Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 222
Filtrar
Más filtros

Bases de datos
País/Región como asunto
Tipo del documento
Intervalo de año de publicación
1.
Artículo en Inglés | MEDLINE | ID: mdl-38965873

RESUMEN

INTRODUCTION: Atrial remodelling (AR) is the persistent change in atrial structure and/or function and contributes to the initiation, maintenance and progression of atrial fibrillation (AF) in a reciprocal self-perpetuating relationship. Left atrial (LA) size, geometry, fibrosis, wall thickness (LAWT) and ejection fraction (LAEF) have all been shown to vary with pathological atrial remodelling. The association of these global remodelling markers with each other for differentiating structural phenotypes in AF is not well investigated. METHOD: Patients referred for first-time AF ablation and controls without AF were prospectively recruited to undergo cardiac computed tomographic angiography (CCTA) and magnetic resonance imaging (MRI) with 3D atrial late-gadolinium enhanced (LGE) sequences. LAWT, atrial myocardial mass, LA volume and sphericity were calculated from CT. Biplane LA EF and LA fibrosis burden were derived from atrial MRI. Results were compared between patients with AF and controls. RESULTS: Forty two AF patients (64.3% male, age 64.6 ± 10.2 years, CHA2DS2-VASc 2.48 ± 1.5, 69.0% paroxysmal AF, 31% persistent AF, LVEF 57.9 ± 10.5%) and 37 controls (64.9% male, age 56.6 ± 7.2, CHA2DS2-VASc 1.54 ± 1.1, LVEF 60.4 ± 4.9%) were recruited. Patients with AF had a significantly higher LAWT (1.45 ± 0.52 mm vs 1.12 ± 0.42 mm, p = 0.003), tissue mass (15.81 ± 6.53 g vs. 12.18 ± 5.01 g, p = 0.011), fibrosis burden (9.33 ± 8.35% vs 2.41 ± 3.60%, p = 0.013), left atrial size/volume (95.68 ± 26.63 mL vs 81.22 ± 20.64 mL, p = 0.011) and lower LAEF (50.3 ± 15.3% vs 65.2 ± 8.6%, p < 0.001) compared to controls. There was no significant correlation between % fibrosis with LAWT (p = 0.29), mass (p = 0.89), volume (p = 0.49) or sphericity (p = 0.79). LAWT had a statistically significant weak positive correlation with LA volume (r = 0.25, p = .041), but not with sphericity (p = 0.86). LAEF had a statistically significant but weak negative correlation with fibrosis (r = -0.33, p = 0.008) and LAWT (r = -0.24, p = 0.07). CONCLUSION: AF is associated with significant quantifiable structural changes that are evident in LA size, tissue thickness, total LA tissue mass and fibrosis. These individual remodelling markers do not or only weakly correlate with each other suggesting different remodelling subtypes exist (e.g. fibrotic vs hypertrophic vs dilated). If confirmed, such a detailed understanding of the structural changes observed has the potential to inform clinical management strategies targeting individual mechanisms underlying the disease process.

2.
Europace ; 26(4)2024 Mar 30.
Artículo en Inglés | MEDLINE | ID: mdl-38587017

RESUMEN

In the last three decades, ablation of atrial fibrillation (AF) has become an evidence-based safe and efficacious treatment for managing the most common cardiac arrhythmia. In 2007, the first joint expert consensus document was issued, guiding healthcare professionals involved in catheter or surgical AF ablation. Mounting research evidence and technological advances have resulted in a rapidly changing landscape in the field of catheter and surgical AF ablation, thus stressing the need for regularly updated versions of this partnership which were issued in 2012 and 2017. Seven years after the last consensus, an updated document was considered necessary to define a contemporary framework for selection and management of patients considered for or undergoing catheter or surgical AF ablation. This consensus is a joint effort from collaborating cardiac electrophysiology societies, namely the European Heart Rhythm Association, the Heart Rhythm Society, the Asia Pacific Heart Rhythm Society, and the Latin American Heart Rhythm Society .


Asunto(s)
Fibrilación Atrial , Ablación por Catéter , Humanos , Fibrilación Atrial/diagnóstico , Fibrilación Atrial/cirugía , América Latina , Resultado del Tratamiento , Catéteres , Asia , Ablación por Catéter/efectos adversos , Ablación por Catéter/métodos
4.
Europace ; 25(2): 469-477, 2023 02 16.
Artículo en Inglés | MEDLINE | ID: mdl-36369980

RESUMEN

AIMS: Existing strategies that identify post-infarct ventricular tachycardia (VT) ablation target either employ invasive electrophysiological (EP) mapping or non-invasive modalities utilizing the electrocardiogram (ECG). Their success relies on localizing sites critical to the maintenance of the clinical arrhythmia, not always recorded on the 12-lead ECG. Targeting the clinical VT by utilizing electrograms (EGM) recordings stored in implanted devices may aid ablation planning, enhancing safety and speed and potentially reducing the need of VT induction. In this context, we aim to develop a non-invasive computational-deep learning (DL) platform to localize VT exit sites from surface ECGs and implanted device intracardiac EGMs. METHODS AND RESULTS: A library of ECGs and EGMs from simulated paced beats and representative post-infarct VTs was generated across five torso models. Traces were used to train DL algorithms to localize VT sites of earliest systolic activation; first tested on simulated data and then on a clinically induced VT to show applicability of our platform in clinical settings. Localization performance was estimated via localization errors (LEs) against known VT exit sites from simulations or clinical ablation targets. Surface ECGs successfully localized post-infarct VTs from simulated data with mean LE = 9.61 ± 2.61 mm across torsos. VT localization was successfully achieved from implanted device intracardiac EGMs with mean LE = 13.10 ± 2.36 mm. Finally, the clinically induced VT localization was in agreement with the clinical ablation volume. CONCLUSION: The proposed framework may be utilized for direct localization of post-infarct VTs from surface ECGs and/or implanted device EGMs, or in conjunction with efficient, patient-specific modelling, enhancing safety and speed of ablation planning.


Asunto(s)
Ablación por Catéter , Aprendizaje Profundo , Taquicardia Ventricular , Humanos , Técnicas Electrofisiológicas Cardíacas , Taquicardia Ventricular/diagnóstico , Taquicardia Ventricular/etiología , Taquicardia Ventricular/cirugía , Electrocardiografía/métodos , Infarto/cirugía
5.
Dev Med Child Neurol ; 2023 Nov 10.
Artículo en Inglés | MEDLINE | ID: mdl-37946550

RESUMEN

AIM: To assess the risks, benefits, and resource implications of home-blended food for children with gastrostomy tubes compared with a formula diet. METHOD: This prospective cohort study of children (aged 0-18 years) collected baseline data on gastrointestinal symptoms, nutritional intake, anthropometric outcomes, parent and child quality of life, and resource use. A propensity score-weighted generalized linear mixed model was used to compare children receiving a home-blended versus formula diet. RESULTS: Baseline data were obtained for 180 children (2019-2021; 107 males, 73 females; mean age 9 years 7 months [SD 4 years 5 months]). Children receiving a home-blended diet (n = 104) had similar diagnoses and age but more lived in areas of lower deprivation and parental education was higher compared to the parents of children receiving a formula diet (n = 76). Children receiving home-blended diets had significantly better gastrointestinal scores than those receiving formula diets (B = 13.8, p < 0.001). The number of gut infections and tube blockages were similar between the two groups but with fewer stoma site infections in the group receiving home-blended food. Children receiving a home-blended diet had more fibre in their diet compared to children receiving a formula diet. INTERPRETATION: Home-blended diets should be seen as a safe option for children who are gastrostomy-fed unless clinically contraindicated. Equality of access to home-blended diets for children with gastrostomy should be assessed by local clinical teams.

6.
PLoS Comput Biol ; 17(4): e1008851, 2021 04.
Artículo en Inglés | MEDLINE | ID: mdl-33857152

RESUMEN

Cardiac anatomy plays a crucial role in determining cardiac function. However, there is a poor understanding of how specific and localised anatomical changes affect different cardiac functional outputs. In this work, we test the hypothesis that in a statistical shape model (SSM), the modes that are most relevant for describing anatomy are also most important for determining the output of cardiac electromechanics simulations. We made patient-specific four-chamber heart meshes (n = 20) from cardiac CT images in asymptomatic subjects and created a SSM from 19 cases. Nine modes captured 90% of the anatomical variation in the SSM. Functional simulation outputs correlated best with modes 2, 3 and 9 on average (R = 0.49 ± 0.17, 0.37 ± 0.23 and 0.34 ± 0.17 respectively). We performed a global sensitivity analysis to identify the different modes responsible for different simulated electrical and mechanical measures of cardiac function. Modes 2 and 9 were the most important for determining simulated left ventricular mechanics and pressure-derived phenotypes. Mode 2 explained 28.56 ± 16.48% and 25.5 ± 20.85, and mode 9 explained 12.1 ± 8.74% and 13.54 ± 16.91% of the variances of mechanics and pressure-derived phenotypes, respectively. Electrophysiological biomarkers were explained by the interaction of 3 ± 1 modes. In the healthy adult human heart, shape modes that explain large portions of anatomical variance do not explain equivalent levels of electromechanical functional variation. As a result, in cardiac models, representing patient anatomy using a limited number of modes of anatomical variation can cause a loss in accuracy of simulated electromechanical function.


Asunto(s)
Corazón/fisiología , Modelos Cardiovasculares , Adulto , Voluntarios Sanos , Corazón/anatomía & histología , Humanos , Tomografía Computarizada por Rayos X
7.
Qual Life Res ; 31(5): 1415-1425, 2022 May.
Artículo en Inglés | MEDLINE | ID: mdl-34618326

RESUMEN

PURPOSE: Few studies have examined specific cognitive and behavioural responses to symptoms, which may impact health-related outcomes, in conjunction with illness representations, as outlined by the Common-Sense-Model. Patients with atrial fibrillation (AF) report poor quality-of-life (QoL) and high distress. This cross-sectional study investigated patterns/clusters of cognitive and behavioural responses to illness, and illness perceptions, and relationships with QoL, depression and anxiety. METHODS: AF patients (N = 198) recruited at cardiology clinics completed the AF-Revised Illness Perception Questionnaire, Atrial-Fibrillation-Effect-on-Quality-of-Life Questionnaire, Patient Health Questionnaire-8 and Generalized Anxiety Disorder Questionnaire. Cluster analysis used Ward's and K-means methods. Hierarchical regressions examined relationships between clusters with QoL, depression and anxiety. RESULTS: Two clusters of cognitive and behavioural responses to symptoms were outlined; (1) 'high avoidance'; (2) 'low symptom-focussing'. Patients in Cluster 1 had lower QoL (M = 40.36, SD = 18.40), greater symptoms of depression (M = 7.20, SD = 5.71) and greater symptoms of anxiety (M = 5.70, SD = 5.90) compared to patients in Cluster 2 who had higher QoL (M = 59.03, SD = 20.12), fewer symptoms of depression (M = 3.53, SD = 3.56) and fewer symptoms of anxiety (M = 2.56, SD = 3.56). Two illness representation clusters were outlined; (1) 'high coherence and treatment control', (2) 'negative illness and emotional representations'. Patients in Cluster 2 had significantly lower QoL (M = 46.57, SD = 19.94), greater symptoms of depression (M = 6.12, SD = 5.31) and greater symptoms of anxiety (M = 4.70, SD = 5.27), compared with patients in Cluster 1 who had higher QoL (M = 61.52, SD = 21.38), fewer symptoms of depression (M = 2.85, SD = 2.97) and fewer symptoms of anxiety (M = 2.16, SD = 3.63). Overall, clusters of cognitive and behavioural responses to symptoms, and illness perceptions significantly explained between 14 and 29% of the variance in QoL, depression and anxiety. CONCLUSION: Patterns of cognitive and behavioural responses to symptoms, and illness perceptions are important correlates of health-related outcomes in AF patients.


Asunto(s)
Fibrilación Atrial , Calidad de Vida , Ansiedad/psicología , Fibrilación Atrial/psicología , Análisis por Conglomerados , Cognición , Estudios Transversales , Depresión/psicología , Humanos , Calidad de Vida/psicología , Encuestas y Cuestionarios
8.
Europace ; 23(23 Suppl 1): i12-i20, 2021 03 04.
Artículo en Inglés | MEDLINE | ID: mdl-33437987

RESUMEN

AIMS: Atrial fibrillation (AF) is sustained by re-entrant activation patterns. Ablation strategies have been proposed that target regions of tissue that may support re-entrant activation patterns. We aimed to characterize the tissue properties associated with regions that tether re-entrant activation patterns in a validated virtual patient cohort. METHODS AND RESULTS: Atrial fibrillation patient-specific models (seven paroxysmal and three persistent) were generated and validated against local activation time (LAT) measurements during an S1-S2 pacing protocol from the coronary sinus and high right atrium, respectively. Atrial models were stimulated with burst pacing from three locations in the proximity of each pulmonary vein to initiate re-entrant activation patterns. Five atria exhibited sustained activation patterns for at least 80 s. Models with short maximum action potential durations (APDs) were associated with sustained activation. Phase singularities were mapped across the atria sustained activation patterns. Regions with a low maximum conduction velocity (CV) were associated with tethering of phase singularities. A support vector machine (SVM) was trained on maximum local conduction velocity and action potential duration to identify regions that tether phase singularities. The SVM identified regions of tissue that could support tethering with 91% accuracy. This accuracy increased to 95% when the SVM was also trained on surface area. CONCLUSION: In a virtual patient cohort, local tissue properties, that can be measured (CV) or estimated (APD; using effective refractory period as a surrogate) clinically, identified regions of tissue that tether phase singularities. Combing CV and APD with atrial surface area further improved the accuracy in identifying regions that tether phase singularities.


Asunto(s)
Fibrilación Atrial , Potenciales de Acción , Fibrilación Atrial/diagnóstico , Fibrilación Atrial/cirugía , Atrios Cardíacos/cirugía , Humanos , Aprendizaje Automático
9.
Dev Med Child Neurol ; 63(9): 1099-1106, 2021 09.
Artículo en Inglés | MEDLINE | ID: mdl-33792913

RESUMEN

AIM: To identify child and parent outcomes relevant to having a gastrostomy, and to specify outcomes believed to be particularly salient to type of diet (formula vs blended food). METHOD: Twenty parents, two children (both 12y), and 41 professionals (dietitians [n=10]; nurses [n=12]; paediatricians [n=12]; speech and language therapists [n=7)]) were recruited. Parents and children were interviewed; professionals participated in focus groups. Children (2-18y) represented included those on formula (n=11), blended-food (n=7), and mixed (n=2) diets. All had been tube-fed for at least 6 months. Neurological, genetic, and metabolic conditions were represented. RESULTS: Participants identified a range of children's outcomes relevant to a gastrostomy, including physical health, gastrointestinal symptoms, sleep, and time spent feeding. The children described experiences of exclusion caused by being tube-fed. Time, sleep, and emotional health were regarded as most salient to understanding parents' gastrostomy outcomes. Participants believed type of diet would most likely effect gastrointestinal symptoms, time spent feeding, sleep, and physical health. INTERPRETATION: Findings indicate a number of refinements to, and allow further specification of, the current 'initial' core outcome set for tube-fed children. Findings also have implications for choice of outcomes measures. Further qualitative research with children and young people is needed. What this paper adds Sleep is a key outcome for children and parents. Gastrointestinal symptoms and physical health were regarded as outcomes most likely to be affected by type of diet. Well-being and participation were identified as key distal outcomes. Gastrostomies are complex interventions. Further specification of the core outcome set is possible.


Asunto(s)
Dieta/métodos , Nutrición Enteral/psicología , Gastrostomía/psicología , Padres/psicología , Investigación Cualitativa , Adolescente , Niño , Preescolar , Dieta/efectos adversos , Dieta/psicología , Nutrición Enteral/instrumentación , Femenino , Alimentos , Personal de Salud , Humanos , Masculino , Calidad de Vida
10.
MAGMA ; 34(6): 877-887, 2021 Dec.
Artículo en Inglés | MEDLINE | ID: mdl-34165670

RESUMEN

OBJECTIVE: 3D late gadolinium enhancement (LGE) imaging is a promising non-invasive technique for the assessment of atrial fibrosis. However, current techniques result in prolonged and unpredictable scan times and high rates of non-diagnostic images. The purpose of this study was to compare the performance of a recently proposed accelerated respiratory motion-compensated 3D water/fat LGE technique with conventional 3D LGE for atrial wall imaging. MATERIALS AND METHODS: 18 patients (age: 55.7±17.1 years) with atrial fibrillation underwent conventional diaphragmatic navigator gated inversion recovery (IR)-prepared 3D LGE (dNAV) and proposed image-navigator motion-corrected water/fat IR-prepared 3D LGE (iNAV) imaging. Images were assessed for image quality and presence of fibrosis by three expert observers. The scan time for both techniques was recorded. RESULTS: Image quality scores were improved with the proposed compared to the conventional method (iNAV: 3.1 ± 1.0 vs. dNAV: 2.6 ± 1.0, p = 0.0012, with 1: Non-diagnostic to 4: Full diagnostic). Furthermore, scan time for the proposed method was significantly shorter with a 59% reduction is scan time (4.5 ± 1.2 min vs. 10.9 ± 3.9 min, p < 0.0001). The images acquired with the proposed method were deemed as inconclusive less frequently than the conventional images (expert 1/expert 2: 4/7 dNAV and 2/4 iNAV images inconclusive). DISCUSSION: The motion-compensated water/fat LGE method enables atrial wall imaging with diagnostic quality comparable to the current conventional approach with a significantly shorter scan of about 5 min.


Asunto(s)
Medios de Contraste , Gadolinio , Adulto , Anciano , Humanos , Imagenología Tridimensional , Imagen por Resonancia Magnética , Persona de Mediana Edad , Agua
11.
Philos Trans A Math Phys Eng Sci ; 378(2173): 20190345, 2020 Jun 12.
Artículo en Inglés | MEDLINE | ID: mdl-32448072

RESUMEN

In patients with atrial fibrillation, local activation time (LAT) maps are routinely used for characterizing patient pathophysiology. The gradient of LAT maps can be used to calculate conduction velocity (CV), which directly relates to material conductivity and may provide an important measure of atrial substrate properties. Including uncertainty in CV calculations would help with interpreting the reliability of these measurements. Here, we build upon a recent insight into reduced-rank Gaussian processes (GPs) to perform probabilistic interpolation of uncertain LAT directly on human atrial manifolds. Our Gaussian process manifold interpolation (GPMI) method accounts for the topology of the atrium, and allows for calculation of statistics for predicted CV. We demonstrate our method on two clinical cases, and perform validation against a simulated ground truth. CV uncertainty depends on data density, wave propagation direction and CV magnitude. GPMI is suitable for probabilistic interpolation of other uncertain quantities on non-Euclidean manifolds. This article is part of the theme issue 'Uncertainty quantification in cardiac and cardiovascular modelling and simulation'.


Asunto(s)
Función Atrial , Sistema de Conducción Cardíaco/fisiología , Modelos Cardiovasculares , Fibrilación Atrial/patología , Fibrilación Atrial/fisiopatología , Atrios Cardíacos/patología , Atrios Cardíacos/fisiopatología , Sistema de Conducción Cardíaco/fisiopatología , Humanos , Distribución Normal , Probabilidad
12.
J Cardiovasc Nurs ; 35(4): 337-346, 2020.
Artículo en Inglés | MEDLINE | ID: mdl-32084080

RESUMEN

BACKGROUND/OBJECTIVES: This study examined whether beliefs about medicines, drug attitudes, and depression independently predicted anticoagulant and antiarrhythmic adherence (focusing on the implementation phase of nonadherence) in patients with atrial fibrillation (AF). METHODS: This cross-sectional study was part of a larger longitudinal study. Patients with AF (N = 118) completed the Patient Health Questionnaire-8. The Beliefs about Medicines Questionnaire, Drug Attitude Inventory, and Morisky-Green-Levine Medication Adherence Scale (self-report adherence measure), related to anticoagulants and antiarrhythmics, were also completed. Correlation and multiple logistic regression analyses were conducted. RESULTS: There were no significant differences in nonadherence to anticoagulants or antiarrhythmics. Greater concerns (r = 0.23, P = .01) were significantly, positively associated with anticoagulant nonadherence only. Depression and drug attitudes were not significantly associated with anticoagulant/antiarrhythmic adherence. Predictors reliably distinguished adherers and nonadherers to anticoagulant medication in the regression model, explaining 14% of the variance, but only concern beliefs (odds ratio, 1.20) made a significant independent contribution to prediction (χ = 11.40, P = .02, with df = 4). When entered independently into a regression model, concerns (odds ratio, 1.24) significantly explained 10.3% of the variance (χ = 7.97, P = .01, with df = 1). Regressions were not significant for antiarrhythmic medication (P = .30). CONCLUSIONS: Specifying medication type is important when examining nonadherence in chronic conditions. Concerns about anticoagulants, rather than depression, were significantly associated with nonadherence to anticoagulants but not antiarrhythmics. Anticoagulant concerns should be targeted at AF clinics, with an aim to reduce nonadherence and potentially modifiable adverse outcomes such as stroke.


Asunto(s)
Fibrilación Atrial/psicología , Conocimientos, Actitudes y Práctica en Salud , Cumplimiento de la Medicación/psicología , Aceptación de la Atención de Salud/psicología , Cooperación del Paciente/psicología , Adulto , Anciano , Anticoagulantes/uso terapéutico , Fibrilación Atrial/tratamiento farmacológico , Fibrilación Atrial/fisiopatología , Estudios Transversales , Depresión/psicología , Femenino , Humanos , Masculino , Cumplimiento de la Medicación/estadística & datos numéricos , Persona de Mediana Edad , Aceptación de la Atención de Salud/estadística & datos numéricos , Cooperación del Paciente/estadística & datos numéricos , Encuestas y Cuestionarios
13.
Biophys J ; 117(12): 2361-2374, 2019 12 17.
Artículo en Inglés | MEDLINE | ID: mdl-31521328

RESUMEN

The development of effective and safe therapies for scar-related ventricular tachycardias requires a detailed understanding of the mechanisms underlying the conduction block that initiates electrical re-entries associated with these arrhythmias. Conduction block has been often associated with electrophysiological changes that prolong action potential duration (APD) within the border zone (BZ) of chronically infarcted hearts. However, experimental evidence suggests that remodeling processes promoting conduction slowing as opposed to APD prolongation mark the chronic phase. In this context, the substrate for the initial block at the mouth of an isthmus/diastolic channel leading to ventricular tachycardia is unclear. The goal of this study was to determine whether electrophysiological parameters associated with conduction slowing can cause block and re-entry in the BZ. In silico experiments were conducted on two-dimensional idealized infarct tissue as well as on a cohort of postinfarction porcine left ventricular models constructed from ex vivo magnetic resonance imaging scans. Functional conduction slowing in the BZ was modeled by reducing sodium current density, whereas structural conduction slowing was represented by decreasing tissue conductivity and including fibrosis. The arrhythmogenic potential of APD prolongation was also tested as a basis for comparison. Within all models, the combination of reduced sodium current with structural remodeling more often degenerated into re-entry and, if so, was more likely to be sustained for more cycles. Although re-entries were also detected in experiments with prolonged APD, they were often not sustained because of the subsequent block caused by long-lasting repolarization. Functional and structural conditions associated with slow conduction rather than APD prolongation form a potent substrate for arrhythmogenesis at the isthmus/BZ of chronically infarcted hearts. Reduced excitability led to block while slow conduction shortened the wavelength of propagation, facilitating the sustenance of re-entries. These findings provide important insights for models of patient-specific risk stratification and therapy planning.


Asunto(s)
Sistema de Conducción Cardíaco/fisiopatología , Modelos Cardiovasculares , Infarto del Miocardio/fisiopatología , Potenciales de Acción , Animales , Fibrosis , Cinética , Imagen por Resonancia Magnética , Infarto del Miocardio/complicaciones , Infarto del Miocardio/diagnóstico por imagen , Infarto del Miocardio/patología , Porcinos , Taquicardia Ventricular/complicaciones
14.
J Cardiovasc Electrophysiol ; 30(10): 1894-1903, 2019 10.
Artículo en Inglés | MEDLINE | ID: mdl-31397511

RESUMEN

INTRODUCTION: Multiple cardiac magnetic resonance (CMR)-derived indices of atrial fibrillation (AF) substrate have been shown in isolation to predict long-term outcome following catheter ablation. Left atrial (LA) fibrosis, LA volume, LA ejection fraction (EF), left ventricular ejection fraction (LVEF), LA shape (sphericity) and pulmonary vein anatomy have all been shown to correlate with late AF recurrence. This study aimed to validate and assess the relative contribution of multiple indices in a long-term single-center study. METHODS AND RESULTS: Eighty-nine patients (53% paroxysmal AF, 73% male) underwent comprehensive CMR study before first-time AF ablation (median follow-up 726 days [IQR: 418-1010 days]). The 3D late gadolinium-enhanced acquisition (1.5T, 1.3 × 1.3 × 2 mm) was quantified for fibrosis; LA volume and sphericity were assessed on manual segmentation at atrial diastole; LAEF and LVEF were quantified on multislice cine imaging. AF recurred in 43 patients (48%) overall (31 at 1 year). In the recurrence group, LA fibrosis was higher (42% vs 29%; hazard ratio [HR]: 1.032; P = .002), left atrial ejection fraction (LAEF) lower (25% vs 34%; HR: 0.063; P = .016) and LVEF lower (57% vs 63%; HR: 0.011; P = .008). LA volume (135 vs 124 mL) and sphericity (0.819 vs 0.822) were similar. Multivariate Cox regression analysis was adjusted for age and sex (Model 1), additionally AF type (Model 2) and combined (Model 3). In Models 1 and 2, LA fibrosis, LAEF, and LVEF were independently associated with outcome, but only LA fibrosis was independent in Model 3 (HR: 1.021; P = .022). CONCLUSIONS: LAEF, LVEF, and LA fibrosis differed significantly in the AF recurrence cohort. However, on combined multivariate analysis only LA fibrosis remained independently associated with outcome.


Asunto(s)
Fibrilación Atrial/cirugía , Ablación por Catéter , Imagen por Resonancia Cinemagnética , Venas Pulmonares/cirugía , Potenciales de Acción , Anciano , Fibrilación Atrial/diagnóstico por imagen , Fibrilación Atrial/fisiopatología , Función del Atrio Izquierdo , Remodelación Atrial , Ablación por Catéter/efectos adversos , Femenino , Fibrosis , Frecuencia Cardíaca , Humanos , Masculino , Persona de Mediana Edad , Valor Predictivo de las Pruebas , Venas Pulmonares/diagnóstico por imagen , Venas Pulmonares/fisiopatología , Recurrencia , Reproducibilidad de los Resultados , Medición de Riesgo , Factores de Riesgo , Volumen Sistólico , Factores de Tiempo , Resultado del Tratamiento , Función Ventricular Izquierda
15.
J Cardiovasc Electrophysiol ; 30(1): 67-77, 2019 01.
Artículo en Inglés | MEDLINE | ID: mdl-30255652

RESUMEN

INTRODUCTION: The VisiTag module (CARTO3) provides an objective assessment of radiofrequency (RF) ablation parameters. This study aimed to determine the predictive value and optimal VisiTag threshold settings for prediction of gaps in mature atrial scar, as assessed non-invasively using cardiac magnetic resonance (CMR) imaging. METHODS: Twenty-four subjects (11 paroxysmal atrial fibrillation) underwent first-time RF ablation with operators blinded to VisiTag data. Three-dimensional late gadolinium enhancement (LGE) CMR scans were performed at 3 months (1.3 × 1.3 × 4 mm3 ). A survey of UK operators defined the standard VisiTag settings ("Force," 8 g; "Time," 10 seconds; "Percentage Time," 50%; "Range," 3 mm; "Impedance" and "Temperature" "off"). Each ablation procedure was exported 27 times, varying single VisiTag parameters from default values. The presence of gaps in VisiTag markers (18 sectors) was assessed for each export and compared with gaps in CMR enhancement. RESULTS: At default settings, VisiTag gaps were specific (97.5%) but less sensitive (50.4%) for CMR gaps. Sensitivity improved at higher thresholds (89.2% at 20 g, 85.6% at 30 seconds, 88.5% impedance 10 Ω, 92.8% temperature 42°C), but with a lower positive predictive value (PPV) (42.3%, 42.7%, 41.1%, and 37.7%, respectively, vs 90.9% at baseline). "Force" thresholds demonstrated stable PPV from 2 to 8 g (P = 0.24), but a rapid fall at forces more than 10 g. The binomial logistic regression model explained 41.7% of gaps; χ 2 (4), 148; P < 0.0001, correctly classifying 82% of cases (specificity 94.9%, sensitivity 56.8%). CONCLUSION: Gaps in VisiTags predict gaps in CMR LGE enhancement with high specificity at default settings. Sensitivity may be improved using more stringent thresholds but at the potential cost of unnecessary ablation, particularly when a force more than 10 g is stipulated.


Asunto(s)
Fibrilación Atrial/cirugía , Remodelación Atrial , Ablación por Catéter/efectos adversos , Cicatriz/diagnóstico por imagen , Atrios Cardíacos/cirugía , Imagen por Resonancia Magnética , Anciano , Fibrilación Atrial/diagnóstico por imagen , Fibrilación Atrial/fisiopatología , Cicatriz/etiología , Cicatriz/fisiopatología , Medios de Contraste/administración & dosificación , Femenino , Fibrosis , Atrios Cardíacos/diagnóstico por imagen , Atrios Cardíacos/fisiopatología , Humanos , Masculino , Persona de Mediana Edad , Valor Predictivo de las Pruebas , Factores de Tiempo , Resultado del Tratamiento
16.
J Cardiovasc Electrophysiol ; 30(9): 1416-1427, 2019 09.
Artículo en Inglés | MEDLINE | ID: mdl-31111557

RESUMEN

BACKGROUND: The multiple wavelets and functional re-entry hypotheses are mechanistic theories to explain atrial fibrillation (AF). If valid, a chamber's ability to support AF should depend upon the left atrial size, conduction velocity (CV), and refractoriness. Measurement of these parameters could provide a new therapeutic target for AF. We investigated the relationship between left atrial effective conducting size (LAECS ), a function of area, CV and refractoriness, and AF vulnerability in patients undergoing AF ablation. METHODS AND RESULTS: Activation mapping was performed in patients with paroxysmal (n = 21) and persistent AF (n = 18) undergoing pulmonary vein isolation. Parameters used for calculating LAECS were: (a) left atrial body area (A); (b) effective refractory period (ERP); and (c) total activation time (T). Global CV was estimated as √A/T . Effective atrial conducting size was calculated as LAECS=A/(CV×ERP) . Post ablation, AF inducibility testing was performed. The critical LAECS required for multiple wavelet termination was determined from computational modeling. LAECS was greater in patients with persistent vs paroxysmal AF (4.4 ± 2.0 cm vs 3.2 ± 1.4 cm; P = .049). AF was inducible in 14/39 patients. LAECS was greater in AF-inducible patients (4.4 ± 1.8 cm vs 3.3 ± 1.7 cm; P = .035, respectively). The difference in LAECS between inducible and noninducible patients was significant in patients with persistent (P = .0046) but not paroxysmal AF (P = .6359). Computational modeling confirmed that LAECS > 4 cm was required for continuation of AF. CONCLUSIONS: LAECS measured post ablation was associated with AF inducibility in patients with persistent, but not paroxysmal AF. These data support a role for this method in electrical substrate assessment in AF patients.


Asunto(s)
Fibrilación Atrial/cirugía , Función del Atrio Izquierdo , Ablación por Catéter , Modelos Cardiovasculares , Venas Pulmonares/cirugía , Análisis de Ondículas , Potenciales de Acción , Adulto , Anciano , Anciano de 80 o más Años , Fibrilación Atrial/diagnóstico , Fibrilación Atrial/fisiopatología , Remodelación Atrial , Ablación por Catéter/efectos adversos , Simulación por Computador , Femenino , Frecuencia Cardíaca , Humanos , Masculino , Persona de Mediana Edad , Estudios Prospectivos , Venas Pulmonares/fisiopatología , Recurrencia , Periodo Refractario Electrofisiológico , Factores de Tiempo , Resultado del Tratamiento
17.
Diabetes Obes Metab ; 21(11): 2440-2449, 2019 11.
Artículo en Inglés | MEDLINE | ID: mdl-31264767

RESUMEN

AIMS: To assess the dose-related effects of sotagliflozin, a novel dual inhibitor of sodium-glucose co-transporters-1 and -2, in type 1 diabetes (T1D). MATERIALS AND METHODS: In this 12-week, multicentre, randomized, double-blind, placebo-controlled dose-ranging trial, adults with T1D were randomized to once-daily placebo (n = 36) or sotagliflozin 75 mg (n = 35), 200 mg (n = 35) or 400 mg (n = 35). Insulin was maintained at baseline doses. The primary endpoint was least squares mean (LSM) change in glycated haemoglobin (HbA1c) from baseline. Other endpoints included proportion of participants with ≥0.5% HbA1c reduction and assessments of 2-hour postprandial glucose (PPG), weight, and urinary glucose excretion (UGE). RESULTS: From a mean baseline of 8.0% ± 0.8% (full study population), placebo-adjusted LSM HbA1c decreased by 0.3% (P = .07), 0.5% (P < .001) and 0.4% (P = .006) with sotagliflozin 75 mg, 200 mg and 400 mg, respectively, at week 12. In the placebo and sotagliflozin 75 mg, 200 mg and 400 mg groups, 33.3%, 37.1%, 80.0% and 65.7% of participants achieved an HbA1c reduction ≥0.5%. Placebo-adjusted PPG decreased by 22.2 mg/dL (P = .28), 28.7 mg/dL (P = .16) and 50.2 mg/dL (P = .013), UGE increased by 41.8 g/d (P = .006), 57.7 g/d (P < .001) and 70.5 g/d (P < .001), and weight decreased by 1.3 kg (P = .038), 2.4 kg (P < .001) and 2.6 kg (P < .001) with sotagliflozin 75 mg, 200 mg and 400 mg, respectively. One case of severe hypoglycaemia occurred in each sotagliflozin group and one case of diabetic ketoacidosis (DKA) occurred with sotagliflozin 400 mg. CONCLUSIONS: Combined with stable insulin doses, sotagliflozin 200 mg and 400 mg improved glycaemic control and weight in adults with T1D. Sotagliflozin 400 mg reduced PPG levels. UGE increased with all sotagliflozin doses. Rates of severe hypoglycaemia and DKA were low (NCT02459899).


Asunto(s)
Diabetes Mellitus Tipo 1/tratamiento farmacológico , Glicósidos/administración & dosificación , Inhibidores del Cotransportador de Sodio-Glucosa 2/administración & dosificación , Adulto , Diabetes Mellitus Tipo 1/metabolismo , Método Doble Ciego , Femenino , Hemoglobina Glucada/análisis , Glicósidos/efectos adversos , Glicósidos/uso terapéutico , Humanos , Hipoglucemia , Cetosis , Masculino , Persona de Mediana Edad , Inhibidores del Cotransportador de Sodio-Glucosa 2/efectos adversos , Inhibidores del Cotransportador de Sodio-Glucosa 2/uso terapéutico
18.
J Cardiovasc Magn Reson ; 21(1): 62, 2019 10 10.
Artículo en Inglés | MEDLINE | ID: mdl-31597563

RESUMEN

BACKGROUND: Ex-vivo cardiovascular magnetic resonance (CMR) imaging has played an important role in the validation of in-vivo CMR characterization of pathological processes. However, comparison between in-vivo and ex-vivo imaging remains challenging due to shape changes occurring between the two states, which may be non-uniform across the diseased heart. A novel two-step process to facilitate registration between ex-vivo and in-vivo CMR was developed and evaluated in a porcine model of chronic myocardial infarction (MI). METHODS: Seven weeks after ischemia-reperfusion MI, 12 swine underwent in-vivo CMR imaging with late gadolinium enhancement followed by ex-vivo CMR 1 week later. Five animals comprised the control group, in which ex-vivo imaging was undertaken without any support in the LV cavity, 7 animals comprised the experimental group, in which a two-step registration optimization process was undertaken. The first step involved a heart specific flexible 3D printed scaffold generated from in-vivo CMR, which was used to maintain left ventricular (LV) shape during ex-vivo imaging. In the second step, a non-rigid co-registration algorithm was applied to align in-vivo and ex-vivo data. Tissue dimension changes between in-vivo and ex-vivo imaging were compared between the experimental and control group. In the experimental group, tissue compartment volumes and thickness were compared between in-vivo and ex-vivo data before and after non-rigid registration. The effectiveness of the alignment was assessed quantitatively using the DICE similarity coefficient. RESULTS: LV cavity volume changed more in the control group (ratio of cavity volume between ex-vivo and in-vivo imaging in control and experimental group 0.14 vs 0.56, p < 0.0001) and there was a significantly greater change in the short axis dimensions in the control group (ratio of short axis dimensions in control and experimental group 0.38 vs 0.79, p < 0.001). In the experimental group, prior to non-rigid co-registration the LV cavity contracted isotropically in the ex-vivo condition by less than 20% in each dimension. There was a significant proportional change in tissue thickness in the healthy myocardium (change = 29 ± 21%), but not in dense scar (change = - 2 ± 2%, p = 0.034). Following the non-rigid co-registration step of the process, the DICE similarity coefficients for the myocardium, LV cavity and scar were 0.93 (±0.02), 0.89 (±0.01) and 0.77 (±0.07) respectively and the myocardial tissue and LV cavity volumes had a ratio of 1.03 and 1.00 respectively. CONCLUSIONS: The pattern of the morphological changes seen between the in-vivo and the ex-vivo LV differs between scar and healthy myocardium. A 3D printed flexible scaffold based on the in-vivo shape of the LV cavity is an effective strategy to minimize morphological changes in the ex-vivo LV. The subsequent non-rigid registration step further improved the co-registration and local comparison between in-vivo and ex-vivo data.


Asunto(s)
Imagen por Resonancia Magnética , Modelos Anatómicos , Modelos Cardiovasculares , Infarto del Miocardio/diagnóstico por imagen , Daño por Reperfusión Miocárdica/diagnóstico por imagen , Impresión Tridimensional , Animales , Enfermedad Crónica , Modelos Animales de Enfermedad , Infarto del Miocardio/patología , Infarto del Miocardio/fisiopatología , Daño por Reperfusión Miocárdica/patología , Daño por Reperfusión Miocárdica/fisiopatología , Miocardio/patología , Docilidad , Valor Predictivo de las Pruebas , Reproducibilidad de los Resultados , Sus scrofa , Función Ventricular Izquierda , Remodelación Ventricular
19.
Europace ; 21(12): 1817-1823, 2019 Dec 01.
Artículo en Inglés | MEDLINE | ID: mdl-31793653

RESUMEN

AIMS: A point-by-point workflow for pulmonary vein isolation (PVI) targeting pre-defined Ablation Index values (a composite of contact force, time, and power) and minimizing interlesion distance may optimize the creation of contiguous ablation lesions whilst minimizing scar formation. We aimed to compare ablation scar formation in patients undergoing PVI using this workflow to patients undergoing a continuous catheter drag workflow. METHODS AND RESULTS: Post-ablation cardiovascular magnetic resonance imaging was performed in patients undergoing 1st-time PVI using a parameter-guided point-by-point workflow (n = 26). Total left atrial scar burden and the width and continuity of the pulmonary vein encirclement were determined on analysis of atrial late gadolinium enhancement sequences. Comparison was made with a cohort of patients (n = 20) undergoing PVI using continuous drag lesions. Mean post-ablation scar burden and scar width were significantly lower in the point-by-point group than in the control group (6.6 ± 6.8% vs. 9.6 ± 5.0%, P = 0.03 and 7.9 ± 3.6 mm vs. 10.7 ± 2.3 mm, P = 0.003). More complete bilateral pulmonary vein encirclements were seen in the point-by-point group (P = 0.038). All patients achieved acute PVI. CONCLUSION: Pulmonary vein isolation using a point-by-point workflow is feasible and results in a lower scar burden and scar width with more complete pulmonary vein encirclements than a conventional drag lesion approach.


Asunto(s)
Fibrilación Atrial/cirugía , Ablación por Catéter , Cicatriz/diagnóstico por imagen , Angiografía por Resonancia Magnética/métodos , Venas Pulmonares/diagnóstico por imagen , Venas Pulmonares/cirugía , Técnicas de Imagen Sincronizada Cardíacas , Medios de Contraste , Femenino , Humanos , Masculino , Persona de Mediana Edad , Compuestos Organometálicos , Flujo de Trabajo
20.
Europace ; 21(6): 928-936, 2019 Jun 01.
Artículo en Inglés | MEDLINE | ID: mdl-30590509

RESUMEN

AIMS: Transvenous lead extraction (TLE) may be necessary due to system infection/erosion or lead malfunction. Cardiac resynchronization therapy (CRT) patients undergoing TLE may be at greater risk due to increased comorbidities. We examined whether patients with CRT systems undergoing TLE had more comorbidities and higher 30-day mortality than those with non-CRT devices. METHODS AND RESULTS: All TLEs between October 2000 and December 2016 were prospectively collected. During this period 925 TLEs occurred (CRT group 231, non-CRT group 694). Cardiac resynchronization therapy patients were older (68.1 ± 10.8 years vs. 64.3 ± 16.1 years, P = 0.024); more likely male (85.7% vs. 69%, P < 0.001); had lower mean left ventricular ejection fraction (34.1 ± 12.7% vs. 48.3 ± 12.9%, P < 0.001); had higher prevalence of renal impairment (33.8% vs. 13.7%, P < 0.001) and were more likely to have ≥2 comorbidities (84% vs. 40.1%, P < 0.001). Mean lead dwell time was lower in the CRT group (5.6 ± 5.5 years vs. 7.6 ± 7.1 years, P = 0.002). There was no significant difference in all-cause 30-day mortality rates between CRT (3.0%, n = 7) and non-CRT patients (2.0%, n = 14) (P = 0.443). The majority of deaths in both groups were due to sepsis. Univariate and multivariate analysis showed age, renal impairment and sepsis were associated with increased risk of 30-day mortality. Transvenous lead extraction of a CRT system did not predict 30-day mortality. CONCLUSION: Transvenous lead extraction in CRT patients was not associated with increased 30-day mortality when compared with non-CRT patients. Age, renal impairment and sepsis were independent predictors of 30-day mortality. Sepsis was the main cause of 30-day mortality.


Asunto(s)
Dispositivos de Terapia de Resincronización Cardíaca , Remoción de Dispositivos , Mortalidad/tendencias , Anciano , Causas de Muerte , Comorbilidad , Falla de Equipo , Femenino , Humanos , Masculino , Persona de Mediana Edad , Estudios Prospectivos , Factores de Riesgo
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA