Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 8 de 8
Filtrar
1.
Echocardiography ; 27(8): 946-53, 2010 Sep.
Artículo en Inglés | MEDLINE | ID: mdl-20849482

RESUMEN

BACKGROUND: There are few data on echocardiographic indexes incorporating peak mitral inflow velocity (E), left atrial volume index (LAVi), and pulmonary artery pressure (PAP) for estimation of left ventricular (LV) filling pressure in patients with preserved LV ejection fraction (EF ≥ 50%). METHODS: Patients underwent echocardiography ≤20 minutes of cardiac catheterization. Echocardiographic variables were compared to invasively measured LV end-diastolic pressure (LVEDP). RESULTS: Of the 122 patients, 67 (55%) were women, the mean age was 55 ± 9 years, the mean left ventricular ejection fraction (LVEF) was 61 ± 6%, 107 (88%) were hypertensive, and 79 (65%) had significant coronary artery disease at catheterization. E/Ea correlated with LVEDP (R = 0.68, P < 0.0001), compared to PAP (R = 0.53, P < 0.001), peak E velocity (R = 0.48, P < 0.001), and LAVi (R = 0.48, P < 0.001). E/Ea > 12 had 75% sensitivity and 78% specificity for LVEDP ≥ 20 mmHg (area under curve (AUC) = 0.79, P < 0.0001), compared with (PAP + LAVi)/2 > 30 (sensitivity = 72%, specificity = 80%, AUC = 0.84, P < 0.001) and (E + LAVi)/2 > 57 (sensitivity = 73% and specificity = 81%, AUC = 0.82, P < 0.001) (P = NS). E <60 cm/sec had 94% negative, and E>90 cm/sec had 96% positive, predictive value for LVEDP ≥ 20 mmHg. (E + LAVi)/2 added incrementally to E/Ea when E/Ea was in the gray zone. CONCLUSIONS: New, simple echocardiographic equations, (E + LAVi)/2 and (PAP + LAVi)/2, have comparable accuracy to E/Ea for LVEDP estimation in patients with cardiac disease and preserved LVEF, and (E + LAVi)/2 added incrementally to E/Ea alone when E/Ea was in the gray zone. Peak E velocity alone had high negative and positive predictive value for elevated LVEDP in this population. These simple echocardiographic variables could be used-in isolation or with E/Ea-in patients with cardiac disease and preserved LVEF for the diagnosis of diastolic heart failure.


Asunto(s)
Algoritmos , Determinación de la Presión Sanguínea , Ecocardiografía/métodos , Interpretación de Imagen Asistida por Computador/métodos , Volumen Sistólico , Disfunción Ventricular Izquierda/diagnóstico por imagen , Femenino , Humanos , Aumento de la Imagen/métodos , Masculino , Persona de Mediana Edad , Reproducibilidad de los Resultados , Sensibilidad y Especificidad
2.
Am J Cardiol ; 101(12): 1766-71, 2008 Jun 15.
Artículo en Inglés | MEDLINE | ID: mdl-18549856

RESUMEN

There is controversy regarding the nature of systolic function in patients with elevated filling pressure and preserved left ventricular (LV) ejection fraction. In this study, tissue Doppler variables and 2-dimensional echocardiographic systolic strain (SS) and systolic strain rate (SSr) were measured in patients who underwent cardiac catheterization to determine correlations with invasively measured LV end-diastolic pressure (LVEDP), dP/dt, and LV mass. Forty patients were studied. Their mean age was 55.9+/-9.9 years, and their mean LV ejection fraction was 59.8+/-5.2%. Tissue Doppler systolic annular velocity (5.4+/-1.1 vs 6.4+/-1.0 cm/s, p=0.04), SS (13.4+/-3.7% vs 18.8+/-2.3%, p <0.001), and SSr (0.73+/-0.17 vs 0.98+/-0.14 s(-1), p <0.001) were significantly lower in patients with LVEDP >20 mm Hg compared with those with LVEDP <20 mm Hg. Tissue Doppler systolic velocity, SSr, and SS were correlated with LV mass (R=0.58, R=0.57, and R=0.52, respectively, all p values <0.001) and with LVEDP (R=0.49, p=0.002; R=0.79, p<0.001; and R=0.70, p<0.001, respectively). However, dP/dt was not significantly different between patients with LVEDP >20 mm Hg and those with LVEDP <20 mm Hg (1,387+/-520 vs 1,495+/-594 mm Hg/s, respectively, p=0.55) and was not correlated with LV mass (R=0.18, p=0.25). The optimum cut-off values for LVEDP >20 mm Hg were SSr <0.85 s(-1) (area under the curve 0.88, p<0.001, positive predictive value 89%, negative predictive value 86%) and SS<16% (area under the curve 0.84, p=0.002, positive predictive value 88%, negative predictive value 79%). In conclusion, as opposed to invasively measured dP/dt, tissue Doppler systolic velocity and 2-dimensional echocardiographic SS and SSr are significantly depressed in patients with preserved LV ejection fraction and LVEDP >20 mm Hg, suggesting that systolic abnormalities are present in at least some of these patients. These differences are likely because invasively measured dP/dt and these echocardiographic variables measure different systolic properties in patients with preserved LV ejection fraction.


Asunto(s)
Ecocardiografía Doppler/métodos , Insuficiencia Cardíaca Sistólica/diagnóstico por imagen , Contracción Miocárdica/fisiología , Volumen Sistólico/fisiología , Función Ventricular Izquierda/fisiología , Presión Ventricular/fisiología , Cateterismo Cardíaco , Diástole , Femenino , Estudios de Seguimiento , Insuficiencia Cardíaca Sistólica/fisiopatología , Humanos , Masculino , Persona de Mediana Edad , Pronóstico , Reproducibilidad de los Resultados , Índice de Severidad de la Enfermedad , Sístole
3.
Am J Cardiol ; 101(10): 1504-9, 2008 May 15.
Artículo en Inglés | MEDLINE | ID: mdl-18471466

RESUMEN

Tissue Doppler indexes of left ventricular (LV) filling pressure are prone to angulation errors and tethering and are less reliable in patients with preserved LV ejection fraction and indeterminate early peak transmitral diastolic flow (E)/mitral early diastolic velocity (Ea) (8 or =8 had higher sensitivity and specificity (95% and 94%, respectively; area under the curve = 0.96, p <0.0001) than E/Ea > or =15 (sensitivity 81%, specificity 75%; area under the curve = 0.85, p <0.0001) for the prediction of LV pre-A pressure > or =15 mm Hg (p = 0.01 for comparison). In patients with LV ejection fraction > or =50% and 8 or =50% or indeterminate E/Ea, both E/Ds and E/10DSr (a ratio based on global DSR) were better predictors of LV filling pressure than E/Ea.


Asunto(s)
Ecocardiografía Doppler/métodos , Contracción Miocárdica/fisiología , Disfunción Ventricular Izquierda/fisiopatología , Presión Ventricular/fisiología , Diástole , Femenino , Estudios de Seguimiento , Humanos , Masculino , Persona de Mediana Edad , Pronóstico , Sensibilidad y Especificidad , Índice de Severidad de la Enfermedad , Volumen Sistólico/fisiología , Disfunción Ventricular Izquierda/diagnóstico por imagen
4.
Am J Cardiol ; 102(4): 401-3, 2008 Aug 15.
Artículo en Inglés | MEDLINE | ID: mdl-18678295

RESUMEN

Adequate antiplatelet therapy is paramount for good clinical outcomes in patients undergoing percutaneous coronary intervention (PCI). The purpose of this study was to determine whether a high-dose regimen of clopidogrel in patients undergoing PCI is superior to standard dosing. A total of 119 patients undergoing PCI were blindly randomized in 2:1 fashion to receive clopidogrel loading 600 mg on the table immediately before PCI and 75 mg 2 times/day for 1 month (high-dose group) versus standard dosing (300 mg loading and 75 mg/day; low-dose group). Platelet aggregation was measured using light transmission aggregometry at baseline, 4 hours, and 30 days. The composite of cardiovascular death, myocardial infarction, and target vessel revascularization was studied at 30 days in addition to major and minor bleeding. Baseline characteristics and baseline platelet aggregation were similar in the 2 groups. Percent inhibitions of platelet activity were 41% and 27% in the high-dose group versus 19% and 10% in the low-dose group at 4 hours and 30 days (p = 0.046 and 0.047, respectively). Composite clinical end points were 10.3% in the high-dose group and 23.8% in the low-dose group (p = 0.04). No difference was noted in major or minor bleeding. In conclusion, a higher loading and maintenance dose of clopidogrel in patients undergoing PCI results in superior platelet inhibition and decreased cardiovascular events without increasing bleeding complications.


Asunto(s)
Angioplastia Coronaria con Balón , Plaquetas/efectos de los fármacos , Enfermedad de la Arteria Coronaria/tratamiento farmacológico , Stents Liberadores de Fármacos , Inhibidores de Agregación Plaquetaria/uso terapéutico , Ticlopidina/análogos & derivados , Clopidogrel , Enfermedad de la Arteria Coronaria/terapia , Esquema de Medicación , Femenino , Humanos , Masculino , Persona de Mediana Edad , Inhibidores de Agregación Plaquetaria/administración & dosificación , Estudios Prospectivos , Método Simple Ciego , Ticlopidina/administración & dosificación , Ticlopidina/uso terapéutico , Resultado del Tratamiento
5.
Eur J Echocardiogr ; 9(1): 156-7, 2008 Jan.
Artículo en Inglés | MEDLINE | ID: mdl-17602876

RESUMEN

A 62-year-old woman with a history of heart failure, hypertension and stroke presented to hospital with dyspnea. Transthoracic echocardiography revealed significant left ventricular dysfunction; with contrast-enhanced 2- and 3-dimensional echocardiography, extensive hypetrabeculation of the left ventricular myocardium was visualized, leading to a diagnosis of noncompaction cardiomyopathy. Apical thrombi were excluded with contrast imaging; however, the patient was systemically anticoagulated owing to the presence of noncompaction cardiomyopathy in the setting of prior stroke. This case report demonstrates remarkable imaging of the left ventricular myocardium achieved with contrast-enhanced 3-dimensional echocardiography in the setting of noncompaction cardiomyopathy.


Asunto(s)
Cardiomiopatías/diagnóstico por imagen , Insuficiencia Cardíaca/diagnóstico por imagen , Ventrículos Cardíacos/diagnóstico por imagen , Disfunción Ventricular Izquierda/diagnóstico por imagen , Ecocardiografía , Ecocardiografía Tridimensional , Femenino , Humanos , Persona de Mediana Edad , Miocardio
6.
J Am Coll Cardiol ; 45(1): 19-24, 2005 Jan 04.
Artículo en Inglés | MEDLINE | ID: mdl-15629367

RESUMEN

OBJECTIVES: The purpose of this study is to determine whether there is clinical significance to elevated troponin I in patients with suspected acute coronary syndromes (ACS) with non-critical angiographic coronary stenosis. BACKGROUND: Elevation of troponin in patients admitted with ACS symptoms with non-critical coronary artery disease (CAD) may result from coronary atherothrombosis not evident using standard angiography or from other ischemic and non-ischemic causes that may confer increased risk for future events. METHODS: Patients with ACS enrolled in the Treat Angina With Aggrastat and Determine Cost of Therapy With Invasive or Conservative Strategy-Thrombolysis In Myocardial Infarction (TACTICS-TIMI)-18 were included. Of 2,220 patients enrolled in the trial, 895 were eligible. Patients were divided into four groups according to troponin status on admission and presence of significant angiographic stenosis. Baseline brain natriuretic peptide (BNP) and C-reactive protein (CRP) were obtained on all patients. RESULTS: The median troponin I levels were 0.71 ng/ml in patients with CAD compared with 0.02 ng/ml in patients without CAD (p <0.0001). Troponin-positive patients with or without angiographic CAD had higher CRP and BNP levels compared with troponin-negative patients (p <0.01 for both). The rates of death or reinfarction at six months were 0% in troponin-negative patients with no CAD, 3.1% in troponin-positive patients with no CAD, 5.8% in troponin-negative patients with CAD, and 8.6% in troponin-positive patients with CAD (p=0.012). CONCLUSIONS: Elevated troponin in ACS is associated with a higher risk for death or reinfarction, even among patients who do not have significant angiographic CAD. The mechanisms conferring this adverse prognosis merit further study.


Asunto(s)
Angina Inestable/sangre , Infarto del Miocardio/sangre , Troponina I/sangre , Angina Inestable/mortalidad , Proteína C-Reactiva/análisis , Estenosis Coronaria/sangre , Humanos , Infarto del Miocardio/mortalidad , Péptido Natriurético Encefálico/sangre , Pronóstico , Ensayos Clínicos Controlados Aleatorios como Asunto , Estudios Retrospectivos , Análisis de Supervivencia , Síndrome
7.
J Am Soc Echocardiogr ; 23(2): 156-61, 2010 Feb.
Artículo en Inglés | MEDLINE | ID: mdl-20152696

RESUMEN

BACKGROUND: There are few data on adding left atrial volume index (LAVi) or pulmonary artery systolic pressure (PAP) to the ratio of early mitral inflow to mitral annular velocity (E/e') for the estimation of left ventricular (LV) filling pressure in patients with preserved LV ejection fractions (LVEFs) (>50%). METHODS: Patients underwent echocardiography within 20 minutes of cardiac catheterization. Echocardiographic variables were compared with invasively measured LV preatrial contraction pressure (pre-A). RESULTS: Of the 122 patients studied (mean age, 55 +/- 9 years; mean LVEF, 61 +/- 6%), 67 (55%) were women, 108 (88%) had hypertension, and 79 (65%) had significant coronary artery disease at catheterization. E/e' was significantly correlated with pre-A (R = 0.63, P < .0001) compared with LAVi (R = 0.49, P < .001) and PAP (R = 0.48, P < .001). E/e' > 13 had sensitivity of 70% and specificity of 93% (area under the curve [AUC], 0.82; P < .0001), LAVi > 31 mL/m2 had sensitivity of 78% and specificity of 76% (AUC, 0.80, P < .001), and PAP > 28 mm Hg had sensitivity of 80% and specificity of 64% for pre-A > 15 mm Hg (AUC, 0.77, P < .001). Adding LAVi >31 mL/m2 for E/e' = 8 to 13 significantly increased the accuracy of E/e' > 13 alone (sensitivity, 87%; specificity, 88%; AUC, 0.89; P = .01 for comparison). However, adding PAP > 28 mm Hg for E/e' = 8 to 13 did not significantly increase the accuracy of E/e' > 13 alone (AUC, 0.82; sensitivity, 82%; specificity, 72%; P = NS for comparison). CONCLUSIONS: In patients with preserved LVEFs, adding LAVi > 31 mL/m2 to E/e' (when E/e' was in the gray zone, but not when E/e' was >13) significantly increased the accuracy of E/e' alone for the estimation of LV filling pressure. These data support the notion of using several, rather than any single, Doppler echocardiographic parameter for the accurate assessment of LV diastolic function.


Asunto(s)
Presión Sanguínea , Ecocardiografía/métodos , Interpretación de Imagen Asistida por Computador/métodos , Volumen Sistólico , Disfunción Ventricular Izquierda/diagnóstico por imagen , Femenino , Humanos , Masculino , Persona de Mediana Edad , Reproducibilidad de los Resultados , Sensibilidad y Especificidad
8.
J Am Soc Echocardiogr ; 22(3): 284-9, 2009 Mar.
Artículo en Inglés | MEDLINE | ID: mdl-19168324

RESUMEN

BACKGROUND: There are a paucity of data comparing spectral and color tissue Doppler (TD) with non-Doppler, speckle-based myocardial velocities, and it is unknown how early transmitral diastolic velocity/mitral annular velocity (E/Ea) calculated using speckle velocities compares with TD-derived E/Ea. METHODS: We measured systolic (Sa), Ea, and late diastolic (Aa) myocardial velocities using these 3 methods and compared calculated E/Ea with invasively measured left ventricular (LV) hemodynamics. Consecutive patients referred for cardiac catheterization were imaged, and LV pre-A contraction pressure was measured by retrograde aortic cardiac catheterization. RESULTS: Fifty patients (22 women, 44%) were studied with a mean age of 54 +/- 10 years and a mean LV ejection fraction of 48% +/- 19%. Speckle and color TD Sa, Ea, and Aa were significantly lower than spectral TD velocities, resulting in higher E/Ea values compared with spectral TD E/Ea. Spectral TD E/Ea (R = 0.65, P < .001), color TD E/Ea (R = 0.69, P < .001), and speckle E/Ea (R = 0.76, P < .001) all correlated with LV pre-A pressure. Different cutoff values were needed for spectral TD, color TD, and speckle E/Ea to predict LV pre-A pressure >or= 15 mm Hg; spectral E/Ea > 14 (area under the curve [AUC] = 0.87, P < .001, sensitivity = 83%, specificity = 77%), color E/Ea > 16 (AUC = 0.89, P < .0001, sensitivity = 79%, specificity = 81%), and speckle E/Ea > 18 (AUC = 0.87, P < .0001, sensitivity = 88%, specificity = 74%; P = not significant for comparisons between the groups). CONCLUSION: Spectral TD, color TD, and speckle imaging measure different velocities, and consequently different cutoff values are needed for E/Ea to predict invasively measured LV filling pressure.


Asunto(s)
Algoritmos , Ecocardiografía Doppler en Color/métodos , Diagnóstico por Imagen de Elasticidad/métodos , Interpretación de Imagen Asistida por Computador/métodos , Volumen Sistólico , Disfunción Ventricular Izquierda/diagnóstico por imagen , Femenino , Humanos , Aumento de la Imagen/métodos , Masculino , Persona de Mediana Edad , Reproducibilidad de los Resultados , Sensibilidad y Especificidad
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA