1.
Int Orthop ; 48(1): 291-299, 2024 Jan.
Artículo en Inglés | MEDLINE | ID: mdl-37624407

RESUMEN

PURPOSE: The Chiari pelvic osteotomy was the first surgical procedure to address hip dysplasia by changing the position of the acetabulum by medialization, thus creating a bony roof and improving biomechanical conditions. The aim of this retrospective cohort study was to report on the very long-term results of this technique. METHODS: Out of a consecutive series of 1536 hips, 504 in 405 patients were available for follow-up. The patients were assessed by physical and radiological examination. A Kaplan-Meier survival analysis with total hip arthroplasty as an endpoint was performed and stratified for age groups, pre-operative diagnosis, sex and osteoarthritis stage. RESULTS: The average follow-up was 36 ± 8.1 years (range, 35.2 to 54). The average pain level on the Visual Analogue Scale was 2.9 ± 2.6 (range 0 to 8.7). The average Harris Hip Score was 80.2 ± 17.4 (range 17.4 to 100). Correction of dysplasia was effective and remained stable over time. Osteoarthritis significantly increased over time with 53% Tönnis grade 3 at follow-up. The cumulative survivorship was 79.8% (95% confidence interval (CI), 76.1-83.2%) at 20 years, 57.1% (95% CI, 52.8-61.8%) at 30 years and 35% (95% CI, 30.3-40.3%) at 40 years. Young age, male sex and low osteoarthritis grade were positive prognostic factors. CONCLUSIONS: Although the Chiari pelvic osteotomy is considered a salvage procedure nowadays, it achieved excellent long-term results even in indications, which would be treated differently today. Young patients without osteoarthritis had the best outcome.


Asunto(s)
Luxación Congénita de la Cadera , Luxación de la Cadera , Osteoartritis de la Cadera , Humanos , Masculino , Luxación de la Cadera/cirugía , Estudios de Seguimiento , Estudios Retrospectivos , Resultado del Tratamiento , Luxación Congénita de la Cadera/cirugía , Acetábulo/cirugía , Osteoartritis de la Cadera/etiología , Osteoartritis de la Cadera/cirugía , Osteotomía/efectos adversos , Osteotomía/métodos
2.
J Arthroplasty ; 35(12): 3638-3643, 2020 12.
Artículo en Inglés | MEDLINE | ID: mdl-32674940

RESUMEN

BACKGROUND: Controversy exists whether previous pelvic osteotomies have negative effects on total hip arthroplasty (THA). This study evaluates the implant survival and patient-reported outcomes of THA after previous Chiari pelvic osteotomy (CPO). METHODS: Data on 301 THAs after CPO were collected through clinical and radiological follow-up examinations and telephone interviews. The Kaplan-Meier survivorship analysis depicts implant survival. RESULTS: Of this consecutive series of 1536 CPOs, follow-up was completed in 405 patients with 504 CPOs after a mean time of 36 years (±8; range, 22-54 years). At follow-up, 301 hips (60%) had already undergone THA. The overall survival of THA with revision as an end point after 10, 20, and 25 years was 93%, 76%, and 68%, respectively. The revision rate was 12%. The average period between THA and revision surgery was 9.6 years (±6.1; 4 months-25.4 years). The patient's age at revision was 57.9 years (±10; 33.2-78.5 years). Aseptic loosening was the most common of the known reasons for revision surgery. CONCLUSION: This retrospective study supports the hypothesis that prior CPO does not compromise the prerequisites for successful THA at a later stage. Survival rates of the implanted prosthesis are comparable to primary implanted hips, as overall survival was 93% after 10 years.


Asunto(s)
Artroplastia de Reemplazo de Cadera , Prótesis de Cadera , Artroplastia de Reemplazo de Cadera/efectos adversos , Estudios de Seguimiento , Articulación de la Cadera/cirugía , Prótesis de Cadera/efectos adversos , Humanos , Osteotomía , Falla de Prótesis , Reoperación , Estudios Retrospectivos , Resultado del Tratamiento
3.
Children (Basel) ; 10(10)2023 Sep 24.
Artículo en Inglés | MEDLINE | ID: mdl-37892256

RESUMEN

Several authors observed a loss of correction after performing Chiari pelvic osteotomy (CPO) in young patients. Hence, the aim of this study was to answer two questions: (1) Does the Chiari pelvic osteotomy affect the development of the acetabulum in skeletally immature patients in the long term? (2) Is there any evidence of the previously described "Anti-Chiari" effect after a mean follow-up of 36 years? Data from 21 patients (27 hips) undergoing CPO before the age of 16 years were clinically assessed, and the evolution of radiological parameters over time was analyzed. The mean age at CPO was 11.2 years (±3; 4.4-15.7). The 20- and 30-year survival rates of the CPO were 100% and 92.6%, respectively. Mean postoperative medialization was 54% (±18; 23-99). The average osteotomy angle was 11° (±7; 2-28). No significant changes were found for the center-edge angle (CEA) and acetabular index (AI) over time; the angle of Idelberger and Frank (ACM) almost reached normal values at follow-up (FU); for the acetabular-head index (AHI), a slight shift toward the initial situation could be detected. The morphology of the acetabulum remained unchanged over time. The "Anti-Chiari effect" seems to be primarily caused by insufficient coverage of the femoral head rather than damage to the apophysis due to surgery.

4.
Eur Radiol ; 19(10): 2416-24, 2009 Oct.
Artículo en Inglés | MEDLINE | ID: mdl-19440716

RESUMEN

The purpose of this study was to retrospectively assess the detection rate of skull-base fractures for three different three-dimensional (3D) reconstruction methods of cranial CT examinations in trauma patients. A total of 130 cranial CT examinations of patients with previous head trauma were subjected to 3D reconstruction of the skull base, using solid (SVR) and transparent (TVR) volume-rendering technique and maximum intensity projection (MIP). Three radiologists independently evaluated all reconstructions as well as standard high-resolution multiplanar reformations (HR-MPRs). Mean fracture detection rates for all readers reading rotating reconstructions were 39, 36, 61 and 64% for SVR, TVR, MIP and HR-MPR respectively. Although not significantly different from HR-MPR with respect to sensitivity (P = 0.9), MIP visualised 18% of fractures that were not reported in HR-MPR. Because of the relatively low detection rate using HR-MPRs alone, we recommend reading MIP reconstructions in addition to the obligatory HR-MPRs to improve fracture detection.


Asunto(s)
Algoritmos , Imagenología Tridimensional/métodos , Interpretación de Imagen Radiográfica Asistida por Computador/métodos , Base del Cráneo/diagnóstico por imagen , Base del Cráneo/lesiones , Fracturas Craneales/diagnóstico por imagen , Tomografía Computarizada por Rayos X/métodos , Adolescente , Adulto , Anciano , Anciano de 80 o más Años , Niño , Femenino , Humanos , Masculino , Persona de Mediana Edad , Intensificación de Imagen Radiográfica/métodos , Reproducibilidad de los Resultados , Sensibilidad y Especificidad , Adulto Joven
5.
Clin Orthop Relat Res ; 467(9): 2215-20, 2009 Sep.
Artículo en Inglés | MEDLINE | ID: mdl-19521741

RESUMEN

UNLABELLED: Fifty-six years after the introduction of Chiari's pelvic osteotomy, we report the long-term function scores and radiographic grade of osteoarthritis in 66 patients with 80 pelvic osteotomies with a minimum followup time of 27 years (average, 32 years; range, 27-48 years). These 66 patients were those who could be contacted and who returned for a followup visit from among 450 patients operated between 1961 and 1981. Thirty-two hips (40%) in 28 patients had undergone a total joint arthroplasty after an average 26 years (range, 13-41 years). Forty-eight hips in 41 patients (60%) were not replaced, their Harris hip score being a median of 82 points (range, 37-100 points). For the 22 patients for whom we had complete radiographs the average preoperative CE angle was 11.6 degrees, 48.6 degrees (range, 31 degrees-82.8 degrees) immediately postoperatively, and 41.6 degrees (range, 13.7 degrees-90 degrees) at last followup . Despite a functional hip score in most patients retaining their native hip, the degree of osteoarthritis progressed at last followup. We observed a similar mean age at the time of osteotomy in patients converted to total hip arthroplasty and those retaining their native hip. Age at time of surgery was inversely correlated (r = -0.78) with the interval between the osteotomy and THA. In this select patient group we found good functional outcome in patients who underwent Chiari pelvic osteotomy, with a conversion rate of 40% to total hip arthroplasty a mean of 32 years after the procedure. LEVEL OF EVIDENCE: Level IV, case series. See Guidelines for Authors for a complete description of levels of evidence.


Asunto(s)
Luxación Congénita de la Cadera/cirugía , Osteotomía/métodos , Huesos Pélvicos/cirugía , Complicaciones Posoperatorias/etiología , Adulto , Artroplastia de Reemplazo de Cadera , Progresión de la Enfermedad , Femenino , Estudios de Seguimiento , Luxación Congénita de la Cadera/complicaciones , Luxación Congénita de la Cadera/fisiopatología , Articulación de la Cadera/fisiopatología , Articulación de la Cadera/cirugía , Humanos , Masculino , Persona de Mediana Edad , Osteoartritis de la Cadera/diagnóstico por imagen , Osteoartritis de la Cadera/etiología , Osteoartritis de la Cadera/cirugía , Huesos Pélvicos/diagnóstico por imagen , Huesos Pélvicos/patología , Complicaciones Posoperatorias/cirugía , Radiografía , Rango del Movimiento Articular , Índice de Severidad de la Enfermedad , Resultado del Tratamiento
6.
Eur Radiol ; 18(11): 2512-21, 2008 Nov.
Artículo en Inglés | MEDLINE | ID: mdl-18504592

RESUMEN

The purpose of this study was to assess the accuracy of MR enteroclysis in patients with Crohn's disease recurrence after ileocolic resection and to establish an MR scoring sytem. MR enteroclysis and endoscopy were performed in 30 patients with suspected Crohn's disease recurrence after ileocolic resection. Findings were evaluated by three radiologists, using an MR score based on image quality, contrast enhancement, and mural and extramural bowel-wall changes: MR0 (no abnormal features), MR1 (minimal mucosal changes), MR2 (diffuse aphtoid ileitis, moderate recurrence), and MR3 (severe recurrence with trans- and extramural changes). The endoscopic Rutgeerts score defines changes at the ileum on a scale from I0 to I4. In 3/30 (10%) patients, evaluation was not possible. The mean overall image quality was rated as 1.7 (kappa 0.78). Comparing MR and Rutgeerts score, the mean observer agreement for the total score rating was 77.8% (kappa 0.67). When comparing only scores below or above MR2-the threshold indicative of the necessity of medical treatment-there was a total agreement of 95.1% (kappa 0.84). MR enteroclysis allows assessment of Crohn's disease recurrence after ileocolic resection. The MR score is reproducible and shows high agreement with the approved endoscopic Rutgeerts score.


Asunto(s)
Anastomosis Quirúrgica/efectos adversos , Enfermedad de Crohn/diagnóstico , Enfermedad de Crohn/etiología , Endoscopía Gastrointestinal/métodos , Imagen por Resonancia Magnética/métodos , Adulto , Anciano , Colon/cirugía , Enfermedad de Crohn/cirugía , Femenino , Humanos , Íleon/cirugía , Masculino , Persona de Mediana Edad , Recurrencia , Resultado del Tratamiento , Adulto Joven
7.
Radiology ; 245(3): 855-62, 2007 Dec.
Artículo en Inglés | MEDLINE | ID: mdl-17951347

RESUMEN

This ethics committee-approved pilot study was performed with informed consent. A Web-based service that was developed for automated measurement of joint space and automatic analysis of radiographs was tested prospectively. A total of 160 metacarpophalangeal joint spaces were measured in 20 patients (average age, 48 years; age range, 18-89 years; 16 women) suspected of having rheumatoid arthritis or osteoarthritis. The technical success rate was 93%. The smallest detectable difference in repeated automatic joint space width measurements varied from 0.08 to 0.31 mm, and the coefficient of variation was 2%-7%. Compared with the reference standard (interactive segmentation of the joint space widths) measurements, results were within a mean error of 0.19-0.40 mm. The proposed Web-based service enables reproducible joint space measurements to be obtained in metacarpophalangeal joints with moderate erosive and osteophytic disease.


Asunto(s)
Articulaciones de la Mano/diagnóstico por imagen , Articulaciones de la Mano/patología , Programas Informáticos , Adolescente , Adulto , Anciano , Anciano de 80 o más Años , Algoritmos , Femenino , Humanos , Masculino , Persona de Mediana Edad , Estudios Prospectivos , Radiografía
8.
Acad Radiol ; 14(10): 1179-88, 2007 Oct.
Artículo en Inglés | MEDLINE | ID: mdl-17889335

RESUMEN

RATIONALE AND OBJECTIVES: A method for the automatic detection and the visualization of erosions caused by rheumatoid arthritis is investigated. Erosion-enhanced viewing is a contribution to the computer-aided diagnosis of rheumatoid arthritis. It supports the clinician by providing the automatic marking of erosions and the visualization of any deviations from intact anatomy for a concise reviewing interface. MATERIALS AND METHODS: A generative appearance model is used to capture the variability of intact bone and erosions. The algorithm marks erosions on hand radiographs using this model, and visualizes these erosions with the help of the residual appearance error after fitting the model built from intact bone texture. The algorithm was evaluated on 17 hand radiographs. The standard of reference was an annotation of the erosions by a musculoskeletal radiologist. RESULTS: Detection results from the algorithm are reported for a set of 17 radiographs of moderately diseased hands. With a specificity of 84%, the detection of unequivocal erosions achieved a sensitivity of 85%. A receiver operating characteristic analysis yields an area under the curve of 0.92. The visualization provided a clear representation of the erosions as determined by two musculoskeletal radiologists. CONCLUSION: The automatic spotting of erosions provides promising results, and the visualization of the deviation from healthy anatomy aids clinicians in the evaluation of the erosions and in the reviewing of automatic detection results.


Asunto(s)
Artritis Reumatoide/diagnóstico , Diagnóstico por Computador , Humanos , Modelos Anatómicos
9.
IEEE Trans Pattern Anal Mach Intell ; 28(10): 1690-4, 2006 Oct.
Artículo en Inglés | MEDLINE | ID: mdl-16986548

RESUMEN

A fast AAM search algorithm based on canonical correlation analysis (CCA-AAM) is introduced. It efficiently models the dependency between texture residuals and model parameters during search. Experiments show that CCA-AAMs, while requiring similar implementation effort, consistently outperform standard search with regard to convergence speed by a factor of four.


Asunto(s)
Algoritmos , Inteligencia Artificial , Interpretación de Imagen Asistida por Computador/métodos , Almacenamiento y Recuperación de la Información/métodos , Reconocimiento de Normas Patrones Automatizadas/métodos , Simulación por Computador , Aumento de la Imagen/métodos , Modelos Teóricos , Estadística como Asunto
10.
Invest Radiol ; 39(6): 325-33, 2004 Jun.
Artículo en Inglés | MEDLINE | ID: mdl-15167098

RESUMEN

PURPOSE: To compare image quality of digital chest radiographs using 2 modes of gradation adjustment. METHODS: We compared image quality and visualization of anatomic landmarks of 50 chest radiographs after digital processing using a semiautomatic mode with a fixed gamma of 2.6 and an automatic mode with individual gamma adaptation. RESULTS: The mean gamma was significantly higher (P < 0.001) with the automatic mode (3.0 vs. 2.6, respectively). Patient constitution had no impact on the automatically adapted gamma for PA but showed a significant correlation (P < 0.001) for lateral images. For PA, there was a preference (P < 0.016) of the semiautomatic mode in heavier patients whereas no difference was seen in slim patients. For the lateral projection, there was a general preference (P = 0.001) of the automatic mode. CONCLUSION: For PA radiographs, the semiautomatic mode provides superior results for heavier patients without compromising the quality in slim patients. For lateral radiographs, the automatic mode provides generally superior results.


Asunto(s)
Intensificación de Imagen Radiográfica/normas , Radiografía Torácica/normas , Adulto , Anciano , Automatización , Femenino , Humanos , Masculino , Persona de Mediana Edad , Somatotipos
11.
Best Pract Res Clin Rheumatol ; 18(6): 783-811, 2004 Dec.
Artículo en Inglés | MEDLINE | ID: mdl-15501183

RESUMEN

The approach to the differential diagnosis of rheumatic diseases using conventional radiography is systematic and module-oriented, which, with respect to future developments, forms the basis for computer-assisted diagnosis (CAD). The indications follow consensus-based referral criteria and attempts should be made to raise the evidence level of the recommendations. Investigation techniques have been improved in the last few years with the use of digital radiography. New imaging technologies may be available in the future that will achieve at least the same quality of images, while exposing patients to a significantly lower radiation dose. The interpretation of radiographical signs could be enhanced through a correlation with other imaging modalities. Computer-assisted techniques with image processing tools for automated measurements, lesion detection and in the form of expert systems are under development. With conventional radiography embedded in CAD systems, promising options will be available to enhance the differential diagnosis of rheumatic diseases.


Asunto(s)
Artrografía/métodos , Enfermedades Reumáticas/diagnóstico por imagen , Artrografía/instrumentación , Diagnóstico Diferencial , Humanos , Procesamiento de Imagen Asistido por Computador , Articulaciones/patología , Enfermedades Reumáticas/clasificación , Reumatología/instrumentación , Reumatología/métodos
12.
Eur J Radiol ; 48(1): 61-70, 2003 Oct.
Artículo en Inglés | MEDLINE | ID: mdl-14511861

RESUMEN

In patients after chest trauma, imaging plays a key role for both, the primary diagnostic work-up, and the secondary assessment of potential treatment. Despite its well-known limitations, the anteroposterior chest radiograph remains the starting point of the imaging work-up. Adjunctive imaging with computed tomography, that recently is increasingly often performed on multidetector computed tomography units, adds essential information not readily available on the conventional radiograph. This allows better definition of trauma-associated thoracic injuries not only in acute traumatic aortic injury, but also in pulmonary, tracheobronchial, cardiac, diaphragmal, and thoracic skeletal injuries. This article reviews common radiographic findings in patients after chest trauma, shows typical imaging features resulting from thoracic injury, presents imaging algorithms, and recalls to the reader less common but clinically relevant entities encountered in patients after thoracic trauma.


Asunto(s)
Algoritmos , Traumatismos Torácicos/diagnóstico por imagen , Humanos , Tomografía Computarizada por Rayos X
13.
Inflamm Bowel Dis ; 16(2): 198-203, 2010 Feb.
Artículo en Inglés | MEDLINE | ID: mdl-19504611

RESUMEN

BACKGROUND: Ileocolonoscopy poses the gold standard in the evaluation of postoperative recurrence of Crohn's disease (CD) at the site of ileocolonic anastomosis. Magnetic resonance enteroclysis (MRE) on the other hand is a promising technique for small bowel imaging. The aim was to compare MRE and ileocolonoscopy for predicting clinical recurrence in CD patients who have undergone ileocolonic resection. METHODS: We included 29 patients in the study. The median time since index operation was 35 months and between ileocolonoscopy and MRE was 3 days. Patients were followed up for a maximum of 2 years unless clinical recurrence occurred earlier. Endoscopic findings were evaluated on a 5-grade scale (i0-i4), whereas MRE findings on the neoterminal ileum and anastomosis were assessed according to a previously validated 4-grade scale MR score (MR0-MR3). RESULTS: By classifying patients into subgroups of endoscopic severity of postoperative recurrence using as a threshold an endoscopic score of i3, we found that 10% of patients in the i0 to i2 group had a clinical recurrence during the 2-year follow-up period as compared to 52.6% of subjects with i3 to i4 (P = 0.043). The corresponding clinical exacerbation rates in the subgroups based on MRE severity assessment were 12.5% for MR0 to MR1 and 50% for MR2 to MR3 (P = 0.09). CONCLUSIONS: Our data suggest that colonoscopy and MR enteroclysis are of similar value to predict the risk of clinical recurrence in postoperative patients with Crohn's disease.


Asunto(s)
Colonoscopía , Enfermedad de Crohn/diagnóstico , Imagen por Resonancia Magnética/métodos , Adulto , Anciano , Colon/patología , Colon/cirugía , Enfermedad de Crohn/patología , Enfermedad de Crohn/cirugía , Femenino , Humanos , Estimación de Kaplan-Meier , Masculino , Persona de Mediana Edad , Valor Predictivo de las Pruebas , Recurrencia , Sensibilidad y Especificidad , Índice de Severidad de la Enfermedad , Factores de Tiempo , Adulto Joven
14.
Eur J Radiol ; 74(1): 236-40, 2010 Apr.
Artículo en Inglés | MEDLINE | ID: mdl-19285821

RESUMEN

In this study a fully automatic assessment of the knee alignment angles in full-limb radiographs was developed and compared to manual standard of reference measurements in a prospective manner. The data consisted of 28 knees which were gathered from total-leg radiographs of 15 patients (12 males and 3 females with a mean age of 29.4+/-6.9 years) consecutively. For statistical evaluation, a leave-one-out cross-validation was performed. The pattern recognition and consequently the fully automatic assessment were successful in all patients. The automatically measured angles highly correlated with the standard of reference (r=0.989). The mean absolute difference was 0.578 degrees (95% CI: 0.399-0.757 degrees ). 82% of the angles differed less than 1 degrees from the standard of reference, 46% differed less than 0.5 degrees and 31% differed less than 0.2 degrees . The automatic method showed a high agreement between repeated measurements (+0.515 degrees to -0.429 degrees ). The automatic assessment of alignment angles in full-limb radiographs were equal to the manual assessment. No measurement related user interaction was necessary to achieve results.


Asunto(s)
Deformidades Adquiridas de la Articulación/diagnóstico por imagen , Pierna/diagnóstico por imagen , Adulto , Automatización , Femenino , Humanos , Masculino , Estudios Prospectivos , Radiografía , Programas Informáticos
15.
Eur J Radiol ; 73(2): 224-9, 2010 Feb.
Artículo en Inglés | MEDLINE | ID: mdl-19097718

RESUMEN

PURPOSE: To demonstrate the value of multidetector computed tomography (MDCT) and magnetic resonance imaging (MRI) in the preoperative assessment of orbital tumors, and to present, particularly, CT and MR image data fusion for surgical planning and performance in computer-assisted navigated surgery of orbital tumors. MATERIALS AND METHODS: In this retrospective case series, 10 patients with orbital tumors and associated complaints underwent MDCT and MRI of the orbit. MDCT was performed at high resolution, with a bone window level setting in the axial plane. MRI was performed with an axial 3D T1-weighted (w) gradient-echo (GE) contrast-enhanced sequence, in addition to a standard MRI protocol. First, MDCT and MR images were used to diagnose tumorous lesions compared to histology as a standard of reference. Then, the image data sets from CT and 3D T1-w GE sequences were merged on a workstation to create CT-MR fusion images that were used for interventional planning and intraoperative image guidance. The intraoperative accuracy of the navigation unit was measured, defined as the deviation between the same landmark in the navigation image and the patient. Furthermore, the clinical preoperative status was compared to the patients' postoperative outcome. RESULTS: Radiological and histological diagnosis, which revealed 7 benign and 3 malignant tumors, were concordant in 7 of 10 cases (70%). The CT-MR fusion images supported the surgeon in the preoperative planning and improved the surgical performance. The mean intraoperative accuracy of the navigation unit was 1.35mm. Postoperatively, orbital complaints showed complete regression in 6 cases, were ameliorated notably in 3 cases, and remained unchanged in 1 case. CONCLUSION: CT and MRI are essential for the preoperative assessment of orbital tumors. CT-MR image data fusion is an accurate tool for planning the correct surgical procedure, and can improve surgical results in computer-assisted navigated surgery of orbital tumors.


Asunto(s)
Imagen por Resonancia Magnética/métodos , Neoplasias Orbitales/diagnóstico , Neoplasias Orbitales/cirugía , Cirugía Asistida por Computador/métodos , Tomografía Computarizada por Rayos X/métodos , Adulto , Anciano , Femenino , Humanos , Masculino , Persona de Mediana Edad , Reproducibilidad de los Resultados , Sensibilidad y Especificidad , Resultado del Tratamiento
16.
Eur J Radiol ; 73(2): 317-23, 2010 Feb.
Artículo en Inglés | MEDLINE | ID: mdl-19108971

RESUMEN

OBJECTIVE: The authors report imaging findings in a series of 16 patients with MCC, a rare tumour which is often managed primarily by a dermatologist. To our knowledge, no equivalent series of MCC has been described in the nuclear medicine literature. MATERIAL AND METHODS: In this IRB-approved retrospective noncomparative case series 16 patients with biopsy-proven Merkel cell carcinoma were included between January 1999 and October 2007. Twenty-nine whole body PET scans (18F-FDG n=24, 18F-FDOPA n=5) in 16 patients were retrospectively reviewed with regard to tracer uptake in six anatomical sites per patient. For 127/144 of FDG-PET evaluated regions and 68/144 of regions depicted by conventional imaging methods, a valid standard of reference could be obtained. A combined standard of reference was applied, which consisted of histopathology (lymphadenectomy or biopsy) or clinical or radiological follow-up for at least 12 months. RESULTS: the mean FDG uptake over the clinicopatholigical verified FDG avid areas was 4.7 SUV (1.5-9.9 SUV). The region based assessment of diagnostic value, in consideration of the standard of reference, resulted in a sensitivity of 85.7% and a specificity of 96.2% of FDG-PET (n=127) and in a combined sensitivity of 95.5% and a specificity of 89.1% for morphological imaging methods (n=68). Differences between methods did not reach statistical significance (p=1.00, p=0.18). CONCLUSIONS: FDG-PET is a highly useful whole body staging method of comparable value compared to conventional imaging methods with restricted field of view. The lessons learned from case series are discussed.


Asunto(s)
Carcinoma de Células de Merkel/diagnóstico , Fluorodesoxiglucosa F18 , Imagen por Resonancia Magnética/métodos , Tomografía de Emisión de Positrones/métodos , Neoplasias Cutáneas/diagnóstico , Tomografía Computarizada por Rayos X/métodos , Anciano , Anciano de 80 o más Años , Femenino , Humanos , Masculino , Persona de Mediana Edad , Radiofármacos , Reproducibilidad de los Resultados , Sensibilidad y Especificidad , Estadística como Asunto
17.
IEEE Trans Med Imaging ; 28(1): 151-64, 2009 Jan.
Artículo en Inglés | MEDLINE | ID: mdl-19116197

RESUMEN

Rheumatoid arthritis (RA) is a chronic disease that affects and potentially destroys the joints of the appendicular skeleton. The precise and reproducible quantification of the progression of joint space narrowing and the erosive bone destructions caused by RA is crucial during treatment and in imaging biomarkers in clinical trials. Current manual scoring methods exhibit high interreader variability, even after intensive training, and thus, impede the efficient monitoring of the disease. We propose a fully automatic quantitative assessment of the radiographic changes that result from RA, to increase the accuracy, reproducibility, and speed of image interpretation. Initial joint location estimates are obtained by local linear mappings based on texture features. Bone contours are delineated by active shape models comprised of statistical models of bone shape and local texture. These models are refined by snakes which increase the accuracy and allow for a fitting of pathological deviations from the training population. The method then measures joint space widths and detects erosions on the bone contour. Joint space widths are measured with a coefficient of variation of 2%-7% for repeated measurements and erosion detection exhibits an area under the receiver operating characteristic (ROC) curve of 0.89. Model landmarks serve as a reference system along the contour. These landmarks enable the definition of joint regions and more specific follow-up monitoring. The automatic quantification allows for a remote analysis, relevant for multicenter clinical trials, and reduces the workload of clinical experts since parts of the process can be managed by nonexpert personnel.


Asunto(s)
Artritis Reumatoide/diagnóstico por imagen , Artritis Reumatoide/patología , Articulaciones/patología , Reconocimiento de Normas Patrones Automatizadas/métodos , Interpretación de Imagen Radiográfica Asistida por Computador/métodos , Artrografía/métodos , Inteligencia Artificial , Huesos/diagnóstico por imagen , Huesos/patología , Progresión de la Enfermedad , Mano/patología , Humanos , Modelos Anatómicos , Interpretación de Imagen Radiográfica Asistida por Computador/normas , Estándares de Referencia , Sensibilidad y Especificidad , Técnica de Sustracción
18.
J Neuroimaging ; 19(3): 227-34, 2009 Jul.
Artículo en Inglés | MEDLINE | ID: mdl-18823292

RESUMEN

OBJECTIVE: We report our experience with radionuclide cisternography (RC) with 111In-diethylenthriamine penta-acetic acid (DTPA) using a computed tomography (CT) mounted hybrid gamma camera in patients with cerebrospinal liquor leakage. METHODS: SPECT/CT fusion imaging was performed in case of suspected tracer egress on planar or SPECT images in order to obtain a detailed correlation of the leakage site. RESULTS: Leakage was detected in all 3 patients. Using SPECT/CT, the extradural tracer accumulation could be correlated to an anatomical structure, which had not been possible by evaluation of the scintigraphic studies alone. CONCLUSION: Introducing SPECT/CT for radionuclide cisternography seems to be a valuable tool to facilitate the diagnosis of cerebrospinal liquor leakage.


Asunto(s)
Encéfalo/diagnóstico por imagen , Mielografía/métodos , Médula Espinal/diagnóstico por imagen , Tomografía Computarizada de Emisión de Fotón Único/métodos , Tomografía Computarizada por Rayos X/métodos , Líquido Cefalorraquídeo , Rinorrea de Líquido Cefalorraquídeo/diagnóstico por imagen , Femenino , Humanos , Radioisótopos de Indio , Hipotensión Intracraneal/diagnóstico por imagen , Masculino , Meningitis Bacterianas/diagnóstico por imagen , Persona de Mediana Edad , Ácido Pentético , Adulto Joven
19.
Eur J Radiol ; 70(1): 31-4, 2009 Apr.
Artículo en Inglés | MEDLINE | ID: mdl-18302979

RESUMEN

BACKGROUND AND PURPOSE: Today, functional endoscopic sinus surgery (FESS) is performed in most of the patients with sinonasal inflammatory disease. The postoperative imaging findings of FESS in multidetector computed tomography (MDCT) considerably differ from those of historic Caldwell-Luc (CL) maxillary sinus surgery which is an uncommon procedure today. Thus, the postoperative CL imaging findings may lead to diagnostic confusion and misinterpretation. Therefore, this study explicitly presents the MDCT findings of post-CL patients which have not been described previously. METHODS: Twenty-eight patients with clinically suspected sinusitis and documented history of CL-procedure underwent 16 row MDCT (MDCT Mx8000 IDT Philips) with multiplanar reconstructions of the paranasal sinuses in the axial plane. The following parameters were used: 140kV, 50mAs; 16mmx0.75mm detector collimation; 1mm reconstructed slice thickness; 0.5mm increment. The studies were reconstructed with a bone algorithm (W3000/L600; 1mm slice thickness) in axial plane and coronal plane (3mm slice thickness). The images were retrospectively evaluated for the presence of normal surgery-related and pathological findings. RESULTS: Surgery-related imaging characteristics presented as follows: an anterior and a medial bony wall defect and sclerosis and sinus wall thickening were observed in all 28/28 cases (100%). Collaps of the sinus cavity was seen in 26/28 cases (92.9%). Furthermore, inflammatory disease of the operated sinus(es) was found in 23/28 cases (82.1%): 14/28 patients (50%) had inflammatory mucosal thickening of the operated sinus(es) as well as of other sinonasal cavities and 9/28 patients (32.1%) had inflammatory mucosal thickening limited to the operated sinus(es). A postoperative mucocele was depicted in 3/28 cases (10.7%). 2/28 patients (7.1%) showed neither maxillary nor other mucosal swelling. CONCLUSION: MDCT with multiplanar reconstructions is a precise method to evaluate post-CL patients and helps to differentiate normal surgery-related findings, which may mimic pathology, from real pathological findings.


Asunto(s)
Drenaje/métodos , Endoscopía/métodos , Procedimientos Quirúrgicos Otorrinolaringológicos/métodos , Sinusitis/diagnóstico por imagen , Sinusitis/cirugía , Tomografía Computarizada por Rayos X/métodos , Adulto , Anciano , Anciano de 80 o más Años , Femenino , Humanos , Masculino , Persona de Mediana Edad , Estudios Retrospectivos , Resultado del Tratamiento
20.
Eur J Radiol ; 71(2): 211-6, 2009 Aug.
Artículo en Inglés | MEDLINE | ID: mdl-19457632

RESUMEN

In recent years, several computational image analysis methods to assess disease progression in rheumatic diseases were presented. This review article explains the basics of these methods as well as their potential application in rheumatic disease monitoring, it covers radiography, sonography as well as magnetic resonance imaging in quantitative analysis frameworks.


Asunto(s)
Algoritmos , Inteligencia Artificial , Aumento de la Imagen/métodos , Interpretación de Imagen Asistida por Computador/métodos , Reconocimiento de Normas Patrones Automatizadas/métodos , Enfermedades Reumáticas/diagnóstico , Humanos , Reproducibilidad de los Resultados , Sensibilidad y Especificidad
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA