Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 3 de 3
Filtrar
1.
Am J Physiol Lung Cell Mol Physiol ; 313(2): L305-L312, 2017 08 01.
Artículo en Inglés | MEDLINE | ID: mdl-28473321

RESUMEN

During lung inflation, airspace dimensions are affected nonlinearly by both alveolar expansion and recruitment, potentially confounding the identification of emphysematous lung by hyperpolarized helium-3 diffusion magnetic resonance imaging (HP MRI). This study aimed to characterize lung inflation over a broad range of inflation volume and pressure values in two different models of emphysema, as well as in normal lungs. Elastase-treated rats (n = 7) and healthy controls (n = 7) were imaged with HP MRI. Gradual inflation was achieved by incremental changes to both inflation volume and airway pressure. The apparent diffusion coefficient (ADC) was measured at each level of inflation and fitted to the corresponding airway pressures as the second-order response equation, with minimizing residue (χ2 < 0.001). A biphasic ADC response was detected, with an initial ADC increase followed by a decrease at airway pressures >18 cmH2O. Discrimination between treated and control rats was optimal when airway pressure was intermediate (between 10 and 11 cmH2O). Similar findings were confirmed in mice following long-term exposure to cigarette smoke, where optimal discrimination between treated and healthy mice occurred at a similar airway pressure as in the rats. We subsequently explored the evolution of ADC measured at the intermediate inflation level in mice after prolonged smoke exposure and found a significant increase (P < 0.01) in ADC over time. Our results demonstrate that measuring ADC at intermediate inflation enhances the distinction between healthy and diseased lungs, thereby establishing a model that may improve the diagnostic accuracy of future HP gas diffusion studies.


Asunto(s)
Pulmón/patología , Enfisema Pulmonar/patología , Animales , Imagen de Difusión por Resonancia Magnética/métodos , Modelos Animales de Enfermedad , Helio/química , Ratones , Ratones Endogámicos C57BL , Elastasa Pancreática/administración & dosificación , Presión , Ratas , Ratas Sprague-Dawley , Humo/efectos adversos
2.
Magn Reson Med ; 78(2): 611-624, 2017 08.
Artículo en Inglés | MEDLINE | ID: mdl-27734519

RESUMEN

PURPOSE: To present a method for simultaneous acquisition of alveolar oxygen tension (PA O2 ), specific ventilation (SV), and apparent diffusion coefficient (ADC) of hyperpolarized (HP) gas in the human lung, allowing reinterpretation of the PA O2 and SV maps to produce a map of oxygen uptake (R). METHOD: An imaging scheme was designed with a series of identical normoxic HP gas wash-in breaths to measure ADC, SV, PA O2 , and R in less than 2 min. Signal dynamics were fit to an iterative recursive model that regionally solved for these parameters. This measurement was successfully performed in 12 subjects classified in three healthy, smoker, and chronic obstructive pulmonary disease (COPD) cohorts. RESULTS: The overall whole lung ADC, SV, PA O2 , and R in healthy, smoker, and COPD subjects was 0.20 ± 0.03 cm2 /s, 0.39 ± 0.06,113 ± 2 Torr, and 1.55 ± 0.35 Torr/s, respectively, in healthy subjects; 0.21 ± 0.03 cm2 /s, 0.33 ± 0.06, 115.9 ± 4 Torr, and 0.97 ± 0.2 Torr/s, respectively, in smokers; and 0.25 ± 0.06 cm2 /s, 0.23 ± 0.08, 114.8 ± 6.0Torr, and 0.94 ± 0.12 Torr/s, respectively, in subjects with COPD. Hetrogeneity of SV, PA O2 , and R were indicators of both smoking-related changes and disease, and the severity of the disease correlated with the degree of this heterogeneity. Subjects with symptoms showed reduced oxygen uptake and specific ventilation. CONCLUSION: High-resolution, nearly coregistered and quantitative measures of lung function and structure were obtained with less than 1 L of HP gas. This hybrid multibreath technique produced measures of lung function that revealed clear differences among the cohorts and subjects and were confirmed by correlations with global lung measurements. Magn Reson Med 78:611-624, 2017. © 2016 International Society for Magnetic Resonance in Medicine.


Asunto(s)
Procesamiento de Imagen Asistido por Computador/métodos , Imagen por Resonancia Magnética/métodos , Oxígeno/metabolismo , Alveolos Pulmonares/diagnóstico por imagen , Alveolos Pulmonares/metabolismo , Tritio/metabolismo , Adulto , Contencion de la Respiración , Femenino , Humanos , Masculino , Persona de Mediana Edad , Enfermedad Pulmonar Obstructiva Crónica/diagnóstico por imagen , Respiración
3.
J Clin Endocrinol Metab ; 103(1): 105-114, 2018 01 01.
Artículo en Inglés | MEDLINE | ID: mdl-29190340

RESUMEN

Context: Patients with long-standing type 1 diabetes (T1D) are at increased risk for severe hypoglycemia because of defects in glucose counterregulation and recognition of hypoglycemia symptoms, in part mediated through exposure to hypoglycemia. Objective: To determine whether implementation of real-time continuous glucose monitoring (CGM) as a strategy for hypoglycemia avoidance could improve glucose counterregulation in patients with long-standing T1D and hypoglycemia unawareness. Design, Setting, Participants, and Intervention: Eleven patients with T1D disease duration of ∼31 years were studied longitudinally in the Clinical & Translational Research Center of the University of Pennsylvania before and 6 and 18 months after initiation of CGM and were compared with 12 nondiabetic control participants. Main Outcome Measure: Endogenous glucose production response derived from paired hyperinsulinemic stepped-hypoglycemic and euglycemic clamps with infusion of 6,6-2H2-glucose. Results: In patients with T1D, hypoglycemia awareness (Clarke score) and severity (HYPO score and severe events) improved (P < 0.01 for all) without change in hemoglobin A1c (baseline, 7.2% ± 0.2%). In response to insulin-induced hypoglycemia, endogenous glucose production did not change from before to 6 months (0.42 ± 0.08 vs 0.54 ± 0.07 mg·kg-1·min-1) but improved after 18 months (0.84 ± 0.15 mg·kg-1·min-1; P < 0.05 vs before CGM), albeit remaining less than in controls (1.39 ± 0.11 mg·kg-1·min-1; P ≤ 0.01 vs all). Conclusions: Real-time CGM can improve awareness and reduce the burden of problematic hypoglycemia in patients with long-standing T1D, but with only modest improvement in the endogenous glucose production response that is required to prevent or correct low blood glucose.


Asunto(s)
Biomarcadores/metabolismo , Diabetes Mellitus Tipo 1/complicaciones , Glucosa/metabolismo , Conocimientos, Actitudes y Práctica en Salud , Hipoglucemia/diagnóstico , Monitoreo Fisiológico/métodos , Adulto , Anciano , Diabetes Mellitus Tipo 1/tratamiento farmacológico , Femenino , Estudios de Seguimiento , Índice Glucémico , Humanos , Hipoglucemia/etiología , Hipoglucemia/metabolismo , Hipoglucemiantes/uso terapéutico , Insulina/metabolismo , Secreción de Insulina , Estudios Longitudinales , Masculino , Persona de Mediana Edad , Pronóstico
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA