Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 59
Filtrar
Más filtros

Bases de datos
País/Región como asunto
Tipo del documento
Intervalo de año de publicación
1.
Childs Nerv Syst ; 2024 Apr 20.
Artículo en Inglés | MEDLINE | ID: mdl-38642113

RESUMEN

BACKGROUND: Texture analysis extracts many quantitative image features, offering a valuable, cost-effective, and non-invasive approach for individual medicine. Furthermore, multimodal machine learning could have a large impact for precision medicine, as texture biomarkers can underlie tissue microstructure. This study aims to investigate imaging-based biomarkers of radio-induced neurotoxicity in pediatric patients with metastatic medulloblastoma, using radiomic and dosiomic analysis. METHODS: This single-center study retrospectively enrolled children diagnosed with metastatic medulloblastoma (MB) and treated with hyperfractionated craniospinal irradiation (CSI). Histological confirmation of medulloblastoma and baseline follow-up magnetic resonance imaging (MRI) were mandatory. Treatment involved helical tomotherapy (HT) delivering a dose of 39 Gray (Gy) to brain and spinal axis and a posterior fossa boost up to 60 Gy. Clinical outcomes, such as local and distant brain control and neurotoxicity, were recorded. Radiomic and dosiomic features were extracted from tumor regions on T1, T2, FLAIR (fluid-attenuated inversion recovery) MRI-maps, and radiotherapy dose distribution. Different machine learning feature selection and reduction approaches were performed for supervised and unsupervised clustering. RESULTS: Forty-eight metastatic medulloblastoma patients (29 males and 19 females) with a mean age of 12 ± 6 years were enrolled. For each patient, 332 features were extracted. Greater level of abstraction of input data by combining selection of most performing features and dimensionality reduction returns the best performance. The resulting one-component radiomic signature yielded an accuracy of 0.73 with sensitivity, specificity, and precision of 0.83, 0.64, and 0.68, respectively. CONCLUSIONS: Machine learning radiomic-dosiomic approach effectively stratified pediatric medulloblastoma patients who experienced radio-induced neurotoxicity. Strategy needs further validation in external dataset for its potential clinical use in ab initio management paradigms of medulloblastoma.

2.
J Appl Clin Med Phys ; 23(3): e13507, 2022 Mar.
Artículo en Inglés | MEDLINE | ID: mdl-35064746

RESUMEN

PURPOSE: This retrospective work aims to evaluate the possible impact on intra- and inter-observer variability, contouring time, and contour accuracy of introducing a pelvis computed tomography (CT) auto-segmentation tool in radiotherapy planning workflow. METHODS: Tests were carried out on five structures (bladder, rectum, pelvic lymph-nodes, and femoral heads) of six previously treated subjects, enrolling five radiation oncologists (ROs) to manually re-contour and edit auto-contours generated with a male pelvis CT atlas created with the commercial software MIM MAESTRO. The ROs first delineated manual contours (M). Then they modified the auto-contours, producing automatic-modified (AM) contours. The procedure was repeated to evaluate intra-observer variability, producing M1, M2, AM1, and AM2 contour sets (each comprising 5 structures × 6 test patients × 5 ROs = 150 contours), for a total of 600 contours. Potential time savings was evaluated by comparing contouring and editing times. Structure contours were compared to a reference standard by means of Dice similarity coefficient (DSC) and mean distance to agreement (MDA), to assess intra- and inter-observer variability. To exclude any automation bias, ROs evaluated both M and AM sets as "clinically acceptable" or "to be corrected" in a blind test. RESULTS: Comparing AM to M sets, a significant reduction of both inter-observer variability (p < 0.001) and contouring time (-45% whole pelvis, p < 0.001) was obtained. Intra-observer variability reduction was significant only for bladder and femoral heads (p < 0.001). The statistical test showed no significant bias. CONCLUSION: Our atlas-based workflow proved to be effective for clinical practice as it can improve contour reproducibility and generate time savings. Based on these findings, institutions are encouraged to implement their auto-segmentation method.


Asunto(s)
Planificación de la Radioterapia Asistida por Computador , Tomografía Computarizada por Rayos X , Humanos , Masculino , Variaciones Dependientes del Observador , Pelvis/diagnóstico por imagen , Planificación de la Radioterapia Asistida por Computador/métodos , Reproducibilidad de los Resultados , Estudios Retrospectivos
3.
J Appl Clin Med Phys ; 22(4): 52-62, 2021 Apr.
Artículo en Inglés | MEDLINE | ID: mdl-33735491

RESUMEN

PURPOSE: Patient-specific quality assurance (QA) is very important in radiotherapy, especially for patients with highly conformed treatment plans like VMAT plans. Traditional QA protocols for these plans are time-consuming reducing considerably the time available for patient treatments. In this work, a new MC-based secondary dose check software (SciMoCa) is evaluated and benchmarked against well-established TPS (Monaco and Pinnacle3 ) by means of treatment plans and dose measurements. METHODS: Fifty VMAT plans have been computed using same calculation parameters with SciMoCa and the two primary TPSs. Plans were validated with measurements performed with a 3D diode detector (ArcCHECK) by translating patient plans to phantom geometry. Calculation accuracy was assessed by measuring point dose differences and gamma passing rates (GPR) from a 3D gamma analysis with 3%-2 mm criteria. Comparison between SciMoCa and primary TPS calculations was made using the same estimators and using both patient and phantom geometry plans. RESULTS: TPS and SciMoCa calculations were found to be in very good agreement with validation measurements with average point dose differences of 0.7 ± 1.7% and -0.2 ± 1.6% for SciMoCa and two TPSs, respectively. Comparison between SciMoCa calculations and the two primary TPS plans did not show any statistically significant difference with average point dose differences compatible with zero within error for both patient and phantom geometry plans and GPR (98.0 ± 3.0% and 99.0 ± 3.0% respectively) well in excess of the typical 95 % clinical tolerance threshold. CONCLUSION: This work presents results obtained with a significantly larger sample than other similar analyses and, to the authors' knowledge, compares SciMoCa with a MC-based TPS for the first time. Results show that a MC-based secondary patient-specific QA is a clinically viable, reliable, and promising technique, that potentially allows significant time saving that can be used for patient treatment and a per-plan basis QA that effectively complements traditional commissioning and calibration protocols.


Asunto(s)
Planificación de la Radioterapia Asistida por Computador , Radioterapia de Intensidad Modulada , Algoritmos , Humanos , Mónaco , Método de Montecarlo , Fantasmas de Imagen , Garantía de la Calidad de Atención de Salud , Dosificación Radioterapéutica
4.
J Appl Clin Med Phys ; 21(6): 114-120, 2020 Jun.
Artículo en Inglés | MEDLINE | ID: mdl-32275353

RESUMEN

PURPOSE: To develop and validate a robust template for VMAT SBRT of lung lesions, using the multicriterial optimization (MCO) of a commercial treatment planning system. METHODS: The template was established and refined on 10 lung SBRT patients planned for 55 Gy/5 fr. To improve gradient and conformity a ring structure around the planning target volume (PTV) was set in the list of objectives. Ideal fluence optimization was conducted giving priority to organs at risk (OARs) and using the MCO, which further pushes OARs doses. Segmentation was conducted giving priority to PTV coverage. Two different templates were produced with different degrees of modulation, by setting the Fluence Smoothing parameter to Medium (MFS) and High (HFS). Each template was applied on 20 further patients. Automatic and manual plans were compared in terms of dosimetric parameters, delivery time, and complexity. Statistical significance of differences was evaluated using paired two-sided Wilcoxon signed-rank test. RESULTS: No statistically significant differences in PTV coverage and maximum dose were observed, while an improvement was observed in gradient and conformity. A general improvement in dose to OARs was seen, which resulted to be significant for chest wall V30 Gy , total lung V20 Gy , and spinal cord D0.1 cc . MFS plans are characterized by a higher modulation and longer delivery time than manual plans. HFS plans have a modulation and a delivery time comparable to manual plans, but still present an advantage in terms of gradient. CONCLUSION: The automation of the planning process for lung SBRT using robust templates and MCO was demonstrated to be feasible and more efficient.


Asunto(s)
Carcinoma de Pulmón de Células no Pequeñas , Neoplasias Pulmonares , Radiocirugia , Radioterapia de Intensidad Modulada , Carcinoma de Pulmón de Células no Pequeñas/cirugía , Femenino , Humanos , Pulmón/diagnóstico por imagen , Pulmón/cirugía , Neoplasias Pulmonares/radioterapia , Neoplasias Pulmonares/cirugía , Masculino , Órganos en Riesgo , Dosificación Radioterapéutica , Planificación de la Radioterapia Asistida por Computador
5.
J Appl Clin Med Phys ; 21(12): 219-230, 2020 Dec.
Artículo en Inglés | MEDLINE | ID: mdl-33236827

RESUMEN

PURPOSE: The aim of this work was to establish a methodological approach for creation and optimization of an atlas for auto-contouring, using the commercial software MIM MAESTRO (MIM Software Inc. Cleveland OH). METHODS: A computed tomography (CT) male pelvis atlas was created and optimized to evaluate how different tools and options impact on the accuracy of automatic segmentation. Pelvic lymph nodes (PLN), rectum, bladder, and femurs of 55 subjects were reviewed for consistency by a senior consultant radiation oncologist with 15 yr of experience. Several atlas and workflow options were tuned to optimize the accuracy of auto-contours. The deformable image registration (DIR), the finalization method, the k number of atlas best matching subjects, and several post-processing options were studied. To test our atlas performances, automatic and reference manual contours of 20 test subjects were statistically compared based on dice similarity coefficient (DSC) and mean distance to agreement (MDA) indices. The effect of field of view (FOV) reduction on auto-contouring time was also investigated. RESULTS: With the optimized atlas and workflow, DSC and MDA median values of bladder, rectum, PLN, and femurs were 0.91 and 1.6 mm, 0.85 and 1.6 mm, 0.85 and 1.8 mm, and 0.96 and 0.5 mm, respectively. Auto-contouring time was more than halved by strictly cropping the FOV of the subject to be contoured to the pelvic region. CONCLUSION: A statistically significant improvement of auto-contours accuracy was obtained using our atlas and optimized workflow instead of the MIM Software pelvic atlas.


Asunto(s)
Planificación de la Radioterapia Asistida por Computador , Tomografía Computarizada por Rayos X , Humanos , Masculino , Pelvis/diagnóstico por imagen , Recto , Programas Informáticos
6.
Omega (Westport) ; 82(1): 63-91, 2020 Nov.
Artículo en Inglés | MEDLINE | ID: mdl-30278821

RESUMEN

Traditional models of palliative care are largely inaccessible to homeless persons, and their preferences regarding end-of-life care are poorly understood. The purpose of the present scoping review is to summarize the burgeoning gray and academic literature on end-of-life care for homeless persons. Five medical databases, seven social science databases, and four gray literature databases were searched, resulting in 57 relevant titles. Six themes emerged: (a) Characteristics of homeless persons who require end-of-life care; (b) preferences and concerns of homeless persons approaching the end of life; (c) the role of spirituality for homeless persons at the end of life; (d) barriers to care at the patient, provider, and institutional or structural levels; (e) inclusive models of palliative care; and (f) implications for policy and practice. Practitioners and homeless persons must negotiate many obstacles in the provision and receipt of palliative care. However, there is tremendous potential and opportunity to improve the quality of life at the end of life for this vulnerable population.


Asunto(s)
Muerte , Accesibilidad a los Servicios de Salud , Personas con Mala Vivienda , Femenino , Humanos , Masculino
7.
Strahlenther Onkol ; 195(1): 43-51, 2019 Jan.
Artículo en Inglés | MEDLINE | ID: mdl-30406290

RESUMEN

BACKGROUND AND PURPOSE: In our institute, breast cancer patients undergoing adjuvant treatment are included in a protocol aimed to reduce cardiovascular morbidity (SAFE-2014, NCT2236806), assessing preclinical heart damage with heart speckle-tracking ultrasound. To develop a dose constraint related to subclinical heart damage, a reliable delineation of heart substructures based on a pre-existing guideline was made. PATIENTS AND METHODS: Heart substructures of 16 left-sided breast cancer patients included in the SAFE protocol were delineated by five operators. For each substructure, a multi-contour delineation based on a majority vote algorithm (MCD) was created. A consensus-based delineation (CBD) was developed by an independent team of two blinded operators. Dice similarity coefficients (DSC) between volumes delineated by different operators and the MCD were collected and reported, as well as DSC between CBD and MCD. RESULTS: Mean DSCs between heart chambers delineated by each operator and the corresponding MCDs ranged between 0.78 and 0.96. Mean DSC between substructures delineated by all single operators and the corresponding MCD ranged between 0.84 and 0.94. Mean DSC between CBD and the corresponding MCD ranged from 0.89 to 0.97. CONCLUSION: Results showed low inter-observer variability of heart substructure delineation. This constitutes an external validation of the contouring atlas used, allowing a reliable dosimetric assessment of these volumes within the SAFE-2014 trial.


Asunto(s)
Bisoprolol/administración & dosificación , Adhesión a Directriz , Corazón , Traumatismos por Radiación/prevención & control , Radioterapia Adyuvante/métodos , Ramipril/administración & dosificación , Neoplasias de Mama Unilaterales/radioterapia , Algoritmos , Cardiotónicos/administración & dosificación , Quimioterapia Adyuvante/métodos , Terapia Combinada/métodos , Quimioterapia Combinada , Ecocardiografía Doppler/métodos , Femenino , Corazón/efectos de los fármacos , Corazón/efectos de la radiación , Humanos , Variaciones Dependientes del Observador , Garantía de la Calidad de Atención de Salud , Traumatismos por Radiación/diagnóstico por imagen , Radiometría/métodos , Reproducibilidad de los Resultados , Neoplasias de Mama Unilaterales/tratamiento farmacológico
8.
J Appl Clin Med Phys ; 20(4): 75-82, 2019 Apr.
Artículo en Inglés | MEDLINE | ID: mdl-30924286

RESUMEN

A quantitative evaluation of the performances of the deformable image registration (DIR) algorithm implemented in MIM-Maestro was performed using multiple similarity indices. Two phantoms, capable of mimicking different anatomical bending and tumor shrinking were built and computed tomography (CT) studies were acquired after applying different deformations. Three different contrast levels between internal structures were artificially created modifying the original CT values of one dataset. DIR algorithm was applied between datasets with increasing deformations and different contrast levels and manually refined with the Reg Refine tool. DIR algorithm ability in reproducing positions, volumes, and shapes of deformed structures was evaluated using similarity indices such as: landmark distances, Dice coefficients, Hausdorff distances, and maximum diameter differences between segmented structures. Similarity indices values worsen with increasing bending and volume difference between reference and target image sets. Registrations between images with low contrast (40 HU) obtain scores lower than those between images with high contrast (970 HU). The use of Reg Refine tool leads generally to an improvement of similarity parameters values, but the advantage is generally less evident for images with low contrast or when structures with large volume differences are involved. The dependence of DIR algorithm on image deformation extent and different contrast levels is well characterized through the combined use of multiple similarity indices.


Asunto(s)
Algoritmos , Procesamiento de Imagen Asistido por Computador/métodos , Fantasmas de Imagen , Interpretación de Imagen Radiográfica Asistida por Computador/métodos , Tomografía Computarizada por Rayos X/métodos , Humanos , Dosificación Radioterapéutica
9.
Strahlenther Onkol ; 194(3): 243-254, 2018 03.
Artículo en Inglés | MEDLINE | ID: mdl-29255923

RESUMEN

PURPOSE: This study aimed to test the sensitivity of a transmission detector for online dose monitoring of intensity-modulated radiation therapy (IMRT) for detecting small delivery errors. Furthermore, the correlation of changes in detector output induced by small delivery errors with other metrics commonly employed to quantify the deviations between calculated and delivered dose distributions was investigated. METHODS: Transmission detector measurements were performed at three institutions. Seven types of errors were induced in nine clinical step-and-shoot (S&S) IMRT plans by modifying the number of monitor units (MU) and introducing small deviations in leaf positions. Signal reproducibility was investigated for short- and long-term stability. Calculated dose distributions were compared in terms of γ passing rates and dose-volume histogram (DVH) metrics (e.g., Dmean, Dx%, Vx%). The correlation between detector signal variations, γ passing rates, and DVH parameters was investigated. RESULTS: Both short- and long-term reproducibility was within 1%. Dose variations down to 1 MU (∆signal 1.1 ± 0.4%) as well as changes in field size and positions down to 1 mm (∆signal 2.6 ± 1.0%) were detected, thus indicating high error-detection sensitivity. A moderate correlation of detector signal was observed with γ passing rates (R2 = 0.57-0.70), while a good correlation was observed with DVH metrics (R2 = 0.75-0.98). CONCLUSION: The detector is capable of detecting small delivery errors in MU and leaf positions, and is thus a highly sensitive dose monitoring device for S&S IMRT for clinical practice. The results of this study indicate a good correlation of detector signal with DVH metrics; therefore, clinical action levels can be defined based on the presented data.


Asunto(s)
Sistemas de Computación , Monitoreo de Radiación/instrumentación , Dosificación Radioterapéutica , Planificación de la Radioterapia Asistida por Computador/instrumentación , Errores de Configuración en Radioterapia/prevención & control , Radioterapia de Intensidad Modulada/instrumentación , Humanos , Órganos en Riesgo , Garantía de la Calidad de Atención de Salud , Monitoreo de Radiación/métodos , Planificación de la Radioterapia Asistida por Computador/métodos , Radioterapia de Intensidad Modulada/métodos , Sensibilidad y Especificidad , Estadística como Asunto
10.
Radiol Med ; 122(5): 392-397, 2017 May.
Artículo en Inglés | MEDLINE | ID: mdl-28197874

RESUMEN

PURPOSE: Radiosurgery (RS) is a well-established treatment in selected patients with brain metastasis. The aim of this study is to compare the differences between CyberKnife (CK) and TomoTherapy (HT) treatment plans of RS of single brain metastasis (BM) to define when HT should be used in cases beyond Cyberknife-when both systems are readily available for the radiation oncologist. METHODS AND MATERIALS: Nineteen patients with single brain metastasis treated with CK were re-planned for radiosurgery using TomoTherapy Hi-ART system. Two planning approaches have been used for TomoTherapy plans: the classical one (HT) and the improved conformity (icHT) that produces dose distributions more similar to those of RS plans. PTV coverage, Conformity Index (CI), Paddick Conformity Index (nCI), Homogeneity Index (HI), Gradient Index (GI), and beam on time of CK, HT, and icHT plans were evaluated and compared. RESULTS: A good coverage was found for CK, HT, and icHT plans. A difference between mean HI of CK and icHT plans was observed (p = 0.007). Better dose gradients compared to both icHT and HT modalities were observed in CK plans. icHT modality showed improved mean CI respect to HT modality, similar to that obtained in CK plans. CONCLUSIONS: CK plans show higher conformity and lower GI than icHT and HT plans. TomoTherapy demonstrates the advantage of being a device capable to reach different clinical objectives depending on the different planning modality employed. CyberKnife and TomoTherapy are both optimal RS devices, the choice to use one over another has to be clinically guided.


Asunto(s)
Neoplasias Encefálicas/secundario , Neoplasias Encefálicas/terapia , Metastasectomía/métodos , Planificación de Atención al Paciente , Radiocirugia , Radioterapia de Intensidad Modulada , Humanos , Radiometría
11.
Breast Cancer Res Treat ; 153(3): 539-47, 2015 Oct.
Artículo en Inglés | MEDLINE | ID: mdl-26350524

RESUMEN

The purpose of this study was to report the efficacy and the safety profile on the subset of selected early breast cancer (BC) patients aged 70 years or older from a single-center phase 3 trial comparing whole breast irradiation (WBI) to accelerated partial breast irradiation (APBI) using intensity-modulated radiation therapy technique. Between 2005 and 2013, 520 patients aged more than 40 years old were enrolled and randomly assigned to receive either WBI or APBI in a 1:1 ratio. Eligible patients were women with early BC (maximum diameter 2.5 cm) suitable for breast conserving surgery. This study is registered with ClinicalTrials.gov, NCT02104895. A total of 117 patients aged 70 years or more were analyzed (58 in the WBI arm, 59 in the APBI arm). At a median follow-up of 5-years (range 3.4-7.0), the ipsilateral breast tumor recurrence (IBTR) rate was 1.9 % in both groups. No significant difference between the two groups was identified (log-rank test p = 0.96). The 5-year disease-free survival (DFS) rates in the WBI group and APBI group were 6.1 and 1.9 %, respectively (p = 0.33). The APBI group presented significantly better results in terms of acute skin toxicity, considering both any grade (p = 0.0001) and grade 2 or higher (p = 0.0001). Our subgroup analyses showed a very low rate and no significant difference in terms of IBTR, using both WBI and APBI. A significant impact on patients compliance in terms of acute and early late toxicity was shown, which could translate in a consistent improvement of overall quality of life.


Asunto(s)
Neoplasias de la Mama/radioterapia , Radioterapia de Intensidad Modulada/métodos , Factores de Edad , Anciano , Anciano de 80 o más Años , Biomarcadores de Tumor , Neoplasias de la Mama/diagnóstico , Neoplasias de la Mama/mortalidad , Femenino , Estudios de Seguimiento , Humanos , Estimación de Kaplan-Meier , Clasificación del Tumor , Metástasis de la Neoplasia , Estadificación de Neoplasias , Radioterapia Conformacional/métodos , Radioterapia de Intensidad Modulada/efectos adversos , Resultado del Tratamiento
12.
Strahlenther Onkol ; 191(9): 726-33, 2015 Sep.
Artículo en Inglés | MEDLINE | ID: mdl-26087908

RESUMEN

AIM: The aim of this study was to compare surface imaging, portal imaging, and skin marker set-up in radiotherapy of thoracic and pelvic regions, using cone beam computed tomography (CBCT) data as the gold standard. PATIENTS AND METHODS: Twenty patients were included in this study. CBCT, surface acquisition (SA), and two orthogonal portal images (PI) were acquired during the first four treatment sessions. Patient set-up corrections, obtained by registering the planning CT with CBCT, were used as the gold standard. Registration results of the PI and SA were evaluated and compared with those obtained with CBCT. The advantage derived from using SA or PI verification systems over a skin marker set-up was also quantified. RESULTS: A statistically significant difference between PI and SA (in favour of PI) was observed in seven patients undergoing treatment of the pelvic region and in two patients undergoing treatment of the thoracic region. The use of SA or PI, compared with a skin marker set-up, improved patient positioning in 50% and 57% of the thoracic fractions, respectively. For pelvic fractions, the use of PI was beneficial in 73% of the cases, while the use of SA was beneficial in only 45%. Patient positioning worsened with SA, particularly along longitudinal and vertical directions. CONCLUSION: PI yielded more accurate registration results than SA for both pelvic and thoracic fractions. Compared with the skin marker set-up, PI performances were superior to SA for pelvic fractions while comparable results were obtained for thoracic fractions.


Asunto(s)
Marcadores Fiduciales , Posicionamiento del Paciente/métodos , Neoplasias Pélvicas/radioterapia , Radioterapia Guiada por Imagen/métodos , Neoplasias Torácicas/radioterapia , Imagen de Cuerpo Entero/métodos , Tomografía Computarizada de Haz Cónico/instrumentación , Tomografía Computarizada de Haz Cónico/métodos , Femenino , Humanos , Masculino , Neoplasias Pélvicas/diagnóstico por imagen , Neoplasias Pélvicas/patología , Errores de Configuración en Radioterapia/prevención & control , Radioterapia Guiada por Imagen/instrumentación , Reproducibilidad de los Resultados , Sensibilidad y Especificidad , Piel/patología , Neoplasias Torácicas/diagnóstico por imagen , Neoplasias Torácicas/patología , Imagen de Cuerpo Entero/instrumentación
13.
Radiol Med ; 120(11): 1078-82, 2015 Nov.
Artículo en Inglés | MEDLINE | ID: mdl-25907992

RESUMEN

PURPOSE: The aim of our study was to evaluate the usefulness of the four-dimensional computed tomography (4DCT) in accelerated partial breast irradiation (aPBI) planning. MATERIALS AND METHODS: At our Institute, we have been treating the index quadrant with external intensity-modulated radiation therapy in a phase III trial. For this study, we selected a sample of 10 patients with right- or left-sided breast cancer and surgical clips at the excision site. Contouring of the target was performed both using three-dimensional computed tomography (3DCT) and 4DCT imaging. On both 3DCT and 4DCT, we recorded the clinical target volume (CTV) and the planning target volume (PTV) and the coordinates of the PTV centroid. We calculated the treatment plans, according to our protocol, using the contours drawn on the 3DCT and 4DCT and evaluated target coverage and sparing of organs at risk (OAR). RESULTS: Median age of the patients was 63.5 years (range 52-75). The comparison between the 3DCT and 4DCT PTV volumes was not statistically significant (p = 0.79). Concerning centroid coordinates, the average absolute differences were 0.1 mm in the latero-lateral, 0.7 mm in the antero-posterior and 0.3 mm in the supero-inferior direction. No statistically significant differences were observed both in PTV coverage and OAR sparing; the 4D PTV contour is adequately covered when the plan based on the 3D contours is used. Target coverage was reduced on average by 1 % and no statistically significant difference was observed (p = 0.93). CONCLUSIONS: In our experience, no significant differences between PTV volumes, PTV coverage, OAR sparing and centroid position are evidenced when comparing 3DCT and 4DCT plans. Conventional 3DCT-based planning is adequate for aPBI.


Asunto(s)
Neoplasias de la Mama/diagnóstico por imagen , Neoplasias de la Mama/radioterapia , Tomografía Computarizada Cuatridimensional , Planificación de la Radioterapia Asistida por Computador/métodos , Anciano , Neoplasias de la Mama/patología , Femenino , Humanos , Persona de Mediana Edad , Estadificación de Neoplasias
14.
J Appl Clin Med Phys ; 15(1): 4100, 2014 Jan 06.
Artículo en Inglés | MEDLINE | ID: mdl-24423831

RESUMEN

Linac-based stereotactic radiosurgery (SRS) has been widely used for treating small intracranial lesions. This technique allows conforming the dose distribution to the planning target volume (PTV), providing a steep dose gradient with the surrounding normal tissues. This is realized through dedicated collimation systems. The present study aims to compare SRS plans with two collimating systems: the beam modulator (BM) of the Elekta Synergy linac and the DirexGroup micromultileaf collimator (µMLC). Seventeen patients (25 PTVs) were planned both with BM and µMLC (mounted on an Elekta Precise linac) using the Odyssey (PerMedics) treatment planning system (TPS). Plans were compared in terms of dose-volume histograms (DVH), minimum dose to the PTV, conformity index (CI), and homogeneity index (HI), as defined by the TPS, and doses to relevant organs at risk (OAR). The mean difference between the µMLC and the BM plans in minimum PTV dose was 5.7% ± 4.2% in favor of the µMLC plans. No statistically significant difference was found between the distributions of the CI values for the two planning modalities (p = 0.54), while the difference between the distributions of the HI values was statistically significant (p = 0.018). For both BM and µMLC plans, no differences were observed in CI and HI, depending on lesion size and shape. The PTV homogeneity achieved by BM plans was 15.1% ± 6.8% compared to 10.4% ± 6.6% with µMLC. Higher maximum and mean doses to OAR were observed in the BM plans; however, for both plans, dose constraints were respected. The comparison between the two collimating systems showed no substantial differences in terms of PTV coverage or OAR sparing. The improvements obtained by using µMLC are relatively small, and both systems turned out to be adequate for SRS treatments.


Asunto(s)
Neoplasias Encefálicas/cirugía , Aceleradores de Partículas , Radiocirugia/instrumentación , Planificación de la Radioterapia Asistida por Computador , Técnicas Estereotáxicas/instrumentación , Humanos , Órganos en Riesgo , Radiocirugia/métodos , Dosificación Radioterapéutica
15.
Artículo en Inglés | MEDLINE | ID: mdl-38882236

RESUMEN

Introduction: The radiotherapy workflow involves the collaboration of multiple professionals and the execution of several steps to results in an effective treatment. In this study, we described the clinical implementation of an electronic checklist, developed to standardize the process of the chart review prior to the first treatment fraction by the radiation therapists (RTTs). Materials and Methods: A customized electronic checklist was developed based on the recommendations of American Association of Physicists in Medicine (AAPM) Task Groups 275 and 315 and integrated into the Record and Verify System (RVS). The checklist consisted of 16 items requiring binary (yes/no) responses, with mandatory completion and review by RTTs prior to treatment. The utility of the checklist and its impact on workflow were assessed by analysing checklist reports, and by soliciting feedback to RTTs through an anonymized survey. Results: During the first trial phase, from June to November 2023, 285 checklists were completed with a 98% compilation rate and 94.4% review rate. Forty errors were detected, mainly due to missing signed treatment plans and absence of Beam's Eye View documentation. Ninety percent of detected errors were fixed before the treatment start. In 4 cases, the problem could not be fixed before the first fraction, resulting in a suboptimal first treatment. The feedback survey showed that RTTs described the checklist as useful, with minimal impact on workload, and supported its implementation. Discussion: The introduction of a customized electronic checklist improved the detection and correction of errors, thereby enhancing patient safety. The positive response from RTTs and the minimal impact on workflow underscore the value of the checklist as standard practice in radiotherapy departments.

16.
Med Phys ; 51(6): 4489-4503, 2024 Jun.
Artículo en Inglés | MEDLINE | ID: mdl-38432192

RESUMEN

BACKGROUND: The increasing use of complex and high dose-rate treatments in radiation therapy necessitates advanced detectors to provide accurate dosimetry. Rather than relying on pre-treatment quality assurance (QA) measurements alone, many countries are now mandating the use of in vivo dosimetry, whereby a dosimeter is placed on the surface of the patient during treatment. Ideally, in vivo detectors should be flexible to conform to a patient's irregular surfaces. PURPOSE: This study aims to characterize a novel hydrogenated amorphous silicon (a-Si:H) radiation detector for the dosimetry of therapeutic x-ray beams. The detectors are flexible as they are fabricated directly on a flexible polyimide (Kapton) substrate. METHODS: The potential of this technology for application as a real-time flexible detector is investigated through a combined dosimetric and flexibility study. Measurements of fundamental dosimetric quantities were obtained including output factor (OF), dose rate dependence (DPP), energy dependence, percentage depth dose (PDD), and angular dependence. The response of the a-Si:H detectors investigated in this study are benchmarked directly against commercially available ionization chambers and solid-state diodes currently employed for QA practices. RESULTS: The a-Si:H detectors exhibit remarkable dose linearities in the direct detection of kV and MV therapeutic x-rays, with calibrated sensitivities ranging from (0.580 ± 0.002) pC/cGy to (19.36 ± 0.10) pC/cGy as a function of detector thickness, area, and applied bias. Regarding dosimetry, the a-Si:H detectors accurately obtained OF measurements that parallel commercially available detector solutions. The PDD response closely matched the expected profile as predicted via Geant4 simulations, a PTW Farmer ionization chamber and a PTW ROOS chamber. The most significant variation in the PDD performance was 5.67%, observed at a depth of 3 mm for detectors operated unbiased. With an external bias, the discrepancy in PDD response from reference data was confined to ± 2.92% for all depths (surface to 250 mm) in water-equivalent plastic. Very little angular dependence is displayed between irradiations at angles of 0° and 180°, with the most significant variation being a 7.71% decrease in collected charge at a 110° relative angle of incidence. Energy dependence and dose per pulse dependence are also reported, with results in agreement with the literature. Most notably, the flexibility of a-Si:H detectors was quantified for sample bending up to a radius of curvature of 7.98 mm, where the recorded photosensitivity degraded by (-4.9 ± 0.6)% of the initial device response when flat. It is essential to mention that this small bending radius is unlikely during in vivo patient dosimetry. In a more realistic scenario, with a bending radius of 15-20 mm, the variation in detector response remained within ± 4%. After substantial bending, the detector's photosensitivity when returned to a flat condition was (99.1 ± 0.5)% of the original response. CONCLUSIONS: This work successfully characterizes a flexible detector based on thin-film a-Si:H deposited on a Kapton substrate for applications in therapeutic x-ray dosimetry. The detectors exhibit dosimetric performances that parallel commercially available dosimeters, while also demonstrating excellent flexibility results.


Asunto(s)
Radiometría , Silicio , Radiometría/instrumentación , Hidrógeno , Dosimetría in Vivo , Terapia por Rayos X/instrumentación , Humanos
18.
Pract Radiat Oncol ; 13(1): e28-e34, 2023.
Artículo en Inglés | MEDLINE | ID: mdl-35659597

RESUMEN

Several phase 3 trials have demonstrated partial breast irradiation noninferiority compared with whole breast irradiation in terms of local control and similar or reduced toxicity. During recent years, especially owing to the COVID-19 pandemic, a growing interest in 5-fraction regimens emerged. The APBI-IMRT-Florence trial (NCT02104895) schedule (30 Gy in 5 fractions) might represent an appealing treatment option, being both a safe and effective partial breast irradiation schedule, with long-term reported results. The aim of this report is to support planners interested in implementing this technique and to warrant equal access to postoperative radiation treatment for most early breast cancer patient candidates. We report the current delivery technique optimized from the original protocol and the updated dose constraints for plan optimization. We also report a statistical analysis of dosimetric parameters on 50 patients treated in consecutive fractions. Treatment-related toxic effects were assessed using the acute radiation morbidity scoring criteria and late radiation morbidity scoring scheme from the Radiation Therapy Oncology Group and the European Organisation for Research and Treatment of Cancer. The mean volume of ipsilateral breast was 731 cm3 (standard deviation ± 450; range, 151-2205) and the mean planning target volume (PTV) was 139 cm3 (standard deviation ± 48; range, 55-259). There was good correlation between ipsilateral breast V15Gy and the ratio between the PTV and ipsilateral breast volume (R2 = .911). At a median follow-up of 4.5 years, 32% of patients (n = 16) developed any grade 1 acute toxic effect. No grade >1 toxic effect was observed. Sixteen percent of patients (n = 8) developed any grade 1 late toxic effect. No grade >1 toxic effect was observed. Physician-assessed cosmesis was reported as excellent (84%), good (14%), and fair (2%). The schedule of 30 Gy in 5 consecutive fractions might represent a safe, easy-to-deliver, and cost-effective option for appropriately selected patients affected by early breast cancer.


Asunto(s)
Neoplasias de la Mama , COVID-19 , Radioterapia de Intensidad Modulada , Humanos , Femenino , Radioterapia de Intensidad Modulada/efectos adversos , Radioterapia de Intensidad Modulada/métodos , Pandemias , COVID-19/etiología , Neoplasias de la Mama/cirugía , Mama/efectos de la radiación
19.
Radiat Oncol ; 18(1): 176, 2023 Oct 30.
Artículo en Inglés | MEDLINE | ID: mdl-37904150

RESUMEN

BACKGROUND: This study aimed to evaluate an a-priori multicriteria plan optimization algorithm (mCycle) for locally advanced breast cancer radiation therapy (RT) by comparing automatically generated VMAT (Volumetric Modulated Arc Therapy) plans (AP-VMAT) with manual clinical Helical Tomotherapy (HT) plans. METHODS: The study included 25 patients who received postoperative RT using HT. The patient cohort had diverse target selections, including both left and right breast/chest wall (CW) and III-IV node, with or without internal mammary node (IMN) and Simultaneous Integrated Boost (SIB). The Planning Target Volume (PTV) was obtained by applying a 5 mm isotropic expansion to the CTV (Clinical Target Volume), with a 5 mm clip from the skin. Comparisons of dosimetric parameters and delivery/planning times were conducted. Dosimetric verification of the AP-VMAT plans was performed. RESULTS: The study showed statistically significant improvements in AP-VMAT plans compared to HT for OARs (Organs At Risk) mean dose, except for the heart and ipsilateral lung. No significant differences in V95% were observed for PTV breast/CW and PTV III-IV, while increased coverage (higher V95%) was seen for PTV IMN in AP-VMAT plans. HT plans exhibited smaller values of PTV V105% for breast/CW and III-IV, with no differences in PTV IMN and boost. HT had an average (± standard deviation) delivery time of (17 ± 8) minutes, while AP-VMAT took (3 ± 1) minutes. The average γ passing rate for AP-VMAT plans was 97%±1%. Planning times reduced from an average of 6 h for HT to about 2 min for AP-VMAT. CONCLUSIONS: Comparing AP-VMAT plans with clinical HT plans showed similar or improved quality. The implementation of mCycle demonstrated successful automation of the planning process for VMAT treatment of locally advanced breast cancer, significantly reducing workload.


Asunto(s)
Neoplasias de la Mama , Radioterapia de Intensidad Modulada , Humanos , Femenino , Radioterapia de Intensidad Modulada/métodos , Neoplasias de la Mama/radioterapia , Dosificación Radioterapéutica , Planificación de la Radioterapia Asistida por Computador/métodos , Radiometría/métodos , Órganos en Riesgo
20.
Phys Med Biol ; 68(13)2023 06 28.
Artículo en Inglés | MEDLINE | ID: mdl-37267990

RESUMEN

Objective. Microbeam radiation therapy (MRT) is an alternative emerging radiotherapy treatment modality which has demonstrated effective radioresistant tumour control while sparing surrounding healthy tissue in preclinical trials. This apparent selectivity is achieved through MRT combining ultra-high dose rates with micron-scale spatial fractionation of the delivered x-ray treatment field. Quality assurance dosimetry for MRT must therefore overcome a significant challenge, as detectors require both a high dynamic range and a high spatial resolution to perform accurately.Approach. In this work, a series of radiation hard a-Si:H diodes, with different thicknesses and carrier selective contact configurations, have been characterised for x-ray dosimetry and real-time beam monitoring applications in extremely high flux beamlines utilised for MRT at the Australian Synchrotron.Results. These devices displayed superior radiation hardness under constant high dose-rate irradiations on the order of 6000 Gy s-1, with a variation in response of 10% over a delivered dose range of approximately 600 kGy. Dose linearity of each detector to x-rays with a peak energy of 117 keV is reported, with sensitivities ranging from (2.74 ± 0.02) nC/Gy to (4.96 ± 0.02) nC/Gy. For detectors with 0.8µm thick active a-Si:H layer, their operation in an edge-on orientation allows for the reconstruction of micron-size beam profiles (microbeams). The microbeams, with a nominal full-width-half-max of 50µm and a peak-to-peak separation of 400µm, were reconstructed with extreme accuracy. The full-width-half-max was observed as 55 ± 1µm. Evaluation of the peak-to-valley dose ratio and dose-rate dependence of the devices, as well as an x-ray induced charge (XBIC) map of a single pixel is also reported.Significance. These devices based on novel a-Si:H technology possess a unique combination of accurate dosimetric performance and radiation resistance, making them an ideal candidate for x-ray dosimetry in high dose-rate environments such as FLASH and MRT.


Asunto(s)
Silicio , Sincrotrones , Rayos X , Australia , Radiometría/métodos
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA