Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 93
Filtrar
Más filtros

Bases de datos
País/Región como asunto
Tipo del documento
País de afiliación
Intervalo de año de publicación
1.
Eur J Clin Invest ; 53(10): e14060, 2023 Oct.
Artículo en Inglés | MEDLINE | ID: mdl-37409393

RESUMEN

BACKGROUND: Cancer is a well-known risk factor for venous thromboembolism (VTE). A combined strategy of D-dimer testing and clinical pre-test probability is usually used to exclude VTE. However, its effectiveness is diminished in cancer patients due to reduced specificity, ultimately leading to a decreased clinical utility. This review article seeks to provide a comprehensive summary of how to interpret D-dimer testing in cancer patients. METHODS: In accordance with PRISMA standards, literature pertaining to the diagnostic and prognostic significance of D-dimer testing in cancer patients was carefully chosen from reputable sources such as PubMed and the Cochrane databases. RESULTS: D-dimers have not only a diagnostic value in ruling out VTE but can also serve as an aid for rule-in if their values exceed 10-times the upper limit of normal. This threshold allows a diagnosis of VTE in cancer patients with a positive predictive value of more than 80%. Moreover, elevated D-dimers carry important prognostic information and are associated with VTE reoccurrence. A gradual increase in risk for all-cause death suggests that VTE is also an indicator of biologically more aggressive cancer types and advanced cancer stages. Considering the lack of standardization for D-dimer assays, it is essential for clinicians to carefully consider the variations in assay performance and the specific test characteristics of their institution. CONCLUSIONS: Standardizing D-dimer assays and developing modified pretest probability models specifically for cancer patients, along with adjusted cut-off values for D-dimer testing, could significantly enhance the accuracy and effectiveness of VTE diagnosis in this population.


Asunto(s)
Productos de Degradación de Fibrina-Fibrinógeno , Neoplasias , Humanos , Neoplasias/sangre , Neoplasias/complicaciones , Neoplasias/diagnóstico , Valor Predictivo de las Pruebas , Factores de Riesgo , Tromboembolia Venosa/sangre , Tromboembolia Venosa/diagnóstico , Tromboembolia Venosa/prevención & control , Bioensayo/normas , Sensibilidad y Especificidad
2.
Int J Hyperthermia ; 40(1): 2200582, 2023.
Artículo en Inglés | MEDLINE | ID: mdl-37121606

RESUMEN

The purpose of the study is to retrospectively evaluate the development and technological progress in local oncological treatments of patients with breast cancer liver metastasis (BCLM) using LITT (laser interstitial thermotherapy), MWA (microwave ablation) and TACE (transarterial chemoembolization) ablation techniques in a multimodal application. The study uses data generated between 1993 and 2020. Therapy results were evaluated using the Kaplan-Meier survival estimate, Cox proportional hazard regression and log-rank test. Cox regression analysis showed that the different treatment methods are statistically significant predictors of survival of patients. Median survival times for groups treated with LITT (212 patients) and LITT + TACE (215 patients) were 2.2 years and 2.1 years respectively; median survival times for groups treated with MWA (17 patients) and MWA + TACE (143 patients) were 5.6 and 2.4 years respectively. For LITT only treatments, the 1-, 3- and 5-year survival probability scored 80%, 37%, 22%. Results for combined LITT + TACE treatments were 76%, 34% and 15%. In group MWA, the 1-/3-/5-year survival probability rates were calculated as 89%, 89%, 89% (however, they should be interpreted carefully due to a relatively small sample size of n = 17 patients). Group MWA + TACE offered values of 77%, 38% and 22%. A separate group of 549 patients was analyzed with TACE monotherapy treatment. The estimated median survival time in this group was 0.8 years. The 1-/3-/5-year survival probability rates were 37%, 8% and 4%. Treatments with combined MWA and MWA + TACE resulted in the best median survival time estimations in this study.


Asunto(s)
Neoplasias de la Mama , Carcinoma Hepatocelular , Quimioembolización Terapéutica , Neoplasias Hepáticas , Humanos , Femenino , Neoplasias Hepáticas/patología , Carcinoma Hepatocelular/cirugía , Neoplasias de la Mama/terapia , Estudios Retrospectivos , Quimioembolización Terapéutica/métodos , Terapia Combinada , Resultado del Tratamiento , Melanoma Cutáneo Maligno
3.
Eur Radiol ; 32(5): 3288-3296, 2022 May.
Artículo en Inglés | MEDLINE | ID: mdl-34797384

RESUMEN

OBJECTIVE: To determine the early treatment response after microwave ablation (MWA) of inoperable lung neoplasms using the apparent diffusion coefficient (ADC) value calculated 24 h after the ablation. MATERIALS AND METHODS: This retrospective study included 47 patients with 68 lung lesions, who underwent percutaneous MWA from January 2008 to December 2017. Evaluation of the lesions was done using MRI including DWI sequence with ADC value calculation pre-ablation and 24 h post-ablation. DWI-MR was performed with b values (50, 400, 800 mm2/s). The post-ablation follow-up was performed using chest CT and/or MRI within 24 h following the procedure; after 3, 6, 9, and 12 months; and every 6 months onwards to determine the local tumor response. The post-ablation ADC value changes were compared to the end response of the lesions. RESULTS: Forty-seven patients (mean age: 63.8 ± 14.2 years, 25 women) with 68 lesions having a mean tumor size of 1.5 ± 0.9 cm (range: 0.7-5 cm) were evaluated. Sixty-one lesions (89.7%) showed a complete treatment response, and the remaining 7 lesions (10.3%) showed a local progression (residual activity). There was a statistically significant difference regarding the ADC value measured 24 h after the ablation between the responding (1.7 ± 0.3 × 10-3 mm2/s) and non-responding groups (1.4 ± 0.3 × 10-3 mm2/s) with significantly higher values in the responding group (p = 0.001). A suggested ADC cut-off value of 1.42 could be used as a reference point for the post-ablation response prediction (sensitivity: 66.67%, specificity: 84.21%, PPV: 66.7%, and NPV: 84.2%). No significant difference was reported regarding the ADC value performed before the ablation as a factor for the prognosis of treatment response (p = 0.86). CONCLUSION: ADC value assessment following ablation may allow the early prediction of treatment efficacy after MWA of inoperable lung neoplasms. KEY POINTS: • ADC value calculated 24 h post-treatment may allow the early prediction of MWA efficacy as a treatment of pulmonary tumors and can be used in the early immediate post-ablation imaging follow-up. • The pre-treatment ADC value of lung neoplasms is not different between the responding and non-responding tumors.


Asunto(s)
Neoplasias Pulmonares , Microondas , Anciano , Imagen de Difusión por Resonancia Magnética/métodos , Estudios de Factibilidad , Femenino , Humanos , Neoplasias Pulmonares/diagnóstico por imagen , Neoplasias Pulmonares/cirugía , Imagen por Resonancia Magnética , Masculino , Microondas/uso terapéutico , Persona de Mediana Edad , Estudios Retrospectivos , Tomografía Computarizada por Rayos X
4.
Eur Radiol ; 32(1): 234-242, 2022 Jan.
Artículo en Inglés | MEDLINE | ID: mdl-34226991

RESUMEN

OBJECTIVES: To correlate the radiological assessment of the mastoid facial canal in postoperative cochlear implant (CI) cone-beam CT (CBCT) and other possible contributing clinical or implant-related factors with postoperative facial nerve stimulation (FNS) occurrence. METHODS: Two experienced radiologists evaluated retrospectively 215 postoperative post-CI CBCT examinations. The mastoid facial canal diameter, wall thickness, distance between the electrode cable and mastoid facial canal, and facial-chorda tympani angle were assessed. Additionally, the intracochlear position and the insertion angle and depth of electrodes were evaluated. Clinical data were analyzed for postoperative FNS within 1.5-year follow-up, CI type, onset, and causes for hearing loss such as otosclerosis, meningitis, and history of previous ear surgeries. Postoperative FNS was correlated with the measurements and clinical data using logistic regression. RESULTS: Within the study population (mean age: 56 ± 18 years), ten patients presented with FNS. The correlations between FNS and facial canal diameter (p = 0.09), wall thickness (p = 0.27), distance to CI cable (p = 0.44), and angle with chorda tympani (p = 0.75) were statistically non-significant. There were statistical significances for previous history of meningitis/encephalitis (p = 0.001), extracochlear-electrode-contacts (p = 0.002), scala-vestibuli position (p = 0.02), younger patients' age (p = 0.03), lateral-wall-electrode type (p = 0.04), and early/childhood onset hearing loss (p = 0.04). Histories of meningitis/encephalitis and extracochlear-electrode-contacts were included in the first two steps of the multivariate logistic regression. CONCLUSION: The mastoid-facial canal radiological assessment and the positional relationship with the CI electrode provide no predictor of postoperative FNS. Histories of meningitis/encephalitis and extracochlear-electrode-contacts are important risk factors. KEY POINTS: • Post-operative radiological assessment of the mastoid facial canal and the positional relationship with the CI electrode provide no predictor of post-cochlear implant facial nerve stimulation. • Radiological detection of extracochlear electrode contacts and the previous clinical history of meningitis/encephalitis are two important risk factors for postoperative facial nerve stimulation in cochlear implant patients. • The presence of scala vestibuli electrode insertion as well as the lateral wall electrode type, the younger patient's age, and early onset of SNHL can play important role in the prediction of post-cochlear implant facial nerve stimulation.


Asunto(s)
Implantación Coclear , Implantes Cocleares , Adulto , Anciano , Niño , Cóclea , Nervio Facial/diagnóstico por imagen , Humanos , Apófisis Mastoides/diagnóstico por imagen , Apófisis Mastoides/cirugía , Persona de Mediana Edad , Estudios Retrospectivos
5.
Int J Hyperthermia ; 39(1): 788-795, 2022.
Artículo en Inglés | MEDLINE | ID: mdl-35658772

RESUMEN

PURPOSE: To evaluate the overall survival (OS), local progression-free survival (PFS) and prognostic factors of patients with colorectal cancer liver metastases (CRLM) undergoing microwave ablation (MWA). METHOD: A total of 132 patients were retrospectively enrolled who had been treated between 2010 and 2018. For the evaluation of survival rates, all patients were divided according to their indications (curative n = 57 and debulking (patients with additional non-target extrahepatic metastases) n = 75). In total, 257 ablations were evaluated for prognostic factors: number of liver metastases, primary tumor origin (PTO), diameter and volume of metastases, duration and energy of ablation. RESULTS: The OS was 32.1 months with 93.2% of patients free from recurrence at 28.3 months (median follow-up time). The one- year and three-year OS were 82.72% and 41.66%, respectively. The OS and recurrence-free survival of the curative group were statistically significantly higher than the debulking group (p < .001). Statistically significant prognostic factors for OS included the location of the primary tumor (p < .038) and the number of metastases (all p < .017). Metastasis diameter and volume and ablation duration and energy had no significant correlation with survival (p > .05). CONCLUSIONS: Satisfactory OS and local tumor PFS can be achieved in patients with CRLM using MWA with the number of metastases and the location of the primary tumor influencing the outcome of patients. The metastasis's size and the duration and energy used for ablation were not of significant prognostic value.


Asunto(s)
Ablación por Catéter , Neoplasias Colorrectales , Neoplasias Hepáticas , Neoplasias Colorrectales/patología , Humanos , Neoplasias Hepáticas/secundario , Neoplasias Hepáticas/cirugía , Microondas/uso terapéutico , Estudios Retrospectivos , Resultado del Tratamiento
6.
Eur Radiol ; 29(7): 3390-3400, 2019 Jul.
Artículo en Inglés | MEDLINE | ID: mdl-31016441

RESUMEN

OBJECTIVE: Percutaneous biliary interventions (PBIs) can be associated with a high patient radiation dose, which can be reduced when national diagnostic reference levels (DRLs) are kept in mind. The aim of this multicentre study was to investigate patient radiation exposure in different percutaneous biliary interventions, in order to recommend national DRLs. METHODS: A questionnaire asking for the dose area product (DAP) and the fluoroscopy time (FT) in different PBIs with ultrasound- or fluoroscopy-guided bile duct punctures was sent to 200 advanced care hospitals. Recommended national DRLs are set at the 75th percentile of all DAPs. RESULTS: Twenty-three facilities (9 interventional radiology depts. and 14 gastroenterology depts.) returned the questionnaire (12%). Five hundred sixty-five PBIs with 19 different interventions were included in the analysis. DAPs (range 4-21,510 cGy·cm2) and FTs (range 0.07-180.33 min) varied substantially depending on the centre and type of PBI. The DAPs of initial PBIs were significantly (p < 0.0001) higher (median 2162 cGy·cm2) than those of follow-up PBIs (median 464 cGy·cm2). There was no significant difference between initial PBIs with ultrasound-guided bile duct puncture (2162 cGy·cm2) and initial PBIs with fluoroscopy-guided bile duct puncture (2132 cGy·cm2) (p = 0.85). FT varied substantially (0.07-180.33 min). CONCLUSIONS: DAPs and FTs in percutaneous biliary interventions showed substantial variations depending on the centre and the type of PBI. PBI with US-guided bile duct puncture did not reduce DAP, when compared to PBI with fluoroscopy-guided bile duct puncture. National DRLs of 4300 cGy·cm2 for initial PBIs and 1400 cGy·cm2 for follow-up PBIs are recommended. KEY POINTS: • DAPs and FTs in percutaneous biliary interventions showed substantial variations depending on the centre and the type of PBI. • PBI with US-guided bile duct puncture did not reduce DAP when compared to PBI with fluoroscopy-guided bile duct puncture. • DRLs of 4300 cGy·cm2for initial PBIs (establishing a transhepatic tract) and 1400 cGy·cm2for follow-up PBIs (transhepatic tract already established) are recommended.


Asunto(s)
Sistema Biliar/diagnóstico por imagen , Dosis de Radiación , Exposición a la Radiación/estadística & datos numéricos , Radiología Intervencionista/estadística & datos numéricos , Adulto , Procedimientos Quirúrgicos del Sistema Biliar/métodos , Femenino , Fluoroscopía/estadística & datos numéricos , Alemania , Humanos , Masculino , Radiografía Intervencional/estadística & datos numéricos , Radiología Intervencionista/normas , Valores de Referencia , Estudios Retrospectivos , Stents
7.
AJR Am J Roentgenol ; 213(6): 1388-1396, 2019 12.
Artículo en Inglés | MEDLINE | ID: mdl-31593520

RESUMEN

OBJECTIVE. The objective of our study was to evaluate the clinical performance of a new high-frequency (HF) microwave ablation (MWA) technology with spatial energy control for treatment of lung malignancies in comparison with a conventional low-frequency (LF) MWA technology. MATERIALS AND METHODS. In this retrospective study, 59 consecutive patients (mean age, 58.9 ± 12.6 [SD] years) were treated in 71 sessions using HF spatial-energy-control MWA. Parameters collected were technical success and efficacy, tumor diameter, tumor and ablation volumes, ablation time, output energy, complication rate, 90-day mortality, local tumor progression (LTP), ablative margin size, and ablation zone sphericity. Results were compared with the same parameters retrospectively collected from the last 71 conventional LF-MWA sessions. This group consisted of 56 patients (mean age, 60.3 ± 10.8 years). Statistical comparisons were performed using the Wilcoxon-Mann-Whitney test. RESULTS. Technical success was 98.6% for both technologies; technical efficacy was 97.2% for HF spatial-energy-control MWA and 95.8% for LF-MWA. The 90-day mortality rate was 5.1% (3/59) in the HF spatial-energy-control MWA group and 5.4% (3/56) in the LF-MWA group; for both groups, there were zero intraprocedural deaths. The median ablation time was 8.0 minutes for HF spatial-energy-control MWA and 10.0 minutes for LF-MWA (p < 0.0001). Complications were recorded in 21.1% (15/71) of HF spatial-energy-control MWA sessions and in 31.0% (22/71) of LF-MWA sessions (p = 0.182); of these complications, 4.2% (3/71) were major complications in the HF spatial-energy-control MWA group, and 9.9% (7/71) were major complications in the LF-MWA group. The median deviation from ideal sphericity (1.0) was 0.195 in the HF spatial-energy-control MWA group versus 0.376 in the LF-MWA group (p < 0.0001). Absolute minimal ablative margins per ablation were 7.5 ± 3.6 mm (mean ± SD) in the HF spatial-energy-control MWA group versus 4.2 ± 3.0 mm in the LF-MWA group (p < 0.0001). In the HF spatial-energy-control MWA group, LTP at 12 months was 6.5% (4/62). LTP at 12 months in the LF-MWA group was 12.5% (7/56). Differences in LTP rate (p = 0.137) and time point (p = 0.833) were not significant. CONCLUSION. HF spatial-energy-control MWA technology and conventional LFMWA technology are safe and effective for the treatment of lung malignancies independent of the MWA system used. However, HF spatial-energy-control MWA as an HF and high-energy MWA technique achieves ablation zones that are closer to an ideal sphere and achieves larger ablative margins than LF-MWA (p < 0.0001).


Asunto(s)
Técnicas de Ablación/métodos , Neoplasias Pulmonares/diagnóstico por imagen , Neoplasias Pulmonares/cirugía , Microondas/uso terapéutico , Complicaciones Posoperatorias/diagnóstico por imagen , Tomografía Computarizada por Rayos X , Medios de Contraste , Progresión de la Enfermedad , Femenino , Humanos , Yopamidol/análogos & derivados , Masculino , Persona de Mediana Edad , Recurrencia Local de Neoplasia/diagnóstico por imagen , Estudios Retrospectivos
8.
Pancreatology ; 18(1): 94-99, 2018 Jan.
Artículo en Inglés | MEDLINE | ID: mdl-29221632

RESUMEN

PURPOSE: To retrospectively investigate the effectiveness of triple drug combination transarterial chemoembolization (TACE) on local tumor response and survival in patients with liver metastases from pancreatic cancer. Also, this study will evaluate the variances in response regarding the number of metastases, assess the correlation between tumor response and the changes in the apparent diffusion coefficients (ADC) in diffusion weighted (DW) MRI. MATERIALS AND METHODS: One hundred and twelve patients (58 men and 54 women; mean age 57) with malignant liver metastases from pancreatic adenocarcinoma underwent at least one session of TACE with a chemotherapeutic combination of mitomycin C, cisplatin, and gemcitabine. A size-based evaluation of tumor response (response evaluation criteria in solid tumors (RECIST)) was conducted, along with ADC values, and survival indices as related to treatment pattern. RESULTS: Four weeks following the end of the treatment, 78.26% of patients showed stable disease and 11.59% showed partial response. The median survival time was 19 months and for the stable disease group, 26 months. Low pretreatment ADC values showed no significant correlation to poor response to treatment (r = 0.347,p = 0.146). CONCLUSION: The triple drug TACE technique showed improvements in median survival times in patients with hepatic metastases from pancreatic carcinoma and helped control disease progression, whereas the number of hepatic lesions was not a statistically significant factor in patients' response to TACE. The data suggest that pre-treatment ADC values in DW-MRI have no statistical correlation with tumor response.


Asunto(s)
Adenocarcinoma/patología , Quimioembolización Terapéutica , Neoplasias Hepáticas/secundario , Neoplasias Pancreáticas/patología , Adenocarcinoma/diagnóstico por imagen , Adenocarcinoma/terapia , Adulto , Anciano , Anciano de 80 o más Años , Femenino , Humanos , Neoplasias Hepáticas/diagnóstico por imagen , Neoplasias Hepáticas/terapia , Imagen por Resonancia Magnética , Masculino , Persona de Mediana Edad , Neoplasias Pancreáticas/terapia
9.
Int J Colorectal Dis ; 33(7): 973-977, 2018 Jul.
Artículo en Inglés | MEDLINE | ID: mdl-29523989

RESUMEN

PURPOSE: The incidence of incisional hernia (IH) at ileostomy closure site has not been sufficiently evaluated. Temporary loop ileostomy is routinely used in patients after low anterior resection for rectal cancer. The goal of this study was to compare the IH rates of standard suture skin closure and purse-string skin closure techniques. PATIENTS AND METHODS: Patients undergoing ileostomy reversal and follow-up CT scan at the University Hospital Frankfurt between January 2009 and December 2015 were retrospectively analyzed regarding IH and associated risk factors. Patients received either direct stitch skin closure (group DC) or purse-string skin closure (group PS). RESULTS: In total, 111 patients underwent ileostomy reversal in the aforementioned period. In 88 patients, a CT scan was performed 12-24 months after ileostomy reversal for cancer follow-up. Median follow-up was 12 months. Median time interval between ileostoma formation and closure was 12 (± 4 SD) weeks. In 19 of 88 patients (21.5%), an IH was detected. The incidence of IH detected by CT scan was significantly lower in the PS group (n = 7, 12.9%) compared to the DC group (n = 12, 35.2%, p = 0.017). CONCLUSIONS: This retrospective study shows an advantage of the purse-string skin closure technique in ileostomy reversals. The use of this technique for skin closure following ileostomy reversals is recommended to reduce the IH rates. Randomized controlled trials are needed to confirm these findings.


Asunto(s)
Ileostomía/efectos adversos , Hernia Incisional/etiología , Alemania , Humanos , Incidencia , Estudios Retrospectivos , Infección de la Herida Quirúrgica
10.
Int J Hyperthermia ; 34(6): 883-890, 2018 09.
Artículo en Inglés | MEDLINE | ID: mdl-28877612

RESUMEN

PURPOSE: To retrospectively investigate the role of a contrast enhanced MRI (ceMRI) performed 24 h after a microwave ablation (MWA) of the lung, in predicting local tumour progression (LTP) and detecting complications compared to an unenhanced CT. MATERIAL AND METHODS: Forty-nine patients who underwent MWA of 77 lung metastases between 2008 and 2015 were included. All patients received an unenhanced chest CT and a ceMRI (including T2 and ceT1) 24 h after MWA. The conspicuities of the peripheral rim and the ablated tumour were scored using 1-3 scales and compared between examinations. The safety margin was measured directly (both scores ≥2) and indirectly using a subtraction method. The ability of each imaging modality to predict LTP based on safety margin width was analysed using receiver operating characteristic curves. The MRI ability to detect a pneumothorax was compared to CT. RESULTS: The peripheral rim was best visualised on T2 followed by T1 and CT. The tumour was best visualised on CT, followed by T1 and T2. Direct safety margin measurement was possible on CT, ceT1 and T2 in 68.8%, 64.9% and 27.3% of cases, respectively. Direct CT (AUC = 0.77) and ceT1 (AUC = 0.76) measurements had better diagnostic performance than indirect CT (AUC = 0.72), ceT1 (AUC = 0.70) and T2 (AUC = 0.69) measurements. The MRI sensitivity and specificity for pneumothorax were 60.8% and 87.0%, respectively. Only one pneumothorax >1 cm was missed. CONCLUSIONS: A ceMRI performed 24 h after MWA of lung tumours has a similar ability to predict LTP and detect important complications as a CT has.


Asunto(s)
Ablación por Catéter/métodos , Neoplasias Pulmonares/diagnóstico por imagen , Imagen por Resonancia Magnética/métodos , Microondas/uso terapéutico , Femenino , Humanos , Neoplasias Pulmonares/patología , Neoplasias Pulmonares/cirugía , Masculino , Estudios Retrospectivos
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA