Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 6 de 6
Filtrar
Más filtros

Bases de datos
Tipo de estudio
Tipo del documento
País de afiliación
Intervalo de año de publicación
1.
Angew Chem Int Ed Engl ; 53(24): 6155-8, 2014 Jun 10.
Artículo en Inglés | MEDLINE | ID: mdl-24764260

RESUMEN

A simple and inexpensive method is reported for the long-term stabilization of enzymes and other unstable reagents in premeasured quantities in water-soluble tablets (cast, not compressed) made with pullulan, a nonionic polysaccharide that forms an oxygen impermeable solid upon drying. The pullulan tablets dissolve in aqueous solutions in seconds, thereby facilitating the easy execution of bioassays at remote sites with no need for special reagent handling and liquid pipetting. This approach is modular in nature, thus allowing the creation of individual tablets for enzymes and their substrates. Proof-of-principle demonstrations include a Taq polymerase tablet for DNA amplification through PCR and a pesticide assay kit consisting of separate tablets for acetylcholinesterase and its chromogenic substrate, indoxyl acetate, both of which are highly unstable. The encapsulated reagents remain stable at room temperature for months, thus enabling the room-temperature shipping and storage of bioassay components.


Asunto(s)
Glucanos/química , Bioensayo , Carbohidratos , Comprimidos
2.
Lab Chip ; 17(5): 943-950, 2017 02 28.
Artículo en Inglés | MEDLINE | ID: mdl-28197602

RESUMEN

We describe a versatile and simple method to perform sequential reactions on paper analytical devices by stacking dry pullulan films on paper, where each film contains one or more reagents or acts as a delay layer. Exposing the films to an aqueous solution of the analyte leads to sequential dissolution of the films in a temporally controlled manner followed by diffusive mixing of the reagents, so that sequential reactions can be performed. The films can be easily arranged for lateral flow assays or for spot tests (reactions take place sequentially in the z-direction). We have tested the general feasibility of the approach using three different model systems to demonstrate different capabilities: 1) pH ramping from low to high and high to low to demonstrate timing control; 2) rapid ready-to-use two-step Simon's assays on paper for detection of drugs of abuse utilizing a 2-layer stack containing two different reagents to demonstrate the ability to perform assays in the z-direction; and 3) sequential cell lysing and colorimetric detection of an intracellular bacterial enzyme, to demonstrate the ability of the method to perform sample preparation and analysis in the form of a spot assay. Overall, these studies demonstrate the potential of stacked pullulan films as useful components to enable multi-step assays on simple paper-based devices.


Asunto(s)
Glucanos/química , Técnicas Analíticas Microfluídicas/instrumentación , Técnicas Analíticas Microfluídicas/métodos , Papel , Dietilaminas/análisis , Diseño de Equipo , Escherichia coli/aislamiento & purificación , Concentración de Iones de Hidrógeno , Indicadores y Reactivos/química
3.
Chem Sci ; 7(3): 2342-2346, 2016 Mar 01.
Artículo en Inglés | MEDLINE | ID: mdl-29997777

RESUMEN

Many biodetection systems employ labile enzymes and substrates that need special care, making it hard to routinely use them for point-of-care or field applications. In this work we provide a simple solution to this challenging problem through the creation of all-inclusive pullulan assay tablets. The proposed tablet system not only enhances the long-term stability of both enzymes and organic substrates, but also simplifies the assay procedure. The enhanced stability is attributed to two factors: the restriction of the molecular motion of proteins and impermeability to molecular oxygen afforded by the tables. These tablets dissolve rapidly upon addition to testing samples, making the test very easy to perform. Using the ATP-detecting luciferase-luciferin system as an example, we show that the tablet-based assay can achieve highly sensitive detection of ATP in biological samples and that the activity of the assay tablets remains unchanged for over a month at room temperature.

4.
Water Res ; 70: 360-9, 2015 Mar 01.
Artículo en Inglés | MEDLINE | ID: mdl-25546358

RESUMEN

In this paper we describe a combination of paper-based sensors and a novel smart-phone application for on-site quantification of colorimetric readouts as an ultra-low cost solution to monitoring water quality. The system utilizes a paper-based analytical device (µPAD) that produces a colorimetric signal that is dependent on the concentration of a specific target; a cell phone equipped with a camera for capturing images of two µPADs - one tested with a water sample and the other tested with clean water that is used as a control; and an on-site image processing app that uses a novel algorithm for quantifying color intensity and relating this to contaminant concentration. The cell phone app utilizes a pixel counting algorithm that performs with less bias and user subjectivity than the typically used lab-based software, ImageJ. The use of a test and control strip reduces bias from variations in ambient lighting, making it possible to acquire and process images on-site. The cell phone is also able to GPS tag the location of the test, and transmit results to a newly developed website, WaterMap.ca, that displays the quantitative results from the water samples on a map. We demonstrate our approach using a previously developed µPAD that detects the presence of organophosphate pesticides based on the inhibition of immobilized acetylcholinesterase by these contaminants. The objective of this paper is to highlight the importance and potential of developing and integrated monitoring system consisting of µPADs, cell-phones and a centralized web portal for low-cost monitoring environmental contaminants at a large-scale.


Asunto(s)
Monitoreo del Ambiente/instrumentación , Monitoreo del Ambiente/métodos , Papel , Teléfono Inteligente , Contaminantes Químicos del Agua/análisis , Calidad del Agua , Colorimetría/instrumentación , Procesamiento de Imagen Asistido por Computador , Técnicas Analíticas Microfluídicas , Organofosfatos/análisis , Plaguicidas/análisis
5.
ACS Appl Mater Interfaces ; 7(45): 25434-40, 2015 Nov 18.
Artículo en Inglés | MEDLINE | ID: mdl-26496157

RESUMEN

The utility of hydrophobic wax barriers in paper-based lateral flow and multiwell devices for containment of aqueous solvents was extended to organic solvents and challenging aqueous surfactant solutions by preparation of a three layer barrier, consisting of internal pullulan impregnated paper barriers surrounded by external wax barriers. When paper impregnated with pullulan solution dries, the polymer forms solvent blocking lenses in the paper structure. Lens formation was illustrated by forming pullulan lenses in glass capillaries. The lens shapes were less curved compared to the predictions of a model based upon minimizing surface area. For barriers on Whatman # 1 filter paper, the pullulan molecular weight must be greater than ∼70 kDa, the mass fraction of pullulan in the barrier zone must be at least 32%, and there are restrictions on the minimum width of the pullulan impregnated zone.

6.
Lab Chip ; 14(1): 229-36, 2014 Jan 07.
Artículo en Inglés | MEDLINE | ID: mdl-24195917

RESUMEN

Water soluble pullulan films were formatted into paper-based microfluidic devices, serving as a controlled time shutoff valve. The utility of the valve was demonstrated by a one-step, fully automatic implementation of a complex pesticide assay requiring timed, sequential exposure of an immobilized enzyme layer to separate liquid streams. Pullulan film dissolution and the capillary wicking of aqueous solutions through the device were measured and modeled providing valve design criteria. The films dissolve mainly by surface erosion, meaning the film thickness mainly controls the shutoff time. This method can also provide time-dependent sequential release of reagents without compromising the simplicity and low cost of paper-based devices.


Asunto(s)
Microfluídica/métodos , Papel , Automatización , Contaminación de Alimentos/análisis , Glucanos/química , Microfluídica/instrumentación , Plaguicidas/análisis , Polímeros/química , Viscosidad , Agua/química
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA