that dual read-out of light and heat allows for an efficient suppression of the α background. In this paper we describe the software tools we developed for the analysis of scintillating calorimeters and we demonstrate that this technology allows to reach an unprecedented background for cryogenic calorimeters.

13.
Eur Phys J C Part Fields ; 78(5): 428, 2018.
Artículo en Inglés | MEDLINE | ID: mdl-30996670

RESUMEN

The CUPID-0 detector hosted at the Laboratori Nazionali del Gran Sasso, Italy, is the first large array of enriched scintillating cryogenic detectors for the investigation of 82 Se neutrinoless double-beta decay ( 0 ν ß ß ). CUPID-0 aims at measuring a background index in the region of interest (RoI) for 0 ν ß ß at the level of 10 - 3  counts/(keV kg years), the lowest value ever measured using cryogenic detectors. CUPID-0 operates an array of Zn 82 Se scintillating bolometers coupled with bolometric light detectors, with a state of the art technology for background suppression and thorough protocols and procedures for the detector preparation and construction. In this paper, the different phases of the detector design and construction will be presented, from the material selection (for the absorber production) to the new and innovative detector structure. The successful construction of the detector lead to promising preliminary detector performance which is discussed here.

14.
Eur Phys J C Part Fields ; 76(7): 364, 2016.
Artículo en Inglés | MEDLINE | ID: mdl-28280442

RESUMEN

The R&D activity performed during the last years proved the potential of ZnSe scintillating bolometers to the search for neutrino-less double beta decay, motivating the realization of the first large-mass experiment based on this technology: CUPID-0. The isotopic enrichment in [Formula: see text]Se, the Zn[Formula: see text]Se crystals growth, as well as the light detectors production have been accomplished, and the experiment is now in construction at Laboratori Nazionali del Gran Sasso (Italy). In this paper we present the results obtained testing the first three Zn[Formula: see text]Se crystals operated as scintillating bolometers, and we prove that their performance in terms of energy resolution, background rejection capability and intrinsic radio-purity complies with the requirements of CUPID-0.

15.
Waste Manag ; 25(9): 880-6, 2005.
Artículo en Inglés | MEDLINE | ID: mdl-16154731

RESUMEN

Our investigations deal with the identification and synthesis of volatile, odoriferous compounds contained in the exhaust gas of food factories and on the biodegradation of alkylpyrazines. Collection of odour emissions samples was performed with a gas sampler equipped with filter tubes containing the styrene-polymer SuperQ. After elution with solvents of different polarity, the extracts were analysed by GC/MS and chemical microreactions. Proposed structures were verified by comparison of analytical data with those of synthetic reference samples. Major components in the exhaust gas of a fat finishing factory were found to be aliphatic aldehydes, strongly dominated by hexanal. The identification of 1,2,3,3-tetramethylcyclohexene shows that for structural proof of target compounds the use of authentic reference samples is indispensable. In the exhaust gas from a chocolate factory, several carbonyl compounds and alkylated pyrazines could be identified. Biodegradation of the latter starts with hydrogenation at the nucleus.


Asunto(s)
Técnicas de Química Analítica/métodos , Monitoreo del Ambiente/métodos , Industria de Alimentos , Odorantes/análisis , Compuestos Orgánicos/análisis , Residuos/análisis , Cacao/química , Cromatografía de Gases y Espectrometría de Masas , Compuestos Orgánicos/química , Volatilización
16.
Eur Phys J C Part Fields ; 75(1): 12, 2015.
Artículo en Inglés | MEDLINE | ID: mdl-25983645

RESUMEN

CUORE, an array of 988 TeO[Formula: see text] bolometers, is about to be one of the most sensitive experiments searching for neutrinoless double-beta decay. Its sensitivity could be further improved by removing the background from [Formula: see text] radioactivity. A few years ago it was pointed out that the signal from [Formula: see text]s can be tagged by detecting the emitted Cherenkov light, which is not produced by [Formula: see text]s. In this paper we confirm this possibility. For the first time we measured the Cherenkov light emitted by a CUORE crystal, and found it to be 100 eV at the [Formula: see text]-value of the decay. To completely reject the [Formula: see text] background, we compute that one needs light detectors with baseline noise below 20 eV RMS, a value which is 3-4 times smaller than the average noise of the bolometric light detectors we are using. We point out that an improved light detector technology must be developed to obtain TeO[Formula: see text] bolometric experiments able to probe the inverted hierarchy of neutrino masses.

17.
Artículo en Inglés | MEDLINE | ID: mdl-26705394

RESUMEN

The LUCIFER project aims at deploying the first array of enriched scintillating bolometers for the investigation of neutrinoless double-beta decay of [Formula: see text]Se. The matrix which embeds the source is an array of ZnSe crystals, where enriched [Formula: see text]Se is used as decay isotope. The radiopurity of the initial components employed for manufacturing crystals, that can be operated as bolometers, is crucial for achieving a null background level in the region of interest for double-beta decay investigations. In this work, we evaluated the radioactive content in 2.5 kg of 96.3 % enriched [Formula: see text]Se metal, measured with a high-purity germanium detector at the Gran Sasso deep underground laboratory. The limits on internal contaminations of primordial decay chain elements of [Formula: see text]Th, [Formula: see text]U and [Formula: see text]U are respectively: [Formula: see text]61, [Formula: see text]110 and [Formula: see text]74 [Formula: see text]Bq/kg at 90 % C.L. The extremely low-background conditions in which the measurement was carried out and the high radiopurity of the [Formula: see text]Se allowed us to establish the most stringent lower limits on the half-lives of the double-beta decay of [Formula: see text]Se to 0[Formula: see text], 2[Formula: see text] and 2[Formula: see text] excited states of [Formula: see text]Kr of 3.4[Formula: see text]10[Formula: see text], 1.3[Formula: see text]10[Formula: see text] and 1.0[Formula: see text]10[Formula: see text] y, respectively, with a 90 % C.L.

SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA