1.
Magn Reson Med ; 83(3): 1025-1033, 2020 03.
Artículo en Inglés | MEDLINE | ID: mdl-31502711

RESUMEN

PURPOSE: The clinical application of sodium MRI is hampered due to relatively low image quality and associated long acquisition times. Compressed sensing (CS) aims at a reduction of measurement time, but has been found to encompass quantitative estimation bias when used in low SNR x-Nuclei imaging. This work analyses CS in quantitative human brain sodium MRI from undersampled acquisitions and provides recommendations for tissue sodium concentration (TSC) estimation. METHODS: CS reconstructions from 3D radial acquisitions of 5 healthy volunteers were investigated over varying undersampling factors (USFs) and CS penalty weights on different sparsity domains, Wavelet, Discrete Cosine Transform (DCT), and Identity. Resulting images were compared with highly sampled and undersampled NUFFT-based images and evaluated for image quality (i.e. structural similarity), image intensity bias, and its effect on TSC estimates in gray and white matter. RESULTS: Wavelet-based CS reconstructions show highest image quality with stable TSC estimates for most USFs. Up to an USF of 4, images showed good structural detail. DCT and Identity-based CS enable good image quality, however show a bias in TSC with a reduction in estimates across USFs. CONCLUSIONS: The image intensity bias is lowest in Wavelet-based reconstructions and enables an up to fourfold acquisition speed up while maintaining good structural detail. The associated acquisition time reduction can facilitate a translation of sodium MRI into clinical routine.


Asunto(s)
Encéfalo/diagnóstico por imagen , Procesamiento de Imagen Asistido por Computador/métodos , Imagen por Resonancia Magnética , Sodio/química , Adulto , Algoritmos , Artefactos , Compresión de Datos , Femenino , Voluntarios Sanos , Humanos , Interpretación de Imagen Asistida por Computador/métodos , Masculino , Fantasmas de Imagen , Reproducibilidad de los Resultados , Relación Señal-Ruido , Análisis de Ondículas
2.
Magn Reson Med ; 83(4): 1178-1191, 2020 04.
Artículo en Inglés | MEDLINE | ID: mdl-31502729

RESUMEN

PURPOSE: To demonstrate simultaneous T1 -weighted imaging, T1 mapping, R2∗ mapping, SWI, and QSM from a single multi-echo (ME) MP2RAGE acquisition. METHODS: A single-echo (SE) MP2RAGE sequence at 7 tesla was extended to ME with 4 bipolar gradient echo readouts. T1 -weighted images and T1 maps calculated from individual echoes were combined using sum of squares and averaged, respectively. ME-combined SWI and associated minimum intensity projection images were generated with TE-adjusted homodyne filters. A QSM reconstruction pipeline was used, including a phase-offsets correction and coil combination method to properly combine the phase images from the 32 receiver channels. Measurements of susceptibility, R2∗ , and T1 of brain tissue from ME-MP2RAGE were compared with those from standard ME-gradient echo and SE-MP2RAGE. RESULTS: The ME combined T1 -weighted, T1 map, SWI, and minimum intensity projection images showed increased SNRs compared to the SE results. The proposed coil combination method led to QSM results free of phase-singularity artifacts, which were present in the standard adaptive combination method. T1 -weighted, T1 , and susceptibility maps from ME-MP2RAGE were comparable to those obtained from SE-MP2RAGE and ME-gradient echo, whereas R2∗ maps showed increased blurring and reduced SNR. T1 , R2∗ , and susceptibility values of brain tissue from ME-MP2RAGE were consistent with those from SE-MP2RAGE and ME-gradient echo. CONCLUSION: High-resolution structural T1 weighted imaging, T1 mapping, R2∗ mapping, SWI, and QSM can be extracted from a single 8.5-min ME-MP2RAGE acquisition using a customized reconstruction pipeline. This method can be applied to replace separate SE-MP2RAGE and ME-gradient echo acquisitions to significantly shorten total scan time.


Asunto(s)
Procesamiento de Imagen Asistido por Computador , Imagen por Resonancia Magnética , Encéfalo/diagnóstico por imagen , Mapeo Encefálico , Relación Señal-Ruido
3.
Magn Reson Med ; 81(2): 1172-1180, 2019 02.
Artículo en Inglés | MEDLINE | ID: mdl-30252156

RESUMEN

PURPOSE: Fast bi-exponential transverse signal decay compounds sodium image quality. This work aims at enhancing image characteristics using a special case of ramped hybrid encoding (RHE). Zero-gradient-excitation (zGRF )-RHE provides (1) gradient-free excitation for high flip angle, artifact-free excitation profiles and (2) gradient ramping during dead-time for the optimization of encoding time (tenc ) to reduce T2* signal decay influence during acquisition. METHODS: Radial zGRF -RHE and standard radial UTE were investigated over a range of receiver bandwidths in simulations, phantom and in vivo brain experiments. Central k-space in zGRF -RHE was acquired through single point measurements at the minimum achievable TE. T2* blurring artifacts and image SNR and CNR were assessed. RESULTS: zGRF -RHE enabled 90° flip angle artifact-free excitation, whereas gradient pre-ramping provided greater tenc efficiency for any readout bandwidths. Experiments confirmed simulation results, revealing sharper edge characteristics particularly at short readout durations (TRO ). Significant SNR improvements of up to 4.8% were observed for longer TRO . CONCLUSION: zGRF -RHE allows for artifact-free high flip angle excitation with time-efficient encoding improving on image characteristics. This hybrid encoding concept with gradient pre-ramping is trajectory independent and can be introduced in any center-out UTE trajectory design.


Asunto(s)
Encéfalo/diagnóstico por imagen , Procesamiento de Imagen Asistido por Computador/métodos , Imagen por Resonancia Magnética , Algoritmos , Artefactos , Simulación por Computador , Femenino , Humanos , Aumento de la Imagen/métodos , Interpretación de Imagen Asistida por Computador/métodos , Imagenología Tridimensional , Modelos Estadísticos , Fantasmas de Imagen , Relación Señal-Ruido , Sodio/química
4.
Neuroimage ; 164: 214-229, 2018 01 01.
Artículo en Inglés | MEDLINE | ID: mdl-28286317

RESUMEN

Recent developments in accelerated imaging methods allow faster acquisition of high spatial resolution images. This could improve the applications of functional magnetic resonance imaging at 7 Tesla (7T-fMRI), such as neurosurgical planning and Brain Computer Interfaces (BCIs). However, increasing the spatial and temporal resolution will both lead to signal-to-noise ratio (SNR) losses due to decreased net magnetization per voxel and T1-relaxation effect, respectively. This could potentially offset the SNR efficiency gains made with increasing temporal resolution. We investigated the effects of varying spatial and temporal resolution on fMRI sensitivity measures and their implications on fMRI-based BCI simulations. We compared temporal signal-to-noise ratio (tSNR), observed percent signal change (%∆S), volumes of significant activation, Z-scores and decoding performance of linear classifiers commonly used in BCIs across a range of spatial and temporal resolution images acquired during an ankle-tapping task. Our results revealed an average increase of 22% in %∆S (p=0.006) and 9% in decoding performance (p=0.015) with temporal resolution only at the highest spatial resolution of 1.5×1.5×1.5mm3, despite a 29% decrease in tSNR (p<0.001) and plateaued Z-scores. Further, the volume of significant activation was indifferent (p>0.05) across spatial resolution specifically at the highest temporal resolution of 500ms. These results demonstrate that the overall BOLD sensitivity can be increased significantly with temporal resolution, granted an adequately high spatial resolution with minimal physiological noise level. This shows the feasibility of diffuse motor-network imaging at high spatial and temporal resolution with robust BOLD sensitivity with 7T-fMRI. Importantly, we show that this sensitivity improvement could be extended to an fMRI application such as BCIs.


Asunto(s)
Mapeo Encefálico/métodos , Encéfalo/diagnóstico por imagen , Procesamiento de Imagen Asistido por Computador/métodos , Imagen por Resonancia Magnética/métodos , Red Nerviosa/diagnóstico por imagen , Adulto , Femenino , Humanos , Masculino , Adulto Joven
5.
Hum Brain Mapp ; 39(6): 2635-2650, 2018 06.
Artículo en Inglés | MEDLINE | ID: mdl-29516636

RESUMEN

Performing voluntary movements involves many regions of the brain, but it is unknown how they work together to plan and execute specific movements. We recorded high-resolution ultra-high-field blood-oxygen-level-dependent signal during a cued ankle-dorsiflexion task. The spatiotemporal dynamics and the patterns of task-relevant information flow across the dorsal motor network were investigated. We show that task-relevant information appears and decays earlier in the higher order areas of the dorsal motor network then in the primary motor cortex. Furthermore, the results show that task-relevant information is encoded in general initially, and then selective goals are subsequently encoded in specifics subregions across the network. Importantly, the patterns of recurrent information flow across the network vary across different subregions depending on the goal. Recurrent information flow was observed across all higher order areas of the dorsal motor network in the subregions encoding for the current goal. In contrast, only the top-down information flow from the supplementary motor cortex to the frontoparietal regions, with weakened recurrent information flow between the frontoparietal regions and bottom-up information flow from the frontoparietal regions to the supplementary cortex were observed in the subregions encoding for the opposing goal. We conclude that selective motor goal encoding and execution rely on goal-dependent differences in subregional recurrent information flow patterns across the long-range dorsal motor network areas that exhibit graded functional specialization.


Asunto(s)
Toma de Decisiones/fisiología , Vías Eferentes/fisiología , Objetivos , Actividad Motora/fisiología , Desempeño Psicomotor/fisiología , Adulto , Cuerpo Estriado/diagnóstico por imagen , Vías Eferentes/diagnóstico por imagen , Femenino , Lóbulo Frontal/diagnóstico por imagen , Humanos , Procesamiento de Imagen Asistido por Computador , Imagen por Resonancia Magnética , Masculino , Oxígeno/sangre , Factores de Tiempo , Adulto Joven
6.
Magn Reson Med ; 79(4): 1950-1961, 2018 04.
Artículo en Inglés | MEDLINE | ID: mdl-28752556

RESUMEN

PURPOSE: This work demonstrates a 3D radial multi-echo acquisition scheme for time-efficient sodium (23 Na) MR-signal acquisition and analysis. Echo reconstructions were used to produce signal-to-noise ratio (SNR)-enhanced 23 Na-images and parameter maps of the biexponential observed transverse relaxation time ( T2*) decay. METHODS: A custom-built sequence for radial multi-echo acquisition was proposed for acquisition of a series of 3D volumetric 23 Na-images. Measurements acquired in a phantom and in vivo human brains were analyzed for SNR enhancement and multi-component T2* estimation. RESULTS: Rapid gradient refocused imaging acquired 38 echoes within a repetition time of 160 ms. Signal averaging of multi-echo time (TE) measurements showed an average brain tissue SNR enhancement of 34% compared to single-TE images across subjects. Phantom and in vivo measurements detected distinguishable signal decay characteristics for fluid and solid media. Mapping results were investigated in phantom and in vivo experiments for sequence timing optimization and signal decay analysis. The T2* mapping results were consistent with previously reported values and facilitated fluid-signal discrimination. CONCLUSION: The proposed method offers an efficient 23 Na-imaging scheme that extends existing 23 Na-MRI sequences by acquiring signal decay information with no increase in time or specific absorption rate. The resultant SNR-enhanced 23 Na-images and estimated T2* signal decay characteristics offer great potential for detailed investigation of tissue compartment characterization and clinical application. Magn Reson Med 79:1950-1961, 2018. © 2017 International Society for Magnetic Resonance in Medicine.


Asunto(s)
Procesamiento de Imagen Asistido por Computador/métodos , Imagenología Tridimensional , Imagen por Resonancia Magnética , Fantasmas de Imagen , Isótopos de Sodio/química , Sodio/química , Adulto , Encéfalo/diagnóstico por imagen , Mapeo Encefálico , Femenino , Humanos , Interpretación de Imagen Asistida por Computador , Funciones de Verosimilitud , Masculino , Neuroimagen , Relación Señal-Ruido
7.
MAGMA ; 31(5): 621-632, 2018 Oct.
Artículo en Inglés | MEDLINE | ID: mdl-29845434

RESUMEN

OBJECTIVE: Ultra-high-field functional MRI (UHF-fMRI) allows for higher spatiotemporal resolution imaging. However, higher-resolution imaging entails coverage limitations. Processing partial-coverage images using standard pipelines leads to sub-optimal results. We aimed to develop a simple, semi-automated pipeline for processing partial-coverage UHF-fMRI data using widely used image processing algorithms. MATERIALS AND METHODS: We developed automated pipelines for optimized skull stripping and co-registration of partial-coverage UHF functional images, using built-in functions of the Centre for Functional Magnetic Resonance Imaging of the Brain's (FMRIB's) Software library (FSL) and advanced normalization tools. We incorporated the pipelines into the FSL's functional analysis pipeline and provide a semi-automated optimized partial-coverage functional analysis pipeline (OPFAP). RESULTS: Compared to the standard pipeline, the OPFAP yielded images with 15 and 30% greater volume of non-zero voxels after skull stripping the functional and anatomical images, respectively (all p = 0.0004), which reflected the conservation of cortical voxels lost when the standard pipeline was used. The OPFAP yielded the greatest Dice and Jaccard coefficients (87 and 80%, respectively; all p < 0.0001) between the co-registered participant gyri maps and the template gyri maps, demonstrating the goodness of the co-registration results. Furthermore, the greatest volume of group-level activation in the most number of functionally relevant regions was observed when the OPFAP was used. Importantly, group-level activations were not observed when using the standard pipeline. CONCLUSION: These results suggest that the OPFAP should be used for processing partial-coverage UHF-fMRI data for detecting high-resolution macroscopic blood oxygenation level-dependent activations.


Asunto(s)
Encéfalo/diagnóstico por imagen , Procesamiento de Imagen Asistido por Computador , Imagen por Resonancia Magnética , Neuroimagen , Adulto , Algoritmos , Femenino , Voluntarios Sanos , Humanos , Imagenología Tridimensional , Masculino , Oxígeno/química , Programas Informáticos , Adulto Joven
8.
Magn Reson Med ; 75(6): 2517-25, 2016 06.
Artículo en Inglés | MEDLINE | ID: mdl-26193125

RESUMEN

PURPOSE: Brief bursts of RF noise during MR data acquisition ("k-space spikes") cause disruptive image artifacts, manifesting as stripes overlaid on the image. RF noise is often related to hardware problems, including vibrations during gradient-heavy sequences, such as diffusion-weighted imaging. In this study, we present an application of the Robust Principal Component Analysis (RPCA) algorithm to remove spike noise from k-space. METHODS: Corrupted k-space matrices were decomposed into their low-rank and sparse components using the RPCA algorithm, such that spikes were contained within the sparse component and artifact-free k-space data remained in the low-rank component. Automated center refilling was applied to keep the peaked central cluster of k-space from misclassification in the sparse component. RESULTS: This algorithm was demonstrated to effectively remove k-space spikes from four data types under conditions generating spikes: (i) mouse heart T1 mapping, (ii) mouse heart cine imaging, (iii) human kidney diffusion tensor imaging (DTI) data, and (iv) human brain DTI data. Myocardial T1 values changed by 86.1 ± 171 ms following despiking, and fractional anisotropy values were recovered following despiking of DTI data. CONCLUSION: The RPCA despiking algorithm will be a valuable postprocessing method for retrospectively removing stripe artifacts without affecting the underlying signal of interest. Magn Reson Med 75:2517-2525, 2016. © 2015 The Authors. Magnetic Resonance in Medicine published by Wiley Periodicals, Inc. on behalf of International Society for Magnetic Resonance in Medicine. This is an open access article under the terms of the Creative Commons Attribution License, which permits use, distribution and reproduction in any medium, provided the original work is properly cited.


Asunto(s)
Algoritmos , Imagen de Difusión por Resonancia Magnética/métodos , Corazón/diagnóstico por imagen , Procesamiento de Imagen Asistido por Computador/métodos , Imagen por Resonancia Cinemagnética/métodos , Animales , Artefactos , Encéfalo/diagnóstico por imagen , Humanos , Riñón/diagnóstico por imagen , Ratones , Análisis de Componente Principal , Procesamiento de Señales Asistido por Computador
9.
Magn Reson Med ; 73(2): 731-9, 2015 Feb.
Artículo en Inglés | MEDLINE | ID: mdl-24634098

RESUMEN

PURPOSE: Advanced methodologies for visualizing novel tissue contrast are essential for phenotyping the ever-increasing number of mutant mouse embryos being generated. Although diffusion microscopic MRI (µMRI) has been used to phenotype embryos, widespread routine use is limited by extended scanning times, and there is no established experimental procedure ensuring optimal data acquisition. METHODS: We developed two protocols for designing experimental procedures for diffusion µMRI of mouse embryos, which take into account the effect of embryo preparation and pulse sequence parameters on resulting data. We applied our protocols to an investigation of the splotch mouse model as an example implementation. RESULTS: The protocols provide DTI data in 24 min per direction at 75 µm isotropic using a three-dimensional fast spin-echo sequence, enabling preliminary imaging in 3 h (6 directions plus one unweighted measurement), or detailed imaging in 9 h (42 directions plus six unweighted measurements). Application to the splotch model enabled assessment of spinal cord pathology. CONCLUSION: We present guidelines for designing diffusion µMRI experiments, which may be adapted for different studies and research facilities. As they are suitable for routine use and may be readily implemented, we hope they will be adopted by the phenotyping community.


Asunto(s)
Imagen de Difusión por Resonancia Magnética/métodos , Embrión de Mamíferos/citología , Imagen por Resonancia Magnética/métodos , Microscopía/métodos , Médula Espinal/citología , Médula Espinal/embriología , Animales , Aumento de la Imagen/métodos , Ratones , Ratones Endogámicos C57BL , Ratones Transgénicos , Factor de Transcripción PAX3 , Factores de Transcripción Paired Box/genética , Diagnóstico Prenatal/métodos , Reproducibilidad de los Resultados , Sensibilidad y Especificidad , Manejo de Especímenes/métodos
10.
Magn Reson Med ; 69(1): 238-47, 2013 Jan.
Artículo en Inglés | MEDLINE | ID: mdl-22411842

RESUMEN

MRI is important for the assessment of cardiac structure and function in preclinical studies of cardiac disease. Arterial spin labeling techniques can be used to measure perfusion noninvasively. In this study, an electrocardiogram-gated Look-Locker sequence with segmented k-space acquisition has been implemented to acquire single slice arterial spin labeling data sets in 15 min in the mouse heart. A data logger was introduced to improve data quality by: (1) allowing automated rejection of respiration-corrupted images, (2) providing additional prospective gating to improve consistency of acquisition timing, and (3) allowing the recombination of uncorrupted k-space lines from consecutive data sets to reduce respiration corruption. Finally, variability and repeatability of perfusion estimation within-session, between-session, between-animal, and between image rejection criteria were assessed in mice. The criterion used to reject images from the T(1) fit was shown to affect the perfusion estimation. These data showed that the between-animal coefficient of variability (24%) was greater than the between-session variability (17%) and within-session variability (11%). Furthermore, the magnitude of change in perfusion required to detect differences was 30% (within-session) and 55% (between-session) according to Bland-Altman repeatability analysis. These technique developments and repeatability statistics will provide a platform for future preclinical studies applying cardiac arterial spin labeling.


Asunto(s)
Circulación Coronaria , Electrocardiografía , Imagen por Resonancia Magnética/métodos , Animales , Procesamiento de Imagen Asistido por Computador , Ratones , Marcadores de Spin
11.
Magn Reson Med ; 70(4): 1125-36, 2013 Oct.
Artículo en Inglés | MEDLINE | ID: mdl-23168945

RESUMEN

PURPOSE: Myocardial blood flow (MBF) is an important indicator of cardiac tissue health, which can be measured using arterial spin labeling. This study aimed to develop a new method of MBF quantification with blood pool magnetization measurement ("bpMBF quantification") that allows multislice cardiac arterial spin labeling. THEORY AND METHODS: A multislice segmented ECG-gated Look-Locker T1 mapping sequence was validated. Quantification of multislice arterial spin labeling is not straightforward due to the large volume of blood inverted following slice-selective inversion. For bpMBF quantification, a direct measurement of the left-ventricle blood pool magnetization was used to approximate the blood input function into the Bloch equations. Simulations and in vivo measurements in the mouse heart were performed to evaluate the bpMBF method. RESULTS: Measurements indicated that blood pool magnetization requires ∼3 s to return to equilibrium following slice-selective inversion. Simulation and in vivo results show that bpMBF quantification is robust to variations in slice-selective thickness and therefore applicable to multislice acquisition, whereas traditional methods are likely to underestimate multislice perfusion. In vivo, single and multislice perfusion values matched well when quantified using bpMBF. CONCLUSION: The first multislice cardiac arterial spin labeling technique has been presented, which can be used for accurate perfusion measurements in studies of cardiac disease.


Asunto(s)
Circulación Coronaria/fisiología , Vasos Coronarios/fisiología , Aumento de la Imagen/métodos , Interpretación de Imagen Asistida por Computador/métodos , Angiografía por Resonancia Magnética/métodos , Imagen por Resonancia Cinemagnética/métodos , Imagen de Perfusión Miocárdica/métodos , Algoritmos , Animales , Vasos Coronarios/anatomía & histología , Ratones , Reproducibilidad de los Resultados , Sensibilidad y Especificidad , Marcadores de Spin
12.
Int J Neuropsychopharmacol ; 16(8): 1695-706, 2013 Sep.
Artículo en Inglés | MEDLINE | ID: mdl-23473040

RESUMEN

Transcranial direct current stimulation is an emerging treatment for brain disorders but its mode of action is not well understood. We applied 10 min 1 mA anodal transcranial direct current stimulation (tDCS) inside the bore of a 3 T MRI scanner to the left dorsolateral prefrontal cortex of 13 healthy volunteers (aged 19-28 yr) in a blinded, sham-controlled, cross-over design. Brain bioenergetics were measured from the left temporo-frontal region using 31P magnetic resonance spectroscopy before, during and for 20 min following tDCS. Brain pH rose during tDCS and remained elevated afterwards. Phosphomonoesters were significantly decreased while inorganic phosphate (Pi) also fell. Partial-least squares discriminant analysis of the data revealed two significantly different subject groups: one where phosphocreatine (PCr), ATP and Pi fell along with a larger increase in pH and one where PCr and ATP increased along with a smaller increase in pH and a slower and more sustained decrease in Pi. Group membership was predicted by baseline pH and ATP. We interpreted the effects of tDCS as driving two biochemical processes: cellular consumption of ATP causing hydrolysis of PCr via the creatine kinase reaction driving the increase in pH; synthesis of ATP and PCr by mitochondria with concomitant drop in Pi and phosphomonoester levels.


Asunto(s)
Metabolismo Energético/fisiología , Corteza Prefrontal/fisiología , Estimulación Magnética Transcraneal , Adenosina Trifosfato/metabolismo , Adulto , Ondas Encefálicas/fisiología , Estudios Cruzados , Análisis Discriminante , Método Doble Ciego , Electrodos , Electroencefalografía , Femenino , Lateralidad Funcional , Humanos , Concentración de Iones de Hidrógeno , Espectroscopía de Resonancia Magnética , Masculino , Análisis Multivariante , Fosfatos/metabolismo , Fosfocreatina/metabolismo , Isótopos de Fósforo/metabolismo , Adulto Joven
13.
Neuroimage ; 56(3): 974-83, 2011 Jun 01.
Artículo en Inglés | MEDLINE | ID: mdl-21310249

RESUMEN

Extensive worldwide efforts are underway to produce knockout mice for each of the ~25,000 mouse genes, which may give new insights into the underlying pathophysiology of neurological disease. Microscopic magnetic resonance imaging (µMRI) is a key method for non-invasive morphological phenotyping, capable of producing high-resolution 3D images of ex-vivo brains, after fixation with an MR contrast agent. These agents have been suggested to act as active-stains, enhancing structures not normally visible on MRI. In this study, we investigated the structural correlates of the MRI agent Gd-DTPA, together with the optimal preparation and scan parameters for contrast-enhanced gradient-echo imaging of the mouse brain. We observed that in-situ preparation was preferential to ex-situ due to the degree of extraction damage. In-situ brains scanned with optimised parameters, enabled images with a high signal-to-noise-ratio (SNR ~30) and comprehensive anatomical delineation. Direct correlation of the MR brain structures to histology, detailed fine histoarchitecture in the cortex, cerebellum, olfactory bulb and hippocampus. Neurofilament staining demonstrated that regions of negative MR contrast strongly correlated to myelinated white-matter structures, whilst structures of more positive MR contrast corresponded to areas with high grey matter content. We were able to identify many sub-regions, particularly within the hippocampus, such as the unmyelinated mossy fibres (stratum lucidum) and their region of synapse in the stratum pyramidale, together with the granular layer of the dentate gyrus, an area of densely packed cell bodies, which was clearly visible as a region of hyperintensity. This suggests that cellular structure influences the site-specific distribution of the MR contrast agent, resulting in local variations in T(2)*, which leads to enhanced tissue discrimination. Our findings provide insights not only into the cellular distribution and mechanism of MR active-staining, but also allow for three dimensional analysis, which enables interpretation of magnetic resonance microscopy brain data and highlights cellular structure for investigation of disease processes in development and disease.


Asunto(s)
Encéfalo/anatomía & histología , Animales , Cerebelo/anatomía & histología , Corteza Cerebral/anatomía & histología , Imagen Eco-Planar , Femenino , Procesamiento de Imagen Asistido por Computador , Inmunohistoquímica , Imagen por Resonancia Magnética , Masculino , Ratones , Ratones Endogámicos C57BL , Perfusión , Coloración y Etiquetado , Tálamo/anatomía & histología , Fijación del Tejido
14.
Neuroimage ; 54(2): 769-78, 2011 Jan 15.
Artículo en Inglés | MEDLINE | ID: mdl-20656039

RESUMEN

Ambitious international efforts are underway to produce gene-knockout mice for each of the 25,000 mouse genes, providing a new platform to study mammalian development and disease. Robust, large-scale methods for morphological assessment of prenatal mice will be essential to this work. Embryo phenotyping currently relies on histological techniques but these are not well suited to large volume screening. The qualitative nature of these approaches also limits the potential for detailed group analysis. Advances in non-invasive imaging techniques such as magnetic resonance imaging (MRI) may surmount these barriers. We present a high-throughput approach to generate detailed virtual histology of the whole embryo, combined with the novel use of a whole-embryo atlas for automated phenotypic assessment. Using individual 3D embryo MRI histology, we identified new pituitary phenotypes in Hesx1 mutant mice. Subsequently, we used advanced computational techniques to produce a whole-body embryo atlas from 6 CD-1 embryos, creating an average image with greatly enhanced anatomical detail, particularly in CNS structures. This methodology enabled unsupervised assessment of morphological differences between CD-1 embryos and Chd7 knockout mice (n=5 Chd7(+/+) and n=8 Chd7(+/-), C57BL/6 background). Using a new atlas generated from these three groups, quantitative organ volumes were automatically measured. We demonstrated a difference in mean brain volumes between Chd7(+/+) and Chd7(+/-) mice (42.0 vs. 39.1mm(3), p<0.05). Differences in whole-body, olfactory and normalised pituitary gland volumes were also found between CD-1 and Chd7(+/+) mice (C57BL/6 background). Our work demonstrates the feasibility of combining high-throughput embryo MRI with automated analysis techniques to distinguish novel mouse phenotypes.


Asunto(s)
Atlas como Asunto , Embrión de Mamíferos/anatomía & histología , Ensayos Analíticos de Alto Rendimiento/métodos , Imagenología Tridimensional/métodos , Imagen por Resonancia Magnética/métodos , Interfaz Usuario-Computador , Animales , Proteínas de Unión al ADN/deficiencia , Proteínas de Unión al ADN/genética , Técnicas Histológicas , Ratones , Ratones Endogámicos C57BL , Ratones Noqueados , Fenotipo
15.
Magn Reson Med ; 65(1): 60-70, 2011 Jan.
Artículo en Inglés | MEDLINE | ID: mdl-20740650

RESUMEN

MRI has become an important tool to noninvasively assess global and regional cardiac function, infarct size, or myocardial blood flow in surgically or genetically modified mouse models of human heart disease. Constraints on scan time due to sensitivity to general anesthesia in hemodynamically compromised mice frequently limit the number of parameters available in one imaging session. Parallel imaging techniques to reduce acquisition times require coil arrays, which are technically challenging to design at ultrahigh magnetic field strengths. This work validates the use of an eight-channel volume phased-array coil for cardiac MRI in mice at 9.4 T. Two- and three-dimensional sequences were combined with parallel imaging techniques and used to quantify global cardiac function, T(1)-relaxation times and infarct sizes. Furthermore, the rapid acquisition of functional cine-data allowed for the first time in mice measurement of left-ventricular peak filling and ejection rates under intravenous infusion of dobutamine. The results demonstrate that a threefold accelerated data acquisition is generally feasible without compromising the accuracy of the results. This strategy may eventually pave the way for routine, multiparametric phenotyping of mouse hearts in vivo within one imaging session of tolerable duration.


Asunto(s)
Aumento de la Imagen/instrumentación , Imagen por Resonancia Cinemagnética/instrumentación , Imagen por Resonancia Cinemagnética/veterinaria , Magnetismo/instrumentación , Transductores , Animales , Diseño de Equipo , Análisis de Falla de Equipo , Ratones , Ratones Endogámicos C57BL , Reproducibilidad de los Resultados , Sensibilidad y Especificidad
16.
Brain ; 133(Pt 3): 858-67, 2010 Mar.
Artículo en Inglés | MEDLINE | ID: mdl-20123726

RESUMEN

Multiple sclerosis is an inflammatory, degenerative disease of the central nervous system. The most obvious pathological change in multiple sclerosis is multifocal demyelination of the white matter, but grey matter demyelination may be of equal or even greater importance for its clinical manifestations. In order to assess the pathogenetic role of lesions in the grey and white matter, and to explore the association between demyelinated and non-lesional brain tissue, tools are needed to depict each of these tissue components accurately in vivo. Due to its sensitivity in detecting white matter lesions, T(2)-weighted magnetic resonance imaging at 1.5 T is important in the diagnosis of multiple sclerosis. However, magnetic resonance imaging at 1.5 T largely fails to detect grey matter lesions. In this study, we used T(2)-weighted magnetic resonance imaging at 9.4 T to detect grey matter lesions in fixed post-mortem multiple sclerosis motor cortex. Furthermore, we produced T(1), T(2) and magnetization transfer ratio maps, and correlated these indices with quantitative histology [neuronal density, intensity of immunostaining for myelin basic protein (reflecting myelin content) and phosphorylated neurofilament (reflecting axonal area)] using t-tests and multivariate regression. In 21 tissue samples, 28 cortical grey matter lesions were visible on both T(2)-weighted magnetic resonance imaging and sections immunostained for myelin basic protein, 15/28 being mixed white and grey matter and 11/28 subpial cortical grey matter lesions; 2/28 cortical grey matter lesions involved all layers of the cortex. Compared with non-lesional cortex, cortical grey matter lesions showed reduction of neuronal density (98/mm(2), SD = 34/mm(2;) versus 129/mm(2), SD = 44; P < 0.01), phosphorylated neurofilament (1/transmittance = 1.16; SD = 0.09 versus 1.24; SD = 0.1; P < 0.01) and magnetization transfer ratio (31.1 pu; SD = 11.9 versus 37.5 pu; SD = 8.7; P = 0.01), and an increase of T(2) (25.9; SD = 5 versus 22.6 ms; SD = 4.7; P < 0.01). Associations were detected between phosphorylated neurofilament and myelin basic protein (r = 0.58, P < 0.01), myelin basic protein and T(2) (r = -0.59, P < 0.01), and neuronal density and T(1) (r = -0.57, P < 0.01). All indices correlated with duration of tissue fixation, however, including the latter in the analysis did not fundamentally affect the associations described. Our data show that T(2)-weighted magnetic resonance imaging at 9.4 T enables detection of cortical grey matter lesion in post-mortem multiple sclerosis brain. The quantitative associations suggest that in cortical grey matter T(1) may be a predictor of neuronal density, and T(2) of myelin content (and-secondarily-axons). Successful translation of these results into in vivo studies using high field magnetic resonance imaging (e.g. 3 T and 7 T) will improve the assessment of cortical pathology and thereby have an impact on the diagnosis and natural history studies of patients with multiple sclerosis, as well as clinical trial designs for putative treatments to prevent cortical demyelination and neuronal loss.


Asunto(s)
Corteza Motora/patología , Esclerosis Múltiple/patología , Fibras Nerviosas Amielínicas/patología , Recuento de Células , Humanos , Imagen por Resonancia Magnética/instrumentación , Imagen por Resonancia Magnética/métodos , Persona de Mediana Edad , Corteza Motora/metabolismo , Esclerosis Múltiple/metabolismo , Análisis Multivariante , Proteína Básica de Mielina , Fibras Nerviosas Mielínicas/metabolismo , Fibras Nerviosas Mielínicas/patología , Fibras Nerviosas Amielínicas/metabolismo , Proteínas del Tejido Nervioso/metabolismo , Proteínas de Neurofilamentos/metabolismo , Neuronas/metabolismo , Neuronas/patología , Fosforilación , Análisis de Regresión , Factores de Transcripción/metabolismo
17.
Transl Vis Sci Technol ; 10(2): 8, 2021 02 05.
Artículo en Inglés | MEDLINE | ID: mdl-34003892

RESUMEN

Purpose: We aimed to image the optic nerve, subarachnoid space and optic nerve sheath in emmetropes and myopes ultra-high field (7-Tesla) magnetic resonance imaging (MRI). We targeted the retrobulbar distance of approximately 3 mm behind the eyeball, an area of clinical interest because of optic nerve sheath distensibility and pressure-related enlargement. Methods: Eleven emmetropes (+0.75 to -0.50D, aged 20-41 years) and 10 myopes (-4.5 to -12D, aged 21-37 years) participated. Cross-sectional area of the optic nerve, subarachnoid space and optic nerve sheath at approximately 3 mm behind the eye were measured from two-dimensional T2-weighted coronal oblique MRI images obtained through the left optic nerve. Axial length of the left eye was measured from T2-weighted axial MRI images. In nine emmetropes and seven myopes, the optic nerve head was imaged with optical coherence tomography to compare retrobulbar and intraocular measures. Results: Retrobulbar optic nerve, subarachnoid space and optic nerve sheath dimensions differed between myopes and emmetropes. Myopes tended to have smaller optic nerve and subarachnoid space. Longer MRI-derived axial length was associated with smaller optic nerve area (P = 0.03). Bruch's membrane opening area did not predict retrobulbar optic nerve area (P = 0.48). Conclusions: This study demonstrates the feasibility of using 7-Tesla MRI to measure optic nerve, subarachnoid space, and optic nerve sheath dimensions behind the eye. In healthy adults, the retrobulbar optic nerve and subarachnoid space size are influenced by the degree of myopia. Translational Relevance: ultra-high field MRI is a practical tool for assessing the morphometry of the optic nerve and surrounding anatomy behind the eye.


Asunto(s)
Emetropía , Miopía , Adulto , Humanos , Imagen por Resonancia Magnética , Miopía/diagnóstico por imagen , Nervio Óptico/diagnóstico por imagen , Espacio Subaracnoideo/diagnóstico por imagen
18.
Magn Reson Imaging Clin N Am ; 29(1): 103-116, 2021 Feb.
Artículo en Inglés | MEDLINE | ID: mdl-33237011

RESUMEN

Ultrahigh-field (7T) MRI provides improved contrast and a signal-to-noise gain compared with lower magnetic field strengths. Here, we demonstrate feasibility and optimization of anatomic imaging of the eye and orbit using a dedicated commercial multichannel transmit and receive eye coil. Optimization of participant setup techniques and MRI sequence parameters allowed for improvements in the image resolution and contrast, and the eye and orbit coverage with minimal susceptibility and motion artifacts in a clinically feasible protocol.


Asunto(s)
Imagen por Resonancia Magnética/métodos , Órbita/anatomía & histología , Adulto , Femenino , Humanos , Masculino , Valores de Referencia , Adulto Joven
19.
Neuroimage ; 49(1): 379-90, 2010 Jan 01.
Artículo en Inglés | MEDLINE | ID: mdl-19651221

RESUMEN

In epilepsy patients who have electrodes implanted in their brains as part of their pre-surgical assessment, simultaneous intracranial EEG and fMRI (icEEG-fMRI) may provide important localising information and improve understanding of the underlying neuropathology. However, patient safety during icEEG-fMRI has not been addressed. Here the potential health hazards associated with icEEG-fMRI were evaluated theoretically and the main risks identified as: mechanical forces on electrodes from transient magnetic effects, tissue heating due to interaction with the pulsed RF fields and tissue stimulation due to interactions with the switched magnetic gradient fields. These potential hazards were examined experimentally in vitro on a Siemens 3 T Trio, 1.5 T Avanto and a GE 3 T Signa Excite scanner using a Brain Products MR compatible EEG system. No electrode flexion was observed. Temperature measurements demonstrated that heating well above guideline limits can occur. However heating could be kept within safe limits (<1.0 degrees C) by using a head transmit RF coil, ensuring EEG cable placement to exit the RF coil along its central z-axis, using specific EEG cable lengths and limiting MRI sequence specific absorption rates (SARs). We found that the risk of tissue damage due to RF-induced heating is low provided implant and scanner specific SAR limits are observed with a safety margin used to account for uncertainties (e.g. in scanner-reported SAR). The observed scanner gradient switching induced current (0.08 mA) and charge density (0.2 microC/cm(2)) were well within safety limits (0.5 mA and 30 microC/cm(2), respectively). Site-specific testing and a conservative approach to safety are required to avoid the risk of adverse events.


Asunto(s)
Encéfalo/patología , Encéfalo/fisiopatología , Electroencefalografía/efectos adversos , Electroencefalografía/métodos , Imagen por Resonancia Magnética/efectos adversos , Imagen por Resonancia Magnética/métodos , Algoritmos , Electrodos Implantados , Electroencefalografía/instrumentación , Campos Electromagnéticos/efectos adversos , Estudios de Factibilidad , Humanos , Imagen por Resonancia Magnética/instrumentación , Temperatura
20.
Magn Reson Med ; 63(4): 1111-8, 2010 Apr.
Artículo en Inglés | MEDLINE | ID: mdl-20373414

RESUMEN

Continuous arterial spin labeling (CASL) measurements over a range of post-labeling delay (PLD) times can be interpreted to estimate cerebral blood flow (CBF) and arterial transit time (deltaa) with good spatial and temporal resolution. In this work, we present an in vivo demonstration of Hadamard-encoded continuous arterial spin labeling (H-CASL); an efficient method of imaging the inflow of short boli of labeled blood water in the brain at multiple PLD times. We present evidence that H-CASL is viable for in vivo application in the rat brain and can improve the precision of deltaa estimation in 2/3 of the imaging time required for standard multi-PLD CASL. Based on these findings, we propose that H-CASL may have application as an efficient prescan for optimization of ASL imaging parameters to improve the precision of CBF estimation.


Asunto(s)
Circulación Cerebrovascular/fisiología , Imagen por Resonancia Magnética/métodos , Marcadores de Spin , Algoritmos , Animales , Velocidad del Flujo Sanguíneo/fisiología , Simulación por Computador , Procesamiento de Imagen Asistido por Computador , Imagen por Resonancia Magnética/instrumentación , Masculino , Ratas , Ratas Sprague-Dawley , Técnica de Sustracción