1.
Arthroscopy ; 36(11): 2805-2811, 2020 11.
Artículo en Inglés | MEDLINE | ID: mdl-32554073

RESUMEN

PURPOSE: The purpose of this study was to evaluate the cyclic displacement, stiffness, and ultimate load to failure of 3 all-suture anchors in human cadaveric greater tuberosities. METHODS: Three all-suture anchors indicated for rotator cuff repair were tested in 14 matched pairs of human cadaver fresh-frozen humeri. Anchors were inserted at 3 locations from anterior to posterior along the greater tuberosity and placed 5 mm from the articular margin. The constructs were cycled from 10 to 60 N at 1 Hz for 200 cycles. The anchors that survived cycling were then subjected to a single pull to failure test. A Kruskal-Wallis 1-way analysis of variance on ranks was performed to compare the displacement, stiffness, and ultimate load to failure of the different anchors tested. RESULTS: One matched pair was excluded because of poor bone quality; therefore, 13 matched pairs were included in the study. After 20, 100, and 200 cycles, there was no difference in median displacement between the anchors tested (P = .23, P = .21, P = .18, respectively). The median ultimate load-to-failure between the Iconix (295.2 N, 95% confidence interval [CI], 125-762.2), JuggerKnot (287.6 N, 95% CI, 152.9-584.4), and Q-fix (333.3 N, 95% CI, 165.0-671.9) showed no statistically significant difference (P = .58). After 20, 100, and 200 cycles, there was no difference in median stiffness between the anchors tested (P = .41, P = .19, P = .26 respectively). Displacement greater than 5 mm occurred in 0 Iconix anchors (0%), 1 JuggerKnot anchor (3.64%), and 2 Q-fix anchors (7.69%). One JuggerKnot anchor failed by anchor pullout during cyclic loading. CONCLUSIONS: When tested in human cadaveric humeral greater tuberosities 3 all-suture anchors, the 2.9-mm JuggerKnot, the 2.8-mm Q-fix, and the 2.3-mm Iconix, showed no significant differences in median displacement or stiffness after 20, 100, or 200 cycles or in median ultimate load to failure. Although not statistically significant, the Iconix was the only anchor tested to have no failures, whereas the JuggerKnot had both a clinical and catastrophic failure and the Q-fix had 2 clinical failures. LEVEL OF EVIDENCE: Level V, Controlled Laboratory Study.


Asunto(s)
Hombro/cirugía , Anclas para Sutura , Técnicas de Sutura , Anciano , Artroplastia , Fenómenos Biomecánicos , Cadáver , Femenino , Humanos , Húmero/cirugía , Masculino , Ensayo de Materiales , Persona de Mediana Edad , Falla de Prótesis , Estrés Mecánico
2.
Arthroscopy ; 35(7): 1954-1959.e4, 2019 07.
Artículo en Inglés | MEDLINE | ID: mdl-30979619

RESUMEN

PURPOSE: To evaluate the cyclic displacement and ultimate load to failure of 4 all-suture anchors in human cadaveric shoulder glenoid bone. METHODS: Four all-suture anchors indicated for glenoid labral repair were tested in 14 matched pairs of human cadaveric fresh-frozen glenoids. Anchors were inserted at 4 different locations for a total of 112 tests (12-, 3-, 6-, and 9-o'clock positions for right glenoids). Cyclic loading (10 to 60 N at 1 Hz for 200 cycles) and single pull-to-failure testing (33 mm/s) were performed. A Kruskal-Wallis 1-way analysis of variance with the Dunn multiple-comparison post hoc test was used for statistical analysis. RESULTS: One matched pair was excluded because of poor bone quality. Thus, 13 matched pairs were included in the study, and a total of 104 tests were performed. The Q-Fix anchors showed significantly less displacement after 100 cycles (mean ± standard deviation, 1.40 ± 0.97 mm; P < .001) and 200 cycles (1.53 ± 1.00 mm, P < .001) than all other anchors tested. The Q-Fix (191.3 ± 65.8 N), Suturefix (188.3 ± 61.4 N), and JuggerKnot (183.6 ± 63.5 N) anchors had significantly greater ultimate loads to failure than the Iconix anchors (143.5 ± 54.1 N) (P = .01, P = .012, and P = .021, respectively). Displacement greater than 5 mm occurred in 6 Iconix anchors (22.1%), 5 Suturefix anchors (19.2%), 4 JuggerKnot anchors (15.4%), and 0 Q-Fix anchors (0%). CONCLUSIONS: The Q-Fix anchors showed less displacement with cyclic loading than the Iconix, JuggerKnot, and Suturefix anchors. The Iconix anchors had a lower ultimate load to failure than the Q-Fix, Suturefix, and JuggerKnot anchors. Only the Q-Fix group had no anchors displace greater than 5 mm with cyclic loading. CLINICAL RELEVANCE: All-suture anchors vary in their deployment mechanism, which may alter their strength and performance. Operators must be aware of these anchors' propensity to displace while deploying them.


Asunto(s)
Artroscopía/métodos , Articulación del Hombro/cirugía , Anclas para Sutura , Técnicas de Sutura/instrumentación , Anciano , Fenómenos Biomecánicos , Cadáver , Humanos , Persona de Mediana Edad , Articulación del Hombro/fisiopatología
3.
Arthroscopy ; 34(10): 2777-2781, 2018 10.
Artículo en Inglés | MEDLINE | ID: mdl-30195950

RESUMEN

PURPOSE: To evaluate the effect of greater tuberosity decortication on ultimate load to failure and displacement after cyclic loading with an all-suture anchor. METHODS: A 2.9-mm all-suture anchor was evaluated in decorticated and nondecorticated greater tuberosities of 10 matched pairs of human cadaveric shoulders. Greater tuberosity decortication was performed to a mean depth of 1.7 mm. Anchors were placed in the anterior, middle, and posterior tuberosity. Anchors were tested under cyclic loads followed by load-to-failure testing. Displacement after 20, 100, and 200 cycles and ultimate failure strength were determined. Clinical failure was defined as displacement greater than 5 mm during cyclic loading. RESULTS: After 20 and 100 cycles, there was no difference in mean displacement between the decorticated and nondecorticated cohorts (P = .139 and P = .127, respectively). The mean displacement after 200 cycles was greater in the decorticated cohort, although not significantly (3.4 vs 2.7 mm; P = .05). The mean ultimate load to failure was significantly lower in the decorticated cohort (314 vs 386 N, P = .049). There were 2 clinical failures in the decorticated specimens and 1 in the nondecorticated specimens. CONCLUSIONS: A minimal greater tuberosity decortication significantly decreases the ultimate load to failure of an all-suture anchor. However, decreased biomechanical strength may not necessitate actual clinical failure. CLINICAL RELEVANCE: A decrease in ultimate load to failure could increase the risk of catastrophic postoperative anchor failure. However, while this decrease in strength is statistically significant, the overall decrease in strength may not be sufficient in magnitude to translate to clinical failure.


Asunto(s)
Artroplastia/métodos , Lesiones del Manguito de los Rotadores/cirugía , Manguito de los Rotadores/cirugía , Anclas para Sutura , Anciano , Fenómenos Biomecánicos , Cadáver , Femenino , Humanos , Masculino , Persona de Mediana Edad , Estrés Mecánico , Técnicas de Sutura
4.
Arthroscopy ; 34(5): 1384-1390, 2018 05.
Artículo en Inglés | MEDLINE | ID: mdl-29456066

RESUMEN

PURPOSE: To determine if the depth of anchor insertion affects the biomechanical performance of a 1.5-mm all-suture anchor in glenoid bone. METHODS: A 1.5-mm all-suture anchor was tested in 8 matched pairs of human cadaver fresh-frozen glenoids. Anchors were inserted at 6 different locations and tested at 3 different depths: 21 mm (preset drilling depth), 17 mm, and 13 mm. Cyclic loading and destructive testing was performed. Displacement after 100 and 200 cycles, along with ultimate failure strength, was determined. RESULTS: After 100 and 200 cycles, anchors placed at 13 and 17 mm had undergone significantly less displacement than those at 21 mm (P < .05). No difference was observed in ultimate load to failure between anchors placed at 21 and 17 mm. However, the ultimate load to failure was significantly lower in anchors placed at 13 mm (P < .05). There were 5 clinical failures in anchors placed at 21 mm, one at 17 mm, and none at 13 mm. CONCLUSIONS: The 1.5-mm all-suture anchor tested in this study has an optimal insertion depth of 17 mm, 4 mm shallower than the preset drill depth. At the optimal insertion depth of 17 mm, it underwent significantly less displacement after cyclic loading without a reduction in the ultimate load to failure. CLINICAL RELEVANCE: Given the results of this study, the optimal insertion depth for this 1.5-mm all-suture anchor is 17 mm, 4 mm shallower than the preset drill depth.


Asunto(s)
Artroscopía/instrumentación , Cavidad Glenoidea/fisiología , Cavidad Glenoidea/cirugía , Anclas para Sutura , Anciano , Fenómenos Biomecánicos , Cadáver , Humanos , Ensayo de Materiales , Persona de Mediana Edad , Técnicas de Sutura , Resistencia a la Tracción
5.
Arthroscopy ; 32(12): 2490-2494, 2016 12.
Artículo en Inglés | MEDLINE | ID: mdl-27614390

RESUMEN

PURPOSE: To quantify the distance of the dorsal ulnar sensory branch, floor of the extensor carpi ulnaris (ECU) subsheath, and ulnar neurovascular bundles from the triangular fibrocartilage complex (TFCC), and secondarily to assess the safety of an all-inside arthroscopic repair of the TFCC with a commonly used meniscal repair device with respect to the aforementioned structures. METHODS: A custom K-wire with 1-mm gradation was used to determine the distance of at-risk structures from the periphery of the TFCC in 13 above-elbow human cadaver specimens. An all-inside repair of the TFCC at the location of a Palmer 1B tear was then performed using a commonly employed meniscal repair device. The distance from the deployed devices to the structure in closest proximity was then measured using digital calipers. RESULTS: The mean distance from the deployed device to the nearest structure of concern for iatrogenic injury was 9.4 mm (range, 5-15 mm). The closest structure to iatrogenic injury was usually, but not always, the dorsal ulnar sensory nerve in 9 of 13 wrists (69.2%) at 9.3 mm (range, 5-15 mm); on 3 occasions it was instead the ulnar nerve (23.1%) at 9.5 mm (range, 9-10 mm), and on 1 occasion 6 mm from the flexor digitorum profundus to the little finger (7.7%). Forearm rotation had no significant effect on measured distances (ulnar nerve: P = .98; dorsal sensory: P = .89; ECU: P = .90). The largest influence of forearm rotation was a 0.4-mm difference between pronation and supination with respect to the distance of the TFCC periphery on the ECU subsheath. CONCLUSIONS: An all-inside arthroscopic TFCC repair using a commonly used meniscal repair device appears safe with respect to nearby neurovascular structures and tendons under typical arthroscopic conditions. CLINICAL RELEVANCE: An all-inside arthroscopic TFCC repair using a commonly employed meniscal repair device appears safe in terms of proximity to important structures although further clinical investigation is warranted.


Asunto(s)
Artroscopía/métodos , Fibrocartílago Triangular/anatomía & histología , Fibrocartílago Triangular/cirugía , Artroscopía/instrumentación , Cadáver , Humanos , Enfermedad Iatrogénica/prevención & control , Traumatismos de los Tendones/prevención & control , Tendones/anatomía & histología , Nervio Cubital/anatomía & histología
6.
J Sport Rehabil ; 25(3): 213-8, 2016 Aug.
Artículo en Inglés | MEDLINE | ID: mdl-27445119

RESUMEN

CONTEXT: Knee osteoarthritis (OA) is a debilitating disease that affects an estimated 27 million Americans. Changes in lower-extremity alignment and joint laxity have been found to redistribute the medial and/or lateral loads at the joint. However, the effect that changes in anteroposterior knee-joint laxity have on lower-extremity alignment and function in individuals with knee OA remains unclear. OBJECTIVE: To examine anteroposterior knee-joint laxity, lower-extremity alignment, and subjective pain, stiffness, and function scores in individuals with early-stage knee OA and matched controls and to determine if a relationship exists among these measures. DESIGN: Case control. SETTING: Sports-medicine research laboratory. PARTICIPANTS: 18 participants with knee OA and 18 healthy matched controls. INTERVENTION: Participants completed the Western Ontario McMaster (WOMAC) osteoarthritis questionnaire and were tested for total anteroposterior knee-joint laxity (A-P) and knee-joint alignment (ALIGN). MAIN OUTCOME MEASURES: WOMAC scores, A-P (mm), and ALIGN (°). RESULTS: A significant multivariate main effect for group (Wilks' Λ = 0.30, F7,26 = 8.58, P < .0001) was found. Knee-OA participants differed in WOMAC scores (P < .0001) but did not differ from healthy controls on ALIGN (P = .49) or total A-P (P = .66). No significant relationships were identified among main outcome measures. CONCLUSION: These data demonstrate that participants with early-stage knee OA had worse pain, stiffness, and functional outcome scores than the matched controls; however, ALIGN and A-P were no different. There was no association identified among participants' subjective scores, ALIGN, or A-P measures in this study.


Asunto(s)
Anteversión Ósea/etiología , Retroversión Ósea/etiología , Inestabilidad de la Articulación/etiología , Articulación de la Rodilla/fisiopatología , Extremidad Inferior/fisiopatología , Osteoartritis de la Rodilla/fisiopatología , Índice de Severidad de la Enfermedad , Anciano , Anteversión Ósea/diagnóstico , Anteversión Ósea/fisiopatología , Retroversión Ósea/diagnóstico , Retroversión Ósea/fisiopatología , Estudios de Casos y Controles , Femenino , Humanos , Inestabilidad de la Articulación/diagnóstico , Inestabilidad de la Articulación/fisiopatología , Masculino , Persona de Mediana Edad , Osteoartritis de la Rodilla/diagnóstico , Dimensión del Dolor , Calidad de Vida
7.
J Arthroplasty ; 27(6): 1183-9, 2012 Jun.
Artículo en Inglés | MEDLINE | ID: mdl-22386607

RESUMEN

Knee osteoarthritis (OA) accounts for more functional disability of the lower extremity than any other disease. We recruited 18 patients with knee OA and 18 healthy age-, height-, mass-, and gender-matched control subjects to investigate the effects knee OA has on select spatial and temporal gait variables during a stair climbing task. No group-by-direction interaction was observed; however, significant effects did occur for group and direction. Specifically, patients with knee OA demonstrated less time in single support, greater time in double support, decreased step length, greater step width, less stride length, decreased total gait velocity, greater total time in support, and less total time in swing, compared with controls. Early-stage knee OA directly influences specific temporal and spatial gait characteristics during stair climbing.


Asunto(s)
Adaptación Fisiológica/fisiología , Marcha/fisiología , Osteoartritis de la Rodilla/fisiopatología , Rango del Movimiento Articular/fisiología , Anciano , Fenómenos Biomecánicos , Estudios de Casos y Controles , Evaluación de la Discapacidad , Femenino , Humanos , Masculino , Persona de Mediana Edad , Factores de Tiempo , Caminata/fisiología
8.
J Surg Res ; 162(1): 148-52, 2010 Jul.
Artículo en Inglés | MEDLINE | ID: mdl-19783006

RESUMEN

BACKGROUND: Effectiveness of acellular human dermis (AHD) as an alternative to synthetic mesh in contaminated fields has been described. Cellular migration after implantation and corresponding strength of attachment is not well documented. Our aim is to correlate AHD vascularization, fibroblast migration, and strength of attachment with presence of inflammatory cells in clean and contaminated fields. MATERIALS AND METHODS: Lewis rats were randomized to a control and three experimental groups. AHD was placed as an onlay over the intact abdominal wall. Experimental groups (n=72) were exposed to Staphylococcus aureus at 1 x 10(4), 1 x 10(5), or 1 x 10(6) by direct application; controls (n=12) were not exposed. At 5 and 28 d, abdominal walls were explanted and tissue ingrowth assessed via tensiometry measuring energy (E) and max stress (MS) at the AHD-tissue interface. Vascularity, fibroblast migration, and inflammatory cell migration were compared using light microscopy. RESULTS: Shear strength reported as energy and max stress were significantly greater at 28 versus 5 d in all experimental groups, remaining unchanged in controls. Plasma cells and histiocytes significantly increased in all groups; macrophages increased in experimental groups only. Vascular ingrowth increased significantly in all groups; fibroblast migration was greater in controls and 1 x 10(6) exposed group only. CONCLUSIONS: Contamination of AHD results in inflammatory cell influx and a surprising increase in shear strength. Interestingly, shear strength does not increase without contamination. Inflammation stimulates vascular ingrowth, but not equally significant fibroblast migration. Longer survivals are required to determine if energy and max stress of controls increase, and fibroblast migration follows vascular ingrowth.


Asunto(s)
Bioprótesis/microbiología , Colágeno , Animales , Movimiento Celular , Fibroblastos/fisiología , Herniorrafia , Humanos , Masculino , Neovascularización Fisiológica , Distribución Aleatoria , Ratas , Ratas Endogámicas Lew
9.
J Orthop Trauma ; 34(1): e20-e25, 2020 Jan.
Artículo en Inglés | MEDLINE | ID: mdl-31567796

RESUMEN

OBJECTIVES: To describe surgical technique for proper placement of the clavicle hook plate, determine whether there is subacromial impingement caused by hook plate fixation, and evaluate the mechanical strength of the clavicle hook plate construct. METHODS: Eight fresh-frozen cadaveric shoulders with a mean age of 48 years (range, 37-69) were used. Open reduction and internal fixation of simulated Rockwood type V AC joint dislocation was performed with the clavicle hook plate. Three-dimensional computed tomography studies and arthroscopic evaluation were performed with the glenohumeral joint in different orientations to assess the position of the hook plate relative to relevant joint structures. The clavicle was then superiorly loaded to mechanical failure. RESULTS: Computed tomography evaluations showed no contact between the humerus and the hook plate. Distance between the greater tuberosity and hook plate ranged from 14 to 31 mm with maximal shoulder forward flexion and 8.1-25.4 mm with maximal shoulder abduction. Arthroscopic evaluation of the subacromial space demonstrated that with maximal abduction/forward flexion, there was abutment of the rotator cuff with the hook plate in 6 of 8 specimens. In mechanical testing, mean failure load was determined to be 1011 N (range, 380-1563 N). Failure mechanisms included acromion fracture (4), slippage of the hook under acromion (3), and distal clavicle fracture (1). CONCLUSIONS: This study demonstrates that the clavicle hook plate reduces AC joint dislocation or distal clavicle fractures anatomically, has supra-physiologic mechanical strength, does not cause bony impingement, and exhibits rotator cuff impingement only with maximal abduction/forward flexion of the shoulder.


Asunto(s)
Articulación Acromioclavicular , Luxaciones Articulares , Articulación Acromioclavicular/diagnóstico por imagen , Articulación Acromioclavicular/cirugía , Acromion , Adulto , Anciano , Placas Óseas , Cadáver , Clavícula/diagnóstico por imagen , Clavícula/cirugía , Fijación Interna de Fracturas , Humanos , Persona de Mediana Edad , Resultado del Tratamiento
10.
Gait Posture ; 76: 193-197, 2020 02.
Artículo en Inglés | MEDLINE | ID: mdl-31862669

RESUMEN

BACKGROUND: Wearable sensors have allowed researchers to instrument tests of gait-related mobility, including the widely used timed 'up-and-go' test (TUG). Currently, there is a lack of instrumented test data on whether children with moderate to severe traumatic brain injury (TBI) perform differently on the TUG compared to typically developed (TD) controls during a cognitive-motor task. RESEARCH QUESTION: The aim was to explore the effects of a cognitive-motor task on TUG subcomponents among children with TBI compared to TD children. METHODS: This observational cross-sectional study included 12 children with moderate to severe TBI (6 males and 6 females, age 10.5 ±â€¯1.5 years of age) and 10 age and sex-matched TD controls (5 males and 5 females, 10.4 ±â€¯1.3 years of age). Each participant completed 6 trials of the TUG wearing a single inertial measurement unit sensor at a self-selected walking pace while listening to an array of 10 randomly presented single digits during each TUG trial. RESULTS: Total time to complete the TUG was not significantly different between groups. The cognitive-motor task led to significantly lower mean turn and peak turn angular velocity values during the turn-around-the-cone and turn-before-sitting TUG subcomponents in children with TBI compared to the TD controls (p ≤ 0.05). Additionally, the cognitive-motor task led to significantly lower values for maximum torso flexion to extension angle, peak flexion and extension angular velocity and peak vertical acceleration for the sit-to-stand subcomponent (p < 0.05). Peak flexion angular velocity during the stand-to-sit subcomponent was lower for the TBI group compared to the children with TD (p < 0.05). SIGNIFICANCE: The study provides new insights into the performance of complex gait-related mobility tasks in the context of an instrumented TUG among children with moderate to severe TBI. Our results highlight the potential benefits of outfitting pediatric inpatients with an IMU while completing the TUG.


Asunto(s)
Lesiones Traumáticas del Encéfalo/fisiopatología , Desarrollo Infantil , Marcha/fisiología , Tamizaje Masivo/métodos , Equilibrio Postural/fisiología , Velocidad al Caminar/fisiología , Aceleración , Adolescente , Lesiones Traumáticas del Encéfalo/diagnóstico , Niño , Estudios Transversales , Femenino , Humanos , Masculino , Estudios de Tiempo y Movimiento , Torso/fisiopatología
11.
Surg Endosc ; 23(4): 800-7, 2009 Apr.
Artículo en Inglés | MEDLINE | ID: mdl-18830746

RESUMEN

INTRODUCTION: The addition of staple-line reinforcements on circular anastomoses has not been well studied. We histologically and mechanically analyzed circular- stapled anastomoses with and without bioabsorbable staple-line reinforcement (SeamGuard, W. L. Gore & Associates, Flagstaff, AZ) in a porcine model. METHODS: Gastrojejunal anastomoses were constructed using a #25 EEA Proximate ILS (Ethicon Endo-Surgery, Cincinnati, OH) mechanical stapling device with and without Bioabsorbable SeamGuard (BSG). Gastrojejunal anastomoses were resected acutely and at 1 week, and burst-pressure testing and histological analysis were performed. Standardized grading systems for inflammation, collagen deposition, vascularity, and serosal inflammation were used to compare the two anastomosis types. RESULTS: Acute burst pressures were significantly higher with BSG than with staples alone (1.37 versus 0.39 psi, p=0.0075). Burst pressures at 1 week were significantly lower with BSG than with staples alone (2.24 versus 3.86 psi, p=0.0353); however, both readings were above normal physiologic intestinal pressures. There was no statistical difference in inflammation (13.4 versus 15.6, p=0.073), width of mucosa (3.2 mm versus 3.2 mm, p=0.974), adhesion formation (0 versus 0.5, p=0.575), number of blood vessels (0.5 versus 1.0, p=0.056), or serosal inflammation (2.0 versus 1.0, p=0.27) between the stapled anastomoses and those buttressed with BSG. Stapled-only anastomoses had statistically more collagen (2.0 versus 1.0, p=0.005) than the anastomoses supported with BSG. CONCLUSIONS: The addition of BSG as a staple-line reinforcement acutely improves the burst strength of a circular anastomosis but not at 1 week. At 1 week, a decrease in collagen content with the BSG-buttressed stapled anastomosis was the only difference in the histologic parameters studied with no difference in vascularity, adhesions, or inflammation. The long-term effect of BSG on anastomotic strength or scarring is yet to be determined. The clinical implications may include decreased stricture formation and also decreased strength at anastomoses.


Asunto(s)
Materiales Biocompatibles , Yeyuno/cirugía , Estómago/cirugía , Grapado Quirúrgico/instrumentación , Suturas , Anastomosis en-Y de Roux/métodos , Animales , Colágeno/metabolismo , Modelos Animales de Enfermedad , Diseño de Equipo , Femenino , Mucosa Intestinal/metabolismo , Mucosa Intestinal/patología , Yeyuno/patología , Yeyuno/fisiopatología , Presión , Estómago/patología , Estómago/fisiopatología , Porcinos
12.
Arthroscopy ; 24(4): 383-8, 2008 Apr.
Artículo en Inglés | MEDLINE | ID: mdl-18375268

RESUMEN

PURPOSE: The purpose of this study was to biomechanically compare 2 different suture anchor configurations in the repair of type II SLAP lesions. METHODS: Standardized type II SLAP lesions were created in 8 matched pairs of cadaveric shoulders. Two different suture anchor configurations were used to repair the type II SLAP lesions. Group 1 SLAP lesions were repaired with 1 suture anchor placed at the anterior border and a second suture anchor placed at the posterior border of the biceps tendon. Group 2 SLAP lesions were repaired with 2 suture anchors placed posterior to the biceps tendon. Biomechanical testing was conducted in 1 direction. A posterior-directed force, in the plane of the glenoid, simulated the peel-back mechanism that occurs during the late cocking phase of throwing. Biceps-labral complex displacement from the glenoid was measured with 2 miniature displacement transducers. Repair failure (2 mm of posterior labral displacement), ultimate failure, and construct stiffness were measured for each specimen. RESULTS: The mean load to repair failure was 43.66 N in group 1 and 40.70 N in group 2. The mean load to ultimate failure was 156.28 N in group 1 and 162.06 N in group 2. The mean construct stiffness was 25.91 N/mm in group 1 and 30.28 N/mm in group 2. The differences between the 2 groups were not statistically significant in terms of repair failure, ultimate failure, and construct stiffness. CONCLUSIONS: When repaired type II SLAP lesions were subjected to a posterior vector load to simulate the peel-back mechanism, the 2 suture anchor configurations were biomechanically equivalent. CLINICAL RELEVANCE: Placement of an anterior suture anchor could, theoretically, tension the anterior capsulolabral structures via the superior and middle glenohumeral ligaments to the superior labrum. The results of this study suggest that there is no biomechanical advantage to placing an anterior suture anchor and so the use of 2 posterior suture anchors may be preferable in the repair of type II SLAP lesions.


Asunto(s)
Fenómenos Biomecánicos , Ligamentos Articulares/cirugía , Procedimientos Ortopédicos/métodos , Articulación del Hombro/cirugía , Anclas para Sutura , Adulto , Artroscopía , Cadáver , Femenino , Humanos , Ligamentos Articulares/lesiones , Masculino , Persona de Mediana Edad , Probabilidad , Distribución Aleatoria , Sensibilidad y Especificidad , Lesiones del Hombro , Técnicas de Sutura , Resistencia a la Tracción
13.
J Arthroplasty ; 23(6): 873-8, 2008 Sep.
Artículo en Inglés | MEDLINE | ID: mdl-18534544

RESUMEN

Cementing polyethylene liners into well-fixed metal shells at revision total hip arthroplasty is an accepted technique. Previous studies have tested the initial strength of this construct, but none have tested the construct under physiologic and abnormal loading conditions. The current study examines liner-shell performance under these conditions. In addition, this study quantitates whether hand-modified regular liners or liners designed for cementation with integrated cement spacers, which provide an even cement mantle, perform better. Cyclic loads of up to 4000 N for 500,000 cycles followed by 2000 N for 200,000 cycles of edge loading were used. The liners with integrated spacers demonstrated higher lever-out moments and statistically significant increase in tear-out loads.


Asunto(s)
Artroplastia de Reemplazo de Cadera/instrumentación , Cementos para Huesos , Prótesis de Cadera , Metales , Polietileno , Fenómenos Biomecánicos , Articulación de la Cadera/fisiología , Articulación de la Cadera/cirugía , Humanos , Modelos Biológicos , Diseño de Prótesis , Reoperación , Soporte de Peso/fisiología
14.
Gait Posture ; 63: 248-253, 2018 06.
Artículo en Inglés | MEDLINE | ID: mdl-29778065

RESUMEN

BACKGROUND: Studies have evaluated the test-re-test reliability of subcomponents of the timed up and-go test in adults by using body-worn inertial sensors. However, studies in children have not been reported in the literature. RESEARCH QUESTION: To evaluate the within-session reliability of subcomponents of a newly developed electronically augmented timed 'upand-go' test (EATUG) in ambulatory children with traumatic brain injury (TBI) and children with typical development (TD). METHOD: The timed up and go test was administered to twelve consecutive ambulatory children with moderate to severe TBI (6 males and 6 females, age 10.5 ±â€¯1.5 years, range 8-13 years, during inpatient rehabilitation at 27.0 ±â€¯11.8 days following injury) and 10 TD age and sex-matched children (5 males and 5 females, 10.4 ±â€¯1.3 years, range 8-11 years). Participants wore a single chest-mounted inertial measurement sensor package with custom software that measured angular and acceleration velocity and torso flexion and extension angles, while they performed 6 trials of the EATUG test. Measures were derived from the overall time to complete the TUG test, angular velocity and angular displacement data for torso flexion and extension during sit-to-stand and stand-to-sit segments and both mean and peak angular velocities for two turning segments (i.e. turning around a cone and turning-before-sitting). RESULTS: Within-session reliability of the subcomponents of the TUG test for children with TBI assessed by the intra-class correlation coefficient was ICC (1,1) = 0.84, (range 0.82-0.96), and for TD children ICC (1,1) = 0.73, (range 0.53-0.89). Scores on Total Time, maximum torso flexion/extension angle and peak flexion angular velocity during sit-tostand, and peak turn angular velocity for both turns around the cone and turns before sitting were lower for children with TBI than for TD children (p ≤ 0.05). SIGNIFICANCE: The EATUG test is a reliable measure of physical function in children with TBI who are being discharged from inpatient rehabilitation.


Asunto(s)
Lesiones Traumáticas del Encéfalo/diagnóstico , Actividad Motora/fisiología , Postura , Tiempo de Reacción , Procesamiento de Señales Asistido por Computador/instrumentación , Aceleración , Adolescente , Lesiones Traumáticas del Encéfalo/fisiopatología , Lesiones Traumáticas del Encéfalo/rehabilitación , Niño , Femenino , Humanos , Masculino , Reproducibilidad de los Resultados , Torso
15.
Arthroscopy ; 23(2): 141-50, 2007 Feb.
Artículo en Inglés | MEDLINE | ID: mdl-17276221

RESUMEN

PURPOSE: To biomechanically compare the Jobe transosseous ulnar collateral ligament (UCL) reconstruction procedure and an interference screw reconstruction (ISR) technique versus the intact elbow UCL. METHODS: Intact stiffness of 10 matched cadaveric elbow pairs was tested via submaximal valgus loading at 4 flexion angles. From each pair, a metal ISR and a traditional transosseous Jobe reconstruction was performed with the use of matched hamstring tendon grafts. Initial stiffness (graft tension), overall stiffness, strain, and failure strength of reconstructed elbows were then tested. RESULTS: At each tested flexion angle, Jobe constructs reproduced the initial and overall stiffness of the intact ligament. ISR constructs did not reproduce the overall stiffness of the native ligament at any flexion angle, and they reproduced the initial stiffness only at 30 degrees and 120 degrees of flexion. Jobe constructs were significantly stronger, failing (10 degrees of displacement) at 22.7 Nm after absorbing 1.58 Nm of energy, versus 13.4 Nm and 0.97 Nm for ISR constructs. In all, 40% of bone tunnel reconstructions failed via tunnel fracture, and 70% of interference screw constructs failed via graft slippage. CONCLUSIONS: The failure strength and initial and overall stiffness of a traditional Jobe bone tunnel UCL reconstruction are superior to those of an ISR, and only traditional Jobe bone tunnel reconstruction reproduces the initial and overall stiffness of an intact UCL. CLINICAL RELEVANCE: Many UCL reconstruction techniques have been described, and a paucity of biomechanical data supports their use. This study found the Jobe bone tunnel technique to be biomechanically superior to the ISR technique.


Asunto(s)
Ligamentos Colaterales/cirugía , Articulación del Codo/cirugía , Procedimientos Ortopédicos/métodos , Cúbito , Anciano , Anciano de 80 o más Años , Fenómenos Biomecánicos , Tornillos Óseos , Cadáver , Femenino , Humanos , Masculino , Persona de Mediana Edad , Tendones/trasplante , Lesiones de Codo
16.
Orthop J Sports Med ; 5(8): 2325967117719857, 2017 Aug.
Artículo en Inglés | MEDLINE | ID: mdl-28840144

RESUMEN

BACKGROUND: Improved biomechanical and clinical outcomes are seen when the femoral tunnels of the anterior cruciate ligament (ACL) are placed in the center of the femoral insertion. The transtibial (TT) technique has been shown to be less capable of this than an anteromedial (AM) portal approach but is more familiar to surgeons and less technically challenging. A hybrid transtibial (HTT) technique using medial portal guidance of a transtibial guide wire without knee hyperflexion may offer anatomic tunnel placement while maintaining the relative ease of a TT technique. PURPOSE: To evaluate the anatomic and biomechanical performance of the HTT technique compared with TT and AM approaches. STUDY DESIGN: Controlled laboratory study. METHODS: Thirty-six paired, fresh-frozen human knees were used. Twenty-four knees (12 pairs) underwent all 3 techniques (TT, AM, HTT) for femoral tunnel placement, with direct measurement of femoral insertional overlap and femoral tunnel length. The remaining 12 knees (6 pairs) underwent completed reconstructions to evaluate graft anisometry and tunnel orientation, with each technique performed in 4 specimens and tested using motion sensors with a quad-load induced model. Graft length changes and graft/femoral tunnel angle were measured at varying degrees of flexion. RESULTS: Percentage overlap of the femoral insertion averaged 37.0% ± 28.6% for TT, 93.9% ± 5.6% for HTT, and 79.7% ± 7.7% for AM, with HTT significantly greater than both TT (P = .007) and AM (P = .001) approaches. Graft length change during knee flexion (anisometry) was 30.1% for HTT, 12.8% for AM, and 8.5% for TT. When compared with the TT approach, HTT constructs exhibited comparable graft-femoral tunnel angulation (TT, 150° ± 3° vs HTT, 142° ± 2.3°; P < .001) and length (TT, 42.6 ± 2.8 mm vs HTT, 38.5 ± 2.0 mm; P = .12), while AM portal tunnels were significantly shorter (31.6 ± 1.6 mm; P = .001) and more angulated (121° ± 6.5°; P < .001). CONCLUSION: The HTT technique avoids hyperflexion and maintains femoral tunnel orientation and length, similar to the TT technique, but simultaneously achieves anatomic graft positioning. CLINICAL RELEVANCE: The HTT technique offers an anatomic alternative to an AM portal approach while maintaining the technical advantages of a traditional TT reconstruction.

17.
Am Surg ; 72(9): 808-13; discussion 813-4, 2006 Sep.
Artículo en Inglés | MEDLINE | ID: mdl-16986391

RESUMEN

Laparoscopic ventral hernia repair requires an intraperitoneal prosthetic; however, these materials are not without consequences. We evaluated host reaction to intraperitoneal placement of various prosthetics and the functional outcomes in an animal model. Mesh (n = 15 per mesh type) was implanted on intact peritoneum in New Zealand white rabbits. The mesh types included ePTFE (DualMesh), ePTFE and polypropylene (Composix), polypropylene and oxidized regenerated cellulose (Proceed), and polypropylene (Marlex). Adhesion formation was evaluated at 1, 4, 8, and 16 weeks using 2-mm mini-laparoscopy. Adhesion area, adhesion tenacity, prosthetic shrinkage, and compliance were evaluated after mesh explantation at 16 weeks. DualMesh had significantly less adhesions than Proceed, Composix, or Marlex at 1, 4, 8, and 16 weeks (P < 0.0001). Marlex had significantly more adhesions than other meshes at each time point (P < 0.0001). There were no statistically significant differences in adhesions between Proceed and Composix meshes. After mesh explantation, the mean area of adhesions for Proceed (4.6%) was less than for Marlex (21.7%; P = 0.001). The adhesions to Marlex were statistically more tenacious than the DualMesh and Composix groups. Overall prosthetic shrinkage was statistically greater for DualMesh (34.7%) than for the remaining mesh types (P < 0.01). Mesh compliance was similar between the groups. Prosthetic materials demonstrate a wide variety of characteristics when placed inside the abdomen. Marlex formed more adhesions with greater tenacity than the other mesh types. DualMesh resulted in minimal adhesions, but it shrank more than the other mesh types. Each prosthetic generates a varied host reaction. Better understanding of these reactions can allow a suitable prosthetic to be chosen for a given patient in clinical practice.


Asunto(s)
Materiales Biocompatibles/efectos adversos , Hernia Ventral/cirugía , Prótesis e Implantes/efectos adversos , Mallas Quirúrgicas/efectos adversos , Adherencias Tisulares/etiología , Animales , Modelos Animales de Enfermedad , Polímeros de Fluorocarbono/efectos adversos , Laparoscopía/efectos adversos , Laparoscopía/métodos , Polipropilenos/efectos adversos , Estudios Prospectivos , Conejos
18.
J Orthop Trauma ; 20(8): 547-54, 2006 Sep.
Artículo en Inglés | MEDLINE | ID: mdl-16990726

RESUMEN

OBJECTIVE: To compare the mechanical stability of a fixed-angle blade plate with that of a locking plate in a cadaveric proximal humerus fracture-fixation model subjected to cyclic loading. A secondary objective was to evaluate whether the use of synthetic humerus specimens would replicate significant differences found during cadaveric tests. DESIGN: Mechanical evaluation of constructs in bending and torsion. SETTING: Biomechanical laboratory in an academic medical center. METHODS: Simulated humeral neck fractures (Orthopaedic Trauma Association (OTA) classification 11A3), in matched-pair cadaveric and synthetic specimens underwent fixation using either a 3.5-mm, 90-degree cannulated LC-Angled Blade Plate or a 3.5-mm LCP Proximal Humerus Locking Plate. Cadaveric specimen constructs were cyclically loaded in bending and torsion; synthetic specimens were tested in torsion. MAIN OUTCOME MEASURE: Humeral shaft-bending displacements and angular rotations for respective cyclic bending loads and axial torques were recorded and compared at repeated cyclic intervals to evaluate construct loosening. RESULTS: Locking-plate constructs exhibited significantly less loosening than blade-plate constructs for torsional loading in cadaveric specimens (P = 0.036). The two types of constructs performed similarly for torsional loading in synthetic specimens (P = 0.100). Under cyclic, closed-bending load conditions in which the plates served as tension members, both types of constructs performed similarly in cadaveric specimens (P = 0.079). CONCLUSIONS: For simulated humeral neck fractures subjected to cyclic loading, locking-plate constructs demonstrated significantly greater torsional stability and similar bending stability to blade plates in a cadaveric specimen model. In contrast, these same constructs performed similarly with torsional loading when using synthetic humerus specimens. These results indicate potential advantages for locking-plate fixation. They also indicate that the synthetic specimens tested may not be appropriate for evaluating fixation stability in the humeral head, where cancellous bone fixation predominates.


Asunto(s)
Placas Óseas , Fijación de Fractura/métodos , Modelos Biológicos , Procedimientos Ortopédicos/métodos , Fracturas del Hombro/cirugía , Fenómenos Biomecánicos , Cadáver , Diseño de Equipo , Humanos
19.
Am J Sports Med ; 44(10): 2622-2628, 2016 Oct.
Artículo en Inglés | MEDLINE | ID: mdl-27390345

RESUMEN

BACKGROUND: Patellar tendon ruptures require surgical repair to optimize outcomes, but no consensus exists regarding the ideal repair technique. Cortical button fixation is a secure method for tendon repair that has not been studied in patellar tendons. HYPOTHESIS: Cortical button repair is biomechanically superior to the standard transpatellar repair and biomechanically equivalent to suture anchor repair. STUDY DESIGN: Controlled laboratory study. METHODS: Twenty-three fresh-frozen cadaveric knees were used to compare 3 techniques of patellar tendon repair after a simulated rupture at the inferior pole of the patella. Repairs were performed at 45° of flexion using a standard transpatellar suture repair (n = 7), polyetheretherketone (PEEK) suture anchor repair (n = 8), or cortical button repair (n = 8). All specimens were tested on a custom apparatus to simulate cyclic open kinetic chain quadriceps contraction from extension to 90o of flexion. Outcomes of gap formation up to 250 cycles, maximum load to failure, and mode of failure were evaluated. RESULTS: Cortical button repair had significantly less gap formation than anchor repair after 1 cycle (P < .001) and 20 cycles (P < .01) and significantly less gap formation than suture repair from 1 to 250 cycles (P < .05). Cortical button repair sustained significantly higher loads to failure than anchor repair and suture repair (P < .001). All suture repairs failed through the suture. Anchor repairs failed at the suture-anchor eyelet interface (n = 4) or by anchor pullout (n = 3). Cortical button repairs either failed through the suture (n = 5), secondary failure of the patellar tendon (n = 2), or subsidence of the button through the anterior cortex of the patella (n = 1). CONCLUSION: Patellar tendon repair using cortical button fixation demonstrated mechanical advantages over suture repair and anchor repair in cadaveric specimens. Cortical button fixation showed less cyclic gap formation and withstood at least twice the load to failure of the construct. CLINICAL RELEVANCE: The biomechanical superiority of cortical button fixation may impart clinical advantages in accelerating postoperative rehabilitation.


Asunto(s)
Rótula/cirugía , Ligamento Rotuliano/cirugía , Anclas para Sutura , Traumatismos de los Tendones/cirugía , Adulto , Anciano , Fenómenos Biomecánicos , Cadáver , Femenino , Humanos , Traumatismos de la Rodilla/cirugía , Masculino , Persona de Mediana Edad , Músculo Cuádriceps/cirugía , Rango del Movimiento Articular , Rotura/cirugía , Técnicas de Sutura , Suturas , Tendones/cirugía
20.
Arthroscopy ; 21(1): 69-76, 2005 Jan.
Artículo en Inglés | MEDLINE | ID: mdl-15650669

RESUMEN

PURPOSE: To determine the role of arthroscopic knot-tying instrumentation in achieving knot security. TYPE OF STUDY: Biomechanical study. METHODS: The security achieved by 3 different commercially available knot-tying instruments using No. 2 braided suture and a standardized knot configuration was compared. Instrumentation included (1) a single-hole knot pusher, (2) a cannulated double-diameter knot pusher, and (3) a mechanical end-splitting knot tightener. Hand-tied knots served as controls. Testing included both cyclic loading and load to failure parameters using the Bionix 858 (MTS Inc, Eden Prairie, MN) and Instron Mini 44 (Instron, Canton, MA) materials testing systems, respectively. An experienced arthroscopic shoulder surgeon and a less experienced junior-level orthopaedic resident surgeon performed tying. RESULTS: Knot displacement after cyclic loading was smallest for the mechanical end-splitting knot tightener (average, 0.054 mm) and did not differ statistically from hand-tied knots (average, 0.058 mm). Knots tied with this device also withstood the greatest load to failure (average, 126.0 N) and were statistically similar to hand-tied knots (average, 134.1 N). The single-hole pusher had an average cyclic loading displacement of 0.095 mm and failed at 108.6 N. The cannulated double-diameter pushers had an average cyclic loading displacement of 0.106 mm and failed at 93.1 N. Both were statistically less secure than hand-tied knots or those tied with the end-splitting tightener. Investigator experience did not affect knot security with those tied by the mechanical end-splitting tightener or hand-tied knots. CONCLUSIONS: The end-splitting tightener provided the most secure arthroscopic knots that were statistically as secure as those tied by hand for both investigators. The knot-tying instrument used in arthroscopic shoulder surgery may be an important consideration with potential clinical implications based on knot security. CLINICAL RELEVANCE: The specific knot tying instrument that is selected for use in arthroscopic shoulder surgery may play an important role in the degree of ultimate knot security achieved in suture repair.


Asunto(s)
Artroscopía , Articulación del Hombro/cirugía , Técnicas de Sutura/instrumentación , Técnicas de Sutura/normas , Fenómenos Biomecánicos