Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 79
Filtrar
Más filtros

País/Región como asunto
Intervalo de año de publicación
1.
Perfusion ; 37(1): 69-77, 2022 Jan.
Artículo en Inglés | MEDLINE | ID: mdl-33325335

RESUMEN

INTRODUCTION: This study aimed to test a computer-driven cardiovascular model for the evaluation of the visceral flow during intra-aortic balloon pump (IABP) assistance. METHODS: The model includes a systemic and pulmonary circulation as well as a heart contraction model. The straight polyurethane tube aorta had a single visceral while four windkessel components mimicked resistance compliance of the brachiocephalic, renal and sub-mesenteric, pulmonary, and systemic circulation. Twelve flow probes were placed in the circuit to measure pressures and flows with the IABP on and off. RESULTS: With the balloon off, the meantime to reach the steady state was 48 ± 16 s; with the balloon on, this figure was 178 ± 20 s. The stability of pressure and flow signals was obtained after 72 ± 11 min. The number of cycles of stability of the system was 93 [86-103]. Measurements were reliable either with samples of 10 or 20 beats. Bland Altman method demonstrated the reliability of measurements. Finally, all measurements were comparable to published in vivo data. CONCLUSION: The presented mock circulation was reliable and gave values with high accuracy both at baseline and during mechanical assistance. This system allows evaluation of the mesenteric flow during IABP, under different clinical/hemodynamic conditions. Nonetheless, its translational potential needs to be further evaluated.


Asunto(s)
Contrapulsación , Corazón Auxiliar , Aorta , Circulación Coronaria , Hemodinámica , Humanos , Contrapulsador Intraaórtico/métodos , Reproducibilidad de los Resultados
2.
Crit Care ; 25(1): 107, 2021 03 17.
Artículo en Inglés | MEDLINE | ID: mdl-33731186

RESUMEN

BACKGROUND: Single- (SL) and double-lumen (DL) catheters are used in clinical practice for veno-venous extracorporeal membrane oxygenation (V-V ECMO) therapy. However, information is lacking regarding the effects of the cannulation on neurological complications. METHODS: A retrospective observational study based on data from the Extracorporeal Life Support Organization (ELSO) registry. All adult patients included in the ELSO registry from 2011 to 2018 submitted to a single run of V-V ECMO were analyzed. Propensity score (PS) inverse probability of treatment weighting estimation for multiple treatments was used. The average treatment effect (ATE) was chosen as the causal effect estimate of outcome. The aim of the study was to evaluate differences in the occurrence and the type of neurological complications in adult patients undergoing V-V ECMO when treated with SL or DL cannulas. RESULTS: From a population of 6834 patients, the weighted propensity score matching included 6245 patients (i.e., 91% of the total cohort; 4175 with SL and 20,270 with DL cannulation). The proportion of patients with at least one neurological complication was similar in the SL (306, 7.2%) and DL (189, 7.7%; odds ratio 1.10 [95% confidence intervals 0.91-1.32]; p = 0.33). After weighted propensity score, the ATE for the occurrence of least one neurological complication was 0.005 (95% CI - 0.009 to 0.018; p = 0.50). Also, the occurrence of specific neurological complications, including intracerebral hemorrhage, acute ischemic stroke, seizures or brain death, was similar between groups. Overall mortality was similar between patients with neurological complications in the two groups. CONCLUSIONS: In this large registry, the occurrence of neurological complications was not related to the type of cannulation in patients undergoing V-V ECMO.


Asunto(s)
Oxigenación por Membrana Extracorpórea/efectos adversos , Enfermedades del Sistema Nervioso/etiología , Adulto , Correlación de Datos , Oxigenación por Membrana Extracorpórea/métodos , Oxigenación por Membrana Extracorpórea/estadística & datos numéricos , Femenino , Humanos , Masculino , Persona de Mediana Edad , Enfermedades del Sistema Nervioso/fisiopatología , Puntaje de Propensión , Sistema de Registros/estadística & datos numéricos , Estudios Retrospectivos
3.
Thorac Cardiovasc Surg ; 69(7): 614-620, 2021 Oct.
Artículo en Inglés | MEDLINE | ID: mdl-33626589

RESUMEN

OBJECTIVE: The aim of this study was to investigate whether the use of off-pump coronary artery bypass (OPCAB) may enhance early outcomes in subjects with peripheral artery disease (PAD) undergoing coronary artery bypass grafting (CABG). METHODS: We employed a propensity-score (PS) method to compare early postoperative results of OPCAB and on-pump CABG patients with associated PAD. The study population consisted of 1,961 patients: 284 in the OPCAB and 1,677 in the on-pump CABG group. The inverse probability of treatment weighting was used as PS method. RESULTS: The incidence of death (1.2% [95% confidence interval, CI: -0.9 to 3.3%], p = 0.262), stroke (2.2% [95% CI: -1.4 to 5.7%], p = 0.235), acute kidney disease (1.5% [95% CI: -3.8 to 6.8%], p = 0.586), limb ischemia (3.2% [95% CI: -0.6 to 7.0%], p = 0.315), and low output syndrome (1.2% [95% CI: -0.9 to 3.3%], p = 0.262) did not differ between the two groups. On the other hand, the rate of cardiac death (1.2% [95% CI: -0.1 to 2.3%], p = 0.038) was significantly higher in on-pump CABG group. CONCLUSIONS: The OPCAB procedure considerably reduced the occurrence of cardiac death after coronary revascularization. This finding might suggest that the OPCAB procedure should be considered as the first option in patients with higher cardiovascular risk scores. Further research is warranted.


Asunto(s)
Puente de Arteria Coronaria Off-Pump , Enfermedad Arterial Periférica , Puente de Arteria Coronaria , Puente de Arteria Coronaria Off-Pump/efectos adversos , Muerte , Humanos , Enfermedad Arterial Periférica/diagnóstico por imagen , Enfermedad Arterial Periférica/cirugía , Resultado del Tratamiento
4.
J Card Surg ; 36(3): 1030-1039, 2021 Mar.
Artículo en Inglés | MEDLINE | ID: mdl-33336497

RESUMEN

BACKGROUND AND AIM: Classical and paradoxical low-flow, low-gradient (LFLG) aortic stenosis (AS) are the most challenging subtypes of AS. The current therapeutic options are aortic valve replacement (AVR) and conservative management: AVR promotes long-term survival but is invasive, while conservative management yields a poor prognosis but is noninvasive since it uses no aortic valve replacement (noAVR). The present meta-analysis investigated the rate of survival of patients with LFLG AS undergoing either AVR or noAVR interventions. METHODS: The meta-analysis compared the outcomes of AVR with those of noAVR in terms of patient survival. In both groups, a meta-regression was conducted to investigate the impact on patient survival of the left ventricular ejection fraction (LVEF), either preserved (paradoxical LFLG AS) or reduced (classical LFLG AS). RESULTS: The relative risk of survival between the AVR and noAVR groups was 1.99 [1.40, 2.82] (p = .0001), suggesting that survival tends to be better in AVR patients than in noAVR patients. The meta-regression revealed that a reduced LVEF may be related to a higher survival in AVR patients when compared to a preserved LVEF (p = .04). Finally, the analysis indicated that LVEF seems not to be prognostic of survival in noAVR patients (p = .18). CONCLUSIONS: Patients with LFLG AS have better survival if they undergo AVR. In AVR patients, reduced LVEF rather than preserved LVEF is related to better survival, whereas there seems to be no difference in prognostic value between reduced and preserved LVEF in noAVR patients.


Asunto(s)
Estenosis de la Válvula Aórtica , Implantación de Prótesis de Válvulas Cardíacas , Válvula Aórtica/diagnóstico por imagen , Válvula Aórtica/cirugía , Estenosis de la Válvula Aórtica/cirugía , Tratamiento Conservador , Humanos , Estudios Retrospectivos , Índice de Severidad de la Enfermedad , Volumen Sistólico , Resultado del Tratamiento , Función Ventricular Izquierda
5.
J Card Surg ; 35(3): 645-653, 2020 Mar.
Artículo en Inglés | MEDLINE | ID: mdl-31951676

RESUMEN

BACKGROUND AND AIMS: The main pathophysiological factor of chronic ischemic mitral regurgitation (MR) is the outward displacement of the papillary muscles (PMs) leading to leaflet tethering. For this reason, papillary muscle intervention (PMI) in combination with mitral ring annuloplasty (MRA) has recently been introduced into clinical practice to correct this displacement, and to reduce the recurrence of regurgitation. METHODS: A meta-analysis was conducted comparing the outcomes of PMI and MRA performed in combination vs MRA performed alone, in terms of MR recurrence and left ventricular reverse remodeling (LVRR). A meta-regression was carried out to investigate the impact of the type of PMI procedure on the outcomes. RESULTS: MR recurrence in patients undergoing both PMI and MRA was lower than in those who only had MRA (log incidence rate ratio, -0.66; lower-upper limits, -1.13 to 0.20; I2 = 0.0%; p = .44; Egger's test: intercept 0.35 [-0.78 to 1.51]; p = .42). The group with both PMI and MRA and that with only MRA showed a slightly higher reduction in left ventricular diameters (-5.94%; -8.75% to 3.13%,). However, in both groups, LVRR was <10%. No difference was detected between PM relocation/repositioning and papillary muscle approximation in terms of LVRR (p = .33). CONCLUSIONS: Using PMI and MRA together has a lower MR recurrence than using MRA alone. No significant LVRR was observed between the two groups nor between the PMI techniques employed.


Asunto(s)
Anuloplastia de la Válvula Mitral/métodos , Insuficiencia de la Válvula Mitral/cirugía , Músculos Papilares/cirugía , Anciano , Femenino , Humanos , Masculino , Persona de Mediana Edad , Recurrencia , Prevención Secundaria , Remodelación Ventricular
6.
Heart Lung Circ ; 29(10): 1502-1510, 2020 Oct.
Artículo en Inglés | MEDLINE | ID: mdl-32165084

RESUMEN

AIM: The aim was to use a propensity score-based analysis to determine the impact of peripheral artery disease (PAD) on early outcomes after coronary artery bypass surgery grafting (CABG) in patients with PAD. METHOD: We conducted a multicentre retrospective analysis of 11,311 consecutive patients who underwent CABG between 1997 and 2017. Patients with previous or concomitant vascular surgery were excluded. The main endpoints were death, stroke, and limb ischaemia requiring percutaneous or surgical revascularisation. Subgroup analyses were performed to test the interaction of PAD with concomitant factors. RESULTS: There was no difference in mortality in patients with and without PAD (p=0.06 and p=0.179, respectively). Patients with PAD had a greater incidence of stroke (p=0.04), acute kidney disease (p=0.003), and limb ischaemia requiring interventions (p<0.001) than those without PAD. The use of off-pump or no-touch aortic techniques did not influence the effect of PAD on the outcomes. Early mortality rate increased in patients with PAD when associated with long cardiopulmonary bypass, cross-clamp times (both p<0.001), and postoperative low cardiac output (p=0.01). CONCLUSIONS: The presence of PAD is associated, independently of other factors, with greater incidence of stroke, acute kidney disease, and limb ischaemia following CABG, irrespective of the technique employed. Operative mortality was greater in patients with PAD only when associated with long cardiopulmonary bypass and aortic cross-clamp times, and low cardiac output.


Asunto(s)
Puente de Arteria Coronaria/métodos , Enfermedad de la Arteria Coronaria/cirugía , Enfermedad Arterial Periférica/complicaciones , Puntaje de Propensión , Anciano , Enfermedad de la Arteria Coronaria/complicaciones , Femenino , Humanos , Incidencia , Italia/epidemiología , Masculino , Persona de Mediana Edad , Enfermedad Arterial Periférica/diagnóstico , Enfermedad Arterial Periférica/epidemiología , Pronóstico , Estudios Retrospectivos , Factores de Riesgo , Tasa de Supervivencia/tendencias , Resultado del Tratamiento
7.
Exp Physiol ; 104(5): 643-653, 2019 05.
Artículo en Inglés | MEDLINE | ID: mdl-30821049

RESUMEN

NEW FINDINGS: What is the central question of this study? Visceral ischaemia is one of the most feared complications during use of an intra-aortic balloon pump. Using an animal model, we measured the flows at the abdominal level directly and examined flow patterns to enable investigation of flow patterns during the use of the intra-aortic balloon pump. What is the main finding and its importance? We show that there is a significant balloon-related reduction in superior mesenteric flow in both early and mid-diastole. ABSTRACT: A number of previous studies have shown that blood flow in the visceral arteries is altered during intra-aortic balloon pump (IABP) treatment. We used a porcine model to analyse the pattern of blood flow into the visceral arteries during IABP use. For this purpose, we measured the superior mesenteric, right renal and left renal flows before and during IABP support, using surgically placed flowmeters surrounding these visceral arteries. The superior mesenteric flow significantly decreased in early diastole (P < 0.001) and in mid-diastole (P = 0.003 versus early diastole), whereas in late diastole it increased again (P < 0.001 versus mid-diastole). During systole, the flow was not significantly increased compared with late diastole (P = 0.51), but it was significantly lower than at baseline (both P < 0.001). Flows did not differ between right and left kidneys. Perfusion of either kidney did not change significantly in early diastole (P > 0.05), whereas it decreased significantly in mid-diastole (P < 0.001), rising dramatically in late diastole (P < 0.001) and with an additional slight increase in systole (P = 0.054). This study provides important insights into abdominal flows during intra-aortic pump counterpulsation. Furthermore, it supports the need to rethink the balloon design to avoid visceral ischaemia during circulatory assistance.


Asunto(s)
Contrapulsador Intraaórtico , Arteria Mesentérica Superior/fisiología , Circulación Renal/fisiología , Animales , Velocidad del Flujo Sanguíneo , Contrapulsación , Diástole/fisiología , Electrocardiografía , Hemodinámica , Monitoreo Fisiológico , Reología , Porcinos , Sístole/fisiología
8.
J Surg Oncol ; 120(4): 768-778, 2019 Sep.
Artículo en Inglés | MEDLINE | ID: mdl-31297837

RESUMEN

BACKGROUND AND OBJECTIVES: Lymphadenectomy during pulmonary metastasectomy (PM) is widely carried out. We assessed the potential benefit on patient survival and tumor recurrence of this practice. METHODS: One hundred eighty-one patients undergoing a first PM were studied. Eighty-six patients (47.5%) underwent lymphadenectomy (L+ group) whereas 95 (52.5%) did not undergo nodal harvesting (L-group). Main outcomes were overall survival (OS) and disease-free survival (DFS). Median follow-up was 25 months (interquartile range [IQR], 13-49). RESULTS: At follow-up 84 patients (46.4%) died, whereas 97 (53.6%) were still alive with recurrence in 78 patients (43%). There was no difference in 5-year survival (L+ 30.0% vs L- 43.2%; P = .87) or in the 5-year cumulative incidence of recurrence (L + 63.2% vs L-80%; P = .07) between the two groups. Multivariable analysis indicated that disease-free interval (DFI) less than 29 months (P < .001) and lung comorbidities (P = .003) were significant predictors of death. Metastases from non-small-cell lung cancer increased the risk of lung comorbidities by a factor of 19.8, whereas the risk of DFI less than 29 months was increased nearly 11-fold. Competing risk regression identified multiple metastases (P = .004), head/neck primary tumor (P = .009), and age less than 67 years (P = .024) as independent risk factors for recurrence. CONCLUSION: Associated lymphadenectomy showed not to give any additional advantage in terms of survival and recurrence after PM.


Asunto(s)
Carcinoma de Pulmón de Células no Pequeñas/mortalidad , Neoplasias Pulmonares/mortalidad , Escisión del Ganglio Linfático/mortalidad , Metastasectomía/mortalidad , Recurrencia Local de Neoplasia/mortalidad , Neumonectomía/mortalidad , Anciano , Carcinoma de Pulmón de Células no Pequeñas/patología , Carcinoma de Pulmón de Células no Pequeñas/cirugía , Femenino , Estudios de Seguimiento , Humanos , Neoplasias Pulmonares/patología , Neoplasias Pulmonares/cirugía , Masculino , Persona de Mediana Edad , Recurrencia Local de Neoplasia/patología , Recurrencia Local de Neoplasia/cirugía , Pronóstico , Factores de Riesgo , Tasa de Supervivencia
9.
BMC Nephrol ; 20(1): 371, 2019 10 16.
Artículo en Inglés | MEDLINE | ID: mdl-31619211

RESUMEN

BACKGROUND: This study was undertaken to compare the accuracy of chronic kidney disease-epidemiology collaboration (eGFRCKD-EPI) to modification of diet in renal disease (eGFRMDRD) and the Cockcroft-Gault formulas of Creatinine clearance (CCG) equations in predicting post coronary artery bypass grafting (CABG) mortality. METHODS: Data from 4408 patients who underwent isolated CABG over a 11-year period were retrieved from one institutional database. Discriminatory power was assessed using the c-index and comparison between the scores' performance was performed with DeLong, bootstrap, and Venkatraman methods. Calibration was evaluated with calibration curves and associated statistics. RESULTS: The discriminatory power was higher in eGFRCKD-EPI than eGFRMDRD and CCG (Area under Curve [AUC]:0.77, 0.55 and 0.52, respectively). Furthermore, eGFRCKD-EPI performed worse in patients with an eGFR ≤29 ml/min/1.73m2 (AUC: 0.53) while it was not influenced by higher eGFRs, age, and body size. In contrast, the MDRD equation was accurate only in women (calibration statistics p = 0.72), elderly patients (p = 0.53) and subjects with severe impairment of renal function (p = 0.06) whereas CCG was not significantly biased only in patients between 40 and 59 years (p = 0.6) and with eGFR 45-59 ml/min/1.73m2 (p = 0.32) or ≥ 60 ml/min/1.73m2 (p = 0.48). CONCLUSIONS: In general, CKD-EPI gives the best prediction of death after CABG with unsatisfactory accuracy and calibration only in patients with severe kidney disease. In contrast, the CG and MDRD equations were inaccurate in a clinically significant proportion of patients.


Asunto(s)
Puente de Arteria Coronaria/mortalidad , Tasa de Filtración Glomerular/fisiología , Complicaciones Posoperatorias/mortalidad , Insuficiencia Renal Crónica/mortalidad , Anciano , Puente de Arteria Coronaria/efectos adversos , Puente de Arteria Coronaria/tendencias , Femenino , Humanos , Masculino , Persona de Mediana Edad , Mortalidad/tendencias , Complicaciones Posoperatorias/diagnóstico , Complicaciones Posoperatorias/etiología , Valor Predictivo de las Pruebas , Insuficiencia Renal Crónica/diagnóstico , Insuficiencia Renal Crónica/cirugía , Estudios Retrospectivos
10.
J Card Surg ; 34(12): 1470-1477, 2019 Dec.
Artículo en Inglés | MEDLINE | ID: mdl-31536148

RESUMEN

BACKGROUND: We carried out a propensity score-based analysis on early outcomes after coronary artery bypass grafting (CABG) in patients with and without peripheral artery disease (PAD). MATERIALS AND METHODS: A total of 11 311 patients undergoing isolated CABG between 1997 and 2017 were included in the study. Patients were divided into two groups based on whether they were affected (n = 1961) or not affected (n = 9350) by PAD. Inverse probability of treatment weighting was employed to reduce confounding preoperative and operative variables. The main endpoints were death, cardiac death, stroke, and limb ischemia requiring percutaneous or surgical revascularization. RESULTS: The excellent balance was obtained, and the groups were very similar. For death and cardiac death, there were no differences between patients with and without PAD (P = .06 and P = .179, respectively). In contrast, PAD patients showed a higher incidence of stroke (P = .04), acute kidney disease (AKD) (P = .003) and limb ischemia requiring intervention (P < .001) than patients without PAD. CONCLUSIONS: The presence of peripheral arterial disease increases the incidence of postoperative stroke, AKD and limb ischemia requiring intervention, independent of patient characteristics, concomitant risk factors, surgical approaches, and techniques. Further larger studies are necessary to confirm our findings.


Asunto(s)
Lesión Renal Aguda/etiología , Puente de Arteria Coronaria , Enfermedad de la Arteria Coronaria/cirugía , Isquemia/etiología , Enfermedad Arterial Periférica/complicaciones , Complicaciones Posoperatorias/epidemiología , Accidente Cerebrovascular/etiología , Lesión Renal Aguda/epidemiología , Anciano , Puente de Arteria Coronaria/efectos adversos , Puente de Arteria Coronaria/mortalidad , Enfermedad de la Arteria Coronaria/complicaciones , Enfermedad de la Arteria Coronaria/mortalidad , Femenino , Humanos , Incidencia , Isquemia/epidemiología , Extremidad Inferior/irrigación sanguínea , Masculino , Persona de Mediana Edad , Puntaje de Propensión , Factores de Riesgo , Accidente Cerebrovascular/epidemiología , Resultado del Tratamiento
11.
J Card Surg ; 34(11): 1297-1304, 2019 Nov.
Artículo en Inglés | MEDLINE | ID: mdl-31472023

RESUMEN

BACKGROUND AND AIMS: We investigated neurological events, graft patency, major adverse cardiovascular events (MACEs), and mortality at 1 year following coronary artery bypass grafting (CABG) surgery using automated proximal anastomotic devices (APADs) and compared the overall rates with the current literature. METHODS: A systematic review of all available reports of APADs use in the literature was conducted. Cumulative incidence and 95% confidence interval (CI) were the main statistical indexes. Nine observational studies encompassing a total of 718 patients were included at the end of the selection process. RESULTS: The cumulative event rate of neurological complications was 4.8% (lower-upper limits: 2.8-8.0, P < .001; I2 = 72.907%, P = .002; Egger's test: intercept = -2.47, P = 0.16; Begg and Mazumdar test: τ = -0.20, p = 0.57). Graft patency was 90.5% (80.4 to 95.7, P < .001; I2 = 76.823%, P = .005; Egger's test: intercept = -3.04, P = .10; Begg and Mazumdar test: τ = -0.67, P = .17). Furthermore, the overall incidence of MACEs was 3.7% (1.3-10.4, P < .001; I2 = 51.556%, P = .103; Egger's test: intercept = -1.98, P = < .11; Begg and Mazumdar test: τ = -0.67, P = .17). Finally, mortality within 1 year was 5% (3.5-7, P < .001; I2 = 29.675%, P = .202; Egger's test: intercept = -0.91, P = .62; Begg and Mazumdar test: τ = -0.04, P = .88). CONCLUSIONS: APADs do not seem to be correlated with a reduction of either neurological events or mortality. By contrast, these tools showed satisfactory one-year graft patency and a low incidence of MACEs. Further research on this topic is warranted.


Asunto(s)
Puente de Arteria Coronaria , Puente de Arteria Coronaria/efectos adversos , Humanos , Resultado del Tratamiento
12.
Perfusion ; 34(7): 538-543, 2019 10.
Artículo en Inglés | MEDLINE | ID: mdl-30868943

RESUMEN

BACKGROUND: Extracorporeal membrane oxygenation constitutes a complex support modality, and accurate monitoring is required. An ideal monitoring system should promptly detect ECMO malfunctions and provide real-time information to optimize the patient-machine interactions. We tested a new volumetric capnometer which enables continuous monitoring of membrane lung carbon dioxide removal (V'CO2ML), to help in estimating the oxygenator performance, in terms of CO2 removal and oxygenator dead space (VDsML). METHODS: This study was conducted on nine pigs undergoing veno-arterial ECMO due to cardiogenic shock after induced acute myocardial infarction. The accuracy and reliability of the prototype of the volumetric capnometer (CO2RESET™, by Eurosets srl, Medolla, Italy) device was evaluated for V'CO2ML and VDsML measurements by comparing the obtained measurements from the new device to a control capnometer with the sweep gas values. Measurements were taken at five different levels of gas flow/blood flow ratio (0.5-1.5). Agreement between the corresponding measurements was taken with the two methods. We expected that 95% of differences were between d - 1.96s and d + 1.96s. RESULTS: In all, 120 coupled measurements from each device were obtained for the V'CO2ML calculation and 40 for the VDsML. The new capnometer mean percentage bias (95% confidence interval limits of agreement) was 3.86% (12.07-4.35%) for V'CO2ML and 2.62% (8.96-14.20%) for VDsML. A negative proportional bias for V'CO2ML estimation with the new device was observed with a mean of 3.86% (12.07-4.35%). No correlations were found between differences in the coupled V'CO2ML and VDsML measurements and the gas flow/blood flow ratio or temperature. Coupled measurements for V'CO2ML showed strong correlation (rs = 0.991; p = 0.0005), as did VDsML calculations (rs = 0.973; p = 0.0005). CONCLUSION: The volumetric capnometer is reliable for continuous monitoring of CO2 removal by membrane lung and VDsML calculations. Further studies are necessary to confirm these data.


Asunto(s)
Capnografía/métodos , Dióxido de Carbono/sangre , Oxigenación por Membrana Extracorpórea/métodos , Pulmón/patología , Monitoreo Fisiológico/métodos , Animales , Humanos , Porcinos
13.
Perfusion ; 33(2): 96-104, 2018 03.
Artículo en Inglés | MEDLINE | ID: mdl-28816093

RESUMEN

BACKGROUND: The use of the intra-aortic balloon pump (IABP) as a support device remains controversial due to the fact that a number of studies have shown no benefit in end mortality whilst using this device. One of the reasons for this could be the increase in vascular complications when using the pump. Therefore, the aim of the present review was to assess the current literature available with regards to IABP vascular complications during the clinical situation. METHODS: A literature search was performed, searching for IABP complications in adult human studies between 1990 and 2016. RESULTS: A total of 20 reports were identified as fitting the criteria of this study. The majority of vascular complications were limb ischemia, bleeding or mesenteric ischemia. The overall incidence of vascular complications ranged from 0.94% to 31.1%. Diabetes, peripheral vascular disease and hypertension, as well as smoking were all identified as risk factors for complications following IABP. Furthermore, studies supported the use of sheathless balloon insertion to reduce the risk of complications. CONCLUSION: Major vascular complications, including limb and mesenteric ischemia as well as bleeding and hemorrhage, have been associated with IABP. However, the incidence of these complications was generally low. Further studies are still required to truly understand the risk/benefit associated with the use of IABP.


Asunto(s)
Enfermedades Cardiovasculares/etiología , Corazón Auxiliar/efectos adversos , Hemorragia/etiología , Contrapulsador Intraaórtico/instrumentación , Enfermedades Cardiovasculares/patología , Femenino , Hemorragia/patología , Humanos , Masculino , Medición de Riesgo , Factores de Riesgo
14.
Crit Care Med ; 45(8): 1389-1397, 2017 Aug.
Artículo en Inglés | MEDLINE | ID: mdl-28538440

RESUMEN

OBJECTIVES: To assess in-hospital neurologic (CNS) complications in adult patients undergoing veno-venous extracorporeal membrane oxygenation for respiratory failure. DESIGN: Retrospective analysis of the Extracorporeal Life Support Organization's data registry. SETTING: Data reported to Extracorporeal Life Support Organization from 350 international extracorporeal membrane oxygenation centers during 1992-2015. PATIENTS: Adults (≥ 18 yr old) supported with veno-venous extracorporeal membrane oxygenation for respiratory failure. INTERVENTIONS: None. MEASUREMENTS AND MAIN RESULTS: We included 4,988 adults supported with veno-venous extracorporeal membrane oxygenation for respiratory failure. Neurologic injury was defined as brain death, seizures, stroke, and intracranial hemorrhage occurring during extracorporeal membrane oxygenation support. We used multivariable logistic regression to explore patient and extracorporeal membrane oxygenation factors associated with neurologic injury. Median age of the study cohort was 46 (interquartile range, 32-58). Four hundred twenty-six neurologic complications were reported in 356 patients (7.1%), and included 181 intracranial hemorrhage (42.5%), 100 brain deaths (23.5%), 85 stroke (19.9%), and 60 seizure events (14.1%). In-hospital mortality was significantly higher for those with CNS complications (75.8% vs 37.8%; p < 0.001) and varied by type of CNS injury; mortality was 79.6% in patients with intracranial hemorrhage, 68.2% in patients with stroke, and 50% in patients with seizures. Pre-extracorporeal membrane oxygenation cardiac arrest, continuous veno-venous hemofiltration, and hyperbilirubinemia during extracorporeal membrane oxygenation were associated with increased odds of neurologic injury. CONCLUSIONS: Approximately 7% of adults supported with veno-venous extracorporeal membrane oxygenation for respiratory failure had neurologic injury. Intracranial hemorrhage was the most frequent type, and survival for patients with neurologic injury was poor. Future investigations should evaluate anticoagulation management as well as brain/extracorporeal membrane oxygenation interaction to reduce these life-threatening events.


Asunto(s)
Encefalopatías/etiología , Oxigenación por Membrana Extracorpórea/efectos adversos , Oxigenación por Membrana Extracorpórea/métodos , Insuficiencia Respiratoria/terapia , Adulto , Encefalopatías/mortalidad , Femenino , Mortalidad Hospitalaria , Humanos , Masculino , Persona de Mediana Edad , Respiración Artificial , Estudios Retrospectivos , Factores de Tiempo
15.
Perfusion ; 32(4): 285-295, 2017 May.
Artículo en Inglés | MEDLINE | ID: mdl-27864477

RESUMEN

AIM: We evaluated the influence of intra-aortic balloon size and volume on mesenteric and renal flows. METHODS: Thirty healthy swine underwent 120-minute ligation of the left anterior descending coronary artery followed by 6 hours of reperfusion. Then, they were randomly assigned to the following five groups of animals, with six animals in each group: no intra-aortic balloon pump (IABP), a short 35-mL IABP, a short 40-mL IABP, a long 35-mL IABP and a long 40-mL IABP. Superior mesenteric artery (SMA) and renal flows were measured at baseline (t0), at 2-hour ischemia (t1) and every hour thereafter until 6 hours of reperfusion (from tR1 to tR6). RESULTS: SMA flows increased significantly at tR1 only in the two short IABP groups (p<0.001) and balloon volume did not appear to affect flows which, at any experimental time-point, were comparable using 35 mL or 40 mL balloons (p>0.05). Renal flows appeared to be influenced by balloon length, but not by volume. Indeed, flows in the renal arteries rose during IABP treatment; the increase was significantly higher in the short balloon groups and throughout the whole reperfusion (all, p<0.001). CONCLUSIONS: Changes in visceral perfusion during IABP assistance were significantly related to balloon length, but not to its volume. This could be relevant for the evolution of balloon engineering design in order to reduce the incidence of mesenteric ischemia following IABP. Further research is necessary to confirm these findings.


Asunto(s)
Contrapulsador Intraaórtico/métodos , Arteria Mesentérica Superior/fisiología , Circulación Renal/fisiología , Animales , Velocidad del Flujo Sanguíneo , Modelos Animales de Enfermedad , Distribución Aleatoria , Porcinos
16.
Crit Care Med ; 44(10): e964-72, 2016 10.
Artículo en Inglés | MEDLINE | ID: mdl-27340754

RESUMEN

OBJECTIVES: To elucidate the epidemiology, complication profiles, hospital outcome, and predisposing factors of CNS complications occurring during venoarterial extracorporeal membrane oxygenation in adults. DESIGN: Retrospective analysis of the Extracorporeal Life Support Organization registry. SETTING: Data reported to Extracorporeal Life Support Organization by 230 extracorporeal membrane oxygenation centers from 1992 to 2013. PATIENTS: Patients more than 16 years old supported with a single-run of venoarterial extracorporeal membrane oxygenation. INTERVENTIONS: None. MEASUREMENTS AND MAIN RESULTS: We examined 4,522 adult patients supported with venoarterial extracorporeal membrane oxygenation and included in the Extracorporeal Life Support Organization registry. Venoarterial extracorporeal membrane oxygenation was used for cardiac dysfunction in 3,005 patients (66.5%), cardiopulmonary resuscitation in 877 patients (19.4%), and respiratory failure in 640 patients (14.1%), respectively. Multivariate logistic regression was performed to identify factors independently associated with CNS injury. Neurologic complications occurred in 682 patients (15.1%), and included brain death in 358 patients (7.9%), cerebral infarction in 161 patients (3.6%), seizures in 83 patients (1.8%), and cerebral hemorrhage in 80 patients (1.8%). Multiple CNS complications in the same patient occurred in 70 cases. Hospital mortality in patients with CNS complications was 89%, compared with 57% in patients without (p < 0.001). In a multivariable model, age, pre-extracorporeal membrane oxygenation cardiac arrest, the use of inotropes on extracorporeal membrane oxygenation, and post-extracorporeal membrane oxygenation hypoglycemia were shown to be associated with CNS complications. CONCLUSIONS: Neurologic complications in adult patients on venoarterial extracorporeal membrane oxygenation support are common and associated with poor survival. Further research should focus on better understanding and management of brain/extracorporeal membrane oxygenation interaction to avoid such catastrophic complications.


Asunto(s)
Enfermedades del Sistema Nervioso Central/etiología , Oxigenación por Membrana Extracorpórea/efectos adversos , Adulto , Muerte Encefálica , Enfermedades del Sistema Nervioso Central/mortalidad , Trastornos Cerebrovasculares/etiología , Oxigenación por Membrana Extracorpórea/métodos , Mortalidad Hospitalaria , Humanos , Masculino , Persona de Mediana Edad , Estudios Retrospectivos , Convulsiones/etiología
17.
Europace ; 18(10): 1528-1537, 2016 Oct.
Artículo en Inglés | MEDLINE | ID: mdl-26721977

RESUMEN

AIMS: To assess the results and impact of lesion set and surgical technique on long-term success of surgical ablation during mitral surgery. METHODS AND RESULTS: The patient population consisted of 685 subjects with persistent and long-standing persistent atrial fibrillation (AF) undergoing cardiac surgery for mitral valve disease as the primary indication and concomitant ablation between January 2003 and January 2012 at three institutions. One hundred and sixty-six underwent unipolar (24.2%), 371 (54.2%) bipolar, and 148 (21.6%) had combined ablation. Median follow-up was 58.4 months (interquartile range 43.3-67.9). To appropriately account for death, a competing risk model was employed to identify predictors of cumulative incidence of recurrent AF among lesion set and surgical techniques. Eight-year freedom from recurrent arrhythmia without antiarrhythmic drugs was 0.60 ± 0.02. Success rate was higher using bipolar radiofrequency (RF) (P < 0.001), after performing mitral isthmus line (P = 0.003) and following the biatrial technique (P < 0.001). Competing risk regression revealed that use of unipolar RF [sub-hazard ratio (SHR) 2.41 (1.52-3.43), P < 0.001], combined unipolar/bipolar ablation [SHR 1.93 (0.89-2.57), P = 0.003] and the absence of right atrial ablation [SHR 2.79 (1.27-3.48), P < 0.001] were predictors of cumulative incidence of long-term recurrence. CONCLUSIONS: Our experience suggests that the use of bipolar clamp improves long-term results in surgical treatment of AF and that right-sided ablation should be routinely added. Randomized studies are necessary to confirm our findings.


Asunto(s)
Fibrilación Atrial/cirugía , Procedimientos Quirúrgicos Cardíacos/métodos , Ablación por Catéter/métodos , Enfermedades de las Válvulas Cardíacas/complicaciones , Enfermedades de las Válvulas Cardíacas/cirugía , Válvula Mitral/cirugía , Anciano , Femenino , Estudios de Seguimiento , Humanos , Italia , Masculino , Persona de Mediana Edad , Países Bajos , Complicaciones Posoperatorias/mortalidad , Recurrencia , Análisis de Regresión , Estudios Retrospectivos , Resultado del Tratamiento
18.
Heart Vessels ; 28(6): 775-84, 2013 Nov.
Artículo en Inglés | MEDLINE | ID: mdl-23180240

RESUMEN

We explored the influence of global longitudinal strain (GLS) measured with two-dimensional speckle-tracking echocardiography on left ventricular mass regression (LVMR) in patients with pure aortic stenosis (AS) and normal left ventricular function undergoing aortic valve replacement (AVR). The study population included 83 patients with severe AS (aortic valve area <1 cm(2)) treated with AVR. Bioprostheses were implanted in 58 patients (69.8 %), and the 25 remaining patients (30.2 %) received mechanical prostheses. Peak systolic longitudinal strain was measured in four-chamber (PLS4ch), two-chamber (PLS2ch), and three-chamber (PLS3ch) views, and global longitudinal strain was obtained by averaging the peak systolic values of the 18 segments. Median follow-up was 66.6 months (interquartile range 49.7-86.3 months). At follow-up, values of PLS4ch, PLS2ch, PLS3ch, and GLS were significantly lower (less negative) in patients who did not show left ventricular (LV) mass regression (all P < 0.001). Baseline global strain was the strongest predictor of lack of LVMR (odds ratio 3.5 (95 % confidence interval 3.0-4.9), P < 0.001), and GLS value ≥-9.9 % predicted lack of LVMR with 95 % sensitivity and 87 % specificity (P < 0.001). Other multivariable predictors were the preoperative LV mass value (cutoff value ≥147 g/m(2), P < 0.001), baseline effective orifice area index (cutoff ≤0.35 cm(2)/m(2), P = 0.01), and baseline mean gradient (cutoff ≥58 mmHg, P = 0.01). Finally, we failed to find interactions between GLS and other significant parameters (all P < 0.05). Global longitudinal strain accurately predicts LV mass regression in patients with pure AS undergoing AVR. Our findings must be confirmed by further larger studies.


Asunto(s)
Estenosis de la Válvula Aórtica/cirugía , Válvula Aórtica/cirugía , Implantación de Prótesis de Válvulas Cardíacas , Hipertrofia Ventricular Izquierda/etiología , Función Ventricular Izquierda , Remodelación Ventricular , Anciano , Válvula Aórtica/fisiopatología , Estenosis de la Válvula Aórtica/complicaciones , Estenosis de la Válvula Aórtica/diagnóstico , Estenosis de la Válvula Aórtica/fisiopatología , Fenómenos Biomecánicos , Bioprótesis , Ecocardiografía , Femenino , Prótesis Valvulares Cardíacas , Implantación de Prótesis de Válvulas Cardíacas/instrumentación , Humanos , Hipertrofia Ventricular Izquierda/diagnóstico , Hipertrofia Ventricular Izquierda/fisiopatología , Estimación de Kaplan-Meier , Modelos Logísticos , Masculino , Persona de Mediana Edad , Análisis Multivariante , Contracción Miocárdica , Oportunidad Relativa , Valor Predictivo de las Pruebas , Diseño de Prótesis , Estudios Retrospectivos , Factores de Riesgo , Índice de Severidad de la Enfermedad , Estrés Mecánico , Volumen Sistólico , Factores de Tiempo , Resultado del Tratamiento
19.
Chin J Cancer Res ; 25(2): 223-34, 2013 Apr.
Artículo en Inglés | MEDLINE | ID: mdl-23592904

RESUMEN

Electrochemical treatment is an alternative modality for tumor treatment based on the application of a low intensity direct electric current to the tumor tissue through two or more platinum electrodes placed within the tumor zone or in the surrounding areas. This treatment is noted for its great effectiveness, minimal invasiveness and local effect. Several studies have been conducted worldwide to evaluate the antitumoral effect of this therapy. In all these studies a variety of biochemical and physiological responses of tumors to the applied treatment have been obtained. By this reason, researchers have suggested various mechanisms to explain how direct electric current destroys tumor cells. Although, it is generally accepted this treatment induces electrolysis, electroosmosis and electroporation in tumoral tissues. However, action mechanism of this alternative modality on the tumor tissue is not well understood. Although the principle of Electrochemical treatment is simple, a standardized method is not yet available. The mechanism by which Electrochemical treatment affects tumor growth and survival may represent more complex process. The present work analyzes the latest and most important research done on the electrochemical treatment of tumors. We conclude with our point of view about the destruction mechanism features of this alternative therapy. Also, we suggest some mechanisms and strategies from the thermodynamic point of view for this therapy. In the area of Electrochemical treatment of cancer this tool has been exploited very little and much work remains to be done. Electrochemical treatment constitutes a good therapeutic option for patients that have failed the conventional oncology methods.

20.
J Thorac Cardiovasc Surg ; 165(3): 1022-1032.e2, 2023 03.
Artículo en Inglés | MEDLINE | ID: mdl-33994208

RESUMEN

OBJECTIVES: Ministernotomy and right anterior minithoracotomy are the 2 main techniques applied for minimally invasive aortic valve replacement. The goal of this study is to compare early and long-term outcomes of both techniques. METHODS: The data of 2419 patients undergoing isolated minimally invasive aortic valve replacement between 1999 and 2019 were prospectively collected. Retrospectively, patients were divided into the ministernotomy group (n = 1352) and the minithoracotomy group (n = 1067). RESULTS: After propensity score matching, 986 patients remained in each group. Operation time and rate of conversion to full sternotomy were significantly higher in the minithoracotomy group than in the ministernotomy group (184.6 ± 45.2 vs 241.3 ± 68.6, relative risk, 2.54, P = .005 and .09 vs .23, relative risk, 1.45, P = .013, respectively). The 30-day mortality, excluding cardiac death, was lower in the ministernotomy group than in the minithoracotomy group (0.012 vs 0.028, relative risk, 1.41, P = .011, respectively); the intensive care unit length of stay (12.4 vs 16.5, relative risk, 1.62, P = .037, respectively) and hospital length of stay (5.4 vs 8.7, relative risk, 1.74 P = .028, respectively) were significantly longer in the minithoracotomy group. The minithoracotomy surgical approach was the strongest independent predictor of early mortality (odds ratio, 4.24 [1.67-7.35], P = .002). The actuarial survival by Kaplan-Meier analysis at 1, 3, 5, 10, and 20 years was significantly better in the ministernotomy group than in the minithoracotomy group (P = .0001). Actuarial freedom from reoperation at 5 years was 97.3% ± 4.4% in the ministernotomy group versus 95.8% ± 5.2% in the minithoracotomy group (P = .087). CONCLUSIONS: Minimally invasive aortic valve replacement using ministernotomy is associated with reduced operative time, intensive care unit stay, hospital length of stay, and postoperative morbidities and incisional pain, and improves early and long-term mortality.


Asunto(s)
Válvula Aórtica , Implantación de Prótesis de Válvulas Cardíacas , Humanos , Válvula Aórtica/diagnóstico por imagen , Válvula Aórtica/cirugía , Implantación de Prótesis de Válvulas Cardíacas/métodos , Estudios Retrospectivos , Resultado del Tratamiento , Toracotomía/métodos , Esternotomía/métodos , Procedimientos Quirúrgicos Mínimamente Invasivos/métodos
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA