Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 3 de 3
Filtrar
Más filtros

Bases de datos
Tipo del documento
Asunto de la revista
Intervalo de año de publicación
1.
Phys Rev Lett ; 123(13): 134801, 2019 Sep 27.
Artículo en Inglés | MEDLINE | ID: mdl-31697514

RESUMEN

An intense, subpicosecond, relativistic electron beam traversing a dielectric-lined waveguide generates very large amplitude electric fields at terahertz (THz) frequencies through the wakefield mechanism. In recent work employing this technique to accelerate charged particles, the generation of high-power, narrow-band THz radiation was demonstrated. The radiated waves contain fields with measured amplitude exceeding 2 GV/m, orders of magnitude greater than those available by other THz generation techniques at a narrow bandwidth. For fields approaching the GV/m level, a strong damping has been observed in SiO_{2}. This wave attenuation with an onset near 850 MV/m is consistent with changes to the conductivity of the dielectric lining and is characterized by a distinctive latching mechanism that is reversible on longer timescales. We describe the detailed measurements that serve to clarify the underlying physical mechanisms leading to strong field-induced damping of THz radiation (hω=1.59 meV, f=0.38 THz) in SiO_{2}, a bulk, wide band-gap (8.9 eV) dielectric.

2.
Phys Rev Lett ; 120(12): 124802, 2018 Mar 23.
Artículo en Inglés | MEDLINE | ID: mdl-29694092

RESUMEN

Hollow channel plasma wakefield acceleration is a proposed method to provide high acceleration gradients for electrons and positrons alike: a key to future lepton colliders. However, beams which are misaligned from the channel axis induce strong transverse wakefields, deflecting beams and reducing the collider luminosity. This undesirable consequence sets a tight constraint on the alignment accuracy of the beam propagating through the channel. Direct measurements of beam misalignment-induced transverse wakefields are therefore essential for designing mitigation strategies. We present the first quantitative measurements of transverse wakefields in a hollow plasma channel, induced by an off-axis 20 GeV positron bunch, and measured with another 20 GeV lower charge trailing positron probe bunch. The measurements are largely consistent with theory.

3.
Nat Commun ; 7: 12763, 2016 09 14.
Artículo en Inglés | MEDLINE | ID: mdl-27624348

RESUMEN

There is urgent need to develop new acceleration techniques capable of exceeding gigaelectron-volt-per-metre (GeV m(-1)) gradients in order to enable future generations of both light sources and high-energy physics experiments. To address this need, short wavelength accelerators based on wakefields, where an intense relativistic electron beam radiates the demanded fields directly into the accelerator structure or medium, are currently under intense investigation. One such wakefield based accelerator, the dielectric wakefield accelerator, uses a dielectric lined-waveguide to support a wakefield used for acceleration. Here we show gradients of 1.347±0.020 GeV m(-1) using a dielectric wakefield accelerator of 15 cm length, with sub-millimetre transverse aperture, by measuring changes of the kinetic state of relativistic electron beams. We follow this measurement by demonstrating accelerating gradients of 320±17 MeV m(-1). Both measurements improve on previous measurements by and order of magnitude and show promise for dielectric wakefield accelerators as sources of high-energy electrons.

SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA