Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 45
Filtrar
1.
Sensors (Basel) ; 22(18)2022 Sep 19.
Artículo en Inglés | MEDLINE | ID: mdl-36146436

RESUMEN

Fouling control coatings (FCCs) are used to prevent the accumulation of marine biofouling on, e.g., ship hulls, which causes increased fuel consumption and the global spread of non-indigenous species. The standards for performance evaluations of FCCs rely on visual inspections, which induce a degree of subjectivity. The use of RGB images for objective evaluations has already received interest from several authors, but the limited acquired information restricts detailed analyses class-wise. This study demonstrates that hyperspectral imaging (HSI) expands the specificity of biofouling assessments of FCCs by capturing distinguishing spectral features. We developed a staring-type hyperspectral imager using a liquid crystal tunable filter as the wavelength selective element. A novel light-emitting diode illumination system with high and uniform irradiance was designed to compensate for the low-filter transmittance. A spectral library was created from reflectance-calibrated optical signatures of representative biofouling species and coated panels. We trained a neural network on the annotated library to assign a class to each pixel. The model was evaluated on an artificially generated target, and global accuracy of 95% was estimated. The classifier was tested on coated panels (exposed at the CoaST Maritime Test Centre) with visible intergrown biofouling. The segmentation results were used to determine the coverage percentage per class. Although a detailed taxonomic description might be complex due to spectral similarities among groups, these results demonstrate the feasibility of HSI for repeatable and quantifiable biofouling detection on coated surfaces.


Asunto(s)
Incrustaciones Biológicas , Incrustaciones Biológicas/prevención & control , Navíos
2.
Opt Express ; 28(4): 5758-5767, 2020 Feb 17.
Artículo en Inglés | MEDLINE | ID: mdl-32121791

RESUMEN

In laser lighting, a major benefit over other lighting techniques is the possibility to achieve very high luminous exitance. Focusing the exciting laser to a very small spot size on the phosphor, however, does not necessarily provide a very small emitting area for the white light. In this study we investigate experimentally and numerically the relationship between the white light spot size and the incident blue laser spot size. We show that the specific phosphor material properties have significant impact on this relationship and on the achievable minimum spot size. This constitutes a limitation on the minimum spot size achievable in laser lighting and has important implications in applications.

3.
Opt Lett ; 43(3): 399-402, 2018 Feb 01.
Artículo en Inglés | MEDLINE | ID: mdl-29400869

RESUMEN

Diffuse optical tomography (DOT) is a reliable and widespread technique for monitoring qualitative changes in absorption inside highly scattering media. It has been shown, however, that acousto-optic (AO) imaging can provide significantly more qualitative information without the need for inversion algorithms due to the spatial resolution afforded by ultrasound probing. In this Letter, we show how, by using multiple-wavelength AO imaging, it is also possible to perform quantitative measurements of absorber concentration inside scattering media.

4.
Opt Express ; 24(19): 22135-43, 2016 Sep 19.
Artículo en Inglés | MEDLINE | ID: mdl-27661948

RESUMEN

We report on the design, development and investigation of an optical system based on UV light emitting diode (LED) excitation at 340 nm for time-resolved fluorescence detection of immunoassays. The system was tested to measure cardiac marker Troponin I with a concentration of 200 ng/L in immunoassay. The signal-to-noise ratio was comparable to state-of-the-art Xenon flash lamp based unit with equal excitation energy and without overdriving the LED. We performed a comparative study of the flash lamp and the LED based system and discussed temporal, spatial, and spectral features of the LED excitation for time-resolved fluorimetry. Optimization of the suggested key parameters of the LED promises significant increase of the signal-to-noise ratio and hence of the sensitivity of immunoassay systems.

5.
Opt Lett ; 41(18): 4154-7, 2016 Sep 15.
Artículo en Inglés | MEDLINE | ID: mdl-27628345

RESUMEN

A 480 mW green tunable diode laser system is demonstrated for the first time to our knowledge. The laser system is based on a GaN broad-area diode laser and Littrow external-cavity feedback. The green laser system is operated in two modes by switching the polarization direction of the laser beam incident on the grating. When the laser beam is p-polarized, an output power of 50 mW with a tunable range of 9.2 nm is achieved. When the laser beam is s-polarized, an output power of 480 mW with a tunable range of 2.1 nm is obtained. This constitutes the highest output power from a tunable green diode laser system.

6.
Neuropsychobiology ; 74(4): 193-201, 2016.
Artículo en Inglés | MEDLINE | ID: mdl-28637044

RESUMEN

BACKGROUND AND AIM: Improvement in patients admitted to inpatient wards with severe depression is slow, and such patients are often discharged with residual symptoms which put them at risk for relapse. New treatments that can speed up recovery are highly desired. This naturalistic follow-up study in a specialized affective disorders unit investigated the impact of daylight on the length of hospital stay and improvement of depression. METHODS: For a period of 1 year, we collected data on sociodemographics, length of stay, vitamin D, and depression severity for patients in an inpatient affective disorders unit. The ward is located with one facade that faces southeast (SE); the opposite one faces northwest (NW) and receives far less light and no direct sunlight during winter. RESULTS: SE-facing rooms received far more daylight than NW-facing rooms. The length of stay was significantly lower in the SE rooms, i.e., 29.2 (±26.8) versus 58.8 (±42.0) days in the NW rooms (p = 0.01). There was a statistically nonsignificant greater reduction of 52.2% in depression severity for the patients staying in the SE rooms compared to 42.2% in the NW rooms, which may nevertheless be clinically relevant. CONCLUSION: Due to the study design, no causality for the observed difference in length of stay can be given, but the results support findings in previous studies of the importance of architectural orientation providing natural daylight as a factor for improvement.

7.
J Opt Soc Am A Opt Image Sci Vis ; 33(1): 141-8, 2016 Jan 01.
Artículo en Inglés | MEDLINE | ID: mdl-26831595

RESUMEN

In the present study we provide empirical evidence and demonstrate statistically that white illumination settings can affect the human ability to identify veins in the inner hand vasculature. A special light-emitting diode lamp with high color rendering index (CRI 84-95) was developed and the effect of correlated color temperature was evaluated, in the range between 2600 and 5700 K at an illuminance of 40±9 lx on the ability of adult humans to identify veins. It is shown that the ability to identify veins can, on average, be increased up to 24% when white illumination settings that do not resemble incandescent light are applied. The illuminance reported together with the effect of white illumination settings on direct visual perception of biosamples are relevant for clinical investigations during the night.


Asunto(s)
Temperatura , Venas , Percepción Visual , Adolescente , Adulto , Factores de Edad , Anciano , Color , Femenino , Humanos , Iluminación , Masculino , Persona de Mediana Edad , Neovascularización Fisiológica , Factores Sexuales , Venas/fisiología , Percepción Visual/efectos de la radiación , Adulto Joven
8.
Appl Opt ; 55(9): 2263-9, 2016 03 20.
Artículo en Inglés | MEDLINE | ID: mdl-27140561

RESUMEN

In this paper we discuss how different feedback gratings affect the tuning range and the output power of external feedback diode laser systems. A tunable high-power narrow-spectrum external-cavity diode laser system around 455 nm is investigated. The laser system is based on a high-power GaN diode laser in a Littrow external-cavity. Both a holographic diffraction grating and a ruled diffraction grating are used as feedback elements in the external cavity. The output power, spectral bandwidth, and tunable range of the external cavity diode laser system are measured and compared with the two gratings at different injected currents. When the holographic grating is used, the laser system can be tuned over a range of 1.4 nm with an output power around 530 mW. When the ruled grating is used, the laser system can be tuned over a range of 6.0 nm with an output power around 80 mW. The results can be used as a guide for selecting gratings for external-cavity diode lasers for different requirements.

9.
Ann Med ; 56(1): 2297273, 2024 12.
Artículo en Inglés | MEDLINE | ID: mdl-38316028

RESUMEN

Introduction: This study investigated the health effects of two different architectural glass types: A two-layered low-iron high transmittance glass and a three-layered low energy glass with lower transmittance. The study investigated how these glass types affected daylight conditions in 72 residential apartments, as well as health and satisfaction of the residents.Methods: The study installed high transmittance glass (light transmittance LT:0.82) in 36 apartments and low transmittance (LT:0.74) in 36 identical apartments. The study then analyzed the light transmittance of each glass type in the laboratory and analyzed the indoor environmental quality (IEQ) in eight representative apartments before and after renovation. Self-reported questionnaires were handed out and collected before and after renovation.Results: The results showed that the glass types differed significantly in measured daylight transmittance. The two-layered high transmittance glass transmitted 15% more visual light (380-750 nm) and 20% more light in the spectral range (460-480 nm), stimulating ipRGCs and circadian rhythm, when compared to three-layered low energy glass. In addition, significant differences were observed in the UV-B spectrum (280-315 nm). While two-layered high transmittance glass transmitted UV-B, three-layered low transmittance glass did not. During the 12-month study period, residents in apartments with three-layered low energy glass reported more difficulties sleeping (p = 0.05), higher satisfaction with daylight (p = 0.03) and higher satisfaction with ventilation (p = 0.04). Residents in apartments with three-layered low energy glass experienced fewer days with too cold indoor temperatures (p = 0.02), compared to residents with two-layered low-iron glass. The results of energy consumption for heating showed that two-layered low-iron glass reduced the energy consumption by 11.0%, while three-layered low energy glass reduced the energy consumption by 9.4%, compared to the year prior to renovation.Conclusion: The results contribute to a discussion about potential energy savings on one hand and potential non-energy benefits, such as daylight quality, overall health, and total economy/life cycle assessment of the built environment on the other hand. The results suggest further research performed in randomized large-scale studies.


Asunto(s)
Ritmo Circadiano , Sueño , Humanos , Autoinforme , Encuestas y Cuestionarios , Hierro
10.
Sci Rep ; 14(1): 2147, 2024 01 25.
Artículo en Inglés | MEDLINE | ID: mdl-38273009

RESUMEN

Alzheimer's disease (AD) is associated with electrophysiological changes in the brain. Pre-clinical and early clinical trials have shown promising results for the possible therapy of AD with 40 Hz neurostimulation. The most notable findings used stroboscopic flicker, but this technique poses an inherent barrier for human applications due to its visible flickering and resulting high level of perceived discomfort. Therefore, alternative options should be investigated for entraining 40 Hz brain activity with light sources that appear less flickering. Previously, chromatic flicker based on red, green, and blue (RGB) have been studied in the context of brain-computer interfaces, but this is an incomplete representation of the colours in the visual spectrum. This study introduces a new kind of heterochromatic flicker based on spectral combinations of blue, cyan, green, lime, amber, and red (BCGLAR). These combinations are investigated by the steady-state visually evoked potential (SSVEP) response from the flicker with an aim of optimising the choice of 40 Hz light stimulation with spectrally similar colour combinations in BCGLAR space. Thirty healthy young volunteers were stimulated with heterochromatic flicker in an electroencephalography experiment with randomised complete block design. Responses were quantified as the 40 Hz signal-to-noise ratio and analysed using mixed linear models. The size of the SSVEP response to heterochromatic flicker is dependent on colour combinations and influenced by both visual and non-visual effects. The amber-red flicker combination evoked the highest SSVEP, and combinations that included blue and/or red consistently evoked higher SSVEP than combinations only with mid-spectrum colours. Including a colour from either extreme of the visual spectrum (blue and/or red) in at least one of the dyadic phases appears to be more important than choosing pairs of colours that are far from each other on the visual spectrum. Spectrally adjacent colour pairs appear less flickering to the perceiver, and thus the results motivate investigations into the limits for how alike the two phases can be and still evoke a 40 Hz response. Specifically, combining a colour on either extreme of the visual spectrum with another proximal colour might provide the best trade-off between flickering sensation and SSVEP magnitude.


Asunto(s)
Ámbar , Interfaces Cerebro-Computador , Humanos , Estimulación Luminosa/métodos , Potenciales Evocados Visuales , Electroencefalografía/métodos , Encéfalo
11.
Ann Med ; 56(1): 2354852, 2024 May 11.
Artículo en Inglés | MEDLINE | ID: mdl-38767238

RESUMEN

BACKGROUND: Major depressive disorder (MDD) is a debilitating condition that affects more than 300 million people worldwide. Current treatments are based on a trial-and-error approach, and reliable biomarkers are needed for more informed and personalized treatment solutions. One of the potential biomarkers, gamma-frequency (30-80 Hz) brainwaves, are hypothesized to originate from the excitatory-inhibitory interaction between the pyramidal cells and interneurons. The imbalance between this interaction is described as a crucial pathological mechanism in neuropsychiatric conditions, including MDD, and the modulation of this pathological interaction has been investigated as a potential target. Previous studies attempted to induce gamma activity in the brain using rhythmic light and sound stimuli (GENUS - Gamma Entrainment Using Sensory stimuli) that resulted in neuroprotective effects in Alzheimer's disease (AD) patients and animal models. Here, we investigate the antidepressant, cognitive, and electrophysiological effects of the novel light therapy approach using 40 Hz masked flickering light for patients diagnosed with MDD. METHODS AND DESIGN: Sixty patients with a current diagnosis of a major depressive episode will be enrolled in a randomized, double-blinded, placebo-controlled trial. The active treatment group will receive 40 Hz masked flickering light stimulation while the control group will receive continuous light matched in color temperature and brightness. Patients in both groups will get daily light treatment in their own homes and will attend four follow-up visits to assess the symptoms of depression, including depression severity measured by Hamilton Depression Rating Scale (HAM-D17), cognitive function, quality of life and sleep, and electroencephalographic changes. The primary endpoint is the mean change from baseline to week 6 in depression severity (HAM-D6 subscale) between the groups.


Asunto(s)
Trastorno Depresivo Mayor , Humanos , Trastorno Depresivo Mayor/terapia , Método Doble Ciego , Masculino , Femenino , Adulto , Persona de Mediana Edad , Fototerapia/métodos , Resultado del Tratamiento , Adulto Joven , Ritmo Gamma/fisiología , Anciano , Electroencefalografía/métodos , Adolescente
12.
Opt Express ; 21(5): 6076-81, 2013 Mar 11.
Artículo en Inglés | MEDLINE | ID: mdl-23482175

RESUMEN

We report the realization of a tapered diode laser operated in a coupled ring cavity that significantly improves the coherence properties of the tapered laser and efficiently generates tunable light at the second harmonic frequency. The tapered diode laser is tunable with single-frequency output in the broad wavelength range from 1049 nm to 1093 nm and the beam propagation factor is improved from M(2) = 2.8 to below 1.1. The laser frequency is automatically locked to the cavity resonance frequency using optical feedback. Furthermore, we show that this adaptive external cavity approach leads to efficient frequency doubling. More than 500 mW green output power is obtained by placing a periodically poled LiNbO(3) crystal in the external cavity. The single frequency green output from the laser system is tunable in the 530 nm to 533 nm range limited by the LiNbO(3) crystal. The optical to optical conversion efficiency exceeds 30%.

13.
Sci Rep ; 13(1): 4807, 2023 Mar 23.
Artículo en Inglés | MEDLINE | ID: mdl-36959390

RESUMEN

Spatially resolved in situ monitoring of plankton can provide insights on the impacts of climate change on aquatic ecosystems due to their vital role in the biological carbon pump. However, high-resolution underwater imaging is technically complex and restricted to small close-range volumes with current techniques. Here, we report a novel inelastic scanning confocal light detection and ranging (LiDAR) system for remote underwater volumetric imaging of fluorescent objects. A continuous wave excitation beam is combined with a pinhole in a conjugated detection plane to reject out-of-focus scattering and accomplish near-diffraction limited probe volumes. The combination of bi-directional scanning with remote focusing enables the acquisition of three-dimensional data. We experimentally determine the point spread and axial weighting functions, and demonstrate selective volumetric imaging of obstructed layers through spatial filtering. Finally, we spatially resolve in vivo autofluorescence from sub-millimeter Acocyclops royi copepods to demonstrate the applicability of our novel instrument in non-intrusive morphological and spectroscopic studies of aquatic fauna. The proposed system constitutes a unique tool e.g. for profiling chlorophyll distributions and for quantitative studies of zooplankton with reduced interference from intervening scatterers in the water column that degrade the the performance of conventional imaging systems currently in place.

14.
Clocks Sleep ; 5(4): 806-830, 2023 Dec 15.
Artículo en Inglés | MEDLINE | ID: mdl-38131751

RESUMEN

The purpose of this paper is to investigate the impact of circadian lighting-induced melatonin suppression on patients with psychiatric and neurological disorders in hospital wards by using an ad-hoc metrology framework and the subsequent metrics formalized by the CIE in 2018. A measurement scheme was conducted in hospital ward rooms in the Department of Neurology, Zealand University Hospital, at Roskilde in Denmark, to evaluate the photometric and colorimetric characteristics of the lighting system, as well as its influence on the circadian rhythm of the occupants. The measurement scheme included point measurements and data logging, using a spectrophotometer mounted on a tripod with adjustable height to assess the newly installed circadian lighting system. The measured spectra were uploaded to the Luox platform to calculate illuminance, CCT, MEDI, etc., in accordance with the CIE S026 standard. Furthermore, the MLIT based on MEDI data logging results was calculated. In addition to CIE S026, we have investigated the usefulness of melatonin suppression models for the assessment of circadian performance regarding measured light. From the results, the lighting conditions in the patient room for both minimal and abundant daylight access were evaluated and compared; we found that access to daylight is essential for both illumination and circadian entrainment. It can be concluded that the measurement scheme, together with the use of the Luox platform and Canva template, is suitable for the accurate and satisfactory measurement of integrative lighting that aligns with CIE requirements and recommendations.

15.
J Alzheimers Dis ; 92(2): 653-665, 2023.
Artículo en Inglés | MEDLINE | ID: mdl-36776073

RESUMEN

BACKGROUND: Recent studies suggested induction of 40 Hz neural activity as a potential treatment for Alzheimer's disease (AD). However, prolonged exposure to flickering light raises adherence and safety concerns, encouraging investigation of tolerable light stimulation protocols. OBJECTIVE: To investigate the safety, feasibility, and exploratory measures of efficacy. METHODS: This two-stage randomized placebo-controlled double-blinded clinical trial, recruited first cognitive healthy participants (n = 3/2 active/placebo), and subsequently patients with mild-to-moderate AD (n = 5/6, active/placebo). Participants were randomized 1:1 to receive either active intervention with 40 Hz Invisible Spectral Flicker (ISF) or placebo intervention with color and intensity matched non-flickering white light. RESULTS: Few and mild adverse events were observed. Adherence was above 86.1% of intended treatment days, with participants remaining in front of the device for >51.3 min (60 max) and directed gaze >34.9 min. Secondary outcomes of cognition indicate a tendency towards improvement in the active group compared to placebo (mean: -2.6/1.5, SD: 6.58/6.53, active/placebo) at week 6. Changes in hippocampal and ventricular volume also showed no tendency of improvement in the active group at week 6 compared to placebo. At week 12, a potential delayed effect of the intervention was seen on the volume of the hippocampus in the active group compared to placebo (mean: 0.34/-2.03, SD: 3.26/1.18, active/placebo), and the ventricular volume active group (mean: -0.36/2.50, SD: 1.89/2.05, active/placebo), compared to placebo. CONCLUSION: Treatment with 40 Hz ISF offers no significant safety or adherence concerns. Potential impact on secondary outcomes must be tested in larger scale clinical trials.


Asunto(s)
Enfermedad de Alzheimer , Fototerapia , Anciano , Femenino , Humanos , Masculino , Persona de Mediana Edad , Enfermedad de Alzheimer/clasificación , Enfermedad de Alzheimer/diagnóstico , Enfermedad de Alzheimer/terapia , Método Doble Ciego , Estudios de Factibilidad , Fototerapia/efectos adversos , Fototerapia/métodos , Proyectos Piloto , Resultado del Tratamiento
16.
Front Aging Neurosci ; 15: 1250626, 2023.
Artículo en Inglés | MEDLINE | ID: mdl-37901795

RESUMEN

Introduction: With no cure or effective treatment, the prevalence of patients with Alzheimer's disease (AD) is expected to intensify, thereby increasing the social and financial burden on society. Light-based 40 Hz brain stimulation is considered a novel treatment strategy for patients with AD that may alleviate some of this burden. The clinical trial ALZLIGHT will utilize a novel Light Therapy System (LTS). The LTS uses Invisible Spectral Flicker for non-invasive induction of 40 Hz neural activity. This protocol describes a trial evaluating the efficacy and safety of a light-based 40 Hz brain stimulation in patients with mild-to-moderate AD. Methods: 62 patients with mild-to-moderate AD will participate in a randomized, double-blinded, placebo-controlled, parallel-group, and single-center trial. The participants will partake in an enrollment period of 1 month, an intervention period of 6 months, and a 1.5-month post-interventional follow-up period. Prior to the baseline measurement (week 0), the patients will be randomized to either active or placebo intervention from baseline (week 0) to post-intervention follow-up (week 26). Discussion: This protocol describes a randomized, double-blinded, placebo-controlled clinical trial that may increase the understanding of the effect of gamma oscillations in the human brain and how it could be utilized as a novel and important tool for the treatment of AD. The effect is measured through a large, multidisciplinary assessment battery.Clinical trial registration:www.ClinicalTrials.gov, (NCT05260177). Registered on March 2, 2022.

17.
Opt Lett ; 37(18): 3753-5, 2012 Sep 15.
Artículo en Inglés | MEDLINE | ID: mdl-23041848

RESUMEN

In order to increase the power of visible diode laser systems in an efficient manner, we propose spectral beam combining with subsequent sum-frequency generation. We show that this approach, in comparison with second harmonic generation of single emitters, can enhance the available power significantly. By combining two distributed Bragg reflector tapered diode lasers we achieve a 2.5-3.2 fold increase in power and a maximum of 3.9 W of diffraction-limited green light. At this power level, green diode laser systems have a high application potential, e.g., within the biomedical field. Our concept can be expanded combining multiple diode lasers to increase the power even further.

18.
Foods ; 11(5)2022 Mar 01.
Artículo en Inglés | MEDLINE | ID: mdl-35267358

RESUMEN

Since few foods are naturally rich in vitamin D, novel food products with a high content of vitamin D are needed to decrease the prevalence of vitamin D deficiency. Pork cracklings are Danish snacks with high contents of protein and fat. They are consumed mostly during wintertime when sun exposure cannot fulfil human needs for vitamin D3. Pork cracklings were produced in an industrially friendly manner from UVB LED illuminated pork rind, using a combination of sous vide (85 °C, 60 min) and roasting in the oven (200 °C, 20 min). Thermal processing resulted in a significant loss of vitamin D3 (>90%). Thus, the process was optimized by the UVB exposure of pork cracklings, i.e., after thermal processing. The produced pork cracklings had a vitamin D3 level of ~10 µg/100 g, with a possibility of tailoring its final content. Furthermore, the fat content at 15−20% was a reduction of 50% compared to marketed products in 2021. No significant difference was found in the content of vitamin D3 during 31 days of storage in the air. A consumer preference test (n = 53) indicated that >80% of participants liked the product and saw its potential as a new food source of vitamin D3.

19.
J Alzheimers Dis ; 88(1): 335-344, 2022.
Artículo en Inglés | MEDLINE | ID: mdl-35570490

RESUMEN

BACKGROUND: Exposure to 40 Hz stroboscopic light, for one hour a day, has previously been published as a potential treatment option for Alzheimer's disease in animal models. However, exposure for an hour a day to 40 Hz stroboscopic light can be strenuous and examining other types of 40 Hz inducing stimuli is paramount if chronic treatment is wanted. OBJECTIVE: A core assumption behind ensuring a therapeutic outcome is that the visual stimuli can induce 40 Hz gamma entrainment. Here, we examine whether a specific visual stimulus, 40 Hz invisible spectral flicker (ISF), can induce gamma entrainment and how it differs from both continuous light (CON) and 40 Hz stroboscopic light (STROBE). METHODS: The study included non-simultaneous EEG-fMRI neuroimaging of 13 young healthy volunteers during light exposure. Each light condition (i.e., CON, ISF, or STROBE) was active for 30 seconds followed immediately by the next. RESULTS: Entrainment of 40 Hz neural activity were significantly higher signal-to-noise ratio during exposure to ISF (mean: 3.03, 95% CI 2.07 to 3.99) and STROBE (mean: 12.04, 95% CI 10.18 to 13.87) compared to CON. Additionally STROBE had a higher entrainment than ISF (mean: 9.01, 95% CI 7.16 to 12.14). CONCLUSION: This study presents a novel method of 40 Hz entrainment using ISF. This enables the possibility of future randomized placebo-controlled clinical trials with acceptable double blinding due to the essentially imperceivable flicker, which is expected to substantially reduce discomfort compared to interventions with stroboscopic flicker.


Asunto(s)
Enfermedad de Alzheimer , Animales , Humanos , Estimulación Luminosa/métodos
20.
Opt Express ; 19 Suppl 2: A166-72, 2011 Mar 14.
Artículo en Inglés | MEDLINE | ID: mdl-21445218

RESUMEN

We have theoretically investigated the influence of antireflective sub-wavelength structures on a monolithic white light-emitting diode (LED). The simulation is based on the rigorous coupled wave analysis (RCWA) algorithm, and both cylinder and moth-eye structures have been studied in the work. Our simulation results show that a moth-eye structure enhances the light extraction efficiency over the entire visible light range with an extraction efficiency enhancement of up to 26 %. Also for the first time to our best knowledge, the influence of sub-wavelength structures on both the color rendering index (CRI) and the correlated color temperature (CCT) of the monolithic white LED have been demonstrated. The CRI of the monolithic white LED could be improved from 92.68 to around 94 by applying a cylinder structure, and the CCT could be modified in a very large range with appropriate design of the cylinder structure.

SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA