Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 50
Filtrar
Más filtros

País/Región como asunto
Tipo del documento
Intervalo de año de publicación
1.
Neuroradiology ; 66(1): 31-42, 2024 Jan.
Artículo en Inglés | MEDLINE | ID: mdl-38047983

RESUMEN

PURPOSE: Artifacts in magnetic resonance imaging (MRI) scans degrade image quality and thus negatively affect the outcome measures of clinical and research scanning. Considering the time-consuming and subjective nature of visual quality control (QC), multiple (semi-)automatic QC algorithms have been developed. This systematic review presents an overview of the available (semi-)automatic QC algorithms and software packages designed for raw, structural T1-weighted (T1w) MRI datasets. The objective of this review was to identify the differences among these algorithms in terms of their features of interest, performance, and benchmarks. METHODS: We queried PubMed, EMBASE (Ovid), and Web of Science databases on the fifth of January 2023, and cross-checked reference lists of retrieved papers. Bias assessment was performed using PROBAST (Prediction model Risk Of Bias ASsessment Tool). RESULTS: A total of 18 distinct algorithms were identified, demonstrating significant variations in methods, features, datasets, and benchmarks. The algorithms were categorized into rule-based, classical machine learning-based, and deep learning-based approaches. Numerous unique features were defined, which can be roughly divided into features capturing entropy, contrast, and normative measures. CONCLUSION: Due to dataset-specific optimization, it is challenging to draw broad conclusions about comparative performance. Additionally, large variations exist in the used datasets and benchmarks, further hindering direct algorithm comparison. The findings emphasize the need for standardization and comparative studies for advancing QC in MR imaging. Efforts should focus on identifying a dataset-independent measure as well as algorithm-independent methods for assessing the relative performance of different approaches.


Asunto(s)
Procesamiento de Imagen Asistido por Computador , Imagen por Resonancia Magnética , Humanos , Procesamiento de Imagen Asistido por Computador/métodos , Imagen por Resonancia Magnética/métodos , Aprendizaje Automático , Algoritmos , Control de Calidad
2.
Gastroenterol Hepatol ; 47(2): 119-129, 2024 Feb.
Artículo en Inglés, Español | MEDLINE | ID: mdl-36870477

RESUMEN

INTRODUCTION AND AIMS: The outcomes of endoscopic submucosal dissection (ESD) in the esophagus have not been assessed in our country. Our primary aim was to analyze the effectiveness and safety of the technique. MATERIAL AND METHODS: Analysis of the prospectively maintained national registry of ESD. We included all superficial esophageal lesions removed by ESD in 17 hospitals (20 endoscopists) between January 2016 and December 2021. Subepithelial lesions were excluded. The primary outcome was curative resection. We conducted a survival analysis and used logistic regression analysis to assess predictors of non-curative resection. RESULTS: A total of 102 ESD were performed on 96 patients. The technical success rate was 100% and the percentage of en-bloc resection was 98%. The percentage of R0 and curative resection was 77.5% (n=79; 95%CI: 68%-84%) and 63.7% (n=65; 95%CI: 54%-72%), respectively. The most frequent histology was Barrett-related neoplasia (n=55 [53.9%]). The main reason for non-curative resection was deep submucosal invasion (n=25). The centers with a lower volume of ESD obtained worse results in terms of curative resection. The rate of perforation, delayed bleeding and post-procedural stenosis were 5%, 5% and 15.7%, respectively. No patient died or required surgery due to an adverse effect. After a median follow-up of 14months, 20patients (20.8%) underwent surgery and/or chemoradiotherapy, and 9 patients died (mortality 9.4%). CONCLUSIONS: In Spain, esophageal ESD is curative in approximately two out of three patients, with an acceptable risk of adverse events.


Asunto(s)
Resección Endoscópica de la Mucosa , Neoplasias Esofágicas , Humanos , Neoplasias Esofágicas/cirugía , Neoplasias Esofágicas/patología , Resección Endoscópica de la Mucosa/efectos adversos , Resección Endoscópica de la Mucosa/métodos , España , Resultado del Tratamiento , Estudios Retrospectivos
3.
Gastrointest Endosc ; 97(5): 941-951.e2, 2023 05.
Artículo en Inglés | MEDLINE | ID: mdl-36572129

RESUMEN

BACKGROUND AND AIMS: Underwater EMR (UEMR) is an alternative procedure to conventional EMR (CEMR) to treat large, nonpedunculated colorectal lesions (LNPCLs). In this multicenter, randomized controlled clinical trial, we aimed to compare the efficacy and safety of UEMR versus CEMR on LNPCLs. METHODS: We conducted a multicenter, randomized controlled clinical trial from February 2018 to February 2020 in 11 hospitals in Spain. A total of 298 patients (311 lesions) were randomized to the UEMR (n = 149) and CEMR (n = 162) groups. The main outcome was the lesion recurrence rate in at least 1 follow-up colonoscopy. Secondary outcomes included technical aspects, en bloc resection rate, R0 resection rates, and adverse events, among others. RESULTS: There were no differences in the overall recurrence rate (9.5% UEMR vs 11.7% CEMR; absolute risk difference, -2.2%; 95% CI, -9.4 to 4.9). However, considering polyp sizes between 20 and 30 mm, the recurrence rate was lower for UEMR (3.4% UEMR vs 13.1% CEMR; absolute risk difference, -9.7%; 95% CI, -19.4 to 0). The R0 resection showed the same tendency, with significant differences favoring UEMR only for polyps between 20 and 30 mm. Overall, UEMR was faster and easier to perform than CEMR. Importantly, the techniques were equally safe. CONCLUSIONS: UEMR is a valid alternative to CEMR for treating LNPCLs and could be considered the first option of treatment for lesions between 20 and 30 mm due to its higher en bloc and R0 resection rates. (Clinical trial registration number: NCT03567746.).


Asunto(s)
Pólipos del Colon , Neoplasias Colorrectales , Resección Endoscópica de la Mucosa , Humanos , Neoplasias Colorrectales/patología , Colonoscopía/métodos , Pólipos del Colon/patología , Agua , Resección Endoscópica de la Mucosa/métodos , Mucosa Intestinal/patología
4.
Dig Endosc ; 34(6): 1176-1184, 2022 Sep.
Artículo en Inglés | MEDLINE | ID: mdl-35189669

RESUMEN

OBJECTIVES: When bowel preparation (BP) is inadequate, international guidelines recommend repeating the colonoscopy within 1 year to avoid missing clinically relevant lesions. We aimed to determine the rate of missed lesions in patients with inadequate BP through a very early repeat colonoscopy with adequate BP. METHODS: Post hoc analysis was conducted using data collected from a prospective multicenter randomized clinical trial including patients with inadequate BP and then repeat colonoscopy. Inadequate BP was defined as the Boston Bowel Preparation Scale (BBPS) score <2 points in any segment. We included patients with any indication for colonoscopy. The adenoma detection rate (ADR), advanced ADR (AADR), and serrated polyp detection rate (SPDR) were calculated for index and repeat colonoscopies. RESULTS: Of the 651 patients with inadequate BP from the original trial, 413 (63.4%) achieved adequate BP on repeat colonoscopy. The median interval between index and repeat colonoscopies was 28 days. On repeat colonoscopy, the ADR was 45.3% (95% confidence interval [CI] 40.5-50.1%), the AADR was 10.9% (95% CI 8.1-14.3%), and the SPDR was 14.3% (95% CI 10.9-17.7%). Cancer was discovered in four patients (1%; 95% CI 0.2-2.5%). A total of 60.2% of all advanced adenoma (AA) were discovered on repeat colonoscopy. A colon segment scored BBPS = 0 had most AA (66.1%) and all four cancers. CONCLUSION: Patients with inadequate BP present a high rate of AAs on repeat colonoscopy. When a colonoscopy has a colon segment score BBPS = 0, we recommend repeating the colonoscopy as soon as possible.


Asunto(s)
Adenoma , Pólipos del Colon , Adenoma/diagnóstico , Catárticos , Pólipos del Colon/diagnóstico , Pólipos del Colon/patología , Colonoscopía , Humanos , Prevalencia , Estudios Prospectivos
5.
Rev Esp Enferm Dig ; 114(11): 660-662, 2022 11.
Artículo en Inglés | MEDLINE | ID: mdl-35170327

RESUMEN

Esophageal fish bone impaction (EFBI) is a common reason for presentation in the emergency department and a frequent indication for urgent esophagogastroduodenoscopy (EGD). Although it is usually effectively diagnosed and treated by EGD, a confirmed diagnosis prior to the endoscopy is rare as blood tests, radiography and direct laryngoscopy are usually normal. We herein report three cases of EFBI. Two patients had been previously discharged without a correct diagnosis. In one case, the patient had a severe complication that required urgent surgery which could have probably been averted with an early diagnosis. Remarkably, a cervical CT scan was key to diagnose the EFBI in one case and a large retroesophageal abscess in another cases, thus guiding their management. Both patients that underwent an urgent EGD had a favorable outcome without the need for hospitalization. Therefore, meticulous anamnesis, adequate imaging and urgent EGD are key to treat patients with EFBI.


Asunto(s)
Cuerpos Extraños , Humanos , Cuerpos Extraños/complicaciones , Cuerpos Extraños/diagnóstico por imagen , Cuerpos Extraños/cirugía , Esófago/cirugía , Endoscopía Gastrointestinal , Servicio de Urgencia en Hospital , Diagnóstico Precoz
6.
Am J Gastroenterol ; 116(2): 311-318, 2021 02 01.
Artículo en Inglés | MEDLINE | ID: mdl-33149001

RESUMEN

INTRODUCTION: Delayed bleeding (DB) is the most common major complication of endoscopic mucosal resection (EMR). Two randomized clinical trials recently demonstrated that clip closure after EMR of large nonpedunculated colorectal polyps (LNPCPs) reduces the risk of DB. We analyzed the cost-effectiveness of this prophylactic measure. METHODS: EMRs of LNCPCPs were consecutively registered in the ongoing prospective multicenter database of the Spanish EMR Group from May 2013 until July 2017. Patients were classified according to the Spanish Endoscopy Society EMR group (GSEED-RE2) DB risk score. Cost-effectiveness analysis was performed for both Spanish and US economic contexts. The average incremental cost-effectiveness ratio (ICER) thresholds were set at 54,000 € or $100,000 per quality-adjusted life year, respectively. RESULTS: We registered 2,263 EMRs in 2,130 patients. Applying their respective DB relative risk reductions after clip closure (51% and 59%), the DB rate decreased from 4.5% to 2.2% in the total cohort and from 13.7% to 5.7% in the high risk of the DB GSEED-RE2 subgroup. The ICERs for the universal clipping strategy in Spain and the United States, 469,706 € and $1,258,641, respectively, were not cost effective. By contrast, selective clipping in the high-risk of DB GSEED-RE2 subgroup was cost saving, with a negative ICER of -2,194 € in the Spanish context and cost effective with an ICER of $87,796 in the United States. DISCUSSION: Clip closure after EMR of large colorectal lesions is cost effective in patients with a high risk of bleeding. The GSEED-RE2 DB risk score may be a useful tool to identify that high-risk population.


Asunto(s)
Neoplasias Colorrectales/cirugía , Resección Endoscópica de la Mucosa/métodos , Pólipos/cirugía , Hemorragia Posoperatoria/prevención & control , Instrumentos Quirúrgicos/economía , Técnicas de Cierre de Heridas/economía , Anciano , Anciano de 80 o más Años , Colonoscopía/economía , Colonoscopía/métodos , Neoplasias Colorrectales/patología , Análisis Costo-Beneficio , Femenino , Humanos , Masculino , Persona de Mediana Edad , Pólipos/patología , Hemorragia Posoperatoria/economía , Hemorragia Posoperatoria/terapia , Años de Vida Ajustados por Calidad de Vida , España , Carga Tumoral
7.
Surg Endosc ; 35(2): 620-625, 2021 02.
Artículo en Inglés | MEDLINE | ID: mdl-32072275

RESUMEN

BACKGROUND: Missed adenomas are the main concern for endoscopists. Right colon retroflexion (RCR) seems to increase the adenoma detection rate (ADR), but important variation in success and usefulness of this maneuver has been reported in the literature AIMS: Primary objective: to assess additional adenoma detection rate (AADR) detected during the RCR attempt. Secondary objectives: to assess success rates of RCR, variables associated with it, and safety of RCR. METHODS: This is a prospective, unicentric, non-randomized study. Consecutive colonoscopies done by six endoscopists (3 of them with < 3 years of experience and 3 with > 3 years) from March to May 2017 were included. Olympus colonoscopes were used (CF-H190, CF-H180) Demographic, clinical, and endoscopic variables were collected. RESULTS: 463 colonoscopies were included. RCR success rate was 93.1% (431/463 colonoscopies). Forty additional lesions were visualized during RCR in 34/463 colonoscopies (7.3%). Additional adenomas were detected in 31/463 colonoscopies (6.7%; OR 0.07). HISTOLOGY: low-grade dysplasia adenomas in 29/40 (72.5%) lesions; 3/40 (7.5%), adenomas with high-grade dysplasia; and 7/40 (17.5%) sessile serrated lesions. Additional adenoma detection contributed to modify the colonoscopy surveillance interval in 25 patients (5.4% of the cohort). Variables associated with RCR success in multivariate analysis were no previous abdominal surgery, length of colonoscope insertion in cecum < 80 cm, and use of Olympus 190 series colonoscopes. No differences between endoscopists' experience were found. RCR was a safe maneuver, with no adverse events in our study. CONCLUSIONS: RCR is a feasible and safe maneuver that can increase ADR, so its routine inclusion in colonoscopy practice should be considered.


Asunto(s)
Adenoma/diagnóstico por imagen , Neoplasias del Colon/diagnóstico por imagen , Colonoscopía/métodos , Adenoma/patología , Adulto , Anciano , Anciano de 80 o más Años , Ciego , Colon/diagnóstico por imagen , Colon/patología , Neoplasias del Colon/patología , Colonoscopios , Colonoscopía/efectos adversos , Colonoscopía/instrumentación , Femenino , Humanos , Masculino , Persona de Mediana Edad , Estudios Prospectivos
8.
Gastroenterology ; 157(5): 1213-1221.e4, 2019 11.
Artículo en Inglés | MEDLINE | ID: mdl-31362007

RESUMEN

BACKGROUND & AIMS: It is not clear whether closure of mucosal defects with clips after colonic endoscopic mucosal resection (EMR) prevents delayed bleeding, although it seems to have no protective effects when risk is low. We performed a randomized trial to evaluate the efficacy of complete clip closure of large (≥2 cm) nonpedunculated colorectal lesions after EMR in patients with an estimated average or high risk of delayed bleeding. METHODS: We performed a single-blind trial at 11 hospitals in Spain from May 2016 through June 2018, including 235 consecutive patients who underwent EMR for large nonpedunculated colorectal lesions with an average or high risk of delayed bleeding (based on Spanish Endoscopy Society Endoscopic Resection Group score). Participants were randomly assigned to groups that received closure of the scar with 11-mm through-the-scope clips (treated, n = 119) or no clip (control, n = 116). The primary outcome was proportion of patients in each group with delayed bleeding, defined as evident hematochezia that required medical intervention within 15 days after colonoscopy. RESULTS: In the clip group, complete closure was achieved in 68 (57%) cases, with partial closure in 33 (28%) cases and failure to close in 18 (15%) cases. Delayed bleeding occurred in 14 (12.1%) patients in the control group and in 6 (5%) patients in the clip group (absolute risk difference, reduction of 7% in the clip group; 95% confidence interval, -14.7% to 0.3%). After completion of the clip closure, there was only 1 (1.5%) case of delayed bleeding (absolute risk difference, reduction of 10.6%; 95% confidence interval, -4.3% to 17.9%). CONCLUSIONS: In a randomized trial of patients with large nonpedunculated colorectal lesions undergoing EMR, we found that clip closure of mucosal defects in patients with a risk of bleeding can be a challenge, but also reduces delayed bleeding. Prevention of delayed bleeding required complete clip closure. ClinicalTrials.gov ID: NCT02765022.


Asunto(s)
Adenocarcinoma/cirugía , Pólipos Adenomatosos/cirugía , Pólipos del Colon/cirugía , Neoplasias Colorrectales/cirugía , Resección Endoscópica de la Mucosa/efectos adversos , Hemorragia Gastrointestinal/prevención & control , Hemostasis Quirúrgica/instrumentación , Hemorragia Posoperatoria/prevención & control , Instrumentos Quirúrgicos , Adenocarcinoma/patología , Pólipos Adenomatosos/patología , Anciano , Anciano de 80 o más Años , Pólipos del Colon/patología , Neoplasias Colorrectales/patología , Diseño de Equipo , Femenino , Hemorragia Gastrointestinal/etiología , Humanos , Masculino , Persona de Mediana Edad , Hemorragia Posoperatoria/etiología , Medición de Riesgo , Factores de Riesgo , Método Simple Ciego , España , Factores de Tiempo , Resultado del Tratamiento
9.
Gastroenterology ; 156(1): 75-87, 2019 01.
Artículo en Inglés | MEDLINE | ID: mdl-30296432

RESUMEN

BACKGROUND & AIMS: T1 colorectal polyps with at least 1 risk factor for metastasis to lymph node should be treated surgically and are considered endoscopically unresectable. Optical analysis, based on the Narrow-Band Imaging International Colorectal Endoscopic (NICE) classification system, is used to identify neoplasias with invasion of the submucosa that require endoscopic treatment. We assessed the accuracy of the NICE classification, along with other morphologic characteristics, in identifying invasive polyps that are endoscopically unresectable (have at least 1 risk factor for metastasis to lymph node). METHODS: We performed a multicenter, prospective study of data collected by 58 endoscopists, from 1634 consecutive patients (examining 2123 lesions) at 17 university and community hospitals in Spain from July 2014 through June 2016. All consecutive lesions >10 mm assessed with narrow-band imaging were included. The primary end point was the accuracy of the NICE classification for identifying lesions with deep invasion, using findings from histology analysis as the reference standard. Conditional inference trees were fitted for the analysis of diagnostic accuracy. RESULTS: Of the 2123 lesions analyzed, 89 (4.2%) had features of deep invasion and 91 (4.3%) were endoscopically unresectable. The NICE classification system identified lesions with deep invasion with 58.4% sensitivity (95% CI, 47.5-68.8), 96.4% specificity (95% CI, 95.5-97.2), a positive-predictive value of 41.6% (95% CI, 32.9-50.8), and a negative-predictive value of 98.1% (95% CI, 97.5-98.7). A conditional inference tree that included all variables found the NICE classification to most accurately identify lesions with deep invasion (P < .001). However, pedunculated morphology (P < .007), ulceration (P = .026), depressed areas (P < .001), or nodular mixed type (P < .001) affected accuracy of identification. Results were comparable for identifying lesions that were endoscopically unresectable. CONCLUSIONS: In an analysis of 2123 colon lesions >10 mm, we found the NICE classification and morphologic features identify those with deep lesions with >96% specificity-even in non-expert hands and without magnification. ClinicalTrials.gov number NCT02328066.


Asunto(s)
Adenocarcinoma/patología , Pólipos Adenomatosos/patología , Pólipos del Colon/patología , Colonoscopía/métodos , Neoplasias Colorrectales/patología , Imagen de Banda Estrecha/métodos , Adenocarcinoma/clasificación , Adenocarcinoma/cirugía , Pólipos Adenomatosos/clasificación , Pólipos Adenomatosos/cirugía , Anciano , Toma de Decisiones Clínicas , Pólipos del Colon/clasificación , Pólipos del Colon/cirugía , Neoplasias Colorrectales/clasificación , Neoplasias Colorrectales/cirugía , Femenino , Humanos , Masculino , Persona de Mediana Edad , Invasividad Neoplásica , Estadificación de Neoplasias , Valor Predictivo de las Pruebas , Estudios Prospectivos , Reproducibilidad de los Resultados , Factores de Riesgo , España , Carga Tumoral
10.
Gastrointest Endosc ; 91(4): 868-878.e3, 2020 04.
Artículo en Inglés | MEDLINE | ID: mdl-31655045

RESUMEN

BACKGROUND AND AIMS: The Endoscopic Resection Group of the Spanish Society of Endoscopy (GSEED-RE) model and the Australian Colonic Endoscopic Resection (ACER) model were proposed to predict delayed bleeding (DB) after EMR of large superficial colorectal lesions, but neither has been validated. We validated and updated these models. METHODS: A multicenter cohort study was performed in patients with nonpedunculated lesions ≥20 mm removed by EMR. We assessed the discrimination and calibration of the GSEED-RE and ACER models. Difficulty performing EMR was subjectively categorized as low, medium, or high. We created a new model, including factors associated with DB in 3 cohort studies. RESULTS: DB occurred in 45 of 1034 EMRs (4.5%); it was associated with proximal location (odds ratio [OR], 2.84; 95% confidence interval [CI], 1.31-6.16), antiplatelet agents (OR, 2.51; 95% CI, .99-6.34) or anticoagulants (OR, 4.54; 95% CI, 2.14-9.63), difficulty of EMR (OR, 3.23; 95% CI, 1.41-7.40), and comorbidity (OR, 2.11; 95% CI, .99-4.47). The GSEED-RE and ACER models did not accurately predict DB. Re-estimation and recalibration yielded acceptable results (GSEED-RE area under the curve [AUC], .64 [95% CI, .54-.74]; ACER AUC, .65 [95% CI, .57-.73]). We used lesion size, proximal location, comorbidity, and antiplatelet or anticoagulant therapy to generate a new model, the GSEED-RE2, which achieved higher AUC values (.69-.73; 95% CI, .59-.80) and exhibited lower susceptibility to changes among datasets. CONCLUSIONS: The updated GSEED-RE and ACER models achieved acceptable prediction levels of DB. The GSEED-RE2 model may achieve better prediction results and could be used to guide the management of patients after validation by other external groups. (Clinical trial registration number: NCT03050333.).


Asunto(s)
Resección Endoscópica de la Mucosa , Australia , Estudios de Cohortes , Colonoscopía , Neoplasias Colorrectales/cirugía , Humanos , Factores de Riesgo
11.
Endoscopy ; 52(11): 1026-1035, 2020 11.
Artículo en Inglés | MEDLINE | ID: mdl-32557475

RESUMEN

BACKGROUND: The most important predictor of unsuccessful bowel preparation is previous failure. For those patients with previous failure, we hypothesized that a nurse-led educational intervention by telephone shortly before the colonoscopy appointment could improve cleansing efficacy. METHODS: We performed a multicenter, endoscopist-blinded, randomized controlled trial. Consecutive outpatients with previous inadequate bowel preparation were enrolled. Both groups received the same standard bowel preparation protocol. The intervention group also received reinforced education by telephone within 48 hours before the colonoscopy. The primary outcome was effective bowel preparation according to the Boston Bowel Preparation Scale. Intention-to-treat (ITT) analysis included all randomized patients. Per-protocol analysis included patients who could be contacted by telephone and the control cases. RESULTS: 657 participants were recruited by 11 Spanish hospitals. In the ITT analysis, there was no significant difference between the intervention and control groups in the rate of successful bowel preparation (77.3 % vs. 72 %; P = 0.12). In the intervention group, 267 patients (82.9 %) were contacted by telephone. Per-protocol analysis revealed significantly improved bowel preparation in the intervention group (83.5 % vs. 72.0 %; P = 0.001). CONCLUSION: Among all patients with previous inadequate bowel preparation, nurse-led telephone education did not result in a significant improvement in bowel cleansing. However, in the 83 % of patients who could be contacted, bowel preparation was substantially improved. Phone education may therefore be a useful tool for improving the quality of bowel preparation in those cases.


Asunto(s)
Colonoscopía , Teléfono , Catárticos , Humanos , Análisis de Intención de Tratar , Polietilenglicoles , Estudios Prospectivos , Método Simple Ciego
12.
Rev Esp Enferm Dig ; 112(4): 309-318, 2020 Apr.
Artículo en Inglés | MEDLINE | ID: mdl-32188259

RESUMEN

The present evidence-based guidelines are focused on the use of device-assisted enteroscopy in the management of small-bowel diseases. A panel of experts selected by the Spanish and Portuguese small-bowel study groups reviewed the available evidence focusing on the main indications of this technique, its role in the management algorithm of each indication, and its diagnostic and therapeutic yield. A set of recommendations was issued accordingly.


Asunto(s)
Endoscopía Capsular , Enfermedades Intestinales , Humanos , Enfermedades Intestinales/diagnóstico por imagen , Enfermedades Intestinales/terapia , Intestino Delgado/diagnóstico por imagen , Portugal
13.
Magn Reson Med ; 82(1): 302-311, 2019 07.
Artículo en Inglés | MEDLINE | ID: mdl-30859628

RESUMEN

PURPOSE: To develop motion-robust, blood-suppressed diffusion-weighted imaging (DWI) of the liver with optimized diffusion encoding waveforms and evaluate the accuracy and reproducibility of quantitative apparent diffusion coefficient (ADC) measurements. METHODS: A novel approach for the design of diffusion weighting waveforms, termed M1-optimized diffusion imaging (MODI), is proposed. MODI includes an echo time-optimized motion-robust diffusion weighting gradient waveform design, with a small nonzero first-moment motion sensitivity (M1) value to enable blood signal suppression. Experiments were performed in eight healthy volunteers and five patient volunteers. In each case, DW images and ADC maps were compared between acquisitions using standard monopolar waveforms, motion moment-nulled (M1-nulled and M1-M2-nulled) waveforms, and the proposed MODI approach. RESULTS: Healthy volunteer experiments using MODI showed no significant ADC bias in the left lobe relative to the right lobe (p < .05) demonstrating robustness to cardiac motion, and no significant ADC bias with respect to monopolar-based ADC measured in the right lobe (p < .05), demonstrating blood signal suppression. In contrast, monopolar-based ADC showed significant bias in the left lobe relative to the right lobe (p < .01) due to its sensitivity to motion, and both M1-nulled and M1-M2-nulled-based ADC showed significant bias (p < .01) due to the lack of blood suppression. Preliminary patient results also suggest MODI may enable improved visualization and quantitative assessment of lesions throughout the entire liver. CONCLUSIONS: This novel method for diffusion gradient waveform design enables DWI of the liver with high robustness to motion and suppression of blood signals, overcoming the limitations of conventional monopolar waveforms and moment-nulled waveforms, respectively.


Asunto(s)
Imagen de Difusión por Resonancia Magnética/métodos , Procesamiento de Imagen Asistido por Computador/métodos , Hígado/diagnóstico por imagen , Algoritmos , Humanos , Neoplasias Hepáticas/diagnóstico por imagen , Movimiento/fisiología
14.
Magn Reson Med ; 81(2): 989-1003, 2019 02.
Artículo en Inglés | MEDLINE | ID: mdl-30394568

RESUMEN

PURPOSE: To present a novel Optimized Diffusion-weighting Gradient waveform Design (ODGD) method for the design of minimum echo time (TE), bulk motion-compensated, and concomitant gradient (CG)-nulling waveforms for diffusion MRI. METHODS: ODGD motion-compensated waveforms were designed for various moment-nullings Mn (n = 0, 1, 2), for a range of b-values, and spatial resolutions, both without (ODGD-Mn ) and with CG-nulling (ODGD-Mn -CG). Phantom and in-vivo (brain and liver) experiments were conducted with various ODGD waveforms to compare motion robustness, signal-to-noise ratio (SNR), and apparent diffusion coefficient (ADC) maps with state-of-the-art waveforms. RESULTS: ODGD-Mn and ODGD-Mn -CG waveforms reduced the TE of state-of-the-art waveforms. This TE reduction resulted in significantly higher SNR (P < 0.05) in both phantom and in-vivo experiments. ODGD-M1 improved the SNR of BIPOLAR (42.8 ± 5.3 vs. 32.9 ± 3.3) in the brain, and ODGD-M2 the SNR of motion-compensated (MOCO) and Convex Optimized Diffusion Encoding-M2 (CODE-M2 ) (12.3 ± 3.6 vs. 9.7 ± 2.9 and 10.2 ± 3.4, respectively) in the liver. Further, ODGD-M2 also showed excellent motion robustness in the liver. ODGD-Mn -CG waveforms reduced the CG-related dephasing effects of non CG-nulling waveforms in phantom and in-vivo experiments, resulting in accurate ADC maps. CONCLUSIONS: ODGD waveforms enable motion-robust diffusion MRI with reduced TEs, increased SNR, and reduced ADC bias compared to state-of-the-art waveforms in theoretical results, simulations, phantoms and in-vivo experiments.


Asunto(s)
Imagen de Difusión por Resonancia Magnética , Imagen Eco-Planar , Movimiento (Física) , Fantasmas de Imagen , Acetona , Algoritmos , Encéfalo/diagnóstico por imagen , Pruebas Diagnósticas de Rutina , Humanos , Procesamiento de Imagen Asistido por Computador/métodos , Hígado/diagnóstico por imagen , Relación Señal-Ruido
15.
Gastrointest Endosc ; 90(4): 581-590.e6, 2019 10.
Artículo en Inglés | MEDLINE | ID: mdl-31220444

RESUMEN

BACKGROUND AND AIMS: TC-325 (Hemospray, Cook Medical, Winston-Salem, NC) is an inorganic hemostatic powder recently approved by the U.S. Food and Drug Administration. This study aimed to examine the effectiveness, safety, and predictors of TC-325 failure in a large real-life cohort. METHODS: This was a retrospective study conducted at 21 Spanish centers. All patients treated with TC-325 until September 2018 were included. The primary outcome was treatment failure, defined as failed intraprocedural hemostasis or recurrent bleeding within the first 30 postprocedural days. Secondary outcomes included safety and survival. Risk and predictors of failure were assessed via competing-risk models. RESULTS: The cohort comprised 261 patients, of whom 219 (83.9%) presented with upper gastrointestinal bleeding (GIB). The most common causes were peptic ulcer (28%), malignancy (18.4%), and therapeutic endoscopy-related GIB (17.6%). TC-325 was used as rescue therapy in 191 (73.2%) patients. The rate of intraprocedural hemostasis was 93.5% (95% confidence interval [CI], 90%-96%). Risks of TC-325 failure at postprocedural days 3, 7, and 30 were 21.1%, 24.6%, and 27.4%, respectively. On multivariate analysis, spurting bleeding (P = .004), use of vasoactive drugs (P = .02), and hypotension (P = .008) were independent predictors of failure. Overall 30-day survival was 81.9% (95% CI, 76%-86%) and intraprocedural hemostasis was associated with a better prognosis (adjusted hazard ratio, 0.29; P = .006). Two severe adverse events were noted. CONCLUSION: TC-325 was safe and effective for intraprocedural hemostasis in more than 90% of patients, regardless of the cause or site of bleeding and its use as rescue therapy. In this high-risk cohort treated with TC-325, the 30-day failure rate exceeded 25% and was highest with spurting bleeding or hemodynamic instability.


Asunto(s)
Hemorragia Gastrointestinal/tratamiento farmacológico , Hemostáticos/uso terapéutico , Minerales/uso terapéutico , Hemorragia Posoperatoria/tratamiento farmacológico , Anciano , Anciano de 80 o más Años , Endoscopía Gastrointestinal , Femenino , Hemorragia Gastrointestinal/etiología , Neoplasias Gastrointestinales/complicaciones , Hemostasis Endoscópica , Humanos , Masculino , Persona de Mediana Edad , Úlcera Péptica Hemorrágica/tratamiento farmacológico , Recurrencia , Estudios Retrospectivos , Insuficiencia del Tratamiento
16.
Rev Esp Enferm Dig ; 111(12): 931-934, 2019 Dec.
Artículo en Inglés | MEDLINE | ID: mdl-31696724

RESUMEN

BACKGROUND: post-sphyncterotomy endoscopic retrograde cholangiopancreatography (ERCP) bleeding is an adverse event with an estimated incidence rate of 1.34%. There is no established consensus about how to treat this particular type of gastrointestinal bleed. Placement of fully covered self-expandable biliary metal stents (FCSEBMS) has been evaluated as an alternative treatment with positive outcomes and a low complication rate. AIM: to report the results of a cohort of patients with post-sphyncterotomy bleeding treated in a tertiary care referral hospital with FCSEBMS. METHODS: a retrospective cases series study was performed including all post-ERCP bleeds treated with FCSEBMS (immediate or delayed) from January 2015 to June 2017. Clinical data, laboratory results and endoscopic reports were collected in order to evaluate the rebleeding rate after endoscopic treatment. Two different scenarios were considered: a) prophylactic stent placement after effective endoscopic treatment; and b) stents placed for the treatment of an active postsphyncterotomy bleed, refractory to standard endoscopic therapy. RESULTS: twenty-two patients (14 male, eight women) diagnosed with postsphyncterotomy bleeding were treated with FCSEBMS placement. The stents were placed prophylactically in 15 patients, while the stents were placed as a treatment for a refractory bleed in seven patients. No differences were found between both groups except for a higher anticoagulation rate in the treatment group. Clinical success was achieved in all but one patient, with no complications in relation to stent placement. Distal migration was described in two of the 22 patients included in the study. CONCLUSIONS: temporary placement of FCSEBMS seems to be a technically feasible treatment option for post-ERCP bleeding with a high clinical success rate. The complication rate was low, although randomized studies are needed.


Asunto(s)
Colangiopancreatografia Retrógrada Endoscópica/efectos adversos , Hemorragia Posoperatoria/terapia , Stents Metálicos Autoexpandibles , Esfinterotomía Endoscópica/efectos adversos , Anciano , Anticoagulantes/uso terapéutico , Femenino , Humanos , Masculino , Hemorragia Posoperatoria/etiología , Hemorragia Posoperatoria/prevención & control , Estudios Retrospectivos , Stents Metálicos Autoexpandibles/efectos adversos , Stents Metálicos Autoexpandibles/estadística & datos numéricos , Esfinterotomía Endoscópica/métodos , Resultado del Tratamiento
17.
Rev Esp Enferm Dig ; 110(3): 179-194, 2018 Mar.
Artículo en Inglés | MEDLINE | ID: mdl-29421912

RESUMEN

This document summarizes the contents of the Clinical Guidelines for the Endoscopic Mucosal Resection of Non-Pedunculated Colorectal Lesions that was developed by the working group of the Spanish Society of Digestive Endoscopy (GSEED of Endoscopic Resection). This document presents recommendations for the endoscopic management of superficial colorectal neoplastic lesions.


Asunto(s)
Neoplasias Colorrectales/cirugía , Cirugía Colorrectal/métodos , Resección Endoscópica de la Mucosa/métodos , Endoscopía Gastrointestinal/métodos , Mucosa Intestinal/cirugía , Enfermedades del Colon/cirugía , Cirugía Colorrectal/normas , Resección Endoscópica de la Mucosa/normas , Endoscopía Gastrointestinal/normas , Humanos , Enfermedades del Recto/cirugía
18.
Gastroenterol Hepatol ; 41(3): 175-190, 2018 Mar.
Artículo en Inglés, Español | MEDLINE | ID: mdl-29449039

RESUMEN

This document summarizes the contents of the Clinical Guidelines for the Endoscopic Mucosal Resection of Non-Pedunculated Colorectal Lesions that was developed by the working group of the Spanish Society of Digestive Endoscopy (GSEED of Endoscopic Resection). This document presents recommendations for the endoscopic management of superficial colorectal neoplastic lesions.


Asunto(s)
Neoplasias Colorrectales/cirugía , Resección Endoscópica de la Mucosa/normas , Humanos
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA