Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 6 de 6
Filtrar
1.
Cancers (Basel) ; 12(9)2020 Sep 03.
Artículo en Inglés | MEDLINE | ID: mdl-32899426

RESUMEN

Cancer cell lines allow the identification of clinically relevant alterations and the prediction of drug response. However, sequencing data for hepatobiliary cancer cell lines in general, and particularly gallbladder cancer (GBC), are sparse. Here, we apply RNA sequencing to characterize 10 GBC, eight hepatocellular carcinoma, and five cholangiocarcinoma (CCA) cell lines. RNA extraction, quality control, library preparation, sequencing, and pre-processing of sequencing data were implemented using state-of-the-art techniques. Public data from the MSK-IMPACT database and a large cohort of Japanese biliary tract cancer patients were used to illustrate the usage of the released data. The total number of exonic mutations varied from 7207 for the cell line NOZ to 9760 for HuCCT1. Researchers planning experiments that require TP53 mutations could use the cell lines NOZ, OCUG-1, SNU308, or YoMi. Mz-Cha-1 showed mutations in ATM, SNU308 presented SMAD4 mutations, and the only investigated cell line that showed ARID1A mutations was GB-d1. SNU478 was the cell line with the global gene expression pattern most similar to GBC, intrahepatic CCA, and extrahepatic CCA. EGFR, KMT2D, and KMT2C generally presented a higher expression in the investigated cell lines than in Japanese primary GBC tumors. We provide the scientific community with detailed mutation and gene expression data, together with three showcase applications, with the aim of facilitating the design of future in vitro cell culture assays for research on hepatobiliary cancer.

2.
Oral Surg Oral Med Oral Pathol Oral Radiol ; 125(5): 407-414.e1, 2018 05.
Artículo en Inglés | MEDLINE | ID: mdl-29402731

RESUMEN

OBJECTIVES: Reproduction of the exact preoperative proximal-mandible position after osteotomy in orthognathic surgery is difficult to achieve. This clinical pilot study evaluated an electromagnetic (EM) navigation system for condylar positioning after high-oblique sagittal split osteotomy (HSSO). STUDY DESIGN: After HSSO as part of 2-jaw surgery, the position of 10 condyles was intraoperatively guided by an EM navigation system. As controls, 10 proximal segments were positioned by standard manual replacement. Accuracy was measured by pre- and postoperative cone beam computed tomography imaging. RESULTS: Overall, EM condyle repositioning was equally accurate compared with manual repositioning (P > .05). Subdivided into 3 axes, significant differences could be identified (P < .05). Nevertheless, no significantly and clinically relevant dislocations of the proximal segment of either the EM or the manual repositioning method could be shown (P > .05). CONCLUSIONS: This pilot study introduces a guided method for proximal segment positioning after HSSO by applying the intraoperative EM system. The data demonstrate the high accuracy of EM navigation, although manual replacement of the condyles could not be surpassed. However, EM navigation can avoid clinically hidden, severe malpositioning of the condyles.


Asunto(s)
Fenómenos Electromagnéticos , Cóndilo Mandibular/cirugía , Osteotomía Sagital de Rama Mandibular/métodos , Cirugía Asistida por Computador/métodos , Adulto , Puntos Anatómicos de Referencia , Tomografía Computarizada de Haz Cónico , Femenino , Humanos , Imagenología Tridimensional , Masculino , Maloclusión Clase II de Angle/cirugía , Maloclusión de Angle Clase III/cirugía , Cóndilo Mandibular/diagnóstico por imagen , Proyectos Piloto , Estudios Prospectivos , Programas Informáticos , Cirugía Asistida por Computador/instrumentación
3.
J Craniomaxillofac Surg ; 45(5): 748-754, 2017 May.
Artículo en Inglés | MEDLINE | ID: mdl-28318915

RESUMEN

INTRODUCTION: Modifications of the temporomandibular joint position after mandible osteotomy are reluctantly accepted in orthognathic surgery. To tackle this problem, we developed a new navigation system using miniaturized electromagnetic sensors. Our imageless navigation approach is therefore optimized to avoid complications of previously proposed optical approaches such as the interference with established surgical procedures and the line of sight problem. MATERIAL AND METHODS: High oblique sagittal split osteotomies were performed on 6 plastic skull mandibles in a laboratory under conditions comparable to the operating theatre. The subsequent condyle reposition was guided by an intuitive user interface and performed by electromagnetic navigation. To prove the suitability and accuracy of this novel approach for condyle navigation, the positions of 3 titanium marker screws placed on each of the proximal segments were compared using pre- and postoperative Cone Beam Computed Tomography (CBCT) imaging. RESULTS: Guided by the electromagnetic navigation system, positioning of the condyles was highly accurate in all dimensions. Translational discrepancies up to 0,65 mm and rotations up to 0,38° in mean could be measured postoperatively. There were no statistically significant differences between navigation results and CBCT measurements. CONCLUSION: The intuitive user interface provides a simple way to precisely restore the initial position and orientation of the proximal mandibular segments. Our electromagnetic navigation system therefore yields a promising approach for orthognathic surgery applications.


Asunto(s)
Osteotomía Sagital de Rama Mandibular/métodos , Cirugía Asistida por Computador/métodos , Tomografía Computarizada de Haz Cónico , Fenómenos Electromagnéticos , Humanos , Mandíbula/diagnóstico por imagen , Mandíbula/cirugía , Cóndilo Mandibular/diagnóstico por imagen , Cóndilo Mandibular/cirugía , Osteotomía Sagital de Rama Mandibular/instrumentación , Cirugía Asistida por Computador/instrumentación
4.
Artículo en Inglés | MEDLINE | ID: mdl-28049608

RESUMEN

OBJECTIVES: Inaccuracies in orthognathic surgery can be caused during face-bow registration, model surgery on plaster models, and intermaxillary splint manufacturing. Electromagnetic (EM) navigation is a promising method for splintless digitized maxillary positioning. STUDY DESIGN: After performing Le Fort I osteotomy on 10 plastic skulls, the target position of the maxilla was guided by an EM navigation system. Specially implemented software illustrated the target position by real-time multistage colored three-dimensional imaging. Accuracy was determined by using pre- and postoperative cone beam computed tomography. RESULTS: The high accuracy of the EM system was underlined by the fact that it had a navigated maxilla position discrepancy of only 0.4 mm, which was verified by postoperative cone beam computed tomography. CONCLUSIONS: This preclinical study demonstrates a precise digitized approach for splintless maxillary repositioning after Le Fort I osteotomy. The accuracy and intuitive illustration of the introduced EM navigation system is promising for potential daily use in orthognathic surgery.


Asunto(s)
Fenómenos Electromagnéticos , Maxilar/cirugía , Procedimientos Quirúrgicos Ortognáticos/métodos , Osteotomía Le Fort , Tomografía Computarizada de Haz Cónico , Humanos , Imagenología Tridimensional , Técnicas In Vitro , Programas Informáticos
5.
J Craniomaxillofac Surg ; 45(10): 1593-1599, 2017 Oct.
Artículo en Inglés | MEDLINE | ID: mdl-28870648

RESUMEN

INTRODUCTION: Because of the inaccuracy of intermaxillary splints in orthognathic surgery, intraoperative guidance via a real time navigation system might represent a suitable method for enhancing the precision of maxillary positioning. Therefore, in this clinical trial, maxillary repositioning after Le Fort I osteotomy was guided splintless by an electromagnetic navigation system. MATERIALS AND METHODS: Conservatively planned maxillary reposition in each of 5 patients was transferred to a novel software module of the electromagnetic navigation system. Intraoperatively, after Le Fort I osteotomy, the software guided the maxilla to the targeted position. Accuracy was evaluated by pre- and postoperative cone beam computer tomography imaging (the vectorial distance of the incisal marker points was measured in three dimensions) and compared with that of a splint transposed control group. RESULTS: The repositioning of the maxilla guided by the electromagnetic navigation system was intuitive and simple to accomplish. The achieved maxillary position with a deviation of 0.7 mm on average to the planned position was equally accurate compared with that of the splint transposed control group of 0.5 mm (p > 0.05). DISCUSSION: The data of this clinical study display good accuracy for splintless electromagnetic-navigated maxillary positioning. Nevertheless, this method does not surpass the splint-encoded gold standard with regard to accuracy. Future investigations will be necessary to show the full potential of electromagnetic navigation in orthognathic surgery.


Asunto(s)
Maxilar/cirugía , Procedimientos Quirúrgicos Ortognáticos/métodos , Cirugía Asistida por Computador , Fenómenos Electromagnéticos , Humanos , Osteotomía Le Fort , Proyectos Piloto , Férulas (Fijadores)
6.
J Craniomaxillofac Surg ; 43(9): 1731-6, 2015 Nov.
Artículo en Inglés | MEDLINE | ID: mdl-26421472

RESUMEN

INTRODUCTION: Intraoperative guidance using electromagnetic navigation is an upcoming method in maxillofacial surgery. However, due to their unwieldy structures, especially the line-of-sight problem, optical navigation devices are not used for daily orthognathic surgery. Therefore, orthognathic surgery was simulated on study phantom skulls, evaluating the accuracy and handling of a new electromagnetic tracking system. MATERIAL AND METHODS: Le-Fort I osteotomies were performed on 10 plastic skulls. Orthognathic surgical planning was done in the conventional way using plaster models. Accuracy of the gold standard, splint-based model surgery versus an electromagnetic tracking system was evaluated by measuring the actual maxillary deviation using bimaxillary splints and preoperative and postoperative cone beam computer tomography imaging. The distance of five anatomical marker points were compared pre- and postoperatively. RESULTS: The electromagnetic tracking system was significantly more accurate in all measured parameters compared with the gold standard using bimaxillary splints (p < 0.01). The data shows a discrepancy between the model surgical plans and the actual correction of the upper jaw of 0.8 mm. Using the electromagnetic tracking, we could reduce the discrepancy of the maxillary transposition between the planned and actual orthognathic surgery to 0.3 mm on average. DISCUSSION: The data of this preliminary study shows a high level of accuracy in surgical orthognathic performance using electromagnetic navigation, and may offer greater precision than the conventional plaster model surgery with bimaxillary splints. CONCLUSION: This preliminary work shows great potential for the establishment of an intraoperative electromagnetic navigation system for maxillofacial surgery.


Asunto(s)
Fenómenos Electromagnéticos , Maxilar/cirugía , Procedimientos Quirúrgicos Ortognáticos/métodos , Cirugía Asistida por Computador/métodos , Humanos , Periodo Intraoperatorio , Modelos Anatómicos , Planificación de Atención al Paciente , Programas Informáticos , Interfaz Usuario-Computador
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA