Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 17 de 17
Filtrar
1.
Nature ; 529(7587): 509-514, 2016 Jan 28.
Artículo en Inglés | MEDLINE | ID: mdl-26819044

RESUMEN

Wearable sensor technologies are essential to the realization of personalized medicine through continuously monitoring an individual's state of health. Sampling human sweat, which is rich in physiological information, could enable non-invasive monitoring. Previously reported sweat-based and other non-invasive biosensors either can only monitor a single analyte at a time or lack on-site signal processing circuitry and sensor calibration mechanisms for accurate analysis of the physiological state. Given the complexity of sweat secretion, simultaneous and multiplexed screening of target biomarkers is critical and requires full system integration to ensure the accuracy of measurements. Here we present a mechanically flexible and fully integrated (that is, no external analysis is needed) sensor array for multiplexed in situ perspiration analysis, which simultaneously and selectively measures sweat metabolites (such as glucose and lactate) and electrolytes (such as sodium and potassium ions), as well as the skin temperature (to calibrate the response of the sensors). Our work bridges the technological gap between signal transduction, conditioning (amplification and filtering), processing and wireless transmission in wearable biosensors by merging plastic-based sensors that interface with the skin with silicon integrated circuits consolidated on a flexible circuit board for complex signal processing. This application could not have been realized using either of these technologies alone owing to their respective inherent limitations. The wearable system is used to measure the detailed sweat profile of human subjects engaged in prolonged indoor and outdoor physical activities, and to make a real-time assessment of the physiological state of the subjects. This platform enables a wide range of personalized diagnostic and physiological monitoring applications.


Asunto(s)
Monitoreo Fisiológico/instrumentación , Monitoreo Fisiológico/métodos , Sudor/química , Adulto , Ciclismo/fisiología , Agua Corporal , Calibración , Electrólitos/análisis , Femenino , Glucosa/análisis , Voluntarios Sanos , Humanos , Ácido Láctico/análisis , Masculino , Medicina de Precisión/instrumentación , Medicina de Precisión/métodos , Reproducibilidad de los Resultados , Carrera/fisiología , Piel , Temperatura Cutánea , Adulto Joven
2.
Nano Lett ; 16(7): 4047-53, 2016 07 13.
Artículo en Inglés | MEDLINE | ID: mdl-27322506

RESUMEN

Molybdenum disulfide (MoS2) has been widely examined as a catalyst containing no precious metals for the hydrogen evolution reaction (HER); however, these examinations have utilized synthesized MoS2 because the pristine MoS2 mineral is known to be a poor catalyst. The fundamental challenge with pristine MoS2 is the inert HER activity of the predominant (0001) basal surface plane. In order to achieve high HER performance with pristine MoS2, it is essential to activate the basal plane. Here, we report a general thermal process in which the basal plane is texturized to increase the density of HER-active edge sites. This texturization is achieved through a simple thermal annealing procedure in a hydrogen environment, removing sulfur from the MoS2 surface to form edge sites. As a result, the process generates high HER catalytic performance in pristine MoS2 across various morphologies such as the bulk mineral, films composed of micron-scale flakes, and even films of a commercially available spray of nanoflake MoS2. The lowest overpotential (η) observed for these samples was η = 170 mV to obtain 10 mA/cm(2) of HER current density.

3.
Nat Commun ; 12(1): 1823, 2021 03 23.
Artículo en Inglés | MEDLINE | ID: mdl-33758197

RESUMEN

The body naturally and continuously secretes sweat for thermoregulation during sedentary and routine activities at rates that can reflect underlying health conditions, including nerve damage, autonomic and metabolic disorders, and chronic stress. However, low secretion rates and evaporation pose challenges for collecting resting thermoregulatory sweat for non-invasive analysis of body physiology. Here we present wearable patches for continuous sweat monitoring at rest, using microfluidics to combat evaporation and enable selective monitoring of secretion rate. We integrate hydrophilic fillers for rapid sweat uptake into the sensing channel, reducing required sweat accumulation time towards real-time measurement. Along with sweat rate sensors, we integrate electrochemical sensors for pH, Cl-, and levodopa monitoring. We demonstrate patch functionality for dynamic sweat analysis related to routine activities, stress events, hypoglycemia-induced sweating, and Parkinson's disease. By enabling sweat analysis compatible with sedentary, routine, and daily activities, these patches enable continuous, autonomous monitoring of body physiology at rest.


Asunto(s)
Técnicas Biosensibles/instrumentación , Técnicas Biosensibles/métodos , Regulación de la Temperatura Corporal/fisiología , Microfluídica/métodos , Sudor/metabolismo , Sudoración/fisiología , Dispositivos Electrónicos Vestibles , Cuerpo Humano , Humanos , Concentración de Iones de Hidrógeno , Hipoglucemia/metabolismo , Levodopa/metabolismo , Microfluídica/instrumentación , Enfermedad de Parkinson/metabolismo , Descanso/fisiología , Estrés Fisiológico/fisiología , Sudor/fisiología , Caminata/fisiología
4.
Adv Mater ; 33(1): e2006444, 2021 Jan.
Artículo en Inglés | MEDLINE | ID: mdl-33225539

RESUMEN

Nutrients are essential for the healthy development and proper maintenance of body functions in humans. For adequate nourishment, it is important to keep track of nutrients level in the body, apart from consuming sufficient nutrition that is in line with dietary guidelines. Sweat, which contains rich chemical information, is an attractive biofluid for routine non-invasive assessment of nutrient levels. Herein, a wearable sensor that can selectively measure vitamin C concentration in biofluids, including sweat, urine, and blood is developed. Detection through an electrochemical sensor modified with Au nanostructures, LiClO4 -doped conductive polymer, and an enzymes-immobilized membrane is utilized to achieve wide detection linearity, high selectivity, and long-term stability. The sensor allows monitoring of temporal changes in vitamin C levels. The effect of vitamin C intake on the sweat and urine profile is explored by monitoring concentration changes upon consuming different amounts of vitamin C. A longitudinal study of sweat's and urine's vitamin C correlation with blood is performed on two individuals. The results suggest that sweat and urine analysis can be a promising method to routinely monitor nutrition through the sweat sensor and that this sensor can facilitate applications such as nutritional screening and dietary intervention.


Asunto(s)
Monitoreo Fisiológico/instrumentación , Evaluación Nutricional , Dispositivos Electrónicos Vestibles , Ácido Ascórbico/análisis , Humanos , Sudor/química
5.
Adv Mater ; 32(15): e1902083, 2020 Apr.
Artículo en Inglés | MEDLINE | ID: mdl-31432573

RESUMEN

The amalgamation of flexible electronics in biological systems has shaped the way health and medicine are administered. The growing field of flexible electrochemical bioelectronics enables the in situ quantification of a variety of chemical constituents present in the human body and holds great promise for personalized health monitoring owing to its unique advantages such as inherent wearability, high sensitivity, high selectivity, and low cost. It represents a promising alternative to probe biomarkers in the human body in a simpler method compared to conventional instrumental analytical techniques. Various bioanalytical technologies are employed in flexible electrochemical bioelectronics, including ion-selective potentiometry, enzymatic amperometry, potential sweep voltammetry, field-effect transistors, affinity-based biosensing, as well as biofuel cells. Recent key innovations in flexible electrochemical bioelectronics from electrochemical sensing modalities, materials, systems, fabrication, to applications are summarized and highlighted. The challenges and opportunities in this field moving forward toward future preventive and personalized medicine devices are also discussed.


Asunto(s)
Técnicas Biosensibles/métodos , Electrónica , Biomarcadores/análisis , Técnicas Biosensibles/instrumentación , Enzimas/metabolismo , Glucosa/análisis , Humanos , Potenciometría , Sudor/metabolismo , Dispositivos Electrónicos Vestibles
6.
Sci Adv ; 6(35): eabb8308, 2020 08.
Artículo en Inglés | MEDLINE | ID: mdl-32923646

RESUMEN

Sweat sensors targeting exercise or chemically induced sweat have shown promise for noninvasive health monitoring. Natural thermoregulatory sweat is an attractive alternative as it can be accessed during routine and sedentary activity without impeding user lifestyles and potentially preserves correlations between sweat and blood biomarkers. We present simple glove-based sensors to accumulate natural sweat with minimal evaporation, capitalizing on high sweat gland densities to collect hundreds of microliters in just 30 min without active sweat stimulation. Sensing electrodes are patterned on nitrile gloves and finger cots for in situ detection of diverse biomarkers, including electrolytes and xenobiotics, and multiple gloves or cots are worn in sequence to track overarching analyte dynamics. Direct integration of sensors into gloves represents a simple and low-overhead scheme for natural sweat analysis, enabling sweat-based physiological monitoring to become practical and routine without requiring highly complex or miniaturized components for analyte collection and signal transduction.

7.
ACS Sens ; 5(6): 1831-1837, 2020 06 26.
Artículo en Inglés | MEDLINE | ID: mdl-32429661

RESUMEN

The tobacco epidemic is a public health threat that has taken a heavy toll of lives around the globe each year. Smoking affects both the smokers and those who are exposed to secondhand smoke, and careful tracking of exposure can be key to mitigating the potential hazards. For smokers, the variation of chemical compositions between commercial cigarettes has led to ambiguity in estimating the health risks, both for active smokers and others involuntarily exposed to tobacco smoke and byproducts. In this regard, sweat possesses an attractive opportunity to monitor smoke exposure due to sweat's abundance in biomolecules and its great accessibility. Here, we present a wearable sweat band to monitor nicotine, a prominent ingredient in cigarettes, as a viable way to quantitatively assess a wearer's exposure to smoking. Both smokers and normal subjects are tested to demonstrate the use of this device for smoke-related health monitoring. Our results exhibit confirmable and elevated nicotine levels in sweat for subjects inhaling cigarette smoke. This continuous and personalized sweat sensing device is leverage to monitor smoke pollution for a potentially broad population.


Asunto(s)
Productos de Tabaco , Contaminación por Humo de Tabaco , Dispositivos Electrónicos Vestibles , Humanos , Nicotina/análisis , Sudor/química , Contaminación por Humo de Tabaco/análisis
8.
Nat Nanotechnol ; 15(1): 53-58, 2020 Jan.
Artículo en Inglés | MEDLINE | ID: mdl-31844286

RESUMEN

There is an emerging need for semiconductors that can be processed at near ambient temperature with high mobility and device performance. Although multiple n-type options have been identified, the development of their p-type counterparts remains limited. Here, we report the realization of tellurium thin films through thermal evaporation at cryogenic temperatures for fabrication of high-performance wafer-scale p-type field-effect transistors. We achieve an effective hole mobility of ~35 cm2 V-1 s-1, on/off current ratio of ~104 and subthreshold swing of 108 mV dec-1 on an 8-nm-thick film. High-performance tellurium p-type field-effect transistors are fabricated on a wide range of substrates including glass and plastic, further demonstrating the broad applicability of this material. Significantly, three-dimensional circuits are demonstrated by integrating multi-layered transistors on a single chip using sequential lithography, deposition and lift-off processes. Finally, various functional logic gates and circuits are demonstrated.

9.
Lab Chip ; 19(19): 3179-3189, 2019 10 07.
Artículo en Inglés | MEDLINE | ID: mdl-31433434

RESUMEN

Sweat sensors introduced in recent years have targeted a variety of sweat features and biomarkers for non-invasive health monitoring. Amongst these targets, reliable monitoring of sweat rate is crucial due to its modulation of sweat analyte concentrations and its intrinsic significance to numerous medical and physiological health conditions. Here we present a sweat rate sensor structure comprising of electrodes with interdigitated fingers in a microfluidic channel. Each time the accumulating sweat impinges on an electrode finger, the sensor reports a jump in admittance that can be simply and efficiently counted to estimate sweat rate, overcoming selectivity limitations of previously reported sweat rate sensors. We further integrate an impedimetric sensor for measuring total ionic charge concentration and an electrochemical Na+ sensor, together creating a multi-modal system for analyzing fluid and electrolyte secretion. We demonstrate how low analyte diffusion rates through this microfluidic device allow for multi-purpose sensor function, including utilizing the sweat rate sensor signal to corroborate total ionic sensor measurements. This cross-verification capability ensures data integrity in real time, satisfying a vital consideration for personalized healthcare technologies. We use the presented patch for continuous analysis of sweat rate, total ionic charge concentration, and Na+ concentration during exercise, while demonstrating how multi-modal cross-verification brings new trust to sensor readings.


Asunto(s)
Técnicas Biosensibles , Técnicas Electroquímicas , Sodio/análisis , Sudor/química , Biomarcadores/análisis , Técnicas Biosensibles/instrumentación , Técnicas Electroquímicas/instrumentación , Electrólitos/análisis , Humanos , Iones/análisis
10.
ACS Sens ; 4(7): 1925-1933, 2019 07 26.
Artículo en Inglés | MEDLINE | ID: mdl-31271034

RESUMEN

Wearable devices for health monitoring and fitness management have foreseen a rapidly expanding market, especially those for noninvasive and continuous measurements with real-time display that provide practical convenience and eliminated safety/infection risks. Herein, a self-powered and fully integrated smartwatch that consists of flexible photovoltaic cells and rechargeable batteries in the forms of a "watch strap", electrochemical glucose sensors, customized circuits, and display units integrated into a "dial" platform is successfully fabricated for real-time and continuous monitoring of sweat glucose levels. The functionality of the smartwatch, including sweat glucose sensing, signal processing, and display, can be supported with the harvested/converted solar energy without external charging devices. The Zn-MnO2 batteries serve as intermediate energy storage units and the utilization of aqueous electrolytes eliminated safety concerns for batteries, which is critical for wearable devices. Such a wearable system in a smartwatch fashion realizes integration of energy modules with self-powered capability, electrochemical sensors for noninvasive glucose monitoring, and in situ and real-time signal processing/display in a single platform for the first time. The as-fabricated fully integrated and self-powered smartwatch also provides a promising protocol for statistical study and clinical investigation to reveal correlations between sweat compositions and human body dynamics.


Asunto(s)
Técnicas Electroquímicas/métodos , Glucosa/análisis , Monitoreo Fisiológico/métodos , Sudor/química , Dispositivos Electrónicos Vestibles , Adulto , Técnicas Biosensibles/instrumentación , Técnicas Biosensibles/métodos , Suministros de Energía Eléctrica , Técnicas Electroquímicas/instrumentación , Diseño de Equipo , Ferrocianuros/química , Glucosa Oxidasa/química , Humanos , Masculino , Compuestos de Manganeso/química , Monitoreo Fisiológico/instrumentación , Níquel/química , Óxidos/química , Energía Solar , Adulto Joven , Zinc/química
11.
Sci Adv ; 5(8): eaaw9906, 2019 08.
Artículo en Inglés | MEDLINE | ID: mdl-31453333

RESUMEN

Recent technological advancements in wearable sensors have made it easier to detect sweat components, but our limited understanding of sweat restricts its application. A critical bottleneck for temporal and regional sweat analysis is achieving uniform, high-throughput fabrication of sweat sensor components, including microfluidic chip and sensing electrodes. To overcome this challenge, we introduce microfluidic sensing patches mass fabricated via roll-to-roll (R2R) processes. The patch allows sweat capture within a spiral microfluidic for real-time measurement of sweat parameters including [Na+], [K+], [glucose], and sweat rate in exercise and chemically induced sweat. The patch is demonstrated for investigating regional sweat composition, predicting whole-body fluid/electrolyte loss during exercise, uncovering relationships between sweat metrics, and tracking glucose dynamics to explore sweat-to-blood correlations in healthy and diabetic individuals. By enabling a comprehensive sweat analysis, the presented device is a crucial tool for advancing sweat testing beyond the research stage for point-of-care medical and athletic applications.


Asunto(s)
Glucosa/análisis , Microfluídica/métodos , Potasio/análisis , Sodio/análisis , Sudor/química , Técnicas Biosensibles , Diabetes Mellitus/metabolismo , Ensayos Analíticos de Alto Rendimiento , Humanos , Iones/análisis , Potasio/química , Sodio/química
12.
ACS Sens ; 3(5): 944-952, 2018 05 25.
Artículo en Inglés | MEDLINE | ID: mdl-29741360

RESUMEN

Wearable sweat sensing is a rapidly rising research area driven by its promising potential in health, fitness, and diagnostic applications. Despite the growth in the field, major challenges in relation to sweat metrics remain to be addressed. These challenges include sweat rate monitoring for its complex relation with sweat compositions and sweat sampling for sweat dynamics studies. In this work, we present a flexible microfluidic sweat sensing patch that enhances real-time electrochemical sensing and sweat rate analysis via sweat sampling. The device contains a spiral-patterned microfluidic component that is embedded with ion-selective sensors and an electrical impedance-based sweat rate sensor on a flexible plastic substrate. The patch is enabled to autonomously perform sweat analysis by interfacing the sensing component with a printed circuit board that is capable of on-site signal conditioning, analysis, and transmission. Progressive sweat flow in the microfluidic device, governed by the pressure induced by the secreted sweat, enhances sweat sampling and electrochemical detection via a defined sweat collection chamber and a directed sweat route. The characteristic of the sweat rate sensor is validated through a theoretical simulation, and the precision and accuracy of the flow rate is verified with a commercial syringe pump and a Macroduct sweat collector. On-body simultaneous monitoring of ion (H+, Na+, K+, Cl-) concentration and sweat rate is also demonstrated for sensor functionality. This sweat sensing patch provides an integrated platform for a comprehensive sweat secretion analysis and facilitates physiological and clinical investigations by closely monitoring interrelated sweat parameters.


Asunto(s)
Dispositivos Laboratorio en un Chip , Sudor , Dispositivos Electrónicos Vestibles , Humanos , Ondas de Radio , Teléfono Inteligente
13.
ACS Nano ; 12(7): 6978-6987, 2018 07 24.
Artículo en Inglés | MEDLINE | ID: mdl-29924589

RESUMEN

As recent developments in noninvasive biosensors spearhead the thrust toward personalized health and fitness monitoring, there is a need for high throughput, cost-effective fabrication of flexible sensing components. Toward this goal, we present roll-to-roll (R2R) gravure printed electrodes that are robust under a range of electrochemical sensing applications. We use inks and electrode morphologies designed for electrochemical and mechanical stability, achieving devices with uniform redox kinetics printed on 150 m flexible substrate rolls. We show that these electrodes can be functionalized into consistently high performing sensors for detecting ions, metabolites, heavy metals, and other small molecules in noninvasively accessed biofluids, including sensors for real-time, in situ perspiration monitoring during exercise. This development of robust and versatile R2R gravure printed electrodes represents a key translational step in enabling large-scale, low-cost fabrication of disposable wearable sensors for personalized health monitoring applications.


Asunto(s)
Técnicas Electroquímicas/instrumentación , Impresión , Dispositivos Electrónicos Vestibles , Electrodos
14.
ACS Sens ; 2(7): 990-997, 2017 Jul 28.
Artículo en Inglés | MEDLINE | ID: mdl-28721726

RESUMEN

Real-time detection of basic physiological parameters such as blood pressure and heart rate is an important target in wearable smart devices for healthcare. Among these, the core body temperature is one of the most important basic medical indicators of fever, insomnia, fatigue, metabolic functionality, and depression. However, traditional wearable temperature sensors are based upon the measurement of skin temperature, which can vary dramatically from the true core body temperature. Here, we demonstrate a three-dimensional (3D) printed wearable "earable" smart device that is designed to be worn on the ear to track core body temperature from the tympanic membrane (i.e., ear drum) based on an infrared sensor. The device is fully integrated with data processing circuits and a wireless module for standalone functionality. Using this smart earable device, we demonstrate that the core body temperature can be accurately monitored regardless of the environment and activity of the user. In addition, a microphone and actuator are also integrated so that the device can also function as a bone conduction hearing aid. Using 3D printing as the fabrication method enables the device to be customized for the wearer for more personalized healthcare. This smart device provides an important advance in realizing personalized health care by enabling real-time monitoring of one of the most important medical parameters, core body temperature, employed in preliminary medical screening tests.

15.
Adv Mater ; 28(22): 4396, 2016 Jun.
Artículo en Inglés | MEDLINE | ID: mdl-27273439

RESUMEN

Printed electronics and sensors enable new applications ranging from low-cost disposable analytical devices to large-area sensor networks. Recent progress in printed carbon nanotube electronics in terms of materials, processing, devices, and applications is discussed on page 4397 by A. Javey and co-workers. The research challenges and opportunities regarding the processing and system-level integration are also discussed for enabling of practical applications.

16.
ACS Nano ; 10(7): 7216-24, 2016 07 26.
Artículo en Inglés | MEDLINE | ID: mdl-27380446

RESUMEN

Homeostasis of ionized calcium in biofluids is critical for human biological functions and organ systems. Measurement of ionized calcium for clinical applications is not easily accessible due to its strict procedures and dependence on pH. pH balance in body fluids greatly affects metabolic reactions and biological transport systems. Here, we demonstrate a wearable electrochemical device for continuous monitoring of ionized calcium and pH of body fluids using a disposable and flexible array of Ca(2+) and pH sensors that interfaces with a flexible printed circuit board. This platform enables real-time quantitative analysis of these sensing elements in body fluids such as sweat, urine, and tears. Accuracy of Ca(2+) concentration and pH measured by the wearable sensors is validated through inductively coupled plasma-mass spectrometry technique and a commercial pH meter, respectively. Our results show that the wearable sensors have high repeatability and selectivity to the target ions. Real-time on-body assessment of sweat is also performed, and our results indicate that calcium concentration increases with decreasing pH. This platform can be used in noninvasive continuous analysis of ionized calcium and pH in body fluids for disease diagnosis such as primary hyperparathyroidism and kidney stones.


Asunto(s)
Calcio/análisis , Sudor/química , Dispositivos Electrónicos Vestibles , Electrólitos , Humanos , Concentración de Iones de Hidrógeno , Iones
17.
Adv Mater ; 28(22): 4397-414, 2016 Jun.
Artículo en Inglés | MEDLINE | ID: mdl-26880046

RESUMEN

Printing technologies offer large-area, high-throughput production capabilities for electronics and sensors on mechanically flexible substrates that can conformally cover different surfaces. These capabilities enable a wide range of new applications such as low-cost disposable electronics for health monitoring and wearables, extremely large format electronic displays, interactive wallpapers, and sensing arrays. Solution-processed carbon nanotubes have been shown to be a promising candidate for such printing processes, offering stable devices with high performance. Here, recent progress made in printed carbon nanotube electronics is discussed in terms of materials, processing, devices, and applications. Research challenges and opportunities moving forward from processing and system-level integration points of view are also discussed for enabling practical applications.

SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA