Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 95
Filtrar
Más filtros

Bases de datos
País/Región como asunto
Tipo del documento
País de afiliación
Intervalo de año de publicación
1.
J Clin Ultrasound ; 2024 Jun 27.
Artículo en Inglés | MEDLINE | ID: mdl-38934699

RESUMEN

BACKGROUND: The application value of myocardial work (MW) in evaluating myocardial function and predicting major adverse cardiovascular events (MACE) in maintenance hemodialysis (MHD) patients has not been fully explored. PURPOSE: Comparing noninvasive MW parameters between MHD patients and healthy controls, and further determining its value in predicting MACE in MHD patients. METHODS: A prospective single-institution study included 92 MHD patients without prior cardiovascular disease and 40 age- and sex-matched healthy controls. Conventional echocardiographic data, global longitudinal strain (GLS), and MW parameters (global work index [GWI], global constructive work [GCW], global work efficiency [GWE], global wasted work [GWW]) were derived and compared between MHD and the control. Logistic regression was used to determine the predictive value of these parameters for MACE. The receiver operating characteristic curve was utilized to compare the predictive differences of MACE between GWE and GLS. RESULTS: Compared with healthy individuals, MHD patients had significantly reduced GWE, GLS and elevated LVMI, GWW (all p < 0.001), while there was no significant difference in left ventricular ejection fraction. Twenty eight (30%) MHD patients experienced MACE. Two nested models adding GWE and GLS, respectively, showed that age (p < 0.005), GWE (p = 0.034), and GLS (p = 0.014) were independent predictors of MACE. The AUC derived from GWE for predicting MACE was significantly higher than that derived from GLS (0.836 vs. 0.743, p = 0.039). CONCLUSIONS: Myocardial work is a novel tool for assessing left ventricular myocardial performance in MHD patients. GWE is an independent predictor of MACE.

2.
Int Wound J ; 21(2): e14594, 2024 Feb.
Artículo en Inglés | MEDLINE | ID: mdl-38379217

RESUMEN

To evaluate the efficacy of cognitive behavioural therapy (CBT) as a psychological intervention for elderly patients with extensive burns, focusing on its impact on emotional well-being, self-efficacy and quality of life. A prospective, randomized study involving 200 elderly burn patients was conducted from November 2021 to January 2023. The patients were randomly assigned to receive either standard care (control group) or burn care based on cognitive behavioural therapy (CBT-B) (study group), with 100 patients in each group. Outcome measures included the Visual Analog Scale (VAS) for pain assessment, 36-item Short Form Survey (SF-36) for quality of life, General Self-Efficacy Scale (GSES) and Rosenberg Self-Esteem Scale (RSES). The study revealed that CBT-based intervention significantly reduced anxiety and depression scores compared with standard care (p < 0.05). Additionally, patients in the CBT group exhibited improved self-efficacy, self-esteem and quality of life (p < 0.05). CBT proves to be a valuable intervention for elderly burn patients, effectively addressing emotional distress and enhancing their psychological well-being. By modifying negative cognitive patterns, providing coping mechanisms and fostering problem-solving skills, CBT-based care contributes to a more positive recovery experience and improved quality of life.


Asunto(s)
Terapia Cognitivo-Conductual , Calidad de Vida , Humanos , Anciano , Estudios Prospectivos , Intervención Psicosocial , Ansiedad/terapia
3.
Catheter Cardiovasc Interv ; 102(2): 301-309, 2023 08.
Artículo en Inglés | MEDLINE | ID: mdl-37471710

RESUMEN

BACKGROUND: The ValveClasp system is a novel transcatheter edge-to-edge repair (TEER) device with an arm-width-expandable clip that allows treatment of patients with only one clip more frequently. OBJECTIVES: This study aimed to evaluate the feasibility and safety of a novel TEER device in porcine models and patients. METHODS: Fourteen young adult pigs were enrolled. A clip with an expanded arm was implanted under epicardial echocardiography and fluoroscopy guidance. Five patients with at least moderate-to-severe mitral regurgitation underwent TEER using the ValveClasp system to test the safety and effectiveness of the device. RESULTS: The device success rate was 100% (14/14) in the animal experiments, and all clips were deployed at the A2P2 segments, forming a double-orifice mitral valve. Gross observations on day 180 showed a wide and continuous tissue bridge between the leaflets. The acute procedural success rate was 100% (5/5). Only one clip was required in all patients, and all achieved effective postoperative endpoints (grade ≤2+). During 30-day follow-up, no adverse events occurred. All patients' vena Contracta width (from 8.04 0.71 mm to 3.84 ± 1.18 mm, p = 0.012), mitral regurgitation area (from 12.75 ± 3.13 cm2 to 3.50 ± 1.66 cm2 , p = 0.008), and left ventricular end diastolic diameter (from 52.00 ± 2.92 mm to 46.00 ± 3.08 mm, p = 0.040) were considerably decreased, without obvious mitral stenosis. CONCLUSIONS: The novel arm-width-expandable ValveClasp device is safe for TEER for treating severe mitral regurgitation.


Asunto(s)
Implantación de Prótesis de Válvulas Cardíacas , Insuficiencia de la Válvula Mitral , Animales , Humanos , Cateterismo Cardíaco/efectos adversos , Ecocardiografía , Implantación de Prótesis de Válvulas Cardíacas/efectos adversos , Válvula Mitral/diagnóstico por imagen , Válvula Mitral/cirugía , Insuficiencia de la Válvula Mitral/diagnóstico por imagen , Insuficiencia de la Válvula Mitral/cirugía , Insuficiencia de la Válvula Mitral/etiología , Porcinos , Resultado del Tratamiento
4.
Eur Radiol ; 33(10): 7238-7249, 2023 Oct.
Artículo en Inglés | MEDLINE | ID: mdl-37145148

RESUMEN

OBJECTIVES: We applied a fully automated pixel-wise post-processing framework to evaluate fully quantitative cardiovascular magnetic resonance myocardial perfusion imaging (CMR-MPI). In addition, we aimed to evaluate the additive value of coronary magnetic resonance angiography (CMRA) to the diagnostic performance of fully automated pixel-wise quantitative CMR-MPI for detecting hemodynamically significant coronary artery disease (CAD). METHODS: A total of 109 patients with suspected CAD were prospectively enrolled and underwent stress and rest CMR-MPI, CMRA, invasive coronary angiography (ICA), and fractional flow reserve (FFR). CMRA was acquired between stress and rest CMR-MPI acquisition, without any additional contrast agent. Finally, CMR-MPI quantification was analyzed by a fully automated pixel-wise post-processing framework. RESULTS: Of the 109 patients, 42 patients had hemodynamically significant CAD (FFR ≤ 0.80 or luminal stenosis ≥ 90% on ICA) and 67 patients had hemodynamically non-significant CAD (FFR ˃ 0.80 or luminal stenosis < 30% on ICA) were enrolled. On the per-territory analysis, patients with hemodynamically significant CAD had higher myocardial blood flow (MBF) at rest, lower MBF under stress, and lower myocardial perfusion reserve (MPR) than patients with hemodynamically non-significant CAD (p < 0.001). The area under the receiver operating characteristic curve of MPR (0.93) was significantly larger than those of stress and rest MBF, visual assessment of CMR-MPI, and CMRA (p < 0.05), but similar to that of the integration of CMR-MPI with CMRA (0.90). CONCLUSIONS: Fully automated pixel-wise quantitative CMR-MPI can accurately detect hemodynamically significant CAD, but the integration of CMRA obtained between stress and rest CMR-MPI acquisition did not provide significantly additive value. KEY POINTS: • Full quantification of stress and rest cardiovascular magnetic resonance myocardial perfusion imaging can be postprocessed fully automatically, generating pixel-wise myocardial blood flow (MBF) and myocardial perfusion reserve (MPR) maps. • Fully quantitative MPR provided higher diagnostic performance for detecting hemodynamically significant coronary artery disease, compared with stress and rest MBF, qualitative assessment, and coronary magnetic resonance angiography (CMRA). • The integration of CMRA and MPR did not significantly improve the diagnostic performance of MPR alone.


Asunto(s)
Enfermedad de la Arteria Coronaria , Estenosis Coronaria , Reserva del Flujo Fraccional Miocárdico , Imagen de Perfusión Miocárdica , Humanos , Enfermedad de la Arteria Coronaria/diagnóstico , Angiografía Coronaria/métodos , Reserva del Flujo Fraccional Miocárdico/fisiología , Constricción Patológica , Valor Predictivo de las Pruebas , Perfusión , Imagen de Perfusión Miocárdica/métodos
5.
Echocardiography ; 40(9): 932-941, 2023 09.
Artículo en Inglés | MEDLINE | ID: mdl-37498192

RESUMEN

BACKGROUND: The purpose of the study was to determine the association between vena contracta area (VCA) and secondary leaflet tethering among mitral valve prolapse (MVP) patients, and thus to further identify and characterize an MVP with pathological leaflet tethering (MVPt+) phenotype. METHODS: We prospectively evaluated 94 consecutive MVP patients with significant mitral regurgitation (MR) and 21 healthy controls. MVPt+ group was defined as tenting volume index (TVi) > .7 mL/m2 . The three-dimensional (3D) geometry of mitral valve apparatus and VCA was measured with dedicated quantification software. RESULTS: Of the 94 patients with MVP and significant MR, 31 patients showed a TVi > .7 mL/m2 and entered the MVP with leaflet tethering (MVPt+) group. In stepwise multivariate analysis, only prolapse volume index and TVi were independently associated with 3D VCA. 3D VCA, annular area index, and plasma levels of NT-proBNP were independently correlated with the severity of leaflet tethering. ROC curve revealed that a 3D VCA ≥ .55 cm2 is the optimal cutoff point to predict MVPt+ phenotype. CONCLUSIONS: Secondary leaflet tethering is a significant mechanism behind severe degenerative MR, resulting in an MVPt+ phenotype featuring more advanced morphological and hemodynamical characteristics.


Asunto(s)
Ecocardiografía Tridimensional , Insuficiencia de la Válvula Mitral , Prolapso de la Válvula Mitral , Humanos , Insuficiencia de la Válvula Mitral/complicaciones , Insuficiencia de la Válvula Mitral/diagnóstico por imagen , Ecocardiografía Transesofágica/métodos , Ecocardiografía Tridimensional/métodos , Prolapso de la Válvula Mitral/complicaciones , Válvula Mitral/diagnóstico por imagen
6.
Surg Today ; 53(1): 90-97, 2023 Jan.
Artículo en Inglés | MEDLINE | ID: mdl-36088621

RESUMEN

PURPOSE: The ValveClamp system is a novel edge-to-edge mitral valve repair system designed for the ease of operation. We report the outcomes of our initial experience of treating functional mitral regurgitation (MR) with the ValveClamp system. METHODS: The subjects of this study were patients with symptomatic functional MR despite standard medical therapy, who were treated with transapical ValveClamp implantation. The patients were divided into an atrial functional mitral regurgitation (AFMR) group and a ventricular functional mitral regurgitation (VFMR) group. Clinical and echocardiographic outcomes were evaluated at baseline and then at the 3-month follow up. RESULTS: Twelve patients, with a median age of 71 years (range 65-78 years), were assigned to the AFMR group (n = 5) or the VFMR group (n = 7). The device implantation rate was 100%, and 10 (83.3%) patients required implantation of only one clamp. The catheter time was less than 10 min in half of the patients, the fastest time being 5 min. There were no procedure-related complications. At the 3-month follow up, all patients were free from all-cause mortality, surgery, and rehospitalization. MR improved to ≤ 2 + in all 12 patients with MR grade 3 + or 4 + at baseline, (100%) and to ≤ 1 + in 9 of these patients (75%), with a low-pressure gradient. The left atrial diameter and the left ventricular end diastolic diameter decreased significantly in both the AFMR and VFMR groups. The left ventricular eject fraction at the 3-month follow up showed a rising trend in both the AFMR and VFMR groups, whereas PASP decreased remarkably. All 12 patients with baseline NYHA functional class III/IV (100%) showed improvement of at least 1 class, and 2 of these patients (16.7%) showed improvement of at least 2 classes. CONCLUSIONS: The ValveClamp system is simple and effective for transapical transcatheter edge to edge repair in patients with functional MR.


Asunto(s)
Fibrilación Atrial , Implantación de Prótesis de Válvulas Cardíacas , Insuficiencia de la Válvula Mitral , Humanos , Anciano , Insuficiencia de la Válvula Mitral/diagnóstico por imagen , Insuficiencia de la Válvula Mitral/cirugía , Insuficiencia de la Válvula Mitral/etiología , Válvula Mitral/diagnóstico por imagen , Válvula Mitral/cirugía , Fibrilación Atrial/cirugía , Resultado del Tratamiento , Catéteres/efectos adversos
7.
Eur Radiol ; 32(11): 7657-7667, 2022 Nov.
Artículo en Inglés | MEDLINE | ID: mdl-35567603

RESUMEN

OBJECTIVES: Immune checkpoint inhibitor (ICI)-associated myocarditis is a potentially fatal complication. Sparse published researches evaluated the prognostic value of cardiovascular magnetic resonance feature tracking (CMR-FT) for ICI-associated myocarditis. METHODS: In the single-center retrospective study, 52 patients with ICI-associated myocarditis and CMR were included from August 2018 to July 2021. The ICI-associated myocarditis was diagnosed by using the clinical criteria of the European Society of Cardiology guidelines. Major adverse cardiovascular events (MACE) were comprised of cardiovascular death, cardiogenic shock, cardiac arrest, and complete heart block. RESULTS: During a median follow-up of 171 days, 14 (27%) patients developed MACE. For patients with MACE, the global circumferential strain (GCS), global radial strain (GRS), global longitudinal strain (GLS), and left ventricular ejection fraction (LVEF) were significantly worse and native T1 values and late gadolinium enhancement (LGE) extent were significantly increased, compared with patients without MACE (p < 0.05). The GLS remained the independent factor associated with a higher risk of MACE (hazard ratio (HR): 2.115; 95% confidence interval (CI): 1.379-3.246; p = 0.001) when adjusting for LVEF, LGE extent, age, sex, body mass index, steroid treatment, and prior cardiotoxic chemotherapy or radiation. After adjustment for LVEF, the GLS remained the independent risk factor associated with a higher rate of MACE among patients with a preserved LVEF (HR: 1.358; 95% CI: 1.007-1.830; p = 0.045). CONCLUSIONS: GLS could provide independent prognostic value over GCS, GRS, traditional CMR features, and clinical features in patients with ICI-associated myocarditis. KEY POINTS: • The global circumferential strain (GCS), global radial strain (GRS), and global longitudinal strain (GLS) by cardiovascular magnetic resonance feature tracking were significantly impaired in patients with an immune checkpoint inhibitor (ICI)-associated myocarditis. • GLS was still significantly impaired in patients with preserved left ventricular ejection fraction. • The worse GLS was an independent risk factor over GCS, GRS, traditional CMR features, and clinical features for predicting major adverse cardiovascular events in patients with ICI-associated myocarditis.


Asunto(s)
Miocarditis , Función Ventricular Izquierda , Humanos , Volumen Sistólico , Miocarditis/inducido químicamente , Miocarditis/diagnóstico por imagen , Imagen por Resonancia Cinemagnética , Inhibidores de Puntos de Control Inmunológico/efectos adversos , Pronóstico , Estudios Retrospectivos , Medios de Contraste/efectos adversos , Gadolinio , Valor Predictivo de las Pruebas , Miocardio
8.
Cardiovasc Ultrasound ; 20(1): 14, 2022 May 05.
Artículo en Inglés | MEDLINE | ID: mdl-35509080

RESUMEN

BACKGROUND: PRKAG2 syndrome is a rare disease characterized as left ventricular hypertrophy (LVH), ventricular preexcitation syndrome, and sudden cardiac death. Its natural course, treatment, and prognosis were significantly different from sarcomeric hypertrophic cardiomyopathy (HCM). However, it is often clinically misdiagnosed as sarcomeric HCM. PRKAG2 patients tend to experience delayed treatment. The delay may lead to adverse outcomes. This study aimed to identify the echocardiographic parameters which can differentiate PRKAG2 syndrome from sarcomeric HCM. METHODS: Nine PRKAG2 patients with LVH, 41 HCM patients with sarcomere gene mutations, and 202 healthy volunteers were enrolled. Clinical characteristics, conventional echocardiography, and three-dimensional images were recorded, and reviewed by an attending cardiologist. We evaluated the parameters of left ventricular strains from three-dimensional speckle tracking echocardiography (3D STE) by TomTec software. Receiver operating characteristic (ROC) curves analysis was used to assess clinical and echocardiographic parameters' differential diagnosis potential. RESULTS: The heart rate (HR) of the PRKAG2 group was significantly lower than both the healthy group (53.11 ± 10.14 vs. 69.22 ± 10.48 bpm, P < 0.001) and the sarcomeric HCM group (53.11 ± 10.14 vs. 67.23 ± 10.32 bpm, P = 0.001). The PRKAG2 group had similar interventricular septal thickness (IVS), posterior wall thickness (PWT), and maximum wall thickness (MWT) to the HCM group (P > 0.05). The absolute value of GLS in the PRKAG2 group was significantly higher than HCM patients (-18.92 ± 4.98 vs. -13.43 ± 4.30%, P = 0.004). SV calculated from EDV and ESV in PRKAG2 syndrome showed a higher value than sarcomeric HCM (61.83 ± 13.52 vs. 44.96 ± 17.53%, P = 0.020). The area under the ROC curve (AUC) for HR + GLS was 0.911 (0.803 -1). For HR + GLS, the sensitivity and specificity of the best cut-off value (0.114) were 69.0% and 100%, respectively. CONCLUSIONS: PRKAG2 patients present deteriorated LV diastolic function and preserved LV systolic function. Bradycardia and preserved GLS are useful to identify PRKAG2 syndrome from sarcomeric HCM, which may be beneficial for clinical decision-making.


Asunto(s)
Cardiomiopatía Hipertrófica , Ecocardiografía Tridimensional , Proteínas Quinasas Activadas por AMP , Cardiomiopatía Hipertrófica/diagnóstico , Cardiomiopatía Hipertrófica/genética , Ecocardiografía , Ventrículos Cardíacos/diagnóstico por imagen , Humanos , Hipertrofia Ventricular Izquierda , Sarcómeros/genética , Función Ventricular Izquierda
9.
Int Heart J ; 63(1): 23-29, 2022.
Artículo en Inglés | MEDLINE | ID: mdl-35095072

RESUMEN

The ValveClamp system is a novel edge-to-edge mitral valve repair system that is designed for ease of operation. We aimed to report the 1-year outcomes of the early feasibility study of this system.Patients with severe degenerative mitral regurgitation (MR) at higher surgical risk and who received transapical ValveClamp implantation were followed for 1 year for clinical and echocardiographic outcomes.Twelve patients (mean age, 76.5 ± 6.3 years; mean Society of Thoracic Surgery score, 6.9 ± 1.9%) were enrolled at three sites in China. At 1 year, no patient died, received reoperation, or had long-term complications. Of the 12 patients with MR of 3+ or 4+ at baseline, 11 patients (91.67%) remained with MR ≤ 2+ at 1 year, and no patient had mitral stenosis. Significant reductions in maximum MR area (from 15.1 ± 6.51 cm2 to 4.45 ± 1.85 cm2, P < 0.001), effective orifice area (from 4.34 ± 0.34 cm2 to 2.38 ± 0.45 cm2, P < 0.001), and vena contracta width (from 8.03 ± 1.11 to 3.38 ± 2.11 mm, P < 0.001) were observed. The left cardiac dimensions were decreased, especially the mitral valve annulus diameter (from 34.79 ± 4.27 mm to 31.42 ± 2.81 mm, P < 0.05). Of the 12 patients with baseline New York Heart Association functional class III/IV, all patients experienced an improvement of at least one class (P < 0.05).Our study provides evidence that transapical ValveClamp implantation in high-risk patients with severe degenerative MR is safe and feasible, with good efficacy in the mid-long term.


Asunto(s)
Implantación de Prótesis de Válvulas Cardíacas/instrumentación , Insuficiencia de la Válvula Mitral/cirugía , Anciano , Anciano de 80 o más Años , Cateterismo Cardíaco , Ecocardiografía , Estudios de Factibilidad , Femenino , Prótesis Valvulares Cardíacas , Humanos , Masculino , Persona de Mediana Edad , Insuficiencia de la Válvula Mitral/diagnóstico por imagen , Insuficiencia de la Válvula Mitral/fisiopatología , Estudios Prospectivos , Factores de Tiempo , Resultado del Tratamiento
10.
Catheter Cardiovasc Interv ; 97(1): 177-185, 2021 01 01.
Artículo en Inglés | MEDLINE | ID: mdl-32497395

RESUMEN

OBJECTIVES: We sought to assess the acute intraprocedural effects of the ValveClamp system in DMR patients on the mitral valve (MV) three-dimensional (3D) geometry and the association of these effects with mitral regurgitation (MR) reduction. BACKGROUND: Few data are available about the specific impact of transcatheter edge-to-edge repair in patients with degenerative mitral regurgitation (DMR). METHODS: Thirty-five symptomatic patients (age 74.26 ± 6.61 years) with Grade 3 to 4+ degenerative MR underwent 3D transoesophageal echocardiography (TEE) during ValveClamp implantation. Volumetric data sets were retrospectively analyzed using mitral valve quantitative 3D modeling software. RESULTS: Mitral valve annular anterior-posterior (AP) diameter decreased from 33.24 ± 4.03 to 31.12 ± 3.66 mm (p < .001), and prolapse height from 4.78 ± 2.19 to 2.32 ± 1.92 mm (p < .001), and total exposed leaflet area from 1,110.29 ± 224.21 mm2 to 1,013.44 ± 228.71 mm (p = .004). Accordingly, we observed a significant reduction of MR severity after ValveClamp implantation. Multivariable analysis revealed postprocedural MR reduction was associated with shortening in anterior-posterior diameter (coefficient 0.427, p = .008) and reduction in prolapse height (coefficient 0.369, p = .021). CONCLUSIONS: ValveClamp implantation exerts an acute effect on the 3D MV geometry. Postprocedural reduction in AP diameter and reduction in prolapse height correlates with MR downgrading in patients with degenerative MR.


Asunto(s)
Ecocardiografía Tridimensional , Insuficiencia de la Válvula Mitral , Anciano , Ecocardiografía Transesofágica , Humanos , Válvula Mitral/diagnóstico por imagen , Válvula Mitral/cirugía , Insuficiencia de la Válvula Mitral/diagnóstico por imagen , Insuficiencia de la Válvula Mitral/cirugía , Estudios Retrospectivos , Resultado del Tratamiento
11.
J Interv Cardiol ; 2021: 6659261, 2021.
Artículo en Inglés | MEDLINE | ID: mdl-33976590

RESUMEN

MitraClip edge-to-edge (E2E) repair system is the only transcatheter device recommended in the current guidelines for treating mitral regurgitation (MR). The percutaneous femoral venous transseptal access of MitraClip requires a complex steerable delivery system and may thus be technically complex to optimally position and deploy the clip onto the mitral valve. A transapical approach for E2E repair has been devised to treat MR for the ease of operation (ValveClamp system, Hanyu Medical Technology, Shanghai). The first-in-human study of ValveClamp has demonstrated its early feasibility and effectiveness for the treatment of patients with degenerative MR. Transesophageal echocardiography (TEE) is the only imaging modality required for intraoperative guidance of ValveClamp implantation. Successful implantation depends on accurate localization and orientation of the clamp and efficient intraoperative communication between the echocardiographer and the intervention team. Thus, the focus of this review is on elaborating how two-dimensional (2D) and three-dimensional (3D) TEE are used in clinical practice to guide ValveClamp implantation and it may facilitate the understanding of simplicity and safety of this novel procedure. We also describe the implementation of several novel advancements in 3D TEE imaging, which improve the confidence of image interpretation for intraoperative guidance and expedite implantation times.


Asunto(s)
Ecocardiografía Transesofágica/métodos , Insuficiencia de la Válvula Mitral/cirugía , Cirugía Asistida por Computador/métodos , Ecocardiografía Tridimensional/métodos , Implantación de Prótesis de Válvulas Cardíacas/instrumentación , Implantación de Prótesis de Válvulas Cardíacas/métodos , Humanos , Válvula Mitral/cirugía , Insuficiencia de la Válvula Mitral/diagnóstico
12.
Cardiovasc Ultrasound ; 18(1): 3, 2020 Jan 21.
Artículo en Inglés | MEDLINE | ID: mdl-31964389

RESUMEN

BACKGROUND: To evaluate the detailed dynamic change of left ventricular diastolic function (LVDF) by echocardiography in aortic stenosis (AS) patients receiving transcatheter aortic valve implantation (TAVI) and compare LVDF classification according to 2009 ASE/EAE and 2016 ASE/EACVI recommendations. METHODS: Thirty-five AS patients receiving TAVI underwent echocardiography the day before operation (PRE), on the third day (3D), in the first-month (1 M) and the six-month (6 M) after TAVI. LVDF was analyzed using 2D and doppler imaging to get parameters including E/A, E/e', isovolumic relaxation time (IVRT), deceleration time, LA area, LA volume index (LAVI) and systolic tricuspid regurgitation velocity (TR). LVDF classification was evaluated four times for each patient according to 2009 and 2016 recommendations respectively and the results were compared. RESULTS: The decrease of IVRT and TR occurred immediately post surgery up to 1-month. Improvement of E/e' occurred late from 3-day to 1-month. LA area and LAVI decreased continuously shortly after operation till 6-month. Forty-four percent (62/140) by 2009 recommendations were reclassified with different grades when using 2016 guidelines. Comparing PRE and 6 M, with 2009 guidelines, 19 patients improved 1 grade, 8 patients improved 2 grades; with 2016 guidelines, 9 patients improved 1 grade, 13 patients improved 2 grades, 1 patient improved 3 grades. CONCLUSIONS: The conventional 2D echocardiography could effectively reflect variation process of LVDF in AS patients after TAVI. For LVDD classification, obvious differences resulted by the 2009 and updated recommendations were found, and more patients can be regarded as benefiting from TAVI by 2016.


Asunto(s)
Estenosis de la Válvula Aórtica/cirugía , Válvula Aórtica/cirugía , Ecocardiografía/normas , Guías como Asunto , Reemplazo de la Válvula Aórtica Transcatéter/métodos , Función Ventricular Izquierda/fisiología , Anciano , Anciano de 80 o más Años , Válvula Aórtica/diagnóstico por imagen , Estenosis de la Válvula Aórtica/diagnóstico , Estenosis de la Válvula Aórtica/fisiopatología , Diástole , Femenino , Humanos , Masculino , Estudios Retrospectivos
13.
Cardiovasc Ultrasound ; 18(1): 41, 2020 Oct 13.
Artículo en Inglés | MEDLINE | ID: mdl-33050922

RESUMEN

BACKGROUND: The quantification of tricuspid regurgitation(TR) using three-dimensional(3D) proximal isovelocity surface area (PISA) derived effective regurgitant orifice area (EROA) is feasible in functional TR. The aim of our study was to explore the diagnostic accuracy and utility of 3D PISA EROA in a larger population of different etiologies. METHODS: One hundred and seven patients with confirmed TR underwent 2D and 3D transthoracic echocardiography (TTE). 3D PISA EROA was calculated and EROA derived from 3D regurgitant volume (Rvol) was used as the reference. RESULTS: 3D PISA EROA showed better correlation in primary TR than in functional TR(r = 0.897, P < 0.01). 3D PISA EROA differentiated severe TR with comparable accuracy in patients with primary and functional etiology (Z-value 16.506 vs 21.202), but with different cut-offs (0.49cm2 vs. 0.41 cm2). The chi-square value for incorporated clinical symptoms, positive echocardiographic results and 3D PISA EROA to grade severe TR was higher than only included clinical symptoms or incorporated clinical symptoms and positive echocardiographic results (chi-square value 137.233, P < 0.01). CONCLUSION: TR quantification using 3D PISA EROA is feasible and accurate under different etiologies. It has incremental diagnostic value for evaluating severe TR.


Asunto(s)
Ecocardiografía Tridimensional/métodos , Insuficiencia de la Válvula Tricúspide/diagnóstico por imagen , Adulto , Anciano , Femenino , Humanos , Interpretación de Imagen Asistida por Computador , Masculino , Persona de Mediana Edad , Estudios Prospectivos , Reproducibilidad de los Resultados , Sensibilidad y Especificidad , Índice de Severidad de la Enfermedad , Insuficiencia de la Válvula Tricúspide/fisiopatología
14.
Echocardiography ; 37(11): 1828-1837, 2020 11.
Artículo en Inglés | MEDLINE | ID: mdl-33007129

RESUMEN

BACKGROUND: The aim of this study was to investigate the utility of perimeter-derived diameter (PDD) measured by three-dimensional (3D) transesophageal echocardiography (TEE) in predicting the size of left atrial appendage (LAA) occluder. METHODS AND RESULTS: Left atrial appendage landing zone diameter (LZD) was measured by two-dimensional (2D) TEE, 3DTEE, and digital subtraction angiography (DSA) as LZD-2Dmax, LZD-2Dmean, LZD-3Dmax, LZD-3Dmean, LZD-PDD, LZD-DSAmax, respectively, before and during transcatheter LAA closure with Watchman devices in 100 patients. A difference of one or more device size intervals between the predicted size and the size actually implanted was defined as mismatching. Seventy-eight patients were followed up by TEE to obtain occluder compression ratio. The correlation between LZD and the final implanted occluder size was 0.559, 0.641, 0.754, 0.760, 0.782, and 0.848 for LZD-2Dmax, LZD-2Dmean, LZD-3Dmax, LZD-3Dmean, LZD-PDD and LZD-DSAmax, respectively (P < .001). Matching ratio between the size predicted by retrospective measurements of LZD and the device size actually implanted was 65%, 57%, 66%, 63%, 70%, and 83% for LZD-2Dmax, LZD-2Dmean, LZD-3Dmax, LZD-3Dmean, LZD-PDD and LZD-DSAmax, respectively. There was no significant difference in LZD value, matching ratio, and compression ratio between the patients with eccentric and noneccentric LAA landing zone (P > .05). Compression ratio of the mismatching subjects was higher than that in the matching subjects when evaluated by LZD-2Dmean, LZD-3Dmean, and LZD-PDD (P < .05). CONCLUSIONS: Landing zone diameter derived from LAA perimeter measured by preprocedure 3DTEE showed reference value for LAA occluder size selection, providing superior correlation and matching ratio with the final implanted size and indicating the adjustment of oversizing.


Asunto(s)
Apéndice Atrial , Fibrilación Atrial , Ecocardiografía Tridimensional , Dispositivo Oclusor Septal , Apéndice Atrial/diagnóstico por imagen , Apéndice Atrial/cirugía , Cateterismo Cardíaco , Ecocardiografía Transesofágica , Humanos , Valores de Referencia , Estudios Retrospectivos , Resultado del Tratamiento
15.
Acta Cardiol Sin ; 36(6): 620-625, 2020 Nov.
Artículo en Inglés | MEDLINE | ID: mdl-33235418

RESUMEN

BACKGROUND: A new technique has been developed for treating mitral regurgitation (MR) via a transapical approach, which encompasses an easy-to-use leaflet clamp and a smaller-sized delivery system (14F-16F). OBJECTIVES: We aimed to evaluate the effectiveness of this device in a porcine model of acute MR. METHODS: Acute MR was induced in 36 anesthetized porcine subjects by severing the chordae supporting the corresponding segment of the leaflet. The ValveClamp system was then transapically implanted on the prolapsing segment under epicardial echocardiographic guidance. Echocardiographic assessments were performed before and after the transapical interventions. All of the animals were killed 30 days after the procedure to verify the proper location of the implanted devices. RESULTS: Epicardial echocardiography revealed severe MR (n = 26) or moderate to severe MR (n = 10) in the pig model of acute MR. Overt MR reduction was observed following the procedure through echocardiography; residual MR was absent in 10 cases, mild in 17 cases, and moderate in 9 cases. There was no evidence of mitral stenosis at the end of the procedure in terms of mitral valve area and mitral valve pressure gradient. Autopsy demonstrated that all ValveClamp devices were precisely placed to clamp the prolapsing segment of the mitral valve. CONCLUSIONS: Transapical implantation of the ValveClamp device under epicardial echocardiographic guidance was effective and safe in reducing acutely induced MR in this pig model. It is potentially applicable as a novel user-friendly transcatheter edge-to-edge mitral valve repair device for the treatment of MR in humans.

16.
Microcirculation ; 26(1): e12509, 2019 01.
Artículo en Inglés | MEDLINE | ID: mdl-30365186

RESUMEN

OBJECTIVE: This study aimed to determine whether STE could help detect subclinical myocardial dysfunction in patients with CSFP. METHODS: Sixty patients with CSFP confirmed by CAG and 51 controls with normal coronary flow were prospectively enrolled. Coronary angiographic data and conventional and speckle tracking echocardiographic parameters of the LV and RV were obtained for every subject. RESULTS: Compared with controls, CSFP patients presented with higher BMI and TG levels, but lower HDL-C levels. Conventional echocardiographic parameters of biventricular systolic and diastolic function did not differ between the two groups (all P > 0.05). The GLS of the LV and RV was significantly impaired in CSFP patients compared with that in controls (-19.03% vs -21.42%, P < 0.001 and -19.72% vs -22.96%, P = 0.001, respectively). The myocardial impairment pattern of CSFP patients was homogenous in the RV and heterogeneous in the LV, where only endo- and mid-myocardial layers were affected. LV-GLS and RV-GLS were found to be well correlated with mTFC and HDL-C in CSFP groups (r = 0.463 vs r = 0.439; r = -0.569 vs r = -0.552, all P < 0.05). ROC curve analysis demonstrated that LV-GLS-endo had the highest AUC (0.867, P < 0.001) for predicting subclinical myocardial impairment in CSFP patients. CONCLUSIONS: Subclinical myocardial systolic dysfunction occurs in both ventricles, and GLS could be an effective method to detect early-stage myocardial impairment in patients with CSFP.


Asunto(s)
Cardiomiopatías/diagnóstico por imagen , Ecocardiografía/métodos , Fenómeno de no Reflujo/diagnóstico por imagen , Adulto , Área Bajo la Curva , Fenómenos Biomecánicos , Estudios de Casos y Controles , Colesterol/sangre , HDL-Colesterol/sangre , Enfermedad Coronaria , Femenino , Ventrículos Cardíacos/fisiopatología , Humanos , Masculino , Persona de Mediana Edad
17.
Catheter Cardiovasc Interv ; 93(7): 1354-1360, 2019 06 01.
Artículo en Inglés | MEDLINE | ID: mdl-30443976

RESUMEN

OBJECTIVES: The present study was performed to evaluate the feasibility and safety of the ValveClamp system for transcatheter edge-to-edge mitral valve repair in a porcine model. BACKGROUND: The ValveClamp system is a novel, transapically delivered edge-to-edge mitral valve repair system designed for ease of operation. METHODS: Thirteen young adult swine were enrolled in the study. The procedure was performed via the transapical approach under epicardial echocardiography guidance. RESULTS: The acute procedure success rate was 92.3% (12/13). The catheter manipulation time was just 18.5 ± 8.2 min. Four pigs were explanted on the 14th day after the procedure. One pig died at the 20th day because of pneumonia. The other eight pigs lived to the study endpoint (140 days). No pig had severe mitral valve dysfunction. The gross observation showed that the clamp device was securely attached and created a double-orifice mitral valve in all pigs except the failed one. In the eight pigs living to the endpoint, the clamp device was noted to be completely endothelialized. None of the 13 pigs developed infective endocarditis, thrombosis, thromboembolism, or valve impairment. In two pigs for which mitral regurgitation (MR) was created, the degree of MR was reduced from severe to trace after the device implantation. CONCLUSIONS: It was feasible and safe to use ValveClamp to perform a catheter-mediated edge-to-edge mitral valve repair in a porcine model. This system is potentially applicable as a novel user-friendly system for the treatment of MR.


Asunto(s)
Cateterismo Cardíaco/instrumentación , Implantación de Prótesis de Válvulas Cardíacas/instrumentación , Prótesis Valvulares Cardíacas , Insuficiencia de la Válvula Mitral/cirugía , Válvula Mitral/cirugía , Animales , Cateterismo Cardíaco/efectos adversos , Modelos Animales de Enfermedad , Estudios de Factibilidad , Implantación de Prótesis de Válvulas Cardíacas/efectos adversos , Hemodinámica , Humanos , Masculino , Ensayo de Materiales , Válvula Mitral/diagnóstico por imagen , Válvula Mitral/fisiopatología , Insuficiencia de la Válvula Mitral/diagnóstico por imagen , Insuficiencia de la Válvula Mitral/fisiopatología , Diseño de Prótesis , Sus scrofa
18.
Int Heart J ; 60(3): 586-592, 2019 May 30.
Artículo en Inglés | MEDLINE | ID: mdl-31019177

RESUMEN

Previous studies reported a controversial left ventricular (LV) function impairment and pathophysiology in patients with coronary slow flow (CSF). Greater arterial load has been shown to increase aortic impedance and endothelial shear stress, potentially affecting coronary anatomy and function. We investigated LV systolic function by a new layer-specific strain technology and assessed the association between pulsatile arterial load and contractility.A total of 70 patients with CSF and 50 controls with normal coronary angiography were included in the study. Layer-specific longitudinal and circumferential strains were assessed from endocardium, mid-myocardium, and epicardium (global longitudinal strain (GLS)-endo, GLS-mid, GLS-epi and GCS-endo, GCS-mid, GCS-epi) by two-dimensional speckle tracking imaging (2D-STI). Pulsatile arterial load was estimated by indexed arterial compliance (ACI). Layer-specific GLS showed a decreasing gradient from the endocardium to the epicardium in both the controls and CSF group. GLS-endo and GLS-mid in the CSF group were significantly lower than the control group (all P < 0.05). Layer-specific longitudinal strain showed a good correlation with the number of affected coronary arteries (all P < 0.05) and the mean thrombolysis in the myocardial infarction frame count (TFC) (all P < 0.05). ACI was lower in patients with CSF (P = 0.005), and ACI was correlated negatively with layer-specific GLS (all P < 0.05).Layer-specific evaluation of the LV provides an understanding of the layer-specific properties of the LV wall and the possible process of the LV impairment in patients with CSF. Greater pulsatile arterial load, as manifested by a lower ACI, is coupled with worse LV longitudinal function in patients with CSF.


Asunto(s)
Vasos Coronarios/diagnóstico por imagen , Vasos Coronarios/fisiopatología , Ventrículos Cardíacos/diagnóstico por imagen , Ventrículos Cardíacos/fisiopatología , Adulto , Anciano , Angiocardiografía , Ecocardiografía , Femenino , Humanos , Masculino , Persona de Mediana Edad , Estudios Prospectivos , Curva ROC , Función Ventricular Izquierda
20.
J Heart Valve Dis ; 26(4): 437-446, 2017 07.
Artículo en Inglés | MEDLINE | ID: mdl-29302943

RESUMEN

BACKGROUND AND AIM OF THE STUDY: The functions of the left ventricle and left atrium are closely associated with the outcomes of surgically treated patients with severe mitral regurgitation (MR). However, both parameters were overestimated in the presence of MR. The present study integrated the left atrium and left ventricle as the left heart (LH) to eliminate the influence of MR within the integrated structure. The study aim was to explore whether the emptying fraction of the LH is a load-independent parameter for patients with MR. METHODS: A total of 52 patients with isolated organic MR was enrolled as a patient group, and 48 age- and gender-matched healthy subjects as a control group. The left atrial emptying fraction (LAEF) and left ventricular ejection fraction (LVEF) were evaluated using apical four-chamber views. The global volume of the LH was calculated as the sum of left atrial (LA) and left ventricular (LV) volumes. The LH emptying fraction (LHEF) was assessed according to the volume-time curve of the LH. All patients underwent echocardiography one day before and within one week after surgery. RESULTS: The LA, LV and LH volumes were each increased in the patient group (p <0.05). The LVEF of the patient group was comparable to that of controls before surgery (p >0.05), and fell by 10% after surgery (p <0.05). The LAEF of the patient group fell before surgery and also suffered a 10% fall after surgery. Both, baseline and postoperative LHEF were decreased in the patient group (both p <0.05) and remained unchanged after the correction of MR (p >0.05). CONCLUSIONS: By integrating the left atrium and left ventricle as a whole, the LHEF avoided the influence of MR and proved to be a load-independent parameter for global left heart function in patients with MR.


Asunto(s)
Función del Atrio Izquierdo , Insuficiencia de la Válvula Mitral/fisiopatología , Válvula Mitral/fisiopatología , Volumen Sistólico , Función Ventricular Izquierda , Adulto , Anciano , Estudios de Casos y Controles , Ecocardiografía Doppler , Femenino , Humanos , Masculino , Persona de Mediana Edad , Válvula Mitral/diagnóstico por imagen , Válvula Mitral/cirugía , Insuficiencia de la Válvula Mitral/diagnóstico por imagen , Insuficiencia de la Válvula Mitral/cirugía , Valor Predictivo de las Pruebas , Estudios Prospectivos , Factores de Tiempo , Resultado del Tratamiento
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA