1.
AJR Am J Roentgenol ; 217(4): 908-918, 2021 10.
Artículo en Inglés | MEDLINE | ID: mdl-33336582

RESUMEN

BACKGROUND. In-gantry MRI-guided biopsy (MRGB) of the prostate has been shown to be more accurate than other targeted prostate biopsy methods. However, the optimal number of cores to obtain during in-gantry MRGB remains undetermined. OBJECTIVE. The purpose of this study was to assess the diagnostic yield of obtaining an incremental number of cores from the primary lesion and of second lesion sampling during in-gantry MRGB of the prostate. METHODS. This retrospective study included 128 men with 163 prostate lesions who underwent in-gantry MRGB between 2016 and 2019. The men had a total of 163 lesions sampled with two or more cores, 121 lesions sampled with three or more cores, and 52 lesions sampled with four or more cores. A total of 40 men underwent sampling of a second lesion. Upgrade on a given core was defined as a greater International Society of Urological Pathology (ISUP) grade group (GG) relative to the previously obtained cores. Clinically significant prostate cancer (csPCa) was defined as ISUP GG 2 or greater. RESULTS. The frequency of any upgrade was 12.9% (21/163) on core 2 versus 10.7% (13/121) on core 3 (p = .29 relative to core 2) and 1.9% (1/52) on core 4 (p = .03 relative to core 3). The frequency of upgrade to csPCa was 7.4% (12/163) on core 2 versus 4.1% (5/121) on core 3 (p = .13 relative to core 2) and 0% (0/52) on core 4 (p = .07 relative to core 3). The frequency of upgrade on core 2 was higher for anterior lesions (p < .001) and lesions with a higher PI-RADS score (p = .007); the frequency of upgrade on core 3 was higher for apical lesions (p = .01) and lesions with a higher PI-RADS score (p = .01). Sampling of a second lesion resulted in an upgrade in a single patient (2.5%; 1/40); both lesions were PI-RADS category 4 and showed csPCa. CONCLUSION. When performing in-gantry MRGB of the prostate, obtaining three cores from the primary lesion is warranted to optimize csPCa diagnosis. Obtaining a fourth core from the primary lesion or sampling a second lesion has very low yield in upgrading cancer diagnoses. CLINICAL IMPACT. To reduce patient discomfort and procedure times, operators may refrain from obtaining more than three cores or second lesion sampling.


Asunto(s)
Biopsia con Aguja Gruesa/métodos , Biopsia Guiada por Imagen/métodos , Imagen por Resonancia Magnética Intervencional/métodos , Neoplasias de la Próstata/diagnóstico por imagen , Neoplasias de la Próstata/patología , Anciano , Humanos , Masculino , Persona de Mediana Edad , Clasificación del Tumor , Estudios Retrospectivos
2.
J Ultrasound Med ; 40(8): 1479-1483, 2021 Aug.
Artículo en Inglés | MEDLINE | ID: mdl-33098581

RESUMEN

The Sound Judgment Series consists of invited articles highlighting the clinical value of using ultrasound first in specific clinical diagnoses where ultrasound has shown comparative or superior value. The series is meant to serve as an educational tool for medical and sonography students and clinical practitioners and may help integrate ultrasound into clinical practice.


Asunto(s)
Anticonceptivos , Implantes de Medicamentos , Humanos , Ultrasonografía
3.
Radiology ; 292(3): 685-694, 2019 09.
Artículo en Inglés | MEDLINE | ID: mdl-31335285

RESUMEN

BackgroundPreliminary studies have shown that MR fingerprinting-based relaxometry combined with apparent diffusion coefficient (ADC) mapping can be used to differentiate normal peripheral zone from prostate cancer and prostatitis. The utility of relaxometry and ADC mapping for the transition zone (TZ) is unknown.PurposeTo evaluate the utility of MR fingerprinting combined with ADC mapping for characterizing TZ lesions.Materials and MethodsTZ lesions that were suspicious for cancer in men who underwent MRI with T2-weighted imaging and ADC mapping (b values, 50-1400 sec/mm2), MR fingerprinting with steady-state free precession, and targeted biopsy (60 in-gantry and 15 cognitive targeting) between September 2014 and August 2018 in a single university hospital were retrospectively analyzed. Two radiologists blinded to Prostate Imaging Reporting and Data System (PI-RADS) scores and pathologic diagnosis drew regions of interest on cancer-suspicious lesions and contralateral visually normal TZs (NTZs) on MR fingerprinting and ADC maps. Linear mixed models compared two-reader means of T1, T2, and ADC. Generalized estimating equations logistic regression analysis was used to evaluate both MR fingerprinting and ADC in differentiating NTZ, cancers and noncancers, clinically significant (Gleason score ≥ 7) cancers from clinically insignificant lesions (noncancers and Gleason 6 cancers), and characterizing PI-RADS version 2 category 3 lesions.ResultsIn 67 men (mean age, 66 years ± 8 [standard deviation]) with 75 lesions, targeted biopsy revealed 37 cancers (six PI-RADS category 3 cancers and 31 PI-RADS category 4 or 5 cancers) and 38 noncancers (31 PI-RADS category 3 lesions and seven PI-RADS category 4 or 5 lesions). The T1, T2, and ADC of NTZ (1800 msec ± 150, 65 msec ± 22, and [1.13 ± 0.19] × 10-3 mm2/sec, respectively) were higher than those in cancers (1450 msec ± 110, 36 msec ± 11, and [0.57 ± 0.13] × 10-3 mm2/sec, respectively; P < .001 for all). The T1, T2, and ADC in cancers were lower than those in noncancers (1620 msec ± 120, 47 msec ± 16, and [0.82 ± 0.13] × 10-3 mm2/sec, respectively; P = .001 for T1 and ADC and P = .03 for T2). The area under the receiver operating characteristic curve (AUC) for T1 plus ADC was 0.94 for separation. T1 and ADC in clinically significant cancers (1440 msec ± 140 and [0.58 ± 0.14] × 10-3 mm2/sec, respectively) were lower than those in clinically insignificant lesions (1580 msec ± 120 and [0.75 ± 0.17] × 10-3 mm2/sec, respectively; P = .001 for all). The AUC for T1 plus ADC was 0.81 for separation. Within PI-RADS category 3 lesions, T1 and ADC of cancers (1430 msec ± 220 and [0.60 ± 0.17] × 10-3 mm2/sec, respectively) were lower than those of noncancers (1630 msec ± 120 and [0.81 ± 0.13] × 10-3 mm2/sec, respectively; P = .006 for T1 and P = .004 for ADC). The AUC for T1 was 0.79 for differentiating category 3 lesions.ConclusionMR fingerprinting-based relaxometry combined with apparent diffusion coefficient mapping may improve transition zone lesion characterization.© RSNA, 2019Online supplemental material is available for this article.


Asunto(s)
Imagen por Resonancia Magnética/métodos , Neoplasias de la Próstata/diagnóstico por imagen , Prostatitis/diagnóstico por imagen , Anciano , Diagnóstico Diferencial , Humanos , Masculino , Próstata/diagnóstico por imagen , Reproducibilidad de los Resultados , Estudios Retrospectivos
4.
J Ultrasound Med ; 38(10): 2541-2557, 2019 Oct.
Artículo en Inglés | MEDLINE | ID: mdl-30714653

RESUMEN

Since its introduction, contrast-enhanced ultrasound (CEUS) has gained an important role in the diagnosis and management of abdominal and pelvic diseases. Contrast-enhanced ultrasound can improve lesion detection rates as well as success rates of interventional procedures when compared to conventional ultrasound alone. Additionally, CEUS enables the interventionalist to assess the dynamic enhancement of different tissues and lesions, without the adverse effects of contrast-enhanced computed tomography, such as exposure to ionizing radiation and nephrotoxicity from iodinated contrast material. This review article describes the various applications and advantages of the use of CEUS to enhance performance of ultrasound-guided interventions in the abdomen and pelvis.


Asunto(s)
Medios de Contraste , Enfermedades del Sistema Digestivo/diagnóstico por imagen , Enfermedades Urogenitales Femeninas/diagnóstico por imagen , Aumento de la Imagen/métodos , Enfermedades Urogenitales Masculinas/diagnóstico por imagen , Enfermedades del Bazo/diagnóstico por imagen , Ultrasonografía Intervencional/métodos , Abdomen/diagnóstico por imagen , Femenino , Humanos , Masculino , Pelvis/diagnóstico por imagen
5.
Pediatr Radiol ; 47(6): 755-760, 2017 May.
Artículo en Inglés | MEDLINE | ID: mdl-28213627

RESUMEN

Real-time MRI-guided percutaneous sclerotherapy is a novel and evolving treatment for congenital lymphatic malformations in the head and neck. We elaborate on the specific steps necessary to perform an MRI-guided percutaneous sclerotherapy of lymphatic malformations including pre-procedure patient work-up and preparation, stepwise intraprocedural interventional techniques and post-procedure management. Based on our institutional experience, MRI-guided sclerotherapy with a doxycycline-gadolinium-based mixture as a sclerosant for lymphatic malformations of the head and neck region in children is well tolerated and effective.


Asunto(s)
Anomalías Linfáticas/terapia , Imagen por Resonancia Magnética Intervencional , Soluciones Esclerosantes/uso terapéutico , Escleroterapia/métodos , Adolescente , Niño , Medios de Contraste/uso terapéutico , Doxiciclina/uso terapéutico , Femenino , Cabeza , Humanos , Masculino , Cuello , Resultado del Tratamiento
6.
J Vasc Interv Radiol ; 27(12): 1907-1912, 2016 Dec.
Artículo en Inglés | MEDLINE | ID: mdl-27567997

RESUMEN

PURPOSE: To evaluate the imaging, histologic changes and safety of computed tomography (CT)-guided cryoablation of the parotid glands in a porcine model. MATERIALS AND METHODS: Unilateral CT-guided parotid gland cryoablation was performed in 5 juvenile miniature pigs. The ablated parotid glands underwent 2 cycles of 10-minute freeze and 5-minute thaw using three 17-g cryoprobes. The animals were monitored daily for complications including pain, frostbite, infection, and sialocele or fistula formation. Follow-up CT was performed at 6 weeks postcryoablation. Pathologic evaluation was performed on 2 of the ablated parotid glands. RESULTS: All cryoablations in 5 right parotid glands, with 3 sites in each gland, were technically successful. No symptoms suggestive of facial nerve damage were observed during 6-week follow-up. One pig developed an infected sialocele, which was treated with percutaneous drainage and oral antibiotic therapy. No CT evidence of sialocele or other abnormality was identified at the 6-week follow-up in all pigs. Histologic evaluation was performed on 2 of the parotid gland specimens, 1 with the treated sialocele, and 1 of the remaining pigs without sialocele. Both glands demonstrated postprocedural intraglandular lymph nodes and reactive changes without evidence of sialocele or abscess on histopathology. CONCLUSIONS: Cryoablation of parotid glands was technically feasible in a porcine model. Only 1 pig developed sialocele, which was successfully treated. Further research is warranted to determine the potential use of salivary gland cryoablation to treat patients with drooling.


Asunto(s)
Criocirugía , Glándula Parótida/cirugía , Radiografía Intervencional/métodos , Sialorrea/cirugía , Tomografía Computarizada por Rayos X , Animales , Biopsia , Criocirugía/efectos adversos , Estudios de Factibilidad , Femenino , Modelos Animales , Glándula Parótida/diagnóstico por imagen , Glándula Parótida/patología , Glándula Parótida/fisiopatología , Radiografía Intervencional/efectos adversos , Salivación , Sialorrea/fisiopatología , Porcinos , Porcinos Enanos , Factores de Tiempo , Tomografía Computarizada por Rayos X/efectos adversos
7.
J Ultrasound Med ; 35(6): 1131-41, 2016 Jun.
Artículo en Inglés | MEDLINE | ID: mdl-27091917

RESUMEN

OBJECTIVES: To compare the diagnostic yield, complication rate, and procedure length of ultrasound fusion-guided liver biopsy to the diagnostic yield, complication rate, and procedure length of computed tomography (CT)-guided liver biopsy; to measure the average ionizing radiation dose that patients are exposed to during a typical CT-guided liver biopsy procedure; and to present relevant and interesting cases of ultrasound fusion-guided abdominal interventions to describe the efficacious use of the technology. METHODS: A retrospective analysis of 63 patients who had image-guided liver biopsies performed at our institution was completed. Patient records were divided into 2 groups according to the type of image guidance used during the procedure (ultrasound fusion versus CT), and data were compared by the χ(2) test, Student t test, and Mann-Whitney U test. RESULTS: The diagnostic yields and complication rates were not statistically significantly different between the modalities. The average procedure durations were significantly different: ultrasound fusion-guided biopsy, 31.63 minutes; compared to CT-guided biopsy, 61.67 minutes (P = .003). CONCLUSIONS: Diagnostic yields and complication rates were comparable for ultrasound fusion and CT. However, the average procedure duration for an ultrasound fusion-guided liver biopsy was approximately half that of CT-guided liver biopsy, likely increasing both cost-effectiveness and patient satisfaction.


Asunto(s)
Hígado/diagnóstico por imagen , Hígado/patología , Imagen por Resonancia Magnética/métodos , Imagen Multimodal/métodos , Tomografía Computarizada por Rayos X/métodos , Ultrasonografía Intervencional/métodos , Abdomen/diagnóstico por imagen , Abdomen/patología , Adulto , Anciano , Anciano de 80 o más Años , Biopsia con Aguja , Femenino , Humanos , Biopsia Guiada por Imagen/métodos , Masculino , Persona de Mediana Edad , Dosis de Radiación , Reproducibilidad de los Resultados , Estudios Retrospectivos
8.
Magn Reson Med ; 71(6): 2243-9, 2014 Jun.
Artículo en Inglés | MEDLINE | ID: mdl-23900921

RESUMEN

PURPOSE: A prototype wireless guidance device using single sideband amplitude modulation (SSB) is presented for a 1.5T magnetic resonance imaging system. METHODS: The device contained three fiducial markers each mounted to an independent receiver coil equipped with wireless SSB technology. Acquiring orthogonal projections of these markers determined the position and orientation of the device, which was used to define the scan plane for a subsequent image acquisition. Device localization and scan plane update required approximately 30 ms, so it could be interleaved with high temporal resolution imaging. Since the wireless device is used for localization and does not require full imaging capability, the design of the SSB wireless system was simplified by allowing an asynchronous clock between the transmitter and receiver. RESULTS: When coupled to a high readout bandwidth, the error caused by the lack of a shared frequency reference was quantified to be less than one pixel (0.78 mm) in the projection acquisitions. Image guidance with the prototype was demonstrated with a phantom where a needle was successfully guided to a target and contrast was delivered. CONCLUSION: The feasibility of active tracking with a wireless detector array is demonstrated. Wireless arrays could be incorporated into devices to assist in image-guided procedures.


Asunto(s)
Marcadores Fiduciales , Imagen por Resonancia Magnética/instrumentación , Tecnología Inalámbrica , Diseño de Equipo , Estudios de Factibilidad , Fantasmas de Imagen
9.
J Magn Reson Imaging ; 39(1): 189-94, 2014 Jan.
Artículo en Inglés | MEDLINE | ID: mdl-24123420

RESUMEN

PURPOSE: To evaluate image quality when using a CAIPIRINHA sampling pattern in comparison to a standard GRAPPA sampling pattern in patients undergoing a routine three-dimensional (3D) breathheld liver exam. CAIPIRINHA uses an optimized phase encoding sampling strategy to alter aliasing artifacts in 3D acquisitions to improve parallel imaging reconstruction. MATERIALS AND METHODS: Twenty patient volunteers were scanned using a 3D VIBE acquisition with an acceleration factor of four using a CAIPIRINHA and standard GRAPPA sampling pattern. CAIPIRINHA and GRAPPA images were evaluated by three radiologists in a two alternative forced choice test, and the Wilcoxon signed rank test was performed. RESULTS: The CAIPIRINHA sampling pattern was preferred in an average of 68% of the comparisons, and the Wilcoxon signed rank test showed a significant improvement in CAIPIRINHA images (P = 0.014). This analysis indicates that in the given sample set, CAIPIRINHA preference over the GRAPPA standard was statistically significant. CONCLUSION: This work shows that for an acceleration factor of four, a CAIPIRINHA accelerated VIBE acquisition provides significantly improved image quality in comparison to the current GRAPPA standard. This allows a further reduction in imaging time for similar spatial resolutions, which can reduce long breathhold requirements in abdominal imaging, and may be particularly helpful in patients who cannot provide requisite breathholds with current protocols.


Asunto(s)
Abdomen/patología , Aumento de la Imagen/métodos , Procesamiento de Imagen Asistido por Computador/métodos , Imagenología Tridimensional/métodos , Imagen por Resonancia Magnética/métodos , Adulto , Anciano , Anciano de 80 o más Años , Algoritmos , Artefactos , Contencion de la Respiración , Medios de Contraste/química , Humanos , Imagenología Tridimensional/normas , Hígado/patología , Imagen por Resonancia Magnética/normas , Persona de Mediana Edad , Variaciones Dependientes del Observador , Programas Informáticos , Factores de Tiempo , Adulto Joven
10.
Abdom Radiol (NY) ; 49(4): 1223-1230, 2024 04.
Artículo en Inglés | MEDLINE | ID: mdl-38383816

RESUMEN

PURPOSE: To describe the technique and evaluate the performance of MRI-guided transgluteal in-bore-targeted biopsy of the prostate gland under local anesthesia in patients without rectal access. METHODS: Ten men (mean age, 69 (range 57-86) years) without rectal access underwent 13 MRI-guided transgluteal in-bore-targeted biopsy of the prostate gland under local anesthesia. All patients underwent mp-MRI at our institute prior to biopsy. Three patients had prior US-guided transperineal biopsy which was unsuccessful in one, negative in one, and yielded GG1 (GS6) PCa in one. Procedure time, complications, histopathology result, and subsequent management were recorded. RESULTS: Median interval between rectal surgery and presentation with elevated PSA was 12.5 years (interquartile range (IQR) 25-75, 8-36.5 years). Mean PSA was 11.9 (range, 4.8 -59.0) ng/ml and PSA density was 0.49 (0.05 -3.2) ng/ml/ml. Distribution of PI-RADS v2.0/2.1 scores of the targeted lesions were PI-RADS 5-3; PI-RADS 4-6; and PI-RADS 3-1. Mean lesion size was 1.5 cm (range, 1.0-3.6 cm). Median interval between MRI and biopsy was 5.5 months (IQR 25-75, 1.5-9 months). Mean procedure time was 47.4 min (range, 29-80 min) and the number of cores varied between 3 and 5. Of the 13 biopsies, 4 yielded clinically significant prostate cancer (csPca), with a Gleason score ≥ 7, 1 yielded insignificant prostate cancer (Gleason score = 6), 7 yielded benign prostatic tissue, and one was technically unsuccessful. 3/13 biopsies were repeat biopsies which detected csPCa in 2 out of the 3 patients. None of the patients had biopsy-related complication. Biopsy result changed management to radiation therapy with ADT in 2 patients with the rest on active surveillance. CONCLUSION: MRI-guided transgluteal in-bore-targeted biopsy of the prostate gland under local anesthesia is feasible in patients without rectal access.


Asunto(s)
Imagen por Resonancia Magnética Intervencional , Neoplasias de la Próstata , Masculino , Humanos , Persona de Mediana Edad , Anciano , Anciano de 80 o más Años , Neoplasias de la Próstata/diagnóstico por imagen , Neoplasias de la Próstata/cirugía , Neoplasias de la Próstata/patología , Próstata/diagnóstico por imagen , Próstata/patología , Imagen por Resonancia Magnética/métodos , Antígeno Prostático Específico , Anestesia Local , Biopsia Guiada por Imagen/métodos , Imagen por Resonancia Magnética Intervencional/métodos , Estudios Retrospectivos
11.
J Magn Reson Imaging ; 38(5): 1237-44, 2013 Nov.
Artículo en Inglés | MEDLINE | ID: mdl-23389970

RESUMEN

PURPOSE: To obtain a simultaneous 3D magnetic resonance angiography and perfusion (MRAP) using a single acquisition and to demonstrate MRAP in the lower extremities. A time-resolved contrast-enhanced exam was used in MRAP to simultaneously acquire a contrast-enhanced MR angiography (MRA) and dynamic contrast-enhanced (DCE) perfusion, which currently requires separate acquisitions and thus two contrast doses. MRAP can be used to assess large and small vessels in vascular pathologies such as peripheral arterial disease. MATERIALS AND METHODS: MRAP was performed on 10 volunteers following unilateral plantar flexion exercise (one leg exercised and one rested) on two separate days. Data were acquired after administration of a single dose of contrast agent using an optimized sampling strategy, parallel imaging, and partial-Fourier acquisition to obtain a high spatial resolution, 3D-MRAP frame every 4 seconds. Two radiologists assessed MRAs for image quality, a signal-to-noise ratio (SNR) analysis was performed, and pharmacokinetic modeling yielded perfusion (K(trans) ). RESULTS: MRA images had high SNR and radiologist-assessed diagnostic quality. Mean K(trans) ± standard error were 0.136 ± 0.009, 0.146 ± 0.012, and 0.191 ± 0.012 min(-1) in the resting tibialis anterior, gastrocnemius, and soleus, respectively, which significantly increased with exercise to 0.291 ± 0.018, 0.270 ± 0.019, and 0.338 ± 0.022 min(-1) . Bland-Altman analysis showed good repeatability. CONCLUSION: MRAP provides simultaneous high-resolution MRA and quantitative DCE exams to assess large and small vessels with a single contrast dose. Application in skeletal muscle shows quantitative, repeatable perfusion measurements, and the ability to measure physiological differences.


Asunto(s)
Interpretación de Imagen Asistida por Computador/métodos , Extremidad Inferior/fisiología , Imagen por Resonancia Magnética/métodos , Imagen Multimodal/métodos , Músculo Esquelético/fisiología , Adulto , Velocidad del Flujo Sanguíneo/fisiología , Femenino , Humanos , Extremidad Inferior/irrigación sanguínea , Masculino , Músculo Esquelético/irrigación sanguínea , Proyectos Piloto , Reproducibilidad de los Resultados , Sensibilidad y Especificidad
12.
Urol Int ; 90(4): 381-3, 2013.
Artículo en Inglés | MEDLINE | ID: mdl-23594736

RESUMEN

INTRODUCTION: Percutaneous cryoablation is an emerging treatment option for the small renal mass. It poses a risk of thermal injury to adjacent tissues, limiting its application. We describe pneumodissection, a novel technique for preventing thermal injury during percutaneous cryoablation. MATERIALS AND METHODS: The cases of 4 patients who underwent percutaneous renal cryoablation and pneumodissection were retrospectively reviewed. RESULTS: Pneumodissection mechanically separated four tumors from overlying bowel segments (mean distance 1.2 ± 0.4 cm), permitting successful cryoablation. There were no complications or recurrences with 7.5 months of follow-up. CONCLUSIONS: Pneumodissection is a feasible displacement technique that facilitates percutaneous cryoablation in at-risk patients. Further study is warranted.


Asunto(s)
Criocirugía/métodos , Disección/métodos , Neoplasias Renales/cirugía , Anciano , Criocirugía/efectos adversos , Disección/efectos adversos , Estudios de Factibilidad , Humanos , Neoplasias Renales/diagnóstico por imagen , Neoplasias Renales/patología , Complicaciones Posoperatorias/prevención & control , Radiografía Intervencional , Estudios Retrospectivos , Factores de Riesgo , Tomografía Computarizada por Rayos X , Resultado del Tratamiento , Carga Tumoral
13.
Int J Urol ; 20(6): 580-4, 2013 Jun.
Artículo en Inglés | MEDLINE | ID: mdl-23190309

RESUMEN

OBJECTIVE: To further evaluate the accuracy, safety, and impact of image-guided renal biopsies on clinical decision making and management of the indeterminate small renal masses. METHODS: A total of 145 patients (males 99, females 46) with small renal masses suspicious for malignancy were evaluated during the study period. The patients' mean age was 67.2 (± 11.6) years. Computed tomography guided biopsies were carried out in all cases by an experienced interventional radiologist. An experienced genitourinary pathologist reviewed all pathological specimens. Patients' demographic characteristics, tumor histology and subsequent intervention, as well as periprocedural morbidities were recorded and analyzed. RESULTS: A total of 145 renal biopsy procedures were carried out. The small renal masses mean size was 2.4 ± 1.1 cm. Biopsy was diagnostic in 126 (86.9%) cases and non-diagnostic in 19 (13.1%) cases. Of diagnostic biopsies, 107 (84.9%) were malignant, 84.1% of which were primary renal cell carcinoma. Histological subtyping and grading of tumor was possible in 100% and 52.2% of renal cell carcinomas, respectively. The major renal cell carcinoma subtype was clear cell (63.3%) followed by papillary (24.4%) and chromophobe (8.8%). Repeat biopsy was carried out in nine of 19 non-diagnostic cases, and diagnosis was possible in 66.7%. Sensitivity of percutaneous renal biopsy was 91%, and its accuracy was 85.5%. Overall, patients' age, sex, tumor size, and location were not related to non-diagnostic biopsy results and/or tumor pathology. No cases of hemorrhage, seeding of biopsy tract, infection or mortalities were observed. CONCLUSIONS: Our findings showed that image-guided biopsy of indeterminate small renal masses is safe and can provide the correct diagnosis with a high degree of accuracy. Thus, this procedure can play an important role in establishing a histopathological diagnosis before treatment of enhancing small renal masses with ablative technologies. Furthermore, repeat biopsy can alter the clinical management of non-diagnostic biopsies.


Asunto(s)
Carcinoma de Células Renales/patología , Neoplasias Renales/patología , Riñón/patología , Anciano , Carcinoma de Células Renales/diagnóstico por imagen , Femenino , Humanos , Biopsia Guiada por Imagen/efectos adversos , Riñón/diagnóstico por imagen , Neoplasias Renales/diagnóstico por imagen , Masculino , Persona de Mediana Edad , Radiografía Intervencional , Estudios Retrospectivos
14.
J Vasc Interv Radiol ; 22(11): 1601-5, 2011 Nov.
Artículo en Inglés | MEDLINE | ID: mdl-21924625

RESUMEN

PURPOSE: To evaluate the effectiveness of direct intraparenchymal injection of platelets or fresh frozen plasma (FFP) into the needle tract before cutting needle biopsy to decrease postprocedural blood loss in pigs with normal and abnormal hemostasis. MATERIALS AND METHODS: A total of 12 Yorkshire-cross pigs were anesthetized and maintained on a respirator. The pigs were divided into three groups: three with normal hemostasis, five treated with warfarin anticoagulation, and four treated with aspirin. Four types of biopsies were performed in the exposed livers and kidneys with 14-gauge Tru-Cut needles. The first was a standard (ie, control) biopsy, and the other three were performed with 2 mL normal saline solution, porcine FFP, or platelet-rich porcine plasma injected into the planned needle tract. Biopsy was then performed in the same needle tract. Blood loss was measured with gauze sponges. RESULTS: Significantly decreased postbiopsy blood loss was noted after FFP and platelet injection in the livers and kidneys of all groups except the kidney biopsy group after platelet injection in pigs with normal hemostasis. There was no significant difference in blood loss between the control and saline solution control groups in any of the pigs. CONCLUSIONS: Local injection of platelets or FFP significantly decreases postbiopsy blood loss in pigs with impaired hemostasis.


Asunto(s)
Biopsia con Aguja/efectos adversos , Plaquetas , Hemorragia/prevención & control , Hemostasis , Técnicas Hemostáticas , Plasma , Animales , Anticoagulantes/farmacología , Aspirina/farmacología , Plaquetas/efectos de los fármacos , Hemorragia/sangre , Hemorragia/etiología , Hemostasis/efectos de los fármacos , Inyecciones , Modelos Animales , Inhibidores de Agregación Plaquetaria/farmacología , Porcinos , Warfarina/farmacología
15.
Acad Radiol ; 25(12): 1617-1623, 2018 12.
Artículo en Inglés | MEDLINE | ID: mdl-29573937

RESUMEN

RATIONALE AND OBJECTIVES: To evaluate different techniques for reducing hemorrhagic complications in coagulopathic patients with elevated international normalized ratio having an image-guided percutaneous invasive procedure; techniques included systemic transfusion of fresh frozen plasma (FFP), local injection of FFP, percutaneous injection of gelatin sponge, and percutaneous placements of angiographic coils. MATERIALS AND METHODS: Retrospective review of 232 consecutive patients with known coagulopathy undergoing image-guided minimally invasive procedures were selected. Ninety-one patients had local FFP injected, 40 patients underwent local synthetic gelatin injection, 16 patients had percutaneous coil embolization, and 85 patients received systemic FFP. The number of bleeds, complications related to bleeds, and systemic complications were recorded. A 30 cc threshold was used to delineate significant bleeding. RESULTS: No patients experienced clinically significant or insignificant bleeding with local FFP injection (P value <.05). Other local hemostatic methods (Gelfoam, systemic FFP, and coil embolization) were associated with higher levels of bleeding (12.5%, 17.1%, 37.5%, respectively) and complications (7.5%, 31.4%, 37.5%, respectively). Systemic FFP infusion was associated with respiratory, infectious, and mortal complications. CONCLUSIONS: Local injection of blood products provides a safe and efficacious hemostatic agent to reduce the incidence of postprocedural bleeding. The technique is associated with lower rates of bleeding and systemic complications when compared to other local and systemic techniques. Further randomized prospective studies with a larger patient cohort need to be performed to corroborate these initial findings.


Asunto(s)
Pérdida de Sangre Quirúrgica/prevención & control , Embolización Terapéutica , Esponja de Gelatina Absorbible/uso terapéutico , Hemostasis Quirúrgica/métodos , Plasma , Hemorragia Posoperatoria/prevención & control , Trastornos de la Coagulación Sanguínea/complicaciones , Estudios de Cohortes , Embolización Terapéutica/efectos adversos , Femenino , Esponja de Gelatina Absorbible/efectos adversos , Hemostasis , Hemostasis Quirúrgica/efectos adversos , Humanos , Relación Normalizada Internacional , Masculino , Persona de Mediana Edad , Procedimientos Quirúrgicos Mínimamente Invasivos/efectos adversos , Transfusión de Plaquetas , Estudios Retrospectivos , Cirugía Asistida por Computador
16.
Cardiovasc Diagn Ther ; 8(Suppl 1): S118-S130, 2018 Apr.
Artículo en Inglés | MEDLINE | ID: mdl-29850424

RESUMEN

Ultrasound (US) represents the initial modality in the workup of abdominal aortic pathology based on the plethora of advantages including widespread availability, low cost, safety profile and repeatability. However, US has inherent limitations including limited spatial information of pathologic processes to neighboring structures, lower sensitivity to slow blood flow and aortic luminal irregularities. For evaluation of aortic pathology angiography has long been considered the gold standard. Non-invasive cross-sectional imaging techniques like computed tomography angiography (CTA) and magnetic resonance angiography (MRA) have gradually replaced interventional angiography for the evaluation of aorta, currently being regarded as the diagnostic imaging modalities of choice for diagnosis of virtually every aortic disease. Interventional angiography is currently primarily performed for treatment purposes of aortic pathology. The introduction of microbubbles as ultrasonographic contrast agents has rendered contrast-enhanced ultrasound (CEUS) an evolving valuable complementary technique with markedly increased diagnostic accuracy for certain aortic applications. CEUS is characterized by the potential to be performed in patients with impaired renal function. Due to its superior spatial and temporal resolution, ability for prolonged scanning and dynamic and real-time imaging, it provides clinically significant additional information compared to the standard Duplex US. The purpose of this paper is to discuss the currently available literature regarding abdominal aortic applications of CEUS, briefly elaborate on CEUS technique and safety and present cases in order to illustrate the added value in aortic pathologies. Conditions discussed include abdominal aortic aneurysm (AAA), aneurysm rupture, aneurysm surveillance after endovascular repair, dissection and aortitis.

17.
Phlebology ; 33(5): 344-352, 2018 Jun.
Artículo en Inglés | MEDLINE | ID: mdl-28516809

RESUMEN

Purpose This manuscript describes the technique of real-time MRI-guided sclerotherapy for low-flow venous malformations in the head and neck based on our institutional experience. Materials and methods Ethanolamine oleate is used as the sclerosant and is mixed with gadolinium for visualization during the procedure. The five procedural steps include: (I) an initial tri-plane T2-weighted sequence to visualize the lesion; (II) a T1 FSE or trueFISP sequence to assess needle placement and advancement within the lesion; (III) a tri-plane T1 FLASH sequence to monitor sclerosant injection; (IV) a T1 FSE or VIBE sequence to assess sclerosant coverage of the malformation before needle removal; (V) a post-procedural tri-plane T1 fat-saturated sequence to confirm sclerosant coverage of the lesion. Periprocedural medications typically include steroids, antibiotic prophylaxis, and non-steroidal anti-inflammatory medication. Patients are typically admitted for overnight observation. Conclusion Real-time MRI-guided sclerotherapy for low-flow venous malformations in the head and neck is effective and safe.


Asunto(s)
Imagen por Resonancia Magnética , Ácidos Oléicos/uso terapéutico , Soluciones Esclerosantes/uso terapéutico , Escleroterapia , Enfermedades Vasculares/terapia , Malformaciones Vasculares/diagnóstico por imagen , Malformaciones Vasculares/terapia , Adolescente , Antibacterianos/uso terapéutico , Antiinflamatorios no Esteroideos/uso terapéutico , Encéfalo/diagnóstico por imagen , Femenino , Gadolinio/química , Cabeza/diagnóstico por imagen , Cabeza/fisiopatología , Humanos , Persona de Mediana Edad , Cuello/diagnóstico por imagen , Cuello/fisiopatología , Esteroides/uso terapéutico , Procesos Estocásticos , Enfermedades Vasculares/diagnóstico por imagen
18.
AIDS ; 21(8): 921-7, 2007 May 11.
Artículo en Inglés | MEDLINE | ID: mdl-17457085

RESUMEN

OBJECTIVES: To assess carotid intima media thickness (IMT) and cardiac biomarkers in HIV infected children on antiretroviral therapy (ART). METHODS: This was a single site, cross sectional, controlled observational study. We assessed carotid IMT, homocysteine, high-sensitivity C-reactive protein and myeloperoxidase levels in HIV infected children on stable ART for >or= 6 months. Carotid IMT was reported as internal carotid artery (ICA) and common carotid artery (CCA) thickness; left and right sides were measured separately. Groups were compared using appropriate two-sample tests. RESULTS: Of the 62 subjects enrolled, 31 were HIV positive (50%), 66% were female, and 69% were African-American. Median CD4% was 32% and 26 patients (84%) had HIV-1 RNA< 400 copies/ml. Sixteen patients had been taking protease inhibitors for a median duration of 27 months. None had hypertension or smoked. HIV infected children had higher HOMA-IR, waist-to-hip ratio, cholesterol, triglycerides, myeloperoxidase and lower homocysteine levels. Left and right CCA IMT, and left and right ICA IMT were significantly higher in the HIV infected group. Significant predictors of carotid IMT measurements in uninfected controls were body mass index and homocysteine, but only the duration of ARV therapy was predictive of IMT in the HIV infected group. CONCLUSION: Higher levels of carotid IMT and some cardiac markers were found in ART treated HIV infected children when compared to matched uninfected controls. These results suggest that HIV infected children receiving ART may be at increased risk of cardiovascular disease.


Asunto(s)
Enfermedades Cardiovasculares/etiología , Arterias Carótidas/patología , Infecciones por VIH/patología , Túnica Íntima/patología , Túnica Media/patología , Adolescente , Adulto , Fármacos Anti-VIH/administración & dosificación , Fármacos Anti-VIH/efectos adversos , Terapia Antirretroviral Altamente Activa/efectos adversos , Biomarcadores/sangre , Composición Corporal , Proteína C-Reactiva/metabolismo , Enfermedades Cardiovasculares/sangre , Enfermedades Cardiovasculares/patología , Arterias Carótidas/diagnóstico por imagen , Arteria Carótida Común/patología , Arteria Carótida Interna/patología , Niño , Preescolar , Estudios Transversales , Esquema de Medicación , Femenino , Infecciones por VIH/sangre , Infecciones por VIH/complicaciones , Infecciones por VIH/tratamiento farmacológico , Homocisteína/sangre , Humanos , Lípidos/sangre , Masculino , Peroxidasa/sangre , Túnica Íntima/diagnóstico por imagen , Túnica Media/diagnóstico por imagen , Ultrasonografía
20.
Gastroenterol Rep (Oxf) ; 5(4): 305-308, 2017 11.
Artículo en Inglés | MEDLINE | ID: mdl-27694618

RESUMEN

OBJECTIVE: Portal pressure gradient (PPG) after transjugular intrahepatic portosystemic shunt (TIPS) <12 mmHg has been reported as the only factor predictive of increase in platelet count. As flow velocities measured on Doppler ultrasound are related to pressure gradient based on the Bernoulli equation, we used this parameter to predict increased platelet count after TIPS placement. METHODS: A total of 161 consecutive patients who underwent TIPS placement entered this retrospective study. The platelet count was measured before, one week after and one month after TIPS placement. Clinically significant thrombocytopenia was defined as platelet count ≤100 000. Pre- and post-TIPS PPGs were measured. The velocity of blood flow in the proximal, mid and distal TIPS stent was measured using Doppler ultrasound, and the difference in the highest and lowest measured velocity was entitled flow velocity gradient (FVG), which was considered normal when ≤100 cm/s. RESULTS: In 121 patients with pre-TIPS thrombocytopenia, the mean platelet count one week and one month after TIPS placement increased 25.7 x 103 and 35.0 x 103 in 90 patients with PPG≤12 mmHg (P=0.028 and P=0.015), while there was no significant change in platelet count in patients with a PPG >12 mmHg (P=0.098 and P=0.075). Platelets increased significantly when FVG≤ 100 cm/s (n=95) vs FVG >100 cm/s (n=26) one week (37.0x103 vs 11.0x103; P = 0.005 vs 0.07) and one month after TIPS placement (17.0x103 vs 5.2x103; P = 0.01 vs 0.21). CONCLUSION: FVG >100 cm/s is not associated with increase in post-TIPS platelet count. On the other hand, findings suggestive of proper TIPS function (FVG ≤100 cm/s and PPG≤ 12 mmHg) predict a significant increase in post-TIPS platelet count.