Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 7 de 7
Filtrar
1.
Med Microbiol Immunol ; 202(1): 77-86, 2013 Feb.
Artículo en Inglés | MEDLINE | ID: mdl-22706797

RESUMEN

Education and diagnostic tests capable of early detection represent our most effective means of preventing transmission of human immunodeficiency virus (HIV). The importance of early detection is underlined by studies demonstrating increased life expectancy following early initiation of antiviral treatment. The Elecsys(®) HIV combi PT assay is a fourth-generation antigen-antibody combination assay developed to allow earlier detection of seroconversion, and to have increased sensitivity and improved specificity. We aimed to determine how early the assay could detect infection compared with existing assays; whether all HIV variants could be detected; and the assay's specificity using samples from blood donors, routine specimens, and patients with potential cross-reacting factors. Samples were identified as positive by the Elecsys(®) assay 4.9 days after a positive polymerase chain reaction result (as determined by the panel supplier), which was earlier than the 5.3-7.1 days observed with comparators. The analytical sensitivity of the Elecsys(®) HIV combi PT assay for the HIV-1 p24 antigen was 1.05 IU/mL, which compares favorably with the comparator assays. In addition, the Elecsys(®) assay identified all screened HIV subtypes and displayed greater sensitivity to HIV-2 homologous antigen and antibodies to HIV-1 E and O and HIV-2 than the other assays. Overall, the specificity of the Elecsys(®) assay was 99.88 % using samples from blood donors and 99.81 % when analyzing unselected samples. Potential cross-reacting factors did not interfere with assay performance. The Elecsys(®) HIV combi PT assay is a sensitive and specific assay that has been granted the CE mark according to Directive 2009/886/EC.


Asunto(s)
Técnicas de Laboratorio Clínico/métodos , Pruebas Diagnósticas de Rutina/métodos , Anticuerpos Anti-VIH/sangre , Proteína p24 del Núcleo del VIH/sangre , Infecciones por VIH/diagnóstico , VIH-1/aislamiento & purificación , VIH-2/aislamiento & purificación , VIH-1/inmunología , VIH-2/inmunología , Humanos , Inmunoensayo/métodos , Sensibilidad y Especificidad
2.
J Clin Virol ; 112: 45-50, 2019 03.
Artículo en Inglés | MEDLINE | ID: mdl-30611626

RESUMEN

BACKGROUND: Fourth generation HIV assays, which detect both HIV p24 antigen and HIV antibodies are widely used in HIV screening. The combination of markers enables the fourth generation assays to shorten the window of detection, which is important in real-world testing scenarios. The Elecsys® HIV Duo assay is a fourth generation assay, which provides an overall result based on both the detection of the p24 antigen and HIV antibodies, and lists the sub-results for the antibody and antigen units. OBJECTIVES AND STUDY DESIGN: The performance of the Elecsys® HIV Duo assay was assessed at five international centres and compared with other available fourth generation assays. RESULTS: The specificity of the Elecsys® HIV Duo assay in 13,328 blood donor samples was 99.87% (95% confidence interval [CI] 99.80-99.93) and was 100% (95% CI 99.63-100) in 1000 routine diagnostic samples. Sensitivity was assessed in 139 seroconversion panels; the Elecsys® HIV Duo assay detected a greater number of positive samples/number of bleeds compared with other assays investigated. An individual analysis of those seroconversion panels also shows that the Elecsys® HIV Duo assay compared to other fourth generation assays detected HIV up to 2 days earlier than other assays. The Elecsys® HIV Duo assay also detected 125/130 'early seroconversion' samples assessed, which was greater than the number detected with comparator fourth generation assays. CONCLUSION: These results indicate that the Elecsys® HIV Duo assay is appropriate for use in the diagnosis of HIV and for screening of blood donations and is sensitive for the early detection of HIV.


Asunto(s)
Donantes de Sangre , Anticuerpos Anti-VIH/sangre , Proteína p24 del Núcleo del VIH/sangre , Infecciones por VIH/diagnóstico , Seropositividad para VIH/diagnóstico , Juego de Reactivos para Diagnóstico/normas , Diagnóstico Precoz , Infecciones por VIH/virología , Humanos , Internacionalidad , ARN Viral/sangre , Sensibilidad y Especificidad
3.
Clin Lab ; 52(9-10): 463-73, 2006.
Artículo en Inglés | MEDLINE | ID: mdl-17078473

RESUMEN

Fourth-generation screening assays which permit a simultaneous detection of human immunodeficiency virus (HIV) antigen and antibody reduce the diagnostic window on average by four days in comparison to third-generation antibody assays. Recently, the new automated Elecsys HIV combi was compared in a multicenter study to alternative fourth- and third-generation assays, p24 antigen test and HIV-1 RNA RT-PCR. A total of 104 serocon-version panels, samples of the acute phase of infection after seroconversion (n = 33), anti-HIV-1 positive specimens (n = 572) from patients in different stages of the disease, 535 subtyped samples from different geographical locations, including group M (subtypes A-J) and group O, anti-HIV-2 positive sera (n = 364), dilutions of cell culture supernatants (n = 60) infected with different HIV-1 subtypes, selected performance panels, 8406 unselected samples from blood donors originating from different blood transfusion centers, 3810 unselected sera from daily routine and from hospitalized patients, 9927 unselected samples from South Africa and 1943 potentially interfering samples were tested with the Elecsys HIV combi. Elecsys HIV combi showed a comparable sensitivity to HIV-1 Ag stand-alone assays for early detection of HIV infection in seroconversion panels. The mean time delay of Elecsys HIV combi (last negative sample + 1 day) in comparison to HIV-1 RT-PCR for 92 panels tested with both methods was 3.23 days. The diagnostic window was reduced with Elecsys HIV combi between 1.56 and 5.32 days in comparison to third-generation assays. The specificity of Elecsys HIV combi in blood donors was 99.80% after repeated testing. Our results show that a fourth-generation assay with improved specificity and sensitivity like the Elecsys HIV combi is suitable for blood donor screening due to its low number of false positives and since it detects HIV p24 antigen with a comparable sensitivity to single antigen assays.


Asunto(s)
Anticuerpos Anti-VIH/sangre , Proteína p24 del Núcleo del VIH/sangre , Infecciones por VIH/diagnóstico , VIH-1/aislamiento & purificación , VIH-2/aislamiento & purificación , Inmunoensayo , Diagnóstico Precoz , Humanos , ARN Viral/análisis , Reacción en Cadena de la Polimerasa de Transcriptasa Inversa , Sensibilidad y Especificidad
4.
Am J Med ; 99(4): 392-6, 1995 Oct.
Artículo en Inglés | MEDLINE | ID: mdl-7573095

RESUMEN

PURPOSE: An increased occurrence of thrombotic events has been described in patients exhibiting a lupus anticoagulant (LA). In patients with chronic, major vessel thromboembolic pulmonary hypertension, not only has there been a relatively high frequency of the LA, but also an unexpected association with heparin-related thrombocytopenia. This retrospective report emphasizes the frequency of this association. PATIENTS AND METHODS: We retrospectively reviewed the medical records of 216 patients admitted to the University of California, San Diego, Medical Center who were being considered for surgical correction of their chronic thromboembolic pulmonary hypertension. For each patient, the following information was sought: presence of an LA, variation in platelet numbers during the preoperative evaluation, and determination of whether an observed thrombocytopenia was related to heparin use. RESULTS: An LA was found in 23 of the 216 patients (10.6%). Of the remaining patients, sufficient platelet data for comparison were available for 68 patients. These 68 patients constituted the control group. Within the LA group, platelet counts during the preoperative evaluation declined to 51.6% +/- 16.7% of baseline counts, a highly significant difference (P < 0.0001) compared with the non-LA control group, who underwent a comparable evaluation with similar heparin exposure. In addition, heparin-associated thrombocytopenia developed in 13 of the 23 LA patients (56.5%) and in none of the control patients. Heparin-induced arterial thrombosis was implicated as the cause of a myocardial infarction in 1 of the patients with heparin-associated thrombocytopenia. CONCLUSIONS: In patients with chronic thromboembolic pulmonary hypertension, a high incidence of the LA and an accompanying association with heparin-related thrombocytopenia have been observed. Although further prospective studies of this relationship are needed, physicians should be alert to the possibility of thrombocytopenia when using heparin for patients exhibiting an LA.


Asunto(s)
Anticoagulantes/efectos adversos , Heparina/efectos adversos , Hipertensión Pulmonar/sangre , Inhibidor de Coagulación del Lupus/sangre , Trombocitopenia/inducido químicamente , Tromboembolia/sangre , Tromboembolia/tratamiento farmacológico , Anticoagulantes/uso terapéutico , Estudios de Casos y Controles , Enfermedad Crónica , Heparina/uso terapéutico , Humanos , Hipertensión Pulmonar/etiología , Registros Médicos , Recuento de Plaquetas/efectos de los fármacos , Estudios Retrospectivos , Tromboembolia/complicaciones
5.
Int J Hematol ; 72(3): 325-8, 2000 Oct.
Artículo en Inglés | MEDLINE | ID: mdl-11185988

RESUMEN

Aplastic anemia has been reported to occur after viral hepatitis of unknown etiology. Recently, TT virus (TTV), a novel DNA virus, was identified in a Japanese patient with posttransfusion non-A-E hepatitis. The prevalence of TTV infection was investigated among blood donors and patients with aplastic anemia in Thailand. Of 99 blood samples from blood donors, 37 tested positive for TTV DNA via semi-nested polymerase chain reaction (PCR) using TTV-specific primers. Seventeen percent of samples from blood donors younger than 20 were positive for TTV DNA, whereas 48% from donors older than 20 were positive. The high prevalence of TTV infection in Thailand is comparable to that reported in China (28%), Mongolia (43%), and Egypt (29%). Forty-two percent of newly diagnosed aplastic anemia patients tested also had TTV DNA in blood. The detection rate of TTV DNA in aplastic anemia patients does not differ significantly from rates in normal blood donors. Our present data thus argue against the role of this novel hepatitis-associated virus in the pathogenesis of aplastic anemia in Thailand. However, larger epidemiological studies may be needed to further evaluate their association.


Asunto(s)
Anemia Aplásica/complicaciones , Donantes de Sangre , Infecciones por Virus ADN/etiología , Torque teno virus , Adulto , Anemia Aplásica/epidemiología , Infecciones por Virus ADN/epidemiología , Femenino , Humanos , Masculino , Prevalencia , Tailandia/epidemiología
7.
Blood ; 83(10): 2878-92, 1994 May 15.
Artículo en Inglés | MEDLINE | ID: mdl-8180383

RESUMEN

We present functional and binding data relevant to the reported roles for prothrombin and beta 2-glycoprotein I (beta 2GPI) in the expression of lupus anticoagulant activity. In a purified system containing human prothrombin, Xa, Va, and a rate-limiting concentration of phosphatidylserine (PS)/phosphatidylcholine (PC) vesicles, the preliminary incubation of vesicles with protein A separated IgG preparations from 10 lupus anticoagulant plasmas, calcium, and prothrombin enhanced the inhibitory effect of all IgG preparations upon thrombin generation. Experiments in a purified factor X activation system provided supporting data that a similar preliminary incubation with prothrombin enhanced the inhibitory effect of many of the IgG preparations upon factor X activation. However, we could not obtain unequivocal evidence that prothrombin was an obligatory cofactor for lupus anticoagulant IgG to inhibit procoagulant phospholipid function, because lupus anticoagulant IgG separated by protein A chromatography contained traces of prothrombin. The binding of many IgG preparations to immobilized PS was enhanced by prothrombin when calcium ions were present. beta 2GPI enhanced binding of many of the IgG preparations to immobilized PS both in the presence and absence of calcium, yet beta 2GPI failed to enhance the ability of the IgG preparations to inhibit phospholipid function in purified prothrombin and factor X assays. Moreover, the IgG preparations prolonged the dilute Russell's viper venom time (dRVVT) of beta 2GPI-depleted normal plasma. Nine of 10 IgG preparations bound to prothrombin on Western blots in the absence of calcium and phospholipid, whereas no preparation bound to beta 2GPI. Passage of five citrated lupus anticoagulant plasmas through a prothrombin affinity column in the absence of added calcium and phospholipid removed most of the activity prolonging the dRVVT of normal plasma, and IgG in the pass-through plasma no longer bound to PS in the presence of prothrombin and calcium ions. IgG in prothrombin column eluates had strikingly enhanced specific lupus anticoagulant activity and also specific PS binding activity in the presence of prothrombin and calcium ions. Thus, lupus anticoagulant plasmas were shown to contain IgG binding to prothrombin, in the absence of calcium ions and phospholipid, which could also, in the presence of calcium ions and prothrombin, bind to PS and express lupus anticoagulant activity.


Asunto(s)
Glicoproteínas/fisiología , Inhibidor de Coagulación del Lupus/fisiología , Protrombina/fisiología , Adulto , Animales , Coagulación Sanguínea , Calcio/fisiología , Factor X/metabolismo , Femenino , Humanos , Inmunoglobulina G/fisiología , Masculino , Persona de Mediana Edad , Fosfolípidos/fisiología , Conejos , Trombina/biosíntesis , beta 2 Glicoproteína I
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA