Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 29
Filtrar
Más filtros

Bases de datos
País/Región como asunto
Tipo del documento
Intervalo de año de publicación
1.
Ann Neurol ; 91(4): 548-560, 2022 04.
Artículo en Inglés | MEDLINE | ID: mdl-35084051

RESUMEN

OBJECTIVE: The objective of this study was to evaluate novel plasma p-tau231 and p-tau181, as well as Aß40 and Aß42 assays as indicators of tau and Aß pathologies measured with positron emission tomography (PET), and their association with cognitive change, in cognitively unimpaired older adults. METHODS: In a cohort of 244 older adults at risk of Alzheimer's disease (AD) owing to a family history of AD dementia, we measured single molecule array (Simoa)-based plasma tau biomarkers (p-tau231 and p-tau181), Aß40 and Aß42 with immunoprecipitation mass spectrometry, and Simoa neurofilament light (NfL). A subset of 129 participants underwent amyloid-ß (18 F-NAV4694) and tau (18 F-flortaucipir) PET assessments. We investigated plasma biomarker associations with Aß and tau PET at the global and voxel level and tested plasma biomarker combinations for improved detection of Aß-PET positivity. We also investigated associations with 8-year cognitive change. RESULTS: Plasma p-tau biomarkers correlated with flortaucipir binding in medial temporal, parietal, and inferior temporal regions. P-tau231 showed further associations in lateral parietal and occipital cortices. Plasma Aß42/40 explained more variance in global Aß-PET binding than Aß42 alone. P-tau231 also showed strong and widespread associations with cortical Aß-PET binding. Combining Aß42/40 with p-tau231 or p-tau181 allowed for good distinction between Aß-negative and -positive participants (area under the receiver operating characteristic curve [AUC] range = 0.81-0.86). Individuals with low plasma Aß42/40 and high p-tau experienced faster cognitive decline. INTERPRETATION: Plasma p-tau231 showed more robust associations with PET biomarkers than p-tau181 in presymptomatic individuals. The combination of p-tau and Aß42/40 biomarkers detected early AD pathology and cognitive decline. Such markers could be used as prescreening tools to reduce the cost of prevention trials. ANN NEUROL 2022;91:548-560.


Asunto(s)
Enfermedad de Alzheimer , Disfunción Cognitiva , Proteínas tau , Anciano , Enfermedad de Alzheimer/diagnóstico , Péptidos beta-Amiloides , Biomarcadores , Cognición , Disfunción Cognitiva/diagnóstico por imagen , Humanos , Tomografía de Emisión de Positrones , Proteínas tau/metabolismo
2.
Brain ; 144(10): 2964-2970, 2021 11 29.
Artículo en Inglés | MEDLINE | ID: mdl-33892504

RESUMEN

In vitro studies of autosomal dominant Alzheimer's disease implicate longer amyloid-ß peptides in disease pathogenesis; however, less is known about the behaviour of these mutations in vivo. In this cross-sectional cohort study, we used liquid chromatography-tandem mass spectrometry to analyse 66 plasma samples from individuals who were at risk of inheriting a mutation or were symptomatic. We tested for differences in amyloid-ß (Aß)42:38, Aß42:40 and Aß38:40 ratios between presenilin 1 (PSEN1) and amyloid precursor protein (APP) carriers. We examined the relationship between plasma and in vitro models of amyloid-ß processing and tested for associations with parental age at onset. Thirty-nine participants were mutation carriers (28 PSEN1 and 11 APP). Age- and sex-adjusted models showed marked differences in plasma amyloid-ß between genotypes: higher Aß42:38 in PSEN1 versus APP (P < 0.001) and non-carriers (P < 0.001); higher Aß38:40 in APP versus PSEN1 (P < 0.001) and non-carriers (P < 0.001); while Aß42:40 was higher in both mutation groups compared to non-carriers (both P < 0.001). Amyloid-ß profiles were reasonably consistent in plasma and cell lines. Within the PSEN1 group, models demonstrated associations between Aß42:38, Aß42:40 and Aß38:40 ratios and parental age at onset. In vivo differences in amyloid-ß processing between PSEN1 and APP carriers provide insights into disease pathophysiology, which can inform therapy development.


Asunto(s)
Enfermedad de Alzheimer/sangre , Enfermedad de Alzheimer/genética , Péptidos beta-Amiloides/sangre , Péptidos beta-Amiloides/genética , Presenilina-1/sangre , Presenilina-1/genética , Adulto , Enfermedad de Alzheimer/diagnóstico , Biomarcadores/sangre , Estudios de Cohortes , Estudios Transversales , Femenino , Genotipo , Humanos , Células Madre Pluripotentes Inducidas/metabolismo , Estudios Longitudinales , Masculino , Persona de Mediana Edad
3.
Brain ; 144(2): 434-449, 2021 03 03.
Artículo en Inglés | MEDLINE | ID: mdl-33479777

RESUMEN

Alzheimer's disease has a preclinical stage when cerebral amyloid-ß deposition occurs before symptoms emerge, and when amyloid-ß-targeted therapies may have maximum benefits. Existing amyloid-ß status measurement techniques, including amyloid PET and CSF testing, are difficult to deploy at scale, so blood biomarkers are increasingly considered for screening. We compared three different blood-based techniques-liquid chromatography-mass spectrometry measures of plasma amyloid-ß, and single molecule array (Simoa) measures of plasma amyloid-ß and phospho-tau181-to detect cortical 18F-florbetapir amyloid PET positivity (defined as a standardized uptake value ratio of >0.61 between a predefined cortical region of interest and eroded subcortical white matter) in dementia-free members of Insight 46, a substudy of the population-based British 1946 birth cohort. We used logistic regression models with blood biomarkers as predictors of amyloid PET status, with or without age, sex and APOE ε4 carrier status as covariates. We generated receiver operating characteristics curves and quantified areas under the curves to compare the concordance of the different blood tests with amyloid PET. We determined blood test cut-off points using Youden's index, then estimated numbers needed to screen to obtain 100 amyloid PET-positive individuals. Of the 502 individuals assessed, 441 dementia-free individuals with complete data were included; 82 (18.6%) were amyloid PET-positive. The area under the curve for amyloid PET status using a base model comprising age, sex and APOE ε4 carrier status was 0.695 (95% confidence interval: 0.628-0.762). The two best-performing Simoa plasma biomarkers were amyloid-ß42/40 (0.620; 0.548-0.691) and phospho-tau181 (0.707; 0.646-0.768), but neither outperformed the base model. Mass spectrometry plasma measures performed significantly better than any other measure (amyloid-ß1-42/1-40: 0.817; 0.770-0.864 and amyloid-ß composite: 0.820; 0.775-0.866). At a cut-off point of 0.095, mass spectrometry measures of amyloid-ß1-42/1-40 detected amyloid PET positivity with 86.6% sensitivity and 71.9% specificity. Without screening, to obtain 100 PET-positive individuals from a population with similar amyloid PET positivity prevalence to Insight 46, 543 PET scans would need to be performed. Screening using age, sex and APOE ε4 status would require 940 individuals, of whom 266 would proceed to scan. Using mass spectrometry amyloid-ß1-42/1-40 alone would reduce these numbers to 623 individuals and 243 individuals, respectively. Across a theoretical range of amyloid PET positivity prevalence of 10-50%, mass spectrometry measures of amyloid-ß1-42/1-40 would consistently reduce the numbers proceeding to scans, with greater cost savings demonstrated at lower prevalence.


Asunto(s)
Enfermedad de Alzheimer/sangre , Enfermedad de Alzheimer/diagnóstico , Péptidos beta-Amiloides/sangre , Fragmentos de Péptidos/sangre , Anciano , Enfermedad de Alzheimer/metabolismo , Biomarcadores/sangre , Diagnóstico Precoz , Femenino , Pruebas Hematológicas/métodos , Humanos , Masculino , Estudios Prospectivos , Sensibilidad y Especificidad
4.
Alzheimers Dement ; 16(11): 1493-1503, 2020 11.
Artículo en Inglés | MEDLINE | ID: mdl-32755010

RESUMEN

INTRODUCTION: Reference materials based on human cerebrospinal fluid were certified for the mass concentration of amyloid beta (Aß)1-42 (Aß42 ). They are intended to be used to calibrate diagnostic assays for Aß42 . METHODS: The three certified reference materials (CRMs), ERM-DA480/IFCC, ERM-DA481/IFCC and ERM-DA482/IFCC, were prepared at three concentration levels and characterized using isotope dilution mass spectrometry methods. Roche, EUROIMMUN, and Fujirebio used the three CRMs to re-calibrate their immunoassays. RESULTS: The certified Aß42 mass concentrations in ERM-DA480/IFCC, ERM-DA481/IFCC, and ERM-DA482/IFCC are 0.45, 0.72, and 1.22 µg/L, respectively, with expanded uncertainties (k = 2) of 0.07, 0.11, and 0.18 µg/L, respectively. Before re-calibration, a good correlation (Pearson's r > 0.97), yet large biases, were observed between results from different commercial assays. After re-calibration the between-assay bias was reduced to < 5%. DISCUSSION: The Aß42 CRMs can ensure the equivalence of results between methods and across platforms for the measurement of Aß42 .


Asunto(s)
Péptidos beta-Amiloides/líquido cefalorraquídeo , Inmunoensayo/normas , Calibración , Humanos , Inmunoensayo/métodos , Estándares de Referencia
5.
J Neurochem ; 151(4): 417-434, 2019 11.
Artículo en Inglés | MEDLINE | ID: mdl-30238462

RESUMEN

Neurodegenerative dementias constitute a broad group of diseases in which abnormally folded proteins accumulate in specific brain regions and result in tissue reactions that eventually cause neuronal dysfunction and degeneration. Depending on where in the brain this happens, symptoms appear which may be used to classify the disorders on clinical grounds. However, brain changes in neurodegenerative dementias start to accumulate many years prior to symptom onset and there is a poor correlation between the clinical picture and what pathology that is the most likely to cause it. Thus, novel drug candidates having disease-modifying effects that is targeting the underlying pathology and changes the course of the disease needs to be defined using objective biomarker-based measures since the clinical symptoms are often non-specific and overlap between different disorders. Furthermore, the treatment should ideally be initiated as soon as symptoms are evident or when biomarkers confirm an underlying pathology (pre-clinical phase of the disease) to reduce irreversible damage to, for example, neurons, synapses and axons. Clinical trials in the pre-clinical phase bring a greater importance to biomarkers since by definition the clinical effects are difficult or slow to discern in a population that is not yet clinically affected. Here, we discuss neuropathological changes that may underlie neurodegenerative dementias, including how they can be detected and quantified using currently available biofluid-based biomarkers and how more of them could be identified using targeted proteomics approaches. This article is part of the special issue "Proteomics".


Asunto(s)
Demencia , Enfermedades Neurodegenerativas , Proteómica/métodos , Péptidos beta-Amiloides/sangre , Péptidos beta-Amiloides/líquido cefalorraquídeo , Biomarcadores/sangre , Biomarcadores/líquido cefalorraquídeo , Proteínas de Unión al ADN/sangre , Proteínas de Unión al ADN/líquido cefalorraquídeo , Demencia/metabolismo , Demencia/patología , Demencia/fisiopatología , Humanos , Enfermedades Neurodegenerativas/metabolismo , Enfermedades Neurodegenerativas/patología , Enfermedades Neurodegenerativas/fisiopatología , alfa-Sinucleína/sangre , alfa-Sinucleína/líquido cefalorraquídeo , Proteínas tau/sangre , Proteínas tau/líquido cefalorraquídeo
6.
Clin Chem Lab Med ; 56(12): 2058-2066, 2018 11 27.
Artículo en Inglés | MEDLINE | ID: mdl-29949507

RESUMEN

BACKGROUND: The core Alzheimer's disease cerebrospinal fluid (CSF) biomarkers total tau (T-tau), phosphorylated tau (P-tau), ß-amyloid 1-42 (Aß42) and ß-amyloid 1-40 (Aß40) are increasing in importance and are now part of the research criteria for the diagnosis of the disease. The main aim of this study is to evaluate whether a set of certified reference materials (CRMs) are commutable for Aß42 and to serve as a feasibility study for the other markers. This property is a prerequisite for the establishment of CRMs which will then be used by manufacturers to calibrate their assays against. Once the preanalytical factors have been standardized and proper selection criteria are available for subject cohorts this harmonization between methods will allow for universal cut-offs to be determined. METHODS: Thirty-four individual CSF samples and three different CRMs where analyzed for T-tau, P-tau, Aß42 and Aß40, using up to seven different commercially available methods. For Aß40 and Aß42 a mass spectrometry-based procedure was also employed. RESULTS: There were strong pairwise correlations between the different methods (Spearman's ρ>0.92) for all investigated analytes and the CRMs were not distinguishable from the individual samples. CONCLUSIONS: This study shows that the CRMs are commutable for the different assays for Aß42. For the other analytes the results show that it would be feasible to also produce CRMs for these. However, additional studies are needed as the concentration interval for the CRMs were selected based on Aß42 concentrations only and did in general not cover satisfactory large concentration intervals for the other analytes.


Asunto(s)
Péptidos beta-Amiloides/líquido cefalorraquídeo , Inmunoensayo/normas , Fragmentos de Péptidos/líquido cefalorraquídeo , Proteínas tau/líquido cefalorraquídeo , Biomarcadores/líquido cefalorraquídeo , Humanos , Estándares de Referencia
7.
Expert Rev Proteomics ; 14(11): 1007-1020, 2017 11.
Artículo en Inglés | MEDLINE | ID: mdl-28942688

RESUMEN

INTRODUCTION: Alzheimer's disease (AD) is a neurodegenerative disease affecting the brain. Today there are three cerebrospinal fluid (CSF) biomarkers, amyloid-ß consisting of 42 amino acids (Aß42), total-tau (t-tau) and phosphorylated-tau (p-tau), which combined have sensitivity and specificity figures around 80%. However, pathological studies have shown that comorbidity is a common feature in AD and that the three currently used CSF biomarkers do not optimally reflect the activity of the disease process. Thus, additional markers are needed. Areas covered: In the present review, we screened PubMed for articles published the last five years (2012-2017) for proteomic studies in CSF with the criteria that AD had to be included as one of the diagnostic groups. Based on inclusion criteria, 28 papers were included reporting in total 224 biomarker-data that were altered in AD compared to control. Both mass spectrometry and multi-panel immunoassays were considered as proteomic studies. Expert commentary: A large number of pilot studies have been reported but so far there is a lack of replicated findings and to date no CSF biomarker discovered in proteomic studies has reached the clinic to aid in the diagnostic work-up of patients with cognitive impairment.


Asunto(s)
Enfermedad de Alzheimer/líquido cefalorraquídeo , Péptidos beta-Amiloides/líquido cefalorraquídeo , Proteómica , Proteínas tau/líquido cefalorraquídeo , Biomarcadores/líquido cefalorraquídeo , Humanos , Inmunoensayo , Espectrometría de Masas , Sensibilidad y Especificidad
8.
Brain ; 139(Pt 9): 2540-53, 2016 09.
Artículo en Inglés | MEDLINE | ID: mdl-27401520

RESUMEN

The aim of this study was to assess the agreement between data on cerebral amyloidosis, derived using Pittsburgh compound B positron emission tomography and (i) multi-laboratory INNOTEST enzyme linked immunosorbent assay derived cerebrospinal fluid concentrations of amyloid-ß42; (ii) centrally measured cerebrospinal fluid amyloid-ß42 using a Meso Scale Discovery enzyme linked immunosorbent assay; and (iii) cerebrospinal fluid amyloid-ß42 centrally measured using an antibody-independent mass spectrometry-based reference method. Moreover, we examined the hypothesis that discordance between amyloid biomarker measurements may be due to interindividual differences in total amyloid-ß production, by using the ratio of amyloid-ß42 to amyloid-ß40 Our study population consisted of 243 subjects from seven centres belonging to the Biomarkers for Alzheimer's and Parkinson's Disease Initiative, and included subjects with normal cognition and patients with mild cognitive impairment, Alzheimer's disease dementia, frontotemporal dementia, and vascular dementia. All had Pittsburgh compound B positron emission tomography data, cerebrospinal fluid INNOTEST amyloid-ß42 values, and cerebrospinal fluid samples available for reanalysis. Cerebrospinal fluid samples were reanalysed (amyloid-ß42 and amyloid-ß40) using Meso Scale Discovery electrochemiluminescence enzyme linked immunosorbent assay technology, and a novel, antibody-independent, mass spectrometry reference method. Pittsburgh compound B standardized uptake value ratio results were scaled using the Centiloid method. Concordance between Meso Scale Discovery/mass spectrometry reference measurement procedure findings and Pittsburgh compound B was high in subjects with mild cognitive impairment and Alzheimer's disease, while more variable results were observed for cognitively normal and non-Alzheimer's disease groups. Agreement between Pittsburgh compound B classification and Meso Scale Discovery/mass spectrometry reference measurement procedure findings was further improved when using amyloid-ß42/40 Agreement between Pittsburgh compound B visual ratings and Centiloids was near complete. Despite improved agreement between Pittsburgh compound B and centrally analysed cerebrospinal fluid, a minority of subjects showed discordant findings. While future studies are needed, our results suggest that amyloid biomarker results may not be interchangeable in some individuals.


Asunto(s)
Péptidos beta-Amiloides/metabolismo , Compuestos de Anilina , Biomarcadores/metabolismo , Disfunción Cognitiva/metabolismo , Demencia/metabolismo , Tiazoles , Anciano , Péptidos beta-Amiloides/líquido cefalorraquídeo , Biomarcadores/líquido cefalorraquídeo , Disfunción Cognitiva/líquido cefalorraquídeo , Disfunción Cognitiva/diagnóstico por imagen , Demencia/líquido cefalorraquídeo , Demencia/diagnóstico por imagen , Ensayo de Inmunoadsorción Enzimática , Europa (Continente) , Femenino , Humanos , Masculino , Espectrometría de Masas , Persona de Mediana Edad , Fragmentos de Péptidos/líquido cefalorraquídeo , Tomografía de Emisión de Positrones
9.
J Neurochem ; 139(4): 651-658, 2016 11.
Artículo en Inglés | MEDLINE | ID: mdl-27579672

RESUMEN

A clinical diagnosis of Alzheimer's disease is currently made on the basis of results from cognitive tests in combination with medical history and general clinical evaluation, but the peptide amyloid-beta (Aß) in cerebrospinal fluid (CSF) is increasingly used as a biomarker for amyloid pathology in clinical trials and in recently proposed revised clinical criteria for Alzheimer's disease. Recent analytical developments have resulted in mass spectrometry (MS) reference measurement procedures for absolute quantification of Aß1-42 in CSF. The CSF Aß1-42 /Aß1-40 ratio has been suggested to improve the detection of cerebral amyloid deposition, by compensating for inter-individual variations in total Aß production. Our aim was to cross-validate the reference measurement procedure as well as the Aß1-42 /Aß1-40 and Aß1-42 /Aß1-38 ratios in CSF, measured by high-resolution MS, with the cortical level of Aß fibrils as measured by amyloid (18 F-flutemetamol) positron emission tomography (PET). We included 100 non-demented patients with cognitive symptoms from the Swedish BioFINDER study, all of whom had undergone both lumbar puncture and 18 F-flutemetamol PET. Comparing CSF Aß1-42 concentrations with 18 F-flutemetamol PET showed high concordance with an area under the receiver operating characteristic curve of 0.85 and a sensitivity and specificity of 82% and 81%, respectively. The ratio of Aß1-42 /Aß1-40 or Aß1-42 /Aß1-38 significantly improved concordance with an area under the receiver operating characteristic curve of 0.95 and a sensitivity and specificity of 96% and 91%, respectively. These results show that the CSF Aß1-42 /Aß1-40 and Aß1-42 /Aß1-38 ratios using the described MS method are strongly associated with cortical Aß fibrils measured by 18 F-flutemetamol PET.


Asunto(s)
Enfermedad de Alzheimer/líquido cefalorraquídeo , Enfermedad de Alzheimer/diagnóstico por imagen , Péptidos beta-Amiloides/líquido cefalorraquídeo , Amiloide/líquido cefalorraquídeo , Fragmentos de Péptidos/líquido cefalorraquídeo , Tomografía de Emisión de Positrones , Enfermedad de Alzheimer/epidemiología , Biomarcadores/líquido cefalorraquídeo , Humanos , Estudios Longitudinales , Estudios Prospectivos , Estándares de Referencia , Suecia/epidemiología
10.
Clin Chem Lab Med ; 54(7): 1177-91, 2016 Jul 01.
Artículo en Inglés | MEDLINE | ID: mdl-26495928

RESUMEN

BACKGROUND: The cerebrospinal fluid (CSF) amyloid-ß (Aß42) peptide is an important biomarker for Alzheimer's disease (AD). Variability in measured Aß42 concentrations at different laboratories may be overcome by standardization and establishing traceability to a reference system. Candidate certified reference materials (CRMs) are validated herein for this purpose. METHODS: Commutability of 16 candidate CRM formats was assessed across five CSF Aß42 immunoassays and one mass spectrometry (MS) method in a set of 48 individual clinical CSF samples. Promising candidate CRM formats (neat CSF and CSF spiked with Aß42) were identified and subjected to validation across eight (Elecsys, EUROIMMUN, IBL, INNO-BIA AlzBio3, INNOTEST, MSD, Simoa, and Saladax) immunoassays and the MS method in 32 individual CSF samples. Commutability was evaluated by Passing-Bablok regression and the candidate CRM termed commutable when found within the prediction interval (PI). The relative distance to the regression line was assessed. RESULTS: The neat CSF candidate CRM format was commutable for almost all method comparisons, except for the Simoa/MSD, Simoa/MS and MS/IBL where it was found just outside the 95% PI. However, the neat CSF was found within 5% relative distance to the regression line for MS/IBL, between 5% and 10% for Simoa/MS and between 10% and 15% for Simoa/MSD comparisons. CONCLUSIONS: The neat CSF candidate CRM format was commutable for 33 of 36 method comparisons, only one comparison more than expected given the 95% PI acceptance limit. We conclude that the neat CSF candidate CRM can be used for value assignment of the kit calibrators for the different Aß42 methods.


Asunto(s)
Péptidos beta-Amiloides/líquido cefalorraquídeo , Biomarcadores/líquido cefalorraquídeo , Inmunoensayo/normas , Humanos , Límite de Detección , Estándares de Referencia , Espectrometría de Masas en Tándem
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA