Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 20
Filtrar
1.
Phys Rev Lett ; 131(22): 222501, 2023 Dec 01.
Artículo en Inglés | MEDLINE | ID: mdl-38101385

RESUMEN

We report on the results obtained with the global CUPID-0 background model, which combines the data collected in the two measurement campaigns for a total exposure of 8.82 kg×yr of ^{82}Se. We identify with improved precision the background sources within the 3 MeV energy region, where neutrinoless double ß decay of ^{82}Se and ^{100}Mo is expected, making more solid the foundations for the background budget of the next-generation CUPID experiment. Relying on the excellent data reconstruction, we measure the two-neutrino double ß-decay half-life of ^{82}Se with unprecedented accuracy: T_{1/2}^{2ν}=[8.69±0.05(stat)_{-0.06}^{+0.09}(syst)]×10^{19} yr.

2.
Phys Rev Lett ; 129(11): 111801, 2022 Sep 09.
Artículo en Inglés | MEDLINE | ID: mdl-36154394

RESUMEN

CUPID-0, an array of Zn^{82}Se cryogenic calorimeters, was the first medium-scale demonstrator of the scintillating bolometers' technology. The first project phase (March 2017-December 2018) allowed the most stringent limit on the neutrinoless double beta decay half-life of the isotope of interest, ^{82}Se, to be set. After a six month long detector upgrade, CUPID-0 began its second and last phase (June 2019-February 2020). In this Letter, we describe the search for neutrinoless double beta decay of ^{82}Se with a total exposure (phase I+II) of 8.82 kg yr^{-1} of isotope. We set a limit on the half-life of ^{82}Se to the ground state of ^{82}Kr of T_{1/2}^{0ν}(^{82}Se)>4.6×10^{24} yr (90% credible interval), corresponding to an effective Majorana neutrino mass m_{ßß}<(263-545) meV. We also set the most stringent lower limits on the neutrinoless decays of ^{82}Se to the 0_{1}^{+}, 2_{1}^{+}, and 2_{2}^{+} excited states of ^{82}Kr, finding 1.8×10^{23} yr, 3.0×10^{23} yr, and 3.2×10^{23} yr (90% credible interval) respectively.

3.
Phys Rev Lett ; 123(3): 032501, 2019 Jul 19.
Artículo en Inglés | MEDLINE | ID: mdl-31386478

RESUMEN

CUPID-0 is the first pilot experiment of CUPID, a next-generation project for the measurement of neutrinoless double beta decay (0νDBD) with scintillating bolometers. The detector, consisting of 24 enriched and 2 natural ZnSe crystals, has been taking data at Laboratori Nazionali del Gran Sasso from June 2017 to December 2018, collecting a ^{82}Se exposure of 5.29 kg×yr. In this Letter we present the phase-I results in the search for 0νDBD. We demonstrate that the technology implemented by CUPID-0 allows us to reach the lowest background for calorimetric experiments: (3.5_{-0.9}^{+1.0})×10^{-3} counts/(keV kg yr). Monitoring 3.88×10^{25} ^{82}Se nuclei×yr we reach a 90% credible interval median sensitivity of T_{1/2}^{0ν}>5.0×10^{24} yr and set the most stringent limit on the half-life of ^{82}Se 0νDBD: T_{1/2}^{0ν}>3.5×10^{24} yr (90% credible interval), corresponding to m_{ßß}<(311-638) meV depending on the nuclear matrix element calculations.

4.
Phys Rev Lett ; 123(26): 262501, 2019 Dec 31.
Artículo en Inglés | MEDLINE | ID: mdl-31951429

RESUMEN

We report on the measurement of the two-neutrino double-ß decay of ^{82}Se performed for the first time with cryogenic calorimeters, in the framework of the CUPID-0 experiment. With an exposure of 9.95 kg yr of Zn^{82}Se, we determine the two-neutrino double-ß decay half-life of ^{82}Se with an unprecedented precision level, T_{1/2}^{2ν}=[8.60±0.03(stat) _{-0.13}^{+0.19}(syst)]×10^{19} yr. The very high signal-to-background ratio, along with the detailed reconstruction of the background sources allowed us to identify the single state dominance as the underlying mechanism of such a process, demonstrating that the higher state dominance hypothesis is disfavored at the level of 5.5σ.

5.
Phys Rev Lett ; 120(23): 232502, 2018 Jun 08.
Artículo en Inglés | MEDLINE | ID: mdl-29932707

RESUMEN

We report the result of the search for neutrinoless double beta decay of ^{82}Se obtained with CUPID-0, the first large array of scintillating Zn^{82}Se cryogenic calorimeters implementing particle identification. We observe no signal in a 1.83 kg yr ^{82}Se exposure, and we set the most stringent lower limit on the 0νßß ^{82}Se half-life T_{1/2}^{0ν}>2.4×10^{24} yr (90% credible interval), which corresponds to an effective Majorana neutrino mass m_{ßß}<(376-770) meV depending on the nuclear matrix element calculations. The heat-light readout provides a powerful tool for the rejection of α particles and allows us to suppress the background in the region of interest down to (3.6_{-1.4}^{+1.9})×10^{-3} counts/(keV kg yr), an unprecedented level for this technique.

6.
Eur Phys J C Part Fields ; 83(5): 398, 2023.
Artículo en Inglés | MEDLINE | ID: mdl-37188220

RESUMEN

A 510 day long-term measurement of a 45.3 g platinum foil acting as the sample and high voltage contact in an ultra-low-background high purity germanium detector was performed at Laboratori Nazionali del Gran Sasso (Italy). The data was used for a detailed study of double beta decay modes in natural platinum isotopes. Limits are set in the range O(1014-1019) years (90% C.L.) for several double beta decay transitions to excited states confirming, and partially extending existing limits. The highest sensitivity of the measurement, greater than 1019 years, was achieved for the two neutrino and neutrinoless double beta decay modes of the isotope 198Pt. Additionally, novel limits for inelastic dark matter scattering on 195Pt are placed up to mass splittings of approximately 500 keV. We analyze several techniques to extend the sensitivity and propose a few approaches for future medium-scale experiments with platinum-group elements.

7.
Appl Radiat Isot ; 200: 110904, 2023 Oct.
Artículo en Inglés | MEDLINE | ID: mdl-37421746

RESUMEN

LEGEND-200 (Large Enriched Germanium Experiment for Neutrinoless ßß Decay) is a physics experiment at the Gran Sasso National Laboratories (LNGS) in Italy searching for neutrinoless double beta (0υßß) decay of 76Ge using enriched high purity germanium (HPGe) detectors with a total mass of about 200 kg. During the production of germanium crystals, especially during the crystal cutting, a fraction of the enriched germanium remains as metal residues. To reuse these residual materials again for crystal growing, they must be efficiently purified. A special plant was built to purify and convert Ge metal to GeO2. Quadrupole ICP-MS (Q-ICP-MS) and High Resolution ICP-MS (HR-ICP-MS) were used to characterize the starting materials, reaction and final products. The results of the analyses are presented here.

8.
Eur Phys J C Part Fields ; 81(8): 722, 2021.
Artículo en Inglés | MEDLINE | ID: mdl-34720725

RESUMEN

Localization and modeling of radioactive contaminations is a challenge that ultra-low background experiments are constantly facing. These are fundamental steps both to extract scientific results and to further reduce the background of the detectors. Here we present an innovative technique based on the analysis of α - α delayed coincidences in 232 Th and 238 U decay chains, developed to investigate the contaminations of the ZnSe crystals in the CUPID-0 experiment. This method allows to disentangle surface and bulk contaminations of the detectors relying on the different probability to tag delayed coincidences as function of the α decay position.

9.
PLoS One ; 13(8): e0200910, 2018.
Artículo en Inglés | MEDLINE | ID: mdl-30133443

RESUMEN

This paper describes the production and chemical separation of the 163Ho isotope that will be used in several nuclear physics experiments aiming at measuring the neutrino mass as well as the neutron cross section of the 163Ho isotope. For this purpose, several batches of enriched 162Er have been irradiated at the Institut Laue-Langevin high flux reactor to finally produce 6 mg or 100 MBq of the desired 163Ho isotope. A portion of the Er/Ho mixture is then subjected to a sophisticated chemical separation involving ion exchange chromatography to isolate the Ho product from the Er target material. Before irradiation, a thorough analysis of the impurity content was performed and its implication on the produced nuclide inventory will be discussed.


Asunto(s)
Holmio/química , Holmio/aislamiento & purificación , Radioquímica/métodos , Isótopos , Neutrones , Física Nuclear
10.
Eur Phys J C Part Fields ; 78(11): 888, 2018.
Artículo en Inglés | MEDLINE | ID: mdl-30881205

RESUMEN

The CUPID-0 experiment searches for double beta decay using cryogenic calorimeters with double (heat and light) read-out. The detector, consisting of 24 ZnSe crystals 95 % enriched in 82 Se and two natural ZnSe crystals, started data-taking in 2017 at Laboratori Nazionali del Gran Sasso. We present the search for the neutrino-less double beta decay of 82 Se into the 0 1 + , 2 1 + and 2 2 + excited states of 82 Kr with an exposure of 5.74 kg · yr (2.24 × 10 25  emitters · yr). We found no evidence of the decays and set the most stringent limits on the widths of these processes: Γ ( 82 Se → 82 Kr 0 1 + )8.55 × 10 - 24  yr - 1 , Γ ( 82 Se → 82 Kr 2 1 + ) < 6.25 × 10 - 24  yr - 1 , Γ ( 82 Se → 82 Kr 2 2 + )8.25 × 10 - 24  yr - 1 (90 % credible interval).

11.
Eur Phys J C Part Fields ; 78(9): 734, 2018.
Artículo en Inglés | MEDLINE | ID: mdl-30839752

RESUMEN

The suppression of spurious events in the region of interest for neutrinoless double beta decay will play a major role in next generation experiments. The background of detectors based on the technology of cryogenic calorimeters is expected to be dominated by α particles, that could be disentangled from double beta decay signals by exploiting the difference in the emission of the scintillation light. CUPID-0, an array of enriched Zn 82 Se scintillating calorimeters, is the first large mass demonstrator of this technology. The detector started data-taking in 2017 at the Laboratori Nazionali del Gran Sasso with the aim of proving that dual read-out of light and heat allows for an efficient suppression of the α background. In this paper we describe the software tools we developed for the analysis of scintillating calorimeters and we demonstrate that this technology allows to reach an unprecedented background for cryogenic calorimeters.

12.
Eur Phys J C Part Fields ; 78(5): 428, 2018.
Artículo en Inglés | MEDLINE | ID: mdl-30996670

RESUMEN

The CUPID-0 detector hosted at the Laboratori Nazionali del Gran Sasso, Italy, is the first large array of enriched scintillating cryogenic detectors for the investigation of 82 Se neutrinoless double-beta decay ( 0 ν ß ß ). CUPID-0 aims at measuring a background index in the region of interest (RoI) for 0 ν ß ß at the level of 10 - 3  counts/(keV kg years), the lowest value ever measured using cryogenic detectors. CUPID-0 operates an array of Zn 82 Se scintillating bolometers coupled with bolometric light detectors, with a state of the art technology for background suppression and thorough protocols and procedures for the detector preparation and construction. In this paper, the different phases of the detector design and construction will be presented, from the material selection (for the absorber production) to the new and innovative detector structure. The successful construction of the detector lead to promising preliminary detector performance which is discussed here.

13.
Eur Phys J C Part Fields ; 76(7): 364, 2016.
Artículo en Inglés | MEDLINE | ID: mdl-28280442

RESUMEN

The R&D activity performed during the last years proved the potential of ZnSe scintillating bolometers to the search for neutrino-less double beta decay, motivating the realization of the first large-mass experiment based on this technology: CUPID-0. The isotopic enrichment in [Formula: see text]Se, the Zn[Formula: see text]Se crystals growth, as well as the light detectors production have been accomplished, and the experiment is now in construction at Laboratori Nazionali del Gran Sasso (Italy). In this paper we present the results obtained testing the first three Zn[Formula: see text]Se crystals operated as scintillating bolometers, and we prove that their performance in terms of energy resolution, background rejection capability and intrinsic radio-purity complies with the requirements of CUPID-0.

14.
Artículo en Inglés | MEDLINE | ID: mdl-26705394

RESUMEN

The LUCIFER project aims at deploying the first array of enriched scintillating bolometers for the investigation of neutrinoless double-beta decay of [Formula: see text]Se. The matrix which embeds the source is an array of ZnSe crystals, where enriched [Formula: see text]Se is used as decay isotope. The radiopurity of the initial components employed for manufacturing crystals, that can be operated as bolometers, is crucial for achieving a null background level in the region of interest for double-beta decay investigations. In this work, we evaluated the radioactive content in 2.5 kg of 96.3 % enriched [Formula: see text]Se metal, measured with a high-purity germanium detector at the Gran Sasso deep underground laboratory. The limits on internal contaminations of primordial decay chain elements of [Formula: see text]Th, [Formula: see text]U and [Formula: see text]U are respectively: [Formula: see text]61, [Formula: see text]110 and [Formula: see text]74 [Formula: see text]Bq/kg at 90 % C.L. The extremely low-background conditions in which the measurement was carried out and the high radiopurity of the [Formula: see text]Se allowed us to establish the most stringent lower limits on the half-lives of the double-beta decay of [Formula: see text]Se to 0[Formula: see text], 2[Formula: see text] and 2[Formula: see text] excited states of [Formula: see text]Kr of 3.4[Formula: see text]10[Formula: see text], 1.3[Formula: see text]10[Formula: see text] and 1.0[Formula: see text]10[Formula: see text] y, respectively, with a 90 % C.L.

15.
Eur Phys J C Part Fields ; 75(3): 112, 2015.
Artículo en Inglés | MEDLINE | ID: mdl-25995704

RESUMEN

The European Research Council has recently funded HOLMES, a new experiment to directly measure the neutrino mass. HOLMES will perform a calorimetric measurement of the energy released in the decay of [Formula: see text]Ho. The calorimetric measurement eliminates systematic uncertainties arising from the use of external beta sources, as in experiments with beta spectrometers. This measurement was proposed in 1982 by A. De Rujula and M. Lusignoli, but only recently the detector technological progress allowed to design a sensitive experiment. HOLMES will deploy a large array of low temperature microcalorimeters with implanted [Formula: see text]Ho nuclei. The resulting mass sensitivity will be as low as 0.4 eV. HOLMES will be an important step forward in the direct neutrino mass measurement with a calorimetric approach as an alternative to spectrometry. It will also establish the potential of this approach to extend the sensitivity down to 0.1 eV. We outline here the project with its technical challenges and perspectives.

16.
Minerva Stomatol ; 38(1): 37-45, 1989 Jan.
Artículo en Italiano | MEDLINE | ID: mdl-2651870

RESUMEN

In the present work the problems of artifacts introduced in human oral biopsy specimens are discussed. The circumstances that can result in artifacts include: errors by the surgeon or assistant in handling the tissue at the time of biopsy, an improper fixation and faulty tissue processing. Different types of artifacts are described and illustrated and clinical and technical suggestions are given to prevent alterations of normal morphologic and cytologic features that can compromise an accurate diagnosis.


Asunto(s)
Errores Diagnósticos , Técnicas Histológicas , Enfermedades de la Boca/patología , Manejo de Especímenes/métodos , Biopsia , Fijadores , Humanos , Boca/patología
18.
Appl Radiat Isot ; 67(5): 828-32, 2009 May.
Artículo en Inglés | MEDLINE | ID: mdl-19269836

RESUMEN

The main target of this study is the development and the validation of an internal procedure to measure the pg g(-1) levels, of naturally occurring radioisotopes to select ultra low background detector materials. As there are no ultra low-level certified reference materials commercially available, the performance of ICP-MS was compared with the well established ultra low-level gamma-spectroscopy. This work shows also the reliability of very quick ICP-MS semi-quantitative analyses of an environmental matrix such as a geological sample treated according to conventional protocols.


Asunto(s)
Espectrometría de Masas/normas , Radioisótopos/análisis , Espectrometría gamma/normas , Sedimentos Geológicos , Espectrometría de Masas/métodos , Espectrometría gamma/métodos
19.
Radiat Environ Biophys ; 48(2): 189-96, 2009 Apr.
Artículo en Inglés | MEDLINE | ID: mdl-19169701

RESUMEN

Previously we reported that yeast and Chinese hamster V79 cells cultured under reduced levels of background environmental ionizing radiation show enhanced susceptibility to damage caused by acute doses of genotoxic agents. Reduction of environmental radiation dose rate was achieved by setting up an underground laboratory at Laboratori Nazionali del Gran Sasso, central Italy. We now report on the extension of our studies to a human cell line. Human lymphoblastoid TK6 cells were maintained under identical in vitro culture conditions for six continuous months, at different environmental ionizing radiation levels. Compared to "reference" environmental radiation conditions, we found that cells cultured in the underground laboratories were more sensitive to acute exposures to radiation, as measured both at the level of DNA damage and oxidative metabolism. Our results are compatible with the hypothesis that ultra-low dose rate ionizing radiation, i.e. environmental radiation, may act as a conditioning agent in the radiation-induced adaptive response.


Asunto(s)
Linfocitos/efectos de la radiación , Radiación Ionizante , Antioxidantes/metabolismo , Radiación de Fondo , Catalasa/metabolismo , Línea Celular , Proliferación Celular/efectos de la radiación , Daño del ADN , Relación Dosis-Respuesta en la Radiación , Exposición a Riesgos Ambientales , Humanos , Pruebas de Micronúcleos , Radiometría , Rayos X
20.
Radiat Environ Biophys ; 41(3): 217-24, 2002 Sep.
Artículo en Inglés | MEDLINE | ID: mdl-12373331

RESUMEN

We present the results of an experiment aimed at comparing the effects of different background radiation environments on metabolism and responses to gamma-rays and cycloheximide of cultured mammalian cells. Chinese hamster V79 cells were maintained in exponential growth in parallel for up to 9 months at the Istituto Superiore di Sanità (ISS) and at the INFN-Gran Sasso underground Laboratory (LNGS) where exposure due to gamma-rays and to radon was reduced by factors of about 70 and 25, respectively. After 9 months the cells grown at the LNGS (cumulative gamma dose about 30 microGy, average radon concentration around 5 Bq/m(3)), compared to the cells grown at the ISS (cumulative gamma-ray dose about 2 mGy, average radon concentration around 120 Bq/m(3)), exhibited i). a significant increase of the cell density at confluence, ii). a significantly higher capacity to scavenge organic and inorganic hydroperoxides but a reduced scavenging capacity towards superoxide anions and iii). an increase in both the basal hprt mutation frequency and sensitivity to the mutagenic effect of gamma-rays. The cells grown at the LNGS also showed a greater apoptotic sensitivity starting at the third month of culture, that was no longer detected after 9 months. Overall, these data suggest a role of background ionizing radiation in determining an adaptive response, although they cannot be considered conclusive.


Asunto(s)
Radiación de Fondo , Fibroblastos/fisiología , Fibroblastos/efectos de la radiación , Rayos gamma , Contaminación del Aire Interior/análisis , Contaminación Radiactiva del Aire/análisis , Animales , Apoptosis/efectos de la radiación , División Celular/efectos de la radiación , Línea Celular , Supervivencia Celular/efectos de la radiación , Cricetinae , Relación Dosis-Respuesta en la Radiación , Pulmón/fisiología , Pulmón/efectos de la radiación , Mutación/efectos de la radiación , Proteínas Proto-Oncogénicas c-myc/metabolismo , Dosis de Radiación , Reproducibilidad de los Resultados , Sensibilidad y Especificidad , Proteína p53 Supresora de Tumor/metabolismo
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA