Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 27
Filtrar
Más filtros

Bases de datos
País/Región como asunto
Tipo del documento
País de afiliación
Intervalo de año de publicación
1.
AJR Am J Roentgenol ; 219(2): 303-313, 2022 08.
Artículo en Inglés | MEDLINE | ID: mdl-35195432

RESUMEN

BACKGROUND. Imaging findings represent key criteria for diagnosing chronic pancreatitis in children. Understanding radiologists' agreement for imaging findings is critical to standardizing and optimizing diagnostic criteria. OBJECTIVE. The purpose of this study is to evaluate the interobserver agreement among experienced pediatric radiologists for subjective, quantitative, and semiquantitative imaging findings of chronic pancreatitis in children. METHODS. In this retrospective study, CT or MRI examinations performed in children with chronic pancreatitis were submitted by six sites participating in the INSPPIRE (International Study Group of Pediatric Pancreatitis: In Search for a Cure) Consortium. One pediatric radiologist from each of the six sites reviewed examinations; three of the radiologists independently reviewed all CT examinations, and the other three radiologists independently reviewed all MRI examinations. Reviewers recorded 13 categoric imaging findings of chronic pancreatitis and measured pancreas thickness and pancreatic duct diameter. Agreement was assessed using kappa coefficients for the categoric variables and intraclass correlation coefficients (ICCs) for the continuous variables. RESULTS. A total of 76 CT and 80 MRI examinations performed in 110 children (65 girls and 45 boys; mean age, 11.3 ± 4.6 [SD] years) were reviewed. For CT, kappa coefficients for categoric findings ranged from -0.01 to 0.81, with relatively high kappa coefficients noted for parenchymal calcifications (κ = 0.81), main pancreatic duct dilatation (κ = 0.63), and atrophy (κ = 0.52). ICCs for parenchymal thickness measurements ranged from 0.57 in the pancreas head to 0.80 in the body and tail. The ICC for duct diameter was 0.85. For MRI, kappa coefficients for categoric findings ranged from -0.01 to 0.74, with relatively high kappa coefficients noted for main duct irregularity (κ = 0.74), side branch dilatation (κ = 0.70), number of dilated side branches (κ = 0.65), and main duct dilatation (κ = 0.64); kappa coefficient for atrophy was 0.52. ICCs for parenchymal thickness measurements ranged from 0.53 for the neck and body individually to 0.68 in the tail. ICC for duct diameter was 0.77. CONCLUSION. Interobserver agreement was fair to moderate for most CT and MRI findings of chronic pancreatitis in children. CLINICAL IMPACT. This study highlights challenges for the imaging diagnosis of pediatric chronic pancreatitis. Standardized and/or objective criteria are needed given the importance of imaging in diagnosis.


Asunto(s)
Pancreatitis Crónica , Adolescente , Atrofia , Niño , Dilatación Patológica , Femenino , Humanos , Imagen por Resonancia Magnética/métodos , Masculino , Variaciones Dependientes del Observador , Pancreatitis Crónica/diagnóstico por imagen , Estudios Retrospectivos , Tomografía Computarizada por Rayos X/métodos
2.
Pediatr Radiol ; 52(4): 752-764, 2022 Apr.
Artículo en Inglés | MEDLINE | ID: mdl-34355264

RESUMEN

When infants are identified with a difference of sex development (DSD), a thoughtful approach to imaging is essential to appropriate clinical management. This review provides a comprehensive guide for radiologists who are tasked with performing this critical assignment. We review the embryologic basis of DSDs, with attention to the imaging findings that can indicate specific diagnoses. We also discuss techniques for optimal imaging, including strategies for identifying the gonads by US, tactics for performing genitograms with fluoroscopy and contrast-enhanced US, and the appropriate utilization of MRI. Finally, we review the clinical data and imaging findings that characterize some of the most common DSDs, including congenital adrenal hyperplasia, complete androgen insensitivity syndrome and gonadal dysgenesis.


Asunto(s)
Hiperplasia Suprarrenal Congénita , Trastornos del Desarrollo Sexual , Síndrome de Turner , Hiperplasia Suprarrenal Congénita/diagnóstico , Trastornos del Desarrollo Sexual/diagnóstico por imagen , Femenino , Humanos , Lactante , Masculino , Radiólogos , Desarrollo Sexual
3.
Pediatr Radiol ; 51(12): 2387-2395, 2021 Nov.
Artículo en Inglés | MEDLINE | ID: mdl-33978789

RESUMEN

Imaging plays a crucial role in evaluating newborns and infants with cloacal and urogenital malformations. Contrast-enhanced genitosonography (ceGS) and contrast-enhanced colosonography (ceCS) are sensitive and radiation-free alternatives to fluoroscopic genitography and colography for diagnosis and surgical planning. These imaging techniques are performed by instilling a US contrast agent into specific body cavities to define the genitourinary and colorectal anatomy. This review article presents the experience with ceGS and ceCS applications in children, focusing on the background, examination technique, and interpretation of imaging findings, as well as strengths and weaknesses compared to conventional techniques.


Asunto(s)
Cloaca , Anomalías Urogenitales , Animales , Niño , Medios de Contraste , Fluoroscopía , Humanos , Lactante , Recién Nacido
4.
Pediatr Radiol ; 50(3): 363-370, 2020 03.
Artículo en Inglés | MEDLINE | ID: mdl-31745596

RESUMEN

BACKGROUND: Pediatric elbow fractures are common but remain challenging to accurately diagnose. Digital tomosynthesis is a technique that has shown promise in difficult adult fracture patterns but has not been formally studied in the pediatric population. OBJECTIVE: To assess the added value of digital tomosynthesis on the detection and diagnostic confidence of pediatric elbow fractures. MATERIALS AND METHODS: A retrospective study was performed between January 2016 and December 2017 in pediatric patients (≤18 years) to assess the ability of conventional elbow radiographs and digital tomosynthesis to detect elbow fractures. One hundred twenty-one pediatric patients with concern for pediatric elbow trauma (64 males, 57 females; mean age: 8.1 years, range: 1 year to 17 years) were imaged with both conventional elbow radiographs and digital tomosynthesis. Two blinded pediatric radiologists identified fractures and indicated their diagnostic confidence. Observer agreement was assessed with Cohen's Kappa coefficient and a nonparametric Wilcoxon rank sum test was used to compare the degree of diagnostic confidence between standard radiographs alone and standard radiographs with digital tomosynthesis. McNemar's test was used to assess the difference in the rate of fracture detection between the two methods and sensitivity, specificity, precision, accuracy and diagnostic odds ratios were calculated. RESULTS: Compared with standard radiographs alone, standard radiographs with digital tomosynthesis improved inter-rater agreement, sensitivity, specificity, accuracy, precision and the diagnostic odds ratio for fracture detection and increased diagnostic confidence (Rater 1: P=0.01, Rater 2: P=0.003). CONCLUSION: The addition of digital tomosynthesis with conventional elbow radiographs improves diagnostic confidence and performance for the detection of pediatric elbow fractures.


Asunto(s)
Lesiones de Codo , Codo/diagnóstico por imagen , Fracturas Óseas/diagnóstico por imagen , Tomografía Computarizada por Rayos X/métodos , Adolescente , Niño , Preescolar , Femenino , Humanos , Lactante , Masculino , Reproducibilidad de los Resultados , Estudios Retrospectivos , Sensibilidad y Especificidad
5.
Pediatr Radiol ; 49(12): 1643-1651, 2019 11.
Artículo en Inglés | MEDLINE | ID: mdl-31686170

RESUMEN

Imaging pediatric elbow trauma in the acute setting remains diagnostically challenging given difficult patient positioning, multiple ossification centers of the pediatric elbow, overlapping structures, and complex joint anatomy. Digital tomosynthesis is a technique where the X-ray source travels across a limited arc angle, obtaining a series of low-dose exposures that are in turn digitally reconstructed to produce high in-plane resolution at a relatively low overall radiation dose. Digital tomosynthesis is now more commonly integrated into standard radiographic machines and offers a new and exciting way to assess the pediatric elbow. In this review article we discuss the clinical applications of digital tomosynthesis in pediatric elbow trauma along with challenges related to technique, patient positioning and artifacts.


Asunto(s)
Lesiones de Codo , Articulación del Codo/diagnóstico por imagen , Intensificación de Imagen Radiográfica/métodos , Interpretación de Imagen Radiográfica Asistida por Computador/métodos , Tomografía Computarizada por Rayos X/métodos , Niño , Humanos
6.
Pediatr Radiol ; 49(7): 854-861, 2019 06.
Artículo en Inglés | MEDLINE | ID: mdl-31154501

RESUMEN

BACKGROUND: To our knowledge, the fluoroscopic practice patterns of pregnant diagnostic radiologists have not been documented. OBJECTIVE: To describe the fluoroscopic practice patterns during pregnancy among members of the Society for Pediatric Radiology (SPR) and potential impact on career and professional relationships. MATERIALS AND METHODS: After approval from the SPR, we sent all 1,847 SPR members an email link to an anonymous online survey that queried how pregnancy affects a practicing radiologist who performs fluoroscopy. RESULTS: Of the 398 responses (65% female, 35% male), most female respondents (78%) reported having been pregnant while practicing radiology and the majority (85%) performed fluoroscopy during pregnancy. Most performed fluoroscopy during all three trimesters (first 78%, second 90%, third 87%) and the majority (81%) used double-lead. Forty-six percent indicated that their fluoroscopic responsibilities during pregnancy were stressful. Of those who opted to perform fewer fluoroscopy studies, 20% indicated that it impacted negatively on their career or professional relationships. After witnessing a pregnant co-worker perform fewer fluoroscopic studies, 11% (4% male; 16% female; P<0.05) of respondents observed a subsequent negative impact on the co-worker's career or professional relationships. CONCLUSION: The majority of responding female SPR members had performed fluoroscopy during pregnancy and most performed fluoroscopy during their entire pregnancy with double-lead. Differences between self-reported adversity and observed adversity of performing less fluoroscopy during pregnancy speak to the lack of awareness of the issues, particularly among male colleagues. A clear policy with regard to performing fluoroscopy during pregnancy for all radiologists in every department is necessary.


Asunto(s)
Fluoroscopía/efectos adversos , Exposición Profesional/efectos adversos , Pautas de la Práctica en Medicina/estadística & datos numéricos , Embarazo , Radiólogos , Femenino , Humanos , Masculino , Sociedades Médicas , Encuestas y Cuestionarios , Estados Unidos
7.
Pediatr Radiol ; 49(7): 933-940, 2019 06.
Artículo en Inglés | MEDLINE | ID: mdl-30623211

RESUMEN

BACKGROUND: Optimized MRI parameters can be leveraged to improve signal intensity, accelerate imaging acquisition and increase resolution. Higher-resolution imaging with a small field of view (FOV) has been proposed as standard practice for investigating sacroiliac (SI) joints, but the improvement in disease detection and characterization over pelvic imaging with large FOV has not been established. OBJECTIVE: The purpose of this study was to compare dedicated MR images of the SI joints with survey imaging (large-FOV pelvic MRI) for detecting sacroiliitis. MATERIALS AND METHODS: Fifty-eight pediatric patients suspected of having sacroiliitis underwent dedicated sacroiliac joint and survey pelvic imaging at the same imaging session. We independently evaluated the small- and large-FOV image data sets for presence or absence of sacroiliitis, e.g., bone marrow edema, erosions and synovitis. We used nonparametric statistical tests to compare lesion scores for severity of inflammation. We created test characteristics for the survey pelvic images (low-resolution images of the sacroiliac joints) using dedicated sacroiliac images (small-FOV, high-resolution images) as the gold standard. RESULTS: Dedicated sacroiliac small-FOV MRI detected more sacroiliitis compared to survey pelvic imaging with large FOV (χ2=6.125, P=0.013). Readers detected significantly more features of inflammation on small- compared to large-FOV images, e.g., erosions (P=0.039), synovitis (P=0.009), sclerosis (P=0.017) and osteitis (P=0.001). Test characteristics for pelvic large-FOV imaging were sensitivity=0.76, specificity=1.00, positive predictive value = 1.00 and negative predictive value = 0.75. CONCLUSION: This study provides test characteristics for survey pelvic MRI with lower-resolution large-field-of-view images as a screening tool for detecting sacroiliitis. Pelvic screening studies with large FOV have lower sensitivity, and dedicated sacroiliac MRI with small FOV is superior in detecting sacroiliitis when compared to pelvic screening MRI.


Asunto(s)
Imagen por Resonancia Magnética/métodos , Huesos Pélvicos/diagnóstico por imagen , Sacroileítis/diagnóstico por imagen , Adolescente , Niño , Preescolar , Medios de Contraste , Femenino , Humanos , Masculino , Estudios Retrospectivos , Sensibilidad y Especificidad , Adulto Joven
8.
J Pediatr Hematol Oncol ; 40(4): 290-294, 2018 05.
Artículo en Inglés | MEDLINE | ID: mdl-29432308

RESUMEN

Hodgkin lymphoma (HL) is the most common malignancy affecting adolescents and young adults. Treatment with a combination of chemotherapy and radiation results in cure rates of >90%. However, radiation therapy causes significant late effects and avoiding radiation entirely for patients who respond to chemotherapy is an accepted strategy. Since 2011, 28 consecutive patients diagnosed with classic HL have been treated with doxorubicin, bleomycin, vinblastine, and dacarbazine (ABVD) for 4 to 6 cycles. Patients who achieved a complete metabolic response (CMR) as assessed by [F] fluorodeoxyglucose positron emission tomography by the end of chemotherapy did not receive radiation. Among the 27 evaluable patients, 26/27 (96.2%) achieved a CMR with ABVD alone with 24/27 (88.9%) having achieved a CMR after 2 cycles. Event-free survival at 5 years is 90.5% and overall survival is 100% with a median follow-up time of 22.4 and 22.1 months, respectively. Treating pediatric and young adult HL patients with ABVD alone results in CMRs in >95% of patients. Patients who were refractory to ABVD or relapsed after treatment eventually achieved remission with a combination of standard and novel salvage therapies. This regimen demonstrates the feasibility of avoiding upfront radiation in newly diagnosed pediatric HL patients.


Asunto(s)
Protocolos de Quimioterapia Combinada Antineoplásica/administración & dosificación , Fluorodesoxiglucosa F18/administración & dosificación , Enfermedad de Hodgkin , Tomografía de Emisión de Positrones , Adolescente , Adulto , Bleomicina/administración & dosificación , Niño , Dacarbazina/administración & dosificación , Supervivencia sin Enfermedad , Doxorrubicina/administración & dosificación , Femenino , Enfermedad de Hodgkin/diagnóstico por imagen , Enfermedad de Hodgkin/tratamiento farmacológico , Enfermedad de Hodgkin/mortalidad , Humanos , Masculino , Estudios Retrospectivos , Tasa de Supervivencia , Vinblastina/administración & dosificación
9.
Radiographics ; 37(7): 2063-2082, 2017.
Artículo en Inglés | MEDLINE | ID: mdl-29131768

RESUMEN

Abdominal and pelvic hernias may be indolent and detected incidentally, manifest acutely with pain and distress, or cause chronic discomfort. Physical examination findings are often ambiguous and insufficient for optimal triage. Therefore, accurate anatomic delineation and identification of complications are critical for effective treatment planning. Imaging, particularly computed tomography, provides a vital understanding of the hernia's location and size, involved viscera, and severity of associated complications. Reader familiarity with the imaging appearances and anatomic landmarks of hernias is important for correct diagnosis, which may impact preoperative planning and reduce morbidity. This article reviews the appearance of anatomic structures in the abdominal wall and pelvis that are important for diagnosing common and uncommon abdominal and pelvic hernias, and it highlights key imaging features that are helpful for differentiating hernias, mimics, and their complications. Online DICOM image stacks are available for this article . ©RSNA, 2017.


Asunto(s)
Hernia/diagnóstico por imagen , Puntos Anatómicos de Referencia , Diagnóstico Diferencial , Humanos , Imagen por Resonancia Magnética , Tomografía Computarizada por Rayos X , Ultrasonografía
10.
Pediatr Radiol ; 47(9): 1101-1108, 2017 Aug.
Artículo en Inglés | MEDLINE | ID: mdl-28779197

RESUMEN

Intussusception is a common etiology of acute abdominal pain in children. Over the last 70 years, there have been significant changes in how we diagnose and treat intussusception, with a more recent focus on the role of ultrasound. In this article we discuss historical and current approaches to intussusception, with an emphasis on ultrasound as a diagnostic and therapeutic modality.


Asunto(s)
Intususcepción/diagnóstico por imagen , Ultrasonografía/métodos , Niño , Preescolar , Medios de Contraste , Diagnóstico Diferencial , Enema , Humanos , Lactante , Recién Nacido , Intususcepción/terapia , Radiografía Abdominal
11.
Pediatr Radiol ; 47(12): 1572-1579, 2017 Nov.
Artículo en Inglés | MEDLINE | ID: mdl-28573315

RESUMEN

This review provides a comprehensive and practical approach to pediatric percutaneous renal transplant biopsies, highlighting techniques and strategies to optimize adequate sample yield and ensure patient safety. In children with end-stage renal disease, transplantation is the preferred choice of therapy, providing for overall lower long-term morbidity and mortality compared with dialysis. In the ongoing management of renal transplant patients, core tissue sampling via a percutaneous renal biopsy remains the gold standard when transplant dysfunction is suspected. Indications for renal transplant biopsy and techniques/tools for adequate sample yield are discussed. Strategies for common challenges such as poor visualization and renal transplant mobility are addressed. We discuss the clinical signs, techniques and imaging findings for common complications including hematomas, arteriovenous fistulas and pseudoaneurysms. Although the percutaneous renal transplant biopsy procedure is generally safe with rare complications, care must be taken to ensure major complications are promptly recognized and treated. Adequate tissue samples obtained via renal biopsy are imperative to promptly identify transplant rejection to provide valuable information for patient diagnosis, treatment and outcomes. Radiologist and nephrologist attention to proper ultrasound techniques and optimal biopsy tools are critical to ensure tissue adequacy and minimize complications.


Asunto(s)
Rechazo de Injerto/diagnóstico por imagen , Rechazo de Injerto/patología , Biopsia Guiada por Imagen , Fallo Renal Crónico/cirugía , Trasplante de Riñón , Ultrasonografía Intervencional , Niño , Humanos
12.
Emerg Radiol ; 24(6): 653-660, 2017 Dec.
Artículo en Inglés | MEDLINE | ID: mdl-28725923

RESUMEN

PURPOSES: To assess the ability of a single isotropic 3D T2 FSE sequence to identify the normal appendix in children with potential implication as alternative second-line modality in pediatric appendicitis. MATERIALS AND METHODS: Retrospective review of MR abdomino-pelvis or pelvis in children from Oct 2014-Dec 2016 was done. Only exams with 3D T2 FSE sequence performed on a single scanner type were selected. Patients with history of post appendectomy, studies in which field of view did not include ileocecal valve, with technical and protocol errors, or with fat-saturated acquisition were excluded. All images were blindly reviewed by three radiologists. The following questions were asked: (1) Is the appendix visualized?, (2) What is the most clearly demonstrable plane?, (3) Where is the appendix located?, (4) Are there any findings indicating appendicitis? Average pairwise percentage and Fleiss Kappa were used to assess the inter-rater agreement on the visualization and location of the appendix. RESULTS: A total of 22 MRI studies were reviewed (F = 13:M = 9, Mean age = 11.45 yrs. [SD = 4.3]). Total MRI scan time was estimated at 6 mins. Readers saw appendix in 72.7-81.8%, and saw with high confidence in 12 cases (54.5%), low confidence in 4-6 case (18.2-27.3%), and did not see in 4-6 cases(18.2-27.3%). The average pairwise percentage agreement was 71.2%. Fleiss Kappa of overall rating of visualization was 0.52 (p < 0.001). Fleiss Kappa of high confidence of visualization was 0.76 (p < 0.001). Reader 1 and reader 2 saw the appendix best on the axial plane. Reader 3 saw the appendix best on the coronal plane. For location, deep pelvis was the most common identified location. The average pairwise percentage agreement was 68.2% and Fleiss Kappa was 0.76 (p < 0.001). There is no findings indicating appendicitis. CONCLUSION: A single 3D T2 FSE sequence had good ability to detect normal appendices and also allowed multiplanar reconstructions, which may use as a single-sequence protocol in cases of suspected appendicitis in children when ultrasound is inconclusive.


Asunto(s)
Apendicitis/diagnóstico por imagen , Apéndice/diagnóstico por imagen , Imagenología Tridimensional , Imagen por Resonancia Magnética/métodos , Niño , Femenino , Humanos , Interpretación de Imagen Asistida por Computador , Masculino , Estudios Retrospectivos
13.
Emerg Radiol ; 24(4): 369-376, 2017 Aug.
Artículo en Inglés | MEDLINE | ID: mdl-28289906

RESUMEN

PURPOSE: Computed tomography (CT) use in emergency departments represents a significant contribution to pediatric patients' exposure to ionizing radiation. Here, we evaluate whether ultralow-dose chest CT can be diagnostically adequate for other diagnoses and whether model-based iterative reconstruction (MBIR) can improve diagnostic adequacy compared to adaptive statistical iterative reconstruction (ASIR) at ultralow doses. METHODS: Twenty children underwent chest CTs: 10 standard-dose reconstructed with ASIR and 10 ultralow-dose reconstructed with ASIR and MBIR. Four radiologists assessed images for their adequacy to exclude five hypothetical diagnoses: foreign body, fracture, lung metastasis, pulmonary infection, and interstitial lung disease. Additionally, pairwise comparison for subjective image quality was used to compare ultralow-dose chest CT with ASIR and MBIR. Radiation dose and objective image noise measures were obtained. RESULTS: For exclusion of an airway foreign body, the adequacy of ultralow-dose CT was comparable to standard-dose (p = 0.6). For the remaining diagnoses, ultralow-dose CT was inferior to standard-dose (p = 0.03-<0.001). MBIR partially recovered the adequacy of ultralow-dose CT to exclude pulmonary infection (p = 0.017), but was suboptimal for the other diagnoses. Image noise was significantly lower with MBIR compared to ASIR in ultralow-dose CT (p < 0.001), although subjective preference showed only a slight advantage of MBIR (58 versus 42%). CONCLUSIONS: Ultralow-dose chest CT may be adequate for airway assessment, but suboptimal for the evaluation parenchymal lung disease. Although MBIR improves objective and subjective image quality, it does not completely restore the diagnostic adequacy of ultralow-dose CT when compared to standard-dose CT.


Asunto(s)
Dosis de Radiación , Interpretación de Imagen Radiográfica Asistida por Computador/métodos , Radiografía Torácica/métodos , Tomografía Computarizada por Rayos X/métodos , Adolescente , Algoritmos , Niño , Femenino , Humanos , Masculino , Estudios Retrospectivos
14.
Eur Radiol ; 26(5): 1387-95, 2016 May.
Artículo en Inglés | MEDLINE | ID: mdl-26304803

RESUMEN

OBJECTIVE: To optimise image quality and reduce radiation exposure for infant body CT imaging. METHODS: An image quality CT phantom was created to model the infant body habitus. Image noise, spatial resolution, low contrast detectability and tube current modulation (TCM) were measured after adjusting CT protocol parameters. Reconstruction method (FBP, hybrid iterative and model-based iterative), image quality reference parameter, helical pitch and beam collimation were systematically investigated for their influence on image quality and radiation output. RESULTS: Both spatial and low contrast resolution were significantly improved with model-based iterative reconstruction (p < 0.05). A change in the helical pitch from 0.969 to 1.375 resulted in a 23% reduction in total TCM, while a change in collimation from 20 to 40 mm resulted in a 46% TCM reduction. Image noise and radiation output were both unaffected by changes in collimation, while an increase in pitch enabled a dose length product reduction of ~6% at equivalent noise. An optimised protocol with ~30% dose reduction was identified using model-based iterative reconstruction. CONCLUSIONS: CT technology continues to evolve and require protocol redesign. This work provides an example of how an infant-specific phantom is essential for leveraging this technology to maintain image quality while reducing radiation exposure. KEY POINTS: • A size-specific phantom is critical in protocol development for infant CT. • New reconstruction technology enables ~30% dose reduction at equivalent image quality. • A consistent performance is observed for this scanner system across protocol changes. • A tradeoff exists between reducing exposure time and enabling tube current modulation.


Asunto(s)
Fantasmas de Imagen , Dosis de Radiación , Tomografía Computarizada por Rayos X/métodos , Humanos , Lactante
15.
Pediatr Radiol ; 46(13): 1787-1796, 2016 Dec.
Artículo en Inglés | MEDLINE | ID: mdl-27580908

RESUMEN

BACKGROUND: Games with educational intent offer a possible advantage of being more interactive and increasing learner satisfaction. OBJECTIVE: We conducted a two-armed experiment to evaluate student satisfaction and content mastery for an introductory pediatric radiology topic, taught by either an interactive digital game or with a traditional didactic lecture. MATERIALS AND METHODS: Medical students participating in a fourth-year radiology elective were invited to participate. Student cohorts were alternatively given a faculty-supervised 1h session playing a simple interactive digital Tic-tac-toe quiz module on pediatric gastrointestinal radiology or a 1h didactic introductory lecture on the same topic. Survey questions assessed the learners' perceived ability to recall the material as well as their satisfaction with the educational experience. Results of an end-of-rotation exam were reviewed to evaluate a quantitative measure of learning between groups. Survey responses were analyzed with a chi-squared test. Exam results for both groups were analyzed with a paired Student's t-test. RESULTS: Students in the lecture group had higher test scores compared to students in the game group (4.0/5 versus 3.6/5, P = 0.045). Students in the lecture group reported greater understanding and recall of the material than students in the game group (P < 0.001 and P = 0.004, respectively). Students in the lecture group perceived the lecture to be more enjoyable and a better use of their time compared to those in the game group (P = 0.04 and P < 0.001, respectively). There was no statistically significant difference between the lecture and game group in ability to maintain interest (P = 0.187). In comparison to pre-survey results, there was a statistically significant decrease in interest for further digital interactive materials reported by students in the game group (P = 0.146). CONCLUSION: Our experience supported the use of a traditional lecture over a digital game module. While these results might be affected by the specific lecture and digital content in any given comparison, a digital module is not always the superior option.


Asunto(s)
Enfermedades Gastrointestinales/diagnóstico por imagen , Aprendizaje , Pediatría/educación , Radiología/educación , Juegos de Video , Adulto , Educación de Pregrado en Medicina , Evaluación Educacional , Femenino , Humanos , Masculino , Encuestas y Cuestionarios
16.
AJR Am J Roentgenol ; 204(1): 8-14, 2015 Jan.
Artículo en Inglés | MEDLINE | ID: mdl-25539230

RESUMEN

OBJECTIVE: Biomedical imaging research relies heavily on the subjective and semi-quantitative reader analysis of images. Current methods are limited by interreader variability and fixed upper and lower limits. The purpose of this study was to compare the performance of two assessment methods, pairwise comparison and Likert scale, for improved analysis of biomedical images. MATERIALS AND METHODS: A set of 10 images with varying degrees of image sharpness was created by digitally blurring a normal clinical chest radiograph. Readers assessed the degree of image sharpness using two different methods: pairwise comparison and a 10-point Likert scale. Reader agreement with actual chest radiograph sharpness was calculated for each method by use of the Lin concordance correlation coefficient (CCC). RESULTS: Reader accuracy was highest for pairwise comparison (CCC, 1.0) and ranked Likert (CCC, 0.99) scores and lowest for nonranked Likert scores (CCC, 0.83). Accuracy improved slightly when readers repeated their assessments (CCC, 0.87) or had reference images available (CCC, 0.91). CONCLUSION: Pairwise comparison and ranked Likert scores yield more accurate reader assessments than nonranked Likert scores.


Asunto(s)
Algoritmos , Interpretación Estadística de Datos , Variaciones Dependientes del Observador , Psicometría/métodos , Interpretación de Imagen Radiográfica Asistida por Computador/métodos , Radiografía Torácica/métodos , Humanos , Reproducibilidad de los Resultados , Sensibilidad y Especificidad
17.
Pediatr Radiol ; 47(9): 1029-1030, 2017 08.
Artículo en Inglés | MEDLINE | ID: mdl-28779208
19.
Front Pediatr ; 9: 707052, 2021.
Artículo en Inglés | MEDLINE | ID: mdl-34422729

RESUMEN

Background and Aim: Congenital diaphragmatic hernia (CDH) is a rare defect often associated with pulmonary hypoplasia and abnormal pulmonary vascular development. Even after successful hernia repair, pulmonary disease may persist into adulthood. Impaired diaphragmatic motility may lead to compromised respiratory function long after index repair. This study investigates whether a novel ultrasound measurement, the diaphragmatic excursion ratio, can be a simple and non-invasive method to evaluate routine diaphragmatic motion after CDH repair, and whether it correlates with adverse surgical and respiratory outcomes. Materials and Methods: A cross-sectional study was conducted in consecutive patients who presented at medium-term follow-up visit between December 2017 and December 2018 after CDH repair at single pediatric hospital. Transthoracic ultrasound was performed with craniocaudal diaphragmatic excursion measured bilaterally during routine breathing. Diaphragmatic excursion ratios (diaphragmatic excursion of repaired vs. unrepaired side) were calculated and retrospectively compared with clinical data including demographics, length of stay, respiratory adjuncts, oral feeding, and need for gastrostomy. Results: Thirty-eight patients (median age at ultrasound, 24 months, interquartile range 11-60) were evaluated. Nine patients underwent primary repair, 29 had non-primary repair (internal oblique muscle flap or mesh patch). Patients with a diaphragmatic excursion ratio below the median (0.54) had longer hospital stays (median 77 vs. 28 days, p = 0.0007) more ventilator days (median 16 vs. 9 days, p =0.004), and were more likely to have been discharged on oxygen (68 vs. 16%, p = 0.001). They were also less likely to be exclusively taking oral feeds at 1-year post-surgery (37 vs. 74%, p = 0.02) and more likely to require a gastrostomy tube in the first year of life (74 vs. 21%, p = 0.003). Conclusions: Transthoracic ultrasound after CDH repair is practical method to assess diaphragm motion, and decreased diaphragm excursion ratio is associated with worse respiratory outcomes, a longer length of stay, and dependence on gastrostomy tube feeding within 1 year. Further prospective studies may help validate this novel ultrasound measurement and offer prognostic value.

20.
Acad Radiol ; 27(5): 739-743, 2020 05.
Artículo en Inglés | MEDLINE | ID: mdl-31420160

RESUMEN

RATIONALE AND OBJECTIVES: With the introduction of new communication channels, such as encrypted messaging and online electronic medical record patient portals, there are ever-increasing ways for patients and their families to access their medical information. While patient preferences regarding how they receive the results of their radiology examinations have been assessed in the adult population, there is limited data on parent preferences for pediatric radiology patients. MATERIALS AND METHODS: The aim of this study was to determine how the parents of pediatric radiology patients prefer to receive the results of their child's imaging studies. The study design was an institutional review board-approved anonymous voluntary survey distributed to parents in a pediatric radiology waiting room. RESULTS: Of the current possible ways to receive radiology results, most parents preferred to receive their child's radiology results from the referring doctor (65%). A minority of parents preferred to receive the results from a radiologist in-person (16%) or via the radiology report (16%). In multiple hypothetical scenarios, parents also preferred to receive radiology results from the referring doctor rather than the radiologist, with the single exception being when no subsequent appointment with the referring doctor was planned. When asked to prioritize the most important aspect of receiving radiology test results, most parents prefer having results available quickly (65%). CONCLUSION: This survey suggests that in the pediatric radiology realm, efforts toward timely reporting will likely have a greater impact on patient satisfaction than prioritizing more in-person radiologist-patient communication.


Asunto(s)
Portales del Paciente , Radiología , Adulto , Niño , Comunicación , Humanos , Padres , Derivación y Consulta
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA