Artif Organs ; 2024 Apr 23.
Artículo en Inglés | MEDLINE | ID: mdl-38651352

RESUMEN

BACKGROUND: In vitro assessment is mandatory for artificial heart valve development. This study aims to investigate the effects of pulse duplicator features on valve responsiveness, conduct a sensitivity analysis across valve prosthesis types, and contribute on the development of versatile pulse duplicator systems able to perform reliable prosthetic aortic valve assessment under physiologic hemodynamic conditions. METHODS: A reference pulse duplicator was established based on literature. Further optimization process led to new designs that underwent a parametric study, also involving different aortic valve prostheses. These designs were evaluated on criteria such as mean pressure differential and pulse pressure (assessed from high-fidelity pressure measurements), valve opening and closing behavior, flow, and regurgitation. Finally, the resulting optimized setup was tested under five different hemodynamic settings simulating a range of physiologic and pathologic conditions. RESULTS: The results show that both, pulse duplicator design and valve type significantly influence aortic and ventricular pressure, flow, and valve kinematic response. The optimal design comprised key features such as a compliance chamber and restrictor for diastolic pressure maintenance and narrow pulse pressure. Additionally, an atrial reservoir was included to prevent atrial-aortic interference, and a bioprosthetic valve was used in mitral position to avoid delayed valve closing effects. CONCLUSION: This study showed that individual pulse duplicator features can have a significant effect on valve's responsiveness. The optimized versatile pulse duplicator replicated physiologic and pathologic aortic valve hemodynamic conditions, serving as a reliable characterization tool for assessing and optimizing aortic valve performance.

2.
Sensors (Basel) ; 21(7)2021 Mar 31.
Artículo en Inglés | MEDLINE | ID: mdl-33807201

RESUMEN

In this study, silica glass, optical fiber Bragg gratings (FBGs) are used for torque-induced strain monitoring in carbon fiber reinforced polymer (CFRP) hollow shafts toward the development of a methodology for structural load monitoring. Optical fibers with gratings are embedded during shaft manufacturing, by an industrial filament winding process, along different orientations with respect to its central axis and surface mounted after production. Experimental results are supported by numerical modeling of the shaft with appropriate boundary conditions and homogenized material properties. For an applied torque up to 800 Nm, the strain sensitivity of an embedded grating positioned along the reinforcing fibers' direction winded under 55° is in the order of 3.6 pm/Nm, while this value is more than 4× times higher than the other examined orientations. The study also shows that surface-mounted optical fiber Bragg gratings along the reinforcing carbon fibers' direction perform equally well in monitoring strains in composite shafts under torque.

3.
Biomater Adv ; 146: 213288, 2023 Mar.
Artículo en Inglés | MEDLINE | ID: mdl-36731379

RESUMEN

Polymers have the potential to replace metallic or bioprosthetic heart valve components due to superior durability and inertness while allowing for native tissue-like flexibility. Despite these appealing properties, certain polymers such as polyetheretherketone (PEEK) have issues with hemocompatibility, which have previously been addressed through assorted complex processes. In this paper, we explore the enhancement of PEEK hemocompatibility with polymer crystallinity. Amorphous, semi-crystalline and crystalline PEEK are investigated in addition to a highly crystalline carbon fiber (CF)/PEEK composite material (CFPEEK). The functional group density of the PEEK samples is determined, showing that higher crystallinity results in increased amount of surface carbonyl functional groups. The increase of crystallinity (and negatively charged groups) appears to cause significant reductions in platelet adhesion (33 vs. 1.5 % surface coverage), hemolysis (1.55 vs. 0.75 %∙cm-2), and thrombin generation rate (4840 vs. 1585 mU/mL/min/cm2). In combination with the hemocompatibility study, mechanical characterization demonstrates that tailoring crystallinity is a simple and effective method to control both hemocompatibility and mechanical performance of PEEK. Furthermore, the results display that CFPEEK composite performed very well in all categories due to its enhanced crystallinity and complete carbon encapsulation, allowing the unique properties of CFPEEK to empower new concepts in cardiovascular device design.


Asunto(s)
Polietilenglicoles , Polímeros , Benzofenonas , Cetonas/química , Ensayo de Materiales , Polietilenglicoles/química , Polímeros/uso terapéutico , Vasos Sanguíneos/trasplante
4.
iScience ; 25(10): 105157, 2022 Oct 21.
Artículo en Inglés | MEDLINE | ID: mdl-36185369

RESUMEN

In this backstory, researchers from Swiss Federal Institute of Technology (ETH Zurich) who initiated an interdisciplinary program to generate innovative solutions for different cardiovascular diseases, such as myocardial infarction, valvular replacement, and movement-based rehabilitation therapy, discuss the benefits and challenges of interdisciplinary research.