Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 74
Filtrar
Más filtros

Bases de datos
País/Región como asunto
Tipo del documento
Intervalo de año de publicación
1.
Abdom Imaging ; 40(6): 1666-74, 2015 Aug.
Artículo en Inglés | MEDLINE | ID: mdl-25488345

RESUMEN

OBJECTIVE: To determine the effectiveness of the CT histogram method to characterize indeterminate adrenal nodules above 10 Hounsfield units (HU) on noncontrast CT. MATERIALS AND METHODS: Retrospective review of clinical CT data from January 2005 through 2008 identified 194 indeterminate adrenal nodules (>10 HU on noncontrast CT) in 175 patients. 20 nodules in 18 patients were excluded due to large standard deviation (SD > 30) of HU values. Of the remaining 174 nodules, 131 were classified as benign lipid-poor nodules based on size stability for ≥1 year (104), in- and opposed-phase MRI (17), adrenal washout CT (3), or biopsy (7). 43 were classified as malignant by size increase over a short time (30), avid FDG uptake on PET/CT (15), or biopsy (5). Histogram analysis was performed by drawing a circular region of interest on all adrenal nodules. Mean attenuation, total number of pixels, number of negative pixels, and percentage of negative pixels were recorded for each nodule. RESULTS: At the threshold value of >10% negative pixels, 59/131 benign nodules were correctly characterized, but 1/43 malignant nodules was falsely characterized as benign (sensitivity 45%, specificity 98%, positive predictive value 98%). With a slightly higher threshold value of >15% negative pixels, there were no false benign judgments. 36 nodules had more than 15% negative pixels, all of which were benign (sensitivity 27%, specificity 100%, positive predictive value 100%). In the subgroup of benign nodules measuring 11-20 HU, 80% and 54% were identified with threshold values of >10% and >15% negative pixels, respectively. CONCLUSION: The CT histogram method with a threshold value of >10% negative pixels can identify many benign adrenal nodules with attenuation values >10 HU on unenhanced CT with extremely high specificity. A threshold of >15% negative pixels can achieve 100% specificity. This method is highly robust provided very "noisy" CT examinations (SD > 30) are eliminated.


Asunto(s)
Neoplasias de las Glándulas Suprarrenales/diagnóstico por imagen , Glándulas Suprarrenales/diagnóstico por imagen , Interpretación de Imagen Asistida por Computador/métodos , Tomografía Computarizada por Rayos X/métodos , Diagnóstico Diferencial , Femenino , Humanos , Masculino , Persona de Mediana Edad , Reproducibilidad de los Resultados , Estudios Retrospectivos , Sensibilidad y Especificidad
2.
AJR Am J Roentgenol ; 201(1): W75-80, 2013 Jul.
Artículo en Inglés | MEDLINE | ID: mdl-23789700

RESUMEN

OBJECTIVE: The purpose of this study was to compare the diagnostic efficacy and cost implications of a proposed two-tiered approach to MRI in patients with headache. MATERIALS AND METHODS: We identified 245 consecutive patients with headache using MRI studies performed at a tertiary care facility between October 2009 and July 2011. Three radiologists prospectively used FLAIR sequences from these MR studies to diagnose underlying abnormality or to identify the need for a comprehensive MRI study. We compared the diagnostic efficacy and the cost implications of such a two-tiered approach with those of conventional MRI from the perspectives of the payer, the patient, and the imaging facility. RESULTS: The sensitivity and specificity for two-tiered (83.3% and 100%, respectively) and conventional (91% and 97.8%, respectively) MRI approaches were not significantly different. Assuming a 50% reduction in the payment for the initial limited MRI performed as a first step of the two-tiered approach, this approach would have resulted in 44.8% savings to the payer. A substantial reduction in the scanner utilization time from 4168 minutes to 1249 minutes for the two-tiered approach would have enabled increased throughput at the imaging facility. Although 27 (11%) patients would have been recalled for a comprehensive MRI study in the two-tiered approach, the average time spent in the scanner by each patient would have been less for the two-tiered approach (5.1 minutes vs 17.0 minutes). CONCLUSION: A two-tiered approach to MRI can serve as a viable cost-effective alternative to the conventional approach.


Asunto(s)
Cefalea/diagnóstico , Imagen por Resonancia Magnética/economía , Adolescente , Adulto , Anciano , Anciano de 80 o más Años , Medios de Contraste/economía , Ahorro de Costo , Análisis Costo-Beneficio , Femenino , Guías como Asunto , Humanos , Masculino , Persona de Mediana Edad , Estudios Prospectivos , Retratamiento/economía , Sensibilidad y Especificidad , Factores de Tiempo
3.
Radiology ; 265(1): 151-7, 2012 Oct.
Artículo en Inglés | MEDLINE | ID: mdl-22798224

RESUMEN

PURPOSE: To determine which measurement of donor renal size on computed tomographic (CT) angiograms has the greatest correlation with renal function preoperatively in the donor and postoperatively in the transplant recipient. MATERIALS AND METHODS: Informed consent was waived for this retrospective HIPAA-compliant study approved by the institutional review board. Renal length, total volume, and cortical volume were measured on renal donor CT angiograms in 111 patients. Preoperative serum creatinine values for donors and postoperative creatinine values for recipients at hospital discharge and 6, 12, 24, and 36 months after transplant were collected, and estimated glomerular filtration rate (eGFR) was calculated. Correlation coefficients with 95% confidence intervals (CIs) were obtained for renal measures and donor eGFR and for renal measures adjusted to recipient body habitus and posttransplant creatinine level in the recipient. Thresholds were set for adjusted length and volumes, and the odds ratio (OR) for creatinine level less than 1.5 mg/dL at 36 months was calculated. RESULTS: Renal volumes and length were correlated with donor eGFR (r=0.58 [95% CI: 0.44, 0.69] for cortical volume, 0.56 [95% CI: 0.42, 0.68] for total volume, and 0.43 [95% CI: 0.27, 0.57] for renal length). All three measures, adjusted to recipient body habitus, were correlated with recipient renal function from discharge (r=-0.41 to -0.43) up to 36 months after transplantation (r=-0.33 to -0.41). By using a threshold of 1.5 for cortical volume to recipient weight, 2.25 for total volume to recipient weight, and 0.175 for renal length to recipient weight, the odds of creatinine level greater than 1.5 mg/dL were four times as great for smaller kidney-to-recipient weight ratios, a statistically significant pattern for cortical volume (OR, 4.07; 95% CI: 1.10, 15.09) but not total volume (OR, 4.24; 95% CI: 0.90, 20.01) or renal length (OR, 4.08; 95% CI: 0.48-34.29). CONCLUSION: Renal length and volumes correlated with recipient renal function up to 36 months after transplant. A low ratio of cortical volume to recipient weight was associated with diminished renal function at 36 months after transplant.


Asunto(s)
Angiografía/métodos , Riñón/diagnóstico por imagen , Trasplante de Hígado , Tomografía Computarizada por Rayos X/métodos , Adolescente , Adulto , Anciano , Biomarcadores/sangre , Intervalos de Confianza , Creatinina/sangre , Femenino , Tasa de Filtración Glomerular , Humanos , Pruebas de Función Renal , Masculino , Persona de Mediana Edad , Nefrectomía , Tamaño de los Órganos , Interpretación de Imagen Radiográfica Asistida por Computador , Reproducibilidad de los Resultados , Estudios Retrospectivos
4.
Neuroradiology ; 54(2): 133-8, 2012 Feb.
Artículo en Inglés | MEDLINE | ID: mdl-21472377

RESUMEN

INTRODUCTION: Assessment of the motion of the cerebellar tonsils is of interest in diseases affecting the CSF flow at the foramen magnum. Cardiac-gated balanced steady-state free-precession technique, which has recently been shown to demonstrate the pulsatile motion of neural structures, appears well suited to allow direct measurement of craniocaudal translation of cerebellar tonsils during the cardiac cycle. Our aim was to assess the intra-observer and inter-observer variability in the assessment of tonsillar motion utilizing this technique. METHODS: We retrospectively identified 44 patients who had undergone MR imaging with cine TrueFISP sequence, as a part of CSF flow study. Two neuroradiologists independently assessed the images. The tonsillar pulsatility was subjectively characterized into none, minimal, and marked categories after review of the images on a cine loop. For patients with identifiable tonsillar motion, the maximal extent of translation of the inferior edge of the cerebellar tonsil was directly measured. Both readers repeated the measurements after a minimum interval of 2 weeks. Intra- and inter-observer variability was characterized by calculating the kappa statistics. RESULTS: The intra-observer agreement for subjective assessment of tonsillar pulsatility was near perfect while the inter-observer agreement was substantial. A good intra- and inter-observer correlation was also seen for the objective measurements of the tonsillar motion. A good correlation was found between the subjective categorization of the tonsillar pulsatility and the objective measurements. CONCLUSION: Steady-state balanced free-precession MR imaging technique allows for a reproducible subjective and objective assessment of tonsillar pulsatility.


Asunto(s)
Técnicas de Imagen Sincronizada Cardíacas/métodos , Enfermedades Cerebelosas/fisiopatología , Cerebelo/fisiopatología , Imagen por Resonancia Magnética/métodos , Adolescente , Adulto , Enfermedades Cerebelosas/líquido cefalorraquídeo , Niño , Preescolar , Femenino , Foramen Magno/fisiopatología , Humanos , Lactante , Modelos Logísticos , Masculino , Reproducibilidad de los Resultados , Estudios Retrospectivos
5.
J Thorac Imaging ; 37(1): 58-65, 2022 Jan 01.
Artículo en Inglés | MEDLINE | ID: mdl-32427649

RESUMEN

PURPOSE: The purpose of this study was to describe the myocardial cut-off sign, assess its ability to distinguish left ventricular pseudoaneurysms (LV PSAs) from true aneurysms (LVAs), and compare its performance with other imaging findings and quantitative measurements used to differentiate LV PSAs from LVAs. MATERIALS AND METHODS: This retrospective single-center study identified patients with preoperative cardiac computed tomography (CT) or magnetic resonance imaging (MRI) and surgically confirmed LVAs or LV PSAs over a 10-year period. Seventeen LV PSAs (11 MRI, 6 CT) and 18 LVAs (10 MRI, 8 CT) were included. The myocardial cut-off sign was objectively a >50% decrease in aneurysm sac wall thickness measured at 1 cm from the aneurysmal neck (measurements at 2 cm were also assessed) and subjectively an abrupt "cut-off" of myocardium for the aneurysm sac for PSA compared with a gradual tapering of sac wall thickness for LVA. Two radiologists independently evaluated images for the subjective presence of this sign. RESULTS: The myocardial cut-off sign was 91% sensitive and 97% specific when measured 1 cm from the aneurysm neck. When measured at 2 cm from the neck, the sign was 100% sensitive and 69% specific. Subjective analysis of whether the myocardium appeared "cut-off" was 94% to 100% sensitive and 78% to 94% specific with excellent agreement for both PSA (κ=0.94) and LVA (κ=0.83). CONCLUSIONS: The myocardial cut-off sign on cardiac CT and MRI is a sensitive and specific finding of LV PSA. Specificity is improved with objective measurements compared with subjective assessment (97% vs. 78% to 94%). This sign may help radiologists distinguish between LV PSAs and LVAs.


Asunto(s)
Aneurisma Falso , Aneurisma Falso/diagnóstico por imagen , Humanos , Imagen por Resonancia Magnética , Miocardio , Estudios Retrospectivos , Función Ventricular Izquierda
6.
Radiology ; 261(3): 950-9, 2011 Dec.
Artículo en Inglés | MEDLINE | ID: mdl-21900623

RESUMEN

PURPOSE: To determine whether quantitative computed tomographic (CT) measurements of emphysema and airway dimensions are associated with lung cancer risk in a screening population. MATERIALS AND METHODS: Institutional review board approval and informed consent for the use of deidentified images were obtained. In this retrospective study, CT scans were analyzed from 279 participants in the CT screening arm of the National Lung Screening Trial who were diagnosed with lung cancer and 279 participants who were not diagnosed with lung cancer after a median follow-up period of 6.6 years. Quantitative CT measurements of emphysema and right upper lobe apical segmental and subsegmental airway dimensions, and multiple patient history-related variables, were compared between the two groups. Significant variables were tested in multivariate models for association with lung cancer by using multiple logistic regression. RESULTS: The emphysema index of percentage upper lung volume less than -950 HU had the strongest association with lung cancer (mean, 10.7% [standard deviation, 13.5] in patients vs 7.2% [standard deviation, 10.4] in control subjects; P < .001), but the relationship was weak (R(2) = 0.015, P < .001, c = 0.57). No CT measures of emphysema had an association with lung cancer independent of the patient medical history variables. Airway dimensions were not associated with lung cancer. CONCLUSION: Quantitative CT measurements of emphysema but not airway dimensions were only weakly associated with lung cancer, demonstrating no potential practical value for clinical risk stratification.


Asunto(s)
Neoplasias Pulmonares/diagnóstico por imagen , Enfisema Pulmonar/diagnóstico por imagen , Tomografía Computarizada por Rayos X/métodos , Anciano , Femenino , Humanos , Modelos Logísticos , Neoplasias Pulmonares/epidemiología , Masculino , Persona de Mediana Edad , Enfisema Pulmonar/epidemiología , Estudios Retrospectivos , Factores de Riesgo , Fumar/efectos adversos , Estados Unidos/epidemiología
7.
Med Phys ; 38(8): 4894-902, 2011 Aug.
Artículo en Inglés | MEDLINE | ID: mdl-21928661

RESUMEN

PURPOSE: To mathematically model the relationship between CT measurements of emphysema obtained from images reconstructed using different section thicknesses and kernels and to evaluate the accuracy of the models for converting measurements to those of a reference reconstruction. METHODS: CT raw data from the lung cancer screening examinations of 138 heavy smokers were reconstructed at 15 different combinations of section thickness and kernel. An emphysema index was quantified as the percentage of the lung with attenuation below -950 HU (EI950). Linear, quadratic, and power functions were used to model the relationship between EI950 values obtained with a reference 1 mm, medium smooth kernel reconstruction and values from each of the other 14 reconstructions. Preferred models were selected using the corrected Akaike information criterion (AICc), coefficients of determination (R2), and residuals (conversion errors), and cross-validated by a jackknife approach using the leave-one-out method. RESULTS: The preferred models were power functions, with model R2 values ranging from 0.949 to 0.998. The errors in converting EI950 measurements from other reconstructions to the 1 mm, medium smooth kernel reconstruction in leave-one-out testing were less than 3.0 index percentage points for all reconstructions, and less than 1.0 index percentage point for five reconstructions. Conversion errors were related in part to image noise, emphysema distribution, and attenuation histogram parameters. Conversion inaccuracy related to increased kernel sharpness tended to be reduced by increased section thickness. CONCLUSIONS: Image reconstruction-related differences in quantitative emphysema measurements were successfully modeled using power functions.


Asunto(s)
Procesamiento de Imagen Asistido por Computador/métodos , Enfisema Pulmonar/diagnóstico por imagen , Tomografía Computarizada por Rayos X/estadística & datos numéricos , Humanos , Procesamiento de Imagen Asistido por Computador/normas , Procesamiento de Imagen Asistido por Computador/estadística & datos numéricos , Modelos Estadísticos , Reproducibilidad de los Resultados
8.
AJR Am J Roentgenol ; 197(6): 1410-6, 2011 Dec.
Artículo en Inglés | MEDLINE | ID: mdl-22109297

RESUMEN

OBJECTIVE: The goal of this work is to review the thoracic foraminal nerve blocks and foraminal epidurals performed at a single institution to determine the incidence and types of immediate complications and pain relief associated with thoracic foraminal nerve blocks. MATERIALS AND METHODS: This retrospective study entailed a comprehensive review of the radiographs and reports of 296 injections performed in 225 examinations on 153 patients (60 men and 93 women). The overall mean age was 51.93 years (mean age for men, 50.71 years [range, 22-85 years]; mean age for women, 53.09 years [range, 18-84 years]). The data were later analyzed with contingency tables and chi-square tests. RESULTS: The overall complication rate was 4.1% (12/296). Complication rates at the different needle tip positions measured on frontal and lateral fluoroscopic views did not approach statistical significance (p = 0.15). Complications were higher with cephalocaudal flow outside local flow (p = 0.02). No serious complications occurred except for one pneumothorax, which could have been avoided. Immediate partial or complete pain relief was obtained in 88.5% (262/296) of the injections and 88.4% (199/225) of the examinations. CONCLUSION: Fluoroscopically guided thoracic foraminal nerve blocks are safe procedures and provide immediate partial or complete pain relief in a high percentage of patients.


Asunto(s)
Bloqueo Nervioso/efectos adversos , Radiografía Intervencional , Adolescente , Adulto , Anciano , Anciano de 80 o más Años , Distribución de Chi-Cuadrado , Femenino , Fluoroscopía , Humanos , Inyecciones Epidurales , Inyecciones Intraarticulares , Masculino , Persona de Mediana Edad , Dimensión del Dolor , Estudios Retrospectivos , Vértebras Torácicas , Resultado del Tratamiento
9.
Circ Res ; 102(11): 1406-15, 2008 Jun 06.
Artículo en Inglés | MEDLINE | ID: mdl-18451341

RESUMEN

Left ventricular hypertrophy (LVH) is associated with electric remodeling and increased arrhythmia risk, although the underlying mechanisms are poorly understood. In the experiments here, functional voltage-gated (Kv) and inwardly rectifying (Kir) K(+) channel remodeling was examined in a mouse model of pressure overload-induced LVH, produced by transverse aortic constriction (TAC). Action potential durations (APDs) at 90% repolarization in TAC LV myocytes and QT(c) intervals in TAC mice were prolonged. Mean whole-cell membrane capacitance (C(m)) was higher, and I(to,f), I(K,slow), I(ss), and I(K1) densities were lower in TAC, than in sham, LV myocytes. Although the primary determinant of the reduced current densities is the increase in C(m), I(K,slow) amplitudes were decreased and I(ss) amplitudes were increased in TAC LV cells. Further experiments revealed regional differences in the effects of LVH. Cellular hypertrophy and increased I(ss) amplitudes were more pronounced in TAC endocardial LV cells, whereas I(K,slow) amplitudes were selectively reduced in TAC epicardial LV cells. Consistent with the similarities in I(to,f) and I(K1) amplitudes, Kv4.2, Kv4.3, and KChIP2 (I(to,f)), as well as Kir2.1 and Kir2.2 (I(K1)), transcript and protein expression levels were similar in TAC and sham LV. Unexpectedly, expression of I(K,slow) channel subunits Kv1.5 and Kv2.1 was increased in TAC LV. Biochemical experiments also demonstrated that, although total protein was unaltered, cell surface expression of TASK1 was increased in TAC LV. Functional changes in repolarizing K(+) currents with LVH, therefore, result from distinct cellular (cardiomyocyte enlargement) and molecular (alterations in the numbers of functional channels) mechanisms.


Asunto(s)
Hipertrofia Ventricular Izquierda/metabolismo , Miocitos Cardíacos/metabolismo , Canales de Potasio/metabolismo , Potasio/metabolismo , Animales , Western Blotting , Separación Celular , Modelos Animales de Enfermedad , Ecocardiografía , Perfilación de la Expresión Génica , Hipertrofia Ventricular Izquierda/diagnóstico por imagen , Ratones , Técnicas de Placa-Clamp , Canales de Potasio/genética , ARN/metabolismo
10.
AJR Am J Roentgenol ; 194(3): 585-91, 2010 Mar.
Artículo en Inglés | MEDLINE | ID: mdl-20173132

RESUMEN

OBJECTIVE: The purpose of this study was to assess the accuracy of emphysema measurements obtained from systematic samples of evenly spaced CT images compared with measurements obtained from the entire scan. MATERIALS AND METHODS: Evenly spaced transverse sections from the CT studies of 136 heavy smokers who underwent screening for lung cancer in the National Lung Screening Trial and of 112 subjects who underwent imaging before lung volume reduction surgery were sampled retrospectively. The samples were acquired both by selection of specific numbers of evenly spaced images and by selection of images at specific distance intervals. The percentage of lung pixels with attenuation below specific thresholds was used as an emphysema index. The image sample error was determined as the difference in emphysema index between the image samples and the entire scan. RESULTS: The largest absolute image sample errors in the National Lung Screening Trial cohort with image sample sizes of five, 10, and 20 were 2.2, 0.8, and 0.5 index percentage points, respectively, at 1-mm section thickness (-960 HU threshold), and 2.6, 1.1, and 0.5 index percentage points at 5-mm section thickness (-930 HU threshold). The largest errors in the lung volume reduction surgery cohort for image sample sizes of five and 10 were 5.6 and 2.3 index percentage points at 8- to 10-mm section thickness (-900 HU threshold). Image sample errors were equivalent for the two sampling methods. CONCLUSION: Systematic sampling resulted in very small errors in emphysema quantification and may be useful for decreasing radiation exposure in clinical research studies of emphysema.


Asunto(s)
Enfisema Pulmonar/diagnóstico por imagen , Tomografía Computarizada por Rayos X/métodos , Anciano , Análisis de Varianza , Femenino , Humanos , Neoplasias Pulmonares/diagnóstico por imagen , Neoplasias Pulmonares/etiología , Masculino , Persona de Mediana Edad , Enfisema Pulmonar/etiología , Dosis de Radiación , Interpretación de Imagen Radiográfica Asistida por Computador , Estudios Retrospectivos , Índice de Severidad de la Enfermedad , Fumar/efectos adversos
11.
J Comput Assist Tomogr ; 34(5): 773-9, 2010.
Artículo en Inglés | MEDLINE | ID: mdl-20861785

RESUMEN

OBJECTIVE: To evaluate the use of inflation-fixed lung tissue for emphysema quantification with computed tomography (CT) and He magnetic resonance (MR) diffusion imaging. METHODS: Fourteen subjects representing a range of chronic obstructive pulmonary disease severity who underwent complete or lobar lung resection were studied. Computed tomographic measurements of lung attenuation and MR measurements of the hyperpolarized 3He apparent diffusion coefficient (ADC) in resected specimens fixed in inflation with heated formalin vapor were compared with measurements obtained before fixation. RESULTS: The mean (SD) CT emphysema indices were 56% (17%) before and 58% (19%) after fixation (P = 0.77; R = 0.76). Index differences correlated with differences in lung volume (R = 0.47). The mean (SD) 3He ADCs were 0.40 (0.15) cm/s before and 0.39 (0.14) cm/s after fixation (P = 0.03, R = 0.98). The CT emphysema index and the 3He ADC were correlated before (R = 0.89) and after fixation (R = 0.79). CONCLUSIONS: Concordance of CT and 3He MR imaging measurements in unfixed and inflation-fixed lungs supports the use of inflation-fixed lungs for quantitative imaging studies in emphysema.


Asunto(s)
Enfisema/diagnóstico , Imagen por Resonancia Magnética/métodos , Tomografía Computarizada por Rayos X/métodos , Anciano , Enfisema/diagnóstico por imagen , Enfisema/cirugía , Femenino , Helio , Humanos , Técnicas In Vitro , Masculino , Persona de Mediana Edad , Neumonectomía , Dosis de Radiación
12.
AJR Am J Roentgenol ; 192(3): 624-8, 2009 Mar.
Artículo en Inglés | MEDLINE | ID: mdl-19234256

RESUMEN

OBJECTIVE: The purpose of our study was to evaluate the performance of a computer-aided program that performs automated matching of pulmonary nodules imaged in three serial screening chest MDCT studies. MATERIALS AND METHODS: Forty subjects with pulmonary nodules depicted in three annual (T0, T1, T2) low-dose MDCT screening studies for lung cancer were selected from the National Lung Screening Trial database at a single institution. All CT images were reevaluated by two radiologists in consensus. One hundred forty-three nodules were identified and characterized by type (solid parenchymal, juxtavascular, juxtapleural, and ground-glass opacity) and size (< or = 4 mm, 4-6 mm, 6-8 mm, and > 8 mm). Using an automated program, nodules at T0 were matched to nodules at T1, and the same nodules at T1 were matched to nodules at T2. Associations between nodule matching rate (i.e., number of nodules matched by the program divided by the number of nodules determined to match by radiologists) and nodule type or size were analyzed. RESULTS: The combined matching rate of the nodules was 92.7% (T0 vs T1, 91.6%; T1 vs T2, 93.7%). By nodule type, the matching rate was 94.6% (parenchymal), 98.4% (juxtavascular), 85.8% (juxtapleural), and 100% (ground-glass opacity), with the rate significantly lower for juxtapleural nodules (p < 0.01). Matching rates were not significantly influenced by nodule size (p = 0.67). CONCLUSION: The automated matching rate for pulmonary nodules in screening MDCT scans was high (92.7%) and was not affected by the nodule size but was slightly lower with nodules at juxtapleural locations.


Asunto(s)
Neoplasias Pulmonares/diagnóstico por imagen , Reconocimiento de Normas Patrones Automatizadas/métodos , Interpretación de Imagen Radiográfica Asistida por Computador/métodos , Nódulo Pulmonar Solitario/diagnóstico por imagen , Tomografía Computarizada por Rayos X/métodos , Anciano , Distribución de Chi-Cuadrado , Femenino , Humanos , Masculino , Persona de Mediana Edad
13.
Radiology ; 246(1): 265-72, 2008 Jan.
Artículo en Inglés | MEDLINE | ID: mdl-18024436

RESUMEN

PURPOSE: To evaluate agreement among radiologists on the interpretation of pulmonary findings at low-dose computed tomographic (CT) screening examinations for lung cancer. MATERIALS AND METHODS: Institutional review board approval and informed consent were obtained. HIPAA guidelines were followed. Sixteen radiologists from the 10 National Lung Screening Trial screening centers of the National Cancer Institute's Lung Screening Study network reviewed image subsets from 135 baseline low-dose screening CT examinations in 135 trial participants (89 men, 46 women; mean age, 62.7 years +/- 5.4 [standard deviation]). Interpretations were classified into one of four of the following categories: noncalcified nodule 4 mm or larger in greatest transverse dimension (positive screening result); noncalcified nodule smaller than 4 mm in greatest transverse dimension (negative screening result); calcified, benign nodule (negative screening result); or no nodule (negative screening result). A recommendation for follow-up evaluation was obtained for each case. Interobserver agreement was evaluated by using the multirater kappa statistic and by using response frequencies and descriptive statistics. RESULTS: Multirater kappa values ranged from 0.58 (for agreement among all four classifications; 95% confidence interval: 0.55, 0.61) to 0.64 (for agreement on classification as a positive or negative screening result; 95% confidence interval: 0.62, 0.65). The average percentage of reader pairs in agreement on the screening result per case (percentage agreement) was 82%. There was wide variation in the total number of abnormalities detected and classified as pulmonary nodules, with differences of up to more than twofold among radiologists. For cases classified as positive, multirater kappa for follow-up recommendations was 0.35. CONCLUSION: Interobserver agreement was moderate to substantial; potential for considerable improvement exists. Clinical trial registration no. NCT00047385.


Asunto(s)
Neoplasias Pulmonares/diagnóstico por imagen , Tomografía Computarizada por Rayos X/estadística & datos numéricos , Femenino , Humanos , Masculino , Persona de Mediana Edad , Variaciones Dependientes del Observador
14.
Radiology ; 248(2): 655-61, 2008 Aug.
Artículo en Inglés | MEDLINE | ID: mdl-18641256

RESUMEN

PURPOSE: To evaluate the safety of hyperpolarized helium 3 ((3)He) magnetic resonance (MR) imaging. MATERIALS AND METHODS: Local institutional review board approval and informed consent were obtained. Physiologic monitoring data were obtained before, during, and after hyperpolarized (3)He MR imaging in 100 consecutive subjects (57 men, 43 women; mean age, 52 years +/- 14 [standard deviation]). The subjects inhaled 1-3 L of a gas mixture containing 300-500 mL (3)He and 0-2700 mL N(2) and held their breath for up to 15 seconds during MR imaging. Heart rate and rhythm and oxygen saturation of hemoglobin as measured by pulse oximetry (Spo(2)) were monitored continuously throughout each study. The effects of (3)He MR imaging on vital signs and Spo(2) and the relationship between pulmonary function, number of doses, and clinical classification (healthy volunteers, patients with asthma, heavy smokers, patients undergoing lung volume reduction surgery for severe emphysema, and patients with lung cancer) and the lowest observed Spo(2) were assessed. Any subjective symptoms were noted. RESULTS: Except for a small postimaging decrease in mean heart rate (from 78 beats per minute +/- 13 to 73 beats per minute +/- 11, P < .001), there was no effect on vital signs. A mean transient decrease in Spo(2) of 4% +/- 3 was observed during the first minute after gas inhalation (P < .001) in 77 subjects who inhaled a dose of 1 L for 10 seconds or less, reaching a nadir of less than 90% at least once in 20 subjects and of less than 85% in four subjects. There was no correlation between the lowest Spo(2) and pulmonary function parameters other than baseline Spo(2) (r = 0.36, P = .001). The lowest mean Spo(2) varied by 1% between the first and second and second and third doses (P < .001) and was unrelated to clinical classification (P = .40). Minor subjective symptoms were noted by 10 subjects. No serious adverse events occurred. CONCLUSION: Hyperpolarized (3)He MR imaging can be safely performed in healthy subjects, heavy smokers, and those with severe obstructive airflow limitation, although unpredictable transient desaturation suggests that potential subjects should be carefully screened for comorbidities.


Asunto(s)
Helio , Enfermedades Pulmonares/diagnóstico , Imagen por Resonancia Magnética/métodos , Monitoreo Fisiológico/métodos , Anciano , Análisis de Varianza , Femenino , Frecuencia Cardíaca/fisiología , Helio/efectos adversos , Humanos , Enfermedades Pulmonares/cirugía , Masculino , Persona de Mediana Edad , Oximetría , Seguridad
15.
J Vasc Interv Radiol ; 19(10): 1427-33, 2008 Oct.
Artículo en Inglés | MEDLINE | ID: mdl-18755600

RESUMEN

PURPOSE: The use of radioembolization of hepatic metastases with yttrium-90 ((90)Y) microspheres is increasing. The present report describes the outcomes in a cohort of patients with metastatic liver tumors treated with a resin-based microsphere agent. MATERIALS AND METHODS: Thirty patients with colon (n = 13), breast (n = 7), and other primary cancers (n = 10) were treated after the failure of first- and second-line therapy. Overall survival (OS), time to progression (TTP), and time to treatment failure (TTTF) were calculated from the first treatment. Response was measured according to Response Evaluation Criteria In Solid Tumors at interval follow-up imaging. RESULTS: Thirty patients underwent 56 infusions of (90)Y, and 18 remained alive at the end of the study. Fourteen patients (47%) had a partial response or stable disease. OS (604 vs 251 days), TTP (223 vs 87 days), and TTTF (363 vs 87 days) were all significantly longer for patients who had a partial response or stable disease (P < .05). Median OS, TTP, and TTTF for patients with colorectal carcinoma were 357, 112, and 107 days, respectively, versus 638, 118, and 363 days in patients with other metastatic sources. Median survival was not reached for patients with breast carcinoma, and the TTP and TTTF were each 282 days. One patient (3%) experienced grade 3 toxicity (gastrointestinal ulceration). CONCLUSIONS: (90)Y microsphere therapy produced promising survival rates compared with systemic salvage options, with minimal toxicity.


Asunto(s)
Neoplasias de la Mama/radioterapia , Neoplasias de la Mama/secundario , Neoplasias del Colon/radioterapia , Neoplasias del Colon/secundario , Neoplasias Hepáticas/radioterapia , Terapia Recuperativa/métodos , Radioisótopos de Itrio/uso terapéutico , Resinas Acrílicas/química , Adulto , Anciano , Anciano de 80 o más Años , Neoplasias de la Mama/diagnóstico por imagen , Neoplasias del Colon/diagnóstico por imagen , Portadores de Fármacos/química , Femenino , Humanos , Masculino , Persona de Mediana Edad , Proyectos Piloto , Radiografía , Radiofármacos/uso terapéutico , Estudios Retrospectivos , Resultado del Tratamiento
16.
AJR Am J Roentgenol ; 191(3): 808-13, 2008 Sep.
Artículo en Inglés | MEDLINE | ID: mdl-18716114

RESUMEN

OBJECTIVE: The purpose of this study was to evaluate the clinical significance of endoleaks detected on combined arterial and delayed contrast-enhanced follow-up CT examinations of patients who have undergone endovascular aneurysm repair of abdominal aortic aneurysm. MATERIALS AND METHODS: One hundred forty-four patients underwent periodic follow-up CT examinations 12-72 months after abdominal aortic aneurysm repair. The CT protocol consisted of an unenhanced scan and contrast-enhanced scans in the arterial and 90-second delayed phases. The endoleaks detected on dual-phase CT scans were evaluated in association with the outcome (therapeutic intervention or endoleak resolution). RESULTS: The 144 patients underwent 728 CT examinations with a mean follow-up period of 35.5 +/- 14.5 months. Fifty endoleaks were detected in 50 (34.7%) of the patients. Eight endoleaks were detected in the arterial phase only, eight in the delayed phase only, and 34 in both phases. Intervention was performed to manage 16 endoleaks detected in both phases. CT showed that three endoleaks were stable (two in the arterial phase only and one in both phases) and that 31 had resolved completely (six in the arterial phase only, eight in the delayed phase only, and 17 in both phases). This finding represents a higher frequency of resolution of endoleaks detected in one phase only than in both phases (Fisher's exact test, p = 0.006). CONCLUSION: Endoleaks detected only in the delayed phase of CT had resolved spontaneously without intervention. Therefore, we can consider eliminating the delayed phase of acquisition to minimize radiation exposure.


Asunto(s)
Aneurisma de la Aorta Abdominal/diagnóstico por imagen , Aneurisma de la Aorta Abdominal/cirugía , Procedimientos de Cirugía Plástica/efectos adversos , Hemorragia Posoperatoria/diagnóstico por imagen , Hemorragia Posoperatoria/etiología , Tomografía Computarizada por Rayos X/métodos , Procedimientos Quirúrgicos Vasculares/efectos adversos , Anciano , Anciano de 80 o más Años , Aneurisma de la Aorta Abdominal/complicaciones , Femenino , Estudios de Seguimiento , Humanos , Masculino , Persona de Mediana Edad , Pronóstico , Estudios Retrospectivos , Resultado del Tratamiento
17.
AJR Am J Roentgenol ; 190(3): 608-15, 2008 Mar.
Artículo en Inglés | MEDLINE | ID: mdl-18287429

RESUMEN

OBJECTIVE: We report the outcome of the care of 209 patients with hepatocellular carcinoma with a focus on relevant scoring systems for predicting overall survival and time to progression and on changes in presentation status and outcome from 1991 to 2006. MATERIALS AND METHODS: Hepatic arterial chemoembolization was performed on 209 patients in 375 sessions. Disease status was evaluated with the Child-Pugh, Okuda, Cancer of the Liver Italian Program, and American Joint Committee on Cancer (AJCC) systems. Changes in status at presentation from 1991 to 2006 and change in overall survival period and time to progression were analyzed. RESULTS: Median and mean overall survival periods for the entire group were 376 and 574 +/- 61 days. Median and mean times to progression were 267 and 409 +/- 54 days. Forty-nine patients underwent liver transplantation a median of 143 days after chemoembolization. The median and mean overall survival times among patients not undergoing transplantations were 466 and 574 +/- 61 days. Okuda score (p < 0.0001) and AJCC stage (p = 0.014) were the best predictors of overall survival and time to progression, respectively. Patients with disease with an Okuda I score and in AJCC stage I or II had median and mean overall survival periods of 667 and 992 +/- 176 days and times to progression of 378 and 589 +/- 110 days. Clinical status at presentation, overall survival period (p = 0.64), and time to progression (p = 0.44) were unchanged from 1991 to 2006. The 30-day mortality was 3.2%. CONCLUSION: Patients treated with hepatic arterial chemoembolization for HCC in Okuda score I and AJCC stage I or II have more durable survival than previously reported in a U.S. population.


Asunto(s)
Carcinoma Hepatocelular/mortalidad , Carcinoma Hepatocelular/terapia , Quimioembolización Terapéutica , Neoplasias Hepáticas/mortalidad , Neoplasias Hepáticas/terapia , Adulto , Anciano , Anciano de 80 o más Años , Carcinoma Hepatocelular/patología , Estudios de Cohortes , Supervivencia sin Enfermedad , Femenino , Humanos , Neoplasias Hepáticas/patología , Trasplante de Hígado , Masculino , Persona de Mediana Edad , Tasa de Supervivencia , Resultado del Tratamiento , Estados Unidos
18.
AJR Am J Roentgenol ; 190(1): 99-104, 2008 Jan.
Artículo en Inglés | MEDLINE | ID: mdl-18094299

RESUMEN

OBJECTIVE: Hepatic arterial chemoembolization is an accepted therapy for stage 4 melanoma with liver-dominant metastasis. However, the reports of outcomes are limited. We present our outcomes with hepatic arterial chemoembolization for metastasis of stage 4 melanoma. MATERIALS AND METHODS: Twenty patients with liver-dominant metastasis of ocular or cutaneous melanoma were treated with hepatic arterial chemoembolization. Overall survival and progression-free survival rates were calculated from the first treatment. Patients with intrahepatic tumor progression were treated with additional hepatic arterial chemoembolization. Both overall survival and progression-free survival were analyzed with the Kaplan-Meier method. Tumor pattern on angiography was characterized as either nodular or infiltrative on the basis of angiographic appearance. RESULTS: The 20 patients underwent 46 hepatic arterial chemoembolization sessions (mean, 2.4 sessions; range, 1-5). The mean and median overall survival times were 334 +/- 71 and 271 days, respectively. There were no deaths within 30 days of treatment. Thirteen of the 20 patients had progression of disease. The mean and median progression-free survival times for these patients were 231 +/- 42 and 185 days, respectively. Patients with lesions that had a nodular angiographic appearance had longer progression-free survival than patients with lesions that had an infiltrative appearance (mean progression-free survival time, 249 vs 63 days). Patients with lesions that had a nodular angiographic appearance also survived significantly longer than those with lesions that had an infiltrative angiographic pattern (mean overall survival time, 621 vs 114 days; p = 0.0002). CONCLUSION: Hepatic arterial chemoembolization for liver-dominant metastasis of stage 4 melanoma is a safe treatment that results in longer survival than has occurred among historical controls. Patients with lesions that have a nodular tumor appearance on angiography survive significantly longer than patients with lesions that have an infiltrative appearance on angiography.


Asunto(s)
Protocolos de Quimioterapia Combinada Antineoplásica/uso terapéutico , Quimioembolización Terapéutica/métodos , Arteria Hepática/diagnóstico por imagen , Neoplasias Hepáticas/secundario , Neoplasias Hepáticas/terapia , Melanoma/secundario , Melanoma/terapia , Adulto , Anciano , Anciano de 80 o más Años , Angiografía , Supervivencia sin Enfermedad , Neoplasias del Ojo/patología , Femenino , Humanos , Neoplasias Hepáticas/mortalidad , Masculino , Melanoma/mortalidad , Melanoma/patología , Persona de Mediana Edad , Estadificación de Neoplasias , Neoplasias Cutáneas/patología , Tasa de Supervivencia , Resultado del Tratamiento
19.
J Gastroenterol Hepatol ; 23(10): 1520-7, 2008 Oct.
Artículo en Inglés | MEDLINE | ID: mdl-18713303

RESUMEN

BACKGROUND AND AIM: To compare quadruple-phase multidetector computed tomography (MDCT) and magnetic resonance imaging (MRI) for the assessment of focal and diffuse liver disease. METHODS: Quadruple-phase contrast-enhanced MDCT and MRI of 37 consecutive patients were retrospectively reviewed by two readers (R1 and R2). In patients with focal liver lesions, the gold standard was histopathology (n = 17) and/or long-term (>6 months) follow-up imaging (n = 27) or transarterial chemoembolization (n = 1). Diffuse liver disease was confirmed by histopathology in all patients, when present. RESULTS: Both readers identified 60 focal liver lesions on MDCT and 56 focal liver lesions on MRI. Gold standard diagnoses revealed 48 focal liver lesions in 25 patients. Diagnosis of malignant liver lesions revealed a sensitivity of 88% (R1) and 91% (R2) for MRI; 63% (R1) and 66% (R2) for MDCT; and a specificity of 75% (R1) and 79% (R2) for MRI; 50% (R1) and 64% (R2) for MDCT. MRI was superior to MDCT for the diagnosis of malignant focal liver lesions, when the mean areas under the alternative free-response receiver operating characteristic curves (A(Z)) were compared (MRI = 0.93 vs CT = 0.69), (P < 0.00001). Thirty-three patients had histopathologically confirmed diffuse liver disease. Overall diagnosis of diffuse liver disease revealed a sensitivity of 88% (R1) and 92% (R2) for MRI; 75% (R1) and 74% (R2) for MDCT; and a specificity of 100% for both modalities by both readers. CONCLUSIONS: MRI is superior for the assessment of malignant focal liver lesions and diffuse liver disease compared to quadruple-phase MDCT, and can be considered as primary diagnostic imaging modality for liver imaging.


Asunto(s)
Hepatopatías/diagnóstico por imagen , Hepatopatías/patología , Imagen por Resonancia Magnética , Tomografía Computarizada por Rayos X , Adulto , Anciano , Femenino , Humanos , Masculino , Persona de Mediana Edad , Variaciones Dependientes del Observador , Valor Predictivo de las Pruebas , Curva ROC , Reproducibilidad de los Resultados , Estudios Retrospectivos , Sensibilidad y Especificidad
20.
Acad Radiol ; 25(3): 317-327, 2018 03.
Artículo en Inglés | MEDLINE | ID: mdl-29199057

RESUMEN

RATIONALE AND OBJECTIVES: Little is known about the frequency and risk factors of hepatic steatosis in the tertiary care setting. Such knowledge is essential to clinicians making decisions about testing for this condition. Thus, our aim was to describe the epidemiology of hepatic steatosis, as captured by magnetic resonance imaging (MRI), at a tertiary care center. MATERIALS AND METHODS: A near-consecutive cohort of 1006 adult patients underwent standard-of-care liver MRIs. Images were retrospectively processed to derive proton density fat fraction (PDFF) maps. Data from three spatially distinct regions of interest (ROIs) were aggregated to derive overall hepatic PDFF values. Demographic, anthropometric, clinical, and laboratory variables were included in a multivariate analysis to determine predictors of hepatic steatosis grades (based on established PDFF cutoffs). Hepatic steatosis grades derived from single vs aggregated ROIs were compared. RESULTS: Hepatic steatosis was observed in 25% of patients (19% grade 1; 3% grade 2; 3% grade 3). Controlling for all other variables, the odds of hepatic steatosis increased by 7%-9% (P <.001) for each whole point increase in body mass index (BMI), whereas elevated serum bilirubin was associated with lower odds of hepatic steatosis (P = .002). Race, diabetes mellitus, dyslipidemia, and metabolic syndrome were not independently predictive of hepatic steatosis when controlling for other variables (eg, BMI). Employing single ROIs (rather than three aggregated ROIs) resulted in incorrect steatosis grading in up to 8.0% of patients. CONCLUSION: Many adult patients undergoing liver MRI at a tertiary care center have hepatic steatosis, with larger BMIs as the only independent predictor of higher grades. This information can be used by clinicians at such centers to make evidence-based decisions about when to test for hepatic steatosis in their patients.


Asunto(s)
Hígado Graso/diagnóstico por imagen , Hígado Graso/epidemiología , Índice de Masa Corporal , Femenino , Humanos , Pruebas de Función Hepática , Imagen por Resonancia Magnética , Masculino , Persona de Mediana Edad , Análisis Multivariante , Estudios Retrospectivos , Factores de Riesgo , Centros de Atención Terciaria
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA