Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 87
Filtrar
Más filtros

Bases de datos
País/Región como asunto
Tipo del documento
Intervalo de año de publicación
1.
Osteoarthritis Cartilage ; 31(2): 249-257, 2023 02.
Artículo en Inglés | MEDLINE | ID: mdl-36370959

RESUMEN

OBJECTIVE: To evaluate the multi-vendor multi-site reproducibility of two-dimensional (2D) multi-echo spin-echo (MESE) T2 mapping (product sequences); and to evaluate the longitudinal reproducibility of three-dimensional (3D) magnetization-prepared angle-modulated partitioned k-space spoiled gradient echo snapshots (MAPSS) T1ρ and T2 mapping (research sequences), and 2D MESE T2 mapping, separated by 6 months, in a multi-vendor multi-site setting. METHODS: Phantoms and volunteers (n = 5 from each site, n = 20 in total) were scanned on four 3 T magnetic resonance (MR) systems from four sites and three vendors (Siemens, General Electric, and Phillips). Two traveling volunteers (3 knees) scanned at all 4 sites at baseline and 6-month follow-up. Data was transferred to one site for centralized processing. Coefficients of variation (CVs) were calculated to evaluate reproducibility. RESULTS: For baseline 2D MESE T2 measures, average CV were 0.37-2.45% (intra-site) and 5.96% (inter-site) for phantoms, and 3.15-8.49% (intra-site) and 14.16% (inter-site) for volunteers. For longitudinal phantom data, intra-site CVs were 1.42-3.48% for 3D MAPSS T1ρ, 1.77-3.56% for 3D MAPSS T2, and 1.02-2.54% for 2D MESE T2. For the longitudinal volunteer data, the intra-site CVs were 2.60-4.86% for 3D MAPSS T1ρ, 3.33-7.25% for 3D MAPSS T2, and 3.11-8.77% for 2D MESE T2. CONCLUSION: This study demonstrated excellent intra-site reproducibility of 2D MESE T2 imaging, while its inter-site variation was slightly higher than 3D MAPSS T2 imaging (10.06% as previously reported). This study also showed excellent reproducibility of longitudinal T1ρ and T2 cartilage quantification, in a multi-vendor multi-site setting for both product 2D MESE T2 and 3D MAPSS T1p/T2 research sequences.


Asunto(s)
Cartílago Articular , Imagen por Resonancia Magnética , Humanos , Reproducibilidad de los Resultados , Imagen por Resonancia Magnética/métodos , Fantasmas de Imagen
2.
Osteoarthritis Cartilage ; 30(12): 1647-1657, 2022 12.
Artículo en Inglés | MEDLINE | ID: mdl-36049665

RESUMEN

OBJECTIVE: To describe the protocol of a multi-vendor, multi-site quantitative MRI study for knee post-traumatic osteoarthritis (PTOA), and to present preliminary results of cartilage degeneration using MR T1ρ and T2 imaging 10 years after anterior cruciate ligament reconstruction (ACLR). DESIGN: This study involves three sites and two MR platforms. The patients are from a nested cohort (termed as Onsite cohort) within the Multicenter Orthopaedic Outcomes Network (MOON) cohort 10 years after ACLR. Phantoms and controls were scanned for evaluating reproducibility. Cartilage was automatically segmented, and T1ρ and T2 were compared between operated, contralateral, and control knees. RESULTS: Sixty-eight ACL-reconstructed patients and 20 healthy controls were included. In phantoms, the intra-site coefficients of variation (CVs) of repeated scans ranged 1.8-2.1% for T1ρ and 1.3-1.7% for T2. The inter-site CVs ranged 1.6-2.1% for T1ρ and 1.1-1.4% for T2. In human subjects, the intra-site scan/rescan CVs ranged 2.2-3.5% for T1ρ and 2.6-4.9% for T2 for the six major compartments. In patients, operated knees showed significantly higher T1ρ and T2 values mainly in medial femoral condyle, medial tibia and trochlear cartilage compared with contralateral knees, and showed significantly higer T1ρ and T2 values in all six compartments compared to healthy control knees. The patient contralateral knees showed higher T1ρ and T2 values mainly in the lateral femoral condyle, lateral tibia, trochlear, and patellar cartilage compared to healthy control knees. CONCLUSION: A platform and workflow with rigorous quality control has been established for a multi-vendor multi-site quantitative MRI study in evaluating PTOA 10 years after ACLR. Our preliminary report suggests significant cartilage matrix changes in both operated and contralateral knees compared with healthy control knees.


Asunto(s)
Lesiones del Ligamento Cruzado Anterior , Reconstrucción del Ligamento Cruzado Anterior , Cartílago Articular , Ortopedia , Osteoartritis , Humanos , Lesiones del Ligamento Cruzado Anterior/diagnóstico por imagen , Lesiones del Ligamento Cruzado Anterior/cirugía , Cartílago Articular/diagnóstico por imagen , Cartílago Articular/cirugía , Reproducibilidad de los Resultados , Reconstrucción del Ligamento Cruzado Anterior/métodos , Articulación de la Rodilla/diagnóstico por imagen , Articulación de la Rodilla/cirugía , Imagen por Resonancia Magnética/métodos , Osteoartritis/cirugía , Estudios Multicéntricos como Asunto
3.
Osteoarthritis Cartilage ; 28(12): 1539-1550, 2020 12.
Artículo en Inglés | MEDLINE | ID: mdl-32739341

RESUMEN

OBJECTIVE: To develop 3D T1ρ and T2 imaging based on the same sequence structure on MR systems from multiple vendors, and to evaluate intra-site repeatability and inter-site inter-vendor reproducibility of T1ρ and T2 measurements of knee cartilage. METHODS: 3D magnetization-prepared angle-modulated partitioned k-space spoiled gradient echo snapshots (3D MAPSS) were implemented on MR systems from Siemens, GE and Philips. Phantom and human subject data were collected at four sites using 3T MR systems from the three vendors with harmonized protocols. Phantom data were collected by means of different positioning of the coil. Volunteers were scanned and rescanned after repositioning. Two traveling volunteers were scanned at all sites. Data were transferred to one site for centralized processing. RESULTS: Intra-site average coefficient of variations (CVs) ranged from 1.09% to 3.05% for T1ρ and 1.78-3.30% for T2 in phantoms, and 1.60-3.93% for T1ρ and 1.44-4.08% for T2 in volunteers. Inter-site average CVs were 5.23% and 6.45% for MAPSS T1ρ and T2, respectively in phantoms, and 8.14% and 10.06% for MAPSS T1ρ and T2, respectively, In volunteers. CONCLUSION: This study showed promising results of multi-site, multi-vendor reproducibility of T1ρ and T2 values in knee cartilage. These quantitative measures may be applied in large-scale multi-site, multi-vendor trials with controlled sequence structure and scan parameters and centralized data processing.


Asunto(s)
Cartílago Articular/diagnóstico por imagen , Articulación de la Rodilla/diagnóstico por imagen , Imagen por Resonancia Magnética/métodos , Humanos , Procesamiento de Imagen Asistido por Computador , Fantasmas de Imagen , Reproducibilidad de los Resultados
4.
Connect Tissue Res ; 60(6): 597-610, 2019 11.
Artículo en Inglés | MEDLINE | ID: mdl-31020864

RESUMEN

Purpose: There is a clinical need to better characterize tissue sources being used for stem cell therapies. This study focuses on comparison of cells and connective tissue progenitors (CTPs) derived from native human infrapatellar fatpad (IPFP), synovium (SYN), and periosteum (PERI). Materials and Methods: IPFP, SYN, PERI were harvested from twenty-eight patients undergoing arthroplasty. CTPs were quantitatively characterized using automated colony-forming-unit assay to compare total nucleated cell concentration-[Cell], cells/mg; prevalence-(PCTP), CTPs/million nucleated cells; CTP concentration-[CTP], CTPs/mg; proliferation and differentiation potential; and correlate outcomes with patient's age and gender. Results: [Cell] did not differ between IPFP, SYN, and PERI. PCTP was influenced by age and gender: patients >60 years, IPFP and SYN had higher PCTP than PERI (p < 0.001) and females had higher PCTP in IPFP (p < 0.001) and SYN (p = 0.001) than PERI. [CTP] was influenced by age: patients <50 years, SYN (p = 0.0165) and PERI (p < 0.001) had higher [CTP] than IPFP; patients between 60 and 69 years, SYN (p < 0.001) had higher [CTP] than PERI; patients >70 years, IPFP (p = 0.006) had higher [CTP] than PERI. In patients >60 years, proliferation potential of CTPs differed significantly (SYN>IPFP>PERI); however, differentiation potentials were comparable between all three tissue sources. Conclusion: SYN and IPFP may serve as a preferred tissue source for patients >60 years, and PERI along with SYN and IPFP may serve as a preferred tissue source for patients <60 years for cartilage repair. However, the heterogeneity among the CTPs in any given tissue source suggests performance-based selection might be useful to optimize cell-sourcing strategies to improve efficacy of cellular therapies for cartilage repair.


Asunto(s)
Tejido Adiposo/metabolismo , Condrogénesis , Rótula/metabolismo , Periostio/metabolismo , Células Madre/metabolismo , Membrana Sinovial/metabolismo , Tejido Adiposo/patología , Adulto , Anciano , Anciano de 80 o más Años , Cartílago/lesiones , Cartílago/metabolismo , Cartílago/patología , Tratamiento Basado en Trasplante de Células y Tejidos , Femenino , Humanos , Masculino , Persona de Mediana Edad , Rótula/patología , Periostio/patología , Células Madre/patología , Membrana Sinovial/patología
5.
Osteoarthritis Cartilage ; 23(4): 581-8, 2015 Apr.
Artículo en Inglés | MEDLINE | ID: mdl-25559582

RESUMEN

OBJECTIVE: To identify risk factors for radiographic signs of post-traumatic osteoarthritis (OA) 2-3 years after anterior cruciate ligament (ACL) reconstruction through multivariable analysis of minimum joint space width (mJSW) differences in a specially designed nested cohort. METHODS: A nested cohort within the Multicenter Orthopaedic Outcomes Network (MOON) cohort included 262 patients (148 females, average age 20) injured in sport who underwent ACL reconstruction in a previously uninjured knee, were 35 or younger, and did not have ACL revision or contralateral knee surgery. mJSW on semi-flexed radiographs was measured in the medial compartment using a validated computerized method. A multivariable generalized linear model was constructed to assess mJSW difference between the ACL reconstructed and contralateral control knees while adjusting for potential confounding factors. RESULTS: Unexpectedly, we found the mean mJSW was 0.35 mm wider in ACL reconstructed than in control knees (5.06 mm (95% CI 4.96-5.15 mm) vs 4.71 mm (95% CI 4.62-4.80 mm), P < 0.001). However, ACL reconstructed knees with meniscectomy had narrower mJSW compared to contralateral normal knees by 0.64 mm (95% C.I. 0.38-0.90 mm) (P < 0.001). Age (P < 0.001) and meniscus repair (P = 0.001) were also significantly associated with mJSW difference. CONCLUSION: Semi-flexed radiographs can detect differences in mJSW between ACL reconstructed and contralateral normal knees 2-3 years following ACL reconstruction, and the unexpected wider mJSW in ACL reconstructed knees may represent the earliest manifestation of post-traumatic osteoarthritis and warrants further study.


Asunto(s)
Reconstrucción del Ligamento Cruzado Anterior , Traumatismos en Atletas/cirugía , Traumatismos de la Rodilla/cirugía , Articulación de la Rodilla/diagnóstico por imagen , Meniscos Tibiales/cirugía , Adolescente , Adulto , Factores de Edad , Traumatismos en Atletas/complicaciones , Niño , Estudios de Cohortes , Femenino , Estudios de Seguimiento , Humanos , Traumatismos de la Rodilla/complicaciones , Articulación de la Rodilla/cirugía , Modelos Lineales , Estudios Longitudinales , Masculino , Meniscos Tibiales/diagnóstico por imagen , Osteoartritis de la Rodilla/epidemiología , Radiografía , Factores de Riesgo , Resultado del Tratamiento , Adulto Joven
6.
Clin Radiol ; 69(12): e538-44, 2014 Dec.
Artículo en Inglés | MEDLINE | ID: mdl-25291959

RESUMEN

AIM: To compare radiation dose surrogates [volume CT dose index (CTDIvol), dose-length product (DLP), size-specific dose estimate (SSDE), and effective dose] and image noise in a cohort of patients undergoing hepatocellular carcinoma screening who underwent both single-energy CT (SECT) and dual-energy CT (DECT). MATERIALS AND METHODS: In this institutional review board-approved, Health Insurance Portability and Accountability Act-compliant retrospective study, 74 adults (mean age 59.5 years) underwent 64 section SECT (120 kVp and weight-based reference mAs) and 128 section dual-source DECT (100/Sn 140 kVp and CTDIvol, adjusted to match the CDTIvol of the SECT protocol) on different occasions. Noise levels were measured in the liver, inferior vena cava (IVC), retroperitoneal (RP) fat, and aorta. Generalized linear models were constructed to compare dose and noise, adjusting for effective diameter. RESULTS: The total DLP (1371.11 mGy-cm, SD = 527.91) and effective dose (20.57 mSv, SD = 7.92) with SECT were significantly higher than the DLP (864.84 mGy-cm, SD = 322.10) and effective dose (12.97 mSv, SD = 4.83) with DECT (p < 0.001). The differences between SECT and DECT increased as the patient's effective diameter increased (p < 0.001). Noise levels in the liver (22.4 versus 21.9 HU), IVC (22.3 versus 23.4 HU), and RP fat (23.5 versus 23 HU) were similar for DECT and SECT (p > 0.05) but were significantly lower in the aorta for DECT (25.3 versus 26.4 HU; p = 0.006). CONCLUSION: DECT imaging of the abdomen can achieve noise levels comparable to those seen with SECT imaging without a dose penalty to patients.


Asunto(s)
Carcinoma Hepatocelular/diagnóstico por imagen , Neoplasias Hepáticas/diagnóstico por imagen , Dosis de Radiación , Interpretación de Imagen Radiográfica Asistida por Computador/métodos , Tomografía Computarizada por Rayos X/métodos , Adulto , Anciano , Carga Corporal (Radioterapia) , Estudios de Cohortes , Femenino , Humanos , Procesamiento de Imagen Asistido por Computador/métodos , Masculino , Persona de Mediana Edad
7.
AJNR Am J Neuroradiol ; 41(4): 591-597, 2020 04.
Artículo en Inglés | MEDLINE | ID: mdl-32217554

RESUMEN

BACKGROUND AND PURPOSE: NeuroQuant is an FDA-approved software that performs automated MR imaging quantitative volumetric analysis. This study aimed to compare the accuracy of NeuroQuant analysis with visual MR imaging analysis by neuroradiologists with expertise in epilepsy in identifying hippocampal sclerosis. MATERIALS AND METHODS: We reviewed 144 adult patients who underwent presurgical evaluation for temporal lobe epilepsy. The reference standard for hippocampal sclerosis was defined by having hippocampal sclerosis on pathology (n = 61) or not having hippocampal sclerosis on pathology (n = 83). Sensitivities, specificities, positive predictive values, and negative predictive values were compared between NeuroQuant analysis and visual MR imaging analysis by using a McNemar paired test of proportions and the Bayes theorem. RESULTS: NeuroQuant analysis had a similar specificity to neuroradiologist visual MR imaging analysis (90.4% versus 91.6%; P = .99) but a lower sensitivity (69.0% versus 93.0%, P < .001). The positive predictive value of NeuroQuant analysis was comparable with visual MR imaging analysis (84.0% versus 89.1%), whereas the negative predictive value was not comparable (79.8% versus 95.0%). CONCLUSIONS: Visual MR imaging analysis by a neuroradiologist with expertise in epilepsy had a higher sensitivity than did NeuroQuant analysis, likely due to the inability of NeuroQuant to evaluate changes in hippocampal T2 signal or architecture. Given that there was no significant difference in specificity between NeuroQuant analysis and visual MR imaging analysis, NeuroQuant can be a valuable tool when the results are positive, particularly in centers that lack neuroradiologists with expertise in epilepsy, to help identify and refer candidates for temporal lobe epilepsy resection. In contrast, a negative test could justify a case referral for further evaluation to ensure that false-negatives are detected.


Asunto(s)
Epilepsia del Lóbulo Temporal/diagnóstico por imagen , Hipocampo/diagnóstico por imagen , Interpretación de Imagen Asistida por Computador/métodos , Imagen por Resonancia Magnética/métodos , Neuroimagen/métodos , Programas Informáticos , Adulto , Teorema de Bayes , Epilepsia del Lóbulo Temporal/patología , Femenino , Hipocampo/patología , Humanos , Masculino , Persona de Mediana Edad , Radiólogos , Esclerosis/diagnóstico por imagen , Esclerosis/patología , Sensibilidad y Especificidad
8.
J Bone Joint Surg Am ; 100(20): 1771-1780, 2018 Oct 17.
Artículo en Inglés | MEDLINE | ID: mdl-30334888

RESUMEN

BACKGROUND: Current decisions on cellular therapies for osteoarthritis are based primarily on clinical experience or on assumptions about preferred cell sourcing. They have not been informed by rigorous standardized measurements of the chondrogenic connective-tissue progenitors (CTP-Cs) or their intrinsic diversity of chondrogenic potential. The goal of this study was to quantitatively define the CTP-Cs resident in cartilage of different grades of osteoarthritis and to compare their concentration, prevalence, and biological potential. METHODS: Twenty-three patients who had varus malalignment of the knee and were scheduled to undergo elective total knee arthroplasty for idiopathic osteoarthritis and who had grade 1-2 osteoarthritis on the lateral femoral condyle and grade 3-4 osteoarthritis on the medial femoral condyle were recruited for study of the cartilage removed during surgery. CTP-Cs were assayed by a standardized colony-forming-unit assay using automated image-analysis software based on ASTM standard test method F2944-12. RESULTS: Cell concentration was significantly greater (p < 0.001) in grade 3-4 cartilage than in grade 1-2 cartilage. The prevalence of CTP-Cs varied widely, but it trended lower in grade 3-4 cartilage than in grade 1-2 samples (p = 0.078). The biological performance of CTP-Cs from grade 1-2 and grade 3-4 cartilage was comparable. Increased cell concentration was a significant predictor of decreased CTP-C prevalence (p = 0.002). CONCLUSIONS: Although grade 3-4 cartilage showed fewer CTP-Cs than grade 1-2 cartilage, the range of biological performance was comparable, which suggests that either may be used as a source for potent CTP-Cs. However, the biological reason for the heterogeneity of CTP-Cs in cartilage and the biological implications of that heterogeneity are not well understood and require further study. CLINICAL RELEVANCE: In order to improve the efficacy of cartilage cell therapy procedures, it is key to characterize the quality and quantity of the cells and progenitors being administered. Additionally, understanding the heterogeneity in order to select appropriate subsets of populations will improve the rigor of decisions concerning cell sourcing and targeting for pharmacological and cellular therapies.


Asunto(s)
Cartílago Articular/citología , Osteoartritis de la Rodilla/patología , Células Madre/citología , Adulto , Anciano , Tratamiento Basado en Trasplante de Células y Tejidos , Células Cultivadas , Progresión de la Enfermedad , Femenino , Humanos , Articulación de la Rodilla , Masculino , Persona de Mediana Edad
9.
Curr Res Transl Med ; 65(4): 133-139, 2017 11.
Artículo en Inglés | MEDLINE | ID: mdl-29132902

RESUMEN

OBJECTIVE: The two main objectives of the study include (1) Test the hypothesis that the lateral femoral condyle (LFC) in patients with primary OA and varus knees undergoing total knee arthroplasty (TKA) can be used as a model to better characterize varying histological features of human OA, (2) Correlate characteristic OA features using the established histopathological scoring systems (HHGS and OARSI) to understand potential histopathological patterns of OA initiation. DESIGN: Two osteochondral specimens (4×4×8mm) were collected from fifty patient's LFC at the time of TKA (total 100 specimens), who presented preserved lateral knee compartment with joint space width>2mm. Three independent readers graded the sections on three different occasions using HHGS and OARSI systems. The correlation between individual parameters of the two scoring systems and their inter- and intra-reader variability, reliability and reproducibility were estimated. RESULTS: All samples in this cohort showed abnormal histopathological features. Total histopathological scores of the LFC ranged from HHGS median=4.6 (range=0 to 11), and OARSI median=5.2 (range=0 to 19.5). The four individual sub-items of HHGS scoring system (structure, cells, safraninO staining, tidemark) were weakly correlated, with the correlation between structure and cellularity being the strongest (r=0.40). Both the scoring systems had similar repeatability and reproducibility coefficients of<21%. CONCLUSIONS: OA changes in the LFC are not confined to any one region, and maybe seen in different regions of cartilage, tidemark, subchondral bone, and/or the marrow space vascularity. These variations may point to the possibility of several potential patterns of initiation in OA.


Asunto(s)
Cartílago Articular/patología , Articulación de la Rodilla/patología , Osteoartritis de la Rodilla/patología , Adulto , Anciano , Anciano de 80 o más Años , Estudios de Cohortes , Progresión de la Enfermedad , Femenino , Fémur/patología , Técnicas Histológicas , Humanos , Masculino , Persona de Mediana Edad
10.
J Nucl Med ; 37(11): 1809-15, 1996 Nov.
Artículo en Inglés | MEDLINE | ID: mdl-8917180

RESUMEN

UNLABELLED: Preoperative localization of hyperfunctioning parathyroid tissue in patients with primary hyperparathyroidism has been a longstanding diagnostic challenge. This study directly compared FDG-PET and sestamibi-SPECT for preoperative detection of abnormal parathyroid tissue. METHODS: Twenty-one consecutive patients with primary hyperparathyroidism were studied prospectively before surgical neck exploration. SPECT of the neck and chest was performed at 15 min and 2 hr after intravenous 99mTc-sestamibi. Regional body PET was performed 45 min after intravenous FDG. RESULTS: Surgery revealed 19 solitary parathyroid adenomas, 2 parathyroid adenomas in one patient; and 3 hyperplastic parathyroid glands in one patient, and 51 normal parathyroid glands. The diagnostic sensitivities for detection of parathyroid adenomas of 43% (9 of 21) for dual-phase sestamibi-SPECT and 86% (18 of 21) for FDG-PET were significantly different (p < 0.001). The difference in diagnostic specificities of 78% (40 of 51) for FDG-PET and 90% (46 of 51) for dual-phase sestamibi-SPECT approached statistical significance (p = 0.063). CONCLUSION: This study demonstrates that FDG-PET is more sensitive than sestamibi-SPECT in the preoperative localization of parathyroid adenomas in patients with primary hyperparathyroidism.


Asunto(s)
Desoxiglucosa/análogos & derivados , Radioisótopos de Flúor , Hiperparatiroidismo/diagnóstico por imagen , Tecnecio Tc 99m Sestamibi , Tomografía Computarizada de Emisión de Fotón Único , Tomografía Computarizada de Emisión , Adenoma/diagnóstico por imagen , Adulto , Anciano , Anciano de 80 o más Años , Femenino , Fluorodesoxiglucosa F18 , Humanos , Hiperparatiroidismo/cirugía , Hiperplasia , Masculino , Persona de Mediana Edad , Glándulas Paratiroides/diagnóstico por imagen , Glándulas Paratiroides/patología , Neoplasias de las Paratiroides/diagnóstico por imagen , Estudios Prospectivos , Sensibilidad y Especificidad
11.
J Thorac Cardiovasc Surg ; 115(1): 45-50; discussion 50-2, 1998 Jan.
Artículo en Inglés | MEDLINE | ID: mdl-9451044

RESUMEN

PURPOSE: Daily portable chest radiographs are routinely ordered in many institutions after thoracic surgery. Our purpose was to assess the efficacy and cost of this practice and to determine the optimum use of postoperative x-ray studies. METHODS: A prospective review of all portable chest x-ray films after 100 consecutive elective thoracotomies (DRG 75) was conducted. Each x-ray study initiated a three-part survey. First, the surgeon listed whether the x-ray study was routine and the anticipated management had it not been available. The radiologist then interpreted and scored the x-ray study as follows: negative, expected findings; A, minor findings necessitating no intervention; B, minor findings necessitating intervention; or C, major findings necessitating intervention. Finally, the x-ray film and the interpretation were returned to the surgeon. Any interventions necessitated by the x-ray study were recorded. RESULTS: In 6 months, 99 patients underwent 82 pulmonary resections and 18 other major procedures. In the postoperative period, 769 portable chest x-ray studies were ordered, median five per patient (range 2 to 49). Of these, 731 (95%) were routine and 38 (5%), nonroutine. Severity scores were as follows: negative in 106 (13.8%), A in 558 (72.5%), B in 59 (7.7%), and C in 46 (6.0%). X-ray findings altered management in 43 of 769 studies (5.6%): in 33 routine (4.5%), in 10 nonroutine (26.3%), in 13 A (2.3%), in 22 B (37.3%), and in 8 C (17.4%). CONCLUSIONS: These results demonstrate that routine daily portable chest x-ray studies have a minimal impact on management. It is, in fact, nonroutine x-ray studies that more often alter management. Had routine portable chest x-ray studies, which cost $114 each in our institution, been limited to one immediately after the operation, only 133 such studies (100 routine and 33 nonroutine) would have been needed in the care of these patients. Elimination of 636 (82.7%) x-ray studies reduces the cost of care by $725 per patient ($286,000 annually). For major thoracic procedures, it is safe, efficacious, and cost effective to eliminate routine postoperative portable chest x-ray studies and order nonroutine portable studies only when clinically indicated.


Asunto(s)
Radiografía Torácica/estadística & datos numéricos , Toracotomía , Adulto , Anciano , Anciano de 80 o más Años , Ahorro de Costo , Análisis Costo-Beneficio , Procedimientos Quirúrgicos Electivos , Femenino , Humanos , Masculino , Persona de Mediana Edad , Sistemas de Atención de Punto/economía , Sistemas de Atención de Punto/estadística & datos numéricos , Cuidados Posoperatorios/economía , Cuidados Posoperatorios/métodos , Complicaciones Posoperatorias/diagnóstico por imagen , Complicaciones Posoperatorias/terapia , Estudios Prospectivos , Radiografía Torácica/economía , Radiografía Torácica/instrumentación , Toracotomía/economía
12.
Invest Radiol ; 29(2): 238-43, 1994 Feb.
Artículo en Inglés | MEDLINE | ID: mdl-8169102

RESUMEN

RATIONALE AND OBJECTIVES: Hanley and McNeil (1982) proposed a nonparametric method for computing the standard error of the area under the receiver operating characteristic (ROC) curve. The method has been important in planning the minimum sample size for ROC studies. However, the validity of this method for rating data with various standard deviation ratios has not been investigated. METHODS: A simulation study was conducted to compare the empirical standard error of the area under the curve with Hanley and McNeil's estimate over a range of parameters. An alternative method of computing the standard error based on a binormal distribution is proposed. RESULTS: The method of Hanley and McNeil can lead to underestimation of the minimum sample size. The proposed method provides more appropriate estimates of sample size. CONCLUSIONS: When determining sample size for a study of the area under the ROC curve where rating data are used, the standard error estimator based on the binormal distribution should be used.


Asunto(s)
Curva ROC , Matemática , Radiología
13.
Invest Radiol ; 25(7): 835-7, 1990 Jul.
Artículo en Inglés | MEDLINE | ID: mdl-2391200

RESUMEN

Maximum likelihood estimation, assuming a binormal model, has been used extensively to estimate the area under receiver operating characteristic (ROC) curves and thus provide an index of diagnostic accuracy for the comparison of two imaging systems. However, in some instances, a degenerate data set results in a fitted ROC curve of inappropriate shape. In those instances, a nonparametric Wilcoxon statistic may be used to compare the areas under two ROC curves. Simulation of this approach indicates that the procedure has relatively high statistical power and its use in specific degenerate data sets shows its applications potential.


Asunto(s)
Interpretación Estadística de Datos , Diagnóstico por Imagen/estadística & datos numéricos , Curva ROC , Humanos
14.
Invest Radiol ; 25(3): 225-9, 1990 Mar.
Artículo en Inglés | MEDLINE | ID: mdl-2332307

RESUMEN

ROC methodology has been expanded in recent years to include multi-disease experiments. To accommodate these changes, different rating formats, general or disease specific, can be used. No experimental data are available concerning the possible effects of the rating format on the results of these studies. We performed a multi-observer, multi-disease study in which 196 chest images were rated using a format where each disease was evaluated individually and one in which the cases were evaluated without scoring a specific disease. The results indicate that for our data set, the overall assessment of accuracy was not significantly affected by the study format used. Thus, in spite of the difficulties in selecting appropriate controls and the necessity of reassessing sample size considerations, the disease-specific format appears to produce an assessment of accuracy equivalent to that produced by the general format. This equivalence permits the use of the disease-specific approach since it more closely simulates the readers' true environment and is more appropriate for comparing imaging systems that may have a relative accuracy that is disease specific.


Asunto(s)
Enfermedades Pulmonares/diagnóstico por imagen , Curva ROC , Diagnóstico Diferencial , Humanos , Neumotórax/diagnóstico por imagen , Fibrosis Pulmonar/diagnóstico por imagen , Radiografía , Encuestas y Cuestionarios
15.
Invest Radiol ; 25(3): 230-4, 1990 Mar.
Artículo en Inglés | MEDLINE | ID: mdl-2332308

RESUMEN

Receiver-operating characteristic (ROC) analysis has been used in many medical imaging applications during the past decade. In order to ensure that reader-confidence ratings are analyzable (well distributed to meet convergence requirements of curve-fitting algorithms) and meaningful (limit extrapolation of the data), many investigators train readers specifically for this purpose. No experimental data are available concerning the possible effects of such training on the results of ROC studies. We performed a multi-observer, multi-disease study in which 300 chest images were rated by four radiologists before and after they were trained to provide well-distributed confidence ratings. The results indicate that for our data set, reader and disease-specific accuracy was not significantly affected by the training process for interstitial disease and pneumothoraces. However, the accuracy of two readers was significantly affected for the detection of nodules (P less than 0.05), and the overall accuracy of one reader was significantly affected for the classification of normal versus abnormal images (P less than 0.01). Thus, in spite of the difficulties associated with the performance of ROC studies in a free-reading environment, one should carefully consider the possible effects of any intervention on the results prior to conducting ROC studies.


Asunto(s)
Enfermedades Pulmonares/diagnóstico por imagen , Variaciones Dependientes del Observador , Curva ROC , Enseñanza , Humanos , Neumotórax/diagnóstico por imagen , Fibrosis Pulmonar/diagnóstico por imagen , Intensificación de Imagen Radiográfica , Enseñanza/métodos
16.
AJNR Am J Neuroradiol ; 19(1): 183-6, 1998 Jan.
Artículo en Inglés | MEDLINE | ID: mdl-9432177

RESUMEN

PURPOSE: We documented the morphological changes on enhanced MR imaging studies that occur in epidural scar over a period of 1 year after lumbar diskectomy. METHODS: The study population was culled from a randomized, multicenter clinical trial designed to evaluate the efficacy of a device inhibiting postoperative epidural fibrosis after single-level, unilateral laminectomy/diskectomy for herniated lumbar disk. Analysis was restricted to 71 control subjects who did not receive the device. All patients underwent surgery after receiving clinical and MR examinations, with follow-up MR studies at 6 and 12 months. Evaluation of all MR images was performed by one interpreter, who was blinded to treatment arm and clinical findings. The extent of epidural scar seen at the 6- and 12-month MR examinations was graded on a scale of 0 to 4 for each quadrant at each imaging section encompassing the surgical level. RESULTS: Eighty-five percent of the patients had no change in the amount of anterior epidural scar between the 6- and 12-month MR examinations; 75% of the patients showed no change in the amount of posterior epidural scar between the 6- and 12-month examinations. CONCLUSION: The majority of our patients had no change in the amount of epidural scarring visible at enhanced MR imaging over a 1-year period after lumbar laminectomy/diskectomy.


Asunto(s)
Cicatriz/patología , Desplazamiento del Disco Intervertebral/cirugía , Vértebras Lumbares/patología , Imagen por Resonancia Magnética , Cicatriz/cirugía , Discectomía , Espacio Epidural , Fibrosis/prevención & control , Humanos , Laminectomía , Vértebras Lumbares/cirugía , Complicaciones Posoperatorias/prevención & control , Factores de Tiempo
17.
AJNR Am J Neuroradiol ; 20(3): 461-6, 1999 Mar.
Artículo en Inglés | MEDLINE | ID: mdl-10219412

RESUMEN

BACKGROUND AND PURPOSE: There is a wide range of normal variation is sphenoid sinus development, especially in the size of the lateral recesses. The purpose of this study was to determine imaging characteristics that may help differentiate between opacification of a developmentally asymmetric lateral recess and a true expansile lesion of the sphenoid sinus. METHODS: Coronal CT was performed in seven patients with expansile or erosive benign lesions of the sphenoid sinus, and results were compared to a control population of 72 subjects with unopacified sphenoid sinuses. The degree of asymmetry of lateral recess development was assessed with particular attention to the separation of vidian's canal and the foramen rotundum (vidian-rotundum distance). The images were also examined for evidence of: erosion, defined as loss of the normal thin bony margin on at least two contiguous sections; apparent thinning of the sinus wall, defined as a focal apparent decrease in thickness again on at least two contiguous sections; and for vidian's canal or foramen rotundum rim erosion or flattening. RESULTS: Of the seven patients with expansile lesions, vidian's canal margin erosion was present in seven, unequivocal sinus expansion in three, wall erosion in three, wall thinning in three, erosion of the foramen rotundum in two, and flattening in the foramen rotundum in four. Forty-one of the 72 controls had lateral recess formation, 28 of which were asymmetric. The distance between vidian's canal and the foramen rotundum (vidian-rotundum distance) relied on the presence or absence of pneumatization, with a significantly larger distance in the presence of greater wing pneumatization. Examination of 24 controls revealed apparent thinning of the sinus wall, typically at the carotid groove, but no flattening, thinning, or erosion of the vidian canal or of the foramen rotundum. CONCLUSION: Examination of controls and patients with expansile or erosive lesions of the sphenoid sinus revealed side-to-side asymmetry in the development of the sinus and lateral recess, making subtle expansion difficult to assess. Furthermore, variability in the vidian-rotundum distance correlated with degree of pneumatization, and did not necessarily reflect expansion. Thus, in the absence of gross sinus wall erosion, flattening or erosion of the rims of vidian's canal or the foramen rotundum provides the most specific evidence of an expansile or erosive process within the sinus.


Asunto(s)
Enfermedades de los Senos Paranasales/diagnóstico por imagen , Seno Esfenoidal/diagnóstico por imagen , Adolescente , Adulto , Cefalometría , Niño , Estudios de Cohortes , Diagnóstico Diferencial , Femenino , Humanos , Masculino , Persona de Mediana Edad , Mucocele/diagnóstico por imagen , Neoplasias de los Senos Paranasales/diagnóstico por imagen , Pólipos/diagnóstico por imagen , Seno Esfenoidal/patología , Tomografía Computarizada por Rayos X
18.
AJNR Am J Neuroradiol ; 18(7): 1339-47, 1997 Aug.
Artículo en Inglés | MEDLINE | ID: mdl-9282867

RESUMEN

PURPOSE: To implement and assess the application of segmented three-dimensional echo-planar MR imaging time-of-flight flow sequences for studying the anatomy of the cervical carotid arteries at 1.5 T. METHODS: The 3-D echo-planar sequences were segmented along the in-plane phase-encoding direction. Echo train lengths (ETLs) of 3 and 5 and signal bandwidths of +/-25, +/-33, and +/-50 KHz were tested along with a conventional (ETL = 1) 3-D MR flow study in six healthy volunteers and in five patients with known arteriosclerotic disease involving the carotid bifurcation as confirmed by conventional angiography. The volunteer data were used to rank the techniques with respect to vessel dimension, vessel/background contrast, and quality by four trained neuroradiologists. For the patient studies, the percentage of stenoses was measured for all MR studies and compared against the conventional angiographic data using the criteria of the North American Symptomatic Carotid Endarterectomy Trial. RESULTS: Using Wilcoxon's test statistic and a significance level of .05, we found that the conventional MR flow examination was better than the segmented techniques and that the segmented techniques with ETL of 3 were superior to their counterparts with ETL of 5. For the ETL of 3 techniques, the high-bandwidth studies were inferior to their lower bandwidth counterparts; however, there was no significant difference between the performance of the medium- and low-bandwidth sequences. The patient data revealed that the segmented techniques consistently overestimated the severity of stenosis; however, in no instance did any of the segmented examinations erroneously indicate the presence of disease. CONCLUSIONS: The reduction in acquisition time and the zero false-positive rate we obtained suggest that segmented 3-D echo-planar MR flow techniques may be used as a screening/locating study for cervical carotid artery disease.


Asunto(s)
Arterias Carótidas/anatomía & histología , Imagen Eco-Planar/instrumentación , Procesamiento de Imagen Asistido por Computador/instrumentación , Angiografía por Resonancia Magnética/instrumentación , Adulto , Anciano , Arteriosclerosis/diagnóstico , Velocidad del Flujo Sanguíneo/fisiología , Enfermedades de las Arterias Carótidas/diagnóstico , Estenosis Carotídea/diagnóstico , Femenino , Humanos , Aumento de la Imagen/instrumentación , Masculino , Persona de Mediana Edad , Variaciones Dependientes del Observador , Valores de Referencia
19.
AJNR Am J Neuroradiol ; 14(5): 1215-23, 1993.
Artículo en Inglés | MEDLINE | ID: mdl-8237706

RESUMEN

PURPOSE: To compare conventional T2-weighted spin-echo imaging with a rapid acquisition relaxation enhanced (RARE) technique in the routine evaluation of lumbar degenerative disk disease. METHODS: Thirty consecutive patients referred for evaluation of the lumbar spine for suspected degenerative disk disease were evaluated with sagittal and axial T1-weighted spin-echo, conventional T2-weighted spin-echo, and T2-weighted RARE "turbo spin-echo" sequences (4000/93/2 (repetition time/echo time/excitations), 192 x 256, echo train length of 8). Conventional T2-weighted and RARE images were evaluated independently by two neuroradiologists for image quality, presence of artifacts, cerebrospinal fluid signal intensity, extradural interface conspicuity, intradural nerve root conspicuity, soft-tissue detail, and signal intensity of normal and degenerated intervertebral disks. RESULTS: Both readers rated the cerebrospinal fluid signal higher, the extradural interface conspicuity higher, and the nerve root detail greater on the turbo spin-echo than on conventional spin-echo images. Neither reader had a significant difference in ranking "normal" or "degenerated" disk signal on the two sequences. Both readers rated soft-tissue detail higher for conventional than for turbo spin-echo. CONCLUSION: RARE sequences can replace conventional T2-weighted spin-echo sagittal studies for degenerative lumbar disk disease.


Asunto(s)
Disco Intervertebral , Imagen por Resonancia Magnética/métodos , Enfermedades de la Columna Vertebral/diagnóstico , Artefactos , Humanos , Desplazamiento del Disco Intervertebral/diagnóstico , Estudios Prospectivos , Estenosis Espinal/diagnóstico , Espondilolistesis/diagnóstico
20.
AJNR Am J Neuroradiol ; 15(7): 1351-7, 1994 Aug.
Artículo en Inglés | MEDLINE | ID: mdl-7976949

RESUMEN

PURPOSE: To determine whether fast spin-echo sequences could replace conventional spin-echo methods in the evaluation of head and neck neoplasms and associated adenopathy and to evaluate differences in tissue contrast characteristics between conventional spin-echo and fast spin-echo examinations of head and neck disease. METHODS: Twenty-seven patients with squamous cell carcinoma were imaged on a 1.5-T imager with both conventional spin-echo and fast spin-echo sequences with identical section thickness and position. Twenty-one of the 27 fast spin-echo studies were performed with frequency-selective fat suppression. Three radiologists independently evaluated the images using a five-point scale to compare primary lesion margin definition and conspicuity, lymph node margin definition and conspicuity, gross motion artifact, and flow artifact. Quantitative percent contrast and contrast-to-noise ratios were calculated and compared in 7 cases with fat-suppressed fast spin-echo. RESULTS: Fast spin-echo was preferred by all three readers for lesion margin conspicuity and lymph node conspicuity. Gross motion and flow artifact demonstrated trends toward reader preference for fast spin-echo. Quantitative contrast values for fast spin-echo were significantly greater than those for conventional spin-echo. CONCLUSIONS: Fast spin-echo with fat suppression can replace conventional spin-echo at a time savings of more than 50% and improves tissue contrast and the conspicuity and definition of margins for primary lesions and lymph nodes. Fat-suppression heterogeneity remains the major limitation of this technique. Thus, careful attention to fat-suppression failure and unwanted water saturation is essential.


Asunto(s)
Carcinoma de Células Escamosas/diagnóstico , Neoplasias de Cabeza y Cuello/diagnóstico , Aumento de la Imagen/métodos , Imagen por Resonancia Magnética/métodos , Tejido Adiposo/patología , Artefactos , Carcinoma de Células Escamosas/patología , Neoplasias de Cabeza y Cuello/patología , Humanos , Neoplasias Hipofaríngeas/diagnóstico , Neoplasias Hipofaríngeas/patología , Ganglios Linfáticos/patología , Metástasis Linfática , Neoplasias de la Boca/diagnóstico , Neoplasias de la Boca/patología , Neoplasias Orofaríngeas/diagnóstico , Neoplasias Orofaríngeas/patología
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA