Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 66
Filtrar
Más filtros

Bases de datos
País/Región como asunto
Tipo del documento
Intervalo de año de publicación
1.
Circ J ; 88(4): 519-527, 2024 03 25.
Artículo en Inglés | MEDLINE | ID: mdl-38325820

RESUMEN

BACKGROUND: We investigated the efficacy of left ventricular (LV) myocardial damage by native T1mapping obtained with cardiac magnetic resonance (CMR) for patients undergoing transcatheter edge-to-edge repair (TEER). METHODS AND RESULTS: We studied 40 symptomatic non-ischemic heart failure (HF) patients and ventricular functional mitral regurgitation (VFMR) undergoing TEER. LV myocardial damage was defined as the native T1Z-score, which was converted from native T1values obtained with CMR. The primary endpoint was defined as HF rehospitalization or cardiovascular death over 12 months after TEER. Multivariable Cox proportional hazards analysis showed that the native T1Z-score was the only independent parameter associated with cardiovascular events (hazard ratio 3.40; 95% confidential interval 1.51-7.67), and that patients with native T1Z-scores <2.41 experienced significantly fewer cardiovascular events than those with native T1Z-scores ≥2.41 (P=0.001). Moreover, the combination of a native T1Z-score <2.41 and more severe VFMR (effective regurgitant orifice area [EROA] ≥0.30 cm2) was associated with fewer cardiovascular events than a native T1Z-score ≥2.41 and less severe VFMR (EROA <0.30 cm2; P=0.002). CONCLUSIONS: Assessment of baseline LV myocardial damage based on native T1Z-scores obtained with CMR without gadolinium-based contrast media is a valuable additional parameter for better management of HF patients and VFMR following TEER.


Asunto(s)
Cardiomiopatías , Insuficiencia Cardíaca , Implantación de Prótesis de Válvulas Cardíacas , Insuficiencia de la Válvula Mitral , Humanos , Insuficiencia de la Válvula Mitral/diagnóstico por imagen , Insuficiencia de la Válvula Mitral/cirugía , Ventrículos Cardíacos , Corazón , Medios de Contraste , Cardiomiopatías/diagnóstico por imagen , Resultado del Tratamiento
2.
Echocardiography ; 41(1): e15735, 2024 Jan.
Artículo en Inglés | MEDLINE | ID: mdl-38284671

RESUMEN

OBJECTIVES: We previously reported a higher left atrial volume index (LAVI) was independently associated with left atrial (LA) appendage (LAA) thrombus formation in 737 patients with non-valvular atrial fibrillation (NVAF) receiving appropriate oral anticoagulation therapy. Since our previous study was a retrospective single-center study, we designed and conducted a prospective multi-center study to verify our findings for LAVI as a predictor of LAA thrombus in patients with NVAF receiving appropriate oral anticoagulation therapy. METHODS: This prospective multi-center study comprised 746 consecutive patients with NVAF recruited between December 2021 and March 2023 from eight institutions in Japan, who were receiving appropriate oral anticoagulation therapy, had undergone transthoracic echocardiography and transesophageal echocardiography (TEE). RESULTS: LAA thrombi were observed in 21 patients (2.8%). The prevalence of LAA thrombus formation in patients with paroxysmal AF (PAF) was significantly lower than that in patients with non-PAF (0.7% vs. 4.1%, p = .006). LAA thrombus formation was detected in none (0/171) of the patients with normal size LA (LAVI ≤ 34 mL/m2 ). The prevalence of LAA thrombus formation in patients with mildly dilated LA (LAVI: 34-49.9 mL/m2 ) was 2.1% (6/283), but that in PAF patients was low at 1.0% (1/104). Furthermore, this prevalence in patients with severely dilated LA (LAVI ≥ 50 mL/m2 ) was high at 5.1% (15/292). CONCLUSIONS: The findings of this prospective multi-center study are consistent with those of our previous study. Thus, the need for TEE prior to catheter ablation or electrical cardioversion can be determined by the level of LAVI.


Asunto(s)
Apéndice Atrial , Fibrilación Atrial , Cardiopatías , Trombosis , Humanos , Apéndice Atrial/diagnóstico por imagen , Fibrilación Atrial/complicaciones , Fibrilación Atrial/tratamiento farmacológico , Fibrilación Atrial/epidemiología , Estudios Retrospectivos , Estudios Prospectivos , Atrios Cardíacos/diagnóstico por imagen , Ecocardiografía Transesofágica , Trombosis/complicaciones , Anticoagulantes/uso terapéutico
3.
Cardiovasc Diabetol ; 15(1): 121, 2016 08 26.
Artículo en Inglés | MEDLINE | ID: mdl-27565734

RESUMEN

BACKGROUND: Recent experimental studies have revealed that n-3 fatty acids, such as eicosapentaenoic acid (EPA) regulate postprandial insulin secretion, and correct postprandial glucose and lipid abnormalities. However, the effects of 6-month EPA treatment on postprandial hyperglycemia and hyperlipidemia, insulin secretion, and concomitant endothelial dysfunction remain unknown in patients with impaired glucose metabolism (IGM) and coronary artery disease (CAD). METHODS AND RESULTS: We randomized 107 newly diagnosed IGM patients with CAD to receive either 1800 mg/day of EPA (EPA group, n = 53) or no EPA (n = 54). Cookie meal testing (carbohydrates: 75 g, fat: 28.5 g) and endothelial function testing using fasting-state flow-mediated dilatation (FMD) were performed before and after 6 months of treatment. The primary outcome of this study was changes in postprandial glycemic and triglyceridemic control and secondary outcomes were improvement of insulin secretion and endothelial dysfunction. After 6 months, the EPA group exhibited significant improvements in EPA/arachidonic acid, fasting triglyceride (TG), and high-density lipoprotein cholesterol (HDL-C). The EPA group also exhibited significant decreases in the incremental TG peak, area under the curve (AUC) for postprandial TG, incremental glucose peak, AUC for postprandial glucose, and improvements in glycometabolism categorization. No significant changes were observed for hemoglobin A1c and fasting plasma glucose levels. The EPA group exhibited a significant increase in AUC-immune reactive insulin/AUC-plasma glucose ratio (which indicates postprandial insulin secretory ability) and significant improvements in FMD. Multiple regression analysis revealed that decreases in the TG/HDL-C ratio and incremental TG peak were independent predictors of FMD improvement in the EPA group. CONCLUSIONS: EPA corrected postprandial hypertriglyceridemia, hyperglycemia and insulin secretion ability. This amelioration of several metabolic abnormalities was accompanied by recovery of concomitant endothelial dysfunction in newly diagnosed IGM patients with CAD. Clinical Trial Registration UMIN Registry number: UMIN000011265 ( https://www.upload.umin.ac.jp/cgi-open-bin/ctr/ctr.cgi?function=brows&action=brows&type=summary&recptno=R000013200&language=E ).


Asunto(s)
Enfermedad de la Arteria Coronaria/tratamiento farmacológico , Ácido Eicosapentaenoico/administración & dosificación , Endotelio Vascular/efectos de los fármacos , Hiperglucemia/tratamiento farmacológico , Hipertrigliceridemia/tratamiento farmacológico , Hipoglucemiantes/administración & dosificación , Hipolipemiantes/administración & dosificación , Insulina/metabolismo , Periodo Posprandial , Anciano , Biomarcadores/sangre , Glucemia/efectos de los fármacos , Glucemia/metabolismo , Enfermedad de la Arteria Coronaria/sangre , Enfermedad de la Arteria Coronaria/diagnóstico , Enfermedad de la Arteria Coronaria/fisiopatología , Esquema de Medicación , Ácido Eicosapentaenoico/efectos adversos , Endotelio Vascular/fisiopatología , Femenino , Humanos , Hiperglucemia/sangre , Hiperglucemia/diagnóstico , Hiperglucemia/fisiopatología , Hipertrigliceridemia/sangre , Hipertrigliceridemia/diagnóstico , Hipertrigliceridemia/fisiopatología , Hipoglucemiantes/efectos adversos , Hipolipemiantes/efectos adversos , Mediadores de Inflamación/sangre , Insulina/sangre , Secreción de Insulina , Japón , Masculino , Persona de Mediana Edad , Estudios Prospectivos , Recuperación de la Función , Método Simple Ciego , Factores de Tiempo , Resultado del Tratamiento , Triglicéridos/sangre , Vasodilatación/efectos de los fármacos
4.
J Cardiovasc Electrophysiol ; 26(11): 1239-1246, 2015 Nov.
Artículo en Inglés | MEDLINE | ID: mdl-26223827

RESUMEN

BACKGROUND: Current guidelines recommend the implantation of an implantable cardioverter-defibrillator (ICD) for primary prevention of sudden cardiac death (SCD) in a subgroup of patients with nonischemic cardiomyopathy (NICM) who have a left ventricular ejection fraction (LVEF) ≤ 30-35%, and are NYHA functional class II or III. However, the majority of patients with an ICD implantation for primary prevention did not receive appropriate ICD therapy. The purpose of this study was to evaluate the association between myocardial fibrosis detected by cardiovascular magnetic resonance (CMR) imaging and life-threatening ventricular arrhythmic events in NICM patients. METHODS: One hundred and seventy-five NICM patients with an LVEF ≦ 35 % and NYHA functional class II or III, (60 ± 15 years, LVEF 29 ± 5.4%) were studied. Myocardial fibrosis was identified with a late gadolinium enhancement (LGE) on CMR. Clinical events were defined as SCD or life-threatening ventricular arrhythmic events and were followed up for 5.1 ± 3.3 years. RESULTS: The presence of an LGE was detected in 122 patients (70%). No life-threatening ventricular arrhythmia events occurred in patients with the absence of an LGE. A total of 18 ventricular tachycardia and 8 ventricular fibrillation events were found in patients with the presence of an LGE (P < 0.01). Sensitivity, specificity, and positive and negative predictive value of LGE in predicting life-threatening ventricular arrhythmia events were 100%, 34%, and 15% and 100%, respectively. Multivariate analysis showed that the presence of both septal and lateral mid-wall LGE was associated with life-threatening ventricular arrhythmic events (hazard ratio 23.1 CI; 2.88-184.9, P = 0.003). CONCLUSIONS: The absence of an LGE predicts a low potential risk of SCD and life-threatening ventricular arrhythmia events in the near future. CMR may be a useful tool for selecting suitable patients for primary ICD implantations in NICM patients.

5.
Circ J ; 79(8): 1727-32, 2015.
Artículo en Inglés | MEDLINE | ID: mdl-25993904

RESUMEN

BACKGROUND: The incidence of hematoma formation following implantation of a cardiovascular implantable electronic device (CIED) is estimated to be 5% even if a pressure dressing is applied. It is unclear whether a pressure dressing can really compress the pocket in different positions. Furthermore, the adhesive tape for fixing pressure dressings can tear the skin. We developed a new compression tool for preventing hematomas and skin erosions. METHODS AND RESULTS: We divided 46 consecutive patients receiving anticoagulation therapy who underwent CIED implantation into 2 groups (Group I: conventional pressure dressing, Group II: new compression tool). The pressure on the pocket was measured in both the supine and standing positions. The incidence of hematomas was compared between the 2 groups. The pressure differed between the supine and standing positions in Group I, but not in Group II (Group I: 14.8±7.1 mmHg vs. 11.3±9.9 mmHg, P=0.013; Group II: 13.5±2.8 mmHg vs. 13.5±3.5 mmHg, P=0.99). The incidence of hematomas and skin erosions was documented in 2 (8.7%) and 3 (13%) Group I patients, respectively. No complications were documented in Group II. CONCLUSIONS: The new compression tool can provide adequate continuous pressure on the pocket, regardless of body position. This device may reduce the incidence of hematomas and skin erosions after CIED implantation.


Asunto(s)
Vendajes de Compresión , Desfibriladores Implantables , Hematoma/prevención & control , Enfermedades de la Piel/prevención & control , Anciano , Anciano de 80 o más Años , Femenino , Humanos , Masculino
6.
Echocardiography ; 31(4): 464-73, 2014 Apr.
Artículo en Inglés | MEDLINE | ID: mdl-24138588

RESUMEN

The objective of this study was to test the hypothesis that combining assessment of baseline radial strain dyssynchrony index (SDI), that expressed both left ventricular (LV) dyssynchrony and residual myocardial contractility, and of acute changes in this index can yield more accurate prediction of mid-term responders and long-term outcome after cardiac resynchronization therapy (CRT). Radial SDI for 75 CRT patients was calculated as the average difference between peak and end-systolic speckle tracking strain from 6 segments of the mid-LV short-axis view before and 8 ± 2 days after CRT. Mid-term responder was defined as ≥ 15% decrease in LV end-systolic volume 6 ± 2 months after CRT. Long-term outcome was tracked over 5 years. Baseline radial SDI ≥ 6.5% is considered predictive of responder and favorable outcome, as previously reported. Acute reduction in radial SDI ≥ 1.5% was found to be the best predictor of mid-term responders with CRT. Furthermore, patients with acute reductions in radial SDI ≥1.5% were associated with a significantly more favorable long-term outcome after CRT than those with radial SDI <1.5% (log rank P < 0.001). An important findings were that baseline radial SDI ≥6.5% and acute reductions in radial SDI ≥ 1.5% in 42 patients were associated with the highest event-free survival rate of 92%, whereas, 21 patients corresponding values of <6.5% and <1.5% were associated with low event-free survival rate of 46% (log rank P < 0.001). Combined assessment of baseline radial SDI and its acute reduction after CRT may have clinical implications for predicting responders and thus patients' care.


Asunto(s)
Terapia de Resincronización Cardíaca/métodos , Ecocardiografía Doppler en Color/métodos , Insuficiencia Cardíaca/terapia , Volumen Sistólico/fisiología , Remodelación Ventricular/fisiología , Anciano , Anciano de 80 o más Años , Estudios de Cohortes , Femenino , Estudios de Seguimiento , Insuficiencia Cardíaca/diagnóstico por imagen , Insuficiencia Cardíaca/mortalidad , Humanos , Estimación de Kaplan-Meier , Masculino , Persona de Mediana Edad , Variaciones Dependientes del Observador , Valor Predictivo de las Pruebas , Modelos de Riesgos Proporcionales , Curva ROC , Estudios Retrospectivos , Tasa de Supervivencia , Factores de Tiempo , Resultado del Tratamiento , Disfunción Ventricular Izquierda/diagnóstico por imagen , Disfunción Ventricular Izquierda/mortalidad , Disfunción Ventricular Izquierda/terapia
7.
J Cardiol Cases ; 30(3): 90-93, 2024 Sep.
Artículo en Inglés | MEDLINE | ID: mdl-39483407

RESUMEN

Polymyositis (PM) and dermatomyositis (DM) are chronic inflammatory muscle disorders characterized by muscle weakness and fatigue. They are histopathologically defined by inflammatory cell infiltrates in the skeletal muscle. In a recent meta-analysis, the incidence of cardiovascular complications in patients with PM/DM ranged from 9 to 72 %, with heart failure being the most commonly reported heart disease. In cases of heart failure accompanied by severe mitral regurgitation that is refractory due to guideline-directed medical therapy, the transcatheter edge-to-edge mitral valve repair (TEER) procedure using the MitraClip (Abbott Vascular, Santa Clara, CA, USA) offers an alternative therapeutic approach. We present a pioneering case report describing the successful application of TEER in a young woman with drug-refractory heart failure due to cardiovascular involvement in PM. Learning objective: •In polymyositis (PM)/ dermatomyositis (DM), the most commonly reported clinical heart disorder is heart failure, with some cases attributed to mitral regurgitation.•Patients suffering from systemic inflammatory diseases such as PM/DM often face high surgical risk, and the MitraClip is an effective treatment modality.

8.
Int J Cardiol ; 418: 132664, 2024 Oct 18.
Artículo en Inglés | MEDLINE | ID: mdl-39426417

RESUMEN

BACKGROUND: The prevalence of wild-type transthyretin (ATTR) amyloidosis is increasing with advancements in diagnostic techniques and growing awareness of the disease worldwide. 99mTc-labeled pyrophosphate (99mTc-PYP) scintigraphy exhibits high performance in diagnosing ATTR cardiac amyloidosis. This study aimed to validate the characteristics of patients with positive 99mTc-PYP scintigraphy results in a multicenter setting to provide more accurate case selection criteria. METHODS AND RESULTS: In total, 180 patients with suspected ATTR amyloidosis underwent 99mTc-PYP scintigraphy in participating institutions in Japan between January 2018 and July 2022. Of 135 patients included in the analysis, 62 were 99mTc-PYP-positive. Logistic regression analysis was performed, and the following five factors were adopted to create a scoring system, with each weighted according to its odds ratio value; 1 point was scored for the absence of hypertension, existence of peripheral entrapment neuropathy (carpal tunnel syndrome or spinal canal stenosis), conduction disturbance (the presence of QRS complex ≥120 ms, first-degree atrioventricular block, higher degree of atrioventricular block, or presence of pacemaker implantation), and left ventricular hypertrophy and 2 points for troponin I/T ≥ 0.06 ng/mL. 99mTc-PYP scintigraphy positivity rate in the 0-point group was 0 %, whereas that in the 6-point group was 100 %. The area under the curve of the criteria was 0.820 (95 % confidence interval, 0.752-0.888; P < 0.001). CONCLUSIONS: The combination of clinical information, which is easily available in local clinics, can provide accurate pretest prediction of positive 99mTc-PYP scintigraphy results. This will help clinicians to make an early diagnosis of ATTR amyloidosis.

9.
J Cardiol ; 83(3): 169-176, 2024 Mar.
Artículo en Inglés | MEDLINE | ID: mdl-37543193

RESUMEN

BACKGROUND: Transcatheter aortic valve replacement (TAVR) for severe symptomatic aortic stenosis (AS) does not benefit all patients. We performed a prospective multicenter study to investigate the cost-effectiveness of TAVR in a Japanese cohort. METHODS AND RESULTS: We prospectively enrolled 110 symptomatic patients with severe AS who underwent TAVR from five institutions. The quality of life measurement (QOL) was performed for each patient before and at 6 months after TAVR. Patients without an improvement in QOL at 6 months after TAVR were defined as non-responders. Pre-TAVR higher QOL, higher clinical frailty scale predicted the non-responders. Three models, 1) conservative treatment for all patients strategy, 2) TAVR for all patients strategy, and 3) TAVR for a selected patient strategy who is expected to be a responder, were simulated. Lifetime cost-effectiveness was estimated using incremental cost-effectiveness ratio (ICER) and cost per quality-adjusted life-year (QALY) gained. In comparison to conservative therapy for all patients, ICER was estimated to be 5,765,800 yen/QALY for TAVR for all patients and 2,342,175 yen/QALY for TAVR for selected patient strategy patients, which is less than the commonly accepted ICER threshold of 5,000,000 yen/QALY. CONCLUSIONS: TAVR for selected patient strategy model is more cost-effective than TAVR for all patient strategy without reducing QOL in the Japanese healthcare system. TAVR for selected patient strategy has potential benefit for optimizing the TAVR treatment in patients with high frailty and may direct our resources toward beneficial interventions.


Asunto(s)
Estenosis de la Válvula Aórtica , Fragilidad , Implantación de Prótesis de Válvulas Cardíacas , Reemplazo de la Válvula Aórtica Transcatéter , Humanos , Reemplazo de la Válvula Aórtica Transcatéter/métodos , Implantación de Prótesis de Válvulas Cardíacas/métodos , Calidad de Vida , Análisis Costo-Beneficio , Estudios Prospectivos , Fragilidad/etiología , Estenosis de la Válvula Aórtica/etiología , Índice de Severidad de la Enfermedad , Resultado del Tratamiento , Válvula Aórtica/cirugía , Factores de Riesgo
10.
J Echocardiogr ; 22(3): 113-151, 2024 Sep.
Artículo en Inglés | MEDLINE | ID: mdl-38722468

RESUMEN

In recent years, bedside ultrasound examinations have been used in many clinical departments and are called point-of-care ultrasound (POCUS). Regarding POCUS in the cardiac field, a protocol called focus (focused) cardiac ultrasound (FoCUS) has been developed in Europe and the United States, is being used clinically, and an educational syllabus has been created. According to them, FoCUS is defined as a point-of-care cardiac ultrasound examination using standardized limited sections and protocols. FoCUS is primarily intended to be performed by non-cardiologists, and in order to avoid making mistakes in judgment, it is important to be familiar with its limitations and it is necessary to understand pathological conditions that can only be diagnosed using conventional comprehensive echocardiography. The Japanese Society of Echocardiography has edited this clinical guideline because we believe that FoCUS should be used effectively and appropriately in Japan, and that appropriate education is essential to popularize FoCUS in Japan. Furthermore, lung POCUS has recently come into clinical use. Lung POCUS is useful for the diagnosis and follow-up of heart failure when used in conjunction with FoCUS, and is especially useful in primary care where chest X-rays are not available. The working group that created this manual agreed that it is desirable to educate patients about lung POCUS in conjunction with FoCUS, so we decided to include the basic techniques of lung POCUS and how to use them in this manuscript.


Asunto(s)
Ecocardiografía , Sistemas de Atención de Punto , Sociedades Médicas , Humanos , Ecocardiografía/métodos , Japón , Pulmón/diagnóstico por imagen
11.
J Cardiovasc Magn Reson ; 15: 95, 2013 Oct 17.
Artículo en Inglés | MEDLINE | ID: mdl-24134158

RESUMEN

BACKGROUND: Analysis of left ventricular (LV) mechanical dyssynchrony may provide incremental prognostic information regarding cardiac resynchronization therapy (CRT) response in addition to QRS width alone. Our objective was to quantify LV dyssynchrony using feature tracking post processing of routine cardiovascular magnetic resonance (CMR) cine acquisitions (FT-CMR) in comparison to speckle tracking echocardiography. METHODS: We studied 72 consecutive patients who had both steady-state free precession CMR and echocardiography. Mid-LV short axis CMR cines were analyzed using FT-CMR software and compared with echocardiographic speckle tracking radial dyssynchrony (time difference between the anteroseptal and posterior wall peak strain). RESULTS: Radial dyssynchrony analysis was possible by FT-CMR in all patients, and in 67 (93%) by echocardiography. Dyssynchrony by FT-CMR and speckle tracking showed limits of agreement of strain delays of ± 84 ms. These were large (up to 100% or more) relative to the small mean delays measured in more synchronous patients, but acceptable (mainly <25%) in those with mean delays of >200 ms. Radial dyssynchrony was significantly greater in wide QRS patients than narrow QRS patients by both FT-CMR (radial strain delay 230 ± 94 vs. 77 ± 92* ms) and speckle tracking (radial strain delay 242 ± 101 vs. 75 ± 88* ms, all *p < 0.001). CONCLUSIONS: FT-CMR delivered measurements of radial dyssynchrony from CMR cine acquisitions which, at least for the patients with more marked dyssynchrony, showed reasonable agreement with those from speckle tracking echocardiography. The clinical usefulness of the method, for example in predicting prognosis in CRT patients, remains to be investigated.


Asunto(s)
Ecocardiografía , Imagen por Resonancia Cinemagnética , Disfunción Ventricular Izquierda/diagnóstico , Función Ventricular Izquierda , Adulto , Anciano , Algoritmos , Automatización de Laboratorios , Fenómenos Biomecánicos , Estudios de Factibilidad , Femenino , Humanos , Interpretación de Imagen Asistida por Computador , Masculino , Persona de Mediana Edad , Valor Predictivo de las Pruebas , Programas Informáticos , Estrés Mecánico , Factores de Tiempo , Disfunción Ventricular Izquierda/diagnóstico por imagen , Disfunción Ventricular Izquierda/fisiopatología
12.
Echocardiography ; 30(2): 147-54, 2013 Feb.
Artículo en Inglés | MEDLINE | ID: mdl-23167507

RESUMEN

BACKGROUND: Effectiveness of functional mitral regurgitation (FMR) in heart failure patients is of growing importance for patient prognosis. The purpose of this study was to investigate whether regional myocardial contractile function as assessed by tissue Doppler strain rate imaging can predict reduction in FMR caused by dobutamine. METHODS: Fifty-one patients with depressed left ventricular (LV) ejection fraction (32 ± 9%) secondary to dilated cardiomyopathy and FMR underwent evaluation of effective regurgitant orifice (ERO) of FMR, mitral valve deformation, global LV remodeling, and regional myocardial contractile function assessed by longitudinal peak systolic strain rate (Ssr) in 6 mid-LV segments from standard apical views. We also determined the average Ssr of segments attached to the papillary muscles, that is, the inferior, inferolateral, and anterolateral segments (PM segments Ssr). Low-dose (10 µg/kg per minute) dobutamine-induced reduction in ERO was compared with baseline variables. RESULTS: Baseline valve tenting was associated with dobutamine-induced reduction in ERO (r = -0.30, P < 0.05). Receiver operating characteristic curve analysis showed that baseline valve tenting, LV sphericity index, inferior Ssr, inferolateral Ssr, and PM segments Ssr were predictors of dobutamine-induced ≥30% reduction in ERO. Importantly, only PM segments Ssr predicted dobutamine-induced ≥20% reduction in valve tenting with area under the curve of 0.67 (P < 0.05). CONCLUSIONS: Preserved myocardial contractile function in the segments attached to the PMs was associated with dobutamine-induced reduction in mitral valve tenting and FMR, suggesting that our findings are important for improvement in cardiac function and FMR with medical treatment.


Asunto(s)
Ecocardiografía Doppler en Color/métodos , Ecocardiografía de Estrés/métodos , Insuficiencia de la Válvula Mitral/fisiopatología , Contracción Miocárdica/fisiología , Músculos Papilares/diagnóstico por imagen , Función Ventricular Izquierda/fisiología , Anciano , Femenino , Estudios de Seguimiento , Humanos , Masculino , Insuficiencia de la Válvula Mitral/diagnóstico por imagen , Músculos Papilares/fisiopatología , Índice de Severidad de la Enfermedad
13.
Eur Heart J Case Rep ; 7(3): ytad101, 2023 Mar.
Artículo en Inglés | MEDLINE | ID: mdl-36923114

RESUMEN

Background: Atrial functional mitral regurgitation (AFMR) is an entity of mitral regurgitation (MR) in atrial fibrillation (AF) with dilated left atrium (LA) and/or normal left ventricular function. Transcatheter edge-to-edge mitral valve repair with MitraClip is reportedly an effective therapy for AFMR. However, performing MitraClip for patients with such condition is challenging because of its characteristic morphology. Case summary: An 80-year-old man with permanent AF and severe MR was hospitalized for heart failure with preserved ejection fraction. On echocardiography, a marked dilation of the LA caused the anterior mitral leaflet to flatten along the mitral annulus (MA) plane. The posterior mitral leaflet was tethered towards the posterior left ventricle, thus producing a coaptation gap of 6.5 mm between the leaflets. Given his high surgical risk, MitraClip therapy was performed, but leaflet grasping was difficult because of the notable coaptation gap. When positive end-expiratory pressure (PEEP) was applied by mechanical ventilation, the MA gradually decreased in diameter. Under 20 cm H2O of PEEP, the coaptation gap decreased to 0 mm, which finally enabled the grasping of the leaflets. The clip was deployed, thus leaving only mild MR. Thereafter, the patient had an uneventful clinical course. Discussion: In patients with AFMR, the sagittal dilation of the MA and asymmetry in the tethering angles of the leaflets often produce a marked coaptation gap, which poses a challenge in MitraClip therapy. In our patient, the ventilator-assisted technique effectively reduced the coaptation gap between the leaflets, thus leading to successful results.

14.
J Cardiol Cases ; 27(6): 279-282, 2023 Jun.
Artículo en Inglés | MEDLINE | ID: mdl-37283912

RESUMEN

Infective endocarditis (IE) is a rare, life-threatening complication of MitraClip (Abbott, Abbott Park, IL, USA) therapy. We report a case of an 84-year-old male who underwent transcatheter edge-to-edge mitral valve (MV) repair using MitraClip (Abbott, Abbott Park, IL, USA) 4 weeks prior for ventricular functional mitral regurgitation (MR) and returned with unstable hemodynamics and high-grade fever. Transthoracic echocardiography (TTE) on emergency admission showed thickening of the anterior mitral leaflet (AML) without apparent MR deterioration. TTE and transesophageal echocardiography (TEE) performed the next day showed severe MR due to rapidly progressing AML degeneration with aneurysmal formation. During the TEE examination, exacerbated heart failure due to severe MR caused cardiogenic shock and subsequent ventricular fibrillation, necessitating emergency extracorporeal cardiopulmonary resuscitation. Considering the positive findings of methicillin-resistant Staphylococcus aureus (MRSA) in blood cultures and degenerative MV findings, MitraClip-related IE was diagnosed; finally, MV replacement was performed. Retrospective consideration suggested that the potential causes of this MitraClip-related IE were valve injuries caused by multiple full-close procedures and insufficient prophylaxis for preoperatively detected MRSA. MitraClip-related IE has destructive characteristics that necessitate surgical intervention despite high risks; therefore, we should prevent procedure-related MV injuries and implement preoperative infection precautions to prevent catastrophic complications, particularly in patients with preoperative nasal MRSA-positive findings. Learning objectives: MitraClip-related infective endocarditis (IE) is a rare but fatal condition. IE caused by methicillin-resistant Staphylococcus aureus (MRSA), in particular, has an inferior prognosis with high mortality rates due to its destructive nature. Therefore, interventionalists should consider preventive strategies to avoid procedure-related valve injuries and adequately prepare for prophylaxis of patients who are carriers of MRSA to prevent MitraClip-related IE caused by MRSA.

15.
Circ J ; 76(3): 744-51, 2012.
Artículo en Inglés | MEDLINE | ID: mdl-22214899

RESUMEN

BACKGROUND: The purpose of this study was to investigate whether patients with severe aortic stenosis (AS) and preserved ejection fraction (EF) have dyssynchrony and whether it improves after aortic valve replacement (AVR). METHODS AND RESULTS: We studied 30 consecutive patients with severe AS and preserved EF undergoing AVR. For baseline comparison, we studied 17 EF-matched patients with mild-to-moderate AS, and 18 EF-matched normal volunteers. Longitudinal dyssynchrony was determined as the standard deviation for time-to-peak speckle-tracking strain in apical 4- and 2-chamber views at the basal- and mid-levels. Radial and circumferential dyssynchrony was determined as the difference for time-to-peak strain between the anteroseptum and posterior wall from the mid-left ventricular (LV) short-axis view. Each of the myocardial functions was also evaluated by averaging each peak systolic strain. Longitudinal dyssynchrony and function in patients with severe AS was significantly worse than in the patients with mild-to-moderate AS and the controls (94 ± 46 vs. 66 ± 18 ms* and 52 ± 17 ms*, and 12.5 ± 3.7% vs. 16 ± 3.5%* and 18.7 ± 3.7%*, respectively, *P<0.05, vs. severe AS). In contrast, radial and circumferential dyssynchrony were similar for the 3 groups. Importantly, the dyssynchrony of patients with severe AS significantly improved after AVR from 94 ± 46 ms to 68 ± 22 ms (P<0.005). CONCLUSIONS: Significant longitudinal dyssynchrony was present in patients with severe AS and preserved EF, and it improved after AVR.


Asunto(s)
Estenosis de la Válvula Aórtica/fisiopatología , Válvula Aórtica/cirugía , Volumen Sistólico , Disfunción Ventricular Izquierda/fisiopatología , Anciano , Anciano de 80 o más Años , Estenosis de la Válvula Aórtica/cirugía , Estudios de Casos y Controles , Femenino , Implantación de Prótesis de Válvulas Cardíacas , Humanos , Masculino , Persona de Mediana Edad , Sístole , Resultado del Tratamiento
16.
Echocardiography ; 29(4): 411-8, 2012 Apr.
Artículo en Inglés | MEDLINE | ID: mdl-22329730

RESUMEN

BACKGROUND: Isometric handgrip stress test is a simple method for detecting coronary artery disease (CAD). However, the value of this method alone is limited by relatively low sensitivity. This study thus aimed to investigate the usefulness of two-dimensional speckle-tracking strain combined with handgrip for CAD patients. METHOD: We studied 35 patients with stable angina pectoris who underwent percutaneous coronary intervention (PCI). Longitudinal (L-ɛ) and transverse peak systolic (T-ɛ) strains were measured from three standard apical views before and 1 month after PCI. Segments corresponded to perfusion territories of coronary arteries were divided into two groups based on coronary angiography results: stenotic (S) and nonstenotic (NS) segment. RESULTS: L-ɛ in S segments increased significantly after PCI, from -15.8% to -17.6% (P < 0.01), but not in NS segments. Moreover, L-ɛ in S segments increased significantly during handgrip before PCI, from -15.8% to -17.6% (P < 0.01), but decreased after PCI, from -17.6% to -16.7% (P = 0.02). In contrast, L-ɛ in NS segments decreased significantly during the isometric handgrip stress test before and after PCI (P < 0.05). Especially noteworthy is that a relative change in L-ɛ of >1.2% during handgrip before PCI could detect significant coronary stenosis with a sensitivity of 80%, specificity of 66%, and area under the curve of 0.77 (P < 0.001). On the other hand, no significant changes were observed in either T-ɛ segments during handgrip either before or after PCI. CONCLUSION: Longitudinal speckle-tracking strain combined with handgrip may constitute a valuable tool for detection of ischemic myocardial segments and prediction of improvement of regional contraction after revascularization.


Asunto(s)
Angina Estable/diagnóstico por imagen , Ecocardiografía/métodos , Diagnóstico por Imagen de Elasticidad/métodos , Prueba de Esfuerzo/métodos , Fuerza de la Mano , Anciano , Femenino , Humanos , Estudios Longitudinales , Reproducibilidad de los Resultados , Sensibilidad y Especificidad
17.
Pediatr Int ; 54(3): 388-92, 2012 Jun.
Artículo en Inglés | MEDLINE | ID: mdl-22248373

RESUMEN

BACKGROUND: The aim of this study was to predict left ventricular (LV) dysfunction and the timing to perform echocardiography in patients with Duchenne muscular dystrophy (DMD). We developed a scoring system using clinical parameters and examined its efficacy. It is indispensable to utilize echocardiogram for evaluating myocardial damage of DMD patients, but there is no established guideline for determining the clinical conditions which require echocardiographic examination. METHODS: We retrospectively analyzed 86 patients with DMD who were treated in Kobe University Hospital from 2007 to 2009. The multiple logistic regression analysis on routine clinical data was performed to identify parameters that can find abnormal LV contraction, and to develop a weighted scoring system. Echocardiogram was performed as the gold standard for detecting LV dysfunction. RESULTS: Four parameters were associated with abnormal LV contraction: (i) brain natriuretic peptide (BNP); (ii) creatine kinase; (iii) scoliosis; and (iv) body surface area. When BNP was used as the only predictor to evaluate LV systolic dysfunction, sensitivity and specificity were 36.4% and 92.1%, respectively. In contrast, abnormal LV contraction was detected in high accuracy (sensitivity: 95.5%; specificity: 68.3%) when we used a two-step scoring system in which BNP was combined with the other three factors, raising the sensitivity compared to using BNP levels as the single parameter (P= 0.008). CONCLUSION: Our scoring system detects the early heart dysfunction of DMD patients, especially when BNP level is not elevated. This system is useful to determine the timing for echocardiographic examination and consulting cardiologists.


Asunto(s)
Distrofia Muscular de Duchenne/complicaciones , Disfunción Ventricular Izquierda/diagnóstico , Disfunción Ventricular Izquierda/etiología , Adolescente , Adulto , Niño , Preescolar , Humanos , Pronóstico , Estudios Retrospectivos , Adulto Joven
18.
J Echocardiogr ; 20(4): 195-200, 2022 12.
Artículo en Inglés | MEDLINE | ID: mdl-36053459

RESUMEN

Echocardiography plays a pivotal role as an imaging modality in modern cardiology practice. Information derived from echocardiography is essential for patient care. The Japanese Society of Echocardiography has promoted echocardiography for routine clinical and research use. One of the missions of the Society is to provide information that is useful for high-quality examinations. To ensure this, we believe that maintaining equipment in good condition and providing a comfortable environment for the examination are important for both the patient and examiner. Thus, the Committee for Guideline Writing of the Japanese Society of Echocardiography originally published brief guidance for the routine use of echocardiography equipment in 2015. In 2018, the committee updated our guidance incorporating the importance of international standardization. In 2022, the committee has revised and updated our guidance in line with the increase in awareness of infection prevention due to the worldwide spread of coronavirus disease 2019 (COVID-19).


Asunto(s)
COVID-19 , Cardiología , Humanos , Japón , Ecocardiografía
19.
J Cardiol ; 80(3): 218-225, 2022 09.
Artículo en Inglés | MEDLINE | ID: mdl-35307223

RESUMEN

BACKGROUND: The predictive value of echocardiographic parameters for early worsening heart failure (WHF), worsening of symptoms of heart failure requiring intensification of therapy during an admission for acute decompensated heart failure (ADHF), has not been elucidated. METHODS: Sixteen centers in Japan prospectively enrolled 303 ADHF hospitalized patients who did not receive positive inotropic agents as an initial therapy. Physical and Doppler echocardiographic examinations were performed before the initial therapy and the association of low output findings and occurrence of early WHF were tested. RESULTS: Early WHF occurred in 63 patients with a median duration of 6 (IQR: 2-23) hours from the administration of the initial therapy. In patients with left ventricular (LV) ejection fraction <40% (N = 153), echocardiographic stroke volume index, and cardiac index showed greater c-index [95% confidence interval, 0.71 (0.61-0.79) and 0.72 (0.63-0.80), respectively] compared to single low perfusion finding (symptomatic hypotension, reduced pulse pressure, and impaired mentation) other than cool extremities. When physical findings were combined (low perfusion score), the predictive ability improved to the similar levels of echocardiographic LV output parameters [c-index: 0.69 (0.60-0.76)]. However, addition of cardiac index significantly improved the prognostic ability when added to low perfusion score [0.82 (0.74-0.87), p < 0.001]. In contrast, in patients with LV ejection fraction ≥40% (N = 150), low perfusion score, rather than LV output parameters, was predictive of early WHF [c-index: 0.73 (0.56-0.85)]. CONCLUSIONS: We demonstrated the predictive value of echocardiographic LV output indices for early WHF in ADHF patients with LV systolic dysfunction. These data support the motivation for routine use of echocardiography for initial assessment of ADHF.


Asunto(s)
Insuficiencia Cardíaca , Ecocardiografía/métodos , Ecocardiografía Doppler , Humanos , Volumen Sistólico , Función Ventricular Izquierda
20.
Eur J Echocardiogr ; 12(4): 283-90, 2011 Apr.
Artículo en Inglés | MEDLINE | ID: mdl-21266379

RESUMEN

AIMS: The aim of this study was to test the hypothesis that, unlike calculation of the mitral valve area (MVA) with the pressure half-time method (PHT), the proximal isovelocity surface area method (PISA) is not affected by changes in net atrioventricular compliance (C(n)). METHODS AND RESULTS: We studied 51 patients with mitral stenosis (MS) from two centres. MVA was assessed with the PISA (MVA(PISA)), PHT (MVA(PHT)), and planimetry (MVA(PLN), serving as the gold standard) method. C(n) was calculated with a previously validated equation using 2D echocardiography. MVA(PISA) closely correlated with MVA(PLN) (r = 0.96, P < 0.0001), while MVA(PHT) and MVA(PLN) showed a weaker but still good correlation (r = 0.69, P < 0.0001). The correlation between MVA(PHT) and MVA(PLN) for patients with C(n) between 4 and 6 mL/mmHg (considered to be normal) was excellent (r = 0.93, P < 0.0001), but that for patients with C(n) of less than 4 or more than 6 mL/mmHg was not as good (r = 0.64, P < 0.0001). Importantly, a significant inverse correlation was detected between the percentage difference among MVA(PHT), MVA(PLN), and C(n) (r = -0.77, P < 0.0001), but the line of fit was nearly flat for the percentage difference among MVA(PISA), MVA(PLN), and C(n) (r = 0.1, P = 0.388). CONCLUSION: MVA calculated with both the PISA and PHT methods correlated well with MVA calculated with the planimetry method. However, the PISA rather than PHT is recommended for patients with MS and extreme C(n) values because PISA, unlike PHT, is not affected by changes in C(n).


Asunto(s)
Ecocardiografía/métodos , Estenosis de la Válvula Mitral/diagnóstico por imagen , Válvula Mitral/diagnóstico por imagen , Velocidad del Flujo Sanguíneo , Ecocardiografía Doppler en Color/métodos , Femenino , Humanos , Modelos Lineales , Masculino , Persona de Mediana Edad , Válvula Mitral/fisiopatología , Estenosis de la Válvula Mitral/fisiopatología , Estudios Prospectivos , Índice de Severidad de la Enfermedad
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA