Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 1 de 1
Filtrar
Más filtros

Bases de datos
Tipo de estudio
País/Región como asunto
Tipo del documento
Asunto de la revista
País de afiliación
Intervalo de año de publicación
1.
PLoS One ; 18(3): e0282650, 2023.
Artículo en Inglés | MEDLINE | ID: mdl-36897841

RESUMEN

BACKGROUND: Proficiency testing (PT) has been hard to set up due to cost limitations and technical capacity. Conventional Xpert MTB/RIF PT programs use liquid and culture spots which require stringent storage and transportation conditions with cross-contamination chances prevalent. These setbacks prompted the use of dried tube specimens (DTS) for Ultra assay PT. For continuity of PT provision, stability of DTS and compatibility with testing protocols when kept for a long period needs to be established. METHODS: DTS were prepared from known isolates inactivated using a hot air oven at 85°C. 100µl of bacterial suspensions were aliquoted and dried inside a Biosafety cabinet. Panel validation was done to establish the baseline Deoxyribonucleic acid (DNA) concentration in terms of cycle threshold (Ct) value. DTS aliquots were shipped to participants to test and report within six weeks. The remaining DTS were kept at 2-8°C and room temperature for one year with testing at six months. Twenty (20) DTS samples per set remaining at one year were heated at 55°C for two weeks before testing. The means of the different samples were compared to validation data using paired t-tests. Boxplots were designed to visualize the differences in the medians of the DTS. RESULTS: Overall mean Ct value increased by 4.4 from the validation to testing after one year at the different storage conditions. Samples heated at 55°C showed a 6.4 Ct difference from validation data. Testing done at six months on 2-8°C stored items showed no statistical difference. At all the remaining testing times and conditions, P-values were less than 0.008 although the absolute mean Ct when compared showed slight increments and accommodated differences for the detection of MTB and rifampicin resistance. Median values for samples stored at 2-8°C were lower compared to those at room temperature. CONCLUSION: DTS stored at 2-8°C remain more stable for one year compared to higher temperatures and can be consistently used as PT materials in more than one PT round for biannual PT providers.


Asunto(s)
Mycobacterium tuberculosis , Configuración de Recursos Limitados , Humanos , Uganda , Ensayos de Aptitud de Laboratorios/métodos , Rifampin , Sensibilidad y Especificidad
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA