RESUMEN
Cerebrovascular events (CVEs) are a dreaded complication of transcatheter aortic valve replacement (TAVR). They are associated with significant mortality, morbidity, and reduced quality of life and impose a significant burden to health care systems. Although the rates of clinical stroke have reduced since the advent of TAVR, it remains an important complication, particularly as TAVR is increasingly utilized. CVE may occur at the time of the TAVR, as a direct consequence of the procedure, or may occur later, related to thrombosis of the prosthetic valve, atrial fibrillation, and other comorbidities. Imaging of the brain has revealed a high prevalence of subclinical cerebral infarcts (68%-98%) associated with the TAVR procedure. Although their clinical significance has not been fully established, clinically evident CVE ranges between 3% and 5% in patients considered at high operative risk to between 1% and 3% in low operative risk patients. Periprocedural CVEs are largely the result of embolization of the thrombus and tissue derived from the valve, vasculature, or myocardium. Cerebral embolic protection devices have been studied in multiple trials, with some evidence supporting a reduction in new cerebral lesion volume, number, and potentially disabling strokes. However, thus far, there is no robust evidence that they reduce the overall stroke rate. The number and severity of comorbidities, in particular, new-onset atrial fibrillation, are associated with CVEs. Valve thrombosis diagnosed using computed tomography as areas of hypoattenuated leaflet thickening has been identified in 10% to 15% of patients. This is a dynamic process associated with an increase in CVEs, but that resolves with anticoagulation or sometimes without it. Routine use of anticoagulation compared with a single antiplatelet agent is associated with an increased risk of bleeding, without any additional alleviation in risk of thromboembolism. Future studies to improve risk stratification could facilitate the tailoring of preventive therapies to patients at high risk of CVE, who stand to gain the most benefit.
RESUMEN
Aortic regurgitation (AR) is associated with morbidity and premature mortality. Surgical aortic valve replacement is not an option for many patients due to an adverse surgical risk profile, whilst transcatheter aortic valve implantation with most available prostheses has demonstrated suboptimal implantation success and outcomes. The JenaValve Trilogy™ system provides an attractive solution for such patients as it utilizes clips that directly attach onto the native valve leaflets to anchor. Initially designed for transapical delivery, the current transfemoral delivery system is under investigation in the United States and approved for aortic stenosis and regurgitation in Europe. We present an expert review on the technical aspects of the Trilogy system, provide a guide for implantation, discuss the available evidence for the technology and provide illustrative case examples.
RESUMEN
AIMS: Many cardiac pacemakers and defibrillators are not approved by regulators for magnetic resonance imaging (MRI). Even following generator exchange to an approved magnetic resonance (MR)-conditional model, many systems remain classified 'non-MR conditional' due to the leads. This classification makes patient access to MRI challenging, but there is no evidence of increased clinical risk. We compared the effect of MRI on non-MR conditional and MR-conditional pacemaker and defibrillator leads. METHODS AND RESULTS: Patients undergoing clinical 1.5T MRI with pacemakers and defibrillators in three centres over 5 years were included. Magnetic resonance imaging protocols were similar for MR-conditional and non-MR conditional systems. Devices were interrogated pre- and immediately post-scan, and at follow-up, and adverse clinical events recorded. Lead parameter changes peri-scan were stratified by MR-conditional labelling. A total of 1148 MRI examinations were performed in 970 patients (54% non-MR conditional systems, 39% defibrillators, 15% pacing-dependent) with 2268 leads. There were no lead-related adverse clinical events, and no clinically significant immediate or late lead parameter changes following MRI in either MR-conditional or non-MR conditional leads. Small reductions in atrial and right ventricular sensed amplitudes and impedances were similar between groups, with no difference in the proportion of leads with parameter changes greater than pre-defined thresholds (7.1%, 95% confidence interval: 6.1-8.3). CONCLUSIONS: There was no increased risk of MRI in patients with non-MR conditional pacemaker or defibrillator leads when following recommended protocols. Standardizing MR conditions for all leads would significantly improve access to MRI by enabling patients to be scanned in non-specialist centres, with no discernible incremental risk.
Asunto(s)
Desfibriladores Implantables , Marcapaso Artificial , Electrónica , Humanos , Imagen por Resonancia Magnética/efectos adversos , Espectroscopía de Resonancia MagnéticaRESUMEN
BACKGROUND: Permanent pacemaker (PPM) implantation is a common complication of transcatheter aortic valve implantation (TAVI). The optimum timing of PPM implantation is still unclear as conduction abnormalities evolve and a balance needs to be struck between conservative delays in the hope of conduction recovery and overutilization of pacing. This study aimed to assess the safety and efficacy of early PPM implantation, without an observation period, among TAVI patients. METHODS: This is a retrospective, observational study of 1398 TAVI patients. Clinical and pacing data were collected at baseline, 30 days and at a median of 15 (4-21) months post-TAVI. Study endpoints included PPM-related complications, pacing utilization and hospital length of stay. RESULTS: One hundred five patients (8.2%) required a PPM, of which 13 were implanted pre and 92 post-TAVI. Seventy-six percent required pacing for either second- or third-degree heart block. Time to implantation for post-TAVI PPM was 1 (0-3) day. Six patients experienced a pacing-related complication- lead displacement (n = 3), hematoma (n = 2), and device infection (n = 1). Pacing utilization defined as pacing >10% of the time or a pacing requirement at the time of the pacing check was demonstrated in 83% of patients. Multivariate analysis revealed complete heart block (CHB) was the only independent predictor of pacing utilization. Hospital length of stay for the post-TAVI PPM group was longer than the group without PPM (4 [2-8] vs. 3 [2-4] days; p < .001). CONCLUSIONS: Early PPM implantation in TAVI patients is safe and majority of patients require pacing in the short and mid-term.
Asunto(s)
Estimulación Cardíaca Artificial , Marcapaso Artificial , Complicaciones Posoperatorias/prevención & control , Reemplazo de la Válvula Aórtica Transcatéter , Anciano , Anciano de 80 o más Años , Femenino , Humanos , Tiempo de Internación/estadística & datos numéricos , Masculino , Estudios RetrospectivosRESUMEN
AIMS: Cardiac amyloidosis is common in elderly patients with aortic stenosis (AS) referred for transcatheter aortic valve implantation (TAVI). We hypothesized that patients with dual aortic stenosis and cardiac amyloid pathology (AS-amyloid) would have different baseline characteristics, periprocedural and mortality outcomes. METHODS AND RESULTS: Patients aged ≥75 with severe AS referred for TAVI at two sites underwent blinded bone scintigraphy prior to intervention (Perugini Grade 0 negative, 1-3 increasingly positive). Baseline assessment included echocardiography, electrocardiogram (ECG), blood tests, 6-min walk test, and health questionnaire, with periprocedural complications and mortality follow-up. Two hundred patients were recruited (aged 85 ± 5 years, 50% male). AS-amyloid was found in 26 (13%): 8 Grade 1, 18 Grade 2. AS-amyloid patients were older (88 ± 5 vs. 85 ± 5 years, P = 0.001), with reduced quality of life (EQ-5D-5L 50 vs. 65, P = 0.04). Left ventricular wall thickness was higher (14 mm vs. 13 mm, P = 0.02), ECG voltages lower (Sokolow-Lyon 1.9 ± 0.7 vs. 2.5 ± 0.9 mV, P = 0.03) with lower voltage/mass ratio (0.017 vs. 0.025 mV/g/m2, P = 0.03). High-sensitivity troponin T and N-terminal pro-brain natriuretic peptide were higher (41 vs. 21 ng/L, P < 0.001; 3702 vs. 1254 ng/L, P = 0.001). Gender, comorbidities, 6-min walk distance, AS severity, prevalence of disproportionate hypertrophy, and post-TAVI complication rates (38% vs. 35%, P = 0.82) were the same. At a median follow-up of 19 (10-27) months, there was no mortality difference (P = 0.71). Transcatheter aortic valve implantation significantly improved outcome in the overall population (P < 0.001) and in those with AS-amyloid (P = 0.03). CONCLUSIONS: AS-amyloid is common and differs from lone AS. Transcatheter aortic valve implantation significantly improved outcome in AS-amyloid, while periprocedural complications and mortality were similar to lone AS, suggesting that TAVI should not be denied to patients with AS-amyloid.
Asunto(s)
Amiloidosis , Estenosis de la Válvula Aórtica , Implantación de Prótesis de Válvulas Cardíacas , Reemplazo de la Válvula Aórtica Transcatéter , Anciano , Anciano de 80 o más Años , Válvula Aórtica/cirugía , Estenosis de la Válvula Aórtica/cirugía , Femenino , Humanos , Masculino , Prevalencia , Calidad de Vida , Factores de Riesgo , Tomografía Computarizada por Rayos X , Reemplazo de la Válvula Aórtica Transcatéter/efectos adversos , Resultado del TratamientoRESUMEN
Aortic regurgitation (AR) is a common clinical disease associated with significant morbidity and mortality. Investigations based largely on non-invasive imaging are pivotal in discerning the severity of disease and its impact on the heart. Advances in technology have contributed to improved risk stratification and to our understanding of the pathophysiology of AR. Surgical aortic valve replacement is the predominant treatment. However, its use is limited to patients with an acceptable surgical risk profile. Transcatheter aortic valve implantation is an alternative treatment. However, this therapy remains in its infancy, and further data and experience are required. This review article on AR describes its prevalence, mechanisms, diagnosis and treatment.
Asunto(s)
Insuficiencia de la Válvula Aórtica , Válvula Aórtica , Implantación de Prótesis de Válvulas Cardíacas , Reemplazo de la Válvula Aórtica Transcatéter , Humanos , Insuficiencia de la Válvula Aórtica/fisiopatología , Insuficiencia de la Válvula Aórtica/terapia , Insuficiencia de la Válvula Aórtica/cirugía , Reemplazo de la Válvula Aórtica Transcatéter/efectos adversos , Implantación de Prótesis de Válvulas Cardíacas/métodos , Implantación de Prótesis de Válvulas Cardíacas/efectos adversos , Implantación de Prótesis de Válvulas Cardíacas/instrumentación , Válvula Aórtica/cirugía , Válvula Aórtica/fisiopatología , Válvula Aórtica/diagnóstico por imagen , Resultado del Tratamiento , Prótesis Valvulares CardíacasRESUMEN
AIMS: Surgical ablation of atrial fibrillation (AF) has been demonstrated to be a safe procedure conducted concomitantly alongside cardiac surgery. However, there are conflicting guideline recommendations surrounding indications for surgical ablation. We conducted a systematic review of current recommendations on concomitant surgical AF ablation. METHODS AND RESULTS: We identified publications from MEDLINE and EMBASE between January 2011 and December 2022 and additionally searched Guideline libraries and websites of relevant organizations in accordance with Preferred Reporting Items for Systematic Reviews and Meta-Analyses guidelines. Of 895 studies screened, 4 were rigorously developed (AGREE-II > 50%) and included. All guidelines agreed on the definitions of paroxysmal, persistent, and longstanding AF based on duration and refraction to current treatment modalities. In the Australia-New Zealand (CSANZ) and European (EACTS) guidelines, opportunistic screening for patients >65 years is recommended. The EACTS recommends systematic screening for those aged >75 or at high stroke risk (Class IIa, Level B). However, this was not recommended by American Heart Association or Society of Thoracic Surgeons guidelines. All guidelines identified surgical AF ablation during concomitant cardiac surgery as safe and recommended for consideration by a Heart Team with notable variation in recommendation strength and the specific indication (three guidelines fail to specify any indication for surgery). Only the STS recommended left atrial appendage occlusion (LAAO) alongside surgical ablation (Class IIa, Level C). CONCLUSION: Disagreements exist in recommendations for specific indications for concomitant AF ablation and LAAO, with the decision subject to Heart Team assessment. Further evidence is needed to develop recommendations for specific indications for concomitant AF procedures and guidelines need to be made congruent.
Asunto(s)
Fibrilación Atrial , Procedimientos Quirúrgicos Cardíacos , Accidente Cerebrovascular , Cirugía Torácica , Estados Unidos , Humanos , Fibrilación Atrial/complicaciones , Fibrilación Atrial/cirugía , Accidente Cerebrovascular/etiología , Accidente Cerebrovascular/prevención & control , AustraliaRESUMEN
In the Targeted therapy with a localised abluminal coated, low-dose sirolimus-eluting, biodegreadable polymer coronary stent (TARGET; NCT02520180) All Comers trial the biodegradable polymer (BP) sirolimus-eluting FIREHAWK stent was noninferior to the durable polymer (DP) everolimus-eluting XIENCE stent with respect to target lesion failure (TLF) at 1 and 5 years; however, the long-term safety and efficacy in the setting of acute coronary syndromes (ACS) are not known. We sought to assess the long-term outcomes in ACS versus chronic coronary syndromes (CCS) with BP sirolimus-eluting stent (SES) versus DP everolimus-eluting stent (EES). The TARGET AC study was a multicenter, open-label, noninferiority trial of all comer patients randomly allocated 1:1 to BP SES or DP EES (stratified by ST-elevation myocardial infarction and study site). In this predefined substudy, the outcomes were compared based on clinical presentation (ACS vs CCS) and treatment allocation. A total of 1,653 patients were enrolled (728 with ACS and 922 with CCS), with 94% completing the 5-year follow-up. The baseline characteristics were well-matched between the 2 stent types; however, co-morbidities were more prevalent in the CCS than in the ACS population. TLF (15.5% vs 17.7%, p = 0.24), patient-oriented outcomes (32.0% vs 34.4%, p = 0.31), and stent thrombosis (4.1% vs 3.3%, p = 0.40) were similar between patients with ACS and patients with CCS. In the ACS cohort, the outcomes at 5 years for BP SES versus DP EES were similar for TLF (16.0% vs 14.9%, p = 0.70), ischemia-driven target lesion revascularization (5.6% vs 8.3%, p = 0.17), and definite/probable stent thrombosis (2.7% vs 4.6%, p = 0.18). The same was true for the CCS cohort, with 5-year outcomes for BP SES versus DP EES for TLF (18.0% vs 17.4%, p = 0.82), ischemia-driven target lesion revascularization (6.4% vs 5.0%, p = 0.37), and definite/probable stent thrombosis (3.0% vs 1.8%, p = 0.26). In conclusion, in the TARGET AC trial, 1 in 3 patients had a major adverse event at 5 years, irrespective of CCS or ACS presentation. Long-term, the BP sirolimus-eluting FIREHAWK stent was as safe and effective as the DP everolimus-eluting XIENCE stent across the spectrum of clinical presentations.
Asunto(s)
Síndrome Coronario Agudo , Enfermedad de la Arteria Coronaria , Stents Liberadores de Fármacos , Intervención Coronaria Percutánea , Infarto del Miocardio con Elevación del ST , Trombosis , Humanos , Implantes Absorbibles , Síndrome Coronario Agudo/cirugía , Enfermedad de la Arteria Coronaria/terapia , Everolimus/farmacología , Intervención Coronaria Percutánea/efectos adversos , Polímeros , Diseño de Prótesis , Factores de Riesgo , Sirolimus/farmacología , Sirolimus/uso terapéutico , Infarto del Miocardio con Elevación del ST/etiología , Trombosis/etiología , Resultado del TratamientoRESUMEN
OBJECTIVES: Grading the severity of moderate mixed aortic stenosis and regurgitation (MAVD) is challenging and the disease poorly understood. Identifying markers of haemodynamic severity will improve risk stratification and potentially guide timely treatment. This study aims to identify prognostic haemodynamic markers in patients with moderate MAVD. METHODS: Moderate MAVD was defined as coexisting moderate aortic stenosis (aortic valve area (AVA) 1.0-1.5 cm2) and moderate aortic regurgitation (vena contracta (VC) 0.3-0.6 cm). Consecutive patients diagnosed between 2015 and 2019 were included from a multicentre registry. The primary composite outcome of death or heart failure hospitalisation was evaluated among these patients. Demographics, comorbidities, echocardiography and treatment data were assessed for their prognostic significance. RESULTS: 207 patients with moderate MAVD were included, aged 78 (66-84) years, 56% male sex, AVA 1.2 (1.1-1.4) cm2 and VC 0.4 (0.4-0.5) cm. Over a follow-up of 3.5 (2.5-4.7) years, the composite outcome was met in 89 patients (43%). Univariable associations with the primary outcome included older age, previous myocardial infarction, previous cerebrovascular event, atrial fibrillation, New York Heart Association >2, worse renal function, tricuspid regurgitation ≥2 and mitral regurgitation ≥2. Markers of biventricular systolic function, cardiac remodelling and transaortic valve haemodynamics demonstrated an inverse association with the primary composite outcome. In multivariable analysis, peak aortic jet velocity (Vmax) was independently and inversely associated with the composite outcome (HR: 0.63, 95% CI 0.43 to 0.93; p=0.021) in an adjusted model along with age (HR: 1.05, 95% CI 1.03 to 1.08; p<0.001), creatinine (HR: 1.002, 95% CI 1.001 to 1.003; p=0.005), previous cerebrovascular event (85% vs 42%; HR: 3.04, 95% CI 1.54 to 5.99; p=0.001) and left ventricular ejection fraction (LVEF) (HR: 0.97, 95% CI 0.95 to 0.99; p=0.007). Patients with Vmax ≤2.8 m/s and LVEF ≤50% (n=27) had the worst outcome compared with the rest of the population (72% vs 41%; HR: 3.87, 95% CI 2.20 to 6.80; p<0.001). CONCLUSIONS: Patients with truly moderate MAVD have a high incidence of death and heart failure hospitalisation (43% at 3.5 (2.5-4.7) years). Within this group, a high-risk group characterised by disproportionately low aortic Vmax (≤2.8 m/s) and adverse remodelling (LVEF ≤50%) have the worst outcomes.
Asunto(s)
Insuficiencia de la Válvula Aórtica , Estenosis de la Válvula Aórtica , Índice de Severidad de la Enfermedad , Anciano , Anciano de 80 o más Años , Femenino , Humanos , Masculino , Válvula Aórtica/diagnóstico por imagen , Válvula Aórtica/fisiopatología , Insuficiencia de la Válvula Aórtica/fisiopatología , Insuficiencia de la Válvula Aórtica/mortalidad , Insuficiencia de la Válvula Aórtica/diagnóstico , Estenosis de la Válvula Aórtica/fisiopatología , Estenosis de la Válvula Aórtica/complicaciones , Estenosis de la Válvula Aórtica/mortalidad , Estenosis de la Válvula Aórtica/diagnóstico , Estenosis de la Válvula Aórtica/diagnóstico por imagen , Ecocardiografía , Insuficiencia Cardíaca/fisiopatología , Insuficiencia Cardíaca/mortalidad , Hemodinámica , Pronóstico , Sistema de Registros , Estudios Retrospectivos , Medición de Riesgo/métodos , Factores de RiesgoRESUMEN
BACKGROUND: Extracellular volume fraction (ECV) is a marker for myocardial fibrosis and infiltration, can be quantified using cardiac computed tomography (ECVCT), and has prognostic utility in several diseases. This study aims to map out regional differences in ECVCT to obtain greater insights into the pathophysiological mechanisms of ECV expansion and its clinical implications. METHODS: Three prospective cohorts were included: patients with aortic stenosis (AS) and coexisting AS and transthyretin cardiac amyloidosis were referred for a transcatheter aortic valve replacement and had ECG-gated CT angiography and Technetium-99m-labelled 3,3-diphosphono-1,2-propanodicarboxylic acid scintigraphy to differentiate between the 2 cohorts. Controls had CT angiography and cardiac magnetic resonance demonstrating no significant coronary artery disease or infarction. Global and regional ECVCT was analyzed, and its association with mortality was assessed for patients with AS. RESULTS: In 199 patients, controls (n=65; 66% male), AS (n=115), and coexisting AS and transthyretin cardiac amyloidosis (n=19) had a global ECVCT of 26.1 (25.0-27.8%) versus 29.1 (27.5-31.1%) versus 37.4 (32.5-46.6%), respectively; P<0.001. Across cohorts, ECVCT was higher at the base (versus apex), the inferoseptum (versus anterolateral wall), and the subendocardium (versus subepicardium); P<0.05 for all. Among patients with AS, epicardial ECVCT, rather than any other regional value or global ECVCT, was the strongest predictor of mortality at a median of 3.9 (max 6.3) years (adjusted hazard ratio, 1.21 [95% CI, 1.08-1.36]; P=0.002). CONCLUSIONS: Regional differences in ECVCT suggest a predilection for fibrosis and amyloid infiltration at the base, subendocardium, inferior wall, and septum more than the anterior and lateral myocardium. ECVCT can predict long-term mortality with the subepicardium demonstrating the strongest discriminatory power. REGISTRATION: URL: https://www.clinicaltrials.gov; Unique identifiers: NCT03029026 and NCT03094143.
Asunto(s)
Neuropatías Amiloides Familiares , Estenosis de la Válvula Aórtica , Angiografía por Tomografía Computarizada , Fibrosis , Miocardio , Humanos , Estenosis de la Válvula Aórtica/diagnóstico por imagen , Estenosis de la Válvula Aórtica/fisiopatología , Estenosis de la Válvula Aórtica/complicaciones , Estenosis de la Válvula Aórtica/mortalidad , Masculino , Femenino , Anciano , Estudios Prospectivos , Angiografía por Tomografía Computarizada/métodos , Anciano de 80 o más Años , Miocardio/patología , Neuropatías Amiloides Familiares/diagnóstico por imagen , Neuropatías Amiloides Familiares/complicaciones , Neuropatías Amiloides Familiares/mortalidad , Valor Predictivo de las Pruebas , Pronóstico , Angiografía Coronaria/métodos , Reemplazo de la Válvula Aórtica Transcatéter , Válvula Aórtica/diagnóstico por imagen , Válvula Aórtica/patología , Cardiomiopatías/diagnóstico por imagen , Cardiomiopatías/fisiopatología , Persona de Mediana EdadRESUMEN
BACKGROUND: Severe pure aortic regurgitation (AR) carries a high mortality and morbidity risk, and it is often undertreated because of the inherent surgical risk. Transcatheter heart valves (THVs) have been used off-label in this setting with overall suboptimal results. The dedicated "purpose-built" Jena Valve Trilogy (JVT, JenaValve Technology) showed an encouraging performance, although it has never been compared to other THVs. OBJECTIVES: The aim of our study was to assess the performance of the latest iteration of THVs used off-label in comparison to the purpose-built JVT in inoperable patients with severe AR. METHODS: We performed a multicenter, retrospective registry with 18 participating centers worldwide collecting data on inoperable patients with severe AR of the native valve. A bicuspid aortic valve was the main exclusion criterion. The primary endpoints were technical and device success, 1-year all-cause mortality, and the composite of 1-year mortality and the heart failure rehospitalization rate. RESULTS: Overall, 256 patients were enrolled. THVs used off-label were used in 168 cases (66%), whereas JVT was used in 88 (34%). JVT had higher technical (81% vs 98%; P < 0.001) and device success rates (73% vs 95%; P < 0.001), primarily driven by significantly lower incidences of THV embolization (15% vs 1.1%; P < 0.001), the need for a second valve (11% vs 1.1%; P = 0.004), and moderate residual AR (10% vs 1.1%; P = 0.007). The permanent pacemaker implantation rate was comparable and elevated for both groups (22% vs 24%; P = 0.70). Finally, no significant difference was observed at the 1-year follow-up in terms of mortality (HR: 0.99; P = 0.980) and the composite endpoint (HR: 1.5; P = 0.355). CONCLUSIONS: The JVT platform has a better acute performance than other THVs when used off-label for inoperable patients with severe AR. A longer follow-up is conceivably needed to detect a possible impact on prognosis.
Asunto(s)
Insuficiencia de la Válvula Aórtica , Válvula Aórtica , Prótesis Valvulares Cardíacas , Diseño de Prótesis , Sistema de Registros , Índice de Severidad de la Enfermedad , Reemplazo de la Válvula Aórtica Transcatéter , Humanos , Insuficiencia de la Válvula Aórtica/fisiopatología , Insuficiencia de la Válvula Aórtica/mortalidad , Insuficiencia de la Válvula Aórtica/diagnóstico por imagen , Insuficiencia de la Válvula Aórtica/etiología , Femenino , Masculino , Estudios Retrospectivos , Anciano , Resultado del Tratamiento , Anciano de 80 o más Años , Factores de Riesgo , Válvula Aórtica/cirugía , Válvula Aórtica/fisiopatología , Válvula Aórtica/diagnóstico por imagen , Factores de Tiempo , Reemplazo de la Válvula Aórtica Transcatéter/efectos adversos , Reemplazo de la Válvula Aórtica Transcatéter/mortalidad , Reemplazo de la Válvula Aórtica Transcatéter/instrumentación , Readmisión del Paciente , Recuperación de la Función , Europa (Continente) , Insuficiencia Cardíaca/mortalidad , Insuficiencia Cardíaca/terapia , Insuficiencia Cardíaca/fisiopatología , Insuficiencia Cardíaca/diagnóstico , HemodinámicaRESUMEN
A 54-year-old woman who had recently undergone surgical mitral and tricuspid valve repair was diagnosed with severe aortic regurgitation. She was scheduled for percutaneous treatment and underwent successful transcatheter aortic valve implantation with a 27-mm Trilogy valve (JenaValve Technology). The case documents feasibility of percutaneous treatment in the presence of a mitral ring.
RESUMEN
Acute decompensated aortic stenosis (ADAS) is common. The cumulative burden of ADAS from a clinical, health care resource, and financial perspective is unknown. This study sought to assess the national impact of ADAS compared with electively treated, stable patients with aortic stenosis (non-ADAS). Using the National Readmissions Database between 2016 and 2019, patients with ADAS and non-ADAS were identified using International Classification of Diseases, Tenth Revision codes. Patients with ADAS were propensity-matched to non-ADAS patients (1:2) using age, gender, and Charlson co-morbidity index. We compared in-hospital mortality, length of stay (LOS), health care-associated costs, and 90-day readmission data between the 2 cohorts. A total of 51,498 propensity-matched patients were included in this study: median age 75 years, 64% men. The in-hospital mortality for ADAS was higher than non-ADAS (2.8% vs 1.5%, p <0.0001). The LOS during the index admission was longer for ADAS (9 [5 to 13] vs 4 [2 to 6] days, p <0.0001). The health care-associated costs per patient was greater for ADAS ($55,450.0 [41,860.4 to 74,500.7] vs $43,405.7 [34,218.5 to 56,034.8], p <0.0001). Readmission to hospital within 90 days was more frequent in ADAS (21.1 vs 16.8%, p <0.001). The in-hospital mortality during readmission was higher with ADAS (3.9% vs 2.8%, p = 0.004). The readmission LOS was longer with ADAS (4 [2 to 7] vs 3 [2 to 6] days, p <0.0001). In conclusion, ADAS imposes a significant burden clinically and financially and on health care resources compared with non-ADAS during the index admission and 90-day follow-up. There is an urgent need to predict ADAS and optimize the timing of aortic valve replacement to reduce the incidence and the burden associated with ADAS.
Asunto(s)
Estenosis de la Válvula Aórtica , Reemplazo de la Válvula Aórtica Transcatéter , Masculino , Humanos , Anciano , Femenino , Readmisión del Paciente , Reemplazo de la Válvula Aórtica Transcatéter/efectos adversos , Factores de Riesgo , Complicaciones Posoperatorias/epidemiología , Estenosis de la Válvula Aórtica/epidemiología , Estenosis de la Válvula Aórtica/cirugía , Estenosis de la Válvula Aórtica/complicaciones , Válvula Aórtica/cirugía , Costos de la Atención en Salud , Resultado del TratamientoRESUMEN
Patients with classic low-flow low-gradient (cLFLG) aortic stenosis (AS) have a poor prognosis but still benefit from aortic valve replacement. There is a paucity of evidence to guide the choice between transcatheter aortic valve replacement (TAVR) and surgical aortic valve replacement (SAVR). This study compared procedural and midterm outcomes in patients with cLFLG AS between TAVR and SAVR. Patients with cLFLG AS, defined as an aortic valve area ≤1 cm2, mean gradient <40 mm Hg, and left ventricular ejection fraction <50%, were selected from a single center between 2015 and 2020. Inverse probability weighting and regression were used to adjust for differences in baseline characteristics, the nonrandom assignment of treatment modalities, and procedural differences. The primary end point was all-cause mortality. A total of 322 patients (220 TAVR and 102 SAVR) were included. At a follow-up of 4.4 ± 1.5 years, the adjusted hazard ratio (HR) for mortality after inverse probability weighting with SAVR was 0.66, 95% confidence interval (CI) 0.31 to 1.35; p = 0.24. Worse renal function at baseline (per 10 ml/min/m2 increase HR 0.92, 95% CI 0.84 to 1.00, p = 0.04) and multiple valve interventions (HR 5.39, 95% CI 2.62 to 11.12, p <0.001) independently predicted mortality. There was no difference in stroke and permanent pacemaker implantation, but the rates of renal replacement therapy were higher among the SAVR cohort: 13.7% versus 0%; p <0.001. In conclusion, among patients with cLFLG AS, there was no difference in midterm mortality between TAVR and SAVR, supporting the use of either treatment. However, in patients with poor renal function or at risk of renal failure, TAVR may be the preferred option.
Asunto(s)
Estenosis de la Válvula Aórtica , Implantación de Prótesis de Válvulas Cardíacas , Reemplazo de la Válvula Aórtica Transcatéter , Humanos , Reemplazo de la Válvula Aórtica Transcatéter/efectos adversos , Implantación de Prótesis de Válvulas Cardíacas/efectos adversos , Volumen Sistólico , Resultado del Tratamiento , Función Ventricular Izquierda , Factores de Riesgo , Estenosis de la Válvula Aórtica/cirugía , Válvula Aórtica/cirugíaRESUMEN
AIMS: Aortic stenosis is characterized by fibrosis and calcification of the valve, with a higher proportion of fibrosis observed in women. Stenotic bicuspid aortic valves progress more rapidly than tricuspid valves, which may also influence the relative composition of the valve. We aimed to investigate the influence of cusp morphology on quantitative aortic valve composition quantified from contrast-enhanced computed tomography angiography in severe aortic stenosis. METHODS AND RESULTS: Patients undergoing transcatheter aortic valve implantation with bicuspid and tricuspid valves were propensity matched 1:1 by age, sex, and comorbidities. Computed tomography angiograms were analysed using semi-automated software to quantify the fibrotic and calcific scores (volume/valve annular area) and the fibro-calcific ratio (fibrotic score/calcific score). The study population (n = 140) was elderly (76 ± 10 years, 62% male) and had a peak aortic jet velocity of 4.1 ± 0.7 m/s. Compared with those with tricuspid valves (n = 70), patients with bicuspid valves (n = 70) had higher fibrotic scores [204 (interquartile range 118-267) vs. 144 (99-208) mm3/cm2, P = 0.006] with similar calcific scores (P = 0.614). Women had greater fibrotic scores than men in bicuspid [224 (181-307) vs. 169 (109-247) mm3/cm2, P = 0.042] but not tricuspid valves (P = 0.232). Men had greater calcific scores than women in both bicuspid [203 (124-355) vs. 130 (70-182) mm3/cm2, P = 0.008] and tricuspid [177 (136-249) vs. 100 (62-150) mm3/cm2, P = 0.004] valves. Among both valve types, women had a greater fibro-calcific ratio compared with men [tricuspid 1.86 (0.94-2.56) vs. 0.86 (0.54-1.24), P = 0.001 and bicuspid 1.78 (1.21-2.90) vs. 0.74 (0.44-1.53), P = 0.001]. CONCLUSIONS: In severe aortic stenosis, bicuspid valves have proportionately more fibrosis than tricuspid valves, especially in women.
Asunto(s)
Estenosis de la Válvula Aórtica , Enfermedad de la Válvula Aórtica Bicúspide , Reemplazo de la Válvula Aórtica Transcatéter , Humanos , Masculino , Femenino , Anciano , Válvula Aórtica/diagnóstico por imagen , Válvula Aórtica/cirugía , Válvula Aórtica/patología , Estenosis de la Válvula Aórtica/diagnóstico por imagen , Estenosis de la Válvula Aórtica/cirugía , Estenosis de la Válvula Aórtica/patología , Enfermedad de la Válvula Aórtica Bicúspide/patología , FibrosisRESUMEN
BACKGROUND: Acute decompensated aortic stenosis (ADAS) is common and associated with higher mortality, acute kidney injury (AKI) and longer hospital length of stay (LoS) compared with electively treated stable AS. The aim of this study was to assess the impact of a dedicated pathway that reduces time to transcatheter aortic valve implantation (TAVI) in ADAS, hypothesizing that LoS can be reduced without compromising patient safety. METHODS AND RESULTS: Using a prospective, open label, cluster design, patients from 5 referring centres were allocated to the ASessment and TReatment In Decompensated Aortic Stenosis (ASTRID-AS) pathway where the diagnosis, referral, investigations and treatment of ADAS were prioritised and expedited. 15 hospitals remained on the conventional pathway that followed the same process, albeit according to a waiting list. The primary efficacy endpoint was hospital LoS and the secondary safety endpoint, a composite of death or AKI at 30 days post-TAVI. 58 conventional patients and 25 ASTRID-AS patients were included in this study. Time to TAVI in the conventional vs. ASTRID-AS cohort was 22 (15-30) vs. 10 (6-12) days; P < 0.001, respectively. Length of hospital stay was 24 (18-33) vs. 13 (8-18) days; P < 0.001, respectively. 13.4 bed days were saved per patient using the ASTRID-AS pathway. Secondary safety endpoint occurred in 12 (20.7%) vs. 1 (4.0%) patients; P = 0.093, respectively. Procedural complications were similar between the two cohorts. CONCLUSION: A dedicated pathway for ADAS that shortens time to TAVI demonstrated reduced hospital LoS without compromising patient safety and a trend towards improving clinical outcomes.
Asunto(s)
Lesión Renal Aguda , Estenosis de la Válvula Aórtica , Humanos , Proyectos Piloto , Estudios Prospectivos , Resultado del Tratamiento , Estenosis de la Válvula Aórtica/diagnósticoRESUMEN
Aortic stenosis (AS) is a progressive disease that carries a poor prognosis. Patients are managed conservatively until satisfying an indication for transcatheter aortic valve implantation (TAVI) or surgical aortic valve replacement (SAVR) based on AS severity and the presence of symptoms or adverse impact on the myocardium. Up to 1 in 3 TAVIs are performed for patients with acute symptoms of dyspnea at rest, angina, and/or syncope - termed acute decompensated aortic stenosis (ADAS) and require urgent aortic valve replacement. These patients have longer hospital length of stay, undergo physical deconditioning, and have a higher rate of acute kidney injury and mortality compared to stable patients with less severe symptoms. There is an urgent need to prevent ADAS and to deliver pathways to manage and improve ADAS-related outcomes. We provide here a contemporary review on epidemiological and pathophysiological aspects of ADAS, with a focus on the impact of ADAS from clinical and economic perspectives. We offer a global overview of the available evidence for treatment of ADAS and with priorities suggested for addressing current gaps in the literature and unmet clinical needs to improve outcomes for AS patients.
Asunto(s)
Estenosis de la Válvula Aórtica , Implantación de Prótesis de Válvulas Cardíacas , Reemplazo de la Válvula Aórtica Transcatéter , Humanos , Factores de Riesgo , Resultado del Tratamiento , Estenosis de la Válvula Aórtica/diagnóstico , Estenosis de la Válvula Aórtica/cirugía , Reemplazo de la Válvula Aórtica Transcatéter/efectos adversos , Válvula Aórtica/cirugíaRESUMEN
BACKGROUND: Transcatheter aortic valve replacement (TAVR) in patients with pure severe native aortic valve regurgitation (NAVR) has been associated with suboptimal results. The available evidence concerns mostly outdated transcatheter heart valves (THVs). OBJECTIVES: The aim of this study was to investigate the performance of new-generation THVs in patients treated for pure severe NAVR. METHODS: The PANTHEON (Performance of Currently Available Transcatheter Aortic Valve Platforms in Inoperable Patients With Pure Aortic Regurgitation of a Native Valve) study retrospectively included patients who underwent TAVR with currently available devices (both self-expanding [SE] and balloon expandable [BE]) for severe NAVR. Technical and device success rates as well as a composite of all-cause mortality and heart failure rehospitalization at 1 year were evaluated. The rate and clinical consequences of acute transcatheter valve embolization or migration (TVEM) were also considered. RESULTS: A total of 201 patients were included. Overall technical and device success rates were 83.6% and 76.1%, respectively, and did not differ between SE and BE devices. These figures were due mostly to TVEM occurrence (14.6% vs 16.1%; P = 0.47) and residual moderate or greater aortic regurgitation (9.2% vs 10.1%; P = 0.87). Patients who experienced TVEM compared with those without TVEM had a significantly higher incidence of the composite endpoint at 1 year (25.7% vs 15.8%; P = 0.05). CONCLUSIONS: Despite improved THV platforms and techniques, TAVR for pure severe NAVR remains a challenging procedure, with significant risk for TVEM. SE and BE platforms demonstrated comparable performance in this setting. (Performance of Currently Available Transcatheter Aortic Valve Platforms in Inoperable Patients With Pure Aortic Regurgitation of a Native Valve [PANTHEON]; NCT05319171).
Asunto(s)
Insuficiencia de la Válvula Aórtica , Reemplazo de la Válvula Aórtica Transcatéter , Humanos , Reemplazo de la Válvula Aórtica Transcatéter/efectos adversos , Insuficiencia de la Válvula Aórtica/diagnóstico por imagen , Insuficiencia de la Válvula Aórtica/etiología , Insuficiencia de la Válvula Aórtica/cirugía , Válvula Aórtica/diagnóstico por imagen , Válvula Aórtica/cirugía , Estudios Retrospectivos , Resultado del TratamientoRESUMEN
Although transcatheter aortic valve implantation (TAVI) has revolutionised the landscape of treatment for aortic stenosis, there exists a cohort of patients where TAVI is deemed futile. Among the pivotal high-risk trials, one-third to half of patients either died or received no symptomatic benefit from the procedure at 1 year. Futility of TAVI results in the unnecessary exposure of risk for patients and inefficient resource utilisation for healthcare services. Several cardiac and extra-cardiac conditions and frailty increase the risk of mortality despite TAVI. Among the survivors, these comorbidities can inhibit improvements in symptoms and quality of life. However, certain conditions are reversible with TAVI (e.g. functional mitral regurgitation), attenuating the risk and improving outcomes. Quantification of disease severity, identification of reversible factors and a systematic evaluation of frailty can substantially improve risk stratification and outcomes. This review examines the contribution of pre-existing comorbidities towards futility in TAVI and suggests a systematic approach to guide patient evaluation.